• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 340
  • 11
  • 11
  • 11
  • 11
  • 8
  • 4
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 348
  • 125
  • 118
  • 93
  • 89
  • 47
  • 43
  • 42
  • 41
  • 40
  • 39
  • 38
  • 37
  • 33
  • 33
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
151

Resistência à infiltração de glicose de quatro cimentos reparadores / Glucose leakage resistance of four repair cements

Fernanda de Souza Leal Fonseca 26 January 2010 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente estudo teve como objetivo comparar a qualidade do selamento promovido por 3 cimentos reparadores endodônticos: Ceramicrete, iRoot-BP Plus e BioAggregate, com o ProRoot MTA branco, utilizando o modelo de infiltração de glicose sob pressão. 64 incisivos centrais superiores, recém-extraídos e sem tratamento endodôntico foram selecionados. A instrumentação do canal radicular foi realizada em todos os dentes com brocas Gates-Glidden e limas K-Flexofile (Dentsply Maillefer, Ballaigues Suíça), 1mm aquém do ápice. A patência foraminal foi confirmada a cada instrumento usado. Os dentes tiveram suas coroas removidas padronizando-os em 15mm de comprimento. Foi realizada apicetomia a 3mm do ápice e o preparo da cavidade retrógrada com o auxílio do ultrassom Various 350 (NSKNakanishi Inc., Tóquio, Japão) e da ponta E32D (NSKNakanishi Inc., Tóquio, Japão). As raízes foram distribuídas, randomicamente, em quatro grupos experimentais (n=15): G1Ceramicrete, G2iRoot BP Plus, G3BioAggregate e G4ProRoot MTA branco. Como controle negativo (n=2) foram utilizados dentes hígidos, e como controle positivo (n=2), dentes acessados e com patência confirmada. Os cimentos reparadores foram manipulados seguindo as recomendações do fabricante e inseridos na cavidade retrógrada utilizando a mesma ponta ultrassônica usada no preparo. As amostras foram mantidas na presença de umidade por 72h para o completo endurecimento dos materiais. As raízes foram montadas em um dispositivo de dupla-câmara selada para a infiltração da glicose. Foram utilizados 0,75ml de solução de glicose a 1Mol/L na câmara superior e 0,75ml de água destilada na câmara inferior. Os dispositivos foram conectados a um sistema de distribuição de pressão, que permitiu a infiltração de 32 amostras em uma mesma etapa. A solução de glicose foi forçada apicalmente sob uma pressão de 15psi durante 1 hora. Uma alíquota de 10l foi coletada da câmara inferior para quantificar a glicose infiltrada. A concentração de glicose foi determinada com o auxílio do Kit GlucoseHK (Megazyme, Wicklow, Irlanda) e de um espectrofotômetro de luz visível (Campsec M330, Cambridge, Reino Unido) em um comprimento de onda de 340nm. O teste não-paramétrico Kruskal-Wallis e o teste Dunns foram utilizados na análise estatística. Os resultados encontrados demonstraram que houve diferença significativa entre os grupos experimentais (p=0,0036). O BioAggregate apresentou a maior concentração de glicose-1,85(g/L), seguido do ProRoot MTA-1,2; IRoot BP-0,85 e Ceramicrete-0,75. Não houve diferença entre os três novos cimentos reparadores e o material padrão-ouro (p>0,05). Não houve diferença entre Ceramicrete e iRoot BP Plus (p>0,05), porém estes foram estatisticamente diferentes do BioAggregate (p<0,05). Diante dos resultados obtidos, pode-se concluir que: nenhum dos cimentos testados foi capaz de promover selamento hermético; os três novos cimentos testados não revelaram o mesmo padrão de selamento; os três novos cimentos testados revelaram um padrão de selamento semelhante a do ProRoot MTA branco; e o Ceramicrete e o iRoot BP Plus apresentaram padrão de selamento superior em comparação com o BioAggregate. / The present study sought to compare the sealing ability of three new reparative endodontic cements Ceramicrete, iRoot-BP Plus, BioAggregate and compared to white ProRoot MTA, using the glucose leakage model under pressure. Sixty-four recently extracted maxillary incisors, without previous endodontic treatment, were selected. A crown-down root canal instrumentation was performed using Gates-Glidden burns and Kerr Flexofile (Dentsply Maillefer, Ballaigues Switzerland), 1mm short of the apical foramen (working length). The apical patency was confirmed after the use of each instrument, with a Kerr file #10, 1mm beyond the foramen. The teeth had their crowns removed, leaving roots 15mm in length. After that, apicetomy was carried out at 3mm from the apex. The retrograde preparation was performed using the E32D ultrasonic tip (NSK Nakanishi Inc., Tokyo, Japan). Roots were randomly distributed in four experimental groups (n=15): G1 - Ceramicrete, G2 - iRoot BP Plus, G3 - BioAggregate and G4 - white ProRoot MTA as gold-standard for comparisons. For the negative control group (n=2) teeth with intact crowns were used, and for the positive control (n=2), teeth with access and apical patency. The root-end filling material was manipulated as recommended by the manufacturer and inserted into the retrograde cavity using the same ultrasonic tip. The samples were stored at 100% humidity for three days to allow setting of the material. After that, the roots were mounted in a double-chamber apparatus where 0,75ml of 1Mol/L glucose solution was placed into the superior chamber and 0,75ml of distilled water was placed into the inferior chamber. The devices were connected to a pressure distribution system that was developed to allow the leakage of 32 samples at a single stage. The glucose solution was forced apically under a pressure of 15psi during 1 hour. A sample of 10l was taken from the inferior chamber and the glucose concentration was measured following an enzymatic reaction using the Glucose HK Kit (Megazyme, Wicklow, Ireland) and a spectrophotometer (Campsec M 330, Cambridge, UK) at a wave-length of 340nm. The Kruskal-Wallis and the Dunns test were used for statistical analyses. The results demonstrated that there was significant difference between experimental groups (p=0,0036). BioAggregate displayed the highest glucose concentration - 1.85(g/L), followed by ProRoot MTA - 1.2; iRoot BP Plus - 0.85; Ceramicrete - 0.75. No significant difference was observed between the three new reparative cements and the gold-standard (p>0.05). There was no difference between Ceramicrete and iRoot BP Plus (p>0.05), however both materials were significantly different fromBioAggregate (p<0.05). Considering the results, it can be concluded that none of the tested cements was able to prevent glucose leakage, the 3 new tested cements do not presented a similar quality of sealing, and the three new tested cements presented a similar sealing pattern of ProRoot MTA and both Ceramicrete and iRoot BP Plus presented better quality of sealing than BioAggregate.
152

