1

Degradação de poluentes emergentes por processos oxidativos avançados (O3, O3/UV, O3/Fe2+, O3/UV/Fe2+) visando o tratamento de efluentes hospitalares / Degradation of emergent pollutants by advanced oxidative processes (O3, O3/UV, O3/Fe2+, O3/UV/Fe2+) aiming at hospital wastewater treatment

Souza, Fernanda Siqueira January 2016 (has links)
Compostos farmacêuticos são detectados em diversas matrizes ambientais. Estes compostos, quando não eliminados por técnicas avançadas de tratamento, contribuem para impactos ambientais negativos. Especificamente, efluentes hospitalares apresentam altas concentrações destes compostos principalmente pela excreção por pacientes. Neste contexto, o presente trabalho visa contribuir com a pesquisa científica em relação a efluentes hospitalares no Brasil, propondo alternativas de tratamento com ozônio para a remoção de fármacos. Para atingir o objetivo proposto, foi realizado um diagnóstico em um hospital visando identificar o consumo das principais classes farmacêuticas. A partir deste estudo, desenvolveu-se um planejamento de experimentos para avaliar os parâmetros mais adequados do processo de ozonização para a remoção de cafeína (CAF), amoxicilina (AMX) e ampicilina (AMP) em soluções aquosas. Foram avaliados experimentalmente os processos O3, O3/UV, O3/Fe2+, O3/UV/Fe2+. Investigou-se a influência da concentração inicial de fármaco, do pH, da potência de luz UV aplicada e da concentração inicial de Fe2+ utilizado como catalisador homogêneo. A variável de resposta foi a eficiência de mineralização. Os parâmetros obtidos pelo planejamento experimental foram aplicados para o Atenolol (ATE) e para soluções aquosas contendo a mistura de todos os compostos analisados (CAF, AMX, AMP e ATE). Um estudo cinético para determinação das constantes de reação foi realizado para a cafeína e atenolol. Para avaliar o tratamento com efluente hospitalar, uma caracterização (detecção de compostos farmacêuticos e parâmetros físico-químicos e toxicológicos) foi realizada antes e após o processo que apresentou a melhor eficiência de mineralização. Com o objetivo de extrapolar os estudos realizados e avaliar outros poluentes emergentes, além dos compostos farmacêuticos, realizaram-se experimentos com 90 compostos como drogas de abuso, hormônios e produtos de higiene pessoal que também podem estar presentes em efluentes hospitalares, avaliando a influência do pH e da dosagem de ozônio aplicada. Como principais resultados, os antibióticos e cardiovasculares foram as classes farmacêuticas mais consumidas no hospital. Pelo planejamento de experimentos, observou-se que todos os compostos avaliados foram rapidamente degradados (100% em menos de 15min) e as melhores eficiências de mineralização atingiram 70,8%, 60,4% e 63,6% para CAF, AMX e AMP, respectivamente. O sistema O3/UV/Fe2+ obteve a melhor eficiência de mineralização para o ATE (67,9%) e para a mistura dos compostos (69,5%). O estudo cinético possibilitou o cálculo das constantes cinéticas: kO3 =697,46 M-1 s-1 e kOH = 6,41x109 M-1 s-1 para a cafeína; e kO3 =146,56 M-1 s-1 e kOH = 15,29x109 M-1 s-1 para o atenolol. A eficiência de mineralização para os experimentos com efluente hospitalar atingiu 54,7% para o sistema O3/UV, sendo eficiente para a completa eliminação de diversos compostos farmacêuticos e remoção da toxicidade. Em relação à remoção dos 90 poluentes emergentes, observou-se que 53,3% dos compostos foram completamente degradados utilizando uma razão mMO3/mMC=0,3 em pH neutro. Os resultados encontrados indicam que o presente trabalho contribui para o avanço da pesquisa sobre efluentes hospitalares, pois apresenta uma alternativa de tratamento eficiente para a completa remoção de diversos compostos farmacêuticos, minimizando o impacto negativo destes no meio ambiente. / Pharmaceutical compounds (PhCs) are detected in various environmental matrices. These compounds, whether not eliminated by advanced treatment techniques, contribute to bacterial resistance and negative environmental impacts on water resource. Specifically, hospital wastewaster exhibit high concentrations of these compounds mainly by the excretion by patients. In this context, this paper aims to contribute to scientific research regarding hospital wastewater in Brazil, proposing treatment alternatives by ozone to remove PhCs. To achieve this purpose, it conducted a diagnosis in a hospital to identify the consumption of major pharmaceutical classes. With this result, it developed an experimental design to evaluate the most appropriate parameters of the ozonation process for the removal of caffeine (CAF), amoxicillin (AMX) and ampicillin (AMP) in aqueous solutions. This study evaluated the following processes experimentally: