• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 1
  • Tagged with
  • 19
  • 19
  • 19
  • 19
  • 17
  • 15
  • 15
  • 15
  • 15
  • 15
  • 12
  • 7
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Correlação da tensão no intermediário e as medidas de comprimento, altura e angulação de infraestruturas de próteses sobre implantes / Correlation of abutment tension and measures of length, height and angle of implant-supported prostheses framework

Piras, Fernanda Furtado 28 May 2015 (has links)
A adaptação passiva e estabilidade têm sido descritos como pré-requisitos importantes na escolha dos materiais e técnicas de confecção em prótese implantossuportada. A proposta deste trabalho foi estudar, com auxílio dos strain gauges, a deformação média gerada nos intermediários após a aplicação de carga axial em infraestruturas confeccionadas por três diferentes materiais. Além disso, através da microscopia confocal a laser, avaliar as medidas de comprimento, altura e angulação desses espécimes e mini pilares. Esses dados foram submetidos à análise estatística, a fim de encontrar possível correlação entre a deformação gerada e as medidas internas das infraestruturas com as externas dos intermediários em que foram parafusadas. Para essa investigação foi utilizado um modelo em poliuretano com dois implantes, hexágono externo, posicionados nas áreas dos dentes 43 e 45. A partir deste modelo, 12 infraestruturas de três elementos foram fabricadas e divididas em 3 grupos (n=4) de acordo com a técnica utilizada: (C) fundição convencional em Ni-Cr; (U) usinada em zircônia por CAD/CAM e (S) sinterizada a laser em Co-Cr pelo CAD/CAM. Durante a aplicação de carga axial, as tensões geradas foram registradas por extensômetros unidos aos intermediários, e avaliadas quantitativamente e qualitativamente. De maneira geral, houve um predomínio de áreas de compressão, sendo que as poucas áreas de tração apresentaram baixos valores. O grupo sinterizado a laser foi o único que apresentou forças compressivas para todos os sensores. Os grupos usinado e convencional apresentaram comportamento semelhante, diferindo apenas em uma região. Posteriormente, as infraestruturas e os intermediários foram submetidos à microscopia confocal para avaliação de ângulo, comprimento e altura de suas paredes internas (infraestruturas) e externas (intermediários), nas regiões correspondentes à localização dos strain gauges. Para a angulação, todos os grupos mostraram valores semelhantes entre si e maiores que os dos mini pilares. Quanto ao comprimento e altura, todos valores foram diferentes entre si. Em relação aos mini pilares, os valores foram maiores na altura e menores no comprimento. Estes resultados foram analisados pelo método estatístico de Pearson o que levou à conclusão que, para algumas regiões dos medidores de tensão, há correlação entre deformação e comprimento, e também, deformação e ângulo. Quanto maior o ângulo, e quanto menor for o comprimento, maior a deformação mostrada. / The passive adaptation and stability have been described as important prerequisites in the choice of materials and manufacturing techniques in implant-supported prosthesis. The aim of this work was to study, with the aid of strain gauges, the average deformation generated in the abutment, after application of axial load on frameworks made up of three different materials. Besides, through confocal laser microscopy, assess the length, height, and angle of these specimens, and abutment. These data were statistically analyzed in order to find possible correlation between the deformation generated, and the internal measures of the framework and the external measure of the abutments they were screwed on. For this research, a model made of polyurethane with two external hexagon implants, positioned in the areas of teeth 43 and 45 was used. From this model, 12 three-element frameworks were fabricated and divided into 3 groups (n = 4), according to the technique used: (C) conventional Ni-Cr casting; (U) machined zirconia CAD / CAM and (S) laser sintered Co-Cr by CAD / CAM. During application of axial load, the tensions generated were recorded by strain gauges attached to the abutments, and evaluated quantitatively and qualitatively. In general, there was a predominance of compression areas, and the few areas of traction showed low values. The laser sintered group was the only one with compressive forces for all sensors. The milled and conventional groups behaved similarly, differing only in a region. Subsequently, the framework and the abutment were analyzed by confocal microscopy for evaluation of angle, length and height of the inner (framework) and outer (abutment) walls in regions corresponding to the location of strain gauges. For the variable angle, all groups showed similar values among themselves and greater than the abutments. As for the variables length and height, all values were different. Regarding the abutments, the values were higher in height and smaller in length. These results were analyzed by Pearson statistical method, leading to the conclusion that, for some regions, there was correlation between deformation and length, and also deformation and angle. The higher the angle and the smaller the length, the greater the deformation shown.
2

Avaliação clínica e radiográfica de implantes utilizados como pilares de próteses inferiores implantossuportadas do tipo protocolo, colocadas sob carga imediata, empregando dois sistemas reabilitadores após 7 anos / Clinical and radiographic evaluation of implants used to support mandibular complete full-arch fixed prosthesis employing two rehabilitation systems with immediate loading after 7 years