Efeito da bioinspiração e infiltração de zircônia por sílica nas propriedades mecânicas de bicamadas cerâmicas / The effect of bioinspiration and zirconia infiltration with silica on mechanical properties of bilayered ceramics

Toyama, Dominique Yukie [UNESP] 30 January 2017 (has links)
Submitted by Dominique Yukie Toyama null (dominique.toyama@gmail.com) on 2017-03-05T17:10:56Z No. of bitstreams: 1 Dissertação Dominique Toyama v2.pdf: 2694471 bytes, checksum: 46622aaa3d27a2c4661becae14cbed29 (MD5) / Rejected by Juliano Benedito Ferreira (julianoferreira@reitoria.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo: No campo “Versão a ser disponibilizada online imediatamente” foi informado que seria disponibilizado o texto completo porém no campo “Data para a disponibilização do texto completo” foi informado que o texto completo deverá ser disponibilizado apenas 6 meses após a defesa. Caso opte pela disponibilização do texto completo apenas 6 meses após a defesa selecione no campo “Versão a ser disponibilizada online imediatamente” a opção “Texto parcial”. Esta opção é utilizada caso você tenha planos de publicar seu trabalho em periódicos científicos ou em formato de livro, por exemplo e fará com que apenas as páginas pré-textuais, introdução, considerações e referências sejam disponibilizadas. Se optar por disponibilizar o texto completo de seu trabalho imediatamente selecione no campo “Data para a disponibilização do texto completo” a opção “Não se aplica (texto completo)”. Isso fará com que seu trabalho seja disponibilizado na íntegra no Repositório Institucional UNESP. Por favor, corrija esta informação realizando uma nova submissão. Agradecemos a compreensão. on 2017-03-09T14:01:43Z (GMT) / Submitted by Dominique Yukie Toyama null (dominique.toyama@gmail.com) on 2017-03-10T18:49:30Z No. of bitstreams: 1 Repositório.pdf: 9462693 bytes, checksum: b3c5b554b9ad7e33181206e7a901f8e6 (MD5) / Approved for entry into archive by LUIZA DE MENEZES ROMANETTO (luizamenezes@reitoria.unesp.br) on 2017-03-16T19:50:08Z (GMT) No. of bitstreams: 1 toyama_dy_me_sjc.pdf: 9462693 bytes, checksum: b3c5b554b9ad7e33181206e7a901f8e6 (MD5) / Made available in DSpace on 2017-03-16T19:50:08Z (GMT). No. of bitstreams: 1 toyama_dy_me_sjc.pdf: 9462693 bytes, checksum: b3c5b554b9ad7e33181206e7a901f8e6 (MD5) Previous issue date: 2017-01-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Neste trabalho avaliou-se o comportamento mecânico e a homogeneidade estrutural de bilaminados cerâmicos com configuração convencional (compressão da zircônia) e bioinspirada (tração da zircônia) com e sem infiltração de sílica. Além disso, determinou-se a distribuição de tensões utilizando a análise de elementos finitos, e avaliou-se o modo de falha e o mecanismo de adesão da interface porcelana/zircônia. Amostras bilaminadas foram confeccionadas com Y-TZP e cerâmica injetável e divididos em 4 grupos (n=30): zircônia sob compressão (T), zircônia infiltrada sob compressão (I), zircônia sob tração (B) e zircônia infiltrada sob tração (BI); para teste da resistência à flexão biaxial. A infiltração por sílica ocorreu pelo método sol-gel. Os dados (MPa) do ensaio mecânico foram avaliados com análise de Weibull (IC 95 %). Análise de elementos finitos utilizou o critério de tensão máxima principal para avaliar a distribuição de tensões nos modelos e seus resultados foram apresentados em forma de figuras e gráficos da tensão máxima principal (TMP). A camada de infiltração foi caracterizada usando DRX e microscopia (MEV, MEV-FEG e EDS). O comportamento da interface foi analisado usando resistência ao risco e dureza. O grupo mais homogêneo estruturalmente foi o BI (m= 9,59). A concentração de tensão na cerâmica feldspática foi menor nos grupos bioinspirados. Houve formação de silicato de zircônia na superfície dos discos de zircônia infiltrados e preenchimento de defeitos superficiais e internos. A zircônia tradicional teve desempenho melhor do que a zircônia infiltrada no teste de resistência ao risco. A endentação interfacial mostrou que o elo mais fraco do conjunto é a cerâmica feldspática. Conclui-se que para melhorar o desempenho de bilaminados é preciso melhorar o material de recobrimento e não a adesão entre os materiais. / This study analyzed the mechanical behavior of bilayers using conventional arrangement (leucite ceramic under traction) and a bioinspired arrangement (zirconia under traction) with or without sol-gel silica infiltration, analyze stress distribution using FEA, characterize infiltration layer and observe interfacial behavior. 120 bilayered specimens were produced for biaxial flexural strength testing using Y-TZP and pressed ceramic and divided into 4 groups (n=30): zirconia under compression (T), infiltrated zirconia under compression (I), zirconia under traction (B) and infiltrated zirconia under traction (BI). The zirconia was infiltrated using sol-gel method. The results for the biaxial flexural strength (MPa) were analyzed using Weibull analysis (CI 95 %). Stress distribution within the models were examined using maximum principal stress and the results were presented as graphs and figures. The infiltration layer was characterized using XRD and microscopy (SEM, FEG-SEM and EDS). The interfacial behavior was analyzed using scratch test and micro-hardness indentation. The BI group was the most reliable (m=9.59). The stress distribution in the feldspar ceramic was better for the bioinspired groups. The infiltrated zirconia discs presented zirconia silicate formation on the surface and plugged internal flaws. The traditional zirconia had a better scratch performance compared to the infiltrated zirconia. The interfacial indentation showed that the weakest link of the set is the feldspar ceramic. To improve the performance of bilayers, a better coverage material is needed rather than an improvement in adhesion.
153

