• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 4
  • Tagged with
  • 11
  • 11
  • 7
  • 6
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

An insight intro nanostructures through coherent diffraction imaging / Une contribution à l'étude des nanostructures par diffraction cohérente des rayons X

Fernandez, Sara 01 December 2016 (has links)
La manipulation des propriétés physiques des nanostructures, telles que leur forme ou leur composition, suscite de plus en plus l’intérêt des recherches à cause des propriétés exceptionnelles des matériaux à cette échelle. L’ingénierie des contraintes a pour objet d’utiliser la déformation pour contrôler les propriétés. Cela est particulièrement intéressant dans les nano-objets car ils peuvent supporter des déformations élastiques élevées. Dans ce travail, nous étudions la déformation et l’influence de la température dans des nanofils uniques de type coeur/coquille. Ceci est possible en utilisant la diffraction cohérente des rayons X (CDI) en condition de Bragg, une technique d’imagerie qui remplace les lentilles optiques par des algorithmes d’inversion capables de reconstruire l’amplitude (densité électronique) et la phase (projection du champ de déplacement atomique) de l’échantillon à partir des clichés de diffraction. Cette méthode a également été appliquée à des particules facettées de platine qui ont des propriétés catalytiques exceptionnelles. Des expériences CDI in situ ont permis d’étudier l’évolution du champ de déformation dans les particules pendant des réactions chimiques et donc de progresser vers le découplage entre leur déformation intrinsèque et leur activité chimique. / Manipulating the physical and chemical properties of nanostructures by changing their characteristics (such as shape, strain or composition) is a vivid field of research spurred by the numerous applications that may take advantage of the unique properties that materials offer at this scale.Strain engineering aims to tune the strain in order to control the properties of materials. This is particularly interesting in nano-objects because they can sustain much higher elastic strains before the occurrence of defects. In this work, we study the strain and the influence of temperature in single core/shell nanowires. This is possible thanks to X-ray coherent diffraction (CDI) in Bragg condition, an imaging technique that replaces the optical lenses by inversion algorithms that are able to reconstruct the amplitude (electronic density) and the phase (projection of the atomic displacement field) of the sample from the experimental diffraction patterns. In addition to nanowires, the method is applied to metallic particles of platinum with exceptional catalyticproperties. In situ CDI experiments allowed to study the strain evolution within particles during chemical reactions, thereby moving forward in the understanding of important relationships such as the intrinsic strain and chemical activity of the nanoparticles.
2

Imagerie de nanofils uniques par diffraction cohérente des rayons X / Coherent X-ray imaging of single nanowires

Mastropietro, Francesca 04 October 2011 (has links)
L'imagerie par diffraction des rayons X coh´erents (CDI) en condition de Bragg est utilis´e pour ´etudier la d´eformation de nano-objets uniques. Ceci est possible grˆace au d´eveloppement d'optique focalisante, comme les lentilles de Fresnel (FZP), produisant un faisceau sub-micronique coh´erent. Les nanostructure ´etudi´ees sont reconstruite avec des algorithmes d'inversion `a partir de donn´ees de diffraction, sous la forme d'un objet complexe, o`u l'amplitude correspond `a la densit´e ´electronique 3D et la phase correspond `a la projection de la d´eformation de l'objet (par rapport `a un r´eseau cristallin parfait) dans la direction du vecteur de diffraction. Dans ce travail, nous avons ´etudi´e la d´eformation dans des nanofils h´et´erognes (nanofil de GaAs avec une mono-couche de boˆıtes quantiques de InAs) et homog`enes (silicium fortement contraint sur isolant (sSOI)). Lorsqu'un faisceau focalis´e de rayons X est utilis´e, `a la fois l'amplitude et la phase de l'onde incidente doivent ˆetre connu pour une ´etude quantitative. Le faisceau focalis´e utilis´e pendant les exp´eriences a ´et´e recontruit avec la technique CDI, et les effets de cette fonction d'illumination sur l'imagerie de nanofils contraints ont ´et´e ´etudi´es. Mots-cl´es: Imagerie par diffraction x coh´erente, contrainte, nanofils, algorithms d'inversion / The coherent diffraction imaging technique (CDI) in Bragg condition can be used to study strain in single nanowires. This is possible due to the recent development of dedicated focusing optics, e.g. Fresnel Zone Plate (FZP), offering the possibility of focusing x-ray beams to sub-micron sizes while preserving a coherent beam. This technique allows to reconstruct (using phase retrieval algorithms) the studied nanostructure as a complex-valued density map, where the amplitude corresponds to the electronic density and the phase to the displacement of the atoms with respect to a perfect crystalline lattice projected onto the scattering vector. The application of CDI to image the strain into heterogeneous (GaAs nanowire with an insertion of 1 monolayer of quantum dots and InSb nanowire with and insertion of InP) and homogeneous highly stressed nano-structures (strained Silicon-on-Insulator lines) has been studied in this work. When using focused X-ray beams, both the amplitude and of the incoming wavefield must be known for a quantitative reconstruction. CDI has been used to reconstruct the coherent wavefield used during experiments and the effects of this illumination function for the imaging of strained nanowires have been also studied. Keywords: Coherent X-ray diffraction imaging, strain, nanowires, phase retrieval algorithm
3

