Spelling suggestions: "subject:"fotocoagulação"" "subject:"homocoagulação""
1 |
Estudo comparativo entre o laser endovenoso e a fleboextração convencional da veia safena interna em pacientes com varizes primariasMedeiros, Charles Angotti Furtado de 22 February 2005 (has links)
Orientador: George Carchedi Luccas / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciencias Medicas / Made available in DSpace on 2018-08-04T17:07:31Z (GMT). No. of bitstreams: 1
Medeiros_CharlesAngottiFurtadode_M.pdf: 7427028 bytes, checksum: 5fd6db5ff203ec8053444b0bde5a1966 (MD5)
Previous issue date: 2005 / Resumo: O diagnóstico de varizes é comum, sendo encontrado em até 25% das mulheres e 15% dos homens. Tais pacientes procuram tratamento médico por várias razões, inclusive preocupação estética. O desenvolvimento de instrumentais mais apropriados e flexíveis, bem como a busca por técnicas menos invasivas com resultados aceitáveis, a curto e longo prazos, possibilitou o aparecimento de novas modalidades terapêuticas. Com o objetivo de comparar a fotocoagulação endovenosa com a fleboextração total da veia safena interna, foi realizado um estudo prospectivo, analítico, do tipo ensaio clínico controlado e cego. Um total de 20 pacientes com insuficiência de veia safena interna bilateral foi operado de varizes no Hospital Estadual Sumaré durante o período de março de 2002 a fevereiro de 2004. Para cada caso, eram realizadas, aleatoriamente, as duas técnicas, sendo uma em cada membro inferior. Todas as variáveis pesquisadas foram submetidas à análise estatística. Como resultados mais expressivos, a técnica que utilizou o laser endovenoso apresentou menor dor, menor edema e menor hematoma durante o pós-operatório. Também no que se refere ao beneficio da cirurgia, a grande maioria dos pacientes respondeu que o membro operado com o laser foi o mais beneficiado dos dois. O exame de pletismografia a ar demonstrou melhora hemodinâmica nos dois grupos, sem, contudo obter a normalização dos valores do tempo de enchimento venoso em todos os casos. Conclui-se que a fotocoagulação endovenosa para o tratamento da veia safena interna em pacientes com varizes de membros inferiores é segura e bem tolerada, e apresenta resultados comparáveis aos da fleboextração convencional / Abstract: The diagnosis of varicose veins is common, being found in up to 25% of women and 15% of the men. Such patients seek medical treatment for some reasons, also aesthetic concern. The development of more appropriate and flexible instruments, as well as thesearch for less invasive techniques with acceptable results, the short and long term period, made possible the appearance of new therapeutically modalities. With the objective to compare the endovenous photocoagulation with the total stripping of the internal safenous vein, a study of the type was carried through controlled, randomized and blind clinical assay. A total of20 patients with insufficiency of bilateral internal safenous vein were operated of varices during the period of March of 2002 and February of 2004. For each in case that, two techniques, being one in each inferior member were carried through. The entire searched variable had been submitted to the analysis statistics. As major results, the technique that used the endovenous laser presented minor pain, minor edema and minor hematome during the postoperative course. Also as for the benefits of the surgery, the great majority of the patients answered that the member operated with the laser was the most benefited of the two. The air pletismography examination demonstrated hemodynamic improvement in the two groups, without however getting the normalization of the values of the venous filling time in all of them. The endovenous photocoagulation for the treatment of varicose veins is insurance and tolerated good. This technique presents resulted comparable to the ones of the conventional stripping of the internal safenous vein and can successfully be used with low index of complications / Mestrado / Cirurgia / Mestre em Cirurgia
|
2 |
Desenvolvimento de cavidade laser em 532nm para uso oftalmológico / Development of a 532nm laser cavity for ophthalmology applicationsRossi, Giuliano 25 September 2009 (has links)
O presente trabalho trata-se do desenvolvimento de uma cavidade Laser de estado sólido e geração de segundo harmônico, para fins oftalmológicos. A cavidade faz parte de um projeto maior que se refere a um fotocoagulador portátil, utilizado em diversos protocolos clínicos relacionados às doenças da retina e câmara anterior, como retinopatia diabética, retinopatia da prematuridade, glaucoma, edema macular e descolamento de retina. A cavidade proposta é composta por três espelhos dispostos em uma arquitetura em V. Um laser de diodo bombeia um cristal de Nd:YAG para a geração de laser em 1064nm que passa por um cristal de KTP para a geração de segundo harmônico em 532nm (laser verde). O sistema de acoplamento indexado à cavidade acopla até 90% da potência de saída em uma fibra óptica com núcleo de 100\'mü\'m. A cavidade projetada e implementada, produz um feixe com comprimento de onda de 532nm (laser verde), largura de banda de 0,5nm, potência máxima em torno de 2,5W na