• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 145
  • 41
  • 40
  • 27
  • 23
  • 16
  • 6
  • 5
  • 4
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 385
  • 385
  • 122
  • 109
  • 102
  • 73
  • 68
  • 47
  • 45
  • 43
  • 42
  • 38
  • 37
  • 34
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
231

Application of knowledge-based fuzzy inference system on high voltage transmission line maintenance

Mohd Noor, Mohd Junaizee January 2004 (has links)
A majority of utilities conduct maintenance of transmission line components based on the results of routine visual inspection. The inspection is normally done by inspectors who detect defects by visually checking transmission line components either from the air (in helicopters), from the ground (by using high-powered binoculars) or from the top of the structure (by climbing the structure). The main problems with visual inspection of transmission lines are that the determination of the defects varies depending on the inspectors' knowledge and experience and that the defects are often reported qualitatively using vague and linguistic terms such as "medium crack", "heavy rust", "small deflection". As a result of these drawbacks, there is a large variance and inconsistency in defect reporting (which, in time, makes it difficult for the utility to monitor the condition of the components) leading to ineffective or wrong maintenance decisions. The use of inspection guides has not been able to fully address these uncertainties. This thesis reports on the application of a visual inspection methodology that is aimed at addressing the above-mentioned problems. A knowledge-based Fuzzy Inference System (FIS) is designed using Matlab's Fuzzy Logic Toolbox as part of the methodology and its application is demonstrated on utility visual inspection practice of porcelain cap and pin insulators. The FIS consists of expert-specified input membership functions (representing various insulator defect levels), output membership functions (indicating the overall conditions of the insulator) and IF-THEN rules. Consistency in the inspection results is achieved because the condition of the insulator is inferred using the same knowledge-base in the FIS rather than by individual inspectors. The output of the FIS is also used in a mathematical model that is developed to suggest appropriate component replacement date. It is hoped that the methodology that is introduced in this research will help utilities achieve better maintenance management of transmission line assets.
232

Corona ions from high voltage powerlines : production, effect on ambient particles, DC electric field and implications on human exposure studies

