• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 3
  • 1
  • Tagged with
  • 7
  • 7
  • 5
  • 5
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Extending the pump energy range for a pump-probe system using High Harmonics Generation

FLE, Guillaume January 2015 (has links)
No description available.
2

Caractérisation de l’endommagement thermique et mécanique dans le mortier par les ondes acoustiques non linéaires / Characterization of heat and mechanical damage in the mortar by nonlinear acoustic waves

Yousfi, Ismail 29 May 2015 (has links)
L'objectif de ce travail est la caractérisation de l’endommagement thermique et mécanique dans le mortier par les ondes acoustiques non linéaires. La corrélation entre les paramètres acoustiques linéaires et non-linéaires étudiée est basée sur les essais expérimentaux et la modélisation. Pour l’endommagement thermique, des éprouvettes cylindriques ont été préparées et caractérisées par l'étude de la porosité et la saturation. Ensuite, l'acoustique linéaire et l’acoustique non linéaire (génération d'harmoniques) ont été appliquées afin de quantifier l’endommagement. Les essais acoustiques linéaires ont prouvé que les vitesses transversales, longitudinales et le module d'Young du mortier diminue en fonction de la température. Les essais acoustiques non linéaires ont montré l'augmentation du bêta fonction de la température. Pour l’endommagement mécanique, le phénomène d'autocicatrisation est suivi par la perméabilité et les essais acoustiques. Les essais de perméabilité ont montré que le débit d'air et la taille de la fissure diminue rapidement au cours du premier mois, puis lentement durant le reste du processus d'autocicatrisation. D'autre part, les tests acoustiques non linéaires ont montré que « alpha » et « bêta » diminuent durant le processus de l’autocicatrisation qui signifie que les paramètres non linéaires sont un bon indicateur pour caractériser ce phénomène. A partir des résultats expérimentaux, une corrélation polynomiale de 2ème degré a été établie entre les paramètres non linéaires et l’index d’endommagement. Les résultats de ce travail représentent un bon départ pour étudier le phénomène de l'autocicatrisation par les ondes acoustiques non linéaires / The objective of this work is the characterization of heat and mechanical damage in the mortar by the nonlinear acoustic waves. The correlation between non-linear/linear acoustic parameters and damage in mortar is studied based on experiments and modelling. For the heat damage, cylindrical specimens were prepared and were characterized by studying the porosity and saturation. Indeed, the linear acoustic (UPV) and non-linear acoustic (Higher harmonic generation) were applied to characterize the damage. The linear acoustic tests have shown that velocities and modulus of Young of the mortar decreases in function of the temperature. The non-linear acoustic tests have shown that beta increases in function of the temperature.For the mechanical damage. The self-healing phenomenon was characterized by the permeability and the acoustic tests. Indeed, the permeability tests have shown that the airflow and the crack size decreases quickly in the first month then slowly for the rest of the self-healing process. On the other hand, the non-linear acoustic tests shown that the alpha and beta decreases according to the self healing process which means that the nonlinear parameters are a good indicators to characterize the self-healing. Moreover, the analysis of the experimental results indicates that the frequency resonant technique is more efficient to characterize the defects in the mortar than the higher harmonic generation. A polynomial correlations of a 2nd degree was established between the nonlinear parameters and the index damage. The findings of this work should be most appropriate as a foundation for the study of the self healing by the nonlinear acoustic waves
3

Generation of intense high harmonics: i) to test and improve resolution of accumulative x-ray streak camera ii) to study the effects of carrier envelope phase on XUV super continuum generation by polarization gating

