• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 37
  • 3
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 39
  • 39
  • 39
  • 27
  • 24
  • 19
  • 18
  • 17
  • 16
  • 16
  • 15
  • 14
  • 14
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Otimização multiobjetivo da compensação de potência reativa em redes de distribuição considerando restrições de distorção harmônica

AZEVEDO, Manoel Socorro Santos 14 November 2014 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2015-05-19T22:30:14Z No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Tese_OtimizacaoMultiobjetivoCompensacao.pdf: 1385522 bytes, checksum: f28192c0b6b8ec65f18eb07c8458c66f (MD5) / Approved for entry into archive by Ana Rosa Silva (arosa@ufpa.br) on 2015-05-20T14:36:25Z (GMT) No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Tese_OtimizacaoMultiobjetivoCompensacao.pdf: 1385522 bytes, checksum: f28192c0b6b8ec65f18eb07c8458c66f (MD5) / Made available in DSpace on 2015-05-20T14:36:25Z (GMT). No. of bitstreams: 2 license_rdf: 22974 bytes, checksum: 99c771d9f0b9c46790009b9874d49253 (MD5) Tese_OtimizacaoMultiobjetivoCompensacao.pdf: 1385522 bytes, checksum: f28192c0b6b8ec65f18eb07c8458c66f (MD5) Previous issue date: 2014 / A localização de bancos de capacitores nas redes de distribuição de energia elétrica, corretamente dimensionados, busca compensar eventuais excessos de circulação de potência reativa pelas linhas, o que implica a redução de custos operacionais pela redução das perdas de energia e um aumento da capacidade de transmissão de potência ativa assegurando os níveis estabelecidos de tensão e fator de potência simultaneamente. A proliferação das cargas não lineares provocou uma mudança nos cenários de estudo dos sistemas elétricos de potência devido aos efeitos nocivos que os harmônicos gerados por elas ocasionam sobre a qualidade da energia elétrica. Considerando este novo cenário, esta tese tem como objetivo geral desenvolver uma ferramenta computacional utilizando técnicas de inteligência computacional apoiada em algoritmos genéticos (AG), para a otimização multiobjetivo da compensação da potência reativa em redes elétricas de distribuição capaz de localizar e dimensionar de forma ótima as unidades de compensação necessárias para obter os melhores benefícios econômicos e a manutenção dos índices de qualidade da energia estabelecidos pelas normas brasileiras. Como Inovação Tecnológica do trabalho a ferramenta computacional desenvolvida permite otimizar a compensação da potência reativa para melhorar do fator de potência em redes de distribuição contaminadas com harmônicos que, diferentemente de métodos anteriores, não só emprega bancos de capacitores, mas também filtros de harmônicos com esse objetivo. Utiliza-se o algoritmo NSGA-II, que determina as soluções ótimas de Pareto para o problema e permite ao especialista determinar as soluções mais efetivas. A proposta para a solução do problema apresenta várias inovações podendo-se destacar que a solução obtida permite determinar a compensação de potência reativa com capacitores em sistemas com certa penetração harmônica, atendendo a normas de qualidade de energia pertinentes, com relação aos níveis de distorção harmônica tolerados. / The localization of capacitors banks in the electric power distribution networks, correctly sized, looks for to compensate eventual excesses of circulation of reactive power for transmission lines, what implies the reduction of operational costs for the reduction of the energy losses and an increase of the capacity of transmission of active power assuring the established levels of voltage and power factor simultaneously. The proliferation of the nonlinear loads produced a change in the scenarios of study of the electric power systems due to the degradation effects that the harmonic generated by them cause about the quality of the electric power. Considering this new scenario, this thesis has as general objective to develop a computational tool using computational intelligence supported in genetic algorithms (GA), for the multiobjective optimization of the reactive power compensation in distribution electric networks able to locate and size in a good way the necessary compensation units to achieve the best economic benefits and the maintenance of the indexes of quality of the energy settled down by the Brazilian norms. As technological innovation of the work, the developed computational tool allows to optimize the compensation of the reactive power to improve the power factor in polluted distribution networks with harmonics that, differently of previous methods, not alone it uses capacitors banks, but also harmonic filters with that objective. The NSGA-II algorithm is used to determine optimal solutions of Pareto for the problem and it allows the specialist to determine the most effective solutions. The formulation proposed in this thesis for the solution of the problem presents several novelties being able to highlight that the achieved solution allows to determine the compensation of reactive power in systems with certain harmonic penetration, complying with pertinent standards of power quality, with respect to the tolerated levels of harmonic distortion.
32

