• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 9
  • 7
  • 5
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 31
  • 13
  • 10
  • 10
  • 9
  • 9
  • 9
  • 9
  • 8
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Caractérisation de caillots sanguins par méthodes ultrasonores

Bosio, Guillaume 12 1900 (has links)
Les caillots sanguins sont responsables de nombreuses pathologies, telles que les thromboses veineuses profondes (TVP), les embolies pulmonaires (EP) ou les accidents vasculaires cérébraux (AVC). La thromboembolie veineuse, regroupant les thromboses veineuses profondes et les embolies pulmonaires, ainsi que les accidents vasculaires cérébraux sont parmi les principales causes de décès. La formation d’un caillot sanguin survient suite à une lésion de la paroi endothéliale, d’un changement hémodynamique de l’écoulement sanguin ou de conditions d’hypercoagulation du sang. Lors de situations pathologiques, le caillot ne se dissout pas naturellement et des anticoagulants sont prescrits. Leur but est d’empêcher l’évolution du caillot et de prévenir des risques de récidives. Dans le cas d’un accident vasculaire cérébral ou de certaines embolies pulmonaires, de l'activateur tissulaire du plasminogène recombinant (rt-PA) peut être prescrit pour dissoudre directement le caillot. Ces traitements comportent des risques d’hémorragie interne, et une incertitude persiste encore sur leur durée d’administration. La caractérisation des caillots sanguins vise à mieux comprendre leur développement pour pouvoir adapter les traitements et potentiellement à confirmer leur effet. Un moyen de caractériser les tissus est d’utiliser des méthodes ultrasonores. L’élastographie, une de ces méthodes, permet de calculer la rigidité d’un tissu, caractérisé par son module d’Young. On appelle élastographie dynamique les méthodes d’élastographie basées sur la propagation d’ondes de cisaillement dans le tissu pour calculer son module d’Young (relié à la vitesse de l’onde). Plusieurs études ont montré que le module d’Young de caillots sanguins augmentait avec le temps et que des caillots plus vieux et plus denses étaient plus résistants à la dissolution. La dispersion de l’onde de cisaillement reliée à la contribution visqueuse du tissu est un paramètre nouvellement disponible sur certains échographes cliniques qui est peu étudié dans le cadre des caillots sanguins. L’atténuation de l’onde de cisaillement est également un paramètre acoustique, non explorée dans le cas des caillots sanguins. L’utilisation de l’atténuation de l’onde de cisaillement a montré des résultats encourageant en simulations et sur fantômes. Cependant, avec les méthodes actuelles, le calcul de l’atténuation d’onde de cisaillement suppose un milieu homogène ne favorisant pas la présence de résonances acoustiques, ce qui n’est pas le cas pour des caillots cylindriques dans des vaisseaux sanguins. L’enveloppe ultrasonore peut également être étudiée de manière statistique et les paramètres issus de ces statistiques reflètent la microstructure des tissus imagés. L’objectif général de cette thèse est de caractériser les caillots sanguins pendant leur évolution à l’aide des différents paramètres découlant des ultrasons. Cette caractérisation vise à permettre aux soignants d’adapter l’administration du traitement. Un autre objectif consiste à évaluer l’effet du traitement sur les différents paramètres ultrasonores afin d’attester son efficacité. Pour réaliser ces objectifs l’étude se sépare en trois parties. La première partie est une étude in vivo en partenariat avec le centre hospitalier universitaire de Grenoble qui vise à étudier le module d’Young et les paramètres d’ultrasons statistiques au cours du temps chez des patients présentant des thromboses veineuses profondes. Les patients étaient sous anticoagulants ; le module d’Young n’a pas montré de changement significatif entre les mesures aux jours 0, 7 et 30. Les paramètres statistiques (étudiés suivant la distribution statistique homodyne K) ont montré une augmentation de l’intensité des rétrodiffuseurs (probablement liée à une augmentation du nombre de brins de fibrine et/ou du nombre de globules rouges) et une désorganisation des rétrodiffuseurs. Une des conclusions est que les paramètres statistiques pourraient permettre d’améliorer la caractérisation de caillots sanguins même quand le module d’Young ne varie pas significativement. La deuxième partie se concentre sur l’analyse du phénomène de résonance acoustique présent lors du passage d’ondes de cisaillement dans le caillot. Le but était de trouver une région d’intérêt où le calcul de l’atténuation de l’onde de cisaillement présente le moins de variation associée à ce phénomène. Les paramètres liés à la résonance, le module d’Young, la dispersion et l’atténuation de l’onde de cisaillement ont pu être reportés dans des fantômes de différents diamètres ainsi que dans des caillots in vitro pendant leur coagulation. Une région d’intérêt minimisant la résonance lors du calcul de l’atténuation de l’onde de cisaillement a pu être trouvée. La troisième étude porte sur l’effet de traitement avec du rt-PA sur le module d’Young, la dispersion de l’onde de cisaillement, l’atténuation de l’onde de cisaillement et les paramètres d’ultrasons statistiques. Du sang de porc a été collecté et 3 caillots par échantillon ont été préparés, chacun subissant une condition différente de traitement (pas de traitement, traitement à 20 minutes après le début de la coagulation et traitement à 60 minutes après cette phase initiale). Les résultats montrent que le module d’Young diminue significativement avec l’ajout du traitement, la dispersion de l’onde de cisaillement augmente pour les caillots traités à 60 minutes comparés à ceux non traités, l’atténuation de l’onde de cisaillement augmente pour les caillots traités à 20 minutes comparés