• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 833
  • 523
  • 82
  • 45
  • 31
  • 24
  • 21
  • 21
  • 20
  • 20
  • 19
  • 17
  • 13
  • 12
  • 11
  • Tagged with
  • 1885
  • 853
  • 745
  • 493
  • 257
  • 239
  • 196
  • 185
  • 175
  • 148
  • 141
  • 134
  • 133
  • 128
  • 115
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
321

Estudo das dimensões da papila gengival em áreas ântero-superiores adjacentes a implantes unitários

Perez, Fabiano [UNESP] 08 August 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:35:10Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-08-08Bitstream added on 2014-06-13T19:05:27Z : No. of bitstreams: 1 perez_f_dr_arafo.pdf: 633248 bytes, checksum: f36ddc620369a8183bf9e6e87d8c059f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / O objetivo deste trabalho foi o de comparar as dimensões da papila gengival em áreas restauradas com implantes unitários e áreas com a dentição natural hígida. Além disso, verificou-se a influência da distância da crista óssea até o ponto de contato e da distância da plataforma do implante até a parede axial do dente adjacente sobre a extensão da papila gengival. Para isso, foram selecionados um total de 45 áreas proximais entre dentes naturais e 46 áreas proximais com a presença de implantes unitários. Os pacientes eram, então, submetidos a um exame clínico que tinha por objetivo a constatação da presença total, parcial, ou a ausência da papila gengival nas áreas examinadas. A papila gengival era então classificada em 4 níveis de altura: 0, quando estava totalmente ausente; 1 quando a papila ocupava menos da metade da distância da sua base até o ponto de contato; 2 quando a papila ocupava mais da metade dessa mesma distância, porém não preenchia totalmente o espaço interproximal; e 3 quando todo o espaço interproximal era ocupado pela papila gengival. Depois do exame clínico, os pacientes eram submetidos a tomadas radiográficas sendo que uma tela milimetrada era adaptada junto ao filme para que a imagem radiográfica obtida pudesse ser mensurada mais satisfatoriamente. Depois de obtidas as radiografias, as radiografias foram digitalizadas e as distâncias referentes ao estudo foram feitas por meio de um programa de computador. Com a análise dos dados obtidos, permitiu-se concluir que áreas anteriores superiores restauradas com implantes tendem a apresentar uma papila gengival com menor dimensão do que áreas de dentição natural. / The purpose of this work was to compare the interproximal dental papilla dimension in areas restored with single implants and in areas of natural dentition. The effect of the distance from the contact point to the bone crest and of the distance from the implant platform to the axial face of the adjacent tooth on the papilla extension was also evaluated. Forty five interdental areas and 46 inter-implant areas were selected for the study. The presence (total or partial) or the absence of the interproximal papilla were examined and the following punctuations were made: 0 when the papilla was completely absence; 1 when the papilla filled less then half of the distance between its base and the contact point; 2 when the papilla filled more then half of that distance but not filled the entire of the interdental space; 3 when the whole interdental space was filled by the papilla. After the clinical examination, the patients were submitted to radiographic exams, using a radiographic grid adapted to the film to improve the measurements. The radiographs images were then digitized and the distances related to the study were measured using a computer software. From the data obtained, it was concluded that maxillary anterior areas restored with implants tend to present a smaller interdental papilla then areas of natural dentition. The distance from the contact point to the bone crest (height), the distance between adjacent roots in the natural dentition and the distance between the implant platform and the adjacent root (width) had significant influence on the presence or absence of the interproximal papilla in both groups evaluated.
322