Ayub, Karen Vaz 04 October 2013 (has links)
Esta pesquisa avaliou o sucesso de implantes utilizados como pilares de próteses inferiores implantossuportada do tipo protocolo, empregando dois sistemas reabilitadores, sob carga imediata, após 7 anos. Foram pesquisados os seguintes aspectos: índices de placa e de sangramento, estabilidade dos implantes por frequência de ressonância (FR) e perda óssea marginal. Foram avaliados 76 implantes, em 19 pacientes, divididos em 2 grupos: A (n=12, All-on-four® - Nobel Biocare®) e B (n=7, Neopronto® - Neodent®). Os pacientes foram acompanhados nos momento da instalação dos implantes (inicial), 6 meses, 1, 2 e 7 anos após a instalação. Os resultados mostraram uma taxa de sucesso de 100% para os implantes do grupo A e de 90% para o grupo B. Os índices de placa não apresentaram diferenças estatisticamente significativas e foram, no grupo A, de 71,87%, 63,54% e 47,92%, e, no grupo B de 26,78%, 41,07% e 37,50%, para as avaliações de 1, 2 e 7 anos, respectivamente. O índice de sangramento para o grupo A foi de 43,75%, 42,71% e 43,75% e para o grupo B foi de 53,57%, 51,79% e 48,21%, nos tempos de avaliação de 1, 2 e 7 anos, respectivamente, sem diferenças estatísticas. Não foi observado supuração em nenhum tempo de avaliação. Os resultados de FR não diferiram estatísticamente entre os dois grupos, entretanto, diminuíram entre a avaliação inical (grupo A = 69,27ISQ e grupo B = 68,29ISQ) e de 6 meses (grupo A = 64,65ISQ e grupo B = 66,50ISQ), e aumentaram nos anos seguintes para os 2 grupos, sendo para o grupo A de 66,17ISQ, 66,05ISQ e 69,87ISQ e para o grupo B de 67,78ISQ, 68,13ISQ e 73,61ISQ para os tempos de 1, 2 e 7 anos, respectivamente. Em relação a perda óssea, existiu diferença significativa entre grupos e foi de 0,49mm e 0,67mm após 1 ano e de 1,03mm e 1,27mm, após 7 anos, para os grupos A e B, respectivamente. Em relação à posição dos implantes, o grupo B apresentou diferença estatística entre os implantes centrais e distais nas avaliações de FR e perda óssea. Concluiu-se que 1- a taxa de sucesso foi de 100% para o grupo A e de 90% para o grupo B; 2- os índices de placa e de sangramento diminuíram ao longo dos anos de avaliação; 3- a FR foi semelhante entre os grupos, mas com diferença significativa no grupo A para o critério tempo e, no grupo B para os critérios tempos de avaliação e posição dos implantes; 4- perda da altura da crista óssea foi diferente significativamente entre os grupos, sendo maior no grupo B. / This study evaluated the success of implants used to support mandibular complete full-arch fixed prosthesis employing two rehabilitation systems with immediate loading after 7 years. The following aspects were investigated: plaque and bleeding index, implant stability by resonance frequency analysis and marginal bone loss. The 76 implants were evaluated in 19 patients divided in 2 groups: A (n=12, All-on-four® - Nobel Biocare®) and B (n=7, Neopronto® - Neodent®). The follow-up visits were at the time of implant placement (initial), 6 months, 1, 2 and 7 years after surgery. The results showed a success rate of 100% for implants in group A and 90% for group B. The plaque index did not differ statistically signifcant and were in group A, 71.87%, 63.54% and 47.92%, and in group B 26.78%, 41.07% and 37, 50% for 1, 2 and 7 years of follow-up, respectively. The bleeding index for group A was 43.75%, 42.71% and 43.75% and for group B was 53.57%, 51.79% and 48.21%, for 1, 2 and 7 years of follow-up, respectively, no statistical differences. Suppuration was not observed at any time of evaluation. The results of FR did not differ significantly between groups, however, decreased between initial (group A = 69,27ISQ and group B = 68,29 ISQ) and 6 months (group A = 64,65ISQ and group B = 66,50ISQ), and increased in the following evaluations for both groups, in group A was 66,17ISQ, 66,05ISQ and 69,87ISQ and group B was 67,78ISQ, 68,13ISQ and 73,61ISQ for 1, 2 and 7 years of follow-up, respectively. In relation to bone loss, a significant difference existed between groups and was 0,49mm and 0,67 mm after 1 year and 1,03mm and 1,27mm after 7 years, for groups A and B, respectively. Regarding the position of the implants, group B showed statistical difference between the central and distal implants for FR and bone loss. It was concluded that 1- Success rate was 100% for group A and 90% for group B; 2 - Plaque and bleeding index decreased over the follow-up; 3- FR was similar between groups, but with a significant difference in group A for thw criterion time, and in group B for the criteria evaluation times and position of the implants, 4- bone loss was significantly different between groups, and higher in group B.
3

Proteses fixas implanto-retidas : influencia do pilar intermediario e dos ciclos de cocção da ceramica nos desajustes e nas tensões induzidas as fixações / Implant supported prosthesis : influence of abutment and porcelain firing cycles on misfit and stress around implants