Análise não paramétrica para identificação de fontes de distorções harmônicas em sistemas de energia elétrica: um estudo aplicado no campus universitário do Guamá da Universidade Federal do Pará

MATOS, Edson Ortiz de 19 February 2016 (has links)
Submitted by camilla martins (camillasmmartins@gmail.com) on 2017-03-15T17:26:40Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseNaoParametrica.pdf: 5858237 bytes, checksum: 2ad3f6f508cede019d85d5bec0b35c8f (MD5) / Approved for entry into archive by Edisangela Bastos (edisangela@ufpa.br) on 2017-03-22T14:04:50Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseNaoParametrica.pdf: 5858237 bytes, checksum: 2ad3f6f508cede019d85d5bec0b35c8f (MD5) / Made available in DSpace on 2017-03-22T14:04:50Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Tese_AnaliseNaoParametrica.pdf: 5858237 bytes, checksum: 2ad3f6f508cede019d85d5bec0b35c8f (MD5) Previous issue date: 2016-02-19 / Atualmente, o uso de cargas não lineares e equipamentos baseados em eletrônica de potência nas instalações residenciais, comerciais e industriais estão contribuindo para o aumento significativo dos níveis de distorção harmônica de corrente e, consequentemente de tensão, conforme observado no sistema brasileiro de distribuição de energia elétrica. O aumento contínuo dos níveis de distorção harmônica nas redes elétricas de distribuição tem causado preocupação nas concessionárias e clientes de energia, pois a presença dessas fontes de harmônico no sistema provoca, entre outros, perda da qualidade no fornecimento de energia. Com foco neste problema, a presente tese propõe o desenvolvimento de modelos de regressão não paramétrica para identificar e quantificar quais cargas não lineares podem ser consideradas fontes harmônicas principais, para as distorções de tensão em um ponto de interesse da rede elétrica. A metodologia proposta se baseia na análise de correlação de dados, utilizando modelos estatísticos de regressão não paramétrica para estabelecer a correlação entre as correntes harmônicas das cargas não lineares e a tensão harmônica no ponto de interesse. Este modelo é construído a partir das tensões e correntes harmônicas de mesma ordem respectivamente, obtidas em campanhas de medição através de qualímetros instalados nos pontos de interesse. Além disso, deve-se salientar que essas tensões e correntes harmônicas devem estar em sua unidade base, ao invés de grandezas normalizadas em relação à componente fundamental, de forma a impedir que a mesma influencie na criação do modelo de regressão. Um aspecto importante nesta metodologia está na utilização das técnicas de regressão polinomial local de Kernel, para a estimação das curvas de regressão entre a tensão e a corrente harmônica. Na validação dos modelos introduz-se o coeficiente de determinação R2, o qual pode ser obtido a partir do coeficiente de correlação de Pearson, para mensurar o grau de precisão dos modelos desenvolvidos. A regressão não paramétrica proporciona uma grande flexibilidade na estimação do modelo de regressão, uma vez que a mesma torna possível à realização de um ajuste mais efetivo do modelo às amostras de dados, e, portanto, é capaz de caracterizar a influência de cada fonte harmônica de forma mais detalhada para todo o período de medição. Essa técnica, apresentou resultados muito mais confiáveis e supera as deficiências dos modelos de regressão linear, o qual impõe que as correntes harmônicas das outras fontes, background, não variam quando se analisa uma determinada corrente de carga. Os modelos de regressão linear e não paramétrico foram simulados aplicando-se o programa R, que é uma linguagem e ambiente para cálculos estatísticos e gráficos, e como sistema teste utilizou-se a rede de distribuição elétrica da Universidade Federal do Pará, constituído de 84 (oitenta e quatro) barras de carga em tensão de 13,8 kV. Os resultados obtidos são comparados aos modelos de regressão linear e apresentaram bom desempenhos possibilitando sua aplicação por empresas de distribuição de energia elétrica. / Nowadays, the use of non-linear loads and power electronics-based equipment in residential, commercial and industrial facilities are contributing to the significant increase of current harmonic distortion levels and, consequently voltage harmonic distortions, as noted in the Brazilian distribution systems. Increasing levels of harmonic distortion in electrical distribution networks is a concern to electric utilities and customers, because the presence of these harmonic sources causes, among others, loss of quality in the energy supply. With a focus on this problem, this thesis proposes the development of non-parametric regression models to identify and quantify what non-linear loads can be considered main sources of voltage harmonic distortion at a point of interest in the electric network. The proposed methodology is based on data correlation analysis, using non-parametric regression statistical models to establish the correlation among the non-linear loads harmonic currents and harmonic voltage at a point of interest. This model is built from harmonic voltage and currents measurements, obtained in measuring campaigns using power quality analyzers installed at the points of interest. In addition, it should be pointed out that these harmonic voltages and currents must be express in base units, rather than percent values in relation to the fundamental component, in order to prevent the influence in the creation of the regression model. An important aspect in this methodology is the use of techniques based on Kernel local polynomial regression, for the estimation of the regression model between harmonic voltage and current. To validate the models it is introduced the determination coefficient R2, which can be obtained from the Pearson correlation coefficient, to measure the accuracy degree of the developed models. The non-parametric regression procedure provides a great flexibility in the estimation of regression models, since it makes possible to carry out a more effective model fit to the data samples, and therefore it is able to characterize the influence of each harmonic source in more detail for the entire measurement period. This technique presented more reliable results and overcomes the shortcomings of the linear regression model, which requires the harmonic currents of other sources, called background, not to vary when analyzing a particular load current. The linear and non-parametric regression models were simulated using the program R, which is a language and environment for statistical calculations and graphs, and as test system it was used the Federal University of Pará electric distribution network, consisting of 84 (84) load busbars in 13.8 kV. The results so obtained are compared to those obtained with the linear regression models, and presented good performance, allowing its application for electric power distribution companies.
33

