• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 15
  • 15
  • 5
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Validierung einer neuen Software für halbautomatische Volumetrie – ist diese besser als manuelle Messungen?

Noschinski, Leonie 22 September 2016 (has links) (PDF)
This study compared a manual program for liver volumetry with a semiautomated software. The hypothesis was that the software would be faster, more accurate and less dependent on the evaluator’s experience. Materials and Methods: Ten patients undergoing hemihepatectomy were included into this IRB approved study after written informed consent. All patients underwent a preoperative abdominal CTScan, which was used for whole liver volumetry and volume prediction for the liver part to be resected. Two different softwares were used: 1) manual method: borders of the liver had to be defined per slice by the user; 2) semiautomated software: automatic identification of liver volume with manual assistance for definition of Couinaud-segments. Measurements were done by six observers with different experience levels. Water displacement volumetry immediately after partial liver resection served as gold standard. The resected part was examined with a CT-scan after displacement volumetry. Results: Volumetry of the resected liver scan showed excellent correlations to water displacement volumetry (manual: ρ=0.997; semiautomated software: ρ=0.995). Difference between the predicted volume and the real volume was significantly smaller with the semiautomated software than with the manual method (33 % vs. 57 %, p=0.002). The semiautomated software was almost four times faster for volumetry of the whole liver. Conclusion: Both methods for liver volumetry give an estimated liver volume close to the real one. The tested semiautomated software is faster, more accurate in predicting the volume of the resected liver part, gives more reproducible results and is less dependent on the user’s experience. / Ziel dieser Studie war es, eine manuelle Methode zur Lebervolumetrie mit einer halbautomatischen Software zu vergleichen. Die zu prüfende Hypothese war eine Überlegenheit der halbautomatischen Software hinsichtlich Schnelligkeit, Genauigkeit und Unabhängigkeit von der Erfahrung des Auswerters. Material und Methoden: Die Studie wurde von der Ethikkommission geprüft und es lagen Einverständniserklärungen aller Patienten vor. In die Studie wurden zehn Patienten eingeschlossen, die eine Hemihepatektomie erhielten. Es wurde präoperativ ein CT-Scan angefertigt, der sowohl für die Volumetrie der gesamten Leber als auch zur Bestimmung des Resektatvolumens verwendet wurde. Für die Volumetrie wurden zwei verschiedene Programme genutzt: 1) eine manuelle Methode, wobei die Lebergrenzen in jeder Schicht vom Auswerter definiert werden mussten 2) eine halbautomatische Software mit automatischer Erkennung des Lebervolumens und manueller Definition der Lebersegmente nach Coinaud. Die Messungen wurden von sechs Auswertern mit unterschiedlicher Erfahrung vorgenommen. Als Goldstandard diente eine Verdrängungsvolumetrie des Leberresektats, die direkt nach der Resektion im Operationssaal durchgeführt wurde. Anschließend wurde zusätzlich ein CT-Scan des Resektats angefertigt. Ergebnisse: Die Ergebnisse des postoperativen CT-Scans korrelierten hochgradig mit den Ergebnissen der Verdrängungsvolumetrie (manuell: ρ=0.997; halbautomatische Software: ρ=0.995). Mit der halbautomatischen Software fielen die Unterschiede zwischen dem vorhergesagten und dem tatsächlichen Volumen signifikant kleiner aus (33 % vs. 57 %, p=0.002). Zudem lieferte die halbautomatische Software die Volumina der Gesamtleber 3.9mal schneller. Schlussfolgerung: Beide Methoden erlauben eine sehr gute Abschätzung des Lebervolumens. Die getestete halbautomatische Software kann das Lebervolumen jedoch schneller und das Resektatvolumen genauer vorhersagen und ist zusätzlich unabhängiger von der Erfahrung des Auswerters.
12

Exploring Multi-Domain and Multi-Modal Representations for Unsupervised Image-to-Image Translation