saída da fibra óptica e pulsos com duração máxima de 3s, que são requisitos para os tratamentos oftalmológicos associados a este tipo de equipamento. É importante destacar que a cavidade foi projetada e desenvolvida inteiramente com tecnologia nacional, sendo o primeiro trabalho desenvolvido no Brasil, que se tornou efetivamente um equipamento final para uso clínico. Além do projeto da cavidade laser, são descritos neste trabalho os sistemas mecânico e eletrônico, que possibilitaram seu funcionamento na integração do fotocoagulador. O fotocoagulador foi testado em pacientes voluntários da Escola Paulista de Medicina da UNIFESP, apresentando resultados comparáveis aos sistemas importados. / This work presents the research and the development of a solid state laser cavity with second harmonic generation for ophthalmological purpose. The laser cavity is part of a major project intended to produce a handle photocoagulator. This medical equipment is applied in several clinical protocols related to retinal and anterior chamber pathologies, such as diabetic retinopathy, retinopathy of prematurity, glaucoma, macular edema and retinal detachment. The present cavity is composed by three mirrors disposed in a V shape architecture. One laser diode pumps the Nd:YAG crystal to generate the 1064nm laser that is converted by second harmonic generation in 532nm through the KTP crystal (green laser). The coupling system attached in the cavity is able to collimate until 90% of the laser beam inside a optical fiber with 100 \'mü\'m core. The developed cavity produces a beam with wavelength of 532nm, spectral width of 0.5nm, maximum power around 2.5W in the end of the optical fiber and maximum pulse duration of 3s. Those parameters are requirements for ophthalmological treatments related to this kind of equipment. It is important to declare that the cavity was projected and developed in Brazil. This is the first work in this country that becomes effectively a device to clinical application. Besides the cavity design project, in this work also describes the mechanical and electronic sub systems that was responsible to the laser control and photocoagulator assembler. This product was tested in patients eyes from UNIFESP (Escola Paulista de Medicina), and showed similar results compared to the systems on the market.
|
3 |
Laser self-Raman dobrado intracavidade de alta potência CW operante na região amarela do espectro eletromagnético de aplicações oftalmológicas / High power intracavity doubled CW self-Raman laser operating in the yellow range of electromagnetic spectra of ophthalmological applicationsOrtega, Tiago Almeida 18 August 2011 (has links)
Este trabalho tem por objetivo o desenvolvimento e otimização de uma cavidade laser self-Raman de aplicações oftalmológicas. A cavidade laser é do tipo estado sólido bombeada longitudinalmente por um diodo laser infravermelho. A cavidade é dita self-Raman pois um cristal Raman intracavidade faz o papel de meio ativo e deslocador Raman. Esse tipo de configuração é extremamente vantajoso uma vez que promove uma redução dimensional, de custos e de perdas intracavidade. Outro elemento não linear intracavidade é responsável pela geração do segundo harmônico da primeira linha Stokes gerada pelo cristal Raman. Dessa maneira obtém-se radiação em 586.5 nm da cavidade laser, o que corresponde a porção amarela do espectro eletromagnético. Essa região amarelo-alaranjada do espectro é de muita importância e aplicabilidade na indústria, ciências e na medicina. Na oftalmologia, em particular, é de enorme interesse que se construa um laser amarelo para fotocoagulação da retina uma vez que há muito tempo sabe-se que essa porção do espectro possui uma absorção desprezível pela Xantofila, cromóforo abundantemente presente na mácula. A mácula é a porção da retina responsável pela visão central e não deve absorver radiação laser pois isso seria desastroso para o paciente. / The objective of this work is the development and optimization of a self-Raman laser cavity with ophthalmological applications. The laser cavity is a longitudinally diode pumped solid state laser. The laser cavity is so-called self-Raman because an intracavity Raman crystal plays a role as an active media and Raman shifter. This type of configuration is extremely advantageous because it promotes a reduction in costs, dimensions and intracavity losses. Another non linear intracavity element is responsible for the second harmonic generation of the first Stokes line generated by the Raman crystal. Thereby one obtains 586.5 nm radiation coming out of the laser cavity, a wavelength in the yellow portion of the electromagnetic spectra. This yellow-orange range of the spectra is of great importance because and has many and increasingly applications in science, industry and medicine. Particularly in ophthalmology, a yellow laser for retina photocoagulation is of great interest once it is well known that this portion of the spectra is negligibly absorbed by the Xanthophylls, pigment strongly present at the macula. The macula is the portion of the retina responsible for the central vision and because of this laser absorption would be disastrous for the patients eye.
