Avaliação do impacto da geração distribuída sobre o sistema de proteção de sobrecorrente de uma rede de distribuição operando em ilhamento intencional / Impact assessment of the distributed generation on the overcurrent protection system of a distribution network operating in intentional islanding

Robson Roberto Sguaçabia 26 March 2015 (has links)
O crescente número de geradores distribuídos conectados em redes de distribuição de energia elétrica é uma realidade dos sistemas elétricos de todo o mundo. Embora a política atual seja desconectar os geradores distribuídos do sistema elétrico de potência (SEP) caso ocorra uma falha na rede da concessionária, conforme preconizam os principais guias técnicos nacionais e internacionais, o módulo 3 dos Procedimentos de Distribuição de Energia Elétrica no Sistema Elétrico Nacional (PRODIST) mostra-se favorável à operação ilhada, pois afirma que este tipo de operação pode ser realizado em comum acordo entre as centrais geradoras de energia e o Operador Nacional do Sistema Elétrico (ONS), permitindo alcançar uma maior disponibilidade no fornecimento de energia. No entanto, para que a operação ilhada seja possível e possa ser praticada de forma segura, o ilhamento intencional precisa superar alguns desafios, dentre os quais estão aqueles relacionados ao sistema de proteção da rede de distribuição, tais como: coordenação indevida de dispositivos de proteção, perda da sensibilidade da proteção, abertura inadequada de fusíveis e religamentos automáticos fora de sincronismo. Portanto, este trabalho avalia o impacto da geração distribuída (GD) sobre o sistema de proteção de sobrecorrente de uma rede de distribuição operando ilhada. A ideia principal é dividir a rede em regiões delimitadas pelos dispositivos de proteção existentes, para em seguida, adequá-los à nova situação operacional, certificando se os ajustes propostos atendem ao comportamento síncrono e estável do sistema de geração por meio de uma análise de estabilidade transitória. Propõe-se então um conjunto de procedimentos para tomada de ações que permitam readequar o sistema de proteção de sobrecorrente existente à operação ilhada. Os resultados obtidos demonstram que a inibição do religamento automático e da curva de atuação instantânea acrescida de reajustes nas curvas temporizadas dos relés e religadores, melhoraram a coordenação e seletividade da rede operando ilhada. / The growing number of distributed generators connected to electricity distribution networks is a reality of electrical systems throughout the world. Although the current policy is to disconnect the distributed generators from the electric power system (EPS) in the event of loss of mains, as required by main national and international technical guides, the module 3 of the Procedures for Electric Power Distribution in the Electric National System (PRODIST) shows itself in favor of islanded operation, it states that this type of operation can be carried out in agreement between power generation plants and the National Electric System Operator (ONS), allowing achieve larger availability in energy supply. However, to make the islanded operation possible and safe, the intentional islanding must overcome some challenges, among which are those related to the protection system of the distribution network, such as improper coordination of protective devices, loss of protection sensitivity, inadequate opening of fuses and automatic reclosing out of synchronism. Therefore, this work evaluates the impact of distributed generation (DG) on the overcurrent protection system of a distribution network operating islanded. The main idea is to divide the network into regions bounded by existing protection devices, to then adapt them to the new operational situation, making sure that the proposed adjustments meet the synchronous and stable behavior of the generation system by means of a transient stability analysis. Thus, a set of procedures is proposed to indicate actions that allow readjusting the existing overcurrent protection system to the islanded operation. The results demonstrate that the inhibition of automatic restart and of the instantaneous operating curve plus adjustments in time delay curves of relays and reclosers, improved the coordination and selectivity of the network operating islanded.
12

Avaliação do impacto da geração distribuída sobre o sistema de proteção de sobrecorrente de uma rede de distribuição operando em ilhamento intencional / Impact assessment of the distributed generation on the overcurrent protection system of a distribution network operating in intentional islanding