à ceux non traités et l’intensité des rétrodiffuseurs diminue significativement dans les deux conditions de traitement. Ces paramètres pourraient aider à confirmer l’effet du traitement et déceler si des patients y sont résistants ou non. Cette thèse a permis une meilleure compréhension des propriétés mécaniques et acoustiques des caillots sanguins au cours de la coagulation et en fonction de traitements. Tout ceci constitue autant de propriétés qui pourraient être utilisées afin d’adapter la dose et la durée d’un traitement afin de réduire les effets secondaires lors de la prise en charge des patients. / Blood clots are the cause of numerous pathologies, including deep vein thrombosis (DVT), pulmonary embolism (PE) and stroke. Venous thromboembolism, which includes deep vein thrombosis and pulmonary embolism, and stroke are among the leading causes of death. Blood clots form as a result of damage to the endothelial lining, hemodynamic changes in blood flow or hypercoagulable blood conditions. In pathological situations, the clot does not dissolve naturally, and anticoagulants are prescribed. Their purpose is to prevent the clot from progressing and to reduce the risk of recurrence. In the case of stroke or certain pulmonary embolisms, recombinant tissue plasminogen activator (rt-PA) may be prescribed to dissolve the clot. While these treatments can be effective, they do pose a risk of causing internal bleeding, and there is currently uncertainty regarding the optimal duration for administering them. Blood clot characterization aims to better understand how blood clots develop, so as to be able to adapt treatments and potentially confirm their effect. One way of characterizing tissues is to use ultrasound methods. Elastography, one such method, calculates the stiffness of a tissue characterized by its Young's modulus. Elastography methods based on shear wave propagation in a tissue to calculate the Young's modulus (related to the wave velocity) are known as dynamic elastography approaches. Several studies have shown that the Young's modulus of blood clots increases with time, and that older and denser clots are more resistant to dissolution. Shear wave dispersion related to the viscous contribution of a tissue is a newly available parameter on some clinical ultrasound scanners. However, little is known in the context of blood clots. Shear wave attenuation is also an acoustic parameter related to tissue viscosity and it is unexplored in the case of blood clots. The use of shear wave attenuation has shown encouraging results in simulations and on phantoms. However, with current methods, the calculation of the shear wave attenuation assumes a resonance-free homogeneous medium, which is not the case for cylindrical clots in blood vessels. The ultrasound envelope can also be studied statistically, and the parameters derived from these statistics reflect the microstructure of the tissues imaged. The general aim of this thesis is to characterize blood clots as they evolve, using various parameters derived from ultrasound. This characterization is intended to enable caregivers to adapt treatment administration. Another objective is to evaluate the effect of treatment on the various ultrasound parameters, in order to attest its effectiveness. To achieve these objectives, the study is divided into three parts. The first part is an in vivo study in partnership with Grenoble University Hospital to investigate the Young's modulus and statistical ultrasound parameters over time in patients with deep vein thrombosis. The patients were on anticoagulants, and the Young's modulus showed no significant changes between measurements on days 0, 7 and 30. Statistical parameters (studied according to the homodyne K statistical distribution) showed an increase in the intensity of scatterers (probably linked to an increase in the number of fibrin strands and/or number of red blood cells) and a disorganization of scatterers. One conclusion is that statistical parameters might be used to improve the characterization of blood clots even when the Young's modulus does not vary significantly. The second part focuses on the analysis of the resonance phenomenon present when shear waves pass through the clot. The aim was to find a region of interest where the calculation of the shear wave attenuation shows the least possible variation due to this behavior. Parameters related to resonance, the Young's modulus, shear wave dispersion and shear wave attenuation were plotted in phantoms of different diameters and in in vitro blood clots during coagulation. A region of interest was found, which minimized resonances when calculating shear wave attenuation. The third study investigates the effect of in vitro treatments with rt-PA on the Young's modulus, shear wave dispersion, shear wave attenuation and statistical ultrasound parameters. Porcine blood was collected and 3 clots per sample were prepared, each undergoing a different treatment condition (no treatment, treatment at 20 minutes after the beginning of coagulation and treatment at 60 minutes after the onset of coagulation). The Young's modulus decreased significantly with treatment, the shear wave dispersion increased for clots treated at 60 minutes compared to those untreated, the shear wave attenuation increased for clots treated at 20 minutes compared to those untreated, and the backscatter intensity decreased significantly in both treatment conditions. These parameters might help confirm the effect of a treatment and detect whether or not patients are resistant to it. This thesis has led to a better understanding of the mechanical and acoustic properties of blood clots during coagulation and as a function of a treatment. These properties can be used to adapt the dose and duration of treatment to reduce side effects in the management of patients.
12