Usinabilidade e integridade superficial de implantes dentários

Manera, Rodolfo da Silva [UNESP] 31 January 2014 (has links) (PDF)
Made available in DSpace on 2015-05-14T16:53:02Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-01-31Bitstream added on 2015-05-14T16:59:32Z : No. of bitstreams: 1 000825077.pdf: 1075325 bytes, checksum: 119b03cd57fb8fa0c0fee869067e2d35 (MD5) / Ligas metálicas destinadas a implantes, de um modo geral, têm sido cada vez mais pesquisadas quanto às suas propriedades mecânicas, microestruturais e características de biocompatibilidade. Apesar do surgimento de inúmeros materiais poliméricos, o titânio e suas ligas representam ainda a grande gama de aplicações na área da implantodontia. O titânio é considerado um material de difícil usinabilidade, pois desenvolve altas tensões e temperaturas em uma área de corte 2/3 menor que a de outros materiais. Assim, os parâmetros de usinagem e a ferramenta de corte necessitam ser adequadamente especificados, pois tanto a matéria-prima quanto o processo de fabricação levam a um alto valor agregado do produto final. Este trabalho determinou os efeitos da velocidade de corte e da profundidade de usinagem na usinabilidade (força de corte e energia específica de corte) e integridade superficial (microdureza e acabamento) no roscamento de implantes dentários de titânio comercialmente puro (grau 4, ASTM F67). Os ensaios foram realizados em torno CNC de cabeçote móvel, empregando ferramenta de metal duro revestida de TiAlN e fluido de corte abundante. Com base na Análise de Variância (ANOVA), os resultados mostraram que os parâmetros de corte afetam a usinabilidade e a integridade superficial da rosca, sendo a profundidade de usinagem o fator mais influente. Níveis muito baixos ou altos da profundidade de usinagem elevam a energia específica e a força de corte, respectivamente, encruando a subsuperfície da rosca e prejudicando a rugosidade dos flancos dos filetes. Velocidades de corte menores tendem a aumentar a força e a energia específica de corte, prejudicando o acabamento da rosca, mas não influem em sua dureza. Rugosidades estatísticas Skewness e Kurtosis apontaram a prevalência de picos agudos na superfície da rosca, favorecendo a osseointegração. Testes na condição High-Speed Cutting (HSC) indicaram ... / Metallic alloys applied to implants have been researched aiming at improving their mechanical properties, microstructure and biocompatibility. Despite appearing several types of polymers in the last years, titanium and its alloys are still used extensively in the implantology. Titanium is considered a hard-to-cut material, because it develops high stresses and temperatures in a small cutting area (2/3 smaller than for other materials). Thus cutting parameters and tools need to be specified properly, since both raw material and manufacturing process increase the costs of the final product. This research determined the effects of cutting speed and depth of cut on machinability (cutting force and specific cutting energy) and surface integrity (microhardness and roughness) when threading pure commercially dental implants (grade 4, ASTM F67). Machining tests were carried out in a CNC lathe by applying TiAlN coated carbides and cutting fluid. Based on Analysis of Variance (ANOVA), the main results indicated that cutting parameters influence on machinability and surface integrity of the implant screw, being depth of cut the more influent. Low and high levels of depth of cut increase specific cutting energy and cutting force, respectively, hardening the screw subsurface and damaging the roughness of the thread flanks. Lower cutting speeds trend to raise both cutting force and specific cutting energy, damaging the screw finishing, but they do not affect its subsurface microhardness. Skewness and Kurtosis roughness parameters indicated the predominance of spiky surface on screw which is favorable to osseointegration. Tests at High-Speed Cutting (HSC) showed it is possible to machine implant screws, but depth of cut cannot be high so that avoiding vibration in threads
323

Efeito da aplicação de filmes de carbono tipo diamante por plasma no destorque de pilares de implantes com conexões cônicas internas

Coelho, Arianne Vallim Pinto [UNESP] 07 August 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:24Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-08-07. Added 1 bitstream(s) on 2015-06-18T12:48:55Z : No. of bitstreams: 1 000826366.pdf: 2139319 bytes, checksum: 7c1587e5da8c47a208fed4769c228802 (MD5) / O estudo avaliou o efeito da aplicação de dois filmes de Carbono tipo Diamante por plasma no torque reverso dos pilares protéticos submetidos à ciclagem mecânica e analisou a adaptação do pilar e de suas roscas em relação ao implante, bem como a deformação gerada nas roscas dos pilares e nas roscas internas dos implantes. Para tal, foram utilizados 60 conjuntos de implantes de conexão cônica interna (CCI) de 11º e 8º e pilares de corpo único de titânio que foram divididos em seis grupos (n=10): GC-8 (controle) - CCI 8º sem tratamento; DLC-8 - CCI 8º com aplicação de filme de carbono tipo diamante (DLC); AgDLC-8 - CCI 8º com aplicação de filme de carbono tipo diamante dopado com nano partículas de prata (AgDLC); GC-11 (controle) - CCI 11º sem tratamento; DLC-11 - CCI 11º com aplicação de filme de carbono tipo diamante (DLC); AgDLC-11 - CCI 11º com aplicação de filme de carbono tipo diamante dopado com nano partículas de prata (AgDLC). Os filmes foram depositados por meio do processo de Deposição Química a Vapor Assistida por Plasma (PECVD). Os pilares receberam o aperto controlado por um dispositivo de controle de torque digital seguindo as recomendações do fabricante. O teste de fadiga foi conduzido seguindo os parâmetros especificados na norma ISO 14801 com uma carga de 120 Ncm a 2 Hz por 2 x 106 ciclos. Ao final dos ciclos, o valor de destorque dos pilares foi registrado. Análises por Microscopia Eletrônica de Varredura (MEV) foram realizadas em três amostras de cada grupo, antes e após a ciclagem mecânica, para verificar se a adaptação do pilar (corpo e roscas) ao implante foi afetada pela aplicação dos filmes. A caracterização dos filmes foi realizada por meio de análises Tribológicas, bem como por Espectroscopia Raman e Espectrometria de Energia Dispersiva de Raios-X (EDS). Todos os grupos mostraram redução nos valores de torque reverso. O grupo DLC-8 foi o ùnico a apresentar... / This study evaluated the effect of the plasma deposition of two diamondlike carbon thin films (DLC) on the reverse torque and adaptation of prosthetic abutments after mechanical cycling. Sixty sets of 11º e 8º tapper connection implants (TCI) and titanium solid abutments were divided in six groups (n=10): GC-8 (control) - 8º TCI with no film deposition; DLC-8 - 8º TCI with DLC deposition; AgDLC-8 - 8º TCI with silver doped DLC (AgDLC); GC-11 (control) - 11º TCI with no film deposition; DLC-11 - 11º TCI with DLC deposition; AgDLC-11 -11º TCI with silver doped DLC (AgDLC); The films were deposited by Plasma Enhanced Chemical Vapor Deposition (PECVD) process. The abutments were tightened with a controlled torque meter device following the manufacturer's recommendations. Mechanical cycling was carried out with a load of 120 Ncm during 2 x 106 cycles with a frequency of 2 Hz (ISO 14801). Afterwards, detorque was measured. Analyses with Scanning Electron Microscopy (SEM) were conducted on three samples of each group before and after mechanical cycling in order to verify the adaptation of the abutments (body and threads). Tribology analyses, as well as Raman Spectroscopy and Energy-Dispersive X-rays Spectroscopy (SDS) analyses were performed for characterization of the different surface treatments. All groups demonstrated reduction of reverse torque values. DLC-8 was the only group that showed an increase on the average reverse torque values
324