Sguaçabia, Robson Roberto 26 March 2015 (has links)
O crescente número de geradores distribuídos conectados em redes de distribuição de energia elétrica é uma realidade dos sistemas elétricos de todo o mundo. Embora a política atual seja desconectar os geradores distribuídos do sistema elétrico de potência (SEP) caso ocorra uma falha na rede da concessionária, conforme preconizam os principais guias técnicos nacionais e internacionais, o módulo 3 dos Procedimentos de Distribuição de Energia Elétrica no Sistema Elétrico Nacional (PRODIST) mostra-se favorável à operação ilhada, pois afirma que este tipo de operação pode ser realizado em comum acordo entre as centrais geradoras de energia e o Operador Nacional do Sistema Elétrico (ONS), permitindo alcançar uma maior disponibilidade no fornecimento de energia. No entanto, para que a operação ilhada seja possível e possa ser praticada de forma segura, o ilhamento intencional precisa superar alguns desafios, dentre os quais estão aqueles relacionados ao sistema de proteção da rede de distribuição, tais como: coordenação indevida de dispositivos de proteção, perda da sensibilidade da proteção, abertura inadequada de fusíveis e religamentos automáticos fora de sincronismo. Portanto, este trabalho avalia o impacto da geração distribuída (GD) sobre o sistema de proteção de sobrecorrente de uma rede de distribuição operando ilhada. A ideia principal é dividir a rede em regiões delimitadas pelos dispositivos de proteção existentes, para em seguida, adequá-los à nova situação operacional, certificando se os ajustes propostos atendem ao comportamento síncrono e estável do sistema de geração por meio de uma análise de estabilidade transitória. Propõe-se então um conjunto de procedimentos para tomada de ações que permitam readequar o sistema de proteção de sobrecorrente existente à operação ilhada. Os resultados obtidos demonstram que a inibição do religamento automático e da curva de atuação instantânea acrescida de reajustes nas curvas temporizadas dos relés e religadores, melhoraram a coordenação e seletividade da rede operando ilhada. / The growing number of distributed generators connected to electricity distribution networks is a reality of electrical systems throughout the world. Although the current policy is to disconnect the distributed generators from the electric power system (EPS) in the event of loss of mains, as required by main national and international technical guides, the module 3 of the Procedures for Electric Power Distribution in the Electric National System (PRODIST) shows itself in favor of islanded operation, it states that this type of operation can be carried out in agreement between power generation plants and the National Electric System Operator (ONS), allowing achieve larger availability in energy supply. However, to make the islanded operation possible and safe, the intentional islanding must overcome some challenges, among which are those related to the protection system of the distribution network, such as improper coordination of protective devices, loss of protection sensitivity, inadequate opening of fuses and automatic reclosing out of synchronism. Therefore, this work evaluates the impact of distributed generation (DG) on the overcurrent protection system of a distribution network operating islanded. The main idea is to divide the network into regions bounded by existing protection devices, to then adapt them to the new operational situation, making sure that the proposed adjustments meet the synchronous and stable behavior of the generation system by means of a transient stability analysis. Thus, a set of procedures is proposed to indicate actions that allow readjusting the existing overcurrent protection system to the islanded operation. The results demonstrate that the inhibition of automatic restart and of the instantaneous operating curve plus adjustments in time delay curves of relays and reclosers, improved the coordination and selectivity of the network operating islanded.
13

Mitigação de variações de tensão causadas pela proteção anti-ilhamento de geradores distribuídos via controle de taps de reguladores de tensão / Mitigating voltage variations caused by the anti-islanding protection of distributed generator via voltage regulator tap control