O3, O3/UV, O3/Fe2+ O3/UV/Fe2+. The influence of ozone dose, initial PhCs concentration, pH, power UV light applied and Fe2+ initial concentration used as homogeneous catalyst were investigated. Mineralization efficiency was the response variable. Parameters obtained by the experimental design were applied for Atenolol (ATE) and aqueous solutions containing the mixture of all compounds analyzed (CAF, AMX, AMP and ATE). A kinetic study for the determination of reaction constants was carried out for caffeine and atenolol. To evaluate the hospital wastewater treatment, a characterization (detection of pharmaceutical compounds and physico-chemical and toxicological parameters) was performed before and after the process that showed the best mineralization efficiency. In order to extrapolate the studies and evaluate other emergent pollutants, in addition to pharmaceutical compounds, were conducted experiments with 90 compounds such as illicit drugs, hormones and personal care products, which also may be present in hospital wastewater, evaluating the influence of pH and ozone dosage. Main results showed that antibiotics and cardiovascular were the most consumed pharmaceutical classes in the hospital. For the design of experiments, it was observed that all the evaluated compounds were rapidly degraded (100% in less than 15 minutes) and the best mineralization efficiency reached 70.8%, 60.4% and 63.6% for CAF and AMX AMP, respectively. The system O3/UV/Fe2+ obtained the best mineralization efficiency for ATE (67.9%) and mixture of compounds (69.5%). The kinetic study allowed the determination of the kinetic constants: kO3 = 697.46 M-1 s-1 and kOH = 6.41x109 M-1 s-1 for caffeine; and kO3 = 146.56 M-1 s-1 and kOH = 15.29x109 M-1 s-1 for atenolol. Mineralization efficiency for hospital wastewater experiments reached 54.7% by the system O3/UV, being efficient for complete elimination of various PhCs and removal of toxicity. Regarding the removal of 90 emergent pollutants, it was observed that 53.3% of the compounds were completely degraded using a ratio mMO3/MMC = 0.3 at neutral pH. The results indicated that this work contributes to the advance of research on hospital wastewater, because it presents an effective alternative treatment for complete removal of various pharmaceutical compounds, minimizing the negative impact on the environment.
2

Degradação de poluentes emergentes por processos oxidativos avançados (O3, O3/UV, O3/Fe2+, O3/UV/Fe2+) visando o tratamento de efluentes hospitalares / Degradation of emergent pollutants by advanced oxidative processes (O3, O3/UV, O3/Fe2+, O3/UV/Fe2+) aiming at hospital wastewater treatment

Souza, Fernanda Siqueira January 2016 (has links)
Compostos farmacêuticos são detectados em diversas matrizes ambientais. Estes compostos, quando não eliminados por técnicas avançadas de tratamento, contribuem para impactos ambientais negativos. Especificamente, efluentes hospitalares apresentam altas concentrações destes compostos principalmente pela excreção por pacientes. Neste contexto, o presente trabalho visa contribuir com a pesquisa científica em relação a efluentes hospitalares no Brasil, propondo alternativas de tratamento com ozônio para a remoção de fármacos. Para atingir o objetivo proposto, foi realizado um diagnóstico em um hospital visando identificar o consumo das principais classes farmacêuticas. A partir deste estudo, desenvolveu-se um planejamento de experimentos para avaliar os parâmetros mais adequados do processo de ozonização para a remoção de cafeína (CAF), amoxicilina (AMX) e ampicilina (AMP) em soluções aquosas. Foram avaliados experimentalmente os processos O3, O3/UV, O3/Fe2+, O3/UV/Fe2+. Investigou-se a influência da concentração inicial de fármaco, do pH, da potência de luz UV aplicada e da concentração inicial de Fe2+ utilizado como catalisador homogêneo. A variável de resposta foi a eficiência de mineralização. Os parâmetros obtidos pelo planejamento experimental foram aplicados para o Atenolol (ATE) e para soluções aquosas contendo a mistura de todos os compostos analisados (CAF, AMX, AMP e ATE). Um estudo cinético para determinação das constantes de reação foi realizado para a cafeína e atenolol. Para avaliar o tratamento com efluente hospitalar, uma caracterização (detecção de compostos farmacêuticos e parâmetros físico-químicos e toxicológicos) foi realizada antes e após o processo que apresentou a melhor eficiência de mineralização. Com o objetivo de extrapolar os estudos realizados e avaliar outros poluentes emergentes, além dos compostos farmacêuticos, realizaram-se experimentos com 90 compostos como drogas de abuso, hormônios e produtos de higiene pessoal que também podem estar presentes em efluentes