Étude et applications de l'imagerie sans lentille par diffraction cohérente / Study and applications of lensless imaging by coherent diffraction

Samaan, Julien 14 December 2016 (has links)
Ce mémoire est dédié à l’imagerie par diffraction cohérente. Dans un premier temps, nous présentons la conception et à la mise en oeuvre expérimentale d’un système d’imagerie compact fonctionnant sur ce principe. Il est composé d’unediode UV (λ = 400 nm), d’une caméra CCD, et d’une plate-forme pour placer l’échantillon à observer. Le faisceau cohérent issu de la diode éclaire l’échantillon, et la figure de diffraction est enregistrée par la caméra. La rétro-propagation du champ détecté permet, en principe, de déterminer le profil de l’échantillon. Néanmoins, la phase du champ, perdue lors de la détection, nous contraint à employer desméthodes de « reconstruction de la phase », cette quantité étant nécessaire à l’opération d’inversion. Plusieurs techniques ont été utilisées. L’holographie par Transformée de Fourier, par exemple, est une méthode déterministe qui consiste à utiliser une référence circulaire (ou rectangulaire) gravée à côté de l’échantillon. La phase est encodée dans la figure de diffraction, sous la forme de franges d’interférences issues de l’objet et de la référence. Une simple Transformée de Fourier du signal permet alors de retrouver le profil de l’échantillon. Uneméthode itérative a également été mise en oeuvre, basée sur un jeu de contraintes dans les espaces réel et réciproque. En particulier, l’objet éclairé doit être « isolé », i.e. plus petit que le faisceau incident. Bien que cette méthode soit non-déterministe, nous verrons toutefois qu’elle est plus robuste et permet d’obtenir de meilleures résolutions spatiales qu’en holographie. Cette étude est un point de départ à l’observation d’objets tridimensionnels. Nous présentons une première méthode déterministe, basée sur l’holographie par Transformée de Fourier. Pour ce faire, une « pupille holographique » est utilisée et sert de support à une première reconstruction 2D du champ. Celui-ci est ensuite rétro-propagé vers l’échantillon placé à proximité, afin de réaliser une mise au point entièrement numérique de ce dernier. La contrainte « d’isolation » de l’objet est alors levée par l’utilisation de cette pupille. Avec cette méthode, le champ latéral est toutefoislimité par le diamètre de la pupille. Pour l’observation d’échantillons plus larges, la technique d’holographie « en ligne » a également été exploitée. Elle consiste à éclairer l’objet avec une onde sphérique et à enregistrer les franges d’interférences (ou « hologramme »). Une rétro-propagation est ensuite effectuée pour faire la mise au point sur l’échantillon. Le caractère divergent du faisceau permet de disposer d’un champ latéral de plusieurs millimètres. Le problème de « l’image jumelle », inhérent à cette configuration, est résolu via unalgorithme itératif couplé à la rétro-propagation. Des reconstructions tridimensionnelles ont été effectuées sur divers échantillons, avec cesdeux méthodes — reconstruction pupillaire et holographie en ligne. Pour chacune d’entre elles, des interfaces de reconstruction ont été mises au point et fonctionnent pendant la détection, afin d’observer l’objet en temps réel. Nous disposons alors d’un prototype d’imagerie sans lentille compact et complet. Enfin, nous présentons l’application d’une technique de reconstruction de la phase, appelée LIFT (pour LInearized Focal plane Technique), appliquée à un analyseur de front d’onde Shack-Hartmann. Usuellement, de tels capteurs ont une résolution spatiale limitée par le pas des micro-lentilles : seules les pentes locales (tip/tilt) sont déterminées. Le LIFT consiste à déterminer la phase à l’échelle de chaque micro-lentille, en exploitant le profil du spot correspondant. Des matrices