Lima, Daniel Ferreira 04 August 2017 (has links)
A conexão de geradores distribuídos em sistemas de distribuição deve ser cuidadosamente avaliada para que os mesmos auxiliem efetivamente na melhoria do desempenho das redes elétricas, buscando reduzir ou eliminar eventuais situações que causem a degradação da qualidade da energia elétrica fornecida aos consumidores, entre outros aspectos. Neste contexto, existem vários trabalhos que analisam a influência da conexão de geradores distribuídos no perfil de tensão da rede elétrica, frequência, desequilíbrio de fases e distorção harmônica. No entanto, há poucos trabalhos analisando os efeitos da desconexão de geradores distribuídos na qualidade da energia fornecida aos consumidores. Uma vez operando em paralelo com a rede de distribuição, esses geradores influenciam o perfil de tensão e o comportamento dos dispositivos reguladores de tensão. Como consequência, sua desconexão pode provocar variações de tensão intensas causando danos ou mau funcionamento às cargas. A desconexão pode ser repentina ou devido à atuação da proteção anti-ilhamento, seguida dos procedimentos de religamento automático do alimentador, se houver. Visando estudar este problema, o qual tende a se tornar uma nova preocupação das concessionárias de energia elétrica, e no intuito de minimizar e/ou eliminar os possíveis efeitos negativos dessas variações de tensão, esta pesquisa propõe o desenvolvimento de um método de controle dos taps dos reguladores de tensão. Neste método, o controle dos taps foi modelado como um problema de otimização, minimizando as violações de tensão mencionadas anteriormente e também a quantidade de operações dos reguladores de tensão ao longo de um dia típico. A otimização foi solucionada com um Algoritmo Genético e os resultados obtidos indicaram que é possível minimizar as variações de tensão usando a curva de carga do sistema para planejar a operação dos reguladores de tensão. / The connection of distributed generators in an electric power system should be evaluated carefully to ensure that they effectively assist in improving the performance of electrical networks, reducing or eliminating any situations that cause degradation of the power quality of the consumers, and other issues. In this context, there are several studies that analyze the influence of generators connected to distribution systems and how they affect the frequency, cause variations in voltage magnitude, voltage unbalance and harmonic distortion. However, there are a few studies analyzing the effects that the disconnection of distributed generators induces to the power quality of consumers. Once operating in parallel with the distribution network, these generators have an effect on voltage variations and voltage regulator devices. As a result, disconnection can cause severe voltage variations causing damage or malfunction to the loads. The disconnection may be sudden or due to the action of anti-islanding protection, followed by the procedure to reconnect the substation, if it is possible. In order to study this problem, which tends to become a new power quality concern for electric utilities, and in order to minimize and / or eliminate the possible side effects of the voltage variations, this research proposes the development of a control method of voltage regulators\' taps. In this method, the control of taps was modeled as an optimization problem which aimed to minimize these voltage variations aforementioned and also the amount of voltage regulator operations over a typical day. The optimization was solved by a Genetic Algorithm and the results obtained demonstrate that it is possible to minimize the voltage variation by using the system load curve to plan the operation of voltage regulators.
14

Estudo sobre a interação de métodos anti-ilhamento para sistemas fotovoltaicos conectados à rede de distribuição de baixa tensão com múltiplos inversores. / Study about the interation of anti-islanding methods for photovoltaic systems connected to the low voltage distribution grid with multiple inverters.

Silva, Humberto Trindade da 30 March 2016 (has links)
Este trabalho estuda a interação entre os métodos anti-ilhamento aplicados em sistemas fotovoltaicos residenciais, operando simultaneamente em uma rede de distribuição de baixa tensão. Os sistemas fotovoltaicos em geral interagem entre si, com a rede de distribuição da concessionária e com outras fontes de geração distribuída. Uma consequência importante dessa interação é a ocorrência do ilhamento, que acontece quando as fontes de geração distribuída fornecem energia ao sistema elétrico de potência mesmo quando esta se encontra eletricamente isolada do sistema elétrico principal. A função anti-ilhamento é uma proteção extremamente importante, devendo estar presente em todos os sistemas de geração distribuída. Atualmente, são encontradas diversas técnicas na literatura. Muitas delas oferecem proteção adequada quando um inversor está conectado à linha de distribuição, mas podem falhar quando dois ou mais funcionam simultaneamente, conectados juntos ou próximos entre si. Dois destes métodos são analisados detalhadamente nesse estudo, avaliados em uma rede de distribuição residencial de baixa tensão. Os resultados obtidos mostram que a influência de um método sobre o outro é dependente da predominância de cada um deles dentro do sistema elétrico. Contudo, nas condições analisadas o ilhamento foi detectado dentro do limite máximo estabelecido pelas normas pertinentes. / This work studies the interaction between islanding detection methods applied in residential photovoltaic systems, operating simultaneously in a low voltage distribution network. Photovoltaic systems, in general, interact with themselves, with the utility grid and other distributed generation sources. An important consequence of this interaction is the islanding occurrence, which happens when distributed generation sources supply energy to the electrical power system even when it is electrically isolated from the main electrical system. The anti-islanding function is an extremely important protection, and should be present in all distributed generation systems. Actually, many techniques are found in the literature. Most of them provide suitable protection when one inverter is connected to the distribution line, but can fail when two or more work simultaneously, connected at the same point or close to each other. Two of these methods are analyzed in detail in this study and evaluated in a residential low voltage distribution line. The obtained results show that the influence of a method over another one is dependent of the predominance of each one within the electrical system. However, in the analyzed condition the islanding was detected within the maximum allowed time established by applicable rules.
15

