Spelling suggestions: "subject:"solo compacta"" "subject:"solo impactado""
1 |
Comportamento de variedades de soja em condições de solo compactado e níveis de irrigaçãoOliveira, Paula Regina [UNESP] 22 July 2011 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:23:10Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-07-22Bitstream added on 2014-06-13T19:29:13Z : No. of bitstreams: 1
oliveira_pr_me_jabo.pdf: 426856 bytes, checksum: 02bdd1b26626af74a0b23fa46be6ef5f (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo do vigente trabalho foi avaliar a qualidade física de um LATOSSOLO VERMELHO Eutroférrico, textura argilosa, cultivado com as variedades de soja (CAC-1 e FT-Cristalina), submetidos aos efeitos da compactação e da irrigação, utilizando os atributos físicos do solo e associá-los ao crescimento radicular e à produtividade da cultura da soja, em experimentos conduzidos em campo e em casa de vegetação (vasos). O experimento de campo constou de parcelas subdivididas, com quatro repetições cujos tratamentos principais foram constituídos por quatro níveis de compactação, proporcionados pelo tráfego controlado de tratores, três níveis de irrigação e duas camadas de solo (Capítulos 2 e 3). Foram coletadas amostras indeformadas do solo nas camadas de 0-0,10 e 0,10-0,20 m, para determinação dos atributos físicos. A produtividade máxima da soja foi obtida com a resistência do solo à penetração de 0,71 e 1,88 MPa para as variedades CAC-1 e FT-Cristalina, respectivamente. Foi obtido o valor de “S” de 0,036 e redução nos níveis mais compactados para 0,026. O experimento de casa de vegetação apresentou parcelas subdivididas com três repetições cujas variedades CAC-1 e FT-Cristalina diminuíram o comprimento de raízes à medida que aumentou a compactação e consequentemente reduziu a área explorada pelas raízes (Capítulo 4) / The aim of the current study was to evaluate the physical quality of an Eutrustox, clayey texture, cultivated with soybean varieties (CAC-1 and FT-Cristalina), submitted to the effects of soil compaction and irrigation, using the physical attributes of soil and associates them to root growth and yield of soybean culture, in experiments conducted in field and greenhouse (vases). The field experiment consisted of split plots, with four replications, where the main treatments was consisted of four levels of compaction, induced by controlled tractors traffic, three levels of irrigation and two layers of soil (Chapters 2 and 3). Undisturbed samples of soil were collected in the layers of 0-0,10 and 0,10-0,20 m, to determine the physical attributes. The maximum yield of soybeans was obtained with the soil resistance to penetration of 0,71 and 1,88 MPa for the varieties CAC-1 and FT-Cristalina, respectively. It was obtained the S value of 0,036 and a reduction in the levels more compressed to 0,026. The greenhouse experiment showed a split plot design with three replications whose varieties CAC-1 and FT-Cristalina decreased the root length as increased the compaction and consequently reduced the area explored by the roots (Chapter 4)
|
2 |
Ensaios pressiométricos de Ménard em maciços compactados para a avaliação de módulos elásticos / Ménard pressuremeter tests in a massive compressed to the evaluation of elastic moduliOLIVEIRA, Devonzir Magalhães de 17 December 2010 (has links)
Made available in DSpace on 2014-07-29T15:18:21Z (GMT). No. of bitstreams: 1
Devonzir Magalhaes.pdf: 2374656 bytes, checksum: be2fa62f68b635119a439a5c539c3894 (MD5)
Previous issue date: 2010-12-17 / The compacting control of earthy materials at engineering works demands great efforts and
the necessity of conducting field and laboratory tests in time and space, conditioned by the
work schedule always tight. It is also known that the embankment supports the efforts of
substantial bodies of water with potential energy, which if, uncontrollably released, will cause
tragedies and imponderable material damages. This work presents the methodology of
execution and analysis of the results of field and laboratory tests performed in two
experimental embankments builted during the definition of the construction s processes of the
Batalha Hydroelectric Power Plant. It was collected disturbed and undisturbed samples at
twelve spot in each embankment, to perform characterization tests, triaxial compression test
and consolidation test. The results of these laboratory tests where compared to the results of
twenty four Pressuremeter Tests (PMT) fulfilled at the same embankment. The interpretation
of the PMT tests was done according to french standards. These tests provided results of
Ménard Pressuremeter Modulus (EM), pressuremeter limit pressure (pl) and creep pressure
(pf), which corresponds to the end of the elastic range of the material. In addition, it was
performed twenty four Standard Penetration Tests in both embankments to obtain the Nspt and
compare with the results of PMT. The studies developed in this research showed that these
tests point out results with less variability that the ones from the laboratories and can be