Tramontino-Mesquita, Vanessa Silva, 1982- 27 February 2008 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-10T13:58:31Z (GMT). No. of bitstreams: 1 Tramontino-Mesquita_VanessaSilva_M.pdf: 2155429 bytes, checksum: 5050e6eb80efb708a774530922aee871 (MD5) Previous issue date: 2008 / Resumo: Especula-se que ciclos de cocção da cerâmica geram aumento nos desajustes marginais. Em próteses sobre implantes se imagina que possam motivar aumento das tensões induzidas às fixações, tensões estas, que podem variar em função do tipo de pilar protético intermediário entre a prótese e os implantes. Assim, o propósito deste estudo foi avaliar a influência do ciclo de cocção da cerâmica e uso de pilar intermediário no desajuste marginal e nas tensões induzidas aos implantes, produzidas por próteses parciais fixas de 3 elementos parafusadas sobre 2 implantes. Foram confeccionadas 20 infraestruturas metálicas simulando próteses parciais fixas de 3 elementos retidas por 2 implantes osseointegrados e fundidas em titânio comercialmente puro (Ti c.p.), obtidas partir de um modelo mestre. As estruturas foram dividas em 2 grupos, sendo o grupo pilar cônico composto por 10 estruturas retidas por parafusos a pilares intermediários cônicos padrão Branemark com cintas cervicais de 1 mm para peças múltiplas e o grupo UCLA composto por 10 estruturas retidas por parafusos diretamente sobre as fixações utilizando cilindros protéticos tipo UCLA com cintas cervicais de 1 mm sem contra-hexágono de travamento para peças múltiplas. As infra-estruturas de ambos os grupos sofreram simulação dos diversos ciclos de cocção da cerâmica, objetivando a avaliação dos desajustes marginais e das tensões induzidas às fixações. As tensões foram avaliadas por extensiometria e os desajustes por microscopia óptica, sendo aferidos após cada ciclo de cocção, sendo os resultados confrontados com a situação imediatamente pós-fundição (controle). Os valores das tensões foram correlacionados com os valores de desajuste marginal medidos nas interfaces entre pilares e/ou fixações e cilindros protéticos, com aumento de 120 x, obedecendo ao protocolo de aperto do parafuso único, sendo realizados na situação pós-fundição (controle) e após cada ciclo de cocção da cerâmica. Foi realizada a análise de variância em esquema de parcela subdividida, sendo a parcela os grupos de tratamento e os ciclos de cocção da cerâmica, a subparcela. O teste de Tukey foi utilizado para comparação múltipla, com nível de significância de 5%. Não houve diferença significativa (p=0,601) na indução de tensões aos implantes devido ao uso de pilar intermediário (pilar cônico: 580,06 ± 253,93gf; UCLA: 665,35 ± 173,99gf). Porém, notou-se decréscimo nos valores de tensão devido às etapas do ciclo de cocção da cerâmica. A análise do desajuste marginal revelou haver interação entre o grupo de tratamento e o ciclo de cocção da cerâmica (p=0,002), sendo que as menores médias de desajuste ocorreram antes da exposição das infraestruturas aos ciclos de cocção (pilar cônico: 118,07 ± 58,61µm; UCLA: 83,93 ± 25,63 µm). Concluiu-se que a presença de um pilar intermediário cônico em infraestruturas de 3 elementos fundidas em Ti c.p. não reduziu as tensões induzidas às fixações e que os ciclos de cocção da cerâmica causaram aumento no desajuste marginal e redução nas tensões induzidas às fixações. / Abstract: It is speculated that porcelain firing cycles cause an increase on marginal misfit. This effect is imagined to origin an increase on strains around implants, when screwing the metallic frameworks, and it is supposed to be decreased by the use of an abutment between the framework and the implant. Thus, the aim of this study was to evaluate the influence of the porcelain firing cycle and of the use of conic abutments on marginal misfit and on strains around implants originated by screwing 3-element fixed partial dentures over 2 implants. Twenty metallic frameworks were fabricated, casting commercially pure titanium, obtained from a master cast, simulating 3-element fixed partial dentures, retained by 2 implants. The structures were divided into two groups, where conic abutment group was composed by 10 structures screwed to Branemark-type conic multi-unit abutments with 1 mm cervical belts and UCLA group composed by 10 structures screwed directly to the implants using non-engaging multi-unit UCLA cylinders with 1 mm cervical belts. All the frameworks were submitted to porcelain firing cycle simulation, aiming the evaluation of marginal misfit and strains around implants. Strains were analyzed by the use of strain gauges and misfit was analyzed by an optical microscope, both after each firing cycle and the results were confronted to the as-cast situation (control). The strains values were correlated with misfit values, which was measured in the interface of the abutment or implant and the prosthetic cylinder, following the one-screw test, being achieved on the as cast situation and after each firing cycle. Multivariate analysis was applied in a sub divided parcel scheme and the treatments were considered as the parcel and the firing cycles as the sub parcel. Tukey¿s test was employed to multiple comparisons, with significance level at 5%. There was no significant difference (p=0.601) on strains around implants due to the use of the abutment (conic abutment: 580.06 ± 253.93gf; UCLA: 665.35 ± 173.99gf). However, a decrease on strains values was observed, due to the porcelain firing cycle. Misfit analysis presented an interaction between the treatment groups and the firing cycles (p=0.002). The lower misfit mean values occurred before the frameworks were exposed to the firing cycles (conic abutment: 118.07 ± 58.61µm; UCLA: 83.93 ± 25.63 µm). It is concluded that the presence of a conic abutment on a 3 elements partial fixed prosthesis cast in commercially pure titanium did not decrease strains around implants and that the porcelain firing cycles caused an increase on marginal misfit and a decrease on strains around implants. / Mestrado / Protese Dental / Mestre em Clínica Odontológica
4

Avaliação clínica e radiográfica de implantes utilizados como pilares de próteses inferiores implantossuportadas do tipo protocolo, colocadas sob carga imediata, empregando dois sistemas reabilitadores após 7 anos / Clinical and radiographic evaluation of implants used to support mandibular complete full-arch fixed prosthesis employing two rehabilitation systems with immediate loading after 7 years

Karen Vaz Ayub 04 October 2013 (has links)
Esta pesquisa avaliou o sucesso de implantes utilizados como pilares de próteses inferiores implantossuportada do tipo protocolo, empregando dois sistemas reabilitadores, sob carga imediata, após 7 anos. Foram pesquisados os seguintes aspectos: índices de placa e de sangramento, estabilidade dos implantes por frequência de ressonância (FR) e perda óssea marginal. Foram avaliados 76 implantes, em 19 pacientes, divididos em 2 grupos: A (n=12, All-on-four® - Nobel Biocare®) e B (n=7, Neopronto® - Neodent®). Os pacientes foram acompanhados nos momento da instalação dos implantes (inicial), 6 meses, 1, 2 e 7 anos após a instalação. Os resultados mostraram uma taxa de sucesso de 100% para os implantes do grupo A e de 90% para o grupo B. Os índices de placa não apresentaram diferenças estatisticamente significativas e foram, no grupo A, de 71,87%, 63,54% e 47,92%, e, no grupo B de 26,78%, 41,07% e 37,50%, para as avaliações de 1, 2 e 7 anos, respectivamente. O índice de sangramento para o grupo A foi de 43,75%, 42,71% e 43,75% e para o grupo B foi de 53,57%, 51,79% e 48,21%, nos tempos de avaliação de 1, 2 e 7 anos, respectivamente, sem diferenças estatísticas. Não foi observado supuração em nenhum tempo de avaliação. Os resultados de FR não diferiram estatísticamente entre os dois grupos, entretanto, diminuíram entre a avaliação inical (grupo A = 69,27ISQ e grupo B = 68,29ISQ) e de 6 meses (grupo A = 64,65ISQ e grupo B = 66,50ISQ), e aumentaram nos anos seguintes para os 2 grupos, sendo para o grupo A de 66,17ISQ, 66,05ISQ e 69,87ISQ e para o grupo B de 67,78ISQ, 68,13ISQ e 73,61ISQ para os tempos de 1, 2 e 7 anos, respectivamente. Em relação a perda óssea, existiu diferença significativa entre grupos e foi de 0,49mm e 0,67mm após 1 ano e de 1,03mm e 1,27mm, após 7 anos, para os grupos A e B, respectivamente. Em relação à posição dos implantes, o grupo B apresentou diferença estatística entre os implantes centrais e distais nas avaliações de FR e perda óssea. Concluiu-se que 1- a taxa de sucesso foi de 100% para o grupo A e de 90% para o grupo B; 2- os índices de placa e de sangramento diminuíram ao longo dos anos de avaliação; 3- a FR foi semelhante entre os grupos, mas com diferença significativa no grupo A para o critério tempo e, no grupo B para os critérios tempos de avaliação e posição dos implantes; 4- perda da altura da crista óssea foi diferente significativamente entre os grupos, sendo maior no grupo B. / This study evaluated the success of implants used to support mandibular complete full-arch fixed prosthesis employing two rehabilitation systems with immediate loading after 7 years. The following aspects were investigated: plaque and bleeding index, implant stability by resonance frequency analysis and marginal bone loss. The 76 implants were evaluated in 19 patients divided in 2 groups: A (n=12, All-on-four® - Nobel Biocare®) and B (n=7, Neopronto® - Neodent®). The follow-up visits were at the time of implant placement (initial), 6 months, 1, 2 and 7 years after surgery. The results showed a success rate of 100% for implants in group A and 90% for group B. The plaque index did not differ statistically signifcant and were in group A, 71.87%, 63.54% and 47.92%, and in group B 26.78%, 41.07% and 37, 50% for 1, 2 and 7 years of follow-up, respectively. The bleeding index for group A was 43.75%, 42.71% and 43.75% and for group B was 53.57%, 51.79% and 48.21%, for 1, 2 and 7 years of follow-up, respectively, no statistical differences. Suppuration was not observed at any time of evaluation. The results of FR did not differ significantly between groups, however, decreased between initial (group A = 69,27ISQ and group B = 68,29 ISQ) and 6 months (group A = 64,65ISQ and group B = 66,50ISQ), and increased in the following evaluations for both groups, in group A was 66,17ISQ, 66,05ISQ and 69,87ISQ and group B was 67,78ISQ, 68,13ISQ and 73,61ISQ for 1, 2 and 7 years of follow-up, respectively. In relation to bone loss, a significant difference existed between groups and was 0,49mm and 0,67 mm after 1 year and 1,03mm and 1,27mm after 7 years, for groups A and B, respectively. Regarding the position of the implants, group B showed statistical difference between the central and distal implants for FR and bone loss. It was concluded that 1- Success rate was 100% for group A and 90% for group B; 2 - Plaque and bleeding index decreased over the follow-up; 3- FR was similar between groups, but with a significant difference in group A for thw criterion time, and in group B for the criteria evaluation times and position of the implants, 4- bone loss was significantly different between groups, and higher in group B.
5