Análise morfológica de cones de guta-percha submetidos a diferentes tratamentos de desinfecção e sua influência na microinfiltração /

Rosa, Patrícia Campos Ferreira da. January 2011 (has links)
Orientador: Simone Helena Gonçalves de Oliveira / Banca: Carlos Henrique Ribeiro Camargo / Banca: Brenda Paula Figueiredo de Almeida Gomes / Resumo: Os cones de guta-percha precisam passar por um processo de desinfecção química rápida antes da obturação. Algumas soluções são capazes de agir em 1 minuto, mas se este período de imersão for prolongado, alterações podem ser causadas na estandardização dos cones, dificultando a adaptação ao canal radicular. Essa pesquisa avaliou as alterações morfológicas, em microscopia eletrônica de varredura (MEV), que ocorrem na superfície dos cones de guta-percha em períodos excedidos aos preconizados. Clorexidina 2% (CLX), hipoclorito de sódio 2,5% (NaOCL), ácido peracético 2% (AP) e solução de ácido peracético 0,25% (SAP) foram as soluções utilizadas nos períodos de 1 minuto, 30 minutos, 6 horas e 12 horas. Os grupos foram divididos de acordo com a solução e período de desinfecção (n=12). Os resultados indicaram que houve diferença estatística significante entre as soluções e períodos testados. Em 1 minuto, todas as soluções não diferiram do controle. Após 30 minutos, a SAP alterou significativamente a morfologia dos cones. O teste de espectrometria de energia dispersiva (EDS) indicou que todas as substâncias e períodos alteram a composição química dos cones de gutapercha. A relação da desinfecção na microinfiltração da obturação também foi avaliada nos grupos que sofreram desinfecção por 12 horas. O grupo da SAP apresentou diferença estatística significante em relação ao controle, pois 100% das suas raízes apresentaram infiltração. Os demais grupos da CLX, NaOCL e AP, embora sem diferença estatística significante, tiveram respectivamente 9, 8 e 8 do total de 12 das suas raízes com infiltração. Conclui-se que o processo de desinfecção pode causar alterações morfológicas se o período de imersão for excedido e que, além de alterarem a composição química dos cones de guta-percha, estas soluções podem influenciar no selamento da obturação / Abstract: The gutta-percha points must go through a fast chemical disinfection process before obturation. Some solutions are able to work in 1 minute, but if this immersion period is prolonged, changes can be caused on the points standardization, hampering the adaptation to root canal. This study evaluated the morphological changes, in scanning electron microscopy (SEM), which occur on the surface of gutta-percha points in periods beyond the recommended. 2% chlorhexidine (CLX), 2.5% sodium hypochlorite (NaOCl), 2% peracetic acid (PA) and peracetic acid solution 0.25% (PAS) were used for 1 minute, 30 minutes, 6 hours and 12 hours. The groups were divided according to disinfecting solution and period (n = 12). The results indicated a statistically significant difference between the solutions and periods tested. In one minute, none of the solutions differed from control. After 30 minutes, PAS has significantly changed the morphology of the points. The energy dispersive x-ray test (EDS) showed that all substances and periods, alter the chemical composition of the gutta-percha points. The ratio of the disinfection on microleakage of the filling was also evaluated. The SAP 12 hours group had a statistically significant difference compared to the control and the other groups, since 100% of their roots showed infiltration. Groups of 12 hours period of CHX, NaOCl and PA, although without significant difference, had respectively 9, 8 and 8 out of 12 of its roots with infiltration. It is concluded that the disinfection process can cause morphological changes if the immersion period is exceeded and that, besides altering the chemical composition of gutta-percha points, these solutions can influence on the hermetic sealing of the root canal / Mestre
154