realized with no difficulties along the soil profile. The results achieved demonstrated that the
PMT can be a very useful tool to reach the modulus of elasticity at any depth of the landfill,
mainly in rolled-fill dams already operating a long time and in places where there are
restrictions to remove samples for laboratory tests. / O controle de compactação de materiais terrosos em obras de engenharia demanda grandes
esforços e a necessidade da realização de ensaios de campo e laboratório, ajustados ao
cronograma sempre apertado das obras. Sabe-se, também, que os aterros compactados de
barragens suportam esforços de grandes massas de água com energia potencial que se
liberadas, incontrolavelmente, causarão tragédias e danos materiais incalculáveis. Este
trabalho apresenta a metodologia de execução e análise dos resultados de ensaios de campo e
laboratório realizados em dois aterros experimentais construídos na fase de definição dos
processos construtivos da barragem da UHE Batalha. Foram coletadas amostras deformadas e
blocos de amostras indeformadas de doze pontos em cada aterro, para caracterização do solo
compactado e realização de ensaios de compressão triaxial e de adensamento. Os resultados
desses ensaios de laboratório foram comparados com os resultados de vinte e quatro ensaios
pressiométricos (PMT) executados nos mesmos aterros. Na interpretação dos ensaios PMT foi
empregada a metodologia das normas francesas. Estes ensaios forneceram resultados do
módulo de elasticidade de Ménard (EM), pressão limite (pl) e pressão de fluência (pf), esta
correspondente ao fim da fase pseudo-elástica do material. Complementarmente foram
realizados vinte e quatro ensaios penetrométricos nos dois aterros para obtenção do NSPT e
comparação com os resultados do PMT. Os estudos desenvolvidos nesta pesquisa mostraram
que estes ensaios apresentaram resultados com menor variabilidade que os ensaios de
laboratório e podem ser realizados sem muitas dificuldades ao longo do perfil de um aterro
compactado. Os resultados alcançados mostraram que o PMT poderá se tornar uma
ferramenta de grande utilidade para obtenção do módulo de elasticidade em quaisquer
profundidades de aterros compactados, principalmente em barragens antigas e em locais
destas onde possam existir restrições para retirada de amostras para ensaios de laboratório.
|
3 |
Análise comparativa entre alguns métodos de ensaio de tração de solos compactados / not availableGaioto, Nélio 10 February 1973 (has links)
Para a elaboração do presente trabalho foram considerados quatro variáveis: o método de ensaio, o tipo de solo, a umidade e o grau de compactação dos corpos de prova. Considerando-se três níveis de variáveis para cada caso resultam 34 = 81 combinações possíveis. Procurou-se desenvolver o trabalho tendo por base este número de combinações. No entanto, com o intuito de se obter também algumas comparações com resultados de ensaios de compressão, bem como o de se determinar algumas envoltórias de resistência ao cisalhamento, o número de ensaios ultrapassou a quantidade prevista. Por outro lado, alguns resultados, considerados inaceitáveis, por imperfeições observadas durante os ensaios, ou por se apresentarem incompatíveis com os demais, foram abandonados. / not available
|
4 |
Estudo da condutividade hidráulica e do potencial de lixiviação de fósforo em colunas de solo compactadoChimbida, Janete Terezinha 29 May 2006 (has links)
Made available in DSpace on 2017-07-10T19:24:40Z (GMT). No. of bitstreams: 1
Janete Terezinha Chimbida.pdf: 933108 bytes, checksum: 8674521518101715064fb24da02f65dd (MD5)
Previous issue date: 2006-05-29 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / To present research it was developed in the Universidade Estadual do Oeste do Paraná -UNIOESTE, using the Laboratório de Geotecnia for assembly of the experiment and the Laboratório de Saneamento for chemical analyses. The
coming of the processes liquid and solid residues and activities agro industries have as characteristic common to high nutrients load, above all Nitrogen and Phosphorous. When these materials are disposed in a of wastes contention
system without correct impermeabilization it can happen the contamination of the groundwater. The objective of this work is to verify the quality of typical distroferric Red Oxisol, of wide regional occurrence, compacted in what it says
respect to the permeability; the lixiviation potential of the phosphate; accumulation of the phosphate in the soil and the alterations happened in the soil matrix after the percolation of the swine effluent. The experiment was driven
in laboratory scale, being set up a total of 27 columns of PVC tubes, of 1,15m of length and 0,10m of diameter, being in the compacted base 0,03m of soil in three moisture contents (28, 32 and 36%) and applied gross swine effluent (E1),
diluted swine effluent (E2) and distilled water (E3), making three repetitions, percolating for at the most 15 days or 8 times the total volume of pores (VP), picking up samples of 25 mL, evaluating the pH, CE and phosphate. Then the