Efeito da administração de alendronato, a longo prazo, sobre as propriedades mecânicas do tecido ósseo, sua reparação e mineralização ao redor de implantes osseointegráveis. Estudo em ratas

Verzola, Mario Henrique Arruda [UNESP] 28 March 2014 (has links) (PDF)
Made available in DSpace on 2015-06-17T19:34:28Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-03-28. Added 1 bitstream(s) on 2015-06-18T12:48:48Z : No. of bitstreams: 1 000830290_20170328.pdf: 71548 bytes, checksum: 1482e1bc5082299166a7c62f366c8a4f (MD5) Bitstreams deleted on 2017-03-31T12:19:17Z: 000830290_20170328.pdf,. Added 1 bitstream(s) on 2017-03-31T12:20:21Z : No. of bitstreams: 1 000830290.pdf: 1153430 bytes, checksum: cfa5ae52217192f227b37867f3b21bd4 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo teve como objetivo avaliar, em ratas, o efeito da terapia a longo prazo com bifosfonato sobre o processo de reparo e mineralização óssea ao redor de implantes e sobre as propriedades mecânicas do tecido ósseo. Para isso, 160 ratas foram distribuídas aleatoriamente em 2 grupos: grupo alendronato (ALD), no qual os animais receberam administração subcutânea de alendronato uma vez por semana, e grupo controle (CTL), no qual os animais receberam administração semanal de placebo, durante todo o período experimental. Após 120 dias do início do tratamento, um implante de titânio foi instalado na metáfise tibial, de ambos os lados. Dez animais de cada grupo foram sacrificados nos dias 5, 10, 15, 20, 25, 30, 45 e 60 pós-cirurgia, sendo retirados os fêmures e as tíbias. Os fêmures foram avaliados quanto à densitometria óssea e testes mecânicos. As tíbias contendo os implantes foram avaliadas quanto ao torque de remoção, análise histométrica (%BIC e %BAFO), microscopia eletrônica de varredura (MEV) e espectroscopia de energia dispersiva de raios-X (EDS), mapeamento da mineralização além de arranjo e distribuição do colágeno. Os resultados quanto à densitometria óssea demonstraram maiores valores para os animais do grupo ALD em relação ao grupo CTL, em todos os períodos de avaliação, com exceção do período de 15 dias. Os resultados dos testes mecânicos, de forma geral, demonstraram maior resistência à fratura (força máxima) e maior capacidade de absorção de energia (tenacidade) no grupo ALD em relação ao grupo CTL até o período de 45 dias. Para a rigidez, no período de 45 dias o grupo ALD apresentou valores significativamente maiores, entretanto sem diferença entre os grupos aos 60 dias. Em relação à resiliência, o grupo ALD demonstrou valores significativamente maiores somente no período de 45 dias. A droga influenciou no torque de remoção... (Resumo completo, acesse link abaixo) / The aim of this study was evaluate in female rats, the effect of long-term therapy with bisphosphonate on the healing process and bone mineralization around implants and on the mechanical properties of bone tissue. One hundred sixty female rats were randomly allocated into two equally sized groups: the alendronate (ALD) group, which received the subcutaneous administration of alendronate (1 mg/kg/week), and the control (CTL) group which the animals received weekly the subcutaneous administration of saline solution (placebo) for the entire experimental period. After 120 days of the treatment initiation, in the booth groups, one titanium implant was installed in the tibia metaphysis. Ten animals in each group were euthanized at: 5, 10, 15, 20, 25, 30, 45, or 60 days after surgery, and their femurs and tibias were removed. The femurs were evaluated regarding bone mineral density (BMD), and mechanical tests. The tibias samples with the implants were evaluated by removal torque, histometric analysis (% BIC and % BAFO), scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS), mapping of mineralization and arrangement and distribution of the collagen. The results regarding bone densitometry showed higher values for the animals of ALD group compared with the CTL group at all evaluation periods, except for the period of 15 days. The results of mechanical tests, in general, showed higher fracture resistance (maximum force) and higher capacity of energy absorption (tenacity) in the ALD group compared with the CTL group until the 45 day. In the 45 days, the stiffness showed significantly higher values in the ALD group, however at 60 days no difference was observed between the groups. Regarding the resilience, the ALD group showed significantly higher values in the 45 days. The drug influenced the removal torque of implants with significantly higher values for ALD group until ...(Complete abstract electronic acess below)
325