Material obturador de canal radicular à base de uretano metacrilato : estudo histológico e da infiltração coronária em dentes de cães /

Avendaño Rueda, Julio César. January 2006 (has links)
Orientador: Léa Assed Bezerra da Silva / Resumo: O objetivo deste estudo foi o de avaliar a biocompatibilidade e a infiltração no sentido coroa/ápice de um cimento obturador de canais radiculares à base de uretano dimetacrilato denominado Endo-Rez. Foram utilizados 56 canais radiculares de dentes de cães, os quais foram divididos em 4 grupos experimentais: Grupo I, Endo-Rez com restauração coronária (18 raízes); Grupo II, Sealapex com restauração coronária (10 raízes); Grupo III, Endo-Rez sem restauração coronária (18 raízes) e Grupo IV, canais radiculares obturados com Sealapex sem restauração coronária (10 raízes). Os canais radiculares foram instrumentados pela técnica clássica e obturados pela técnica de condensação lateral ativa (Grupo II e IV) e técnica de cone único (Grupo I e III). Decorridos 90 dias, os animais foram mortos e as peças submetidas ao processamento histológico. A avaliação histopatológica mostrou que os grupos I e III que foram obturados com Endo-Rez com e sem restauração coronária respectivamente, apresentaram semelhante infiltrado inflamatório periapical crônico de grau moderado/severo, severo aumento do espaço periodontal apical e ausência de selamento biológico apical. O grupo IV, obturado com Sealapex, aberto ao meio bucal por 90 dias, apresentou características histopatológicas similares aos grupos I e III. O Grupo II, cujos canais radiculares foram obturados com o Sealapex com restauração coronária ocorreu infiltrado inflamatório moderado e espessamento do espaço periodontal apical predominantemente leve, na maioria dos espécimes, exibindo selamento apical biológico em apenas 1 caso, portanto 10% dos espécimes. / Abstract: The aim of this study was to evaluate in vivo the biocompatibility and coronal leakage of a new urethane metacrylate resin-based sealer, EndoRez. Sixty root canals of dog's teeth were divided into four experimental groups. Group I and III, EndoRez with and without coronal obturation respectively, Group II and IV Sealapex with and without coronal obturation respectively. The teeth were instrumented with a classic technique with Groups II and IV filled by the lateral condensation active technique with gutta percha points, while groups I and III were filled by the single cone technique. After 90 days, the animals were killed and specimens prepared histopathologically. The histopathological evaluation showed in the Groups I and III filled with EndoRez and the Group IV filled with Sealapex, most specimens with severe and moderate chronic inflammatory infiltrate, severe thickness of periodontal ligament and the apical sealing absence, Whereas, in Group II filled with Sealapex, most specimens showed mild and moderate inflammatory infiltrate, less thickness of periodontal ligament, and 30% exhibit biological apical sealing. / Mestre
155

Infiltração marginal em cavidades de classe V. Efeito de sistema adesivo e preparo cavitário /

Araújo, Taylane Soffener Berlanga de. January 2005 (has links)
Orientador: Maria Salete Machado Cândido / Banca: Edson Alves de Campos / Banca: Luís Alberto Plácido Penna / Banca: José Roberto Cury Saad / Banca: Marcelo Ferrarezi de Andrade / Resumo: Este estudo teve por objetivo analisar in vitro a influência de dois sistemas adesivos resinosos, sendo um autocondicionante de dois passos (Clearfil SE Bond 2) e um convencional também de dois passos (Master Bond), bem como o tratamento das margens cavitárias no controle da microinfiltração marginal. Preparos cavitários de classe V foram executados na face vestibular em 80 dentes anteriores bovinos previamente extraídos, divididos em oito grupos (n=10). O grau de infiltração marginal foi avaliado por penetração do agente traçador (Nitrato de Prata (AgNO3) a 50%) nas paredes incisal e cervical por meio de um "Software-Image Tool", no qual se mede o grau de infiltração em micrômetros e, portanto, análise quantitativa, os resultados submetidos à Análise de Variância seguida do teste de Tukey para observação das diferenças, concluindo-se que: a) os sistemas adesivos apresentaram estatisticamente o mesmo comportamento; b) existe diferença estatisticamente significante entre as técnicas de preparos utilizados sendo que os preparos realizados nos Grupo I e Grupo II, bem como nos Grupos VII e VIII, apresentaram comportamento semelhante e os melhores resultados para redução da microinfiltração; c) os preparos do Grupo III e Grupo IV apresentaram maiores índices de microinfiltração marginal, no entanto, semelhantes aos Grupos V e VI; d) a região cervical apresentou maior nível de microinfiltração quando comparada com a região incisal. / Abstract: This study aimed to analyse in vitro the influence of two resinous adhesive systems: one self-etching of two steps (Clearfil SE Bond 2) and one also conventional of two steps (Master Bond), as well as the treatment of the cavity margins in the marginal microleakage control. Cavity preparations of class V were carried out on the buccal surface of 80 bovine anterior teeth, previously extracted, divided into eight groups (n=10). The marginal leakage degree was evaluated by the penetration of the tracer agent (Silver Nitrate (AgNO3) at 50%); on the incisor and cervical walls through a Software-Image Tool that measures the leakage degree in micrometers and, therefore, quantitative analysis, which results were subjected to the Variance Analysis and afterwards to the Tukey's test in order to observe the differences it was possible to conclude that: a) the adhesive systems presented statistically the same behaviour; b) there is a statistically meaningful difference between the preparation techniques that were used and the preparations that were carried out in Group I and Group II, as well as Groups VII and VIII, that presented similar behaviour and the best results for the reduction of microleakage; c) the preparations of Group III and Group IV presented higher rates of marginal microleakage, however, they were similar to Groups V and VI; d) the cervical region presented higher level of microleakage comparing to the incisor region. / Doutor
156