columns were dismounted, removing the hydraulic load and dividing the soil in three increments: 0 to -1 cm, -1 at -2 cm and -2 to -3 cm. Discarded the middle increment. It was conduced the analysis of the content organic matter (MO),
total and uptake of phosphorous, it was also determined the pH, the zero point charge (ZPC) and the surface potential. The results showed reduction in the permeability with the application of swine effluent to at levels that indicate a
possible colmatation; the measures of electric conductivity (CE) were smaller than the initials in the effluents, and the retention of particles was shown with an decrease in the soil surface potential; as the percolation of the phosphate, it
was minimum and it happened in the treatments with the soil was not appropriately compacted. The soil analysis showed that the phosphate was retained in the superior increment. / A presente pesquisa foi desenvolvida na Universidade Estadual do Oeste do Paraná UNIOESTE Campus de Cascavel, utilizando o Laboratório de Geotecnia para a montagem do experimento e o Laboratório de Saneamento para a realização das análises químicas. Os resíduos líquidos e sólidos provenientes dos processos e atividades agroindustriais têm como característica comum a alta carga de nutrientes, sobretudo Nitrogênio e Fósforo. Quando esses materiais são dispostos em um sistema de contenção de rejeitos, sem a correta impermeabilização, pode ocorrer a contaminação das
águas subterrâneas. O objetivo deste trabalho foi verificar a qualidade do Latossolo Vermelho distroférrico típico, de larga ocorrência regional, compactado, em relação à permeabilidade; ao potencial de lixiviação do fosfato; à acumulação do fosfato no solo e às alterações ocorridas na matriz do solo, após a percolação do efluente de suíno. O experimento foi conduzido em escala de laboratório, montando-se um total de 27 colunas de tubos de PVC,
de 1,15 m de comprimento e 0,10 m de diâmetro, compactado na base 0,03 m de solo em três teores de umidade (28, 32 e 36%) e aplicado efluente de suíno bruto (E1), efluente de suíno diluído (E2) e água destilada (E3), com três repetições. Deixou-se percolar por no máximo 15 dias ou 8 vezes o volume
total de poros (VP), recolhendo-se amostras de 25 mL, para avaliação do pH, da condutividade elétrica (CE) e da concentração de fosfato. Em seguida, as colunas foram desmontadas, removendo-se a carga hidráulica e dividindo-se o solo em três incrementos: 0 a 1 cm, -1 a 2 cm e 2 a 3 cm. Nos incrementos superior e inferior, realizou-se a análise do teor de matéria orgânica (MO), fósforo total e fósforo assimilável e determinou-se o pH, o ponto de carga zero
(PCZ) e o potencial elétrico de superfície, sendo que o incremento do meio foi descartado. Os resultados mostraram redução na permeabilidade com a aplicação de efluente de suíno a níveis que indicam uma possível colmatação;
as medidas de condutividade elétrica (CE) foram menores que as iniciais nos efluentes. Verificou-se a retenção de partículas com um decréscimo no potencial de superfície no solo; quanto à percolação do fosfato, foi mínima e ocorreu nos tratamentos em que o solo não foi compactado adequadamente. A análise de solo mostrou que o fosfato ficou retido no incremento superior.
|
5 |
Estudo da condutividade hidráulica e do potencial de lixiviação de fósforo em colunas de solo compactadoChimbida, Janete Terezinha 29 May 2006 (has links)
Made available in DSpace on 2017-05-12T14:48:03Z (GMT). No. of bitstreams: 1
Janete Terezinha Chimbida.pdf: 933108 bytes, checksum: 8674521518101715064fb24da02f65dd (MD5)
Previous issue date: 2006-05-29 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / To present research it was developed in the Universidade Estadual do Oeste do Paraná -UNIOESTE, using the Laboratório de Geotecnia for assembly of the experiment and the Laboratório de Saneamento for chemical analyses. The
coming of the processes liquid and solid residues and activities agro industries have as characteristic common to high nutrients load, above all Nitrogen and Phosphorous. When these materials are disposed in a of wastes contention
system without correct impermeabilization it can happen the contamination of the groundwater. The objective of this work is to verify the quality of typical distroferric Red Oxisol, of wide regional occurrence, compacted in what it says
respect to the permeability; the lixiviation potential of the phosphate; accumulation of the phosphate in the soil and the alterations happened in the soil matrix after the percolation of the swine effluent. The experiment was driven
in laboratory scale, being set up a total of 27 columns of PVC tubes, of 1,15m of length and 0,10m of diameter, being in the compacted base 0,03m of soil in three moisture contents (28, 32 and 36%) and applied gross swine effluent (E1),
diluted swine effluent (E2) and distilled water (E3), making three repetitions, percolating for at the most 15 days or 8 times the total volume of pores (VP), picking up samples of 25 mL, evaluating the pH, CE and phosphate. Then the