d’interaction sont calculées afin de linéariser la relation entre l’espace réel (micro-lentilles) et l’espace réciproque (matrice CCD), et une boucle itérative permet d’étendre cedomaine de linéarité. Un gain de résolution spatiale de l’ordre de 3, au niveau de chaque micro-lentille, est attendu avec cette technique. / This dissertation is dedicated to coherent diffractive imaging. Firstly, we present the conception and experimental implementation of a compact imaging system, working on this principle. It is made of an UV laser diode (λ = 400 nm), a CCD camera,and a platform to place the sample. The coherent beam coming from the diode illuminates the sample, and the diffraction pattern is recorded by the camera. Back-propagating the detected field should allow, in principle, to derive the sample’s profile. Nevertheless, the field’s phase, lost during the detection, forces us to use “phase retrieval” methods, this quantity being necessary to the inversion process. Several techniques have been used for that purpose. Fourier Transform Holography (FTH), for example, is a deterministic method thatconsists in using a circular reference, closely drilled nearby the sample. The phase is encoded in the diffraction pattern, in the form of interference fringes coming from the object and the reference. Then, a simple inverse Fourier Transform of the signal leads the profile of the sample. An iterative method has also been implemented, based on a set of constraints in the real and reciprocal spaces. In particular, the illuminated object must be “isolated”, i.e. smaller than the incident beam. Although this method is non-deterministic, we will see thatit is more robust and gives better resolutions than the holographic cases. This study is the starting point of three-dimensional imaging. We present a first deterministic method, based on FTH. For this purpose, a “holographic pupil” is used and serves as a support for a first 2D reconstruction of the field. The latter is then back-propagated towards the sample closely placed, in order to realize an entirely numerical focusing on it. The “isolation constraint” is then removed by the use of this pupil. However, with this method, the field of view is limitedby the pupil’s diameter. In order to observe larger samples, the “in-line holography” technique has been exploited as well. It consists in illuminating the object with a spherical wave and recording the interference fringes (or “hologram”). A back-propagation is made after the fact in order to do the focusing on the sample. The divergent nature of the beam allows for reaching several millimeters for the lateral field of view. The “twin image problem”, inherent to this configuration, is solved via an iterative algorithm coupled to the back-propagation process. Three-dimensional reconstructions have been made on varied samples, with these two methods — pupil reconstruction and in-line holography. In both cases, reconstruction interfaces have been implemented and work during the detection, in order to observe the object in real time. We then have a compact and complete lens-less imaging prototype. Finally, we present the application of a phase retrievaltechnique, named LIFT (LInearized Focal plane Technique), applied to a Shack-Hartmann wavefront sensor. Usually, such sensors have a spatial resolution that is limited by the micro-lenses size : only the local slopes, i.e. tip and tilt, are retrieved. The LIFT consists in determining the phase at the scale of each micro-lens, by exploiting the corresponding spot profile. Interaction matrices are calculated in order to linearize the relation between the real space (micro-lenses) and the reciprocal space (CCD chip), and an iterative loop allows for increasing this linearity domain. With this technique, a gain in spatial resolution by a factor 3 is expected.
4