Fatores reguladores da angiogênese e infiltração tumoral nos carcinomas mamários positivos para a citoqueratina 5 / Regulating factors of angiogênese and tumoral infiltration in positive the mammary carcinomas for citoqueratina 5

Fabiana Ribeiro do Vale 01 September 2006 (has links)
O reconhecimento de subtipos de carcinomas mamários baseados em suas características moleculares trouxe novas perspectivas na investigação do câncer de mama. Algumas proteínas chaves reguladoras da angiogênese e da infiltração tumoral foram avaliadas em carcinomas de mama de fenótipo basal (CK5+). Foi realizado estudo Imunoistoquímico com 14 anticorpos primários em 100 casos de carcinoma ductal. A positividade para citoqueratina 5 correlacionou-se com indicadores de mau prognóstico, incluindo idade precoce, alto grau histológico, linfonodos positivos, estádio patológico avançado, negatividade para receptores hormonais, e uma alta taxa de proliferação celular, avaliado pelo Ki67. A positividade para a CK5 também se correlacionou com a expressão do VEGF, mas não com a densidade da microvascularização. Considerando que a superexpressão de VEGF pelas células neoplásicas da mama leva a um aumento da atividade proliferativa in vitro independente de seu efeito angiogênico, a expressão diferencial do VEFG pode contribuir para o comportamento mais agressivo da neoplasia. Houve correlação do CK5 com TIMP1, mas não com MMP1, MMP2, EMMPRIN, TIMP2 and PAI, indicando que o estimulo antiproteolítico pode ser preponderante nesta neoplasia. / The recognition of subtypes of breast carcinomas based on their molecular features has brought new perspectives in breast cancer investigation. Some key regulators of angiogenesis and tumor infiltration were evaluated in breast carcinomas of basal-phenotype (CK5+). Immunohistochemistry with 14 primary antibodies was performed in 100 formalin-fixed paraffin-embedded samples of invasive ductal carcinomas. Cytokeratin 5 correlated with indicators of poor outcome, including precocious age, high histological grade, lymph node positivity, advanced pathological stage, negativity for hormonal receptors, and a high proliferative rate (Ki67 labeled index). CK5 also correlated with VEGF expression but not with the microvessel density. Considering that VEGF overexpressing neoplastic mammary cells display increased proliferative activity in vitro regardless its angiogenic effect, the differential expression of VEGF may contribute for the more aggressive behavior of these neoplasms. CK5 correlated with TIMP1, but not MMP1, MMP2, EMMPRIN, TIMP2 and PAI, indicating that anti-proteolytic stimuli may be preponderant in these neoplasms.
157

"Comparação dos períodos de latência e duração da lidocaina 2% associada a adrenalina 1:100.000 e da articaína 4% associada a adrenalina 1:200.000 e 1:100.000 na infiltração maxilar" / Comparison of onset and duration periods of 2% lidocaine associated with 1:100.000 adrenalin and of 4% articaine associated with 1:200.000 and 1:100.000 adrenalin on maxilar infiltration"