columns were dismounted, removing the hydraulic load and dividing the soil in three increments: 0 to -1 cm, -1 at -2 cm and -2 to -3 cm. Discarded the middle increment. It was conduced the analysis of the content organic matter (MO),
total and uptake of phosphorous, it was also determined the pH, the zero point charge (ZPC) and the surface potential. The results showed reduction in the permeability with the application of swine effluent to at levels that indicate a
possible colmatation; the measures of electric conductivity (CE) were smaller than the initials in the effluents, and the retention of particles was shown with an decrease in the soil surface potential; as the percolation of the phosphate, it
was minimum and it happened in the treatments with the soil was not appropriately compacted. The soil analysis showed that the phosphate was retained in the superior increment. / A presente pesquisa foi desenvolvida na Universidade Estadual do Oeste do Paraná UNIOESTE Campus de Cascavel, utilizando o Laboratório de Geotecnia para a montagem do experimento e o Laboratório de Saneamento para a realização das análises químicas. Os resíduos líquidos e sólidos provenientes dos processos e atividades agroindustriais têm como característica comum a alta carga de nutrientes, sobretudo Nitrogênio e Fósforo. Quando esses materiais são dispostos em um sistema de contenção de rejeitos, sem a correta impermeabilização, pode ocorrer a contaminação das
águas subterrâneas. O objetivo deste trabalho foi verificar a qualidade do Latossolo Vermelho distroférrico típico, de larga ocorrência regional, compactado, em relação à permeabilidade; ao potencial de lixiviação do fosfato; à acumulação do fosfato no solo e às alterações ocorridas na matriz do solo, após a percolação do efluente de suíno. O experimento foi conduzido em escala de laboratório, montando-se um total de 27 colunas de tubos de PVC,
de 1,15 m de comprimento e 0,10 m de diâmetro, compactado na base 0,03 m de solo em três teores de umidade (28, 32 e 36%) e aplicado efluente de suíno bruto (E1), efluente de suíno diluído (E2) e água destilada (E3), com três repetições. Deixou-se percolar por no máximo 15 dias ou 8 vezes o volume
total de poros (VP), recolhendo-se amostras de 25 mL, para avaliação do pH, da condutividade elétrica (CE) e da concentração de fosfato. Em seguida, as colunas foram desmontadas, removendo-se a carga hidráulica e dividindo-se o solo em três incrementos: 0 a 1 cm, -1 a 2 cm e 2 a 3 cm. Nos incrementos superior e inferior, realizou-se a análise do teor de matéria orgânica (MO), fósforo total e fósforo assimilável e determinou-se o pH, o ponto de carga zero
(PCZ) e o potencial elétrico de superfície, sendo que o incremento do meio foi descartado. Os resultados mostraram redução na permeabilidade com a aplicação de efluente de suíno a níveis que indicam uma possível colmatação;
as medidas de condutividade elétrica (CE) foram menores que as iniciais nos efluentes. Verificou-se a retenção de partículas com um decréscimo no potencial de superfície no solo; quanto à percolação do fosfato, foi mínima e ocorreu nos tratamentos em que o solo não foi compactado adequadamente. A análise de solo mostrou que o fosfato ficou retido no incremento superior.
|
6 |
Análise comparativa entre alguns métodos de ensaio de tração de solos compactados / not availableNélio Gaioto 10 February 1973 (has links)
Para a elaboração do presente trabalho foram considerados quatro variáveis: o método de ensaio, o tipo de solo, a umidade e o grau de compactação dos corpos de prova. Considerando-se três níveis de variáveis para cada caso resultam 34 = 81 combinações possíveis. Procurou-se desenvolver o trabalho tendo por base este número de combinações. No entanto, com o intuito de se obter também algumas comparações com resultados de ensaios de compressão, bem como o de se determinar algumas envoltórias de resistência ao cisalhamento, o número de ensaios ultrapassou a quantidade prevista. Por outro lado, alguns resultados, considerados inaceitáveis, por imperfeições observadas durante os ensaios, ou por se apresentarem incompatíveis com os demais, foram abandonados. / not available
|
7 |
[en] INFLUENCE OF CLAY CONTENT AND SUCTION ON THE STRENGTH OF COMPRESSED EARTH BLOCKS / [pt] INFLUÊNCIA DO TEOR DE ARGILA E DA SUCÇÃO NA RESISTÊNCIA DOS BLOCOS DE SOLO COMPACTADOALEXANDR ZHEMCHUZHNIKOV 26 July 2016 (has links)
[pt] Solo é um material de construção sustentável que tem sido utilizado por
milhares de anos. As normas técnicas e recomendações existentes referente à
construção de terra são baseadas em número limitado de estudos e dependem de
materiais, condições climáticas e tradições locais. A compreensão dos parâmetros
que influenciam o comportamento do solo compactado quando o mesmo utilizado
em paredes e colunaas é essencial para a interpretação dos dados experimentais.
Diversos estudos recentes analizaram taipa de pilão do ponto de vista da mecanica
de solos nçao saturados, observando o decrescimo da resistência com a
diminuição da sucção, causada por exemplo pelo aumento da humidade do ar.
