• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 7
  • 4
  • 1
  • 1
  • Tagged with
  • 13
  • 8
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Fondements de l'homéopathie à partir de la philosophie de Hegel / Tackling homeopathy's grounds at the light of Hegelian philosophy

Bardy, Stéphanie 25 March 2019 (has links)
Ce travail est le résultat d’un essai d’extraction d’un possible fondement logique à la médecine homéopathique.Aucune véritable théorie sur l’homéopathie n’a donc vu le jour lors de sa découverte par S. Hahnemann et c'est cette lacune que nous nous proposons ici d'interroger.Dans cette recherche, nous avons donc essayé d’identifier un possible fondement philosophique à même d’expliquer l’effectivité thérapeutique de la médecine homéopathique, en nous appuyant sur la philosophie hégélienne en raison de sa systématicité. Puisqu’il n’y a plus de substance (donc de principe actif) d’un point de vue moléculaire dans la plupart des médicaments homéopathiques, comment expliquer l’effectivité de cette substance ? Nous formulons ici et essayons de démontrer l’hypothèse selon laquelle il existerait une rationalité différente de celle sur laquelle repose l’allopathie. Une rationalité qui serait précisément à même de fonder logiquement l’effectivité thérapeutique de l’homéopathie.Trois questions ont guidé notre réflexion : - Comment concevoir la notion de substance homéopathique dans la philosophie de la Nature de Hegel ?- Comment élever le système de la santé à une postulation ontologique ? - Comment rattacher la pathologie à une logique de la liberté ? Pour notre démonstration, nous avons, dans notre première partie, ouvert sur l’histoire de la philosophie, qui nous conduit à penser la substance chez Hegel. Nous avons poursuivi, dans un deuxième temps, notre réflexion par une analyse de la Science de la logique telle que Hegel la développe dans l’Encyclopédie, de manière à poser les bases d’une proposition de rationalité pour l’homéopathie. Proposition que nous avons développée dans la troisième partie, dans laquelle nous posons enfin la question de la liberté de l’individu face à la pathologie. / This work results from attempts at a possible unraveling of the logical grounds of homeopathic medicine. No genuine epistemology of homeopathy has been proposed by S. Hahnemann upon its discovery. Adressing such caveat has been the purpose of our work.To this aim, this research has been dedicated to the identification of a possible philosophical ground capable of explaining the effectiveness of homeopathy. This goal has been pursued considering GWF Hegel’s works as guiding principles and roadmaps because of the systematic rigor of this author’s theoretical productions. Since active molecules are deemed absent from most homeopathic preparations, how can one explain their therapeutic activity?Our hypothesis aimed at providing an answer to this question necessitates the introduction of another reasoning mode, not shaped by conventional pharmacology, i.e. differing from allopathy’s. Instead, we postulate that the Hegelian understanding of the active substance is precisely relevant in providing a logical basis for the clinical effectiveness of homeopathy, implicating three logically concatenated questions:- How can we conceptualize the status of the homeopathic substance in Hegel’s philosophy of nature?- How can we make the human health system catch up with ontological perspectives?- How can we associate the concept of pathology with the notion of freedom-structured logic at the patient level?Our demonstration is divided into three parts. The first section will consider how the history of philosophy allows one to gain access to the notion of the Hegelian substance. We then carry out an analysis of the Science of Logic as found in Hegel’s Encyclopedia in order to set the basis for a possible notion of rationality related to homeopathy, prior to more thoroughly unfolding its contents in the third part of this thesis. Hence, the third section of the document focuses on the implication of illness as a potential milestone relevant to our human quest for freedom.
12

Estudo comparativo de soluções ultra diluídas de LiCl: espectroscopia de impedância no intervalo de frequência entre 1kHz e 13MHz / Comparative studies of ultra-higt diluídas de LiCl: espectroscopy in the frequency range of 1KHz to 13MHz