Carina Gisele Costa 04 July 2003 (has links)
RESUMO Comparou-se os períodos de latência e duração da lidocaína 2% associada à adrenalina 1:100.000 (Lidocaína 100 ® da DFL), e da articaína 4% associada à adrenalina 1:200.000 (Septanest 1:200.000 ® da Septodont) e 1:100.000 (Septanest 1:100.000 ® da Septodont), na polpa dentária e gengiva vestibular, em anestesias locais infiltrativas maxilares. Vinte pacientes voluntários, saudáveis, de ambos os sexos, entre 18 e 50 anos de idade receberam tratamento restaurador de baixa complexidade ou selamento de cicatrículas e fissuras nas superfícies oclusais de três dentes superiores posteriores de uma mesma hemiarcada. Cada paciente recebeu, aleatoriamente, um tubete (1,8 ml) de cada solução anestésica local em três consultas. Os períodos de latência e duração da anestesia local na polpa dentária foram monitorados com um aparelho estimulador pulpar elétrico (Vitality Scanner Model 2005 ® da Analytic Endodontics) e na gengiva vestibular por meio do estímulo com a ponta de um explorador. Através do Teste de Kruskal-Wallis foram detectadas diferenças estatisticamente significantes ao nível de 5% entre lidocaína 2% associada à adrenalina 1:100.000, quando comparada tanto com a articaína 4% associada à adrenalina 1:200.000 quanto com a articaína 4% associada à adrenalina 1:100.000, para as variáveis: período de latência e duração na polpa dentária e período de duração na gengiva, sendo que a lidocaína 2% associada à adrenalina 1:100.000 apresentou a maior média para o período de latência pulpar e as menores médias para os períodos de duração na polpa dentária e na gengiva (respectivamente, 2,8, 39,2 e 42,2 minutos),quando comparada à articaína 4% associada à adrenalina 1:200.000 (respectivamente, 1,6, 56,7 e 55,3 minutos) e 1:100.000 (respectivamente, 1,4, 66,3 e 64,7 minutos). Houve diferença estatisticamente significante entre as duas soluções de articaína apenas para o período de duração na gengiva, cuja maior média foi a da articaína 4% associada à adrenalina 1:100.000. Não houve diferença estatisticamente significante entre os grupos para o período de latência gengival. Conclui-se que as soluções de articaína apresentam latência mais curta e duração mais longa do que a solução de lidocaína quando da anestesia pulpar. Para a latência gengival não há diferença entre as três soluções testadas, porém, para a duração gengival, a solução de articaína 4% associada à adrenalina 1:100.000 apresenta a maior duração. / SUMMARY Local anesthesias by maxillar infiltration with 2% lidocaine associated with 1:100.000 adrenalin (Lidocaina 100 ® by DFL), 4% articaine associated with 1:200.000 (Septanest 1:200.000 ® by Septodont) and 1:100.000 adrenalin (Septanest 1:100.000 ® by Septodont) were compared concerning to their onset and duration on dental pulp and gingiva. Twenty healthy volunteer patients, of both gender, between 18 and 50 years of age, received filling treatment of low complexity or fissure sealing on the occlusal surface of three superior posterior teeth of the same side. Each patient randomly received an ampoule (1,8ml) of each local anesthetic solution on three appointments. The onset and duration periods of local anesthesia on dental pulp were monitored with an electric pulptester (Vitality Scanner Model 2005 ® by Analytic Endodontics) and on buccal gingiva by the stimulus performed with the point of a probe. Kruskall-Wallis test identified statistic significant difference by the level of 5% between 2% lidocaine associated with 1:100.000 adrenalin when compared with both 4% articaine associated with 1:200.000 or 1:100.000 adrenalin for the following variants: onset and duration periods on dental pulp and duration period on gingiva. 2% lidocaine associated with 1:100.000 adrenalin presented the longest average for onset period on dental pulp and the minorest averages for duration periods on dental pulp and gingiva (respectively, 2,8, 39,2 and 42,2 minutes), when compared with 4% articaine associated with 1:200.000 (respectively, 1,6, 56,7 and 55,3 minutes) and 1:100.000 adrenalin (respectively, 1,4, 66,3 and 64,7 minutes). There was statistic significant difference between the two articaine solutions just for duration period on gingiva, whose longest average was that of 4% articaine associated with 1:100.000 adrenalin. There was no statistic significant difference between the groups for onset period on gingiva. It can be concluded that both articaine solutions present faster onset and longer duration than the lidocaine solution on pulpal anesthesia. For gingival onset there is no difference between the three tested solutions, however, for gingival duration, 4% articaine associated with 1:100.000 adrenalin presents the longest duration.
158

Estudo da condutividade hidráulica e do potencial de lixiviação de fósforo em colunas de solo compactado

Chimbida, Janete Terezinha 29 May 2006 (has links)
Made available in DSpace on 2017-07-10T19:24:40Z (GMT). No. of bitstreams: 1 Janete Terezinha Chimbida.pdf: 933108 bytes, checksum: 8674521518101715064fb24da02f65dd (MD5) Previous issue date: 2006-05-29 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / To present research it was developed in the Universidade Estadual do Oeste do Paraná -UNIOESTE, using the Laboratório de Geotecnia for assembly of the experiment and the Laboratório de Saneamento for chemical analyses. The coming of the processes liquid and solid residues and activities agro industries have as characteristic common to high nutrients load, above all Nitrogen and Phosphorous. When these materials are disposed in a of wastes contention system without correct impermeabilization it can happen the contamination of the groundwater. The objective of this work is to verify the quality of typical distroferric Red Oxisol, of wide regional occurrence, compacted in what it says respect to the permeability; the lixiviation potential of the phosphate; accumulation of the phosphate in the soil and the alterations happened in the soil matrix after the percolation of the swine effluent. The experiment was driven in laboratory scale, being set up a total of 27 columns of PVC tubes, of 1,15m of length and 0,10m of diameter, being in the compacted base 0,03m of soil in three moisture contents (28, 32 and 36%) and applied gross swine effluent (E1), diluted swine effluent (E2) and distilled water (E3), making three repetitions, percolating for at the most 15 days or 8 times the total volume of pores (VP), picking up samples of 25 mL, evaluating the pH, CE and phosphate. Then the columns were dismounted, removing the hydraulic load and dividing the soil in three increments: 0 to -1 cm, -1 at -2 cm and -2 to -3 cm. Discarded the middle increment. It was conduced the analysis of the content organic matter (MO), total and uptake of phosphorous, it was also determined the pH, the zero point charge (ZPC) and the surface potential. The results showed reduction in the permeability with the application of swine effluent to at levels that indicate a possible colmatation; the measures of electric conductivity (CE) were smaller than the initials in the effluents, and the retention of particles was shown with an decrease in the soil surface potential; as the percolation of the phosphate, it was minimum and it happened in the treatments with the soil was not appropriately compacted. The soil analysis showed that the phosphate was retained in the superior increment. / A presente pesquisa foi desenvolvida na Universidade Estadual do Oeste do Paraná UNIOESTE Campus de Cascavel, utilizando o Laboratório de Geotecnia para a montagem do experimento e o Laboratório de Saneamento para a realização das análises químicas. Os resíduos líquidos e sólidos provenientes dos processos e atividades agroindustriais têm como característica comum a alta carga de nutrientes, sobretudo Nitrogênio e Fósforo. Quando esses materiais são dispostos em um sistema de contenção de rejeitos, sem a correta impermeabilização, pode ocorrer a contaminação das águas subterrâneas. O objetivo deste trabalho foi verificar a qualidade do Latossolo Vermelho distroférrico típico, de larga ocorrência regional, compactado, em relação à permeabilidade; ao potencial de lixiviação do fosfato; à acumulação do fosfato no solo e às alterações ocorridas na matriz do solo, após a percolação do efluente de suíno. O experimento foi conduzido em escala de laboratório, montando-se um total de 27 colunas de tubos de PVC, de 1,15 m de comprimento e 0,10 m de diâmetro, compactado na base 0,03 m de solo em três teores de umidade (28, 32 e 36%) e aplicado efluente de suíno bruto (E1), efluente de suíno diluído (E2) e água destilada (E3), com três repetições. Deixou-se percolar por no máximo 15 dias ou 8 vezes o volume total de poros (VP), recolhendo-se amostras de 25 mL, para avaliação do pH, da condutividade elétrica (CE) e da concentração de fosfato. Em seguida, as colunas foram desmontadas, removendo-se a carga hidráulica e dividindo-se o solo em três incrementos: 0 a 1 cm, -1 a 2 cm e 2 a 3 cm. Nos incrementos superior e inferior, realizou-se a análise do teor de matéria orgânica (MO), fósforo total e fósforo assimilável e determinou-se o pH, o ponto de carga zero (PCZ) e o potencial elétrico de superfície, sendo que o incremento do meio foi descartado. Os resultados mostraram redução na permeabilidade com a aplicação de efluente de suíno a níveis que indicam uma possível colmatação; as medidas de condutividade elétrica (CE) foram menores que as iniciais nos efluentes. Verificou-se a retenção de partículas com um decréscimo no potencial de superfície no solo; quanto à percolação do fosfato, foi mínima e ocorreu nos tratamentos em que o solo não foi compactado adequadamente. A análise de solo mostrou que o fosfato ficou retido no incremento superior.
159