Porém, não hã uma pesquisa semelhante pertinente aos blocos de solo
compactado. O objetivo do presente trabalho foi verificar a influência do teor de
argila, dencidade e sucção na resistência dos blocos de solo compactado. Foram
utiliazdas quatro dosagens de solo artificial que consistiu de areia, pó de quartzo e
argila caulitinitca. Para cada dosagem, amostras estaticamente compactadas na
umidade ótima e no ramo seco foram ensaiadas variando-se a sucção. Ao
contrário dos resultados encontrados comunmente na literatura, a resistência das
amostras diminuiu com o aumento da sucção, enquanto a influência das condições
climáticas como umidade e temperatura foram mínimas. As conclusões feitas no
presente trabalho podem ser utilizadas nos projetos de construção sustentável com
emprego de blocos de solo compactado. / [en] Soil is a sustainable construction material that has been used traditionally for
thousands of years. In general, earth construction specifications are based on
common knowledge. Existing recommendations tend to be supported by a limited
number of studies and depend on local materials, climatic conditions and
historical background. The lack of understanding of compacted soil behavior, in
particularly its strength, may have prevented a wider application of earthen
construction materials in housing. Understanding of the soil properties and
parameters that influence its performance when used in walls and columns is
essential for interpretation of experimental data. Recently a number of studies
have analyzed rammed earth considering unsaturated soil mechanics, which
suggest loss of strength following decrease in suction values, for example
provoked by the increase in relative humidity. However, there is a lack of such
research pertaining to compressed earth blocks (CEBs). The objective of this
study was to verify the influence of clay content, density and suction on the
strength of CEBs. Four soil mixes consisting of sand, quartz powder and
kaolinitic clay were used. For each soil mix statically compacted samples with
densities corresponding to optimum and dry of optimum moisture contents were
tested for a range of suctions. Unlike reported in the literature, the results showed
loss of strength following increase in suction values, while only small variations
were registered for suctions corresponding to a wide range of RH and temperature
conditions. The findings can be of use for specifications relating to construction
of sustainable housing using CEBs.
|
8 |
Estudo de mistura de solos para impermeabilização eficiente de camada de base de aterros sanitários.SILVA, Thiago Fernandes da. 13 April 2018 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-04-13T20:50:04Z
No. of bitstreams: 1
THIAGO FERNANDES DA SILVA – DISSERTAÇÃO (PPGECA) 2017.pdf: 2028190 bytes, checksum: 54afe9db3986c5fc9afbadce4f2e7f1c (MD5) / Made available in DSpace on 2018-04-13T20:50:04Z (GMT). No. of bitstreams: 1
THIAGO FERNANDES DA SILVA – DISSERTAÇÃO (PPGECA) 2017.pdf: 2028190 bytes, checksum: 54afe9db3986c5fc9afbadce4f2e7f1c (MD5)
Previous issue date: 2017-08 / Capes / Os aterros sanitários representam a alternativa mais utilizada em todo mundo para disposição ambientalmente adequada de Resíduos Sólidos Urbanos (RSU), sendo sua camada de base (liners) um dos principais componentes. A ausência de cuidados com essas camadas podem gerar danos ambientais imensuráveis, como a infiltração de lixiviado para corpos hídricos superficiais e lençóis freáticos próximos, além de contaminação do solo. O coeficiente de permeabilidade à água é a principal variável utilizada para verificar a eficiência das liners. Dentro desse contexto, este trabalho tem como objetivo obter uma composição adequada de solos para camada de base de aterro sanitário atendendo às exigências de permeabilidade à água de acordo com padrões nacionais e internacionais. O campo experimental para esta pesquisa foi o aterro sanitário no município de Campina Grande – PB, que utiliza uma composição entre dois tipos de solos para camada em estudo. Inicialmente, foram realizadas caracterizações geotécnicas, físico-químicas e mineralógicas desses dois tipos de solos, sendo denominados de Solo 1 aquele obtido na área do empreendimento e Solo 2 obtidos em jazidas no município de Boa Vista – PB. Aplicou-se a técnica do planejamento fatorial na qual foram avaliadas as variáveis da mistura: energia de compactação, umidade e porcentagem de Solo 2. Com isso, foi possível otimizar o processo de interação entre as variáveis de controle e reduzir o número de ensaios realizados. Foram utilizados os delineamentos composto central (modelo plano) e composto central rotacional (modelo com curvatura). Para determinação da permeabilidade à água, foi selecionado o modelo que apresentou melhor ajuste, de acordo com o Critério de Akaike (AiC), a Soma dos Quadrados dos Resíduos (SQR) e o Coeficiente de Determinação (R²). O valor de K admissível foi determinado de acordo exigências da Companhia Ambiental do Estado de São Paulo (CETESB), da Associação Brasileira de Normas Técnicas (ABNT) e da Agência de Proteção Ambiental Americana (EPA). O Solo 1 é uma areia mal graduada argilosa e o Solo 2 é um material com presença argilominerais esmectíticos, apresentando Índice