Correlação da tensão no intermediário e as medidas de comprimento, altura e angulação de infraestruturas de próteses sobre implantes / Correlation of abutment tension and measures of length, height and angle of implant-supported prostheses framework

Fernanda Furtado Piras 28 May 2015 (has links)
A adaptação passiva e estabilidade têm sido descritos como pré-requisitos importantes na escolha dos materiais e técnicas de confecção em prótese implantossuportada. A proposta deste trabalho foi estudar, com auxílio dos strain gauges, a deformação média gerada nos intermediários após a aplicação de carga axial em infraestruturas confeccionadas por três diferentes materiais. Além disso, através da microscopia confocal a laser, avaliar as medidas de comprimento, altura e angulação desses espécimes e mini pilares. Esses dados foram submetidos à análise estatística, a fim de encontrar possível correlação entre a deformação gerada e as medidas internas das infraestruturas com as externas dos intermediários em que foram parafusadas. Para essa investigação foi utilizado um modelo em poliuretano com dois implantes, hexágono externo, posicionados nas áreas dos dentes 43 e 45. A partir deste modelo, 12 infraestruturas de três elementos foram fabricadas e divididas em 3 grupos (n=4) de acordo com a técnica utilizada: (C) fundição convencional em Ni-Cr; (U) usinada em zircônia por CAD/CAM e (S) sinterizada a laser em Co-Cr pelo CAD/CAM. Durante a aplicação de carga axial, as tensões geradas foram registradas por extensômetros unidos aos intermediários, e avaliadas quantitativamente e qualitativamente. De maneira geral, houve um predomínio de áreas de compressão, sendo que as poucas áreas de tração apresentaram baixos valores. O grupo sinterizado a laser foi o único que apresentou forças compressivas para todos os sensores. Os grupos usinado e convencional apresentaram comportamento semelhante, diferindo apenas em uma região. Posteriormente, as infraestruturas e os intermediários foram submetidos à microscopia confocal para avaliação de ângulo, comprimento e altura de suas paredes internas (infraestruturas) e externas (intermediários), nas regiões correspondentes à localização dos strain gauges. Para a angulação, todos os grupos mostraram valores semelhantes entre si e maiores que os dos mini pilares. Quanto ao comprimento e altura, todos valores foram diferentes entre si. Em relação aos mini pilares, os valores foram maiores na altura e menores no comprimento. Estes resultados foram analisados pelo método estatístico de Pearson o que levou à conclusão que, para algumas regiões dos medidores de tensão, há correlação entre deformação e comprimento, e também, deformação e ângulo. Quanto maior o ângulo, e quanto menor for o comprimento, maior a deformação mostrada. / The passive adaptation and stability have been described as important prerequisites in the choice of materials and manufacturing techniques in implant-supported prosthesis. The aim of this work was to study, with the aid of strain gauges, the average deformation generated in the abutment, after application of axial load on frameworks made up of three different materials. Besides, through confocal laser microscopy, assess the length, height, and angle of these specimens, and abutment. These data were statistically analyzed in order to find possible correlation between the deformation generated, and the internal measures of the framework and the external measure of the abutments they were screwed on. For this research, a model made of polyurethane with two external hexagon implants, positioned in the areas of teeth 43 and 45 was used. From this model, 12 three-element frameworks were fabricated and divided into 3 groups (n = 4), according to the technique used: (C) conventional Ni-Cr casting; (U) machined zirconia CAD / CAM and (S) laser sintered Co-Cr by CAD / CAM. During application of axial load, the tensions generated were recorded by strain gauges attached to the abutments, and evaluated quantitatively and qualitatively. In general, there was a predominance of compression areas, and the few areas of traction showed low values. The laser sintered group was the only one with compressive forces for all sensors. The milled and conventional groups behaved similarly, differing only in a region. Subsequently, the framework and the abutment were analyzed by confocal microscopy for evaluation of angle, length and height of the inner (framework) and outer (abutment) walls in regions corresponding to the location of strain gauges. For the variable angle, all groups showed similar values among themselves and greater than the abutments. As for the variables length and height, all values were different. Regarding the abutments, the values were higher in height and smaller in length. These results were analyzed by Pearson statistical method, leading to the conclusion that, for some regions, there was correlation between deformation and length, and also deformation and angle. The higher the angle and the smaller the length, the greater the deformation shown.
6

Avaliação da precisão da adaptação de próteses sobre implantes, fundidas em monobloco, com ligas de Ni-Cr e Co-Cr e em Ti cp, antes e após soldagem a laser e após a simulação da aplicação de cerâmica / Evaluation of the precision of fit of one-piece implant-retained and supported prostheses cast in Ni-Cr and Co-Cr alloys and Cp Ti, before and after laser welding and after simulated porcelain firing cycles