hospitalares, avaliando a influência do pH e da dosagem de ozônio aplicada. Como principais resultados, os antibióticos e cardiovasculares foram as classes farmacêuticas mais consumidas no hospital. Pelo planejamento de experimentos, observou-se que todos os compostos avaliados foram rapidamente degradados (100% em menos de 15min) e as melhores eficiências de mineralização atingiram 70,8%, 60,4% e 63,6% para CAF, AMX e AMP, respectivamente. O sistema O3/UV/Fe2+ obteve a melhor eficiência de mineralização para o ATE (67,9%) e para a mistura dos compostos (69,5%). O estudo cinético possibilitou o cálculo das constantes cinéticas: kO3 =697,46 M-1 s-1 e kOH = 6,41x109 M-1 s-1 para a cafeína; e kO3 =146,56 M-1 s-1 e kOH = 15,29x109 M-1 s-1 para o atenolol. A eficiência de mineralização para os experimentos com efluente hospitalar atingiu 54,7% para o sistema O3/UV, sendo eficiente para a completa eliminação de diversos compostos farmacêuticos e remoção da toxicidade. Em relação à remoção dos 90 poluentes emergentes, observou-se que 53,3% dos compostos foram completamente degradados utilizando uma razão mMO3/mMC=0,3 em pH neutro. Os resultados encontrados indicam que o presente trabalho contribui para o avanço da pesquisa sobre efluentes hospitalares, pois apresenta uma alternativa de tratamento eficiente para a completa remoção de diversos compostos farmacêuticos, minimizando o impacto negativo destes no meio ambiente. / Pharmaceutical compounds (PhCs) are detected in various environmental matrices. These compounds, whether not eliminated by advanced treatment techniques, contribute to bacterial resistance and negative environmental impacts on water resource. Specifically, hospital wastewaster exhibit high concentrations of these compounds mainly by the excretion by patients. In this context, this paper aims to contribute to scientific research regarding hospital wastewater in Brazil, proposing treatment alternatives by ozone to remove PhCs. To achieve this purpose, it conducted a diagnosis in a hospital to identify the consumption of major pharmaceutical classes. With this result, it developed an experimental design to evaluate the most appropriate parameters of the ozonation process for the removal of caffeine (CAF), amoxicillin (AMX) and ampicillin (AMP) in aqueous solutions. This study evaluated the following processes experimentally: O3, O3/UV, O3/Fe2+ O3/UV/Fe2+. The influence of ozone dose, initial PhCs concentration, pH, power UV light applied and Fe2+ initial concentration used as homogeneous catalyst were investigated. Mineralization efficiency was the response variable. Parameters obtained by the experimental design were applied for Atenolol (ATE) and aqueous solutions containing the mixture of all compounds analyzed (CAF, AMX, AMP and ATE). A kinetic study for the determination of reaction constants was carried out for caffeine and atenolol. To evaluate the hospital wastewater treatment, a characterization (detection of pharmaceutical compounds and physico-chemical and toxicological parameters) was performed before and after the process that showed the best mineralization efficiency. In order to extrapolate the studies and evaluate other emergent pollutants, in addition to pharmaceutical compounds, were conducted experiments with 90 compounds such as illicit drugs, hormones and personal care products, which also may be present in hospital wastewater, evaluating the influence of pH and ozone dosage. Main results showed that antibiotics and cardiovascular were the most consumed pharmaceutical classes in the hospital. For the design of experiments, it was observed that all the evaluated compounds were rapidly degraded (100% in less than 15 minutes) and the best mineralization efficiency reached 70.8%, 60.4% and 63.6% for CAF and AMX AMP, respectively. The system O3/UV/Fe2+ obtained the best mineralization efficiency for ATE (67.9%) and mixture of compounds (69.5%). The kinetic study allowed the determination of the kinetic constants: kO3 = 697.46 M-1 s-1 and kOH = 6.41x109 M-1 s-1 for caffeine; and kO3 = 146.56 M-1 s-1 and kOH = 15.29x109 M-1 s-1 for atenolol. Mineralization efficiency for hospital wastewater experiments reached 54.7% by the system O3/UV, being efficient for complete elimination of various PhCs and removal of toxicity. Regarding the removal of 90 emergent pollutants, it was observed that 53.3% of the compounds were completely degraded using a ratio mMO3/MMC = 0.3 at neutral pH. The results indicated that this work contributes to the advance of research on hospital wastewater, because it presents an effective alternative treatment for complete removal of various pharmaceutical compounds, minimizing the negative impact on the environment.