Fatokun, Folasade Okedoyin January 2008 (has links)
Powerlines are important in the process of electricity transmission and distribution (T & D) and their essential role in transmitting electricity from the large generating stations to the final consumers cannot be over emphasized. Over the years, an increase in the demand for electrical energy (electricity) has led to the construction and inevitable use of high transmission voltage, sub-transmission voltage and distribution voltage power conducting lines, for the electricity T & D process. Along with this essential role, electricity conductors can also give rise to some electrically related effects such as interference with telecommunication circuits, electric shocks, electromagnetic fields, audible noise, corona ion discharges, etc. The presence of powerline generated corona ions in any ambient air environment can be associated with the local modification of the earth’s natural dc electric field (e-field), while the interactions between these ions and other airborne aerosol particles can be associated with the presence of charged aerosol particles in the environment of the corona ion emitting lines. When considering all the studies conducted to date on the possible direct and indirect effects of high voltage powerlines (HVPLs), of significant interest are those suggesting links between powerlines and some adverse human health effects – with such health effects alleged to be strongest amongst populations directly exposed to HVPLs. However, despite the numerous studies conducted on HVPLs, to date a lack of proper scientific understanding still exist in terms of the physical characterization of the electrical environment surrounding real-world HVPLs - mostly in terms of the entire dynamics of ions and charged particles, as well as the possible links/associations between the different parameters that characterize these electrical environments. Yet, gaining a sound understanding about the electrical environment surrounding energized real-world HVPLs is imperative for the accurate assessment of any possible human exposure or health effects that may be associated with powerlines. The research work presented in this thesis was motivated by the existing gaps in scientific understanding of the possible association between corona ions generated by real-world HVPLs and the production of ambient charged aerosol particles. The aim of this study was to supply some much needed scientific knowledge about the characteristics of the electrical environment surrounding real-world energized HVPLs. This was achieved by investigating the possible effects of corona ions generated by real-world overhead HVPLs on ambient aerosol particle number concentration level, ambient aerosol particle charge concentration level, ambient ion concentration level and the magnitude of the local vertical dc e-field; while also taking into consideration the possible effect of complex meteorological factors (such as temperature, pressure, wind speed wind direction, solar radiation and humidity) on the instantaneous value of these measured parameters, at different powerline sites. The existence of possible associations or links between these various parameters measured in the proximity of the powerlines was statistically investigated using simple linear regression, correlation and multivariate (principal component, factor, classification and regression tree-CART) analysis. The strength of the regression was tested with coefficient of determinations R2, while statistical significance was asserted at the 95 % confidence level. For the powerline sites investigated in this study, both positive and negative polarities of ions were found to be present in the ambient air environment. The presence of these ions was associated with perturbations in the local vertical dc e-field, increased net ambient ion concentrations and net particle charge concentration levels. The mean net ion concentration levels (with a range of 4922 ions cm-3 to -300 ions cm-3) in the ambient environment of these powerlines, were in excess of what was measured in a typical outdoor air (i.e -400 ions cm-3). The mean net particle charge concentration levels (1469 ions cm-3 to -1100 ions cm-3) near the powerlines were also found to be statistically significantly higher than what was obtained for a mechanically ventilated indoor room (-84 ± 49 ions cm-3) and a typical urban outdoor air (-486 ± 34 ions cm-3). In spite of all these measured differences however, the study also indicated that ambient ion concentration as well as its associated effects on ambient particle charge concentration and e-field perturbations gradually decreased with increase in distance from the powerlines. This observed trend provided the physical evidence of the localized effect of real-world HVPL generated corona ions. Particle number concentration levels remained constant (in the order of 103 particles cm-3) irrespective of the powerline site or the sampling distance from the lines. A close observation of the output signals of the sampling instruments used in this study consistently revealed large fluctuations in the instantaneous value of all the measured electrical parameters (i.e. non-periodic extremely high and low negative and positive polarities of ions/charged particles and e-field perturbations was recorded). Although the reason for these observed fluctuations is not particularly known at this stage, and hence in need of further investigations, it is however being hypothesized that, since these fluctuations appear to be characteristic of the highly charged environment surrounding corona ion emitting electrical infrastructures, they may be suggestive of the possibility that the release of corona ions by ac lines are not necessarily in the form of a continuous flow of ions. The results also showed that statistically significant correlations (R2 = 74 %, P < 0.05) exists between the instantaneous values of the ground-level ambient ion and the ground-level ambient particle charge concentration. This correlation is an indication of the strong relationship/association that exists between these two parameters. Lower correlations (R2 = 3.4 % to 9 %, P < 0.05) were however found to exist between the instantaneous values of the vertical dc e-field and the ground-level ambient particle charge concentration. These suggest that e-field measurements alone may not necessarily be a true indication of the ground-level ambient ion and particle charge concentration levels. Similarly, low statistical correlations (R2 = 0.2 % to 1.0 %, P < 0.05) were also found to exist between the instantaneous values of ambient aerosol particle charge concentration and ambient ultrafine (0.02 to 1 μm sized) aerosol particle number concentration. This low level of correlations suggests that the source contribution of aerosol particle charge and aerosol particle number concentration into the ambient air environment of the HVPLs were different. In terms of the implication of human exposure to charged aerosol particles, the results obtained from this study suggests that amongst other factors, exposure to the dynamic mixture of ions and charged particles is a function of : (a) distance from the powerlines; (b) concentration of ions generated by the powerlines; and (c) meteorology - wind turbulence and dispersal rate. In addition to all its significant findings, during this research, a novel measurement approach that can be used in future studies for the simultaneous monitoring of the various parameters characterizing the physical environment of different ion/charged particle emission sources (such as high voltage powerlines, electricity substations, industrial chimney stack, motor vehicle exhaust, etc.) was developed and validated. However, in spite of these significant findings, there is still a need for other future and more comprehensive studies to be carried out on this topic in order to extend the scientific contributions of in this research work.
233