Ultra-compact integrated silicon photonics balanced coherent photodetector

Meyer, Jason T., Fallahi, Mahmoud 13 February 2016 (has links)
In this paper, the performance simulations of a novel ultra-compact balanced coherent photodetector for operation at a wavelength of 1.5 mu m are presented and design proposals for future fabrication processes are provided. It consists of a compact 2x2 MMI that is evanescently coupled into a germanium MSM photodetection layer. The simulations demonstrate dark current less than 10 nA, capacitance less than 20 fF, and optical bandwidth in the 10-30 GHz range. We propose utilizing the simplicity of direct wafer bonding to bond the detection layer to the output waveguides to avoid complicated epitaxial growth issues. This ultra-compact device shows promise as a high-speed, low-cost integrated silicon photonics solution for the telecommunications infrastructure.
13

Adaptive Phase Measurements

Berry, Dominic William Unknown Date (has links)
In this thesis I consider the general problem of how to make the best possible phase measurements using feedback. Both the optimum input state and optimum feedback are considered for both single-mode dyne measurements and two-mode interferometric measurements. I derive the optimum input states under general dyne measurements when the mean photon number is fixed, both for general states and squeezed states. I propose a new feedback scheme that introduces far less phase uncertainty than mark II feedback, and is very close to the theoretical limit. I also derive results for the phase variance when there is a time delay in the feedback loop, showing that there is a lower limit to the introduced phase variance, and this is approached quite accurately under some conditions. I derive the optimum input states for interferometry, showing that the phase uncertainty scales as 1/N for all the common measures of uncertainty. This is contrasted with the |j0> state, which does not scale as 1/N for all measures of phase uncertainty. I introduce an adaptive feedback scheme that is very close to optimum, and can give scaling very close to 1/N for the uncertainty. Lastly I consider the case of continuous measurements, for both the dyne and interferometric cases.
14

Hybrid quantum information processing with continuous and discrete variables of light fields

Donati, Gaia January 2015 (has links)
Quantum correlations play a fundamental role in quantum information science. The variety of their manifestations has become increasingly apparent following the development of novel light sources, protocols and photodetectors. One broad classification identifies two instances of non-classical correlations: particle and mode entanglement. These categories mirror two coexisting descriptions of quantum systems in terms of discrete and continuous variables of the electromagnetic field. The past decades have generated a number of promising results based on schemes which encompass elements from both frameworks, rather than viewing the two descriptions as mutually exclusive. In this context, it is possible to conceive and realise experiments where either the quantum resource or the detection system is 'hybrid'. Optical weak-field homodyne detectors bring together phase sensitivity and photon counting; as such, they represent a detection scheme which works across continuous and discrete variables of the radiation field. In this thesis we present a two-mode weak-field homodyne detection layout with added photon-number resolution and apply it to the study of a split single-photon state and a squeezed vacuum state. As a first test of the capabilities of this system, we investigate the reconstruction of relevant features of a given quantum resource - such as its photon statistics - with our detection scheme. Further, we experimentally demonstrate the observation of an instance of non-classical optical coherence which combines the continuous- and discrete-variable descriptions explicitly. The ability to probe phenomena at the interface of wave and particle regimes opens the way to novel, improved schemes for quantum information processing. From a more fundamental perspective, such hybrid approaches may shed light on the very roots of quantum enhancement.
15

