21 |
Estudo comparativo do diagnóstico de edema macular secundário a oclusão de ramo da veia central da retina pela biomicroscopia de mácula, angiofluoresceinografia e tomografia de coerência óptica / Comparison of optic coherence tomography, macular biomicroscopy and fluorescein angiography for macular edema secondary to branch retinal vein occlusionAlexandre Grobberio Pinheiro 04 October 2007 (has links)
As Oclusões Venosas da Retina são complicações do sistema vascular retiniano com grande potencial de impacto no sentido da visão. As oclusões Venosas são classificadas de acordo com a anatomia da região acometida e podem ser divididas em oclusão de ramo e da veia central da retina. O edema macular é a principal causa de baixa acuidade visual na Oclusão de Ramo da Veia Central da Retina (OVR). Sua detecção, localização e classificação são cruciais para a prevenção e tratamento da perda visual na OVR. A Biomicrospia Macular e a Angiofluoresceinografia são os métodos tradicionais de avaliação do edema macular na OVR, a Tomografia de Coerência Óptica (TCO) é uma tecnologia nova, que permite uma avaliação objetiva da morfologia macular. O objetivo primário do presente estudo foi avaliar, em uma mesma população, a acurácia dos métodos de diagnóstico do edema macular na OVR através da análise de três quesitos, aumento da espessura macular e da sua localização, presença de cistos intra-retinianos e a presença de descolamento seroso macular (DSM). Indivíduos com OVR foram selecionados com base nos achados fundoscópicos da doença e com tempo de história da doença entre três e vinte quatro meses. Todos os sujeitos foram submetidos a exames com o Stratus OCT (TCO), Angiofluoresceinografia digital (Angio) e o exame da biomicroscopia macular com lente de Volk de 78 D (BM) dentro do período de uma semana, além de exame oftalmológico completo. As medidas utilizadas para avaliação da acurácia diagnóstica foram o índice de concordância Kappa e a sensibilidade. Dos 32 indivíduos inicialmente avaliados, 8 foram posteriormente excluídos por não cumprirem os critérios de inclusão ou de exclusão, restando 24 indivíduos para análise. Na avaliação da espessura macular, a concordância entre BM e a TCO foi substancial e significante para a detecção do aumento da espessura macular com Kappa = 0,778 (p < 0,001) e a sensibilidade foi 95,5%. Na comparação entre a BM e a TCO para a detecção de cistos intra-retinianos, a concordância foi fraca com Kappa = 0,250 (p = 0,066) e a sensibilidade foi 57,9 %. A concordância entre a Angio e a TCO para os cistos foi pobre e não significante com Kappa = 0,124 (p = 0,237) e a sensibilidade foi 58,7 %. Houve uma correlação significante entre a presença de extravasamento na angiofluoresceinografia e a presença de cistos intra-retinianos na TCO (p=0,042). Na avaliação do DSM a concordância entre a BM e a TCO foi fraca com Kappa = 0,314 (p = 0,062) e a sensibilidade foi 60%, não houve concordância entre a Angio e a TCO para a detecção do DSM com Kappa = 0 e sensibilidade de 0%, e também não houve correlação significante entre a presença de descolamento seroso na TCO e a presença de extravasamento na angiofluoresceinografia (p=0,615). Os dados obtidos no presente estudo sugeriram que o Stratus OCT têm acurácia superior para a detecção dos cistos intra-retinianos e do descolamento seroso macular, se comparado à biomicroscopia macular e à angiofluoresceinografia / Retinal Vein Occlusions are complications of the retinal vascular system that can cause a great impact on vision. The Vein Occlusions are classified according to the anatomy of the affected region and can be categorized as: branch retinal vein occlusion and central retinal vein occlusion. Macular edema is the main cause for low visual acuity in Branch Retinal Vein Occlusion (BRVO). Its detection, location and classification are crucial for the prevention and treatment of vision loss in BRVO. Both Macular Biomicroscopy and Angiofluoresceinography are traditional methods for the evaluation of the macular edema in BRVO; the Optical Coherence Tomography (OCT) is a new technology that allows for an objective evaluation of macular morphology. The main objective of the present study was to evaluate, among the same population, the accuracy of the diagnostic methods of macular edema in BRVO through the analysis of three items: the increase of macular thickness and its location, the presence of intraretinal cysts, and the presence of serous macular detachment. Patients with BRVO were selected according to the fundoscopic findings of the disease and a disease history of three to twenty-four months. All of the individuals underwent exams with the Stratus OCT, digital Angiofluoresceinography (Angio) and a macular biomicroscopy with a 78D Volk lens (MB), within a period of one week, as well as a complete ophthalmologic exam. The parameters used in the evaluation of the diagnostic accuracy were sensitivity and the kappa coefficient. Of the 32 subjects who were initially evaluated, 8 were later excluded since they did not meet inclusion or exclusion criteria. The remaining 24 subjects were analyzed. In the evaluation of macular thickness, the concordance between the MB and the OCT was substantial and significant in the detection of the increase in macular thickness, with Kappa = 0.778 (p<0.001) and a sensitivity of 95.5%. When comparing