Liu, Yahui 20 May 2022 (has links)
Unsupervised image-to-image translation (UNIT) is a challenging task in the image manipulation field, where input images in a visual domain are mapped into another domain with desired visual patterns (also called styles). An ideal direction in this field is to build a model that can map an input image in a domain to multiple target domains and generate diverse outputs in each target domain, which is termed as multi-domain and multi-modal unsupervised image-to-image translation (MMUIT). Recent studies have shown remarkable results in UNIT but they suffer from four main limitations: (1) State-of-the-art UNIT methods are either built from several two-domain mappings that are required to be learned independently or they generate low-diversity results, a phenomenon also known as model collapse. (2) Most of the manipulation is with the assistance of visual maps or digital labels without exploring natural languages, which could be more scalable and flexible in practice. (3) In an MMUIT system, the style latent space is usually disentangled between every two image domains. While interpolations within domains are smooth, interpolations between two different domains often result in unrealistic images with artifacts when interpolating between two randomly sampled style representations from two different domains. Improving the smoothness of the style latent space can lead to gradual interpolations between any two style latent representations even between any two domains. (4) It is expensive to train MMUIT models from scratch at high resolution. Interpreting the latent space of pre-trained unconditional GANs can achieve pretty good image translations, especially high-quality synthesized images (e.g., 1024x1024 resolution). However, few works explore building an MMUIT system with such pre-trained GANs. In this thesis, we focus on these vital issues and propose several techniques for building better MMUIT systems. First, we base on the content-style disentangled framework and propose to fit the style latent space with Gaussian Mixture Models (GMMs). It allows a well-trained network using a shared disentangled style latent space to model multi-domain translations. Meanwhile, we can randomly sample different style representations from a Gaussian component or use a reference image for style transfer. Second, we show how the GMM-modeled latent style space can be combined with a language model (e.g., a simple LSTM network) to manipulate multiple styles by using textual commands. Then, we not only propose easy-to-use constraints to improve the smoothness of the style latent space in MMUIT models, but also design a novel metric to quantitatively evaluate the smoothness of the style latent space. Finally, we build a new model to use pretrained unconditional GANs to do MMUIT tasks.
13

Validierung einer neuen Software für halbautomatische Volumetrie – ist diese besser als manuelle Messungen?

Noschinski, Leonie 19 July 2016 (has links)
This study compared a manual program for liver volumetry with a semiautomated software. The hypothesis was that the software would be faster, more accurate and less dependent on the evaluator’s experience. Materials and Methods: Ten patients undergoing hemihepatectomy were included into this IRB approved study after written informed consent. All patients underwent a preoperative abdominal CTScan, which was used for whole liver volumetry and volume prediction for the liver part to be resected. Two different softwares were used: 1) manual method: borders of the liver had to be defined per slice by the user; 2) semiautomated software: automatic identification of liver volume with manual assistance for definition of Couinaud-segments. Measurements were done by six observers with different experience levels. Water displacement volumetry immediately after partial liver resection served as gold standard. The resected part was examined with a CT-scan after displacement volumetry. Results: Volumetry of the resected liver scan showed excellent correlations to water displacement volumetry (manual: ρ=0.997; semiautomated software: ρ=0.995). Difference between the predicted volume and the real volume was significantly smaller with the semiautomated software than with the manual method (33 % vs. 57 %, p=0.002). The semiautomated software was almost four times faster for volumetry of the whole liver. Conclusion: Both methods for liver volumetry give an estimated liver volume close to the real one. The tested semiautomated software is faster, more accurate in predicting the volume of the resected liver part, gives more reproducible results and is less dependent on the user’s experience. / Ziel dieser Studie war es, eine manuelle Methode zur Lebervolumetrie mit einer halbautomatischen Software zu vergleichen. Die zu prüfende Hypothese war eine Überlegenheit der halbautomatischen Software hinsichtlich Schnelligkeit, Genauigkeit und Unabhängigkeit von der Erfahrung des Auswerters. Material und Methoden: Die Studie wurde von der Ethikkommission geprüft und es lagen Einverständniserklärungen aller Patienten vor. In die Studie wurden zehn Patienten eingeschlossen, die eine Hemihepatektomie erhielten. Es wurde präoperativ ein CT-Scan angefertigt, der sowohl für die Volumetrie der gesamten Leber als auch zur Bestimmung des Resektatvolumens verwendet wurde. Für die Volumetrie wurden zwei verschiedene Programme genutzt: 1) eine manuelle Methode, wobei die Lebergrenzen in jeder Schicht vom Auswerter definiert werden mussten 2) eine halbautomatische Software mit automatischer Erkennung des Lebervolumens und manueller Definition der Lebersegmente nach Coinaud. Die Messungen wurden von sechs Auswertern mit unterschiedlicher Erfahrung vorgenommen. Als Goldstandard diente eine Verdrängungsvolumetrie des Leberresektats, die direkt nach der Resektion im Operationssaal durchgeführt wurde. Anschließend wurde zusätzlich ein CT-Scan des Resektats angefertigt. Ergebnisse: Die Ergebnisse des postoperativen CT-Scans korrelierten hochgradig mit den Ergebnissen der Verdrängungsvolumetrie (manuell: ρ=0.997; halbautomatische Software: ρ=0.995). Mit der halbautomatischen Software fielen die Unterschiede zwischen dem vorhergesagten und dem tatsächlichen Volumen signifikant kleiner aus (33 % vs. 57 %, p=0.002). Zudem lieferte die halbautomatische Software die Volumina der Gesamtleber 3.9mal schneller. Schlussfolgerung: Beide Methoden erlauben eine sehr gute Abschätzung des Lebervolumens. Die getestete halbautomatische Software kann das Lebervolumen jedoch schneller und das Resektatvolumen genauer vorhersagen und ist zusätzlich unabhängiger von der Erfahrung des Auswerters.
14