Quantitative ultrasound imaging during shear wave propagation for application related to breast cancer diagnosis

Alavi Dorcheh, Marzieh 04 1900 (has links)
Dans le contexte de la caractérisation des tissus mammaires, on peut se demander ce que l’examen d’un attribut en échographie quantitative (« quantitative ultrasound » - QUS) d’un milieu diffusant (tel un tissu biologique mou) pendant la propagation d’une onde de cisaillement ajoute à son pouvoir discriminant. Ce travail présente une étude du comportement variable temporel de trois paramètres statistiques (l’intensité moyenne, le paramètre de structure et le paramètre de regroupement des diffuseurs) d’un modèle général pour l’enveloppe écho de l’onde ultrasonore rétrodiffusée (c.-à-d., la K-distribution homodyne) sous la propagation des ondes de cisaillement. Des ondes de cisaillement transitoires ont été générés en utilisant la mèthode d’ imagerie de cisaillement supersonique ( «supersonic shear imaging » - SSI) dans trois fantômes in-vitro macroscopiquement homogènes imitant le sein avec des propriétés mécaniques différentes, et deux fantômes ex-vivo hétérogénes avec tumeurs de souris incluses dans un milieu environnant d’agargélatine. Une comparaison de l’étendue des trois paramètres de la K-distribution homodyne avec et sans propagation d’ondes de cisaillement a montré que les paramètres étaient significativement (p < 0,001) affectès par la propagation d’ondes de cisaillement dans les expériences in-vitro et ex-vivo. Les résultats ont également démontré que la plage dynamique des paramétres statistiques au cours de la propagation des ondes de cisaillement peut aider à discriminer (avec p < 0,001) les trois fantômes homogènes in-vitro les uns des autres, ainsi que les tumeurs de souris de leur milieu environnant dans les fantômes hétérogénes ex-vivo. De plus, un modéle de régression linéaire a été appliqué pour corréler la plage de l’intensité moyenne sous la propagation des ondes de cisaillement avec l’amplitude maximale de déplacement du « speckle » ultrasonore. La régression linéaire obtenue a été significative : fantômes in vitro : R2 = 0.98, p < 0,001 ; tumeurs ex-vivo : R2 = 0,56, p = 0,013 ; milieu environnant ex-vivo : R2 = 0,59, p = 0,009. En revanche, la régression linéaire n’a pas été aussi significative entre l’intensité moyenne sans propagation d’ondes de cisaillement et les propriétés mécaniques du milieu : fantômes in vitro : R2 = 0,07, p = 0,328, tumeurs ex-vivo : R2 = 0,55, p = 0,022 ; milieu environnant ex-vivo : R2 = 0,45, p = 0,047. Cette nouvelle approche peut fournir des informations supplémentaires à l’échographie quantitative statistique traditionnellement réalisée dans un cadre statique (c.-à-d., sans propagation d’ondes de cisaillement), par exemple, dans le contexte de l’imagerie ultrasonore en vue de la classification du cancer du sein. / In the context of breast tissue characterization, one may wonder what the consideration of a quantitative ultrasound (QUS) feature of a scattering medium (such as a soft biological tissue) under propagation of a shear wave adds to its discriminant power. This work presents a study of the time varying behavior of three statistical parameters (the mean intensity, the structure parameter and the clustering parameter of scatterers) of a general model for the ultrasound backscattering echo envelope (i.e., the homodyned K-distribution) under shear wave propagation. Transient shear waves were generated using the supersonic shear imaging (SSI) method in three in-vitro macroscopically homogenous breast mimicking phantoms with different mechanical properties, and two ex-vivo heterogeneous phantoms with mice tumors included in an agar gelatin surrounding medium. A comparison of the range of the three homodyned K-distribution parameters with and without shear wave propagation showed that the parameters were significantly (p < 0.001) affected by shear wave propagation in the in-vitro and ex-vivo experiments. The results also demonstrated that the dynamic range of the statistical parameters during shear wave propagation may help discriminate (with p < 0.001) the three in-vitro homogenous phantoms from each other, and also the mice tumors from their surrounding medium in the ex-vivo heterogeneous phantoms. Furthermore, a linear regression model was applied to relate the range of the mean intensity under shear wave propagation with the maximum displacement amplitude of speckle. The linear regression was found to be significant : in-vitro phantoms : R2 = 0.98, p < 0.001 ; ex-vivo tumors : R2 = 0.56, p = 0.013 ; ex-vivo surrounding medium : R2 = 0.59, p = 0.009. In contrast, the linear regression was not as significant between the mean intensity without shear wave propagation and mechanical properties of the medium : in-vitro phantoms : R2 = 0.07, p = 0.328, ex-vivo tumors : R2 =0.55, p = 0.022 ; ex-vivo surrounding medium : R2 = 0.45, p = 0.047. This novel approach may provide additional information to statistical QUS traditionally performed in a static framework (i.e., without shear wave propagation), for instance, in the context of ultrasound imaging for breast cancer classification.
16