Mitigação de variações de tensão causadas pela proteção anti-ilhamento de geradores distribuídos via controle de taps de reguladores de tensão / Mitigating voltage variations caused by the anti-islanding protection of distributed generator via voltage regulator tap control

Daniel Ferreira Lima 04 August 2017 (has links)
A conexão de geradores distribuídos em sistemas de distribuição deve ser cuidadosamente avaliada para que os mesmos auxiliem efetivamente na melhoria do desempenho das redes elétricas, buscando reduzir ou eliminar eventuais situações que causem a degradação da qualidade da energia elétrica fornecida aos consumidores, entre outros aspectos. Neste contexto, existem vários trabalhos que analisam a influência da conexão de geradores distribuídos no perfil de tensão da rede elétrica, frequência, desequilíbrio de fases e distorção harmônica. No entanto, há poucos trabalhos analisando os efeitos da desconexão de geradores distribuídos na qualidade da energia fornecida aos consumidores. Uma vez operando em paralelo com a rede de distribuição, esses geradores influenciam o perfil de tensão e o comportamento dos dispositivos reguladores de tensão. Como consequência, sua desconexão pode provocar variações de tensão intensas causando danos ou mau funcionamento às cargas. A desconexão pode ser repentina ou devido à atuação da proteção anti-ilhamento, seguida dos procedimentos de religamento automático do alimentador, se houver. Visando estudar este problema, o qual tende a se tornar uma nova preocupação das concessionárias de energia elétrica, e no intuito de minimizar e/ou eliminar os possíveis efeitos negativos dessas variações de tensão, esta pesquisa propõe o desenvolvimento de um método de controle dos taps dos reguladores de tensão. Neste método, o controle dos taps foi modelado como um problema de otimização, minimizando as violações de tensão mencionadas anteriormente e também a quantidade de operações dos reguladores de tensão ao longo de um dia típico. A otimização foi solucionada com um Algoritmo Genético e os resultados obtidos indicaram que é possível minimizar as variações de tensão usando a curva de carga do sistema para planejar a operação dos reguladores de tensão. / The connection of distributed generators in an electric power system should be evaluated carefully to ensure that they effectively assist in improving the performance of electrical networks, reducing or eliminating any situations that cause degradation of the power quality of the consumers, and other issues. In this context, there are several studies that analyze the influence of generators connected to distribution systems and how they affect the frequency, cause variations in voltage magnitude, voltage unbalance and harmonic distortion. However, there are a few studies analyzing the effects that the disconnection of distributed generators induces to the power quality of consumers. Once operating in parallel with the distribution network, these generators have an effect on voltage variations and voltage regulator devices. As a result, disconnection can cause severe voltage variations causing damage or malfunction to the loads. The disconnection may be sudden or due to the action of anti-islanding protection, followed by the procedure to reconnect the substation, if it is possible. In order to study this problem, which tends to become a new power quality concern for electric utilities, and in order to minimize and / or eliminate the possible side effects of the voltage variations, this research proposes the development of a control method of voltage regulators\' taps. In this method, the control of taps was modeled as an optimization problem which aimed to minimize these voltage variations aforementioned and also the amount of voltage regulator operations over a typical day. The optimization was solved by a Genetic Algorithm and the results obtained demonstrate that it is possible to minimize the voltage variation by using the system load curve to plan the operation of voltage regulators.
16