Shakya, Mahendra Man January 1900 (has links)
Doctor of Philosophy / Department of Physics / Zenghu Chang / The first part of this thesis describes our novel design, test, and application of our X-ray streak camera to the pulse duration measurement of soft X-rays. We demonstrated a significant improvement in the resolution of the x-ray streak camera by reducing the electron beam size in the deflection plates. This was accomplished by adding a slit in front of the focusing lens and the deflection plates. The temporal resolution reached 280 fs when the slit width was 5 μm. The camera was operated in an accumulative mode and tested by using a 25 fs laser with 2 kHz repetition rate and 1-2% RMS pulse energy stability. We conclude that deflection aberrations, which limit the resolution of the camera, can be appreciably reduced by eliminating the wide-angle electrons. We also employed the same streak camera to demonstrate that it is capable of measuring the pulse duration of X-rays. We measured the pulse duration of X-rays emitted from Ni-like Ag and Cd grazing-incidence laser to be ~5ps. The measured value agrees with the prediction made by the model and the measurement made by changing the delay as a function of the pulse duration. The streak camera was also tested with various sources of X-ray such as high harmonics generation of soft x-rays from an argon atom using a high power Ti:sapphire laser source of KLS. The result of the measurement manifests its capability for serving as a detector in the study of ultrafast dynamics in the field of physics, chemistry, biology and medical sciences. The second part of this thesis describes our design of a spectrometer to study the effect of the Carrier envelope (CE) phase on polarization gated extreme-ultraviolet (XUV) super-continuum generation. Because the challenge of making single shot experiment possible is to generate a sufficient number of photons, our setup has been built to allow generation of high order harmonics at the maximum phase matched pressure. This is the first time to our knowledge that phase matching in the polarization gating process has been studied so far. We measured the maximum phase matching pressure to be ~ 55 Torr which is the pressure above which quadratic increase in intensity of the high harmonics spectrum ceases to appear. At this pressure the number of photons per laser shot was 104 which is sufficient for measuring the single shot XUV spectrum in the range 34 to 45 eV. The spectral profile was a super-continuum for some shots and discrete high harmonics for other shots. It is believed that the shot to shot variation of the spectra is due to the changes of the carrier envelope phase of the few-cycle laser pulses used for the polarization gating. An improved CE phase stabilization system in KLS further eliminated the statistical noise in our observation by allowing us to integrate data over several laser cycles for each CE phase value. The effect of CE phase on a polarization gated XUV spectrum was tested by changing the CE phase with two different methods. In the first method, the CE phase was changed by changing the thickness of fused silica plates on the beam path, and the result shows the shift in the spectral peak of the XUV when the gate width approached less than one optical cycle. As gate width was made less than half the optical cycle, the spectrum was observed with continuum harmonics separated by π radians. We believe that the presence of continuum and discrete harmonics spectra in the observation is due to single and double attosecond pulses generated in the polarization gating. In the second method the carrier-envelope phase of pulses from a grating-based chirped pulse amplification laser was varied smoothly to cover a 2π range by controlling the grating separation. The phase is measured simultaneously by an f-to-2f setup and by the variation of XUV spectra from polarization gated high harmonic generation. A very good similarity between the effect of single and double slits in Yong’s experiment and that of CE phase on the XUV spectrum in the polarization gating experiment has been found, giving better agreement with the theory. The effect of optical properties such as the Gouy phase shift on the polarization gated spectrum has also been studied in the course of investigating the best experimental optimizations to generate the most CE phase sensitive XUV spectrum with less statistical noise. This is the first time to our knowledge experimental study of the effect of the Gouy phase shift on a polarization gated XUV spectrum has been made.
4

Développement de sources lasers femtosecondes ytterbium à très haute cadence et applications / High repetition rate femtosecond ytterbium lasers and applications