de Plasticidade (IP) de 124%. O modelo que apresentou melhor ajuste foi o plano. Foram obtidos valores de K: energia de compactação de 0,476 MN.m/m³, umidade de 8,285% e porcentagem de Solo 2 de 29,685%. Como o Solo 1 apresenta percentual granulométrico de areia elevado (89,67%), a porcentagem de Solo 2 obtida para a mistura é necessária para preencher os interstícios do Solo 1, com umidade suficiente para lubrificar as partículas e energia de compactação suficiente para fornecer a acomodação destas partículas. Com isso, foi possível obter uma camada de base adequada para o aterro sanitário em estudo atendendo às exigências de permeabilidade à água de acordo com padrões nacionais e internacionais, permitindo que este estudo seja aplicado também a aterros com características semelhantes, podendo ainda, com esses resultados, ser sugerido o redirecionamento na operação destes aterros. / Landfills represent the most widely used worldwide alternative for the environmentally sound disposal of Urban Solid Waste (RSU), with its liners being one of the main components. Lack of care with these layers can generate immeasurable environmental damage, such as leachate infiltration to nearby surface water bodies and groundwater, in addition to soil contamination. The water permeability coefficient is the main variable used to verify liners efficiency. Within this context, this work aims to obtain an adequate composition of soils for the base layer of landfill, meeting the water permeability requirements according to national and international standards. The experimental field for this research was the sanitary landfill in the city of Campina Grande - PB, which uses a composition between two types of soils for the study layer. Initially, geotechnical, physical-chemical and mineralogical characterizations of these two types of soils were carried out, being called of Soil 1 that obtained in the area of the project and Soil 2 obtained in deposits in the municipality of Boa Vista - PB. The technique of factorial planning was applied in which the variables of the mixture were evaluated: energy of compaction, humidity and percentage of Soil 2. With this, it was possible to optimize the interaction process between the control variables and to reduce the number of tests performed . The central composite (plane model) and rotational central composite (curvature model) were used. To determine the permeability to water, the model that presented the best fit was selected according to the Akaike criterion (AiC), the sum of squares of the residuals (SQR) and the coefficient of determination (R²). The admissible K value was determined in accordance with requirements of the Environmental Protection Agency of the State of São Paulo (CETESB), the Brazilian Association of Technical Standards (ABNT) and the American Environmental Protection Agency (EPA). Soil 1 is a clayey poorly graded sand and Soil 2 is a material with smectite clayey minerals, with a Plasticity Index (PI) of 124%. The model that presented the best fit was the plan. K values were obtained: compaction energy of 0.476 MN.m / m³, humidity of 8.285% and Soil 2 percentage of 29.685%. Since Soil 1 has a high sand particle size (89.67%), the percentage of Soil 2 obtained for the mixture is required to fill the interstices of Soil 1, with sufficient moisture to lubricate the particles and sufficient compaction energy to provide the accommodation of these particles. With this, it was possible to obtain a suitable base layer for the sanitary landfill under study, meeting the requirements of water permeability according to national and international standards, allowing this study to be applied also to landfills with similar characteristics. redirecting the operation of these landfills.
|
9 |
Adsorção de metais tóxicos em liners de solo compactado em aterros sanitários. / Adsortion of toxic metals in compacted soil liners in sanitary lands.SILVA, Daniela Lima Machado da. 24 August 2018 (has links)
Submitted by Maria Medeiros (maria.dilva1@ufcg.edu.br) on 2018-08-24T11:49:53Z
No. of bitstreams: 1
DANIELA LIMA MACHADO DA SILVA - DISSERTAÇÃO (PPGECA) 2018.pdf: 1711823 bytes, checksum: c48feb8c7f2a334be9eb3ff6467dc92c (MD5) / Made available in DSpace on 2018-08-24T11:49:53Z (GMT). No. of bitstreams: 1
DANIELA LIMA MACHADO DA SILVA - DISSERTAÇÃO (PPGECA) 2018.pdf: 1711823 bytes, checksum: c48feb8c7f2a334be9eb3ff6467dc92c (MD5)
Previous issue date: 2018-03-19 / Nos aterros sanitários, a camada de base usada para a impermeabilização deve garantir que não haja migração de poluentes para o meio ambiente, sendo denominada de liner. A avaliação dos mecanismos que regem o transporte de contaminantes nos materiais geológicos pode ser realizada em laboratório por meio de ensaios de equilíbrio em lote, que consiste em uma forma rápida de estimar a adsorção de cátions metálicos pelos solos. O objetivo desse trabalho foi avaliar a adsorção de metais tóxicos em dois liners de solos compactados, com composições diferentes, utilizando os ensaios de equilíbrio em lote. Os solos estudados compreendem ao liner da base de uma célula experimental, que simula um aterro sanitário, e um liner da base de um aterro em escala real, localizado no município de Campina Grande-PB. O