1 |
Desenvolvimento de métodos analíticos empregando a espectrometria de absorção atômica sequencial rápida com atomização em chama / Development of analytical methods employing fast sequential atomic absorption spectrometry with flame atomizationMiranda, Kelber dos Anjos de 19 February 2012 (has links)
Made available in DSpace on 2016-06-02T20:34:36Z (GMT). No. of bitstreams: 1
4531.pdf: 708473 bytes, checksum: fa2ea780712d3ffbd332ab95fd4c9dff (MD5)
Previous issue date: 2012-02-19 / Universidade Federal de Sao Carlos / The aim of this PhD thesis was to develop analytical methods employing fast sequential flame atomic absorption spectrometry (FS-FAAS). In the first part of this study, a fast and simple method is proposed for the determination of Cu in sugar cane spirits employing FS-FAAS and the internal standard technique. First, Ag, Bi, Co and Ni were evaluated as internal standards to correct transport interferences caused by the presence of ethanol. The results demonstrated that Ag at a concentration of 2 mg L−1 was effective as internal standard. In the second part of this study, a novel analytical method which consists of a combination of hydride generation and FS-FAAS is proposed. The method developed was employed for the sequential determination of As and Sb at sub-μg L-1 levels in bottled mineral waters. An enhancement in the analytical throughput was obtained when compared with the traditional monoelement HGAAS with a quartz tube atomizer. In the last part of the study, the combination of thermospray flame furnace atomic absorption spectrometry (TS-FF-AAS) and FS-FAAS for the sequential determination of Cd, Cu, Pb and Zn was proposed and a significant improvement in the analytical throughput of TS-FFAAS was obtained. Then, an analytical method for the sequential determination of Cd, Cu and Pb in slurries of biological samples by TS-FF-AAS was developed. / Esta tese de doutorado teve como objetivo o desenvolvimento de métodos analíticos empregando a espectrometria de absorção atômica sequencial rápida com atomização em chama (FS-FAAS). Na primeira parte do estudo, avaliou-se o uso da padronização interna em FS-FAAS através da determinação direta de Cu em amostras de aguardente de cana. Neste caso, Ag, Bi, Co e Ni foram avaliados como padrões internos para a correção do efeito de transporte causado pela presença de etanol na matriz. Os resultados demostraram que Ag na concentração de 2 mg L−1 foi eficaz como padrão interno na determinação direta de Cu em amostras de aguardente por FS-FAAS. Na segunda parte do estudo, avaliou-se o potencial do acoplamento entre a geração de hidretos (HG) e a FS-FAAS para a determinação sequencial de As e Sb em amostras de água mineral. Os resultados revelaram que a HG no modo multielementar proporcionou um aumento considerável da frequência analítica, redução do consumo de reagentes e diminuição da geração de resíduos em relação à HG no modo monoelementar. Na última parte do estudo, avaliou-se o potencial da união da espectrometria de absorção atômica com forno tubular na chama e aerossol térmico (TS-FF-AAS) com a FS-FAAS para a determinação sequencial de Cd, Cu, Pb e Zn. Os resultados evidenciaram o aumento da frequência analítica proporcionada pela TS-FF-AAS no modo multielementar em relação ao modo monoelementar. Em seguida, amostras biológicas foram prédigeridas e introduzidas na forma de suspensões no sistema TS-FF-AAS para a determinação sequencial de Cd, Cu, Pb e Zn.