Corona discharges on the surfaces of high voltage composite insulators

Hinde, David Derek January 2009 (has links)
The degradation of high voltage electrical insulation is a prime factor that can significantly influence the reliability performance and the costs of maintaining high voltage electricity networks. Little information is known about the system of localized degradation from corona discharges on the relatively new silicone rubber sheathed composite insulators that are now being widely used in high voltage applications. This current work focuses on the fundamental principles of electrical corona discharge phenomena to provide further insights to where damaging surface discharges may localize and examines how these discharges may degrade the silicone rubber material. Although water drop corona has been identified by many authors as a major cause of deterioration of silicone rubber high voltage insulation until now no thorough studies have been made of this phenomenon. Results from systematic measurements taken using modern digital instrumentation to simultaneously record the discharge current pulses and visible images associated with corona discharges from between metal electrodes, metal electrodes and water drops, and between waters drops on the surface of silicone rubber insulation, using a range of 50 Hz voltages are inter compared. Visual images of wet electrodes show how water drops can play a part in encouraging flashover, and the first reproducible visual images of water drop corona at the triple junction of water air and silicone rubber insulation are presented. A study of the atomic emission spectra of the corona produced by the discharge from its onset up to and including spark-over, using a high resolution digital spectrometer with a fiber optic probe, provides further understanding of the roles of the active species of atoms and molecules produced by the discharge that may be responsible for not only for chemical changes of insulator surfaces, but may also contribute to the degradation of the metal fittings that support the high voltage insulators. Examples of real insulators and further work specific to the electrical power industry are discussed. A new design concept to prevent/reduce the damaging effects of water drop corona is also presented.
234

Μελέτη σφαλμάτων σε μετασχηματιστές υψηλής τάσης με αυτόματο μεταγωγέα τάσης (TAP changer)

Παππά, Αγγελική 19 January 2011 (has links)
Στην παρούσα διπλωματική εργασία γίνεται αναλυτική περιγραφή της λειτουργίας της διάταξης του Μεταγωγέα Τάσης Υπό Φορτίο ενός μετασχηματιστή υψηλής τάσης 150 kV/ 21 kV. Επίσης, περιγράφονται και αναλύονται σφάλματα που εμφανίζονται σε μετασχηματιστές με Μεταγωγέα Τάσης Υπό Φορτίο με χρήση εμπειρικών δεδομένων από την εταιρεία Δ.Ε.Η. Α.Ε. και τη θεωρητική ανάλυση και εξήγησή τους μέσα από βιβλιογραφική μελέτη . Συγκεκριμένα, περιγράφονται τα αίτια που δημιουργούν αυτά τα σφάλματα, τα συμπτώματα που εμφανίζονται στο μετασχηματιστή και το μεταγωγέα τάσης , οι επιπτώσεις των σφαλμάτων αυτών στο μετασχηματιστή και τη διάταξη του μεταγωγέα τάσης . Επιπλέον, γίνεται αναφορά στα συστήματα προστασίας που διαθέτει ο μετασχηματιστής και ο μεταγωγέας τάσης προκειμένου να προστατευθεί από τις επιπτώσεις αυτών των σφαλμάτων. Στη συνέχεια, μελετάται συγκεκριμένο σφάλμα, που παρουσιάστηκε στο Μ/Σ 150 kV/21 kV Νο1 του Υ/Σ 150 kV/21 kV των Ελληνικών Ναυπηγείων Σκαραμαγκά, και καταγράφεται η αντιμετώπισή του βήμα προς βήμα σε συνεργασία με την εταιρεία ΠΑΡΑΛΟΣ ΤΕΧΝΙΚΗ Α.Ε., στην οποία ανατέθηκε η επίλυση του σφάλματος. Τέλος, μέσα από την προσομοίωση ενός Μ/Σ υψηλής τάσης με μεταγωγέα τάσης υπό φορτίο με χρήση του λογισμικού πακέτου MatLab/SimuLink κατανοούμε σε βάθος τη λειτουργία του μεταγωγέα τάσης υπό φορτίο. Η προσομοίωση περιλαμβάνει την εφαρμογή διαταραχών της τάσης του δικτύου στο Μ/Σ στην περίπτωση ορθής και εσφαλμένης λειτουργίας του οργάνου του ρυθμιστή τάσης, καθώς η εσφαλμένη λειτουργία του ρυθμιστή τάσης ήταν και η αιτία του σφάλματος στο Μ/Σ του Υ/Σ 150 kV/21 kV των Ελληνικών Ναυπηγείων Σκαραμαγκά. / The particular project deals with the detailed description of the layout and the operation of the on load tap changer belonging to a transformer of high tension 150kV/21 kV. Furthermore, it describes and analyzes faults that occurs to transformers with on load tap changer using empirical data from DEI S.A. (Public Power Corporation) as well as theoretical analysis and explanation based on bibliography. In particular, there are described the reasons behind these faults , the symptoms that appear to the transformer and the tap changer and the consequences to the transformer and the layout of the tap changer. Moreover, there is reference to the protection systems that the transformer and the tap changer have in order to be protected from the consequences of the faults. Further on, a particular troubleshooting is studied that occurred at the transformer 150 kV/21 kV no1 of the high voltage substation 150 kV/21 kV at the Hellenic Shipyards of Skaramagas and its handling is reported step by step in association with PARALOS TECHNICAL S.A. , the company which was assigned to solve the troubleshooting. Finally, the operation of the on load tap changer is studied in depth through simulation of a high voltage transformer with on load tap changer using MatLab/SimuLink software package. The simulation includes the application of voltage variations at the transformer, occurred to the high voltage network in the case of orderly or disorderly operation of the voltage regulator, as the faulty operation of the voltage regulator was the reason behind the troubleshooting of the transformer of the substation of 150 kV/ 21 kV at the Hellenic Shipyards of Skaramagas.
235