Machinet, Guillaume 03 July 2013 (has links)
Ce travail de thèse est consacré au développement de sources lasers femtosecondes à haute cadence, de forte puissancemoyenne (>10 W) avec des énergies supérieures à 100 μJ. Ce type de sources est primordial pour le développementd’applications industrielles variées (micro-usinage athermique, chirurgie oculaire, …) ainsi qu’en recherchefondamentale pour l’étude de l’interaction laser matière.Après un chapitre d’introduction sur l’état de l’art des chaînes lasers de forte puissance moyenne à base de matériauxdopés ytterbium, la réalisation d’une chaîne laser de forte puissance moyenne compacte à base de fibre photoniquemicrostructurée à large aire modale sera présentée. Il sera notamment démontré les principales limitations en termed’énergie et de puissance moyenne. D’une part, le fort confinement de l’impulsion lumineuse dans le coeur de la fibrefavorise l’accumulation d’effets non-linéaires lors de l’amplification et détériore la qualité de l’impulsion. D’autrepart, en raison du diamètre de coeur important (> 70 μm) choisit pour lutter contre l’effet précèdent, le guidage dumode fondamental TEM00 de ces fibres est très critique et devient sensible à la charge thermique interne à la fibre.Cette source laser a été utilisée dans le cas de deux applications bien spécifiques : le perçage de plaques d’acierépaisses pour une finalité de déminage (relatif au cadre du financement de cette thèse par la Direction Générale del’Armement) et à la génération d’harmoniques d’ordres élevées à très haute cadence (relatif au domaine d’expertisedu CELIA). Ces deux applications sont traitées au cours du troisième chapitre.A la vue des limitations observées et afin de disposer de chaînes lasers plus énergétiques et offrant des duréesd’impulsions encore plus courtes, une nouvelles architecture d’amplification a été proposée : le pompage fortebrillance de matériaux dopés Ytterbium. Ce concept présenté dans le dernier chapitre utilise le développement desources fibrées monomodes continues émettant à 976 nm. Cette architecture d’amplification a été utilisée afin deréaliser d’une part un oscillateur sub-70 fs et de forte puissance moyenne (>2,3 W) à une cadence de 73 MHz etd’autre part : un amplificateur type « booster » à fort gain. Deux expériences qui ont été réalisées avec des cristauxd’Yb:CaF2. Ce matériaux présente en effet l’avantage d’avoir un très large spectre d’émission (>60 nm) propice à lagénération et amplification d’impulsions femtosecondes mais aussi d’être « compatible » avec les chaînes de trèsforte puissance grâce à sa très bonne conductivité thermique. / This work concerns the development of high repetition rate femtosecond lasers with high average power (>10 W)and energies in excess of 100 μJ. Such lasers are paramount for the development of new industrial applications(athermal micro-drilling, eye surgery, ...) and for fundamental research on high repetition rate laser matter interactionstudies.After a brief introduction and the state of the art summary on high-average power femtosecond laser with ytterbiumdoped materials, a compact high-average power femtosecond laser with a large mode area microstructured rod typeamplifier will be presented. It will browse the main limitations in terms of energy and average power. Limitationsare mainly due to the strong confinement of the electric field propagating in the fibre core leading to non-linear effectsaccumulated during the amplification. On the other hand, for larger core diameter (> 70 μm), the fundamental modeguiding (TEM00) is very weak and thus very sensitive to the internal thermal load of the fibre.This laser source has been used in two specific applications: athermal drilling of thick stainless steel plate for mineclearing(an application of interest for the Direction Générale de l’Armement) and High order Harmonics Generationat high repetition rate (related to CELIA activities). These two applications are presented in the third chapter.In order to stretch the limits and generate more energetic and a shorter pulse, a new amplification scheme has beenproposed, namely high brightness optical pumping of ytterbium doped materials. This concept presented in the lastchapter benefits from the development of high average power single-mode fibre lasers source emitting at 976 nm.This amplification scheme allowed us to realize a high average power Kerr-lens oscillator delivering pulses with apulse duration below than 70 fs and an average power of 2.3W at a repetition rate of 73 MHz. In a second phase, wealso developed a « booster » amplifier with a high single- pass-gain. These two results have been obtained by usingYb-doped CaF2 crystals. This material presents the advantage to have a very broad emission bandwidth (> 60nm)suitable to generate and amplify femtosecond pulses and to be compatible with high average power laser due to hisvery good thermal conductivity.
5

Imagerie nanométrique ultra-rapide par diffraction cohérente de rayonnement extrême-UV produit par génération d'harmoniques d'ordre élevé / Ultrafast nanometers scale coherent diffractive imaging with extreme-UV light from high harmonics generation beamline

Gauthier, David 07 February 2012 (has links)
Ce manuscrit présente des expériences d’imagerie par diffraction réalisées en utilisant une source de rayonnement cohérent basée sur la génération d’harmoniques d’ordre élevé d’un laser Ti:Sa. Elles démontrent que cette source extrême-UV de laboratoire produit un nombre suffisant de photons par impulsion pour enregistrer une figure de diffraction d’objets tests en « simple tirs ». Le signal ainsi enregistré permet l’obtention d’une image de l’objet avec une résolution d’une centaine de nanomètres. Deux schémas sont utilisés pour reconstruire l’objet : le premier utilise un algorithme itératif de reconstruction de la phase perdue pendant la détection de la figure de diffraction ; le second utilise une configuration holographique par transformée de Fourier. Les travaux réalisés comportent deux parties. La première concerne l’optimisation de la source harmonique et inclut une étude expérimentale d’un dispositif de filtrage spatial du faisceau laser de génération par propagation dans une fibre creuse. La seconde partie présente les expériences d’imagerie par diffraction, et notamment une démonstration du schéma holographique HERALDO qui est une extension de l’holographie par transformée de Fourier à des références en forme de polygones. L’utilisation de ces références « étendues » a pour avantage d’optimiser l’enregistrement holographique tout en conservant une reconstruction directe et sans ambigüité de l’objet. Une analyse signal-sur-bruit ainsi qu’une comparaison des reconstructions d’hologramme pour différentes formes de références sont effectuées. / This manuscript presents diffraction imaging experiments performed using a source of coherent radiation based on high order harmonics generation of a Ti:Sa laser. They demonstrate that this laboratory size XUV source produces a number of photons per pulse sufficient to record the diffraction pattern of test objects in « single shot ». The signal thus recorded allows obtaining an image of the object with a resolution of around 100 nanometers. Two schemes are used to reconstruct the object: the first one uses an iterative algorithm to retrieve the phase lost during the detection of the diffraction pattern; the second uses a configuration of Fourier transform holography. The work presented here is separated in two parts. The first one concerns the optimization of the harmonic source, including an experimental study of a spatial filtering device for laser beams by propagation in a hollow core fiber. The second part deals with the diffraction imaging experiments. In particular, I present a demonstration of the holographic scheme HERALDO, which is an extension of the Fourier transform holography with polygonal references. The use of these « extended » references allows the optimization of the holographic recording while maintaining a direct and non-ambiguous reconstruction of the object. An analysis of signal-to-noise ratio and a comparison of hologram reconstructions for different types of references are performed.
6