|
2 |
Desenvolvimento de metodologia analítica para a determinação de arsênio em fertilizantes minerais / Development of analytical methods for determination of as in samples of minerals fertilizersMachado, Raquel Cardoso 20 February 2014 (has links)
Made available in DSpace on 2016-06-02T20:36:52Z (GMT). No. of bitstreams: 1
6050.pdf: 1441595 bytes, checksum: fd3af131af9f35653c7f61c362e4022a (MD5)
Previous issue date: 2014-02-20 / Financiadora de Estudos e Projetos / Analytical method for the determination of As in samples of minerals fertilizers by Hydride Generation Flame Atomic Absorption Spectroscopy (HG AAS) was developed. First of all a study to check the effect of the concomitants on the analytical signal of the As was performed, and the presence of Cu and Ni, in the ratio analyte:interferent (1:10) and (1:1); Fe and Mg (1:500); Ca and Mn (1:50); Zn, Cr and Pb (1:5); and B (1:40) not interfere in the As analytical signal, with recovery within 97 and 103% in samples with the addition of these concomitants. Two procedures of digestion were optimized: using digester block with low pressure vials of PFA (perfluoroalkoxy) closed and cavity microwave oven. A full factorial design was used to investigate the variables (1) type of reagent (HNO3 7 mol L-1 + H2O2 (30% w w-1) or aqua regia), (2) time (only for digestion block) and (3) concentration of the reagents (diluted 1:1 or not). As answer the recovery of As, normalized between 0 and 1 using the function of desirability was utilized. The optimized conditions by using digester block with PFA vials were: HNO3 7 mol L-1 + H2O2 (30% w w-1), 4 h of digestion and diluted reagent 1:1. The best conditions for microwave digestion assisted were the same, with total time of 50 min. Concentrations of As also were determination by inductively coupled plasma optical emission spectrometry (ICP OES) to results comparison with the use of three different minerals fertilizers that were prepared from the use of the two optimized digestion procedures. The paired t-test was applied to compare the results and no statically difference were observed at 95% of confidence between the amount of As obtained in the sample preparation procedures, though differences between the techniques were observed. Therefore the digestion block can be considered an alternative procedure of minerals fertilizers sample preparation. The detection limit of the method defined as 3 s of background variation was 0.27 μg L-1, and 0.89 μg L-1 as limit of quantification. RSD for As determination at the concentration of 1 μg L-1 was 7.56%; for 7 μg L-1 was 2,28%; and for a solution of 20 μg L-1was 1.54%. Linear range was from1.0 up to 40.0 μg L-1, and 0.9926 of linearity were obtained. To accuracy evaluation, certificate reference material (NIST 695) was used, with recovery of 92 %. The method was successfully applied to the determination of As in nine samples of minerals fertilizers. / Método analítico para determinação de As em fertilizantes minerais por espectrometria de absorção atômica com chama e geração de hidretos (HG AAS) foi desenvolvido. Primeiramente realizou-se um estudo para verificar o efeito dos concomitantes sobre o sinal analítico do As e observou-se que a presença de Cu e Ni, nas razões analito:interferente (1:10) e (1:1), além de Fe e Mg (1:500), Ca e Mn (1:50), Zn, Cr e Pb (1:5) e B (1:40) não interferem na obtenção do sinal analítico para As, sendo obtidos percentuais de recuperação para as soluções contendo esses concomitantes entre 97 e 103%. Dois procedimentos de digestão estudados foram otimizados: empregando um bloco digestor com tubos de PFA (polifluoralcoxi) rosqueáveis e de baixa pressão e um forno com radiação micro-ondas. Planejamento fatorial completo foi utilizado para investigar as variáveis (1) tipo de reagente (HNO3 7 mol L-1 + H2O2 (30% m m-1) ou água régia), (2) tempo (apenas para a digestão em bloco) e (3) concentração dos reagentes (reagentes diluídos 1:1 ou não), considerando massa de amostra 200 mg. Como resposta foram utilizadas as recuperações de As normalizadas entre 0 e 1 por meio da função de desejabilidade. As melhores condições para a decomposição empregando bloco digestor com tubos de PFA foram as seguintes: mistura de HNO3 7,0 mol L-1 + H2O2 (30% m m-1), 4 horas de digestão e diluição 1:1 dos reagentes. As melhores condições para decomposição das amostras empregando forno micro-ondas foram idênticas às estabelecidas no procedimento anterior, porém com tempo total de digestão igual a 50 min. Concentrações de As também foram determinadas por espectrometria de emissão óptica com plasma acoplado indutivamente (ICP OES) para comparação dos resultados, sendo utilizadas três amostras de fertilizantes minerais com características distintas, preparadas a partir do emprego dos dois procedimentos de digestão já otimizados. Teste t pareado foi aplicado para comparação entre os resultados. Ao nível de 95 % de confiança não foram observadas diferenças significativas entre as concentrações de As obtidas nos procedimentos de preparo, embora diferenças entre as técnicas tenham sido observadas, sendo a digestão empregando bloco digestor com tubos de PFA considerada alternativa para o preparo de amostras de fertilizantes minerais. Os seguintes parâmetros de desempenho foram obtidos: 0,27 e 0,89 μg L-1 respectivamente para os limites de detecção e de quantificação, repetibilidade (RSD) (7,56% para solução de 1 μg L-1; 2,28% para a solução de 7 μg L-1; e 1,54% para a solução de 20 μg L-1). Faixa linear entre 1,0 e 40,0 μg L-1), com R2 de 0,9926 foi observado. Para avaliação da exatidão, empregou-se material de referência certificado (NIST 695), sendo obtido 92% de recuperação. O método foi aplicado para determinação de As em 9 amostras de fertilizantes minerais.
|
Page generated in 0.0135 seconds