|
4 |
Laser self-Raman dobrado intracavidade de alta potência CW operante na região amarela do espectro eletromagnético de aplicações oftalmológicas / High power intracavity doubled CW self-Raman laser operating in the yellow range of electromagnetic spectra of ophthalmological applicationsTiago Almeida Ortega 18 August 2011 (has links)
Este trabalho tem por objetivo o desenvolvimento e otimização de uma cavidade laser self-Raman de aplicações oftalmológicas. A cavidade laser é do tipo estado sólido bombeada longitudinalmente por um diodo laser infravermelho. A cavidade é dita self-Raman pois um cristal Raman intracavidade faz o papel de meio ativo e deslocador Raman. Esse tipo de configuração é extremamente vantajoso uma vez que promove uma redução dimensional, de custos e de perdas intracavidade. Outro elemento não linear intracavidade é responsável pela geração do segundo harmônico da primeira linha Stokes gerada pelo cristal Raman. Dessa maneira obtém-se radiação em 586.5 nm da cavidade laser, o que corresponde a porção amarela do espectro eletromagnético. Essa região amarelo-alaranjada do espectro é de muita importância e aplicabilidade na indústria, ciências e na medicina. Na oftalmologia, em particular, é de enorme interesse que se construa um laser amarelo para fotocoagulação da retina uma vez que há muito tempo sabe-se que essa porção do espectro possui uma absorção desprezível pela Xantofila, cromóforo abundantemente presente na mácula. A mácula é a porção da retina responsável pela visão central e não deve absorver radiação laser pois isso seria desastroso para o paciente. / The objective of this work is the development and optimization of a self-Raman laser cavity with ophthalmological applications. The laser cavity is a longitudinally diode pumped solid state laser. The laser cavity is so-called self-Raman because an intracavity Raman crystal plays a role as an active media and Raman shifter. This type of configuration is extremely advantageous because it promotes a reduction in costs, dimensions and intracavity losses. Another non linear intracavity element is responsible for the second harmonic generation of the first Stokes line generated by the Raman crystal. Thereby one obtains 586.5 nm radiation coming out of the laser cavity, a wavelength in the yellow portion of the electromagnetic spectra. This yellow-orange range of the spectra is of great importance because and has many and increasingly applications in science, industry and medicine. Particularly in ophthalmology, a yellow laser for retina photocoagulation is of great interest once it is well known that this portion of the spectra is negligibly absorbed by the Xanthophylls, pigment strongly present at the macula. The macula is the portion of the retina responsible for the central vision and because of this laser absorption would be disastrous for the patients eye.
|
5 |
Desenvolvimento de cavidade laser em 532nm para uso oftalmológico / Development of a 532nm laser cavity for ophthalmology applicationsGiuliano Rossi 25 September 2009 (has links)
O presente trabalho trata-se do desenvolvimento de uma cavidade Laser de estado sólido e geração de segundo harmônico, para fins oftalmológicos. A cavidade faz parte de um projeto maior que se refere a um fotocoagulador portátil, utilizado em diversos protocolos clínicos relacionados às doenças da retina e câmara anterior, como retinopatia diabética, retinopatia da prematuridade, glaucoma, edema macular e descolamento de retina. A cavidade proposta é composta por três espelhos dispostos em uma arquitetura em V. Um laser de diodo bombeia um cristal de Nd:YAG para a geração de laser em 1064nm que passa por um cristal de KTP para a geração de segundo harmônico em 532nm (laser verde). O sistema de acoplamento indexado à cavidade acopla até 90% da potência de saída em uma fibra óptica com núcleo de 100\'mü\'m. A cavidade projetada e implementada, produz um feixe com comprimento de onda de 532nm (laser verde), largura de banda de 0,5nm, potência máxima em torno de 2,5W na saída da fibra óptica e pulsos com duração máxima de 3s, que são requisitos para os tratamentos oftalmológicos associados a este tipo de equipamento. É importante destacar que a cavidade foi projetada e desenvolvida inteiramente com tecnologia nacional, sendo o primeiro trabalho desenvolvido no Brasil, que se tornou efetivamente um equipamento final para uso clínico. Além do projeto da cavidade laser, são descritos neste trabalho os sistemas mecânico e eletrônico, que possibilitaram seu funcionamento na integração do fotocoagulador. O fotocoagulador foi testado em pacientes voluntários da Escola Paulista de Medicina da UNIFESP, apresentando resultados comparáveis aos sistemas importados. / This work presents the research and the development of a solid state laser cavity with second harmonic generation for ophthalmological purpose. The laser cavity is part of a major project intended to produce a handle photocoagulator. This medical equipment is applied in several clinical protocols related to retinal and anterior chamber pathologies, such as diabetic retinopathy, retinopathy of prematurity, glaucoma, macular edema and retinal detachment. The present cavity is composed by three mirrors disposed in a V shape architecture. One laser diode pumps the Nd:YAG crystal to generate the 1064nm laser that is converted by second harmonic generation in 532nm through the KTP crystal (green laser). The coupling system attached in the cavity is able to collimate until 90% of the laser beam inside a optical fiber with 100 \'mü\'m core. The developed cavity produces a beam with wavelength of 532nm, spectral width of 0.5nm, maximum power around 2.5W in the end of the optical fiber and maximum pulse duration of 3s. Those parameters are requirements for ophthalmological treatments related to this kind of equipment. It is important to declare that the cavity was projected and developed in Brazil. This is the first work in this country that becomes effectively a device to clinical application. Besides the cavity design project, in this work also describes the mechanical and electronic sub systems that was responsible to the laser control and photocoagulator assembler. This product was tested in patients eyes from UNIFESP (Escola Paulista de Medicina), and showed similar results compared to the systems on the market.