Geração de segundo harmônico em compostos hidrazônicos

Araújo, Raiane Sodré de 27 July 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / In this work, we investigated the phenomenon of second harmonic generation in hydrazone compounds. Based on optical absorption measurements, we determined the energy bands corresponding to the first excited state and the energy gap of the compound. Using the X-ray powder diffraction method, we verified the crystalline nature of the samples. The process of second harmonic generation exhibited by these compounds was characterized by the Kurtz and Perry powder method. We noted that these materials have good efficiency at second harmonic generation, being comparable to KDP. The results indicate that these are promising compounds for the development of photonic applications based on second-order nonlinear optical effects. / No presente trabalho, investigamos o fenômeno de geração de segundo harmônico em compostos hidrazônicos. A partir de medidas de absorção ´optica, determinamos as bandas de energia correspondentes aos primeiros estados excitados e a energia do gap dos compostos. Usando a difra¸c˜ao de raio-X m´etodo do p´o, verificamos a natureza cristalina das amostras estudadas. O processo de gera¸c˜ao de segundo harmˆonico exibidos por esses compostos foi caracterizado pelo m´etodo do p´o de Kurtz e Perry. Observamos que esses materiais apresentam boa eficiˆencia de gera¸c˜ao de segundo harmˆonico compar´aveis ao KDP. Os resultados obtidos indicam que esses compostos s˜ao promissores para o desenvolvimento de aplica¸c˜oes fotˆonicas baseado em efeitos ´opticos n˜ao lineares de segunda ordem.
34