Détection non destructive d'un atome unique par interaction dispersive avec un champ mésoscopique dans une cavité

Maioli, Paolo 09 July 2004 (has links) (PDF)
La détection des états d'un qubit est un élément essentiel dans la réalisation d'expériences d'information quantique. Dans le système étudié, le bit quantique est codé dans les états d'énergie interne d'un atome de Rydberg circulaire à deux niveaux. Dans ce mémoire nous présentons une nouvelle technique de détection des atomes de Rydberg circulaires basée sur l'interaction dispersive d'un atome avec un champ micro-onde mésoscopique à l'intérieur d'une cavité supraconductrice de très grand facteur de qualité. L'indice de réfraction de l'atome, dépendant de son niveau d'énergie interne, déphase le champ micro-onde, et une procédure de détection homodyne transforme l'information codée dans la phase du champ en une information d'intensité. L'intensité finale du champ est lue par un échantillon mésoscopique d'atomes. Il s'agit d'une technique de détection non destructive, puisque le processus de détection n'ionise pas l'atome, mais le projette simplement dans l'état mesuré. De plus, le processus de détection intrique l'état interne d'un atome au niveau d'excitation d'un ensemble de plusieurs atomes, permettant de créer des superpositions cohérentes d'états atomiques mésoscopiques et ouvrant de nouvelles perspectives pour des tests de décohérence Nous présentons le principe de la technique et de nombreux résultats expérimentaux, ainsi que de possibles schémas d'application.
17

Communication et cryptographie quantiques avec des variables continues

Grosshans, Frédéric 31 December 2002 (has links) (PDF)
Ces dernières années, les variables continues ont émergées en tant qu alternative aux variables discrètes dans les communications quantiques. Cette thèse s'inscrit dans ce cadre des communications quantiques avec des variables continues. Les variables continues utilisées ici sont les quadratures d'un mode du champ électromagnétique. Pour les mesurer, nous avons construit une détection homodyne équilibrée, limitée au bruit de photons, impulsionnelle et résolue en temps. Celle-ci peut effectuer 800 000 mesures par seconde. En se fondant sur la limite de la duplication quantique, nous montrons qu'une valeur de la fidélité supérieure à 2/3 dans un protocole de téléportation quantique garantit que l'état téléporté est la meilleure copie qui reste de l'état d'entrée. Nous introduisons de nouveaux protocoles de distribution quantique de clef utilisant des variables quantiques continues, sûrs face à des attaques individuelles pour toute valeur de la transmission de la ligne optique entre Alice et Bob. En particulier, il n'est pas nécessaire que cette transmission soit plus grande que 50 % (moins de 3 dB de pertes). Ni compression des fluctuations quantiques, ni intrication ne sont nécessaires. Nous avons implémenté expérimentalement ces protocoles, en utilisant la détection homodyne limitée au bruit de photon mentionnée plus haut et des états cohérents. L'extraction complète de la clef secrète est réalisée en utilisant une technique de réconciliation par tranches inversée suivie d amplification de confidentialité. Notre dispositif expérimental produit un taux net de transmission de clef de 1,7 megabits par seconde pour une ligne sans pertes, et 75 kilobits par seconde pour une ligne avec 3,1 dB de pertes. Les limitations actuelles sont essentiellement techniques et proviennent surtout de l'efficacité limitée du logiciel de réconciliation.
18