Tiossi, Rodrigo 26 May 2006 (has links)
O objetivo deste estudo foi avaliar o assentamento passivo de supra-estruturas de próteses fixas implanto-suportadas de três elementos, fundidas em titânio comercialmente puro e em ligas à base de Ni-Cr e Co-Cr. Para esta análise foi utilizado o método de Sheffield (EISENMAN, 1997), e as leituras foram realizadas num microscópio óptico comparador (Nikon, Japão). Foram utilizados dois implantes de hexágono interno Master Conect AR (Conexão Sistemas de Prótese, Brasil). Os dados foram submetidos à análise de variância (ANOVA) e também ao teste complementar de Tukey-Kramer. A análise dos dados permitiu concluir que: as interfaces, quando os três grupos foram analisados em monobloco e com os dois parafusos apertados, foram mais satisfatórias para o grupo fundido em liga de Ni-Cr (25,00 ± 7,92μm), apesar deste grupo não ser estatisticamente diferente dos outros dois (Co-Cr: 54,23 ± 37,10μm e Ti cp: 48,41 ± 26,69μm). No teste do parafuso único os três grupos também foram estatisticamente iguais, com os seguintes resultados, no lado parafusado: Co-Cr: 35,01 ± 27,76μm, Ni-Cr: 20,13 ± 7,97μm, e Ti cp: 22,28 ± 17,29μm, e no lado contrário: Co-Cr: 118,64 ± 91,48μm, Ni-Cr: 70,66 ± 20,88μm, e Ti cp: 118,56 ± 51,35μm. Neste mesmo estudo também se realizou a secção das peças e posterior soldagem a laser. A soldagem foi conduzida na máquina Desktop Laser (Dentaurum, Alemanha). A análise do assentamento passivo foi novamente realizada pelo método de Sheffield e as leituras foram feitas no microscópio óptico comparador (Nikon). O procedimento de separação das peças em monobloco e posterior soldagem a laser resultou em diminuição estatisticamente significante nos níveis de desajuste quando analisadas as peças com os dois parafusos apertados para o grupo fundido em liga de Co-Cr (21,49 ± 9,08μm). Para os outros dois grupos, liga de Ni-Cr (13,10 ± 1,81μm) e Ti cp (17,70 ± 11,70μm), os resultados não apresentaram diferenças estatisticamente significantes, apesar de apresentarem menores níveis de desajuste marginal. No teste do parafuso único e leitura no lado oposto, apenas o grupo fundido em liga de Ni-Cr (19,81 ± 7,36μm) não apresentou diferença estatisticamente significante quando comparado à fundição em monobloco. Os grupos em liga de Co-Cr (41,02 ± 26,15μm) e em Ti cp (40,42 ± 27,14μm) apresentaram diferenças estatisticamente significantes após a soldagem a laser. Na leitura no lado apertado os três grupos foram estatisticamente iguais. A simulação dos ciclos de queima da cerâmica não provocou alterações significativas nas interfaces analisadas sob todas as condições de leitura e aperto dos parafusos. Os grupos fundidos em ligas de Co-Cr e em Ti cp, quando analisados com apenas um parafuso apertado e as leituras realizadas no lado oposto, apresentaram diminuição dos níveis de ajuste, sendo 26,42 ± 8,67μm, após a simulação, quando era 41,02 ± 26,15μm após soldagem a laser para o primeiro e, 40,42 ± 27,14μm e 28,05 ± 20,89μm, antes e após a simulação, para o segundo, porém sem diferenças estatisticamente significantes. / The purpose of this study was to evaluate the precision of fit of three-element implant-retained and supported frameworks, cast in Ni-Cr- and Co-Cr alloys and commercially pure titanium (Cp Ti). The Sheffield´s test (EISENMAN, 1997) was used to analyze the marginal interfaces, and the readings executed in an optic microscope (Nikon, Japan). Two Master Conect AR (Conexão Sistemas de Prótese, Brazil) internal-hexagon implant systems were used. Data were submitted to analysis of variance (ANOVA) with complementary Tukey-Kramer’s test. Data analysis showed that: the interfaces, when analyzed as a one-piece casting and with both screws tightened, were better for the group cast in Ni-Cr alloy (25.00 ± 7.92μm), though not statistically different from the two other groups (Co-Cr: 54.23 ± 37.10μm e Cp Ti: 48.41 ± 26.69μm). In the single screw tightened test the three groups showed no statistical difference, with the following results, on the tightened side: Co-Cr: 35.01 ± 27.76μm, Ni-Cr: 20.13 ± 7.97μm, and Cp Ti: 22.28 ± 17.29μm, and on the opposite side: Co-Cr: 118.64 ± 91.48μm, Ni-Cr: 70.66 ± 20.88μm, and Cp Ti: 118.56 ± 51.35μm. On this same study, the one-piece castings were sectioned and laser welded. The laser welding was executed with the Desktop Laser (Dentaurum, Germany) machine. The Sheffield´s test was used to analyze the passive fit, and the readings executed in an optic microscope (Nikon). The procedure of sectioning the one-piece castings and its later laser welding presented statistically significant lower levels of misfit when the castings were analyzed with both screws tightened for the group cast in Co-Cr alloy (21.49 ± 9.08μm). For the other two groups, Ni-Cr alloy (13.10 ± 1.81μm) and Cp Ti (17.70 ± 11.70μm), results presented no statistically significant differences, though showed lower levels of marginal fit. In the single screw tightened test and readings made on the opposite side, only the group cast on Ni-Cr alloy (19.81 ± 7.36μm) didn’t present statistically significant lower levels of misfit when compared to single-piece castings. The Co-Cr alloy (41.02 ± 26.15μm) and the Cp Ti (40.42 ± 27.14μm) groups showed statistically significant differences after laser welding. The reading on the screwed side detected that the three groups were statistically the same. Simulation of the porcelain firing cycles did not develop any significant differences on the analyzed interfaces under all readings and screw tightening conditions. The groups cast in Co-Cr alloy and Cp Ti, when analyzed with only one screw tightened and the readings executed on the opposite side, presented lower levels of misfit, being 26.42 ± 8.67μm, after simulation, when was 41.02 ± 26.15μm after laser welding for the first and, 40.42 ± 27.14μm and 28.05 ± 20.89μm, before and after, for the second, though not showing any statistically significant differences.
7