Estudo sobre a interação de métodos anti-ilhamento para sistemas fotovoltaicos conectados à rede de distribuição de baixa tensão com múltiplos inversores. / Study about the interation of anti-islanding methods for photovoltaic systems connected to the low voltage distribution grid with multiple inverters.

Humberto Trindade da Silva 30 March 2016 (has links)
Este trabalho estuda a interação entre os métodos anti-ilhamento aplicados em sistemas fotovoltaicos residenciais, operando simultaneamente em uma rede de distribuição de baixa tensão. Os sistemas fotovoltaicos em geral interagem entre si, com a rede de distribuição da concessionária e com outras fontes de geração distribuída. Uma consequência importante dessa interação é a ocorrência do ilhamento, que acontece quando as fontes de geração distribuída fornecem energia ao sistema elétrico de potência mesmo quando esta se encontra eletricamente isolada do sistema elétrico principal. A função anti-ilhamento é uma proteção extremamente importante, devendo estar presente em todos os sistemas de geração distribuída. Atualmente, são encontradas diversas técnicas na literatura. Muitas delas oferecem proteção adequada quando um inversor está conectado à linha de distribuição, mas podem falhar quando dois ou mais funcionam simultaneamente, conectados juntos ou próximos entre si. Dois destes métodos são analisados detalhadamente nesse estudo, avaliados em uma rede de distribuição residencial de baixa tensão. Os resultados obtidos mostram que a influência de um método sobre o outro é dependente da predominância de cada um deles dentro do sistema elétrico. Contudo, nas condições analisadas o ilhamento foi detectado dentro do limite máximo estabelecido pelas normas pertinentes. / This work studies the interaction between islanding detection methods applied in residential photovoltaic systems, operating simultaneously in a low voltage distribution network. Photovoltaic systems, in general, interact with themselves, with the utility grid and other distributed generation sources. An important consequence of this interaction is the islanding occurrence, which happens when distributed generation sources supply energy to the electrical power system even when it is electrically isolated from the main electrical system. The anti-islanding function is an extremely important protection, and should be present in all distributed generation systems. Actually, many techniques are found in the literature. Most of them provide suitable protection when one inverter is connected to the distribution line, but can fail when two or more work simultaneously, connected at the same point or close to each other. Two of these methods are analyzed in detail in this study and evaluated in a residential low voltage distribution line. The obtained results show that the influence of a method over another one is dependent of the predominance of each one within the electrical system. However, in the analyzed condition the islanding was detected within the maximum allowed time established by applicable rules.
17

Metodologia de análise de variações de tensão causadas pela proteção anti-ilhamento de geradores síncronos distribuídos / Methodology for analysis of voltage variations caused by anti-island protection of distributed synchronous generators