The sensitivity of the EMC algorithm to the light intensity and amount of diffraction patterns in diffraction experiments

Rogvall, Johanna January 2021 (has links)
To understand the function of macromolecules like proteins it helps to know the structure of the molecule. Coherent diffraction imaging is an emerging method that might be used to figure out the structures of macromolecules. In this method diffraction patterns of the macromolecule are recorded by shining light on the molecule from many unknown orientations and detecting the pattern of the diffracted photons. By assembling the diffraction patterns in a specific way and finding the phase of the photons that gave rise to the diffraction patterns, it is theoretically possible to obtain the electronstructure of the molecule and thus the molecular structure. The assembling of several thousand diffraction patterns representing unknown orientations of the molecule is hard to do by hand, but there are several methods that can be used. The EMC (Expand-Maximize-Compress) algorithm is one of those methods. It is an iterative algorithm that tries to create a model describing the Fourier Transform of the electron density of the molecule by maximizing each diffraction patterns fit to the model. This work examines how sensitive the EMC algorithm is to datasets with few diffraction patterns or a low intensity of the light being diffracted by the molecule, for the proteins phytochrome and lysozyme. The result of the work could be used to make sure enough data in collected in real experiments. Diffraction patterns simulated with the program Condor is used in this work, instead of diffraction patterns from real experiments.EMC finds the correct model when the data set contains about 1/3 fewer photons for the smaller more symmetrical molecule lysozyme than it does for phytochrome. This might be because the shapes in lysozymes diffraction patterns are larger than in phyochrome’s patterns. For phytochrome the EMC algorithm assembled the diffraction patterns correctly, with fewest photons for the light intensity 0.764 J/μm2 and 1250 diffraction patterns. For lysozyme it was with an intensity 1.910 J/μm2 and 1425 diffraction patterns. More investigation of the data is needed to understand what factors that affect the EMC algorithms ability to assemble the diffraction patterns correctly. / För att förstå makromolekylers kemiska eller biologiska funktion so underlättar det om man känner till molekylens kemiska struktur. Med den nya tekniken “coherent diffraction imaging” ska det vara möjligt att lista ut makromolekylers struktur. I denna teknik detekterar man diffraktionsmönster av molekylen genom att belysa molekylen med ljus från många olika okända vinklar and registrera mönstret som skapas av det diffrakterade ljuset. Genom att sätta ihop alla dessa diffraktionsmönster på rätt sätt och sen återskapa fasen för ljuset i diffraktionsmönstret så kan man generera molekylens elektronstruktur och från elektronstrukturen kan man få tag i molekylens struktur. Att sätta ihop tio tusentals diffraktionsmönster med okända vinklar på rätt sätt är väldigt svårt att göra, men det finns flera olika metoder som kan användas. EMC (Expand-Maximize-Compress) är en sådan metod. EMC är en iterativ algoritm som skapar en modell av (Fourier transformen av) molekylens elektronstruktur genom att maximera hur bra diffraktionsmönstren passar med modellen. Detta arbete utreder hur bra EMC algoritmen är på att hitta rätt (Fourier transform av) elektronstruktur när väldigt få diffraktionsmönster används eller när intensiteten på ljuset som sprids av molekylen är lågt. Programmet Condor används för att generera teoretiska diffraktionsmönster för de 2 molekylerna lysozym och fytokrom. EMC används sedan med olika uppsättningar av intensitet och antal diffraktionsmönster för att skapa en modell av elektronstrukturen. EMC behövde ca 1/3 färre antal fotoner i sin modell för att hittar den rätta modellen av elektronstrukturen för den lilla symmetriskt formade molekylen lysozym än för fytokrom. Att det är lättare för EMC algoritmen att hitta den korrekta modellen för lysozym än fytokrom kan bero på att lysozyms diffraktionsmönster har större former/features eller på lysozyms storlek och form. EMC körningen som behövde minst antal fotoner för att hitta den korrekta elektronstrukturen för fytokrom hade intensiteten 0,764 J/μm2 på det inkommande ljuset och behövde 1250 diffraktionsmönster. För lysozym behövdes det 1,910 J/μm2 och 1425 diffraktionsmönster för att EMC algoritmen skulle hitta rätt modell av elektronstrukturen.
5

A Near-Infrared Diffraction Radiation Spectrometer for MHz Repetition Rate Electron Bunch Diagnostics at the European XFEL

Fahlström, Simon January 2019 (has links)
We have built a spectrometer to investigate the Near-Infrared (NIR) range of this radiation, which is used for bunch diagnostics at the European X-ray Free-Electron Laser. This could give information on the development of microbunching, periodic features in the longitudinal charge profile of the bunches which have a negative impact on the operation of the facility. In general it offers an ability to investigate the influences of the laser heater, the compression, and other factors that affect the structure of the bunches. The CDR is generated 1934 m after the injector, at full acceleration. The spectrometer is based around the KALYPSO detector system, able to read out from a 256 pixel linear array detector at MHz frequencies, making it possible to obtain single bunch readings during current user operation of the facility, at 1.1 MHz. KALYPSO has an InGaAs sensor, sensitive in the range 0.9 – 1.7 μm. A 40 mm N-SF11 equilateral prism is used for dispersion. First measurements have been taken, and CDR has been detected. The spectrometer needs further calibration and resolution was lacking, but it can offer insight in to relative changes, and bunch-to and can be used as for fingerprinting the beam. A reduction in signal in the sensitive range and a skew towards longer wavelengths was seen when going from uncompressed to compressed beam. When varying the power of the laser heater the behavior varied from run to run, with changing machine settings. In some cases the CDR was attenuated, while FEL intensity initially increased, until the induced energy spread from the laser heater was large enough to inhibit the FEL process. Another, less expected, behaviour was also observed, where the initially low CDR intensity at first increased, while FEL intensity stayed the same, before it then followed the same pattern as in the first case.
6

Tabletop Extreme-Ultraviolet Source Using High Harmonic Generation for Polarization Sensitive Imaging