|
6 |
Análise comparativa da acuidade visual em pacientes com oclusão de ramo de veia central da retina antes e após tratamento combinado de bevacizumabe intravítreo com fotocoagulação a laserGomes, Renato Vieira January 2012 (has links)
Submitted by Ana Lúcia Torres (bfmhuap@gmail.com) on 2017-09-29T23:29:42Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
DISSERTAÇAO RENATO GOMES.pdf: 1085453 bytes, checksum: 52c34bec90105d63a6d951a99405c02d (MD5) / Approved for entry into archive by Ana Lúcia Torres (bfmhuap@gmail.com) on 2017-09-29T23:31:18Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
DISSERTAÇAO RENATO GOMES.pdf: 1085453 bytes, checksum: 52c34bec90105d63a6d951a99405c02d (MD5) / Made available in DSpace on 2017-09-29T23:31:18Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
DISSERTAÇAO RENATO GOMES.pdf: 1085453 bytes, checksum: 52c34bec90105d63a6d951a99405c02d (MD5)
Previous issue date: 2012 / Santa Casa de Misericórdia de Vitória. Escola Superior de Ciências / Objetivo: Comparar a acuidade visual em pacientes com oclusão de ramo de veia central da retina (ORVCR), antes e após tratamento combinado de injeção intravítrea de bevacizumabe com fotocoagulação a laser.
Método: Uma análise retrospectiva de pacientes com ORVCR que foram tratados com injeção
intravítrea de bevacizumabe (1,25mg/0,05ml) seguida de fotocoagulação a laser na área
afetada. Os pacientes passaram por avaliação oftalmológica completa, incluindo medida da
acuidade visual (AV) com tabela de Snellen no momento do diagnóstico e nas visitas de
acompanhamento. Foram excluídos prontuários incompletos ou com erros de preenchimentos
e prontuários de pacientes com outras alterações oculares que pudessem interferir nas medidas da acuidade visual. Resultados: Foram analisados 26 prontuários (11 homens e 15 mulheres) de pacientes com diagnóstico de ORCVR no Serviço de Oftalmologia da Santa Casa de Vitória durante todo o ano de 2010. Todos os pacientes foram acompanhados por 6 meses. O tempo médio de baixa da acuidade visual antes do diagnóstico foi de 21,2 dias (1-140 dias). Com acuidade visual inicial média de 0.74 LogMAR (p<0.001) e com melhora média após 6 meses do início do tratamento para 0.32 LogMAR (p<0.001), representando assim um ganho médio de 0.42 LogMAR (p<0.001) ou 19.4 letras de ETDSR (p<0.001). Foram utilizados testes não paramétricos a fim de permitir mais generalização aos resultados evitando a premissa de normalidade. O teste de Wilcoxon foi utilizado para verificar a variação da acuidade visual inicial e final. Não foram observadas complicações oculares ou sistêmicas durante o acompanhamento. Conclusão: Houve melhora da acuidade visual comparando pré o pós tratamento combinado de injeção intravítrea de bevacizumabe com fotocoagulação a laser. A estabilidade do ganho obtido no tratamento combinado com a ausência de complicações demonstra o potencial do uso combinado de injeção intravítrea de bevacizumabe com fotocoagulação a laser no tratamento de ORVCR / Purpose: Compare the visual acuity (VA) in patients with branch retinal vein occlusion
(BRVO), before and after been treated with a combination of intravitreal injection of
bevacizumab followed by laser photocoagulation.