Διερεύνηση συμπεριφοράς μονωτήρων υψηλής τάσης μέσω μετρήσεων του ρεύματος διαρροής

Πυλαρινός, Διονύσιος 31 August 2012 (has links)
Η παρακολούθηση του ρεύματος διαρροής, και ειδικά της κυματομορφής του, είναι μια ευρύτατα διαδεδομένη τεχνική για την παρακολούθηση της επιφανειακής δραστηριότητας και κατάστασης των μονωτήρων υψηλής τάσης. Η παρακολούθηση στο πεδίο είναι απαραίτητη για να υπάρξει μια πιστή καταγραφή της δραστηριότητας και συμπεριφοράς σε πραγματικές συνθήκες, παρουσιάζει όμως σημαντικές δυσκολίες. Το πρόβλημα συνήθως παρακάμπτεται με την καταγραφή και μελέτη εξαγόμενων μεγεθών όπως η τιμή κορυφής και το φορτίο, μία προσέγγιση που οδηγεί όμως σε αμφίβολα αποτελέσματα. Η παρούσα διατριβή επικεντρώνεται στην διερεύνηση και ταξινόμηση κυματομορφών ρεύματος διαρροής καταγεγραμμένων στο πεδίο. Αρχικά, παρατίθεται μια λεπτομερής ανασκόπηση της καταγραφής και ανάλυσης ρεύματος διαρροής σε εργαστηριακές και πραγματικές συνθήκες. Στην συνέχεια, περιγράφεται το πεδίο μετρήσεων, δύο Υποσταθμοί Υψηλής Τάσης 150kV, το αναπτυχθέν λογισμικό αλλά και ο Υπαίθριος Σταθμός Δοκιμών όπου πρόκειται να αξιοποιηθούν τα αποτελέσματα. Μελετώνται περισσότερες από 100.000 κυματομορφές, που έχουν καταγραφεί σε μια περίοδο που ξεπερνάει τα δέκα έτη. Εξετάζεται και αξιολογείται το πρόβλημα του θορύβου και ταυτοποιούνται τρεις διαφορετικοί τύποι θορύβου. Εξετάζεται η επίδρασή τους στο πρόβλημα συσσώρευσης δεδομένων αλλά και στην ποιότητα της εξαγόμενης πληροφορίας. Για την αντιμετώπιση του προβλήματος εφαρμόζονται και αξιολογούνται τρεις διαφορετικές τεχνικές. Για την περαιτέρω ταξινόμησή των κυματομορφών που απεικονίζουν δραστηριότητα, χρησιμοποιούνται διάφορες τεχνικές επεξεργασίας σήματος, εξαγωγής και επιλογής χαρακτηριστικών καθώς και αναγνώρισης προτύπων όπως η Wavelet Multi-Resolution Ανάλυση, η Ανάλυση Fourier, τα Νευρωνικά Δίκτυα, το t-test, ο αλγόριθμος mRMR, ο αλγόριθμος κ-πλησιέστερων γειτόνων, ο απλός Μπεϋζιανός ταξινομητής και οι Μηχανές Διανυσμάτων Υποστήριξης. Συγκεντρωτικά, δίνεται μια συνολική εικόνα των διαφορετικών ζητημάτων που σχετίζονται με την παρακολούθηση του ρεύματος διαρροής. Παρατίθεται μια πλήρης εικόνα των κυματομορφών όπως αυτές καταγράφονται σε πραγματικές συνθήκες, υπογραμμίζοντας ιδιαιτερότητες που σχετίζονται με την φύση της εφαρμογής. Εφαρμόζονται και αξιολογούνται νέες προσεγγίσεις για την ταξινόμηση των κυματομορφών. Τα συνολικά αποτελέσματα προσφέρουν σημαντική ενίσχυση στην αποτελεσματικότητα της τεχνικής της παρακολούθησης του ρεύματος διαρροής, συμβάλλοντας σημαντικά στην μελέτη της επιφανειακής δραστηριότητας και συμπεριφοράς των μονωτήρων υψηλής τάσης. / Leakage current monitoring is a widely applied technique for monitoring surface activity and condition of high voltage insulators. Field monitoring is necessary to acquire an exact image of activity and performance in the field. However, recording, managing and interpreting leakage current waveforms, the shape of which is correlated to surface activity, is a major task. The problem is commonly by-passed with the extraction, recording and investigation of values related to peak and charge, an approach reported to produce questionable results. The present thesis focuses on the investigation and classification of field leakage current waveforms. At first, a detailed background of measuring and analyzing leakage current both in lab and field conditions is provided. Then, the monitoring sites, two 150kV Substations, as well as the developed custom-made software and the newly constructed High Voltage Test Station where the results of this thesis are to be implemented, is briefly described. More than 100.000 waveforms are investigated, recorded through a period exceeding ten years. Field related noise is thoroughly described and evaluated. Three different types of noise are identified and their impact on the size of accumulated data and on data interpretation is investigated. Three different techniques to overcome the problem are applied and evaluated. Activity portraying waveforms are further investigated. Further classification of activity portraying waveforms is performed employing signal processing, feature extraction and selection algorithms as well as pattern recognition techniques such as Wavelet Multi-Resolution Analysis, Fourier Analysis, Neural Networks (NNs), student’s t-test, minimum Redundancy Maximum Relevance (mRMR), k-Nearest Neighbors (kNN), Naive Bayesian Classifier and Support Vector Machines (SVMs). Overall results provide a full image of the various aspects of field leakage current monitoring. A detailed image of field waveforms, revealing several new attributes, is documented. New approaches for the classification of leakage current waveforms are introduced, applied on field waveforms and evaluated. Results described in this thesis significantly enhance the effectiveness of the leakage current monitoring technique, providing a powerful tool for the investigation of surface activity and performance of high voltage insulators.
236