Dispositifs pour la cryptographie quantique

Tualle-Brouri, Rosa 21 September 2006 (has links) (PDF)
Ce mémoire couvre l'ensemble de mes activités de recherche au laboratoire Charles Fabry, dans le groupe d'optique quantique dirigé par Philippe Grangier. Ces activités entrent dans le cadre de l'information quantique, discipline au carrefour de la théorie de l'information et de la mécanique quantique. Nous nous sommes ainsi attachés à synthétiser et à étudier différents états quantiques de la lumière, avec pour objectif la mise au point de protocoles de cryptographie quantique.
19

Manipulation de champs quantiques mésoscopiques

Ferreyrol, Franck 22 March 2011 (has links) (PDF)
L'objectif de cette thèse concerne la manipulation à l'échelle quantique du champ électromagnétique dans le cadre de l'information quantique à variables continues. Pour ce faire nous mélangeons les outils de l'optique quantique à variables discrètes, où la lumière est décrite en termes de photons, avec l'approche continue, traitant des quadratures du champ. Cette technique permet de produire des états non-classiques décrits par des fonctions de Wigner prenant des valeurs négatives. Nous avons pu générer des états intriqués à partir d'impulsions lumineuses initialement indépendantes et pouvant être séparées par une longue distance, l'intrication s'effectuant au travers d'un canal acceptant de fortes pertes. Nous avons ensuite démontré et caractérisé expérimentalement un protocole non-déterministe permettant d'amplifier de faibles signaux sans en amplifier le bruit quantique, augmentant ainsi le rapport signal sur bruit. Puis nous avons mis en œuvre et comparé expérimentalement différentes mesures de non-gaussianité d'un état quantique : ce caractère propre à une description continue de la lumière est d'un intérêt capital pour l'information quantique. Enfin nous avons développé et testé deux améliorations pour notre dispositif. La première est un amplificateur femtoseconde pour notre laser impulsionnel, qui permettra d'obtenir de meilleurs états de départ pour nos expériences. La deuxième est un appareil capable de discriminer le nombre de photon, donnant ainsi des résultats plus précis que ceux des détecteurs dont nous disposons actuellement qui sont uniquement capable de détecter la présence de photons.
20

Mémoires holographiques microstructurées à réseaux de Lippmann

Maire, Guillaume 09 December 2005 (has links) (PDF)
Le stockage holographique de données est actuellement une voie très prometteuse pour accroître de manière conséquente les capacités et débits des mémoires optiques amovibles. L'architecture de mémoire holographique visée à long terme par ces travaux consiste en une couche de données structurée en une matrice de microfibres perpendiculaires au disque. Les hologrammes sont des réseaux de Bragg multiplexés en longueur d'onde dans chaque microfibre. Le matériau d'enregistrement envisagé est un photopolymère dopé par des centres moléculaires bistables, le photopolymère servant à la structuration en microfibres et les centres à l'enregistrement des réseaux. L'impact de la répartition discrète de ces centres et de la non linéarité de leur réponse optique sur le rapport signal sur bruit de lecture a tout d'abord été évalué par de premières modélisations. Par ailleurs, une procédure d'écriture-lecture en configuration de type Lippmann a été définie afin de simplifier l'architecture de la mémoire et accroître le signal de lecture grâce à une détection homodyne des hologrammes. La mise en œuvre pratique de cette procédure a alors par la suite été étudiée au travers de deux dispositifs expérimentaux d'écriture-lecture. Le premier montage a ainsi abouti à une démonstration de la procédure dans une configuration simplifiée, limitant les difficultés relatives au matériau et à la géométrie d'enregistrement, en bon accord avec notre modèle théorique. L'acquis obtenu avec cette première démonstration a ensuite été utilisé pour mettre en place un second dispositif, afin de valider notre procédure dans une configuration plus réaliste impliquant un photopolymère comme milieu de stockage.

Page generated in 0.0494 seconds