3

Degradação de poluentes emergentes por processos oxidativos avançados (O3, O3/UV, O3/Fe2+, O3/UV/Fe2+) visando o tratamento de efluentes hospitalares / Degradation of emergent pollutants by advanced oxidative processes (O3, O3/UV, O3/Fe2+, O3/UV/Fe2+) aiming at hospital wastewater treatment

Souza, Fernanda Siqueira January 2016 (has links)
Compostos farmacêuticos são detectados em diversas matrizes ambientais. Estes compostos, quando não eliminados por técnicas avançadas de tratamento, contribuem para impactos ambientais negativos. Especificamente, efluentes hospitalares apresentam altas concentrações destes compostos principalmente pela excreção por pacientes. Neste contexto, o presente trabalho visa contribuir com a pesquisa científica em relação a efluentes hospitalares no Brasil, propondo alternativas de tratamento com ozônio para a remoção de fármacos. Para atingir o objetivo proposto, foi realizado um diagnóstico em um hospital visando identificar o consumo das principais classes farmacêuticas. A partir deste estudo, desenvolveu-se um planejamento de experimentos para avaliar os parâmetros mais adequados do processo de ozonização para a remoção de cafeína (CAF), amoxicilina (AMX) e ampicilina (AMP) em soluções aquosas. Foram avaliados experimentalmente os processos O3, O3/UV, O3/Fe2+, O3/UV/Fe2+. Investigou-se a influência da concentração inicial de fármaco, do pH, da potência de luz UV aplicada e da concentração inicial de Fe2+ utilizado como catalisador homogêneo. A variável de resposta foi a eficiência de mineralização. Os parâmetros obtidos pelo planejamento experimental foram aplicados para o Atenolol (ATE) e para soluções aquosas contendo a mistura de todos os compostos analisados (CAF, AMX, AMP e ATE). Um estudo cinético para determinação das constantes de reação foi realizado para a cafeína e atenolol. Para avaliar o tratamento com efluente hospitalar, uma caracterização (detecção de compostos farmacêuticos e parâmetros físico-químicos e toxicológicos) foi realizada antes e após o processo que apresentou a melhor eficiência de mineralização. Com o objetivo de extrapolar os estudos realizados e avaliar outros poluentes emergentes, além dos compostos farmacêuticos, realizaram-se experimentos com 90 compostos como drogas de abuso, hormônios e produtos de higiene pessoal que também podem estar presentes em efluentes hospitalares, avaliando a influência do pH e da dosagem de ozônio aplicada. Como principais resultados, os antibióticos e cardiovasculares foram as classes farmacêuticas mais consumidas no hospital. Pelo planejamento de experimentos, observou-se que todos os compostos avaliados foram rapidamente degradados (100% em menos de 15min) e as melhores eficiências de mineralização atingiram 70,8%, 60,4% e 63,6% para CAF, AMX e AMP, respectivamente. O sistema O3/UV/Fe2+ obteve a melhor eficiência de mineralização para o ATE (67,9%) e para a mistura dos compostos (69,5%). O estudo cinético possibilitou o cálculo das constantes cinéticas: kO3 =697,46 M-1 s-1 e kOH = 6,41x109 M-1 s-1 para a cafeína; e kO3 =146,56 M-1 s-1 e kOH = 15,29x109 M-1 s-1 para o atenolol. A eficiência de mineralização para os experimentos com efluente hospitalar atingiu 54,7% para o sistema O3/UV, sendo eficiente para a completa eliminação de diversos compostos farmacêuticos e remoção da toxicidade. Em relação à remoção dos 90 poluentes emergentes, observou-se que 53,3% dos compostos foram completamente degradados utilizando uma razão mMO3/mMC=0,3 em pH neutro. Os resultados encontrados indicam que o presente trabalho contribui para o avanço da pesquisa sobre efluentes hospitalares, pois apresenta uma alternativa de tratamento eficiente para a completa remoção de diversos compostos farmacêuticos, minimizando o impacto negativo destes no meio ambiente. / Pharmaceutical compounds (PhCs) are detected in various environmental matrices. These compounds, whether not eliminated by advanced treatment techniques, contribute to bacterial resistance and negative environmental impacts on water resource. Specifically, hospital wastewaster exhibit high concentrations of these compounds mainly by the excretion by patients. In this context, this paper aims to contribute to scientific research regarding hospital wastewater in Brazil, proposing treatment alternatives by ozone to remove PhCs. To achieve this purpose, it conducted a diagnosis in a hospital to identify the consumption of major pharmaceutical classes. With this result, it developed an experimental design to evaluate the most appropriate parameters of the ozonation process for the removal of caffeine (CAF), amoxicillin (AMX) and ampicillin (AMP) in aqueous solutions. This study evaluated the following processes experimentally: O3, O3/UV, O3/Fe2+ O3/UV/Fe2+. The influence of ozone dose, initial PhCs concentration, pH, power UV light applied and Fe2+ initial concentration used as homogeneous catalyst were investigated. Mineralization efficiency was the response variable. Parameters obtained by the experimental design were applied for Atenolol (ATE) and aqueous solutions containing the mixture of all compounds analyzed (CAF, AMX, AMP and ATE). A kinetic study for the determination of reaction constants was carried out for caffeine and atenolol. To evaluate the hospital wastewater treatment, a characterization (detection of