Contribuições ao estudo, projeto e aplicação de filtros ativos híbridos de potência / Contributions to the study, design and application of hybrid active power filters

Silva, Newton da 20 August 2018 (has links)
Orientadores: José Antenor Pomilio, Edson Adriano Vendrusculo / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-20T02:26:04Z (GMT). No. of bitstreams: 1 Silva_Newtonda_D.pdf: 5963220 bytes, checksum: 500403f704e8c3419c8550979ec0b925 (MD5) Previous issue date: 2012 / Resumo: Os filtros híbridos combinam o filtro passivo com o filtro ativo para a obtenção de um filtro que aproveita as qualidades de ambos. O filtro híbrido possui uma redução de potência na sua parte ativa e apresenta um melhor desempenho que o filtro passivo. Existem diferentes topologias de combinações entre o filtro passivo e o filtro ativo, cada uma com suas características. A topologia mais usual é aquela em que o filtro ativo fica em série com o filtro passivo. Neste trabalho será analisada a topologia com o filtro ativo em paralelo com o indutor do filtro passivo. A vantagem desta topologia é a divisão das correntes harmônicas entre ambos os filtros, o que não ocorre na topologia série. O funcionamento do filtro híbrido na compensação das harmônicas de corrente da carga é aprofundado, ampliando as discussões anteriormente publicadas, identificando novas características de operação, contribuindo no estabelecimento de procedimentos de projeto tanto do circuito de potência quanto de controle. Um estudo teórico da atuação do filtro híbrido em um alimentador industrial de média tensão descrito na norma IEEE 519-1992 (workbench) é também apresentado. Resultados experimentais de implementação em um protótipo são apresentados de modo a comprovar a técnica de controle usada e também avaliar a compensação de correntes harmônicas em situações distintas de carga e harmônico de tensão na rede / Abstract: Hybrid Filters combine the passive filter with the active filter to obtain a filter that takes advantage of the qualities of both. The hybrid filter has a power reduction in its active part and presents better performance than the passive filter. There are different topologies of the combinations between the passive filter and the active filter, each with its own characteristics. The most common topology is the active filter in series with the passive filter. In this work the topology that will be analyzed is one where the active filter is parallel to the inductor of the passive filter. The advantage of this topology is the division of the harmonic current between the two filters, this does not occur in the series topology. The operation of the hybrid filter in the compensation of the load harmonic current is improved, expanding the discussions previously published, identifying new characteristics of operation, contributing to the establishment of design procedures in the power circuit as in the control. A theoretical study of the hybrid filter performance in an industrial medium voltage power supply described in IEEE standard 519-1992 (workbench) is presented too. Experimental results from a prototype implementation are presented in order to check the control technique used and also to evaluate the current harmonic compensation in different situations of the load and harmonic voltage in the source / Doutorado / Energia Eletrica / Doutor em Engenharia Elétrica
35

Estudo e aplicação de filtros ativos paralelos para sistemas trifasicos com quatro fios / Development and application of shunt active filters for three-phase four-wire systems