Method: A retrospective analyses of patients with BRVO that underwent a treatment of intravitreal injection of bevacizumab (1,25mg/ 0,05ml) followed by laser photocoagulation on the affected area. Patients went through complete eye examination, including visual acuity measure with Snellen chart on the diagnostic visit and on the follow-ups. Uncompleted and miswritten charts ware excluded as well as charts of patients with others ocular affections that could interfere in visual acuity measure Results: 26 charts (11 male and 15 female) of patients with BRVO from the Ophthalmological Department of Santa Casa de Misericórdia Hospital during 2010 were analyzed. All patients underwent a 6 months follow-up. The average VA loss before diagnostics was 21.2 days (1-140). The average VA was 0.74 LogMAR (p<0,001) with improvement after 6 month of treatment to 0.32 LogMAR (p<0,001),
representing a average gain of 0.42 LogMAR (p<0,001) or 19.4 ETDRS letters (p<0,001). Non parametric tests ware used to allow more generalization of the results avoiding normality assumption. The Wilcoxon was applied to verify de VA variation during de study. No eye or systemic complications ware observed during the study. Conclusions: Visual acuity gain occur comparing before and after treatment with
bevacizumab intravitreal injection followed by laser photocoagulation. The stability of the gain combined with a absences of complications demonstrate de potential of combined intravitreal bevacizumab and laser photocoagulation in patients with BRVO
|
7 |
Tratamento do edema macular difuso do diabético com triancinolona intravítrea e fotocoagulação com laser de argônio / Use of intravitreal triamcinolone and laser photocoagulation for the treatment of diffuse diabetic macular edemaSaraiva, Fábio Petersen 17 March 2008 (has links)
INTRODUÇÃO: O edema macular difuso é uma importante causa de baixa visual em portadores de diabetes mellitus. O tratamento clássico deste tipo de retinopatia consiste na fotocoagulação, entretanto, esta terapêutica é ineficaz em muitos casos. Neste trabalho, avaliou-se a eficácia do uso intravítreo da triancinolona acetonida associada à fotocoagulação com laser de argônio no tratamento do edema macular difuso diabético. Esta associação terapêutica foi comparada com o uso isolado de cada tratamento. MÉTODOS: Neste estudo, realizado entre junho de 2005 e setembro de 2006, foram estudados 30 pacientes diabéticos clinicamente controlados e portadores de edema macular difuso. Estes pacientes foram alocados de forma aleatória e proporcional em um dos seguintes grupos de tratamento: (1) fotocoagulação macular em grade com laser de argônio; (2) aplicação intravítrea de 4 mg de triancinolona acetonida; (3) associação dos itens anteriores. O seguimento foi realizado em intervalos pré-determinados de um dia, uma semana e mensalmente, até completar 6 meses. Foram analisados os parâmetros: acuidade visual corrigida LogMAR; espessura macular central e volume macular total medido pela tomografia de coerência óptica; e pressão intra-ocular aferida pelo tonômetro de Goldmann. RESULTADOS: A fotocoagulação com laser não reduziu de forma estatisticamente significativa a espessura macular central (p=0,0862) e o volume macular total (p=0,11). Esta redução foi significativa e estatisticamente semelhante nos outros dois grupos (p<0,001). Todos os grupos apresentaram melhora da acuidade visual (p=0,003), entretanto, o grupo que recebeu a associação do laser com a triancinolona intravítrea, obteve maior percentagem de pacientes com ganho de 10 ou mais letras de visão no quarto e quinto mês de seguimento (p=0,026; p=0,034). A pressão intra-ocular elevou-se em 5 mmHg ou mais em 12 pacientes, sendo seis no grupo submetido apenas a triancinolona e os outros seis no grupo que recebeu a associação de tratamento (p<0,001).Todos estes casos foram bem controlados com colírio de maleato de timolol 0,5%. CONCLUSÕES: O uso simultâneo da fotocoagulação com a triancinolona intravítrea proporcionou maior ganho de linhas de visão do que o uso isolado de cada tratamento. A fotocoagulação com laser foi a única terapia que não reduziu de forma significativa a espessura e o volume macular total e, também, foi a única que não apresentou casos de hipertensão ocular durante o seguimento. / INTRODUCTION: The diffuse macular edema is an important cause of visual impairment in diabetic subjects. Laser photocoagulation is the main treatment for this disorder, however, it is not effective in a large number of patients. In this study, we evaluated the efficacy of intravitreal use of triamcinolone acetonide combined with laser photocoagulation for the treatment of diffuse diabetic macular edema and we compare it with either laser alone or intra-vitreal triancinolone. METHODS: In this study, performed between june 2005 and september 2006, we studied 30 well controlled diabetic patients with diffuse macular edema. These patients were randomly divided into the following treatment groups: (1) macular grid photocoagulation; (2) intravitreal injection of 4 mg of triamcinolone acetonide; (3) combination of the two previous therapies. Follow up was scheduled at predetermined intervals of one day, one week and monthly until completion of six months. The following parameters were analyzed: LogMAR best corrected visual acuity; central macular thickness and total macular volume measured by ocular coherence tomography; and intraocular pressure assessed by Goldman\'s tonometer. RESULTS: Grid photocoagulation did not significantly reduce the central macular thickness (p=0,0862) or the total macular volume (p=0,11). On the other side, this reduction was significant and statistically similar in the others two groups (p<0,001). All groups improved the mean visual acuity (p=0,003), however, the group that received the association treatment had a higher percentage of patients gaining 10 or more letters at the fourth and fifth month of follow up (p=0,026; p=0,034). A rise in 5 or more mmHg in intraocular pressure was observed in 12 patients; half of them was in the triamcinolone group and the other half was in the group that received combined therapies (p<0,001). These cases with elevated intraocular pressure were well controlled with timolol maleate 0,5% drops. CONCLUSION: The simultaneous use of photocoagulation and intravitreal triamcinolone provided a higher gain of visual lines than the isolated use of each treatment. The laser photocoagulation was the only therapy that did not significantly reduce the macular volume and the macular thickness, however, it was also the only one that did not present cases of ocular hypertension during follow up.