Estudo artrográfico sobre a comunicação entre as articulações társicas em cavalos da raça crioula

Gehm, Marcelo Varaschin 11 August 2015 (has links)
Submitted by Marcos Anselmo (marcos.anselmo@unipampa.edu.br) on 2016-09-09T20:32:46Z No. of bitstreams: 2 MARCELO VARASCHIN GEHM.pdf: 579818 bytes, checksum: ab3693a439153cd17184df2fc888ec66 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Approved for entry into archive by Marcos Anselmo (marcos.anselmo@unipampa.edu.br) on 2016-09-09T20:33:05Z (GMT) No. of bitstreams: 2 MARCELO VARASCHIN GEHM.pdf: 579818 bytes, checksum: ab3693a439153cd17184df2fc888ec66 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) / Made available in DSpace on 2016-09-09T20:33:05Z (GMT). No. of bitstreams: 2 MARCELO VARASCHIN GEHM.pdf: 579818 bytes, checksum: ab3693a439153cd17184df2fc888ec66 (MD5) license_rdf: 1232 bytes, checksum: 66e71c371cc565284e70f40736c94386 (MD5) Previous issue date: 2015-08-11 / As afecções do sistema locomotor são um dos problemas mais evidenciados em equinos da raça Crioula, devido às adaptações que estes animais vêm sendo submetidos, principalmente no que tange à alimentação, manejo e treinamento. Dentre estas, destaca-se a osteoartrite társica distal, que pode acarretar perda de desempenho e, até mesmo retirada precoce da atividade atlética. Dessa forma, objetivou-se neste estudo verificar a existência e frequência de comunicação entre as articulações társicas em equinos da raça crioula, além de avaliar a eficiência da técnica de artrografia do tarso, a fim de facilitar procedimentos diagnósticos e terapêuticos. Foram utilizados 50 (100 tarsos) cavalos crioulos de ambos os sexos, de 3 a 8 anos de idade. Destes, 30 tarsos foram excluídos do estudo devido a alterações radiográficas com perda de espaço articular. Os animais foram infiltrados na articulação intertársica distal com contraste positivo e radiografados para constatação de possível comunicação entre as articulações társicas. Verificou-se que em 42,9% dos tarsos não ocorreu qualquer passagem do contraste. Em 54,3% foi observado que o contraste passou para a articulação tarsometatársica e em 11,5% o contraste subiu para as articulações proximais do tarso. Concluiu-se com o presente trabalho que a técnica artrográfica do tarso com o acesso da articulação intertársica distal mostrou-se eficiente, porém com extravasamento do contraste para a bolsa do tendão cuneano em um número expressivo de tarsos e que existe uma porcentagem importante de comunicação entre as articulações distais e proximais do tarso na raça crioula, ressaltando a importância da artrografia antes de procedimentos diagnósticos e, principalmente, terapêuticos. / The disorders of the locomotor system in Crioulo horses are one of the most evident problems due to the adaptations they have been submitted, mainly related to feeding, management and physical training of these animals. Among these disorders, there is the distal tarsal osteoarthritis, which can cause loss of performance and even early withdrawal of athletic activity. Therefore, the objective of this study was to verify the existence of communication between the tarsal joints in Crioulo horses and to evaluate the efficiency of access to distal intertarsal joint in order to facilitate diagnostic and therapeutic procedures. 50 Crioulo horses were used, of both sexes, 3-8 years old, of which 30 tarsus were excluded from the experiment because they had radiographic changes in the region. In all the others, an infiltration of contrast in the distal intertarsal joint and a radiograph were carried out to find possible communication between the tarsal joints. It was found there was no passage of contrast in 42.9% of the tarsus. In 54.3% it was observed that the contrast has spread to the tarsometatarsal joint and 11.5% to proximal tarsal joints. We conclude with this study that tarsal arthrography technique to access the distal intertarsal joint proved to be efficient, but with contrast extravasation into the bag of cunean tendon in a significant number of shanks and that there is a significant percentage of communication between the proximal and distal tarsal joints in the Crioulo horses, highlighting the importance of arthrography before diagnostic and therapeutic procedures.
160

