Spelling suggestions: "subject:"halfwavelength"" "subject:"multiwavelength""
1 |
Behavior of polygonal semi-closed thin-walled cross-section : A study based on finite strip analysisJimmy, Adamo, Hamse, Abdi January 2017 (has links)
The acceptance and the use of cold-formed steel sections has significantly increased in recent years due to advantages such as consistency and accuracy of profile, ease of fabrication, high strength and stiffness to the lightness in the weight. For thin-walled columns, made by folding a plane plate into a section, it is possible that when they are subjected to compression loads they may buckle either locally, if the member is very short, or globally if the member is very long. In addition to local and global buckling, a thin-walled member of an open cross section may also show buckling involving a “distortion” of the cross section. Compared to local and global buckling, distortional buckling is not very familiar and has been discovered only in thin-walled members of open cross sections such as cold-formed steel section columns. The objective of this study is to investigate the behavior of polygonal semi-closed cross-section with pure compression. The study comprise to only elastic buckling and the methodology is consisted by using CUFSM analysis. In order to execute CUFSM of polygonal profiles, the scripts have created which match the Matlab script files (m-files) downloaded from CUFSM 4 open source. The distortional buckling mode is governing as a buckling failure, which occur and dominate in the cases where spring values are 100 kN or higher. However, the contrary result reveals by a decreasing of the spring values. The behavior of the cross-section is dependent on how the interaction of different buckling modes prevails at the corresponding critical half-wavelength. Considering the predomination of distortional buckling mode indicates that the most of polygonal cross-section do not behave as rigid, i.e. as whole cross-section. A reducing of distortional mode and increasing of local mode as well as global mode gives indication that the behavior of the cross-section has changed and turned significantly into more rigid and thus is expected to behave more as whole cross-section. The more spring values decrease, the higher global mode arises and dominates for the lower slenderness range. The critical half-wavelength for each profile illustrates the needed density between bolts on the longitudinal part of the member. In the interest of eliminating distortional buckling failure, due the fact that distortional buckling is unpredictable, the bolt-density should be lower than the corresponding half-wavelength for the profile where the distortional mode is predominating.
|
2 |
Dual-Band Quarter Wavelength and Half Wavelength Microstrip Transmission Line DesignImran, Md Asheque 05 1900 (has links)
The thesis represents the design for dual-band quarter wavelength and half wavelength microstrip transmission line. Chapter 2 proposed the design of a novel dual-band asymmetric pi-shaped short-circuited quarter wavelength microstrip transmission line working at frequencies 1GHz and 1.55 GHz for 50Ω transmission line and at frequencies 1GHz and 1.43GHz for 60Ω transmission line. Chapter 3 proposed the design of a novel dual-band quarter wavelength microstrip transmission line with asymmetrically allocated open stubs and short-circuited stubs working at frequencies 1GHz and 1.32GHz. Chapter 4 proposed the design of dual-band pi-shaped open stub half wavelength microstrip transmission line working at frequencies 1GHz and 2.07GHz. Numerical simulations are performed both in HyperLynx 3D EM and in circuit simulator ADS for all of the proposed designs to measure the return loss (S11) and insertion loss (S12) in dB and phase response for S12 in degree.
|
3 |
Transmissão de energia elétrica em meia-onda e em corrente contínua - análise técnico-econômica. / Half wave-length power transmission and HVDC power transmission - a technical and eponomical analysis.Santos, Milana Lima dos 19 March 2012 (has links)
Ao buscar alternativas para interligação entre importantes centros de geração de energia elétrica localizados no Norte do Brasil e centros consumidores no Nordeste e Sudeste, o setor elétrico brasileiro se depara com o desafio de transpor distâncias superiores a 2000 km. A alternativa em corrente contínua já é bastante utilizada, com desempenho satisfatório. Já a transmissão em meia-onda, ainda não utilizada comercialmente em país algum do mundo, é uma alternativa sugerida por alguns artigos como adequada a esse propósito. Este trabalho se propõe a apresentar uma metodologia de comparação econômica entre alternativas de transmissão e aplicá-la à comparação entre a meia-onda e a corrente contínua, utilizando um cenário muito próximo ao brasileiro. Para possibilitar esta comparação, são apresentados detalhes do funcionamento da linha de meia-onda, já que pouco foi publicado sobre o assunto. São mencionados alguns aspectos adversos de seu comportamento transitório e também são descritas etapas de definição de alternativas de transmissão a serem avaliadas. / In order to connect important power generation plants located in Northern region to the major load centers in the Northeast and Southeast parts of the country, the Brazilian electric sector should deal with the challenge of planning transmission systems to cover distances of more than 2000 km. The HVDC transmission alternative, which has shown satisfactory response and performance to also carry bulk power over long distances, is already used in many countries. Still, the half-wavelength power transmission line (HWLL), not yet commercially used in any country, is an alternative suggested by some papers as suitable for this purpose. Thus, the objective of this work is to present a methodology for the economic comparison amongst the transmission alternatives present today, to thereafter apply it to the HWLL and HVDC transmission technologies. To do so, a closest scenario to that of the Brazilian case will be used. In order to perform this comparison, some details of the HWLL operation are explored, since little was published on this subject. Also, some adverse aspects of the HWLL transient behavior as well as the steps for defining the transmission alternatives to be evaluated are presented.
|
4 |
Transmissão de energia elétrica em meia-onda e em corrente contínua - análise técnico-econômica. / Half wave-length power transmission and HVDC power transmission - a technical and eponomical analysis.Milana Lima dos Santos 19 March 2012 (has links)
Ao buscar alternativas para interligação entre importantes centros de geração de energia elétrica localizados no Norte do Brasil e centros consumidores no Nordeste e Sudeste, o setor elétrico brasileiro se depara com o desafio de transpor distâncias superiores a 2000 km. A alternativa em corrente contínua já é bastante utilizada, com desempenho satisfatório. Já a transmissão em meia-onda, ainda não utilizada comercialmente em país algum do mundo, é uma alternativa sugerida por alguns artigos como adequada a esse propósito. Este trabalho se propõe a apresentar uma metodologia de comparação econômica entre alternativas de transmissão e aplicá-la à comparação entre a meia-onda e a corrente contínua, utilizando um cenário muito próximo ao brasileiro. Para possibilitar esta comparação, são apresentados detalhes do funcionamento da linha de meia-onda, já que pouco foi publicado sobre o assunto. São mencionados alguns aspectos adversos de seu comportamento transitório e também são descritas etapas de definição de alternativas de transmissão a serem avaliadas. / In order to connect important power generation plants located in Northern region to the major load centers in the Northeast and Southeast parts of the country, the Brazilian electric sector should deal with the challenge of planning transmission systems to cover distances of more than 2000 km. The HVDC transmission alternative, which has shown satisfactory response and performance to also carry bulk power over long distances, is already used in many countries. Still, the half-wavelength power transmission line (HWLL), not yet commercially used in any country, is an alternative suggested by some papers as suitable for this purpose. Thus, the objective of this work is to present a methodology for the economic comparison amongst the transmission alternatives present today, to thereafter apply it to the HWLL and HVDC transmission technologies. To do so, a closest scenario to that of the Brazilian case will be used. In order to perform this comparison, some details of the HWLL operation are explored, since little was published on this subject. Also, some adverse aspects of the HWLL transient behavior as well as the steps for defining the transmission alternatives to be evaluated are presented.
|
Page generated in 0.0344 seconds