Distribuição das tensões em próteses protocolo mandibulares com diferentes extensões de cantilever e material de revestimento oclusal

Medeiros, Rodrigo Antonio de [UNESP] 17 February 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:30Z (GMT). No. of bitstreams: 0 Previous issue date: 2014-02-17Bitstream added on 2015-03-03T12:06:36Z : No. of bitstreams: 1 000799687.pdf: 2318580 bytes, checksum: 6de6ec46da88b8b9d6b603ce2ab8f4be (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste estudo objetivamos a avaliação da distribuição de tensões na interface osso/implante, por meio do método da fotoelasticidade, em próteses mandibulares tipos protocolos de Branemark, com diferentes extensões de cantilever, materiais de recobrimento estético e uso de intermediários. Foi confeccionado um modelo fotoelástico de uma mandíbula edêntula, contendo cinco implantes 4.0x13 mm hexágono externo (HE) entre os forames mentonianos. Os grupos foram divididos da seguinte forma: Grupo 1 – UCLA e barra metálica; Grupo 2 – UCLA e revestimento oclusal em resina acrílica; Grupo 3 – UCLA e revestimento em cerâmica; Grupo 4 – Intermediário e barra metálica; Grupo 5 – Intermediário e revestimento em resina acrílica; Grupo 6 – Intermediário e revestimento em cerâmica. Com auxílio de uma máquina de ensaio EMIC inicialmente as forças de 70 N foram aplicadas em um ponto anterior, no implante mais posterior e em diferentes extensões de cantilever (até 37,5mm do último implante) na barra metálica e posteriormente nas próteses confeccionadas com barra metálica e revestimento em cerâmica e resina acrílica. Por meio de imagens fotográficas e auxílio do programa Adobe Photoshop CS6 nas imagens obtidas após o teste foi realizada a análise das tensões de acordo com o número de franjas de alta intensidade e de acordo com a concentração e área de distribuição dessas tensões nos grupos testados. Os resultados mostraram um maior número de franjas de alta tensão com o aumento do cantilever, e melhor distribuição das tensões foram para os grupos com as próteses confeccionadas em resina acrílica e para os grupos que continham componente intermediário. Concluímos que o uso de intermediários com próteses protocolo em resina acrílica e a ausência do cantilever tende a apresentar menores números de franjas de alta tensão ao redor dos implantes / The aim of this study was to assess the stress distribution, through photoelastic method, on mandibular implant-supported prostheses (Brånemark protocol), associated with different cantilever lengths, aesthetic coating materials and implant abutment. One photoelastic model of an edentulous mandible was made. The model contained five external hexagon implants (HE) with 4.0mm diameters and 13mm lengths placed between the mental foramen. The groups were divided as follows: Group 1 - UCLA and metal bar; Group 2 - UCLA and occlusal acrylic resin coating; Group 3 - UCLA and porcelain coating; Group 4 - Abutment and metal bar; Group 5 - Abutment and acrylic resin coating; Group 6 - Abutment and porcelain coating. A force was applied, using a universal testing machine (EMIC), in different regions - in the most anterior implant, in the most posterior implant and in different cantilever extensions (up to 37.5 mm from the last implant) - in the metal bar and later in the metal bar with porcelain and acrylic resin coated prostheses. The results were obtained through photograph images and the Adobe Photoshop CS6 software was used for qualitative analysis. The analysis was performed according to the number of fringes with high intensity and to the stress distribution area. The results showed a greater number of high stress fringes as the cantilever extension increases. Groups with acrylic resin coating and with abutments exhibited greater stress distribution. We concluded that the use of abutments in acrylic resin protocol prostheses and the absence of the cantilever tends to decrease stress around implants / FAPESP: 12/11336-7
326