the MB and the OCT in the detection of intraretinal cysts, the concordance was fair, with Kappa = 0.250 (p = 0.066) and a sensitivity of 57.9%. The concordance between the Angio and the OCT for cysts detection was poor and non significant, with Kappa = 0.124 (p = 0.237) and a sensitivity of 58.7%. There was a significant correlation between the presence of leakage in the angiofluoresceinography and the presence of intraretinal cysts in the OCT (p = 0.042). In the evaluation of the SMD, the concordance between the MB and the OCT was fair, with Kappa = 0.314 (p = 0.062) and a sensitivity of 60% an there was no concordance between the Angio and the OCT in the detection of SMD, with Kappa = 0 and sensitivity of 0%. There was also no significant correlation between the presence of serous detachment in the OCT and the presence of leakage in the angiofluoresceinography (p = 0.615). The results obtained in the present study suggest that Stratus OCT is more accurate to the detection of intraretinal cysts and serous macular detachment than macular biomicroscopy with a 78D Volk lens, and by angiofluoresceinography
|
22 |
Avaliação estrutural do disco óptico e da camada de fibras nervosas retinianas peripapilares em pacientes com retinopatia diabética submetidos a panfotocoagulação retiniana / Structural evaluation of the optic disc and peripapillary retinal nerve fiber layer in patients with diabetic retinopathy submitted to panretinal photocoagulationAzevedo, Breno Marques da Silva 04 April 2019 (has links)
Objetivos: Determinar o efeito da panfotocoagulação retiniana (PFC) nos parâmetros topográficos do disco óptico e na camada de fibras nervosas da retina (CFNR) peripapilar em pacientes com retinopatia diabética proliferativa (RDP). Métodos: Este é um estudo observacional prospectivo, de centro único. Trinta e oito olhos de 26 pacientes diabéticos foram submetidos a PFC para retinopatia diabética proliferativa. As estereofotografias (EFs) e os parâmetros do disco óptico foram avaliados usando o retinógrafo Visucam da Zeiss e a Tomografia de varredura a laser (TVL), respectivamente. A espessura da CFNR peripapilar foi medida por tomografia de coerência óptica (OCT) e polarimetria de varredura a laser (PVL). Todas as medições foram realizadas no início e 12 meses após a conclusão da PFC. Resultados: Trinta e oito olhos de 26 pacientes (15 mulheres) com média de idade de 53,7 anos (faixa etária de 26 a 74 anos) foram recrutados. Nenhuma diferença significativa foi encontrada entre a média horizontal e vertical para relação escavação/disco óptico (E/D) determinadas pelas EFs antes e após o tratamento com PFC (P = 0,461 e 0,839, respectivamente). Os valores globais dos parâmetros do disco óptico analisados com a TVL não mostraram nenhuma mudança significativa entre o baseline e 12 meses após o tratamento (área do disco, área da escavação, área da rima, volume da escavação, volume da rima, relação área da escavação/área do disco, relação linear do tamanho da escavação/disco, profundidade média da escavação, profundidade máxima da escavação, medida do formato da escavação, variação na altura do contorno, espessura média da CFNR e área transversal da CFNR). O OCT e o PVL não encontraram diferença significativa entre a CFNR peripapilar antes e após a PFC (P = 0,114 e P = 0,813, respectivamente). Conclusões: Nossos resultados sugerem que a PFC nos padrões realizados no presente estudo não causa significantes alterações morfológicas no disco óptico em pacientes diabéticos com RDP após um ano de acompanhamento / Purpose: To determine the effect of panretinal photocoagulation (PRP) on optic disc topographic parameters and peripapillary retinal nerve fiber layer (RNFL) in nonglaucomatous patients with proliferative diabetic retinopathy (PDR). Methods: This is a prospective, single center, observational study. Thirty-eight eyes of 26 diabetic patients underwent PRP for proliferative diabetic retinopathy. Stereoscopic disc photographs and optic nerve head (ONH) parameters were evaluated using the Zeiss fundus camera and the confocal scanning laser ophthalmoscopy (CSLO), respectively. The peripapillary RNFL thickness was measured by optical coherence tomography (OCT) and scanning laser polarimetry (SLP). All measurements were performed at baseline and 12 months after completion of PRP. Results: Thirty-eight eyes of 26 patients (15 female) with a mean age of 53.7 years (range 26 to 74 years) were recruited. No significant difference was found between mean horizontal and vertical cup to disc (C/D) ratio determined by stereoscopic disc photographs before and after PRP treatment (P=0.461 and 0.839, respectively). The global values of ONH parameters analyzed with the CSLO showed no significant change from baseline to 12 months (disc area, cup area, rim area, cup volume, rim volume, C/D area ratio, linear C/D ratio, mean cup depth, maximum cup depth, cup shape measure, height variation contour, mean retinal nerve fiber layer thickness and cross-sectional area). The OCT and SLP did not find significant difference between peripapillary RNFL before and after PRP (P=0.114 and P=0.813, respectively). Conclusion: Our results suggest that PRP as performed in this study does not cause significant morphological optic disk changes in diabetic PDR patients after one year of follow-up
|
Page generated in 0.0571 seconds