pharmaceutical compounds and physico-chemical and toxicological parameters) was performed before and after the process that showed the best mineralization efficiency. In order to extrapolate the studies and evaluate other emergent pollutants, in addition to pharmaceutical compounds, were conducted experiments with 90 compounds such as illicit drugs, hormones and personal care products, which also may be present in hospital wastewater, evaluating the influence of pH and ozone dosage. Main results showed that antibiotics and cardiovascular were the most consumed pharmaceutical classes in the hospital. For the design of experiments, it was observed that all the evaluated compounds were rapidly degraded (100% in less than 15 minutes) and the best mineralization efficiency reached 70.8%, 60.4% and 63.6% for CAF and AMX AMP, respectively. The system O3/UV/Fe2+ obtained the best mineralization efficiency for ATE (67.9%) and mixture of compounds (69.5%). The kinetic study allowed the determination of the kinetic constants: kO3 = 697.46 M-1 s-1 and kOH = 6.41x109 M-1 s-1 for caffeine; and kO3 = 146.56 M-1 s-1 and kOH = 15.29x109 M-1 s-1 for atenolol. Mineralization efficiency for hospital wastewater experiments reached 54.7% by the system O3/UV, being efficient for complete elimination of various PhCs and removal of toxicity. Regarding the removal of 90 emergent pollutants, it was observed that 53.3% of the compounds were completely degraded using a ratio mMO3/MMC = 0.3 at neutral pH. The results indicated that this work contributes to the advance of research on hospital wastewater, because it presents an effective alternative treatment for complete removal of various pharmaceutical compounds, minimizing the negative impact on the environment.
4

Hospital wastewaters treatment : upgrading water systems plans and impact on purifying biomass / traitement des effluents hospitaliers : amélioration des filières de traitement et impacts sur les biomasses épuratoires

Alrhmoun, Mousaab 29 October 2014 (has links)
Cette recherche porte sur l’élimination des micropolluants pharmaceutiques des effluents hospitaliers par des procédés biologiques classiques (boue activée) et membranaire. Il est montré que les systèmes à membrane, externe ou immergée, permettent un meilleur traitement, ou une meilleure rétention, de plus de 50% des molécules pharmaceutiques mesurés. Afin d’améliorer l’efficacité des procédés membranaires, des supports bactériens ont été ajoutés dans le bassin biologique permettant de diminuer considérablement le colmatage. Il est montré qu’une des conséquences de la présence de ce garnissage est une diminution globale des EPS produits, donc du colmatage membranaire, et de la rétention des molécules pharmaceutiques,. Afin d’augmenter encore l’efficacité du procédé, du charbon actif en poudre ou en grain a été ajouté avant la filtration (CAP) ou en sortie de filtration (CAG), permettant une élimination quasi complète des molécules mesurées. La qualité des biomasses épuratrices a été suivie par microscopie confocale avec marquage fluorescent des exopolymères et de la viabilité cellulaire. Il est montré que les effluents hospitaliers modifient la structure des flocs et des biofilms, leur composition biochimique, avec une augmentation des concentrations en protéines extracellulaires, et la répartition des populations caractérisées par métagénomique. / This research investigates the removal of pharmaceutics present in hospital wastewaters by conventional activated sludge and MBR systems of treatment and under various operating conditions to elucidate the removal mechanism and increasing the efficiency of removal. In this study, laboratory scales was composed to four types of reactors used: Bach reactors, conventional activated sludge, submerged membrane bioreactor and extern membrane bioreactor and all these reactors were feed in reel hospital wastewaters. Different Technical studies and many experiments were affected to develop the MBR systems: the beginning was with biofilm supports media and the attached growth of biofilms in the reactor and the finish by using the powder activated carbon. En general, the reported results show high performance for the MBR with compared to CAS system in treating the basic organic pollutants. Presence the biofilm supports media was very important for high removal of pharmaceuticals compounds from the hospital wastewaters. The presence of the pharmaceutical compounds stimulated the mechanisms of survival higher production of EPS. Fouling potential seems to be linked more closely to polysaccharides than other EPS. In this study, for the first time, was employed the confocal microscopy for qualities and quantities analyses for the EPS in the biologic reactors. Microscopic observations were confirmed the chemical analyses of EPS compounds. In final experiment 21 pharmaceuticals were eliminated from the hospital effluents during the treatment in extern membrane (UF) with modified granular activated carbon. In addition to many biomolucles analyses which study the principals impact of hospital effluents on the microorganism’s especially the bacteria in using different, recent techniques. This study demonstrates by reel conditions the role the developed MBR systems in treating the hospital effluents and its impact direct on the environment.