Análise da distribuição das tensões em próteses protocolo mandibulares com estruturas fresadas por CAD/CAM e confeccionadas pela técnica convencional : análise pela fotoelasticidade e extensometria /

Medeiros, Rodrigo Antonio de. January 2016 (has links)
Orientador: Marcelo Coelho Goiato / Banca: Aldiéris Alves Pesqueira / Banca: Daniela Micheline dos Santos / Banca: Marcela Filié Haddad / Mario Alexandre Coelho Sinhoreti / Resumo: O objetivo desse estudo foi avaliar a distribuição de tensão, por meio dos métodos fotoelástico e extensometria, em próteses p rotocolo mandibulares (tipo Branem ä rk) com infra estruturas confeccionadas com difer entes materiais e técnica s, sob força de compressão. Foi confeccionado um modelo fotoelástico de uma mandíbula edêntula que recebeu cinco implantes 4x11 mm hexágono externo entre os forames mentonianos. Os gr upos foram divididos em: Grupo I - infraestrutur a fundida em níquel - cromo com revestimento ocl usal em resina acrílica (n=7); Grupo II - infra estrutura fundida em níquel - cromo com revestimen to oclusal em cerâmica (n=7); Grupo III - infra estrutura fresada em Zircônia estabilizada por óxido de í trio com revestimento em cerâmica (n=7). Inicialmente, foi realizado o teste da fotoelasticidade e, posteriormente, a extensometria. Pela metodologia da fotoelasticidade, c om auxílio de uma máquina de ensaio universal (EMIC) foram aplicadas cargas axiais d e 70 N na região do implante mais anterior, entre os incisivos, e no centro do primeiro molar de cada lado. Por meio de imagens fotográficas e com o auxílio do programa Adob e Photoshop CS6, as imagens foram analisadas de acordo com o número de franjas de a lta intensidade nos grupos testados. Para a Tese de Doutorado Resumo metodologia da extensomet ria, as cargas foram aplicadas da mesma maneira da metodologia da fotoelasticidade e a medição das tensões foi realizada em duas regiões distintas. Para a primeira região, dois extensômet r os elétricos de resistência foram posicionados horizontalmente na região mesial e distal dos cinco implantes, diretamente sobre a crista marginal do modelo fotoelástico. Para a segunda re gião, a resina fotoelástica foi removida d a superfície vestibular e lingual de cada implante, sendo mantida1 mm de resina (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed to evaluate the stress distribution in full - arch fixe d mandibular prosthesis (Branemä rk type) with infrastructure made of different materials and techniques, and under compressive force, through photoelastic and strain gauge analysis. A photoelastic cast of an edentulous jaw was fabricated and received five ex ternal hexagon implants (4x11mm) between the mental foramen. The groups were divided into: Group I - Nickel - Chrome fused infrastructure with acrylic resin occlusal coating; Group II - Nickel - Chrome fused infrastructure with ceramic occlusal coating; Group III - Yttria - stabilized zirconia fused infrastructure with ceramic coating. First, the photoelastic analysis was performed and later the strain gauge analysis. A force of 70 N was applied by using a testing machine (EMIC) in the region of the most anterior implant, between incisors, and in the center of the first molar on each side. The images were analyzed by a blinded evaluator through images and by using Adobe Photoshop CS6, according to the number of high intensity fringes in each group. Regarding the s train gauge analysis, the stress measure was performed in two distinct regions. For the first region, two resistance strain gauges were placed horizontally in the mesial and distal regions of the five Tese de Doutorado Abstract implants, directly on the marginal ridge of the photoel astic cast. For the second region, the photoelastic resin was removed on the buccal and lingual surfaces of each implant, leaving 1 mm of intact resin, where the strain gauges were placed vertically. The same compression tests described above were carried out. Data were submitted to two - way ANOVA and to the Tukey post - hoc test with 5% level of significance. The results of both methods showed lower stress values for Group I, when compared to other groups. It can be concluded (Complete abstract electronic access below) / Doutor
327

Efeito da plataforma Switching sobre os tecidos peri-implantares : estudo experimental em cães /