Influência dos ciclos de cocção da porcelana na força de destorque de parafusos de estruturas implanto-retidas / Influence of porcelain fire cycles on detorque resistance of screws from implant-retained structures

Torres, José Walter Murta, 1958- 21 August 2018 (has links)
Orientador: Guilherme Elias Pessanha Henriques / Tese (Doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-21T23:50:10Z (GMT). No. of bitstreams: 1 Torres_JoseWalterMurta_D.pdf: 1581851 bytes, checksum: 0bbcce2409164d19a4e51f955b38d595 (MD5) Previous issue date: 2013 / Resumo: Este trabalho avaliou a resistência ao destorque em parafusos de estruturas metálicas implanto-retidas fundidas em níquel-cromo (Ni-Cr) após fundição e simulação dos ciclos de cocção da porcelana. Dois implantes hexágono externo - com 3,75 mm de diâmetro - foram posicionados, com o auxílio de um paralelômetro fresador (1000N; Bio-art), na posição de segundo pré-molar e segundo molar num troquel de resina acrílica, de maneira a ficarem parcialmente submersos na resina expondo apenas suas plataformas de adaptação. Foram confeccionados 10 troqueis de resina acrílica (n=10). A partir de cada troquel foi obtida, pelo método de fundição da cera perdida, uma infraestrutura implanto-retida utilizando-se dois cilindros calcináveis tipo UCLA. A amostra foi submetida à força de torque de seus parafusos de fixação a 20 Ncm, registrada por meio de um torquímetro digital de precisão (Torque Meter TQ-8800; Lutron), e reapertados após 10 minutos. A força de destorque foi registrada após 24 horas do torque inicial. A resistência ao destorque foi analisada após fundição da estrutura protética e simulação dos três ciclos de cocção da porcelana (opaco dentina e glaze). Foram obtidas médias de destorque para cada estrutura nas distintas etapas de avaliação no estudo. Os dados foram analisados estatisticamente pelos testes ANOVA one-way e Bonferroni, com nível de significância de 5% (p<0,05). Os valores das médias da força de destorque dos parafusos por fase foram 13,95 ± 1,12 Ncm para pós-fundição, 15,20 ± 1,18 Ncm para ciclo Opaco, 15,85 ± 1,13 Ncm para ciclo Dentina e 16,80 ± 1,03 Ncm para o glaze. A força de destorque dos parafusos após a fundição foi significativamente menor do que a obtida para os grupos que simularam o ciclo de cocção da porcelana (p<0,05). Entre as fases de simulação dos ciclos cerâmicos, observou-se maior valor da força de destorque para o glaze (p<0,05), não sendo observadas diferenças estatisticamente significantes entre as fases opaco e dentina (p>0,05). Foi possível verificar que os ciclos de cocção da porcelana influenciam a resistência ao destorque em parafusos de estruturas metálicas implanto-retidas fundidas em níquel-cromo (Ni-Cr). Observou-se que os valores de destorque aumentaram gradativamente com cada ciclo de cocção da porcelana / Abstract: This study evaluated the resistance to detorque of screws from implant-retained metal structures cast in nickel-chromium (Ni-Cr) after metal casting and simulation of porcelain firing cycle. Two external hex implants - with 3.75 mm diameters - were placed with the help of a parallelometer cutter (1000N; Bio-art), in the position of second premolar and second molar in acrylic resin die, so as to be partially submerged in the resin exposing only their platforms for adaptation. Thereupon, 10 dies were made with acrylic resin (n= 10). An implant-retained infrastructure from each die was obtained by the method of lost wax casting, using two UCLA cylinders. The sample of acrylic structures were subjected to 20 Ncm of torque to its fixing screws registered by means of a precision digital torque wrench (Torque Meter TQ-8800; Lutron) and retightened after 10 minutes. The measure of detorque was recorded 24 hours after the initial torque. The detorque resistance was analyzed after denture casting, followed by the simulation of porcelain firing cycles (opaque, dentin and glaze). Detorque averages were obtained for each structure at different stages of evaluation in this study. Data was statistically analyzed by one-way ANOVA and Bonferroni tests, at 5% significance level (p>0.05). We performed necessary statistical tests. The mean detorque force of the screws per phase were 13.95 ± 1.12 Ncm for post-casting; 15.20 ± 1.18 Ncm for cycle opaque; 15.85 ± 1.13 Ncm for cycle dentin; and 16.80 ± 1.03 Ncm for glazing. The screw's post-casting detorque resistance was significantly lower than that observed for the groups simulating porcelain firing cycles (p<0.05). Among groups simulating ceramic's cycles, the highest detorque resistance was observed for glaze group (p<0.05), with no significant statistical differences among opaque and dentin groups (p>0.05). It was possible that the porcelain firing cycle influenced detorque resistance of screws in implant-retained metal structures cast in nickel-chromium (Ni-Cr). It was observed that detorque values gradually increased after each porcelain firing cycle / Doutorado / Protese Dental / Doutor em Clínica Odontológica
8

Avaliação da precisão da adaptação de próteses sobre implantes, fundidas em monobloco, com ligas de Ni-Cr e Co-Cr e em Ti cp, antes e após soldagem a laser e após a simulação da aplicação de cerâmica / Evaluation of the precision of fit of one-piece implant-retained and supported prostheses cast in Ni-Cr and Co-Cr alloys and Cp Ti, before and after laser welding and after simulated porcelain firing cycles