|
8 |
Fotocoagulação de acordo com o protocolo ETDRS modificado versus laser diodo sublimiar em micropulsos para tratamento de edema macular diabético: Ensaio clínico-comparativo / Randomized Clinical Trial Evaluating mETDRS versus Normal or High-Density Micropulse Photocoagulation for Diabetic Macular EdemaLavinsky, Daniel [UNIFESP] 29 June 2011 (has links) (PDF)
Made available in DSpace on 2015-07-22T20:50:15Z (GMT). No. of bitstreams: 0
Previous issue date: 2011-06-29 / Objetivo: Comparar a fotocoagulação focal e em grade de acordo com o protocolo do Early Treatment Diabetic Retinopathy Study modificado (mETDRS) utilizando fotocoagulação com laser diodo 810nm sublimiar em micropulsos e densidade normal (FSM-DN) ou aumentada (FSM-DA) no tratamento do edema macular diabético (EMD). Métodos: Foi conduzido um estudo randomizado, controlado, prospectivo, duplo mascarado com pacientes não tratados com EMD e melhor acuidade visual corrigida (MAVC), pior que 20/40 e melhor que 20/400. Pacientes foram aleatorizados para receber fotocoagulação de acordo com o protocolo mETDRS (42 pacientes), FSM-DN (39 pacientes) ou FSM-DA (42 pacientes). Imediatamente antes do tratamento, 3, 6, bem como 12 meses após ele, todos os pacientes foram submetidos a exame oftalmológico, MAVC, retinografia colorida, angiografia fluorescente e tomografia de coerência óptica (OCT). Efeitos adversos nas diferentes técnicas de fotocoagulação foram observados durante o acompanhamento do estudo. Resultados: Durante o acompanhamento, todos os grupos apresentaram redução da espessura macular central, com diminuição no grupo FSM-DA de 93μm em três meses, 117μm em seis meses e 144μm em nove meses, comparado à redução de 67, 94 e 112μm em três, seis e nove meses respectivamente, no grupo mETDRS. Já o grupo FSM-DN apresentou redução de 20μm em três e seis meses e 34μm em nove meses, significativamente inferior aos grupos FSM-DA e mETDRS. Em relação à acuidade visual, houve melhora da MAVC gradual em três, seis e nove meses nos grupos FSM-DA e mETDRS sem diferenças estatisticamente significativas entre estes grupos, porém ambos superiores ao grupo FSM-DN, que não apresentou mudança na acuidade visual nesses períodos. Em doze meses, o grupo FSM-DA teve o melhor resultado em termos de MAVC (0,25 logMAR), seguido do grupo mETDRS (0,08 logMAR), enquanto o grupo FSM-DN não apresentou melhora significativa na MAVC (0,03 logMAR) (p<0,001). Todos os grupos apresentaram redução estatisticamente significativa da espessura macular central no OCT (p<0,001). O grupo FSM-DA demonstrou a maior redução (154μm), porém não foi estatisticamente significativa em relação ao grupo mETDRS (126μm; p=0,75). Não foram observados efeitos adversos graves nas diferentes formas de tratamento. Conclusão: Em um ano, a resposta clínica do grupo FSM-DA foi superior aos grupos mETDRS e FSM-DN, baseada na medida de espessura central da mácula e acuidade visual. Estes dados sugerem que a técnica de FSM-DA pode ser utilizada como conduta preferível para o tratamento de EMD, porém estudos clínicos multicêntricos são necessários para confirmar estes resultados. / Purpose: To compare modified Early Treatment Diabetic Retinopathy Study (ETDRS) focal/grid laser photocoagulation with normal-density (ND-SDM) or high-density (HD-SDM) subthreshold diode-laser micropulse photocoagulation for the treatment diabetic macular edema (DME). Methods: We conducted a prospective, randomized, controlled, double-masked clinical trial with patients with previously untreated DME and best corrected visual acuity (BCVA) worse than 20/40 and better than 20/400. Patients were randomized to receive either modified ETDRS focal / grid photocoagulation (42 patients), ND-SDM (39 patients) or HD-SDM (42 patients). Before treatment and 3, 6 and 12 months after treatment, all patients underwent ophthalmic examinations, BCVA, color fundus photography, fluorescein angiography and optical coherence tomography (OCT). Results: At 12 months, the HD-SDM group had the best improvement in BCVA (0.25 logMAR), followed by the modified ETDRS group (0.08 logMAR), while no improvements were seen in the ND-SDM group (0.03 logMAR). All groups showed statistically significant progressive reduction of CMT throughout the study (p<0.001). The HD-SDM group exhibited the greatest CMT reduction (154 μm), which was not significantly different from that of the modified ETDRS group (126 μm; p=0.75). Conclusions: At 1 year, the clinical performance of HD-SDM was superior to that of the modified ETDRS photocoagulation technique based on the anatomic and functional measures of improvement used in this investigation. A rationale for this treatment modality as a preferable approach is suggested, and the precise role of sub-threshold micropulse laser treatment may become more defined as experience grows, guided by optimized treatment guidelines and more comprehensive trials. / TEDE / BV UNIFESP: Teses e dissertações
|
9 |