Villalva, Marcelo Gradella, 1978- 03 October 2005 (has links)
Orientador: Ernesto Ruppert Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-04T17:39:56Z (GMT). No. of bitstreams: 1 Villalva_MarceloGradella_M.pdf: 5074196 bytes, checksum: 39f4e09d9f1f624c909a5ee7f2d3fa4d (MD5) Previous issue date: 2005 / Resumo: o tema da qualidade de energia elétrica adquiriu grande importância em anos recentes. O número crescente de cargas baseadas em conversores eletrônicos criou a preocupação com a distorção harmônica em sistemas de energia elétrica. Qualidade de energia é um assunto importante tanto para as companhias distribuidoras e geradoras de energia elétrica como para os consumidores. A poluição harmônica pode causar sérios problemas às companhias e aos consumidores. Alguns dos possíveis problemas são a instabilidade na operação do sistema, distorções de tensão, perdas de energia, interferência eletromagnética e ressonâncias perigosas. A utilização de equipamentos para eliminação de harmônicos tornou-se necessária e são versas as soluções possíveis. Tradicionalmente se utilizam Itros passivos do tipo série ou paralelo. Esses Itros resentam como desvantagem suas grandes dimensões, seu custo elevado, elevadas perdas de energia, pouca e cácia, dependendência da interação com parâmetros do sistema e risco de introdução de novas freqüências de ressonância. O desenvolvimento recente da eletrônica de potência e do processamento digital de sinais tornou possível a utilização de Itros ativos de potência, que são condicionadores eletrônicos de energia. Filtros ativos de potência podem ser utilizados para realizar a Itragem de harmônicos em sistemas elétricos, sem os problemas apresentados pelos dispositivos passivos. Filtros ativos série são utilizados para eliminar distorções de tensão e Itros ativos paralelos são usados para eliminar correntes harmônicas originadas por carga não lineares. Esses últimos podem ainda ser usados para corrigir o fator de potência e para equilibrar as correntes de linha em sistemas desbalanceados com quatro os. Este trabalho estuda a aplicação de Itros ativos paralelos a sistemas trifásicos com quatro os. São estudados teorias de potências, métodos de compensação de harmônicos e sistemas de controle. A principal contribuição do trabalho está no emprego de um método seletivo de compensação de correntes baseado em redes neurais adaptativas, além do estudo do emprego de redes neurais no controle de correntes. Esses e outros assuntos foram experimentalmente comprovados com um protótipo de Itro ativo construí do em laboratório / Abstract: Electricity power quality has gained increased importance in the past few years. The growing number of power electronicsbased loads has created a preoccupation about harrnonic distortion in electric systems. Electricity power quality is an important issue both for energy utilities and consumers. Harrnonic poIlution may cause severe problems to electricity utilities and consumer networks such as system instability, voltage distortions, power losses, electromagnetic interference and harrnful resonances. The use ofharrnonic ltering equipment has become necessary and many solutions have been studied. Traditional passive devices such as tuned shunt lters and series reactors present disadvantages such as bulky sizes, high costs, increased losses, smaIl effectiveness, dependence on the parameters of the electric system and yet more risk of resonance with other elements of the network. Recent deve10pments in the major of power electronics and digital processing have made possible the pplication of electronic power conditioners such as series and shunt active lters. Active power lters may be used to overcome the drawbacks of passive devices. Series active power lters are used to reduce voltage distortions of electric systems. Shunt active power lters are used to mitigate harrnonic currents originated by nonlinear loads. The latter may be also used for increasing power factor and for balancing line currents in four-wire systems with unbalanced loads. This work is concerned with the application of shunt active power lters to three-phase four-wire electric systems. Power theories, compensation methods and control systems are discussed. The application of a se1ective compensation method based on adaptive neural networks and the employment of a neural network in the current controlIer are the main contributions of this work. These and other subjects were experimentalIy tested with a prototype of an active. power lter built in laboratory / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica
36

Fluxo de carga trifásico para análise de distorções harmônicas em redes de distribuição de energia elétrica / Three-phase power flow for harmonic distortion analysis in power distribution networks