Rodrigo Tiossi 26 May 2006 (has links)
O objetivo deste estudo foi avaliar o assentamento passivo de supra-estruturas de próteses fixas implanto-suportadas de três elementos, fundidas em titânio comercialmente puro e em ligas à base de Ni-Cr e Co-Cr. Para esta análise foi utilizado o método de Sheffield (EISENMAN, 1997), e as leituras foram realizadas num microscópio óptico comparador (Nikon, Japão). Foram utilizados dois implantes de hexágono interno Master Conect AR (Conexão Sistemas de Prótese, Brasil). Os dados foram submetidos à análise de variância (ANOVA) e também ao teste complementar de Tukey-Kramer. A análise dos dados permitiu concluir que: as interfaces, quando os três grupos foram analisados em monobloco e com os dois parafusos apertados, foram mais satisfatórias para o grupo fundido em liga de Ni-Cr (25,00 ± 7,92&#956;m), apesar deste grupo não ser estatisticamente diferente dos outros dois (Co-Cr: 54,23 ± 37,10&#956;m e Ti cp: 48,41 ± 26,69&#956;m). No teste do parafuso único os três grupos também foram estatisticamente iguais, com os seguintes resultados, no lado parafusado: Co-Cr: 35,01 ± 27,76&#956;m, Ni-Cr: 20,13 ± 7,97&#956;m, e Ti cp: 22,28 ± 17,29&#956;m, e no lado contrário: Co-Cr: 118,64 ± 91,48&#956;m, Ni-Cr: 70,66 ± 20,88&#956;m, e Ti cp: 118,56 ± 51,35&#956;m. Neste mesmo estudo também se realizou a secção das peças e posterior soldagem a laser. A soldagem foi conduzida na máquina Desktop Laser (Dentaurum, Alemanha). A análise do assentamento passivo foi novamente realizada pelo método de Sheffield e as leituras foram feitas no microscópio óptico comparador (Nikon). O procedimento de separação das peças em monobloco e posterior soldagem a laser resultou em diminuição estatisticamente significante nos níveis de desajuste quando analisadas as peças com os dois parafusos apertados para o grupo fundido em liga de Co-Cr (21,49 ± 9,08&#956;m). Para os outros dois grupos, liga de Ni-Cr (13,10 ± 1,81&#956;m) e Ti cp (17,70 ± 11,70&#956;m), os resultados não apresentaram diferenças estatisticamente significantes, apesar de apresentarem menores níveis de desajuste marginal. No teste do parafuso único e leitura no lado oposto, apenas o grupo fundido em liga de Ni-Cr (19,81 ± 7,36&#956;m) não apresentou diferença estatisticamente significante quando comparado à fundição em monobloco. Os grupos em liga de Co-Cr (41,02 ± 26,15&#956;m) e em Ti cp (40,42 ± 27,14&#956;m) apresentaram diferenças estatisticamente significantes após a soldagem a laser. Na leitura no lado apertado os três grupos foram estatisticamente iguais. A simulação dos ciclos de queima da cerâmica não provocou alterações significativas nas interfaces analisadas sob todas as condições de leitura e aperto dos parafusos. Os grupos fundidos em ligas de Co-Cr e em Ti cp, quando analisados com apenas um parafuso apertado e as leituras realizadas no lado oposto, apresentaram diminuição dos níveis de ajuste, sendo 26,42 ± 8,67&#956;m, após a simulação, quando era 41,02 ± 26,15&#956;m após soldagem a laser para o primeiro e, 40,42 ± 27,14&#956;m e 28,05 ± 20,89&#956;m, antes e após a simulação, para o segundo, porém sem diferenças estatisticamente significantes. / The purpose of this study was to evaluate the precision of fit of three-element implant-retained and supported frameworks, cast in Ni-Cr- and Co-Cr alloys and commercially pure titanium (Cp Ti). The Sheffield´s test (EISENMAN, 1997) was used to analyze the marginal interfaces, and the readings executed in an optic microscope (Nikon, Japan). Two Master Conect AR (Conexão Sistemas de Prótese, Brazil) internal-hexagon implant systems were used. Data were submitted to analysis of variance (ANOVA) with complementary Tukey-Kramer’s test. Data analysis showed that: the interfaces, when analyzed as a one-piece casting and with both screws tightened, were better for the group cast in Ni-Cr alloy (25.00 ± 7.92&#956;m), though not statistically different from the two other groups (Co-Cr: 54.23 ± 37.10&#956;m e Cp Ti: 48.41 ± 26.69&#956;m). In the single screw tightened test the three groups showed no statistical difference, with the following results, on the tightened side: Co-Cr: 35.01 ± 27.76&#956;m, Ni-Cr: 20.13 ± 7.97&#956;m, and Cp Ti: 22.28 ± 17.29&#956;m, and on the opposite side: Co-Cr: 118.64 ± 91.48&#956;m, Ni-Cr: 70.66 ± 20.88&#956;m, and Cp Ti: 118.56 ± 51.35&#956;m. On this same study, the one-piece castings were sectioned and laser welded. The laser welding was executed with the Desktop Laser (Dentaurum, Germany) machine. The Sheffield´s test was used to analyze the passive fit, and the readings executed in an optic microscope (Nikon). The procedure of sectioning the one-piece castings and its later laser welding presented statistically significant lower levels of misfit when the castings were analyzed with both screws tightened for the group cast in Co-Cr alloy (21.49 ± 9.08&#956;m). For the other two groups, Ni-Cr alloy (13.10 ± 1.81&#956;m) and Cp Ti (17.70 ± 11.70&#956;m), results presented no statistically significant differences, though showed lower levels of marginal fit. In the single screw tightened test and readings made on the opposite side, only the group cast on Ni-Cr alloy (19.81 ± 7.36&#956;m) didn’t present statistically significant lower levels of misfit when compared to single-piece castings. The Co-Cr alloy (41.02 ± 26.15&#956;m) and the Cp Ti (40.42 ± 27.14&#956;m) groups showed statistically significant differences after laser welding. The reading on the screwed side detected that the three groups were statistically the same. Simulation of the porcelain firing cycles did not develop any significant differences on the analyzed interfaces under all readings and screw tightening conditions. The groups cast in Co-Cr alloy and Cp Ti, when analyzed with only one screw tightened and the readings executed on the opposite side, presented lower levels of misfit, being 26.42 ± 8.67&#956;m, after simulation, when was 41.02 ± 26.15&#956;m after laser welding for the first and, 40.42 ± 27.14&#956;m and 28.05 ± 20.89&#956;m, before and after, for the second, though not showing any statistically significant differences.
9

Estudo biomecânico de conexões implante/pilar com parafusos convencionais e parafusos modificados tipo Cone Morse: análise tridimensional pelo método dos elementos finitos / Biomechanical study of implant/abutment connections with conventional screws and modified Morse Taper screws: three-dimensional analysis by finite element method.