Nascimento, Klaus Vieira do 17 June 2013 (has links)
Nos últimos anos, fatores como a reestruturação do setor de energia elétrica, a necessidade de aproveitamento de diferentes fontes primárias de energia, dificuldades na construção de grandes unidades geradoras e linhas de transmissão causadas por normas de proteção ambiental têm provocado o aumento considerável do interesse por geração distribuída. O conceito de geração distribuída tornou-se muito interessante, entretanto, sua aplicação pode provocar problemas de qualidade de energia elétrica, caso sua influência não seja devidamente estudada. Neste contexto, este documento caracteriza as variações de tensão causadas pela atuação da proteção anti-ilhamento de geradores síncronos distribuídos. Este problema pode ser considerado uma nova abordagem sobre os impactos dos geradores distribuídos na qualidade da energia elétrica, visto que as causas das variações de tensão são tipicamente relacionadas às tomadas ou alívios de grandes blocos carga, partidas de motores de indução, curtos-circuitos, desligamentos de linhas etc. Para estudar o problema, inicialmente foi feito um estudo sobre normatização técnica da área com um apanhado dos guias de diversas concessionárias. Posteriormente, simulações computacionais utilizando o programa SimPowerSystems e um sistema teste foram utilizados para que análises estáticas e dinâmicas do problema fossem feitas no intuito de investigar a natureza das variações de tensão e os fatores que influenciam suas magnitudes e durações. Índices para avaliar as variações de tensão foram criados, e um método para obtenção dos mesmos foi proposto. Tal método utiliza apenas ferramentas de análise estática (fluxo de carga) para a obtenção dos índices, evitando o uso de ferramentas dinâmicas (domínio do tempo) reduzindo o custo computacional e financeiro para análise do problema. Em seguida, o mesmo foi aplicado a um sistema que simula uma rede de distribuição real propondo-se a inserção de bancos de capacitores como medida mitigatória para o problema estudado neste trabalho. / In recent years, factors such as the restructuring of the electricity sector, the necessity to use different primary energy sources as a way to diversify sources of energy, barriers in the construction of large generating units and transmission lines caused by environmental protection standards, as well as technological advances in the generation of electricity, have caused a considerable increase in the interest for distributed generation. The concept of distributed generation has become very interesting; however, its application can result in poor power quality, if its influence is not well studied. In this context, this document characterizes voltage variations caused by the action of anti-islanding protection of distributed synchronous generators. This problem can be considered a new approach on the impact of distributed generators in power quality, since the cause of voltage variations are typically related load switching, induction motors start-up, short circuits, lines disconnection, etc. To investigate the problem, initially a study was carried out on technical standardization in the area with an overview of various utilities guides. Later, computer simulations using the SimPowerSystems software and a test system were employed for static and dynamic analysis of the problem, aiming at investigating the nature of voltage variations and the main factors that influence their magnitudes and durations. Indices to assess the voltage variations were created, and a method for obtaining them was proposed. This method uses only static approach tools (power flow calculations) to obtain the indices, avoiding the use of dynamic tools (time-domain simulations) and reducing computational and financial costs to analyses the problem. The proposed method was applied to a larger system and the insertion of capacitors bank was proposed as mitigating solution for the problem studied in this work.
18

Metodologias de ajuste das proteções anti-ilhamento de geradores distribuídos considerando múltiplos eventos / Methodology to adjust distributed generation anti-islanding protections based on multiple events