Duque, Marina Borges 22 August 2018 (has links)
Orientador: Carlos Alberto Favarin Murari / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-22T04:03:37Z (GMT). No. of bitstreams: 1 Duque_MarinaBorges_M.pdf: 1960535 bytes, checksum: 1d0e3bb5b148b1377f1e8e33d3ab25ac (MD5) Previous issue date: 2013 / Resumo: Para garantir o bom desempenho das redes de distribuição de energia elétrica, bem como aumentar a qualidade dos serviços prestados aos consumidores, faz-se necessário o desenvolvimento e a implementação de metodologias que permitam avaliar tanto os custos como os benefícios que trazem as diferentes alternativas de projeto propostas e os seus impactos no sistema como um todo, mantendo sempre aceitáveis os índices de qualidade e confiabilidade do fornecimento aos diferentes consumidores: residencial, comercial e industrial. Nesse contexto, um programa computacional que realize o cálculo dos fluxos de potência é uma ferramenta imprescindível na análise dos sistemas elétricos de potência tendo-se como principais grandezas de interesse, as tensões nas diferentes barras e os fluxos de potência ativa e reativa em todos os componentes da rede elétrica (linhas, transformadores, etc.). E como a maior parte das redes de distribuição de energia elétrica é trifásica, é de fundamental importância adotar uma formulação trifásica que represente de forma adequada os desequilíbrios, e, portanto nesta dissertação é apresentada uma versão de fluxo de carga trifásico baseada no Método Iterativo de Correção de Tensão com possibilidade de inserção de cargas não lineares para contemplar as frequências harmônicas e assim obter o estado da rede (magnitude e ângulo das tensões nodais) e também de outras grandezas elétricas contemplando os efeitos causados por cargas não lineares, com ênfase para o motor de indução trifásico / Abstract: To ensure a good performance of power distribution networks as well as to increase the quality of services provided for the consumers, it is necessary the development and implementation of methodologies to assess the costs and the benefits of the different operating alternatives and their impacts on the system as a whole, while maintaining acceptable levels of quality and the reliability of electricity supply to the various consumers: residential, commercial and industrial. In this context, a computer program that performs the calculation of power flows is an essential tool in the analysis of electrical power systems having as main quantities of interest - nodal voltages and active and reactive power flows - at all electrical network components (lines, transformers, etc.). Once the electrical distribution networks are three-phase, it is crucial to adopt a three-phase formulation that adequately represents the load unbalance. We propose a version of a three-phase load flow based on the Voltage Correction Iterative Method with the possibility of including non-linear loads - with emphasis for three-phase induction motor - to simulating harmonic frequencies and getting the corresponding node voltages and other electrical quantities / Mestrado / Energia Eletrica / Mestra em Engenharia Elétrica
37

Análise do impacto de conversores de frequência na qualidade da energia do sistema de distribuição de uma indústria de petróleo

MAGALHÃES, Christiane Marques Sousa de 06 October 2010 (has links)
Submitted by Edisangela Bastos (edisangela@ufpa.br) on 2012-04-13T18:54:52Z No. of bitstreams: 2 Dissertacao_AnaliseImpactoConversores.pdf: 3431144 bytes, checksum: 1d9f792ba412f7aa01d7a772d9274800 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Approved for entry into archive by Edisangela Bastos(edisangela@ufpa.br) on 2012-04-13T18:56:10Z (GMT) No. of bitstreams: 2 Dissertacao_AnaliseImpactoConversores.pdf: 3431144 bytes, checksum: 1d9f792ba412f7aa01d7a772d9274800 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) / Made available in DSpace on 2012-04-13T18:56:10Z (GMT). No. of bitstreams: 2 Dissertacao_AnaliseImpactoConversores.pdf: 3431144 bytes, checksum: 1d9f792ba412f7aa01d7a772d9274800 (MD5) license_rdf: 23898 bytes, checksum: e363e809996cf46ada20da1accfcd9c7 (MD5) Previous issue date: 2010 / Apresenta-se neste trabalho uma análise da qualidade da energia do sistema de distribuição de uma indústria de petróleo, de modo a avaliar o impacto da instalação de conversores de frequência no que diz respeito ao fenômeno de distorção harmônica. Os dados de distorção harmônica de tensão foram coletados através de duas medições com duração de sete dias consecutivos, sendo uma realizada antes e outra depois da instalação dos conversores de frequência. Adicionalmente, um estudo computacional utilizando o PTW (Power Tools for Windows) é apresentado com o intuito de simular condições futuras de instalação de novos conversores de frequência e de avaliar a influência dos bancos de capacitores na amplificação da distorção harmônica no sistema de distribuição. / In this work, it is presented an analysis of the distribution system power quality of an oil industry in order to evaluate the impact of the installation of frequency converters regarding the harmonic distortion. The harmonic distortion data were collected through two measurements over a period of seven consecutive days, one performed before and other after the installation of frequency converters. Additionally, a computational study using PTW (Power Tools for Windows) is presented in order to simulate future conditions of new frequency converters installation and to analyse the influence of capacitor banks in the amplification of distribution system harmonic distortion.
38