Pita, Murillo Sucena 19 April 2013 (has links)
Apesar da confiabilidade e das altas taxas de sucesso relacionadas aos tratamentos com implantes, falhas das reabilitações protéticas ainda são persistentes, especialmente o afrouxamento dos parafusos de retenção dos pilares. A aplicação de um torque, que gere uma pré-carga no mesmo, tem sido o seu principal meio de prevenção, embora não tenha sido capaz de eliminá-lo completamente. A natureza do afrouxamento é complexa, e os mecanismos responsáveis pelas falhas mecânicas dos parafusos de conexão dos sistemas de implantes não estão totalmente elucidados. Modificações nos modelos das conexões protéticas e dos parafusos de retenção vêm sendo desenvolvidas com o intuito de resolver essa intercorrência. Porém, a literatura relativa à configuração ideal destas modificações biomecânicas e seus fatores determinantes envolvidos ainda é inconclusiva. Assim, o objetivo do presente do estudo foi avaliar por meio da análise tridimensional de elementos finitos, a distribuição de tensões em dois diferentes sistemas de implantes, hexágono externo (HE) e triângulo interno (TI), com parafusos de retenção de pilares planos convencionais e parafusos modificados tipo Cone Morse, estabelecendo-se qualitativamente os mapas de tensões e quantitativamente os valores de pré-carga diante do torque e de carregamentos axiais e oblíquos pré-estabelecidos. Os resultados evidenciaram que, para todos os modelos, os carregamentos externos não exerceram influência sobre os valores das tensões de von Mises e da pré-carga, e que as tensões mais elevadas concentraram-se especificamente na haste dos parafusos. A conexão TI apresentou-se biomecanicamente mais favorável do que a conexão HE, com distribuição mais homogênea de tensões ao longo do conjunto implante/pilar/parafuso. Adicionalmente, os parafusos planos convencionais apresentaram, significativamente, menores tensões e valores de pré-carga superiores aos parafusos modificados tipo Cone Morse, portanto estes últimos revelaram-se mais susceptíveis a falhas mecânicas como o afrouxamento e/ou fratura. / Despite the reliability and high success rates related to treatment with implants, prosthetic rehabilitation failures are still persistent, especially the loosening of the screws holding the abutments. Applying a torque, which generates a preload on the screw, has been its primary means of prevention, although not being able to eliminate it completely. The nature of loosening is complex, and the mechanisms responsible for mechanical failure of the screw connecting the implant systems are not fully elucidated. Changes in designs of connections and prosthetic retaining screws have been developed in order to solve this complication. However, the literature on the optimal configuration of these changes and their biomechanical factors involved is still inconclusive. The objective of this study was to evaluate through three-dimensional finite element analysis, the stress distribution in two different implant systems, external hexagon (EH) and internal triangle (IT), with conventional plan screws and modified Morse Taper screws, establishing up qualitatively the stress maps and quantitatively the values of preload in front of the torque and of pre-established axial and oblique loads. The results showed that, for all models, the external loads exerted no influence on the values of von Mises stress and preload, and that the higher stresses have focused specifically on the spindle of the screws. The IT connection appeared biomechanically more favorable than the EH, with more homogeneous distribution of stresses throughout the whole implant/abutment/screw. Additionally, conventional screws showed significantly lower stress values and higher preload than the modified Morse Taper screws, then, this latter proved to be more susceptible to mechanical failures as loosening and/or fracture.
10

Avaliação in vitro da infiltração bacteriana na interface implante/componente protético em conexões dos tipos cone morse e hexágono interno / In vitro evaluation of bacterial leakage at the implant abutment interface in types of connections Morse Taper and Internal Hexagon

Teixeira, Wendel 03 September 2009 (has links)
A precisão na fabricação de um implante pode ser verificada pelo grau de adaptação na interface implante/componente protético. Uma pobre adaptação permite a infiltração de microrganismos através dessa interface e a colonização dos espaços vazios dos implantes, levando ao surgimento de reações inflamatórias dos tecidos periimplantares e ao insucesso clínico do tratamento. O objetivo deste trabalho foi avaliar, in vitro, a infiltração de uma bactéria, o Staphylococcus aureus, através da interface implante/componente protético, pelo método de cultura bacteriana. Foram utilizados vinte conjuntos de implantes Cone Morse, com os Pilares CM (NEODENT®, Curitiba, Paraná, Brasil), divididos em dois grupos: Grupo A, onde foram avaliados quanto à infiltração bacteriana de fora para dentro dos implantes, e Grupo B, onde foram avaliados quanto à infiltração bacteriana de dentro para fora dos implantes. Foram utilizados também vinte conjuntos de implantes Titamax II Plus, com os Mini Pilares Cônicos II Plus (NEODENT®, Curitiba, Paraná, Brasil), divididos em dois grupos: Grupo C, onde foram avaliados quanto à infiltração bacteriana de fora para dentro dos implantes, e Grupo D, onde foram avaliados quanto à infiltração bacteriana de dentro para fora dos implantes. Na avaliação da infiltração bacteriana de dentro para fora dos implantes, foi feita a inoculação da bactéria na parte interna dos implantes, e estes mergulhados em tubos de ensaio contendo um meio de enriquecimento estéril. Para avaliação da infiltração bacteriana de fora para dentro dos implantes, os conjuntos implantes/componentes foram mergulhados em tubos de ensaio contendo um meio de enriquecimento com cepas da bactéria. Ocorreu infiltração bacteriana em todos os grupos, e não houve diferença estatisticamente significante entre os grupos A e C, nem entre os grupos B e D, em relação à percentagem da passagem do microrganismo na interface implante/componente protético. / The precision in the manufacture of an implant can be determined by the degree of adaptation at the abutment-implant interface. A poor adaptation allows the infiltration of microorganisms through this interface and colonization of empty spaces of the implants, leading to inflammatory reactions and clinical failure of treatment. The aim of the present in-vitro study was to investigate leakage of Staphylococcus aureus through the abutment-implant interface, by the method of bacterial culture. It was used twenty sets of Morse Taper implants with Pillars CM (NEODENTTM, Curitiba, Paraná, Brazil), divided into two groups: Group A, which were evaluated for bacterial infiltration into the inner part of the implants, and Group B, which were evaluated for bacterial infiltration from the inner part of the implants. Were also used twenty sets of Titamax II Plus implants, with the conical Mini Pillars II Plus (NEODENTTM, Curitiba, Paraná, Brazil), divided into two groups: Group C, which were evaluated for bacterial infiltration into the inner part of the implants and Group D, which were evaluated for bacterial infiltration from the inner part of the implants. In the evaluation of bacterial infiltration from the implants, the assemblies had the inner parts inoculated with S. aureus, and each assembly was incubated in BHI broth. For assessment of bacterial leakage into the implants, each assembly was submerged in S. aureus culture in tubes. Bacterial infiltration occurred in all groups, and there was no statistically significant difference between groups A and C, or between groups B and D.

Page generated in 0.1114 seconds