5

Étude de l'applicabilité des POCIS (Polar Organic Chemical Integrative Sampler) au dosage des résidus de médicaments dans les effluents hospitaliers / Study of the applicability of POCIS (Polar Organic Chemical Integrative Sampler) for monitoring pharmaceuticals in hospital wastewater

Bailly, Emilie 08 April 2013 (has links)
L’évaluation des risques environnementaux et sanitaires liés à la présence de résidus de médicaments dans l’environnement, représente un enjeu majeur en particulier au regard de la gestion du cycle des usages de l’eau. Les effluents des établissements de soins représentent une source non négligeable de pollution et justifient le développement de techniques spécifiques de mesures des émissions de résidus de médicaments dans leurs eaux usées. Dans le cadre de ces développements de méthode, l'échantillonnage représente une des difficultés majeures car la matrice brute des eaux en sortie des hôpitaux est très chargée en matières organiques, les débits sont extrêmement variables, les sites de prélèvement sont difficiles d'accès et il existe une forte variabilité des dispensations des traitements jour/nuit et semaine/week-ends. Les échantillonneurs intégratifs apparus récemment, offrent une alternative intéressante aux stratégies d’échantillonnage existantes, permettant d'effectuer un suivi moyenné sur de longues périodes d'observation associé à une simplicité d'usage et une réduction des coûts. Ce travail porte sur l’étude de l’applicabilité des échantillonneurs intégratifs POCIS (Polar Organic Chemical Integrative Sampler) au dosage des résidus de médicaments dans les effluents hospitaliers. Ce dispositif a principalement été utilisé dans les eaux de surface et les effluents de STEP et son application dans les eaux usées reste rare. 6 molécules déjà identifiées comme représentatives des grandes familles de médicaments utilisés à l'hôpital (Aténolol, Prednisolone, Méthylprednisolone, Sulfaméthoxazole, Ofloxacine, Kétoprofène) ont été retenues.Les cinétiques d’adsorption des molécules sur les POCIS ont été suivies en laboratoire en condition de maitrise des paramètres les plus influents : température, vitesse de l’eau, charge en matière organique, colmatage…Ce calibrage a pour but de déterminer le coefficient d’échantillonnage Rs (L/j) spécifique à chaque molécule et nécessaire au calcul de la concentration dans le milieu d’exposition du POCIS. Nous avons observé une augmentation des Rs quand la vitesse de l'eau augmente ou quand la température augmente. Dans les eaux usées, la valeur de Rs est plus faible et la durée de la phase linéaire est réduite comparée à l'eau du robinet. Pour ce type d'application, la période d'exposition ne devra pas dépasser 4 à 5 jours en raison du colmatage des membranes et d'une teneur élevée en particules organiques dissoutes. Après calibrage dans l’eau du robinet et dans l’eau usée, les POCIS ont été exposés in situ dans un effluent hospitalier pour mesurer les concentrations en 6 molécules ciblées. Cinq ont pu être quantifiées et les concentrations calculées à partir des extraits des POCIS sont concordantes avec celles obtenues par prélèvement direct d’un échantillon moyenné d’eaux usées. Le facteur limitant réside dans les difficultés d’accès au site et la présence de solides dans le collecteur d'eaux usées. Ce travail ouvre des perspectives quant à l'application des POCIS pour les effluents hospitaliers et pourra à terme contribuer à l'acquisition de données pour une meilleure surveillance des rejets. / The assessment of the environmental and public health risks due to pharmaceutical residues, is a main issue particularly in the light of water cycle management and water resources. Hospitals are supposed to be a main source of pollution and the assessment of their contribution to the overall pharmaceutical pollution is necessary. Monitoring the pharmaceutical loads in hospital sewage is a great challenge because of the difficulties which have to be overcome to obtain representative samples: high organic content and suspended solids, wastewater flow variations, difficult access to sampling sites, variations of pharmaceutical release throughout the day resulting from hospital activities. An interesting alternative way is to use passive samplers, which allow for the measurement of Time Weighted Average (TWA) concentrations, overcoming many shortcomings