liner usada na célula experimental é composta por solo natural compactado, enquanto que no aterro sanitário, foi realizada a adição de bentonita ao solo local, sendo essa mistura, posteriormente, compactada. As amostras de solos do liner da célula experimental foram coletadas em uma jazida localizada no município de Boa Vista-PB, a qual encontra-se situado a 50 km do município de Campina Grande-PB. O solo do liner usado no aterro sanitário, foi coletado na área do próprio aterro, que se localiza em Catolé de Boa Vista, distrito de Campina Grande-PB. As amostras dos respectivos liners foram coletadas, armazenadas no Laboratório de Geotecnia Ambiental, do Departamento de Engenharia Civil da Universidade Federal de Campina Grande, e preparadas para a caracterização geotécnica, físico-química e mineralógica. No ensaio de equilíbrio em lote foram utilizadas soluções com proporção solo-solução 1: 12,5 (4g de solo seco para 50 mL de solução). As isotermas experimentais obtidas foram ajustadas estatisticamente aos modelos físico-químicos de adsorção linear, de Langmuir e Freundlich. Os ajustes das curvas experimentais foram realizados pelo método interativo de Gauss-Newton. A ferramenta utilizada foi o software STATISTICA 8.0, utilizando modelos não-lineares e empregando o método dos mínimos quadrados, considerando como critério o maior coeficiente de determinação (R2). O modelo de Langmuir e de Freundlich se ajustaram melhor às isotermas do solo do liner da célula experimental, enquanto que a adsorção ocorrida no liner do aterro sanitário foi melhor ajustada ao modelo de Langmuir. Os diferentes solos estudados neste trabalho apresentaram propriedades adsortivas para todos os metais, o que o viabiliza para ser empregado em camadas de base de solo compactado para aterros sanitário, além de outras aplicações em geotecnia ambiental. Dentre os metais pesquisados, o chumbo se destacou por apresentar a maior adsorção em relação aos demais metais em ambos os solos. A caracterização geotécnica, físico-química e mineralógica, bem como o comportamento adsortivo dos solos, verificado por meio de ensaio de equilíbrio em lote, indica que os materiais estudados apresentam um relevante potencial para o uso em liners para aterros sanitários. / In sanitary landfills, the base layer used for waterproofing should ensure that there is no migration of pollutants into the environment and is called a liner. The evaluation of the mechanisms governing the transport of contaminants in the geological materials can be carried out in the laboratory by means of equilibrium tests in lot, which consists of a quick way of estimating the adsorption of metallic cations by the soils. The objective of this work was to evaluate the adsorption of toxic metals in two liners of compacted soils, with different compositions, using the equilibrium assays in lot. The studied soils comprise the base liner of an experimental cell, which simulates a sanitary landfill, and a liner from the base of a real-scale landfill, located in the municipality of Campina Grande-PB. The liner used in the experimental cell is composed of compacted natural soil, while in the sanitary landfill, the addition of bentonite was carried out to the local soil, and this mixture was later compacted. Soil samples from the liner of the experimental cell were collected in a field located in the municipality of Boa Vista-PB, which is located at 50 km from the city of Campina Grande-PB. The soil of the liner used in the sanitary landfill was collected in the landfill site, which is located in Catolé de Boa Vista, a district in Campina Grande-PB. The samples of the respective liners were collected, stored in the Laboratory of Environmental Geotechnics, from the Department of Civil Engineering in the Federal University of Campina Grande, and prepared for the geotechnical, physical-chemical and mineralogical characterization. In the equilibrium assay in lot, solutions with 1: 12,5 soil-solution ratio (4g of dry soil for 50 ml solution) were used. The experimental isotherms obtained were statistically adjusted to the physical-chemical models of linear adsorption, Langmuir and Freundlich. The adjustments of the experimental curves to the models were performed using the STATISTICA 8.0 software, applying the nonlinear regression of the least squares method, using the Gauss-Newton algorithm. Considering the R2 ≥ 0.7 criterion, the Langmuir and Freundlich model were better fitted to the liner soil isotherms of the experimental cell, while the adsorption occurred in the liner of the sanitary landfill was better fitted to the Langmuir model. The different soils studied in this work presented adsorptive properties for all metals, which makes it feasible to be used in compacted soil base layers for sanitary landfills, as well as other applications in environmental geotechnics. Among the metals studied, the Pb was distinguished by the higher adsorption in relation to the other metals in both soils. The geotechnical, physical-chemical and mineralogical characterization, as well as the adsorptive behavior of the soils, verified by means of a balance test in lot, indicates that the studied materials present a relevant potential for the use in liners for sanitary landfills.