Scala, Alessandro. January 2011 (has links)
Orientador: Daniele Botticelli / Banca: Wilson Roberto Poi / Banca: Idelmo Rangel Garcia Júnior / Banca: Márcio de Moraes / Banca: Thaís da Silveira Rodrigues / Resumo: Objetivo: Avaliar a influência da plataforma Switching sobre a remodelação dos tecidos peri-implantares. Material e métodos: Em 6 cães labradores, foram extraídos os pré-molares e primeiro molares inferiores bilateralmente. Após 3 meses de cicatrização, na região correpondente ao 1º molar, foi instalado um implante cônico em cada lado da mandíbula, com o ombro do mesmo posicionado ao nível da crista óssea alveolar vestibular. No lado direito da mandíbula, foi utilizado um pilar de diâmetro reduzido em relação à plataforma do implante, criando uma incompatibilidade de 0,85 milímetros (grupo teste), enquanto no lado esquerdo selecionou-se um pilar do mesmo diâmetro da plataforma do implante (grupo controle). Os retalhos foram suturados permitindo a cicatrização não-submersa. Após 4 meses, os animais foram eutanasiados para obtenção dos cortes histológicos para avaliação histométrica. Resultados: Todos os implantes apresentaram-se completamente osseointegrados. No grupo teste foram observados que os níveis ósseos apresentaram-se superiores ao grupo controle. No entanto, a diferença estatisticamente significativa foi encontrada apenas na região vestibular e na região proximal. A dimensão vertical dos tecidos moles foi maior no grupo controle em comparação ao grupo teste. No entanto, foi encontrada diferença estatisticamente significativa apenas na vestibular. Conclusões: O presente estudo demonstrou diferenças nas dimensões dos tecidos duros e moles peri-implantares (vestibular e proximal) como resultado da incompatibilidade do implante / pilar de 0,85 milímetros, quando o ombro do implante foi posicionado ao nível da crista óssea vestibular / Abstract: Aim: to evaluate the effect of platform switching on the peri-implant tissue remodeling. Material & methods: Mandibular premolars and first molars of 6 Labrador dogs were extracted bilaterally. After 3 months of healing, 1 tapered implant was installed on each side of the mandibular molar region with the implant shoulder placed at the level of the alveolar buccal bony crest. On the right side of the mandible, an abutment of reduced diameter in relation to the platform of the implant was used creating a mismatch of 0.85mm (test), while an abutment of the same diameter of the implant platform was affixed in the left side of the mandible (control). The flaps were sutured to allow a non-submerged healing. After 4 months, the animals were sacrificed and ground sections were obtained for histometric assessment. Results: All implants were completely osseointegrated. Bone levels were superior at the test than at the control sites. However, statistically significant differences were found only at the buccal and proximal aspects. The soft tissue vertical dimension was higher at the control compared to the test sites. However, statistically significant differences were demonstrated only or at the buccal aspects. Conclusions: The present study demonstrated differences in peri-implant (buccal and proximal) hard and soft tissue dimensions as a result of an implant/abutment mismatch of 0.85mm, when the implant shoulder was placed at the level of the buccal bony crest / Doutor
328

Distribuição das tensões em próteses protocolo mandibulares com diferentes extensões de cantilever e material de revestimento oclusal /

Medeiros, Rodrigo Antonio de. January 2014 (has links)
Orientador: Marcelo Coelho Goiato / Banca: Daniela Micheline dos Santos / Banca: Marcelo Ferraz Mesquita / Resumo: Neste estudo objetivamos a avaliação da distribuição de tensões na interface osso/implante, por meio do método da fotoelasticidade, em próteses mandibulares tipos protocolos de Branemark, com diferentes extensões de cantilever, materiais de recobrimento estético e uso de intermediários. Foi confeccionado um modelo fotoelástico de uma mandíbula edêntula, contendo cinco implantes 4.0x13 mm hexágono externo (HE) entre os forames mentonianos. Os grupos foram divididos da seguinte forma: Grupo 1 - UCLA e barra metálica; Grupo 2 - UCLA e revestimento oclusal em resina acrílica; Grupo 3 - UCLA e revestimento em cerâmica; Grupo 4 - Intermediário e barra metálica; Grupo 5 - Intermediário e revestimento em resina acrílica; Grupo 6 - Intermediário e revestimento em cerâmica. Com auxílio de uma máquina de ensaio EMIC inicialmente as forças de 70 N foram aplicadas em um ponto anterior, no implante mais posterior e em diferentes extensões de cantilever (até 37,5mm do último implante) na barra metálica e posteriormente nas próteses confeccionadas com barra metálica e revestimento em cerâmica e resina acrílica. Por meio de imagens fotográficas e auxílio do programa Adobe Photoshop CS6 nas imagens obtidas após o teste foi realizada a análise das tensões de acordo com o número de franjas de alta intensidade e de acordo com a concentração e área de distribuição dessas tensões nos grupos testados. Os resultados mostraram um maior número de franjas de alta tensão com o aumento do cantilever, e melhor distribuição das tensões foram para os grupos com as próteses confeccionadas em resina acrílica e para os grupos que continham componente intermediário. Concluímos que o uso de intermediários com próteses protocolo em resina acrílica e a ausência do cantilever tende a apresentar menores números de franjas de alta tensão ao redor dos implantes / Abstract: The aim of this study was to assess the stress distribution, through photoelastic method, on mandibular implant-supported prostheses (Brånemark protocol), associated with different cantilever lengths, aesthetic coating materials and implant abutment. One photoelastic model of an edentulous mandible was made. The model contained five external hexagon implants (HE) with 4.0mm diameters and 13mm lengths placed between the mental foramen. The groups were divided as follows: Group 1 - UCLA and metal bar; Group 2 - UCLA and occlusal acrylic resin coating; Group 3 - UCLA and porcelain coating; Group 4 - Abutment and metal bar; Group 5 - Abutment and acrylic resin coating; Group 6 - Abutment and porcelain coating. A force was applied, using a universal testing machine (EMIC), in different regions - in the most anterior implant, in the most posterior implant and in different cantilever extensions (up to 37.5 mm from the last implant) - in the metal bar and later in the metal bar with porcelain and acrylic resin coated prostheses. The results were obtained through photograph images and the Adobe Photoshop CS6 software was used for qualitative analysis. The analysis was performed according to the number of fringes with high intensity and to the stress distribution area. The results showed a greater number of high stress fringes as the cantilever extension increases. Groups with acrylic resin coating and with abutments exhibited greater stress distribution. We concluded that the use of abutments in acrylic resin protocol prostheses and the absence of the cantilever tends to decrease stress around implants / Mestre
329

