• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • Tagged with
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Analise do desempenho luminoso de sistemas de iluminação zenital em função da distribuição de iluminancias

Cabus, Ricardo Carvalho January 1997 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnologico / Made available in DSpace on 2012-10-17T01:49:37Z (GMT). No. of bitstreams: 0Bitstream added on 2016-01-08T22:39:26Z : No. of bitstreams: 1 108167.pdf: 40486234 bytes, checksum: 53468004d13f28aa227411adbf424186 (MD5) / A partir do uso de simulações computacionais, através do programa Lumen Micro, este trabalho analisa a distribuição de iluminâncias em um conjunto de ambientes com variados sistemas de iluminação zenital. A análise comparativa entre os resultados obtidos gera uma série de tabelas e gráficos, que relacionam a distribuição de iluminâncias com a refletividade das superfícies internas, a forma do recinto, o perímetro e a quantidade de aberturas. Simultaneamente, é feito o mapeamento dos ambientes em função da distribuição de iluminâncias, com vistas à delimitação de áreas onde haja iluminação natural suficiente, em excesso ou em falta.
2

Estudo comparativo de sistemas de iluminação artificial com diferentes luminárias considerando a disponibilidade de luz natural

Moraes, Letícia Niero January 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Arquitetura e Urbanismo / Made available in DSpace on 2013-06-25T22:16:27Z (GMT). No. of bitstreams: 1 308888.pdf: 8913252 bytes, checksum: cab519e39f7132cae06b101d7bd62b15 (MD5) / O aproveitamento da iluminação natural é indicado como um fator primordial na economia de energia das edificações, já que possibilita a redução do uso dos sistemas de iluminação artificial através de sistemas de controle. No entanto, a eficiência dos sistemas está associada também às características técnicas e ao desempenho de um conjunto de elementos do sistema de iluminação artificial. Este trabalho busca investigar os critérios e o impacto de projeto de sistemas de iluminação com diferentes luminárias considerando a disponibilidade de luz natural. A metodologia adotada é baseada na avaliação do desempenho luminoso, como uniformidade, níveis e distribuição de iluminâncias e consumo de energia de sistemas de iluminação artificial, através de simulação computacional. São estimadas disponibilidades de iluminação natural para dois modelos de escritório de planta livre, localizados na cidade de Florianópolis/SC. As análises de aproveitamento da luz natural são utilizadas para estimar o consumo energético para diferentes propostas de sistemas de iluminação artificial, através da divisão de circuitos de acionamento. Os sistemas de iluminação artificial propostos são diferenciados pelas fotometrias e disposições das luminárias. Para cada caso, são elaboradas reformulações dos sistemas, com o objetivo de verificar a influência de critérios como espaçamento, orientação e distribuição das luminárias no comportamento da iluminação, assim como no consumo de energia. Concluiu-se que a avaliação baseada em apenas um parâmetro não permitiu a definição da qualidade do projeto. Os resultados mostram que cada sistema proposto possui diferenças significativas quanto à distribuição da iluminação, assim como no consumo de energia da instalação. A consideração da iluminação natural não influenciou significativamente no que diz respeito às análises de qualidade da iluminação, mas nas análises de consumo constata-se que este está diretamente relacionado com a geometria do ambiente, chegando a economias de até 46%. Uma das principais contribuições deste estudo é obtenção de critérios que conduzam a um melhor dimensionamento do sistema de iluminação artificial. / The use of daylight is indicated as a primary factor in energy savings of buildings, since it can reduce the use of electric lighting through control systems. However, the efficiency of systems is also associated with technical characteristics and performance of various elements of the artificial lighting systems. This paper seeks to investigate the impact of design criteria and lighting systems with different fixtures considering the availability of daylight. The methodology is based on evaluating the performance of light, such as distribution of illuminance and estimated energy consumption of artificial lighting systems through computer simulation. Are estimated daylight availability for two models of open plan office, located in Florianópolis / SC. Analyses of daylight are used to measure the energy consumption for different proposals for lighting systems, by dividing the drive circuits. The systems are differentiated by photometry and disposal of the luminaires. For each case, artificial lighting system reformulations are made in order to verify the influence of criteria such as spacing, orientation and distribution of lighting fixtures in behavior, as well as in energy consumption. It was concluded that the evaluation based on only one parameter is not allowed the definition of design quality. The results show that each proposed system has significant differences in the distribution of illumination, as well as in power consumption of the installation. The consideration of daylight does not influence significantly in relation to the analysis of lighting quality, but the analysis of consumption it is clear that this is directly related to the geometry of the environment, reaching up to 46% savings. A major contribution of this study is to obtain criteria that lead to a better design of the artificial lighting system.
3

Análise das condições de iluminação em edificação de escritórios

Noguchi, Mika Yada January 2003 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Civil. / Made available in DSpace on 2012-10-20T13:54:47Z (GMT). No. of bitstreams: 1 206651.pdf: 6065626 bytes, checksum: e4ad14395aea34a2f71c711cc621ce70 (MD5) / O ambiente luminoso possui relação com a interpretação de mensagens visuais. O conforto visual deve ser entendido como resultado da recepção clara das mensagens visuais do ambiente. Tradicionalmente, têm-se associado apenas os níveis de iluminância e pouco tem sido enfatizada a necessidade de promover o ambiente de trabalho a favor do usuário e em benefício da produtividade. A presente pesquisa tem como finalidade analisar as condições de iluminação em edificação de escritórios: um estudo de caso no paço municipal de Maringá - PR. Foi realizada avaliação em duas salas do quarto piso da edificação, especificamente na sala de engenharia e sala de controle urbano da Secretaria de Desenvolvimento Urbano, Planejamento e Habitação. Em ambas, verificou-se que a iluminação é insuficiente para desempenho das tarefas específicas. Procedeu-se a experimentos na distribuição de iluminância nos planos horizontais e verticais através de normas e projetos de normas e verificou-se a interferência da luz do sol especificamente na sala de engenharia, ofuscamento indireto nos planos das tarefas e avaliou-se a freqüência de utilização dos interruptores. Os ambientes escolhidos apresentaram diminuição nos níveis de iluminância nos fundos das salas, mesmo suplementadas pela iluminação artificial. Iluminâncias médias encontradas na sala de controle urbano de 400lux na condição de iluminação conjugada, não foi elemento comprometedor para desconforto visual, podendo os usuários desenvolver normalmente suas atividades. A vegetação arbórea próxima às janelas participou na caracterização dos níveis de iluminância no interior das salas. Ofuscamento direto e indireto foi uma ocorrência que contribuiu significativamente para o desconforto visual. Os resultados mostraram que as informações colocadas pelos usuários apresentaram a real situação das condições dos ambientes.
4

Melhoria da eficiência luminosa: estudo de caso do Centro Federal de Educação Tecnológica do Paraná - CEFET-PR - Unidade de Curitiba

Cervelin, Severino January 2002 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia de Produção. / Made available in DSpace on 2012-10-19T15:04:32Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-26T01:06:01Z : No. of bitstreams: 1 195599.pdf: 14854586 bytes, checksum: 75f3e6376f7f9247b8070749c0124809 (MD5)

Page generated in 0.0795 seconds