Post compression d'impulsions intenses ultra-brèves et mise en forme spatiale pour la génération d'impulsions attosecondes intenses / Post compression of high energy ultra-short pulses and spatial shaping of intense laser beams for generation of intense attosecond pulses

Dubrouil, Antoine 28 October 2011 (has links)
La génération d'harmoniques d'ordre élevé en milieu gazeux est un phénomène habituellement décrit par un modèle à trois étapes : sous l'effet d'un champ laser intense, un atome (ou une molécule) est ionisé par effet tunnel. L'électron éjecté est accéléré dans le champ laser, puis il se recombine sur son ion parent en émettant un photon XUV. Ce rayonnement XUV, émis sous la forme d'impulsions attosecondes (1 as = 10-18 s), est un outil idéal pour sonder la structure électronique des atomes ou des molécules, avec une résolution temporelle de l'ordre de l'attoseconde. Néanmoins, l'intensité de ce rayonnement n'est en général pas suffisante pour induire des effets non-linéaires (transitions à deux photons).Au cours des travaux réalisés pendant cette thèse, nous avons développé une source harmonique capable de produire un rayonnement XUV intense qui doit permettre d'accéder à la physique non-linéaire dans cette gamme de longueur d'onde. Pour parvenir à ces résultats, un travail important sur les impulsions infrarouges génératrices a été nécessaire, aussi bien dans le domaine spatial que dans le domaine temporel. Une technique de mise en forme spatiale de faisceaux laser intenses a donc été développée, ainsi qu'une technique de post compression adaptée aux impulsions laser intenses. Ce travail de thèse se divise donc en trois étapes : - Le développement de la source harmonique haute énergie et des diagnostics associés. Cette source est basée sur l'utilisation d'une chaîne laser Titane-Saphir qui délivre des impulsions de 150 mJ pour des durées de 40 fs à une cadence de 10 Hz. De bonnes conditions d'optimisation ont été obtenues, donnant lieu à des impulsions XUV dont l'énergie est de l'ordre du µJ lors de la génération dans l'argon.- Le développement d'une technique de mise en forme spatiale adaptée aux faisceaux laser intenses et à la génération d'harmoniques. Le dispositif est basé sur une optique en réflexion et sur les interférences à deux faisceaux. Il permet de produire, dans la région focale, des faisceaux dont le profil d'intensité est radialement constant (faisceaux flat top) et ainsi d'apporter un contrôle supplémentaire sur la génération d'harmoniques d'ordre élevé.- Le développement d'une technique de post compression en propagation guidée basée sur l'élargissement spectral induit par ionisation. Cette technique est adaptée pour des impulsions intenses (3.5 TW) et permet de produire des impulsions de puissance crête supérieure au Térawatt dans le domaine sub-10 fs. Cette technique fournit donc une source unique pour la génération d'harmoniques d'ordre élevé.Ces deux approches ont été testées et validées pour la génération d'harmoniques d'ordre élevé, et les résultats obtenus ouvrent d'intéressantes perspectives telles que la génération d'impulsions attosecondes isolées de haute énergie (> 100 nJ). / The generation of high order harmonics in a gaseous medium is a phenomenon conveniently described by a three steps model : subject to a strong laser field irradiation, an atom (or molecule) can undergo a tunneling ionization. The ejected electron is accelerated in the laser field and recombine on its parent ion leading to the emission of an XUV photon. The XUV radiation can be emitted as attosecond pulses (1 as = 10-18 s), and it is then an ideal tool to probe the electronic structure of atoms or molecules which require the highest time resolution. However, the intensity of this radiation is usually not sufficient to induce non-linear processes (two-photon transitions).In the frame of this work, we have developed a harmonic source capable of producing an intense XUV radiation to access non-linear physics in this wavelength domain.To achieve these results, significant work on the infrared generating pulses was necessary, both in the spatial and temporal domain. We have developed a technique for spatial shaping of intense laser beams, and a post compression technique fitted to high energy pulses.This thesis is therefore divided into three parts:- The development of an high energy harmonic source and related diagnostics. We use a Ti: sapphire laser system for this source which delivers 40-fs pulses up to an energy of 150 mJ at 10 Hz repetition rate. Good optimization conditions were obtained, leading to XUV pulse energies of the order of μJ in the case of generation in argon.- The development of a spatial shaping technique adapted to intense laser beams and to harmonic generation. The device is based on reflection optics and the interferences of two beams. It can produce, in the focal region, beams with a radially constant intensity over a large volume (flat top beams) and thus provide additional control of the harmonics generating process.- The development of a post compression technique in guided geometry based on the ionization induced spectral broadening. This technique is suitable for intense pulses (3.5 TW) and produces pulses above the terawatt level in the 10-fs range. This technique therefore provides a unique source for harmonic generation.These two approaches have been tested and validated for high order harmonics generation, and the results open interesting perspectives such as the generation of isolated attosecond pulses of high energy (> 100 nJ).
7