Motter, Daniel 16 November 2017 (has links)
Os geradores distribuídos em sistemas de distribuição de energia elétrica devem ser desconectados em eventos de ilhamento, que ocorrem quando parte da rede elétrica torna-se eletricamente isolada da concessionária e o subsistema isolado continua a ser energizado pela geração distribuída. A proteção anti-ilhamento deve detectar tal condição operativa, porém pode não atuar em condições de pequenos desbalanços entre carga e geração, ou atuar incorretamente para eventos de outra natureza. Assim, um ajuste adequado dessa proteção deve desconectar o gerador rapidamente quando detecta o ilhamento e, simultaneamente, deve ser imune a eventos como curtos-circuitos e chaveamentos de carga, por exemplo. Esta pode ser uma tarefa muito difícil face às variações de carga e diferentes eventos de não ilhamento que podem ocorrer no sistema de distribuição. Portanto, nesta tese são propostas metodologias de ajuste das funções de proteção anti-ilhamento de sub/sobrefrequência, taxa de variação de frequência, salto de vetor e sub/sobretensão, que são técnicas convencionalmente utilizadas para a detecção de ilhamento de geração distribuída. O objetivo das metodologias é maximizar a detecção de ilhamento e minimizar a atuação incorreta, e são considerados cenários com múltiplos geradores distribuídos de diferentes tecnologias. Inicialmente, são explorados os principais fatores que afetam as proteções, tais como distribuição das cargas, fator de potência e desequilíbrio das cargas. Esta análise permite identificar os casos mais difíceis de detecção de ilhamento. Como segunda contribuição, foi proposta a metodologia de análise gráfica denominada Mapa de Ajustes, cuja eficácia foi comprovada por meio de casos de teste, mostrando ser capaz de melhorar a sensibilidade da proteção anti-ilhamento e minimizar atuação incorreta. Na sequência, é apresentado um método automático para ajuste e bloqueio de tensão e outro baseado em proteção adaptativa para ajuste das funções de proteção. Ambos são baseados na metodologia de mapa de ajustes. Os resultados indicam que é possível melhorar a detecção de ilhamento e diminuir a atuação incorreta quando utilizadas as metodologias propostas. / Distributed generators in power distribution systems must be disconnected after an islanding event, which occurs when part of the power grid becomes electrically isolated from the utility and the isolated subsystem continues to be energized by the distributed generation. The antiislanding protection has to detect such operating condition, which may fail for critical loading conditions, or operate incorrectly for events of other nature than islanding. Therefore, an appropriate protection setting should quickly disconnect the generator when an islanding event is detected, and simultaneously, must be immune to events such as short circuits and load switches. This can be a very difficult task due to load variations and different nonislanding events that may occur in the distribution system. Therefore, in this thesis is proposed methodologies to adjust the anti-islanding protection functions of under/overfrequency, rate of change of frequency, vector surge and under/overvoltage, which are techniques conventionally used for islanding detection of distributed generation. The methodologies goals are to maximize the performance of the anti-islanding protection and minimize the incorrect operation to events of other nature, and scenarios with multiple distributed generators of different technologies are considered. At first, the main factors that affect the frequency and voltage-based protection will be explored, such as load distribution, power factor and unbalanced loads. This analysis aims to identify the most critical cases of islanding detection. The second contribution of this thesis is the Setting Map methodology, which is a graphical analysis whose effectiveness has been proved by case studies, showing to be able to improve the sensitivity of anti-islanding protection, minimizing the chances of incorrect operation. In sequence, is presented an automatic method to adjust the protection functions and voltage blocking and other based on adaptive protection. Both methods are based on the Setting Map methodology. The results indicate that it is possible to improve the islanding detection and reduce the incorrect actuation when it is used the proposed methodologies.
19

Análise de requisitos técnicos para ilhamento intencional de geradores síncronos distribuídos / Analysis of technical requirements for intentional islanding of distributed synchronous generators

Lima, Rogério Lúcio 09 August 2013 (has links)
Havendo qualquer distúrbio em um determinado sistema de distribuição de energia elétrica na presença de geradores distribuídos (GDs), é procedimento habitual exigido pelas concessionárias a desconexão destes na intenção de evitar a formação de um sistema ilhado eletricamente sustentado. Este procedimento tem como objetivo evitar maiores danos tanto ao sistema elétrico como um todo, principalmente ao próprio gerador distribuído, bem como às pessoas envolvidas na manutenção desse sistema. Entretanto, esse fato diminui consideravelmente as contribuições do conceito de geração distribuída à melhoria da qualidade dos serviços de fornecimento de energia elétrica por parte das concessionárias. Neste contexto, este trabalho possui como objetivo analisar os requisitos técnicos necessários para viabilizar a operação ilhada dos geradores distribuídos. Sabendo que a maioria das cargas presentes em um sistema de distribuição é dependente dos níveis de tensão e frequência da energia de suprimento, a análise e o monitoramento dessas grandezas antes e durante o ilhamento deverão ocorrer de forma que não se perca a estabilidade da rede ilhada. Para isto, devem ser avaliadas alterações nos métodos de operação e controle dos geradores distribuídos, de maneira a atender os requisitos técnicos necessários para manter a tensão e a frequência dentro dos parâmetros de qualidade de energia elétrica. Foram propostos quatro índices de desempenho para avaliar a qualidade da energia elétrica no sistema ilhado. Os resultados obtidos demonstram a necessidade de efetuar ações corretivas eficientes para manter o sistema elétrico ilhado operando dentro dos padrões aceitáveis de qualidade de energia elétrica. Foram investigadas soluções potenciais e viáveis para garantir a operação da ilha estável e com qualidade da energia elétrica. Além disso, observou-se que cargas dependentes da tensão podem influenciar significativamente a capacidade do GD em formar de ilhas estáveis. / If disturbances occur in a power distribution systems in the presence of distributed generators (DGs), a common practice required by utilities is to disconnect such generators, aiming at avoiding a self-sustained energized island. This procedure is required on order to prevent damage to the whole distribution system, mainly the DG, and to the utility maintenance personnel, as well. However, this requirement may decrease the possible contributions of the distributed generation concepts to the quality of the power supply. In this context, this work aims at analyzing the technical requirements related to make DGs islanded operation feasible. Since most of the loads are dependent on the supply voltage and frequency, the analysis and monitoring of such quantities before and after an islanding event should occur in such a way that the stability of the energized island is granted. To reach such a goal, changes in the DG control modes must be assessed, so that the technical requirements necessary to keep voltage and frequency within statutory limits are fulfilled. Four performance indices have been proposed to assess the power quality in the islanded system. The results have shown the need to perform efficient corrective actions to ensure reliable islanded operation. Moreover, it was observed that voltage-dependent loads may influence the DG capability to sustain stable islands.
20