Influência de uma superfície modificada por fluoretos na osseointegração de implantes dentais em ratos diabéticos /

Fontanari, Lucas Amaral. January 2013 (has links)
Orientador: José Eduardo Cezar Sampaio / Co-orientador: Elcio Marcantonio Junior / Banca: Humberto Osvaldo Schwartz Filho / Co-orientador: Silvana Regina Perez Orrico / Banca: Ana Emilia Faria Pontes / Banca: Joni Augusto Cirelli / Banca: Eduardo Hochuli Vieira / Resumo: Estudos pré-clínicos e clínicos têm demonstrado que algumas condições sistêmicas como o Diabetes mellitus podem alterar o processo de reparo ósseo. Na cavidade bucal, o diabetes pode estar associado à deficiência na osseointegração e pior prognóstico no tratamento com implantes dentais. Assim, modificações na superfície dos implantes que favoreçam a reparação do tecido ósseo poderiam ajudar a compensar as influências deletérias relacionadas ao diabetes. Este estudo tem por objetivo avaliar, em animais diabéticos, a influência de uma superfície modificada por fluoretos na osseointegração. A amostra consistiu de 180 ratos (90 para teste biomecânico e 90 para histometria) aleatoriamente divididos em três grupos de 60 animais: grupo controle (Grupo C), composto por ratos saudáveis; grupo Diabetes descompensado, composto por animais em que foi realizada indução de Diabetes mellitus (Grupo D); e grupo Diabetes Controlado (Grupo DC) em que o diabetes induzido experimentalmente foi controlado com administração de insulina. O diabetes foi induzido em ratos por injeção de estreptozotocina. Após 4 semanas da indução, cada animal recebeu 2 implantes nas metáfises tibiais proximais, sendo 1 de superfície maquinada (M) e o outro de superfície tratada com fluoretos (F). Os animais foram sacrificados 2, 4 e 6 semanas após a instalação dos implantes. A resistência biomecânica foi avaliada ex-vivo por meio do torque de remoção, e a qualidade do tecido ósseo formado ao redor dos implantes por meio de cortes histológicos não descalcificados, aonde mediu-se a superfície de contato osso/implante (BIC) e a fração de área de tecido ósseo entre as roscas do implante (BAFO). Os dados numéricos (peso, glicemia, torque de remoção, BIC e BAFO) foram avaliados estatisticamente por meio do teste de normalidade de Shapiro-Wilk e pelos testes paramétricos ANOVA complementado pelo... / Abstract: Pre-clinical and clinical studies have been showed that some systemic diseases like the diabetes mellitus may alter the bone repair process. At the oral cavity, the diabetes may be associated with poor osseointegration of dental implants and worsening of the prognosis of dental implants treatment. Thus, modifications on the dental implants surfaces that enhance the bone repair could help to offset the deleterious influences related to diabetes. The aim of this study was to evaluate, in diabetic rats, the influence of different implants surfaces on the osseointegration. A sample of 180 rats (90 for the biomechanical analysis and 90 for the histometric analysis) was randomly allocated in 3 groups of 60 rats each: Control Group (C): Healthy animals; Non-controlled diabetes Group (D): Animals with uncontrolled diabetes; Controlled Diabetes Group (DC): Animals with controlled diabetes. The diabetes was induced by injection of streptozotocin and it was controlled by injectios of insulin. After 4 weeks of the diabetes induction, all the animals received 1 implant in each tibia, one with a machined surface (M) and the other one with a fluoride surface modification. The animals were euthanized 2, 4 and 6 weeks after the implants placement. The biomechanical analysis was performed ex vivo by means of removal torque resistance, and the quality of the bone tissue formed around the implants was assessed by histometric analysis of bone / implant contact (BIC) and bone area between the threads of the implant (BAFO). The numerical data (Weight, Glicemic index, removal torque, BIC, and BAFO) were evaluated by the normality test of Shaprio-Wilk and the one-way Anova complemented by the Tukey's test. All the statistical test were applied with a significance level of 5%. Regarding the biomechanical analysis, for the machined surface implants, the group D showed lower removal torque values (p <0.05) than the group C... / Doutor
330