Ανάλυση συστήματος μεταφοράς με διασύνδεση Σ.Ρ. και PWM ρυθμιζόμενους μετατροπείς

Σακκάς, Σωτήρης 08 January 2013 (has links)
Τα τελευταία χρόνια έχει αρχίσει να διαδίδεται με γρήγορους ρυθμούς η μέθοδος μεταφοράς ισχύος μέσω συνεχούς ρεύματος. Προς αυτή την κατεύθυνση ώθηση έδωσε η ανάπτυξη νέων ημιαγωγικών διακοπτικών στοιχείων οδηγώντας σε περεταίρω ανάπτυξη και χρήση των συστημάτων μεταφοράς με συνεχές ρεύμα. Σε αυτή τη διπλωματική εργασία μελετάται ένα σύστημα μεταφοράς ισχύος με διασύνδεση συνεχούς ρεύματος (HVDC), που συνδέεται ανάμεσα σε δυο εναλλασσόμενα ηλεκτρικά δίκτυα με και χωρίς φορτίο. Την διασύνδεση συνεχούς ρέματος πραγματοποιούν δυο back-to-back AC/DC μετατροπείς VSC, που αναλαμβάνουν τους ρόλους του ανορθωτή και του αντίστροφα ισχύος. Οι μετατροπείς χρησιμοποιούν την διαμόρφωση πλάτους παλμού PWM. Αρχικά μελετάται θεωρητικά το μοντέλο των μετατροπέων και του back-to-back HVDC συστήματος και στην συνέχεια σχεδιάζεται και αναλύεται η λειτουργία του ανάμεσα σε δυο δίκτυα εναλλασσομένου ρεύματος με ή χωρίς την ταυτόχρονη παρουσία φορτίου. Τέλος προσομοιώνεται το σύστημα μέσω του λογισμικού Matlab και συγκεκριμένα της εφαρμογής Simulink για την εξαγωγή συμπερασμάτων. / In the past few years the method of power transmission by means of direct current has expanded rapidly. To this direction a push forward has been given by the development of new semi-conductive switching valves leading to a further development of transmission systems by direct current. In this thesis what is considered is a power transmission system via direct current HVDC connected between two AC electric networks with or without load. The direct current connection is achieved through back-to-back AC/DC converters VSC which undertake the role of rectifier and that of inverter of power. The converters use the Pulse Width Modulation (PWM). At first the converter model and the back-to-back HVDC system is theoretically approached and in the process what is designed and analyzed is its function between two networks of AC current with or without the simultaneous presence of load. Finally the system is simulated through software Matlab and specifically the application of simulink in order to draw conclusions.
237