Buckway, Taylor Jordan 12 May 2022 (has links)
We are developing a tabletop extreme-ultraviolet source using high harmonic generation at Brigham Young University. The thesis goes over the theory of high harmonic generation using the three-step model. This tabletop source was designed for probing magnetic domains of iron nanoparticles. We present optimization of the 42 eV and 52 eV harmonics through phase matching. Phase matching consists of tuning the intensity of the IR beam and pressure of the gas medium. The target gas medium used for this thesis is argon. The 42 eV harmonic was optimized to 8.2 billion photons per second. This was used with a 1500 mm focal-length lens, 15 mm medium length, laser power of 1.53 Watts, and a pressure of 12 Torr of argon gas. The 52 eV harmonic was optimized to 1.5 billion photons per second with a 1500 mm focal-length lens, 20 mm medium length, laser power of 3.29 W, and 14.9 Torr of argon gas. There are two designs for selection of harmonics: 1) a tunable design consisting of a toroidal mirror and flat diffraction grating and 2) a set of normal-incidence extreme-ultraviolet mirrors designed for 42 or 52 eV photons. Magnetic imaging uses x-ray magnetic circular dichroism to obtain magnetic contrast and use it to visualize magnetic nanosystems. Therefore, the high harmonic source also needs to generate circularly polarized light. Generating circularly polarized high harmonics is possible with a bichromatic beam. This is achieved using an apparatus called the MAZEL-TOV designed by Oren Cohen’s group at Technion University in Israel. The MAZEL-TOV consists of a BBO crystal for second harmonic generation, a pair of pulse delay compensation plates, and a quarter-wave plate. These optics are placed inline with the laser beam. We have successfully optimized the circularly polarized extreme-ultraviolet harmonics with the MAZEL-TOV. A spectrometer was made to calibrate the harmonics in the MAZEL-TOV spectrum. The tabletop source was then used to demonstrated coherent diffraction imaging of two pinholes.
7

Imagerie nanométrique ultra-rapide par diffraction cohérente de rayonnement XUV produit par génération d'harmoniques d'ordre élevés / Ultrafast Nanoscale Imaging Using Coherent Diffraction of XUV Produced HHG

Cassin, Rémy 21 December 2017 (has links)
L'objectif de ce mémoire est dedévelopper de nouvelles méthodes d'imageriesans lentille en simple tir 2D et 3D avec dessources harmoniques XUV. Un intérêt particulierest porté aux techniques d'imageries permettantl'imagerie des objets biologiques et de phase.Dans un premier temps, on introduit la théorie del'imagerie dans lentille et on détaille lesméthodes utilisées au cours de cette thèse pourreconstruire le champ diffracté par l'objet quel'on souhaite imager. Les techniques d'imageriessont séparées en deux catégories : itératifs etholographiques. On discute des conditionsexpérimentales nécessaires à la reconstruction del'image de l'objet et on compare les avantagesrespectifs des deux types de méthodes. Puis, ondétaille les aspects expérimentaux du faisceauXUV obtenu par HHG et on couvre brièvementla théorie associée à ce processus. La sectionsuivante traite des paramètres et des techniquesde traitement des données influant sur la qualitéde l'image reconstruite en imagerie sans lentille.On montre comment améliorer lesreconstructions HERALDO dans un régime defaible flux de photons. On présente ensuite lesrésultats d'une technique de caractérisationcomplète de la cohérence spatiale d’un faisceauXUV en simple tir. Cette dernière est unparamètre critique de l'imagerie sans lentille. Al'aide d'un tableau non redondant de référencesponctuelles, on mesure la cohérence spatialepour chaque distance entre les références, sansaucune mesure du profil spatial du faisceau. Onmontre que la distribution de la cohérence estgaussienne et que son diamètre dépend desconditions de génération du faisceauharmonique. On étudie aussi quantitativementcomment l'accumulation de plusieurs tirs dediffraction diminue la cohérence apparente dufaisceau. Une expérience d'imagerie d'objets dephase avec une source harmonique pouvant êtreappliquée à des objets biologiques est ensuiteprésentée.A notre connaissance c'est la premièrereconstruction par méthode CDI d'objets dephase avec une source harmonique. La suite dumanuscrit présente les résultats de deuxexpériences visant à réaliser de l'imagerie 3D àl'échelle nanométrique avec une sourceharmonique. Tout d’abord, on présente unetechnique d'imagerie 3D simple tir. C'est lapremière expérience permettant unereconstruction 3D à partir d'une seuleacquisition, avec une résolution spatialenanométrique et une résolution temporellefemtoseconde, sans utiliser de connaissances apriori sur l'objet étudié. Cette technique possèdeun vaste