of the spot sampling techniques. The aim of this work is to evaluate the applicability of POCIS for the monitoring of pharmaceuticals in hospital wastewater. This tool is mainly used for surface water or WWTP effluent and its application for wastewater sampling remains scarce. This study was conducted on six compounds already selected as representative of some of the main class of pharmaceuticals used at the hospital (Atenolol, Prednisolone, Methylprednisolone, Sulfamethoxazole, Ofloxacin, Ketoprofen). POCIS were calibrated for the analytes of interest in tap water and wastewater in laboratory conditions close to relevant environmental conditions (temperature, flow velocity, fouling). Sampling rates (Rs) were determined and we observed a significant increase with flow velocity and temperature. Whatever the compound, the Rs value was lower in wastewater and the linear phase of uptake was shorter than in tap water. A five-day period was defined as the optimal duration for POCIS exposition in wastewater.POCIS were then deployed in a hospital sewage pipe during four days and the estimated water concentrations were close to those measured in twenty-four hour composite samples, carried out with an autosampler.This work gives encouraging results for the deployment of POCIS in wastewater that could be a useful tool for pharmaceutical pollution management.
6

Βeta-bloqueadores em efluente hospitalar: ocorrência, degradação por processos avançados de oxidação e identificação de subprodutos / Βeta-blockers in hospital wastewater; occurence, degradation by advanced oxidation process and byproducts identification

Wilde, Marcelo Luís 15 December 2011 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / β-Blockers are an important group of prescription drugs; as a consequence of the large and continuous use, they are commonly found in the environment. This study assessed, preliminary, the inherent risk of the β-blockers Atenolol, Metoprolol and Propranolol, mostly used in the University Hospital of Santa Maria (HUSM), and showed that Propranolol has high Risk Quotient (RQ) of 0.56. HPLC-FLD and SPE methodologies were developed and optimized with the aid of experimental design in order to analyze the occurrence of β-blockers in the HUSM sewage system. The average concentration for Atenolol, Metoprolol and Propranolol found for a week sampling were 2.45, 4.67 and 0.70 μg L-1 in the sewage of the Emergence; 0.95, 0.70 and 0.315 μg L-1 in the HUSM main sewage, and 1.26, 1.27 and 0.56 μg L-1 in the water course receptor, respectively, As possible remediation methodologies for the Hospital Wastewater (HWW) were investigated Advanced Oxidation Process (AOPs) such as photo-Fenton, K2FeO4, Ozonation and O3/Fe2+. The operational parameters were optimized by Response Surface Methodology (RSM). Using optimized conditions for photo-Fenton, Atenolol, Metoprolol and Propranolol were totally degraded in 5 min in aqueous solution, and the mineralization achieved 80% after 120 min of treatment. In HWW, the β-blockers were also totally degraded, however, only 26.5% of the organic matter and 38.6% of the aromaticity were removed. The ready biodegradability and toxicity of the photo-Fenton s samples were estimated by official methods, which indicated an increase in the biodegradability and toxicity. This behavior may be correlated to the formation of degradation products (DPs), relatively, more toxic. The DPs were identified with aid of Liquid Chromatography tandem Mass Spectrometry (LC-MSn). Other proposed degradation process was oxidation-coagulation using Fe(VI), which achieved above 90% degradation for Atenolol, Metoprolol and Propranolol in HWW, while only 17% COD and 60% aromaticity removal. In aqueous solution this process led to 71.7%, 24.7% and 96.5% degradation of Atenolol, Metoprolol and Propranolol, respectively. No mineralization was found, indicating the formation of DPs, identified by LC-MSn. The ready biodegradability of the post-process samples was tested and the results showed that the oxidation-coagulation with Fe(VI) increased the biodegradability. The applicability of ozonation was evaluated varying the pH (3-11) for HWW and aqueous solution. More than 95% of the β-blockers were degraded independently of the initial pH, while above 50% of the aromaticity was removed. In aqueous solution the β-blockers were degraded