|
10 |
Análise do desempenho de um solo compactado utilizado na camada de cobertura de um aterro sanitário.ARAUJO, Pabllo da Silva. 12 April 2018 (has links)
Submitted by Lucienne Costa (lucienneferreira@ufcg.edu.br) on 2018-04-12T20:13:37Z
No. of bitstreams: 1
PABLLO DA SILVA ARAUJO – DISSERTAÇÃO (PPGECA) 2017.pdf: 6927035 bytes, checksum: 9da5e680617a44b7eff618d9c75ffcf3 (MD5) / Made available in DSpace on 2018-04-12T20:13:37Z (GMT). No. of bitstreams: 1
PABLLO DA SILVA ARAUJO – DISSERTAÇÃO (PPGECA) 2017.pdf: 6927035 bytes, checksum: 9da5e680617a44b7eff618d9c75ffcf3 (MD5)
Previous issue date: 2017-03-29 / Capes / Uma das formas de tratamento de Resíduos Sólidos Urbanos (RSU) que mais se destaca são os aterros sanitários, que possui como vantagens, a facilidade de operação, menor custo quando comparado às outras técnicas (triagem, tratamento biológico, incineração, entre outras) e a existência de um plano de monitoramento contínuo. O aterro sanitário utiliza uma camada de cobertura final de solo compactado com a finalidade de isolar os resíduos do meio externo, minimizar a entrada de água para o interior do maciço sanitário, reduzir as emissões de gases para a atmosfera, evitar a proliferação de roedores e vetores de doença, entre outras. As Normas Brasileiras não regulamentam o tipo de solo a ser utilizado, nem técnicas de execução de camadas de coberturas de aterros, nem a forma de monitoramento, possuindo como única exigência o atendimento de um coeficiente mínimo de permeabilidade à água. Diante disso, este trabalho tem como objetivo analisar o desempenho do solo compactado utilizado na camada de cobertura final de um aterro de resíduos sólidos, tendo como campo experimental o Aterro Sanitário de Campina Grande/PB. Para isso foi realizada a caracterização física do solo utilizado na camada, verificação de seus parâmetros quanto à viabilidade para uso em aterros sanitários, análise físico-química e mineralógica, obtenção da curva de retenção de água no solo e análise dos pontos experimentais da curva aos ajustes propostos na literatura. Foi verificado o comportamento do solo frente aos processos de umedecimento/secagem e expansão/contração, observação da relação entre a umidade ótima de compactação e o ponto de entrada generalizada de ar (GAE), além da verificação da variação da umidade do solo em um perfil experimental da camada de cobertura por meio de sensores capacitivos. Os resultados demonstraram que, o solo possui permeabilidade à água
admissível para uso em aterros sanitários segundo as normas nacionais e internacionais. O ajuste da curva de Van Genuchten aos pontos experimentais da curva de retenção atendeu às condições de concordância a partir dos parâmetros estatísticos analisados. A umidade ótima de compactação do solo possui valor próximo ao GAE, onde se inicia a dessaturação do solo, no qual o ar começa a entrar nos maiores poros formados pela drenagem da água e perda de umidade. Deve-se realizar a compactação do solo na energia proctor normal obedecendo à adição de água suficiente para atingir a umidade ótima, em um intervalo aceitável de ± 2%. Pode-se concluir que, o tipo de camada de cobertura final (solo argiloso compactado) utilizado é inadequado para a região do aterro devido às características climatológicas a que o solo está submetido e a ausência de proteção vegetal superficial. A aplicação da energia proctor normal para compactação do solo da camada de cobertura do aterro sanitário proporciona condições favoráveis à redução da permeabilidade à água do solo. A curva de retenção de água no solo da camada de cobertura do aterro sanitário apresenta comportamento unimodal e possui características de um solo argiloso. A utilização de sensores capacitivos se mostrou como uma técnica eficaz para aquisição automática da umidade do solo e verificação da sua variação ao longo do tempo, bem como, o monitoramento da sucção pela espessura da
camada de cobertura final de solo compactado. / One of the forms of treatment of Municipal Solid Waste (MSW) is the landfill, which has the
advantages of ease of operation, lower cost when compared to other techniques (sorting,
biological treatment, incineration, among others) and the existence of a continuous monitoring plan. The landfill uses a final cover layer of compacted soil to isolate residues from the external environment, minimize the entry of water into the landfill, reduce the emission of gases into the atmosphere, prevent the proliferation of rodent and vectors of disease, among others. The Brazilian Regulations do not regulate the type of soil to be used, nor techniques for implementing layers of landfills, nor the form of monitoring, having as sole requirement the attendance of a minimum coefficient of water permeability. The objective of this work is to analyze the performance of the compacted soil used in the final cover layer of a landfill, with the Landfill Campina Grande/PB as an experimental field. The physical characterization of the soil used in the layer, verification of its parameters regarding the feasibility for use in landfills, physical-chemical and mineralogical analysis, obtaining the water retention curve in the soil and analysis of the experimental points of the curve were performed adjustments proposed in the literature. The behavior of the soil was verified in relation to the wetting/drying and swell/contraction processes, observation of the relation between the optimum compaction humidity and the Generalized Air Entry (GAE), besides the verification of soil moisture variation in one experimental profile of the cover layer by means of capacitive sensors. The results showed that the soil has permeability to water admissible for use in landfills according to national and international standards. The adjustment of the Van Genuchten curve to the experimental points of the retention curve met the conditions of agreement from the statistical parameters analyzed. The optimum soil compaction humidity has a value close to GAE, where soil desaturation begins, in which the air begins to enter the larger pores formed by water drainage and moisture loss. Soil compaction must be carried out in normal proctor energy by adding sufficient water to achieve optimum moisture, within an acceptable range of ± 2%. It can be concluded that the type of final cover layer (compacted clay soil) used is unsuitable for the landfill region due to the climatological characteristics to which the soil is subjected and the absence of surface vegetation protection. The application of normal proctor energy to soil compaction of the landfill cover layer provides favorable conditions for the reduction of soil water permeability. The water retention curve in the soil of the final cover layer of the landfill presents unimodal behavior and has characteristics of a clay soil. The use of capacitive sensors proved to be an effective technique for automatic acquisition of soil moisture and verification of its variation over time, as well as the monitoring of suction by the thickness of the final cover layer of compacted soil.
|
Page generated in 0.6377 seconds