spectre d'application, particulièrementpour l'étude structurelle d'échantillonsbiologiques sensibles aux dégâts d'irradiation.De plus, cette technique peut être facilementapplicable à des FELs et des synchrontrons pourobtenir de meilleures résolutions. La deuxièmeexpérience d'imagerie 3D est une preuve deconcept validant la faisabilité de lacryptomographie avec une source harmonique.Pour reconstruire le volume 3D de l'échantillon,la cryptotomographie utilise des figures dediffraction qui sont acquises pour desorientations de l'échantillon inconnues. Lerégime de faible flux dans lequel on se place nouspermet de simuler les paramètres d'une sourceharmonique fonctionnant dans la fenêtre de l'eau.On conclut que, le niveau du signal de diffractionest suffisant pour pouvoir identifier l'orientationde l'objet à partir des figures de diffractionenregistrées, dans des conditions expérimentalesoptimisées. Ainsi, avec suffisamment de figuresde diffraction enregistrées et assez d'orientationsde l'objet, on peut reconstruire le volume 3D del'objet. Ces résultats impliquent qu'uneexpérience de cryptotomographie d'objetsbiologiques avec une source harmoniquefonctionnant dans la fenêtre de l'eau seraitréalisable. / The aim of this dissertation is todevelop new lensless single shot imagingtechnique in 2D and 3D with XUV harmonicsources which can be applied to study biologicalobjects and phase objects. Firstly, we introducethe theory underlying lensless imagingtechniques and we describe the methods usedduring this thesis to reconstruct the light fielddiffracted by the studied object. The imagingtechniques are split in two categories: iterativeand holographic. The iterative methodsreconstruct the phase of the diffracted wavefront using constraints in the Fourier space andthe reel space. With the holographic techniques,the phase is encoded directly in the interferencefringes between the reference and the objectwithin the diffraction pattern. We discuss theexperimental parameters required to achieve animage reconstruction and we compare therespective advantages of the two types ofmethod. Then, we describe the experimentalparameters of the XUV beam produced by highharmonic generation (HHG) and we brieflyexplain the theory of the HHG. The next sectiondiscusses the parameters the quality of thereconstructed image. We show how to improvethe resolution and the signal to noise ratio usingthe HERALDO technique in the low fluxregime.We then show the result of a new technique forthe single shot characterization of the spatialcoherence of XUV beams. Indeed, the spatialcoherence is a critical parameter for coherentdiffractive imaging techniques. Using a NRA ofreference holes, we measure the spatialcoherence for each distance between each pairof holes, without the knowledge of the intensitydistribution on the sample. We show that thespatial coherence has a gaussian distribution andthat its diameter varies according to thegeneration parameters of the harmonic beam.We also study quantitatively the effect of multishotsaccumulation of the diffraction pattern onthe apparent coherence of the beam. We alsoshow the result of phase object imaging usingcoherent diffractive imaging with a harmonicsource. To our knowledge, this if the first timesuch result has been achieved. The rest of thedissertation present new lensless imaging 3Dtechniques using harmonic sources. The first ofthe last two experiments shown is a lenslesssingle shot stereo 3D technique. It is the first oneallowing a 3D reconstruction from a singleacquisition, with a nanometer spatial resolutionand a femtosecond temporal resolution, withoutusing \textit{a priori} knowledge of the samplestudied. This method has a vast spectrum ofapplication and is particularly interesting for thestructural study of biological sample sensitive toradiation damage and for the study of nonreversibledynamical phenomena in 3D.Furthermore, this can easily be implemented inFELs and synchrotrons to reach even betterspatial resolution. The second 3D experimentshown in this thesis is a proof of concept ofcryptotomography using a high harmonic sourcein a low flux regime. To reconstruct the 3Dvolume of the sample, cryptotomographie usesdiffraction pattern acquired for unknown sampleorientations and therefore non-classified. Thelow flux regime used here simulate the flux of aharmonic source generated in the water window.We conclude from this experiment that, with theproper experimental conditions, the diffractionsignal is sufficient to allow the classification byorientation of the diffraction patterns. Withenough diffraction pattern and angles of thesample recorded, we can achieve a 3Dreconstruction of the sample. This result impliesthat the cryptotomography of biological objectsusing a water window harmonic source ispossible.
8