Propriétés physiques et électriques de polymères électroactifs / Physical and electrical properties of electroactive polymers

Hammami, Saber 23 May 2017 (has links)
Les élastomères diélectriques sont de plus en plus utilisés pour la réalisation des transducteurs dans de nombreux domaines industriels : interface haptique, robotique, biomimétisme, conversion d’énergie. Pour le fonctionnement de toutes ces applications, le polymère électroactif est soumis à une haute tension (de 1 à 10kV). Toutefois, le courant de fuite diminue l’efficacité et la durée de vie des dispositifs utilisant ces matériaux.Par ailleurs, une précontrainte mécanique (étirement) est généralement appliquée au polymère pour accroître l’efficacité énergétique dans la conversion mécanique-électrique. Les courants de fuite (et donc le champ de claquage du polymère) seront ainsi conditionnés par cette précontrainte et ce point doit faire l’objet d’une étude détaillée.L’objet de ce travail de thèse est de mener des analyses de courant de fuite sur des polymères électroactifs (élastomères polyacrylates du commerce VHB4910 et silicones Sylgard 186) non contraints et contraints mécaniquement pour évaluer l’amélioration ou la dégradation des performances électriques lorsqu’ils seront plus tard intégrés en géométrie électrode-polymère-électrode dans des transducteurs.Tout d’abord, nous avons mené une étude exhaustive sur l’influence des facteurs externes (étirement, température, champ électrique, nature de l’électrode) sur les propriétés électriques du polyacrylate VHB4910. Les études ont été réalisés sur des durées de polarisation courtes (quelques minutes) et longues (jusqu’à 15 heures). Au cours de ce travail, nous sommes également intéressés à l’étude du phénomène d’autocicatrisation sur le sylgard 186. Les tests ont été conduits pour différents types d’électrodes (or, aluminium, graphène, nanoplaquettes de graphène : GnP) déposées sur la surface de silicone. Une analyse par microscopie optique de la zone évaporée a été menée.La finalité de ces travaux aura permis d’optimiser des structures de récupération d’énergie électrostatique à base de polymères électroactifs. / Electroactive polymers known as dielectric elastomers have shown considerable promise for transducers. They are attractive for a wide range of innovative applications including softs robots, adaptive optics, haptic interface or biomedical actuation thanks to their high energy density and good efficiency. For the functioning of all these application, the electroactive polymer is subjected to high electrical field. Nevertheless, the performances of these transducers are affected by the losses and especially the ones induced by the leakage current.Mechanical pre-stretch is an effective method to improve actuation when a voltage is applied to the device made up of a dielectric elastomer sandwiched between two compliant electrodes. The overall performances of the structure (electromechanical conversion, efficiency, strain induced…) depend strongly on the electric and mechanical properties of the elastomer. Regarding electric characteristics, dielectric permittivity, dissipation factor and electric breakdown field have been deeply investigated according to various parameters such as frequency, temperature, pre-stretch, or nature of the electrodes but complete analysis of the leakage current is missing in the scientific literature.Thus, this work reports an extensive investigation on the stability of the current-time characteristics in dielectric elastomer. Particularly, we focus on the influence of the nature of the electrodes and pre-stress applied to the transducer. In order to evaluate the influence of the time duration on the behavior of the leakage current, short and long-term electrical stress times was applied during short times and up to 15 hours.Leakage current in electroactive polymers were discussed for a commercial polyacrylate (VHB4910 from 3M) currently used for soft transducers applications. This current is investigated as a function of external factors (stretching, temperature, type of material for electrodes)In order to evaluate the limitations in term of voltage and in the goal to increase the lifetime of these transducers, the second part of our study is focused on the dielectric strength of silicone rubbers for various types of electrodes (gold, Aluminum, graphene nanoplatelets, graphene : GnP). The effect of self-healing is particularly studied and a selection of electrodes for soft transducers based on dielectric elastomers is proposed.
238