Estudo da condutividade hidráulica e do potencial de lixiviação de fósforo em colunas de solo compactado

Chimbida, Janete Terezinha 29 May 2006 (has links)
Made available in DSpace on 2017-05-12T14:48:03Z (GMT). No. of bitstreams: 1 Janete Terezinha Chimbida.pdf: 933108 bytes, checksum: 8674521518101715064fb24da02f65dd (MD5) Previous issue date: 2006-05-29 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / To present research it was developed in the Universidade Estadual do Oeste do Paraná -UNIOESTE, using the Laboratório de Geotecnia for assembly of the experiment and the Laboratório de Saneamento for chemical analyses. The coming of the processes liquid and solid residues and activities agro industries have as characteristic common to high nutrients load, above all Nitrogen and Phosphorous. When these materials are disposed in a of wastes contention system without correct impermeabilization it can happen the contamination of the groundwater. The objective of this work is to verify the quality of typical distroferric Red Oxisol, of wide regional occurrence, compacted in what it says respect to the permeability; the lixiviation potential of the phosphate; accumulation of the phosphate in the soil and the alterations happened in the soil matrix after the percolation of the swine effluent. The experiment was driven in laboratory scale, being set up a total of 27 columns of PVC tubes, of 1,15m of length and 0,10m of diameter, being in the compacted base 0,03m of soil in three moisture contents (28, 32 and 36%) and applied gross swine effluent (E1), diluted swine effluent (E2) and distilled water (E3), making three repetitions, percolating for at the most 15 days or 8 times the total volume of pores (VP), picking up samples of 25 mL, evaluating the pH, CE and phosphate. Then the columns were dismounted, removing the hydraulic load and dividing the soil in three increments: 0 to -1 cm, -1 at -2 cm and -2 to -3 cm. Discarded the middle increment. It was conduced the analysis of the content organic matter (MO), total and uptake of phosphorous, it was also determined the pH, the zero point charge (ZPC) and the surface potential. The results showed reduction in the permeability with the application of swine effluent to at levels that indicate a possible colmatation; the measures of electric conductivity (CE) were smaller than the initials in the effluents, and the retention of particles was shown with an decrease in the soil surface potential; as the percolation of the phosphate, it was minimum and it happened in the treatments with the soil was not appropriately compacted. The soil analysis showed that the phosphate was retained in the superior increment. / A presente pesquisa foi desenvolvida na Universidade Estadual do Oeste do Paraná UNIOESTE Campus de Cascavel, utilizando o Laboratório de Geotecnia para a montagem do experimento e o Laboratório de Saneamento para a realização das análises químicas. Os resíduos líquidos e sólidos provenientes dos processos e atividades agroindustriais têm como característica comum a alta carga de nutrientes, sobretudo Nitrogênio e Fósforo. Quando esses materiais são dispostos em um sistema de contenção de rejeitos, sem a correta impermeabilização, pode ocorrer a contaminação das águas subterrâneas. O objetivo deste trabalho foi verificar a qualidade do Latossolo Vermelho distroférrico típico, de larga ocorrência regional, compactado, em relação à permeabilidade; ao potencial de lixiviação do fosfato; à acumulação do fosfato no solo e às alterações ocorridas na matriz do solo, após a percolação do efluente de suíno. O experimento foi conduzido em escala de laboratório, montando-se um total de 27 colunas de tubos de PVC, de 1,15 m de comprimento e 0,10 m de diâmetro, compactado na base 0,03 m de solo em três teores de umidade (28, 32 e 36%) e aplicado efluente de suíno bruto (E1), efluente de suíno diluído (E2) e água destilada (E3), com três repetições. Deixou-se percolar por no máximo 15 dias ou 8 vezes o volume total de poros (VP), recolhendo-se amostras de 25 mL, para avaliação do pH, da condutividade elétrica (CE) e da concentração de fosfato. Em seguida, as colunas foram desmontadas, removendo-se a carga hidráulica e dividindo-se o solo em três incrementos: 0 a 1 cm, -1 a 2 cm e 2 a 3 cm. Nos incrementos superior e inferior, realizou-se a análise do teor de matéria orgânica (MO), fósforo total e fósforo assimilável e determinou-se o pH, o ponto de carga zero (PCZ) e o potencial elétrico de superfície, sendo que o incremento do meio foi descartado. Os resultados mostraram redução na permeabilidade com a aplicação de efluente de suíno a níveis que indicam uma possível colmatação; as medidas de condutividade elétrica (CE) foram menores que as iniciais nos efluentes. Verificou-se a retenção de partículas com um decréscimo no potencial de superfície no solo; quanto à percolação do fosfato, foi mínima e ocorreu nos tratamentos em que o solo não foi compactado adequadamente. A análise de solo mostrou que o fosfato ficou retido no incremento superior.

Page generated in 0.0341 seconds