Effects of Ultrafast Ionization in X-ray Coherent Diffraction Imaging / Effekter av Ultrasnabb Jonisering i Röntgen Koherent Diffraktionsavbildning

Sehati, Arezu January 2023 (has links)
Koherent Diffraktionsavbildning med en intensiv röntgenpuls från en Frielektronlaser har möjliggjort strukturbestämning av isolerade nanopartiklar som inte går att studera med hjälp av konventionella metoder, så som elektronmikroskopi. En mycket kort pulslängd tillsammans med spridningssignalens beroende av objektets elektroniska struktur medför också möjligheten att studera inducerad ultrasnabb dynamik med denna teknik. I detta projekt studerades joniseringspåverkan av Xe hos Xe-Ar core-shell-nanokluster. Enligt teorin har neutral Xe lägre spridningstvärsnitt under dess 3d-resonans än det motsvarande för fotonenergier över 3d-resonansen. Därför var en hög kontrast i klustren förväntad vid energier över dess 3d-resonans. I stället observerades mörkare regioner liknande hål i rekonstruktioner från de experimentella resultaten vid energier över 3d-resonansen hos Xe. En möjlig förklaring var jonisering av neutral Xe. För att undersöka detta skapades 3D modeller av Xe-Ar nanokluster för att simulera den interaktionen mellan intensiva röntgenpulser och nanokluster. Diffraktionsmönstren som genererades med hjälp av 3D-modellerna användes sedan för att utföra Iterativ fasrekonstruktion och rekonstruera partikeldensiteten. Brytningsindex av neutral Xe och de första tio jontillstånden hos Xe beräknades med hjälp av en modell konstruerad i detta projekt, kallad för step-model. Följaktligen introducerades samtliga jontillstånden hos Xe från 0 till 10 in i 3D modeller av Xe-Ar nanoklustren med brytningsindexen av jontillstånden uppskattade med hjälp av Kramers-Kronig-relationerna. Här antogs det att samtidigt som resonansen för varje Xe-jon förflyttas visar 𝛽 (det vill säga den imaginära komponenten i det komplexa brytningsindexet) som en funktion av fotonenergin, ett icke-monotoniskt beteende med en förändring i fotonenergin. Simuleringsresultaten erhållna med hjälp av Kramers-Kronig-relationerna visade en avtagande trend för 𝛽 i Xe-joner med en laddning> 4+ till skillnad från en ökning i 𝛽 för joner med en laddning <4+ relativt dess motsvarande för neutral Xe. Denna metod ansågs tillräcklig för att användas som en första approximation. Dessa resultat visade att ju mer Xe joniseras (och därför minskar 𝛽) desto mer transparenta blir Xe-jonerna under en laserpuls och därför ser de mörkare ut jämfört med Ar som har sin resonans långt ifrån fotonenergierna relevanta för detta projekt (660–760 eV). Vidare simulerades temporära förändringar i Xe-jonpopulationer för att bekräfta de erhållna simuleringsresultaten via step-model. En massiv energideposition då den intensiva röntgenpulsen träffar Xe-kärnorna initierar en serie av joniseringsmekanismer under de första få femtosekunderna av pulsen. Simuleringar för de jonpopulationer som uppstår och försvinner under förloppet av en 100 femtosekunder-lång röntgenpuls visade att jontillstånd mellan 1+ och 10+ är redan förbrukade efter några få femtosekunder vid 1016 W/cm2. Vid slutet av pulsen observerades endast högt laddade Xe-joner (upp till 35+). Den slutsats som drogs var därför att mörkare regioner som liknade hål och observerades i rekonstruktioner från experimentella data var en konsekvens av en förflyttning av resonansen hos de högt laddade Xe-joner (>4+) relativt dess motsvarande i en neutral Xe så att deras spridning minskar. / Coherent Diffraction Imaging with intense x-ray pulses from X-ray Free-Electron Lasers has enabled structure determination of isolated nanoparticles, that cannot be studied with conventional methods, such as electron microscopy. The very short pulse durations and the intrinsic dependence of the scattering signal on the electronic structure of the scattering object also allow studying ultrafast light-induced dynamics with this technique. In this project, the ionization impact of Xe on Xe-Ar core-shell nanoclusters was studied. Theory predicts that neutral Xe has a lower scattering cross-section below its 3d resonance than that at photon energies above its 3d resonance. Therefore, a high contrast in clusters above the neutral Xe’s 3d resonance is expected. However, in the experimental data, unusual dark features resembling holes were observed at energies above Xe’s 3d resonance. As possible explanation, ionization of neutral Xe was suggested. To investigate this, 3D models of Xe-Ar nanoclusters were created to simulate the interaction of intense x-ray pulses and nanoclusters. The diffraction patterns generated by these 3D models were used to perform Iterative Phase Retrieval to reconstruct the particle densities. The refractive indices of neutral Xe and Xe’s first ten ionic states were computed using a model designed in this project, called the step-model. Hence, each and every ionic state of Xe from 0 to 10 were introduced into the 3D models of the Xe-Ar nanoclusters with refractive indices of the ionic states estimated based on the Kramers-Kronig relations. Here, it was assumed that as the resonance is shifting for every ionic state of Xe, 𝛽 (i.e the imaginary component of the complex refractive index) as a function of photon energy shows a nonmonotonic behavior as the photon energy is varied. The simulation results by Kramers-Kronig relations showed a decrease in 𝛽 for ionic states > 4+ in contrast to an increase in 𝛽 for ions with charges < 4+ relative to that of neutral Xe. This approach was sufficient to be used as a first approximation. The results showed that Xe ions become more transparent to the laser pulse as their charge increases (and 𝛽 thereby decreases) and therefore they appear darker than Ar, which has its resonance far away from photon energies relevant for this project (660–760 eV). Furthermore, temporal changes in ionic populations of Xe were simulated to confirm the simulation results obtained by the step-model. The massive energy deposition upon interaction with the intense laser pulse launches a series of ionization events in the Xe cores during the first few fs of the x-ray pulse. The simulation of ionic populations emerging and depleting during the 100-fs-long 1016 W/cm2 x-ray pulse showed that ionic states 1+ to 10+ are depleted already after a few fs. By the end of the pulse, only highly charged (up to 35+) Xe ions are observed. Therefore, it was concluded that the dark features resembling holes in reconstructions from the experimental data were a consequence of a shift in the resonance of highly charged Xe ions (>4+) relative to that of neutral Xe so that their scattering decreases.
9