Efeito da altura do pilar de diferentes cimentos e das ciclagens térmica e mecânica sobre a resistência máxima á tração de infraestruturas metálicas cimentadas /

Alfenas, Bruna Fernandes Moreira. January 2013 (has links)
Orientador: José Mauricio dos Santos Nunes Reis / Banca: João Neudenir Arioli Filho / Banca: Marcelo Ferraz Mesquita / Resumo: Este estudo avaliou (1) o efeito da altura do pilar, dos diferentes cimentos e da termociclagem e (2) o efeito dos diferentes cimentos e da ciclagem mecânica sobre a resistência máxima à tração (RMT) de restaurações implantossuportadas cimentadas. Pilares de titânio (UCLA), com alturas de 4,0 e 6,0 mm (1), ou 4,0 mm (2), foram torqueados com 32 N.cm a análogos de implantes HI. Infraestruturas em Co-Cr, jateadas com óxido de alumínio 50 μm foram cimentadas com: Fosfato de Zinco- FZ; RelyX Luting 2- RXL2; C & B Cement- C&B; RelyX U100- RXU100 e RelyX Temp NE- RXTNE. Os conjuntos foram submetidos aos ensaios de tração (0,5 mm/min) após: 1- armazenagem em saliva artificial a 37 ºC durante 24 h (controle), 2- termociclagem (10.000 ciclos, 5,0 e 55 °C, 30 s de imersão), ou 3- ciclagem mecânica (106 ciclos, 140 N, 15 Hz). Os dados foram analisados por (1) 3- way ANOVA e Dunnett, e (2) 2-way ANOVA e Tukey HSD (α=0,05). Independentemente da altura do pilar, não houve diferença nos resultados dos grupos sem termociclagem (p≥0,05). Após termociclagem, houve aumento (p<0,05) na RMT nos pilares de 6,0 mm. Após ciclagem mecânica, houve diminuição (p<0,05) nos resultados de RMT produzidos por RXL2. A altura do pilar influenciou os resultados do RXL2, que produziu RMT mais elevada com os pilares de 6,0 mm. Com exceção do RXL2, a ciclagem mecânica não comprometeu a RMT das infraestruturas cimentadas. Em determinadas condições, o RXTNE produziu RMT semelhante à alguns cimentos finais. / Abstract: This study evaluate (1) the effect of abutment height, different cements and thermocycling, and (2) the effect of different cements and cyclic loading on the ultimate tensile strength (UTS) of cement-retained/implant-supported cast restorations. UCLA-type abutments with 4.0 and 6.0-mm height (1), or 4.0-mm height (2) were torqued to with 32 N.cm to internal hexagon dental implant replicas. Copings casted in Co-Cr, sandblasted with 50-μm aluminum oxide particles were cemented with: Zinc Phosphate- ZP; RelyX Luting 2- RXL2; C & B Cement- C&B; RelyX U100- RXU100 and RelyX Temp NE- RXTNE. The assemblies were submitted to the tensile test (0.5 mm/min) after: 1- storage in artificial saliva at 37 °C for 24 h (control), 2- thermocycling (10,000 cycles, 5.0 and 55 ºC, 30-s dwell time), or 3- cyclic loading (106 cycles, 140 N, 15 Hz). Data were analyzed by (1) 3-way ANOVA and Dunnett tests, and (2) 2-way ANOVA and Tukey HSD tests (α=0.05). Regardless of the abutments' heights, no significant differences were found among the UTS of the nonthermocycled groups (p≥0.05). After thermocycling, an increasing in the UTS was observed for the 6.0-mm abutments (p<0.05). After cyclic loading, the UTS values produced by RXL2 were decreased (p<0.05). The abutment's heights used affected the RXL2 results, which produced higher results with the 6.0-mm abutments. With the exception of RXL2, cyclic loading did not detrimentally affect the UTS of the cemented castings. In some conditions, the provisional cement RXTNE produced similar UTS to some definitive cements. / Mestre

Page generated in 0.0491 seconds