Tratamento do edema macular difuso do diabético com triancinolona intravítrea e fotocoagulação com laser de argônio / Use of intravitreal triamcinolone and laser photocoagulation for the treatment of diffuse diabetic macular edemaFábio Petersen Saraiva 17 March 2008 (has links)
INTRODUÇÃO: O edema macular difuso é uma importante causa de baixa visual em portadores de diabetes mellitus. O tratamento clássico deste tipo de retinopatia consiste na fotocoagulação, entretanto, esta terapêutica é ineficaz em muitos casos. Neste trabalho, avaliou-se a eficácia do uso intravítreo da triancinolona acetonida associada à fotocoagulação com laser de argônio no tratamento do edema macular difuso diabético. Esta associação terapêutica foi comparada com o uso isolado de cada tratamento. MÉTODOS: Neste estudo, realizado entre junho de 2005 e setembro de 2006, foram estudados 30 pacientes diabéticos clinicamente controlados e portadores de edema macular difuso. Estes pacientes foram alocados de forma aleatória e proporcional em um dos seguintes grupos de tratamento: (1) fotocoagulação macular em grade com laser de argônio; (2) aplicação intravítrea de 4 mg de triancinolona acetonida; (3) associação dos itens anteriores. O seguimento foi realizado em intervalos pré-determinados de um dia, uma semana e mensalmente, até completar 6 meses. Foram analisados os parâmetros: acuidade visual corrigida LogMAR; espessura macular central e volume macular total medido pela tomografia de coerência óptica; e pressão intra-ocular aferida pelo tonômetro de Goldmann. RESULTADOS: A fotocoagulação com laser não reduziu de forma estatisticamente significativa a espessura macular central (p=0,0862) e o volume macular total (p=0,11). Esta redução foi significativa e estatisticamente semelhante nos outros dois grupos (p<0,001). Todos os grupos apresentaram melhora da acuidade visual (p=0,003), entretanto, o grupo que recebeu a associação do laser com a triancinolona intravítrea, obteve maior percentagem de pacientes com ganho de 10 ou mais letras de visão no quarto e quinto mês de seguimento (p=0,026; p=0,034). A pressão intra-ocular elevou-se em 5 mmHg ou mais em 12 pacientes, sendo seis no grupo submetido apenas a triancinolona e os outros seis no grupo que recebeu a associação de tratamento (p<0,001).Todos estes casos foram bem controlados com colírio de maleato de timolol 0,5%. CONCLUSÕES: O uso simultâneo da fotocoagulação com a triancinolona intravítrea proporcionou maior ganho de linhas de visão do que o uso isolado de cada tratamento. A fotocoagulação com laser foi a única terapia que não reduziu de forma significativa a espessura e o volume macular total e, também, foi a única que não apresentou casos de hipertensão ocular durante o seguimento. / INTRODUCTION: The diffuse macular edema is an important cause of visual impairment in diabetic subjects. Laser photocoagulation is the main treatment for this disorder, however, it is not effective in a large number of patients. In this study, we evaluated the efficacy of intravitreal use of triamcinolone acetonide combined with laser photocoagulation for the treatment of diffuse diabetic macular edema and we compare it with either laser alone or intra-vitreal triancinolone. METHODS: In this study, performed between june 2005 and september 2006, we studied 30 well controlled diabetic patients with diffuse macular edema. These patients were randomly divided into the following treatment groups: (1) macular grid photocoagulation; (2) intravitreal injection of 4 mg of triamcinolone acetonide; (3) combination of the two previous therapies. Follow up was scheduled at predetermined intervals of one day, one week and monthly until completion of six months. The following parameters were analyzed: LogMAR best corrected visual acuity; central macular thickness and total macular volume measured by ocular coherence tomography; and intraocular pressure assessed by Goldman\'s tonometer. RESULTS: Grid photocoagulation did not significantly reduce the central macular thickness (p=0,0862) or the total macular volume (p=0,11). On the other side, this reduction was significant and statistically similar in the others two groups (p<0,001). All groups improved the mean visual acuity (p=0,003), however, the group that received the association treatment had a higher percentage of patients gaining 10 or more letters at the fourth and fifth month of follow up (p=0,026; p=0,034). A rise in 5 or more mmHg in intraocular pressure was observed in 12 patients; half of them was in the triamcinolone group and the other half was in the group that received combined therapies (p<0,001). These cases with elevated intraocular pressure were well controlled with timolol maleate 0,5% drops. CONCLUSION: The simultaneous use of photocoagulation and intravitreal triamcinolone provided a higher gain of visual lines than the isolated use of each treatment. The laser photocoagulation was the only therapy that did not significantly reduce the macular volume and the macular thickness, however, it was also the only one that did not present cases of ocular hypertension during follow up.