Análise da influência de diferentes tipos de cargas no desempenho da proteção anti-ilhamento de geradores distribuídos / Analysis of influence of different types of loads on the performance of anti-islanding protection of distributed generators

Carvalho, Marcelo Moreira de 04 September 2014 (has links)
A conexão de geradores distribuídos nas redes de subtransmissão e de distribuição de energia elétrica se mostra cada vez mais crescente devido aos inúmeros benefícios técnicos e econômicos alcançados com essa tecnologia. No entanto, há importantes implicações técnicas que precisam ser analisadas antes que um gerador distribuído seja conectado em paralelo ao sistema elétrico. Um aspecto a ser analisado, e que é comum entre as concessionárias de energia elétrica é a adequação da proteção anti-ilhamento, a qual tem a função de detectar essa condição e, automaticamente, desconectar os geradores distribuídos, dentro de um tempo pré-determinado, e assim mantê-los até que o fornecimento de energia seja restabelecido. Neste contexto, este trabalho analisará o desempenho dos relés de proteção anti-ilhamento em face de diferentes tipos de cargas que acabam afetando o tempo de detecção do ilhamento. Com isso, pretende-se obter subsídios para que os ajustes desses relés sejam calculados de forma eficiente. Os relés estudados são o relé de sub/sobrefrequência e o relé de taxa de variação da frequência, e o gerador distribuído é do tipo síncrono equipado com controle de tensão. As análises mostraram que no instante em que ocorre um ilhamento os fatores que mais influenciam no desempenho dos relés de proteção anti-ilhamento são as condições de carga e geração, tempo de detecção estabelecido, tipo do relé adotado, ajuste do mesmo e modelo de carga utilizado. / The connection of distributed generators to power subtransmission and distribution networks has been increasing recently due to the technical and economic benefits that such technology can provide. However, there are important technical issues that need to be carefully analyzed before a distributed generator is connected to electrical systems. One issue to be analyzed, which is common sense among utility companies, is the anti-islanding protection, whose main goal is to detect unintentional islanding and, automatically, disconnect the distributed generators within a required time-interval. In this context, this work will analyze the performance of anti-islanding protection relays in face of different load types. With this study, one intend to get support for adjusting these relays efficiently. The relays studied in this work are the under/over frequency and the rate of change of frequency relays, and the distributed generator is a synchronous machine equipped with an automatic voltage regulator. The analyzes showed that the moment a islanding occurs the most important factors influencing the performance of relays anti-islanding protection are the conditions of load and generation, detection time set, type and relay setting adopted and load model.