Interfacial studies of Pt and Cu single-crystal electrodes modified by transition metal deposition

Sarabia, Francisco J. 05 February 2021 (has links)
El conocimiento de las características interfaciales es de suma importancia para poder desarrollar materiales que sean capaces de dar lugar a reacciones electrocatalíticas eficientes. Por esta razón, en esta tesis se muestran diferentes estudios interfaciales sobre superficies monocristalinas de platino y cobre en diferentes electrolitos. Además se estudian las características de la interfase electrodoldisolución con superficies de platino modificadas con adátomos de hierro, cobalto y níquel. Para ello, se han empleado las técnicas de voltametría cíclica, espectroscopía infrarroja con transformada de Fourier, desplazamiento de carga con CO y salto de temperatura inducido por láser. Los resultados muestran cómo varía el campo eléctrico interfacial disminuye al aumentar el recubrimiento de hierro y níquel en la superficie de platino. Este efecto tiene un gran impacto en la reacción de evolución de hidrógeno, ya que la mejora electrocatalítica de esta reacción está relacionada con la energía de reorganización de las moléculas de agua, la cual, depende de la fortaleza del campo eléctrico interfacial. Los estudios realizados en medio alcalino para las diferentes superficies de cobre y platino sin modificar muestran una correlación entre el potencial de máxima entropía y las funciones de trabajo para cada una de las diferentes orientaciones atómicas superficiales. Por otro lado, debido a la aplicabilidad de las nanopartículas en los sistemas reales de conversión de energía, se realizaron experimentos de sincrotrón empleando la técnica de Bragg coherent difraction imaging con el objetivo de estudiar el deterioro de las nanopartículas en condiciones operando.
10

Imagerie nanométrique ultra-rapide par diffraction cohérente de rayonnement extrême-UV produit par génération d'harmoniques d'ordre élevé / Ultrafast nanometers scale coherent diffractive imaging with extreme-UV light from high harmonics generation beamline

Gauthier, David 07 February 2012 (has links)
Ce manuscrit présente des expériences d’imagerie par diffraction réalisées en utilisant une source de rayonnement cohérent basée sur la génération d’harmoniques d’ordre élevé d’un laser Ti:Sa. Elles démontrent que cette source extrême-UV de laboratoire produit un nombre suffisant de photons par impulsion pour enregistrer une figure de diffraction d’objets tests en « simple tirs ». Le signal ainsi enregistré permet l’obtention d’une image de l’objet avec une résolution d’une centaine de nanomètres. Deux schémas sont utilisés pour reconstruire l’objet : le premier utilise un algorithme itératif de reconstruction de la phase perdue pendant la détection de la figure de diffraction ; le second utilise une configuration holographique par transformée de Fourier. Les travaux réalisés comportent deux parties. La première concerne l’optimisation de la source harmonique et inclut une étude expérimentale d’un dispositif de filtrage spatial du faisceau laser de génération par propagation dans une fibre creuse. La seconde partie présente les expériences d’imagerie par diffraction, et notamment une démonstration du schéma holographique HERALDO qui est une extension de l’holographie par transformée de Fourier à des références en forme de polygones. L’utilisation de ces références « étendues » a pour avantage d’optimiser l’enregistrement holographique tout en conservant une reconstruction directe et sans ambigüité de l’objet. Une analyse signal-sur-bruit ainsi qu’une comparaison des reconstructions d’hologramme pour différentes formes de références sont effectuées. / This manuscript presents diffraction imaging experiments performed using a source of coherent radiation based on high order harmonics generation of a Ti:Sa laser. They demonstrate that this laboratory size XUV source produces a number of photons per pulse sufficient to record the diffraction pattern of test objects in « single shot ». The signal thus recorded allows obtaining an image of the object with a resolution of around 100 nanometers. Two schemes are used to reconstruct the object: the first one uses an iterative algorithm to retrieve the phase lost during the detection of the diffraction pattern; the second uses a configuration of Fourier transform holography. The work presented here is separated in two parts. The first one concerns the optimization of the harmonic source, including an experimental study of a spatial filtering device for laser beams by propagation in a hollow core fiber. The second part deals with the diffraction imaging experiments. In particular, I present a demonstration of the holographic scheme HERALDO, which is an extension of the Fourier transform holography with polygonal references. The use of these « extended » references allows the optimization of the holographic recording while maintaining a direct and non-ambiguous reconstruction of the object. An analysis of signal-to-noise ratio and a comparison of hologram reconstructions for different types of references are performed.

Page generated in 0.1251 seconds