|
10 |
Avaliação estrutural do disco óptico e da camada de fibras nervosas retinianas peripapilares em pacientes com retinopatia diabética submetidos a panfotocoagulação retiniana / Structural evaluation of the optic disc and peripapillary retinal nerve fiber layer in patients with diabetic retinopathy submitted to panretinal photocoagulationAzevedo, Breno Marques da Silva 04 April 2019 (has links)
Objetivos: Determinar o efeito da panfotocoagulação retiniana (PFC) nos parâmetros topográficos do disco óptico e na camada de fibras nervosas da retina (CFNR) peripapilar em pacientes com retinopatia diabética proliferativa (RDP). Métodos: Este é um estudo observacional prospectivo, de centro único. Trinta e oito olhos de 26 pacientes diabéticos foram submetidos a PFC para retinopatia diabética proliferativa. As estereofotografias (EFs) e os parâmetros do disco óptico foram avaliados usando o retinógrafo Visucam da Zeiss e a Tomografia de varredura a laser (TVL), respectivamente. A espessura da CFNR peripapilar foi medida por tomografia de coerência óptica (OCT) e polarimetria de varredura a laser (PVL). Todas as medições foram realizadas no início e 12 meses após a conclusão da PFC. Resultados: Trinta e oito olhos de 26 pacientes (15 mulheres) com média de idade de 53,7 anos (faixa etária de 26 a 74 anos) foram recrutados. Nenhuma diferença significativa foi encontrada entre a média horizontal e vertical para relação escavação/disco óptico (E/D) determinadas pelas EFs antes e após o tratamento com PFC (P = 0,461 e 0,839, respectivamente). Os valores globais dos parâmetros do disco óptico analisados com a TVL não mostraram nenhuma mudança significativa entre o baseline e 12 meses após o tratamento (área do disco, área da escavação, área da rima, volume da escavação, volume da rima, relação área da escavação/área do disco, relação linear do tamanho da escavação/disco, profundidade média da escavação, profundidade máxima da escavação, medida do formato da escavação, variação na altura do contorno, espessura média da CFNR e área transversal da CFNR). O OCT e o PVL não encontraram diferença significativa entre a CFNR peripapilar antes e após a PFC (P = 0,114 e P = 0,813, respectivamente). Conclusões: Nossos resultados sugerem que a PFC nos padrões realizados no presente estudo não causa significantes alterações morfológicas no disco óptico em pacientes diabéticos com RDP após um ano de acompanhamento / Purpose: To determine the effect of panretinal photocoagulation (PRP) on optic disc topographic parameters and peripapillary retinal nerve fiber layer (RNFL) in nonglaucomatous patients with proliferative diabetic retinopathy (PDR). Methods: This is a prospective, single center, observational study. Thirty-eight eyes of 26 diabetic patients underwent PRP for proliferative diabetic retinopathy. Stereoscopic disc photographs and optic nerve head (ONH) parameters were evaluated using the Zeiss fundus camera and the confocal scanning laser ophthalmoscopy (CSLO), respectively. The peripapillary RNFL thickness was measured by optical coherence tomography (OCT) and scanning laser polarimetry (SLP). All measurements were performed at baseline and 12 months after completion of PRP. Results: Thirty-eight eyes of 26 patients (15 female) with a mean age of 53.7 years (range 26 to 74 years) were recruited. No significant difference was found between mean horizontal and vertical cup to disc (C/D) ratio determined by stereoscopic disc photographs before and after PRP treatment (P=0.461 and 0.839, respectively). The global values of ONH parameters analyzed with the CSLO showed no significant change from baseline to 12 months (disc area, cup area, rim area, cup volume, rim volume, C/D area ratio, linear C/D ratio, mean cup depth, maximum cup depth, cup shape measure, height variation contour, mean retinal nerve fiber layer thickness and cross-sectional area). The OCT and SLP did not find significant difference between peripapillary RNFL before and after PRP (P=0.114 and P=0.813, respectively). Conclusion: Our results suggest that PRP as performed in this study does not cause significant morphological optic disk changes in diabetic PDR patients after one year of follow-up
|
Page generated in 0.0403 seconds