Miranda, Adriana Ramos de 06 March 2008 (has links)
O objetivo principal deste trabalho, foi a caracterização física de soluções ultra diluídas de cloreto de lítio utilizando a técnica de espectroscopia de impedância, no intervalo de freqüência entre 1kHz e 13MHz. A caracterização destas soluções foi realizada, principalmente, através do estudo do comportamento da parte imaginária da impedância de soluções diluídas e dinamizadas, até concentrações de 10-30M. A comparação com a água foi realizada através do estudo de amostras de água (denominada água de referência) submetidas, rigorosamente, ao mesmo processo de diluição e dinamização pelo qual passaram as soluções, com as quais foram comparadas. Os resultados experimentais revelaram, também, que a técnica da espectroscopia de impedância constitui-se em uma boa ferramenta para a investigação da água. Um estudo detalhado sobre a temperatura de medição das soluções foi realizado e, no intervalo de freqüência explorado, o melhor protocolo de medição baseia-se em medidas feitas em uma temperatura próxima da temperatura ambiente, em uma sala climatizada. Os valores experimentais medidos da parte real e imaginária da impedância, em cada ponto de freqüência considerado, foram modelados através dos parâmetros de um circuito elétrico equivalente. Os resultados desta análise mostraram que os dados de impedância, obtidos neste trabalho para as soluções ultra diluídas e para água de referência, são modelados de forma excelente por um circuito composto de uma resistência r em série com um circuito RC (em paralelo). A resistência R, calculada através da modelagem pelo circuito equivalente, revelou-se o melhor parâmetro para caracterizar as soluções ultra diluídas de concentrações inferiores a 10-6 M, assim como as amostras de água estudadas. Diferenças efetivas foram encontradas entre as soluções ultra diluídas LiCl 15cH (correspondente a 15a centesimal hahnemanniana) e a água de referencia, e um comportamento não monotônico da impedância foi observado durante o processo de diluição e dinamização, quando as diluições 3 a 15cH foram medidas para um mesmo lote de amostras. / The impedance spectroscopy technique was applied to the physical characterization of ultra high dilutions of lithiun cloride, in the range 1kHz to 13MHz. This characterization was obtained, mainly, by investigating the behavior of the imaginary part of the impedance of diluted and dinamizated solutions, for concentrations down to 10-30M. The experimental results were compared to the ones obtained for water, which have been submitted to exactly the same process of dilution and dinamization. Preliminary tests were carried out in order to identify the best experimental conditions to be used, mainly in respect to choosing the samples\' temperature. In result, the best measuring protocol was observed to be the one in which the liquid samples were measured at room temperature, mantained practically constant by an air conditioning system. The experimental data related to the real and imaginary part of the impedance, for each frequency value, were modeled by adjusting the parameters of an equivalent electric circuit. The results of this analysis showed that the impedance values of the ultra high dilutions and of the water agree quite well with the modelling, when the circuit are composed by a resistance r in series with a RC circuit (in parallel). The resistence R, calculated through the modelling by the equivalent circuit, was the best parameter to characterize both the ultra high dilutions (concentration smaller than 10-6M) as well as the water. Clear differences were also observed when the ultra high dilutions of LiCl 15cH (corresponding to 15a centesimal dilution) were compared to the water. A non-monotonous behavior was obtained when solutions from 3 to 15cH (corresponding to the same lot of samples) were measured.
13

Estudo comparativo de soluções ultra diluídas de LiCl: espectroscopia de impedância no intervalo de frequência entre 1kHz e 13MHz / Comparative studies of ultra-higt diluídas de LiCl: espectroscopy in the frequency range of 1KHz to 13MHz

Adriana Ramos de Miranda 06 March 2008 (has links)
O objetivo principal deste trabalho, foi a caracterização física de soluções ultra diluídas de cloreto de lítio utilizando a técnica de espectroscopia de impedância, no intervalo de freqüência entre 1kHz e 13MHz. A caracterização destas soluções foi realizada, principalmente, através do estudo do comportamento da parte imaginária da impedância de soluções diluídas e dinamizadas, até concentrações de 10-30M. A comparação com a água foi realizada através do estudo de amostras de água (denominada água de referência) submetidas, rigorosamente, ao mesmo processo de diluição e dinamização pelo qual passaram as soluções, com as quais foram comparadas. Os resultados experimentais revelaram, também, que a técnica da espectroscopia de impedância constitui-se em uma boa ferramenta para a investigação da água. Um estudo detalhado sobre a temperatura de medição das soluções foi realizado e, no intervalo de freqüência explorado, o melhor protocolo de medição baseia-se em medidas feitas em uma temperatura próxima da temperatura ambiente, em uma sala climatizada. Os valores experimentais medidos da parte real e imaginária da impedância, em cada ponto de freqüência considerado, foram modelados através dos parâmetros de um circuito elétrico equivalente. Os resultados desta análise mostraram que os dados de impedância, obtidos neste trabalho para as soluções ultra diluídas e para água de referência, são modelados de forma excelente por um circuito composto de uma resistência r em série com um circuito RC (em paralelo). A resistência R, calculada através da modelagem pelo circuito equivalente, revelou-se o melhor parâmetro para caracterizar as soluções ultra diluídas de concentrações inferiores a 10-6 M, assim como as amostras de água estudadas. Diferenças efetivas foram encontradas entre as soluções ultra diluídas LiCl 15cH (correspondente a 15a centesimal hahnemanniana) e a água de referencia, e um comportamento não monotônico da impedância foi observado durante o processo de diluição e dinamização, quando as diluições 3 a 15cH foram medidas para um mesmo lote de amostras. / The impedance spectroscopy technique was applied to the physical characterization of ultra high dilutions of lithiun cloride, in the range 1kHz to 13MHz. This characterization was obtained, mainly, by investigating the behavior of the imaginary part of the impedance of diluted and dinamizated solutions, for concentrations down to 10-30M. The experimental results were compared to the ones obtained for water, which have been submitted to exactly the same process of dilution and dinamization. Preliminary tests were carried out in order to identify the best experimental conditions to be used, mainly in respect to choosing the samples\' temperature. In result, the best measuring protocol was observed to be the one in which the liquid samples were measured at room temperature, mantained practically constant by an air conditioning system. The experimental data related to the real and imaginary part of the impedance, for each frequency value, were modeled by adjusting the parameters of an equivalent electric circuit. The results of this analysis showed that the impedance values of the ultra high dilutions and of the water agree quite well with the modelling, when the circuit are composed by a resistance r in series with a RC circuit (in parallel). The resistence R, calculated through the modelling by the equivalent circuit, was the best parameter to characterize both the ultra high dilutions (concentration smaller than 10-6M) as well as the water. Clear differences were also observed when the ultra high dilutions of LiCl 15cH (corresponding to 15a centesimal dilution) were compared to the water. A non-monotonous behavior was obtained when solutions from 3 to 15cH (corresponding to the same lot of samples) were measured.

Page generated in 0.0464 seconds