Caractérisation et mise en œuvre de composants SiC Haute Tension pour l'application transformateur moyenne fréquence en traction ferroviaire / Characterization and implementation of High Voltage SiC devices for medium frequency transformer application in railway traction

Casarin, Jérémy 30 November 2012 (has links)
L'objectif du projet CONCIGI-HT (CONvertisseur alternatif-continu Compact à Isolement Galvanique Intégré Haute Tension) est d'augmenter le rendement des chaînes de traction tout en réduisant la masse et le volume de la fonction de conversion Alternatif/Continu. Pour cela, l'ensemble transformateur basse fréquence - redresseur est remplacé par une structure multi-convertisseurs, directement connectée à la caténaire haute tension et intégrant des transformateurs fonctionnant en moyenne fréquence (plusieurs kHz). Cette thèse concerne plus particulièrement la caractérisation et la mise en œuvre de composants semi-conducteurs haute tension dans des structures de conversion statiques à étage intermédiaire moyenne fréquence. L'étude est effectuée sur la base d'une chaîne de traction de 2 MW fonctionnant sur un réseau 25 kV/50 Hz. Le premier chapitre présente l'état de l'art de l'Automotrice à Grande Vitesse (AGV) récemment produite par ALSTOM. C'est la chaîne de traction de cet engin qui sert de référence pour l'étude des nouvelles topologies à transformateur moyenne fréquence. Le deuxième chapitre décrit tout d'abord la structure d'une chaîne de traction classique et présente ensuite deux topologies multicellulaires à transformateur moyenne fréquence applicables en traction électrique ferroviaire (la structure indirecte à redresseur de courant MLI et convertisseur DC/DC à résonance ainsi que la topologie directe associant des convertisseurs duaux). Les avantages et inconvénients de ces topologies sont mis en évidence. Le troisième chapitre concerne la mise en œuvre et la caractérisation en commutation douce de composants Silicium 6,5 kV dans les deux topologies présentées précédemment. Deux bancs de test, représentant un étage élémentaire de conversion, ainsi que des allumeurs spécifiques dédiés à la commutation douce, ont été réalisés. Ils permettent l'étude des semi-conducteurs en régime permanent dans des conditions nominales de fonctionnement (3,6 kV / 100 A). Le quatrième chapitre présente la mise en œuvre et la caractérisation de composants en carbure de silicium (SiC). Pour cela des modules de puissance à base de puces 10 kV (MOSFET et Diodes) ont été réalisés. Les résultats expérimentaux, obtenus sur les bancs de test réalisés au chapitre précédent, mettent en évidence une réduction significative des pertes et démontrent la viabilité de la topologie à convertisseurs duaux pour une application en 25 kV/50 Hz. La conclusion présente un premier design d'un bloc élémentaire et les gains en masse et volume ainsi que les économies d'énergies qui pourront être obtenus par rapport à une structure classique. / The objective of the CONCIGI-HT project (Compact AC/DC converter with Integrated High Voltage Galvanic Insulation) is to increase the efficiency of traction drives while reducing the mass and volume of the AC/DC conversion. To do that, the part low-frequency transformer - rectifier is replaced by a multi-converter topology, directly connected to the high voltage power supply and incorporating medium frequency transformers (several kHz). This thesis relates more particularly to the characterization and implementation of high voltage semiconductors in conversion topologies with intermediate medium frequency link. The study is performed on the basis of a traction drive of 2 MW operating on a 25 kV/50 Hz power supply. The first chapter presents the state of the art of the Automotrice à Grande Vitesse (AGV) recently produced by ALSTOM. The traction drive of this vehicle is used as a reference for the study of new topologies with medium frequency transformer. The second chapter first describes the structure of a conventional traction drive and then presents two multicellular topologies with medium frequency transformer applicable to railway traction (the indirect structure with PWM rectifier and DC/DC resonant converter and the direct topology combining dual converters). The advantages and disadvantages of these topologies are highlighted. The third chapter deals with the implementation and soft switching characterization of 6.5 kV Silicon components in both topologies presented above. Two test benches, representing a basic conversion stage, as well as specific drivers dedicated to the soft switching, has been made. They allow the study of semiconductors in nominal operating conditions (3.6 kV / 100 A). The fourth chapter presents the implementation and characterization of silicon carbide components (SiC). For this, power modules based on 10 kV chips (MOSFET and Diodes) have been achieved. The experimental results obtained on test benches made in the previous chapter, show a significant reduction in losses and demonstrate the viability of the dual converter topology for a 25 kV/50 Hz application. The conclusion presents the first design of an elementary block and gains in mass and volume as well as the energy savings that can be achieved compared to a conventional structure.
239