in 10 min treatment and the identification of the DPs were carried out for process pH 5, 7 and 9. Catalytic ozonation (O3/Fe2+) was applied to HWW and a mineralization of 49% was achieved, with 77.9% aromaticity removal. The β-blockers were totally degraded. Therefore, the present study represents a high qualified analytical information contribution concerning the occurrence of β-blockers in HWW. The studied AOPs/Fe(VI) processes demonstrated to be suitable to degrade Atenolol, Metoprolol and Propranolol. Moreover, high removal of organic matter and aromaticity were achieved by appling O3/Fe2+ process. In many aspects, this work can be considered original, in especial, by regarding the application of Ferrate(VI) and Catalytic Ozonation to the degradation of β-blockers in HWW. / Os β-bloqueadores são uma importante classe de fármacos prescritos na terapia de doenças cardiovasculares e como consequência de seu grande e contínuo uso são comumente encontrados no meio ambiente. O presente estudo avaliou preliminarmente o risco inerente dos β-bloqueadores mais usados no Hospital Universitário de Santa Maria (HUSM), Atenolol, Metoprolol e Propranolol, evidenciando que Propranolol apresentou maior risco inerente com Quociente de Risco teórico de 0,56 (risco médio). Métodos HPLC-FLD e de clean-up/pré-concentração por SPE foram desenvolvidos e otimizados com auxílio de Metodologia de Superfície de Resposta (RSM) para avaliar a ocorrência de β-bloqueadores no sistema de esgotos do HUSM. A concentração ambiental mensurada para Atenolol, Metoprolol e Propranolol durante um ciclo semanal no ponto de lançamento Efluente PA foi 2,45; 4,67 e 0,70 μg L-1, no ponto HUSM principal 0,95; 0,70 e 0,32 μg L-1 e para o Córrego onde os efluentes são lançados de 1,26; 1,27 e 0,56 μg L-1, respectivamente. Como metodologia de remediação da contaminação de β-bloqueadores em Efluente Hospitalar (EH) foram investigados os Processos Avançados de Oxidação (PAOs) Foto-Fenton, K2FeO4, Ozonização e O3/Fe2+. Os parâmetros operacionais foram otimizados por RSM. Usando as condições otimizadas para o processo Foto-Fenton, Atenolol, Metoprolol e Propranolol foram totalmente degradados em 120 min de tratamento, contudo somente 26,5 e 38,6% da carga orgânica e aromaticidade, respectivamente, foram removidos em EH. A pronta biodegradabilidade e toxicidade para amostras aquosas do processo Foto-Fenton foram analisadas por métodos oficiais e indicaram aumento na biodegradabilidade e toxicidade. Este comportamento esta relacionado à formação de Produtos de Degradação (PD) relativamente mais tóxicos. Os PDs foram identificados por Cromatografia Líquida acoplada a Espectrometria de Massas (LC-MSn). Outro processo proposto foi oxidação-coagulação com Fe(VI) que alcançou degradação de Atenolol, Metoprolol e Propranolol acima de 90% em EH, enquanto apenas 17 e 60% da matéria orgânica e aromaticidade foram removidos, respectivamente. Em solução aquosa este processo conduziu a degradação de 71,7; 24,7 e 96,5% de Atenolol, Metoprolol e Propranolol, respectivamente. Nenhuma mineralização foi encontrada indicando a formação de PDs, identificados por LC-MSn. A pronta biodegradabilidade para as amostras aquosas pós-processo foram avaliadas e os resultados encontrados mostraram que houve aumento na biodegradabilidade. A aplicabilidade de ozonização foi avaliada variando o pH de 3-11 em EH e solução aquosa. Mais de 95% dos β-bloqueadores foram degradados independente do pH inicial, enquanto mais de 50% da aromaticidade e 30% da matéria orgânica foram. Em solução aquosa todos os β-bloqueadores foram degradados em menos de 10 min e para os processos em pH 5, 7 e 9 foram identificados os PDs. O processo de O3/Fe2+ alcançou 49% de remoção de matéria orgânica, 77,9% de redução da aromaticidade e completa degradação de Atenolol, Metoprolol e Propranolol em EH. Portanto, o presente estudo contribui com informação analítica qualificada sobre a ocorrência de β-bloqueadores em EH. Os processos de degradação estudados mostraram-se adequados para a degradação de Atenolol, Metoprolol e Propranolol. Ademais, a maior remoção de matéria orgânica e aromaticidade foram observadas para o processo de O3/Fe2+. Em muitos aspectos, este trabalho pode ser considerado original, em especial sobre a aplicação de ferrato(VI) e ozonização catalítica para a degradação de β-bloqueadores em EH.