Estudo do controle com Feedforward de potência e realimentação direta aplicado ao retificador Boost Bridgeless com alto fator de potência

Ganacim, Júlio César Secolo 04 December 2014 (has links)
Neste trabalho é apresentado um estudo de controladores aplicados a retificadores boost pré reguladores de alto fator de potência. A estratégia convencional, mais utilizada, é o controle por valores médios instantâneos que apresenta uma malha de corrente rápida e uma malha de tensão lenta. A frequência de corte desta última malha é baixa devido a ondulação de tensão de saída no dobro da frequência da rede que deve existir para apresentar uma corrente de entrada com baixa distorção harmônica. Esses controles apresentam um sobressinal elevado e transição lenta durante transitórios de carga, levando a elevação da tensão dos capacitores de saída. A técnica apresentada é um controlador digital com feedforward de potência de saída associado a uma malha de realimentação direta, também conhecido como autocontrole. Essa estratégia possibilita melhores resultados nos transitórios de carga possibilitando redução do capacitor de saída com reduzido sobressinal no transitório de carga. / In this work a study applied in controlled boost rectifiers with high power factor is presented. A most widely used conventional control strategy is the instant average current control, this kind of control have a fast current loop and a slow voltage loop.The cutoff frequency of the voltage loop is low because the output voltage ripple must be twice the frequency of the input network, that need to exist to provide an input current with low harmonic distortion. These controllers feature a high overshoot and a slow transition during the transient load what leads a high voltage in the output capacitors. The developed technique is a digital controller that operate with a feedforward output power associated with one cycle control. This strategy provides better results in the load transient, reducing the overshoot and alloying a reduction of the output capacitor.
39

Estudo do controle com Feedforward de potência e realimentação direta aplicado ao retificador Boost Bridgeless com alto fator de potência

Ganacim, Júlio César Secolo 04 December 2014 (has links)
Neste trabalho é apresentado um estudo de controladores aplicados a retificadores boost pré reguladores de alto fator de potência. A estratégia convencional, mais utilizada, é o controle por valores médios instantâneos que apresenta uma malha de corrente rápida e uma malha de tensão lenta. A frequência de corte desta última malha é baixa devido a ondulação de tensão de saída no dobro da frequência da rede que deve existir para apresentar uma corrente de entrada com baixa distorção harmônica. Esses controles apresentam um sobressinal elevado e transição lenta durante transitórios de carga, levando a elevação da tensão dos capacitores de saída. A técnica apresentada é um controlador digital com feedforward de potência de saída associado a uma malha de realimentação direta, também conhecido como autocontrole. Essa estratégia possibilita melhores resultados nos transitórios de carga possibilitando redução do capacitor de saída com reduzido sobressinal no transitório de carga. / In this work a study applied in controlled boost rectifiers with high power factor is presented. A most widely used conventional control strategy is the instant average current control, this kind of control have a fast current loop and a slow voltage loop.The cutoff frequency of the voltage loop is low because the output voltage ripple must be twice the frequency of the input network, that need to exist to provide an input current with low harmonic distortion. These controllers feature a high overshoot and a slow transition during the transient load what leads a high voltage in the output capacitors. The developed technique is a digital controller that operate with a feedforward output power associated with one cycle control. This strategy provides better results in the load transient, reducing the overshoot and alloying a reduction of the output capacitor.

Page generated in 0.0668 seconds