Active Power Flow Tracing for Preventive Control in Deregulated Power Systems

Adhip, * January 2017 (has links) (PDF)
Modern day power systems present an open access environment, inspiring participation from small scale and large power suppliers. With multiple players in the system driven by the market, proper monitoring and control of system becomes a major concern. This transformation is accompanied by dynamic consumption patterns and rising power demands. The expanding network encompassing EHV/AC network, HVDC and FACTS devices, along with increased penetration of renewable sources, viz. solar and wind energy at medium and low voltage levels, adds to the problem. Independent System Operators (ISO) are entrusted with ensuring smooth operation, and employing proper preventive measures to eliminate a possible cascade tripping leading to a partial or large-scale blackout. To aid the operator in the process of ensuring secure operation of the grid, there are many tools that provide required information and guidance. Power flow tracing is one such tool that aids the operator in congestion management, transmission pricing, transaction evaluation, loss allocation and reactive power optimization. In this thesis, a novel active power flow tracing approach is proposed that takes into account, the real-time operating conditions and network topology. It provides the decomposition of active power flow in a line into respective components injected by various generators in the system. It also provides the contribution of the generators to various loads in the system. The approach is simple and computationally fast, making it an ideal tool to aid preventive control decisions. Based on the proposed active power flow tracing, a congestion management approach is developed. The approach indicates the least number of generators that need to be coordinated for generation rescheduling, so as to alleviate overloading in affected transmission lines and transformers. The approach also takes into consideration the operating constraints on the system, while computing the optimal rescheduling amongst selected generators using LP technique. The thesis also presents a real power loss allocation approach based on the proposed power flow tracing. Loss allocation is an important part of tariff design as the cost associated with losses amounts to a sizable fraction of total revenue collected from the loads. The approach provides information as to how losses are distributed among loads and how much each generator is providing for the loss share of each load. The approaches developed in the thesis are illustrated on a sample 10-bus equivalent system, IEEE 30-bus, and IEEE 39-bus systems. Results for typical case studies are presented for practical systems of 72-bus equivalent and 203-bus equivalent of Indian Southern grid.
240

Evaluation of Room Temperature Vulcanized (RTV) Silicone Rubber Coated Porcelain Post Insulators under Contaminated Conditions

January 2013 (has links)
abstract: This thesis concerns the flashover issue of the substation insulators operating in a polluted environment. The outdoor insulation equipment used in the power delivery infrastructure encounter different types of pollutants due to varied environmental conditions. Various methods have been developed by manufacturers and researchers to mitigate the flashover problem. The application of Room Temperature Vulcanized (RTV) silicone rubber is one such favorable method as it can be applied over the already installed units. Field experience has already showed that the RTV silicone rubber coated insulators have a lower flashover probability than the uncoated insulators. The scope of this research is to quantify the improvement in the flashover performance. Artificial contamination tests were carried on station post insulators for assessing their performance. A factorial experiment design was used to model the flashover performance. The formulation included the severity of contamination and leakage distance of the insulator samples. Regression analysis was used to develop a mathematical model from the data obtained from the experiments. The main conclusion drawn from the study is that the RTV coated insulators withstood much higher levels of contamination even when the coating had lost its hydrophobicity. This improvement in flashover performance was found to be in the range of 20-40%. A much better flashover performance was observed when the coating recovered its hydrophobicity. It was also seen that the adhesion of coating was excellent even after many tests which involved substantial discharge activity. / Dissertation/Thesis / M.S. Electrical Engineering 2013

Page generated in 0.0811 seconds