Imagerie ultrarapide à l’échelle nanométrique par diffraction XUV cohérente / Ultrafast coherent XUV diffractive imaging at nanometer scale

Ge, Xunyou 11 December 2012 (has links)
Imager des objets non-périodiques à une échelle nanométrique et à une échelle femto seconde est un vrai challenge à notre époque. Les techniques d’imagerie « sans lentille » sont des moyens puissants pour répondre à ce besoin. En utilisant des sources ultrarapide (~fs) et cohérente (ex. laser à électron libre ou harmoniques d’ordres élevés), ces techniques nous permettent de reconstruire des objets à partir de leur figure de diffraction, remplaçant les optiques conventionnelles du système d’imagerie par un algorithme informatique. Dans ce travail de thèse, je présent des expériences d’imageries en utilisant un rayonnement extrême-UV (15~40 nm) produit par la génération d’harmoniques d’ordre élevé d’un laser infrarouge puissant. Ce manuscrit est constitué d’une introduction, un chapitre de background théorique, trois chapitres de travail de thèse et une conclusion générale avec perspectives. La première partie du travail de thèse porte sur les développements et caractérisations de la ligne de lumière avec l’objectif de générer maximum de photons harmoniques cohérents avec un front d’onde plat. La deuxième partie est consacrée aux expériences et analyses de trois techniques d’imageries « sans lentille » : Imagerie par diffraction cohérente (CDI), Holographie par la transformée de Fourier (FTH) et Holographie avec références étendues (HERALDO). Ces derniers nous permettent de reconstruire des objets avec une résolution spatiale de 78 nm dans le cas de CDI et de 112 nm dans le cas de HERALDO, tous les deux avec une résolution temporaire de 20 fs. La troisième partie est une première application physique de l’imagerie sur la ligne harmonique. Il s’agit des études statiques et dynamiques de nano-domaines magnétique avec une résolution spatiale sub-100 nm à l’échelle femto seconde. Perspective des techniques d’imagerie 3D et développement potentiel de la ligne d’harmoniques sont présentés à la fin. / Ultrafast imaging of isolated objects with nanometric spatial resolution is a great challenge in our time. The lensless imaging techniques have shown great potential to answer this challenge. In lensless imaging, one can reconstruct sample images from their diffraction patterns with computational algorithms, which replace the conventional lens systems. Using ultrafast and coherent light sources, such as free electron laser and high order harmonics, one can investigate dynamic phenomena at the femtosecond time scale. In this thesis work, I present the lenless imaging experiments using XUV radiation provided by a laser driven high order harmonic beamline. The manuscript is composed of an introduction, a chapter of theoretical background, three chapters of main research work and a general conclusion with perspectives. The first part of this work concerns the development of the harmonic beamline to optimize the illumination condition for lensless imaging. The second part concentrates on the imaging techniques: the Coherent Diffraction Imaging (CDI), the Fourier Transform Holography (FTH) and the Holography using extended references (HERALDO). The reconstructions have achieved 78 nm spatial resolution in case of CDI and 112 nm resolution in case of HERALDO, both in single-shot regime corresponding to a temporal resolution of 20 fs. The third part presents the first physical application on the harmonic beamline using the lensless imaging. Samples with magnetic nano-domains have been studied with sub-100 nm spatial resolution, which paves the way for ultrafast magnetic dynamic studies. At the end, single-shot 3D imaging and further beamline development have been discussed.

Page generated in 0.2989 seconds