Text-Driven Fashion Image Manipulation with GANs : A case study in full-body human image manipulation in fashion / Textdriven manipulation av modebilder med GANs : En fallstudie om helkroppsbildsmanipulation av människor inom mode

Dadfar, Reza January 2023 (has links)
Language-based fashion image editing has promising applications in design, sustainability, and art. However, it is considered a challenging problem in computer vision and graphics. The diversity of human poses and the complexity of clothing shapes and textures make the editing problem difficult. Inspired by recent progress in editing face images through manipulating latent representations, such as StyleCLIP and HairCLIP, we apply those methods in editing the images of full-body humans in fashion datasets and evaluate their effectiveness. First, we assess different methodologies to find a latent representation of an image via Generative Adversarial Network (GAN) inversion; then, we apply three image manipulation schemes. Thus, a pre-trained e4e encoder is initially utilized for the inversion process, while the results are compared to a more accurate method, Pivotal Tuning Inversion (PTI). Next, we employ an optimization scheme that uses the Contrastive Language Image Pre-training (CLIP) model to guide the latent representation of an image in the direction of attributes described in the input text. We address the problem of the accuracy and speed of the process by incorporating a mapper network. Finally, we propose an optimized mapper called Text-Driven Garment Editing Mapper (TD-GEM) to achieve high-quality image editing in a disentangled way. Our empirical results show that the proposed method can edit fashion items for changing color and sleeve length. / Språkbaserad bildredigering inom mode har lovande tillämpningar inom design, hållbarhet och konst. Det betraktas dock som ett utmanande problem inom datorseende och grafik. Mångfalden och variationen av mänskliga poser och komplexiteten i klädform och texturer gör redigeringsproblemet svårt. Inspirerade av den senaste utvecklingen inom redigering av ansiktsbilder genom manipulation av latenta representationer, såsom StyleCLIP och HairCLIP, tillämpar vi dessa metoder för att redigera bilderna av fullständiga mänskliga kroppar i mode-dataset och utvärderar deras effektivitet. Först jämför vi olika metoder för att hitta en latent representation av en bild via så kallade Generative Adversarial Network (GAN) inversion; sedan tillämpar vi tre bildmanipulationsscheman. En förtränad (eng: pre-trained) e4e-encoder model används först för inversionsprocessen, medan resultaten jämförs med en mer exakt metod, Pivotal Tuning Inversion (PTI). Därefter använder vi en optimeringmetod som använder Contrastive Language Image Pre-training (CLIP) -modell för att vägleda den latenta representationen av en bild i riktning mot attribut som beskrivs i inmatningstexten. Vi tar upp problemet med noggrannhet och hastigheten i processen genom att integrera en mapper-nätverk. Slutligen föreslår vi en optimerad mapper som kallas TD-GEM för att uppnå högkvalitativ bildredigering på ett lösgjort sätt. Våra empiriska resultat visar att den föreslagna metoden kan redigera modeobjekt för att ändra färg och ärmens längd.
15

An Adversarial Approach to Spliced Forgery Detection and Localization in Satellite Imagery

Emily R Bartusiak (6630773) 11 June 2019 (has links)
The widespread availability of image editing tools and improvements in image processing techniques make image manipulation feasible for the general population. Oftentimes, easy-to-use yet sophisticated image editing tools produce results that contain modifications imperceptible to the human observer. Distribution of forged images can have drastic ramifications, especially when coupled with the speed and vastness of the Internet. Therefore, verifying image integrity poses an immense and important challenge to the digital forensic community. Satellite images specifically can be modified in a number of ways, such as inserting objects into an image to hide existing scenes and structures. In this thesis, we describe the use of a Conditional Generative Adversarial Network (cGAN) to identify the presence of such spliced forgeries within satellite images. Additionally, we identify their locations and shapes. Trained on pristine and falsified images, our method achieves high success on these detection and localization objectives.

Page generated in 0.0951 seconds