• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 18
  • 1
  • Tagged with
  • 19
  • 19
  • 19
  • 19
  • 17
  • 15
  • 15
  • 15
  • 15
  • 15
  • 12
  • 7
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo de dois sistemas de reabilitação com implantes submetidos à ativação imediata: análise clínica, radiográfica e da estabilidade, por frequência de ressonância / Study of two rehabilitation systems with dental implants submitted to immediate loading: clinical and radiographic evaluations, and stability using resonance frequency analysis

Ayub, Eduardo Antonio 28 August 2007 (has links)
Avaliou-se o comportamento biomecânico, quanto à área de estabilidade protética, extensão de cantilever e estabilidade por análise freqüência de ressonância (AFR); parâmetros clínicos: índice de placa (IP), índice de sangramento (IS), supuração, distância da plataforma do implante-margem da mucosa (DPM), profundidade de sondagem (PS), nível de inserção (NI), sangramento à sondagem (SS), largura (LM), espessura (EM) da mucosa e análise radiográfica, em dois sistemas de reabilitações implanto-suportadas. Foram instalados 104 implantes, submetidos à ativação imediata, em 26 pacientes, divididos em dois grupos: A (n= 16, All-on-4®-Nobel Biocare) e B (n=10, Neopronto®-Neodent). As próteses foram instaladas em tempo médio de 32h. (T0), e controles realizados em seis (T6), doze (T12) e 24 meses (T24). Como resultado, a taxa de sucesso foi de 100% para o grupo A e 90% para o grupo B para implantes e próteses. Diferenças significantes (p<0,05) foram apresentadas entre o cantilever posterior 10,96mm e 18,81mm e o braço de resistência (BR) 13,87mm e 5,50mm, respectivamente para os grupos A e B. A área de estabilidade, no grupo A foi de 373,5mm2 e no B de 112,8mm2; a média da AFR (em ISQ) do grupo A T0= 68,62; T6=64,40; T12=67,07; T24=66,53 e do grupo B T0= 68,37; T6=66,29; T12=67,09; T24=67,10, com diferenças (p<0,05) entre os tempos (grupo A) e posição dos implantes (grupo B). O IP no grupo A=1,0 e 0,7; grupo B=0,6 e 0,9, o IS (0,7), supuração (ausente) e SS (presença) no grupo A=50% e 37,9%; grupo B=70,1 e 52,1%, no controle de 12 e 24 meses, não mostraram diferenças estatísticas entre os grupos. As médias (em mm) da LM para o grupo A (2,05 e 2,21) e B (2,29 e 2,40) e EM grupo A (1,53 e 1,56) e B (1,31 e 1,43), DPM do grupo A (2,54e 2,52) e B (0,18mm e -0,12mm), PS grupo A (3,52 e 3,52) e B (3,52 e 4,0), NI grupo A (0,98 e 0,99) e B (3,05 e 3,57) e perda óssea grupo A (0,45mm e 0,23mm ) grupo B(0,66mm e 0,22mm), respectivamente para 12 e 24 meses, apresentaram diferenças estatísticas entre os controles. Concluindo-se que 1- O grupo A apresentou área de estabilidade e extensão de cantilever anterior e posterior, com comportamento biomecânico mais favorável do que no grupo B; 2- A estabilidade primária e secundária (AFR) foi diferente entre os tempos (grupo A) e posição dos implantes (grupo B), mas semelhantes entre os grupos; 3- Os parâmetros clínicos de índice de placa, sangramento marginal, supuração, profundidade de sondagem (exceto para os períodos de controle no grupo B), sangramento a sondagem, largura e espessura de mucosa ceratinizada foram semelhantes entre os grupos; 4- A distância da plataforma do implante-margem da mucosa foi maior no grupo A e o nível de inserção foi maior no grupo B; 5- A perda na altura da crista óssea foi semelhante entre os grupos; 6- A perda óssea foi menor nos implantes anteriores do que nos posteriores, nos grupos. / Two implant-supported rehabilitation systems were evaluated considering their biomechanical behavior, the area of prosthetic stability, cantilever extensions, stability using resonance frequency analysis (RFA) and clinical parameters, such as: modified plaque index (PI), modified bleeding index (BI), suppuration, distance between the implant shoulder and the mucosal margin (DIM), probing pocket depth (PD), probing attachment level (PAL), bleeding on probing (BP), thickness (TM) width (WM) of keratinized mucosa and radiographic analysis. One hundred and four implants had been installed in twenty six patients, submitted to immediate loading and divided into two groups: A (n=16, All-on-4®-Nobel Biocare) e B (n=10, Neopronto®-Neodent). The prosthesis had been installed in average time of 32h (T0), and controls made in (T6), 12 (T12) and 24 months (T24). As result, the success rate was 100% for the group A and 90% for the group B for both implants and prosthesis. Significant differences (p<0,05) 10,96mm and 18,81mm had been presented between posterior cantilever and the resistance arm (RA) 13,87mm and 5,50mm, respectively for the groups A and B. The stability area, in the group A was of 373,5mm2 and in B of 112,8mm2; the average of RFA (in ISQ) of the group A T0= 68,62; T6=64,40; T12=67,07; T24=66,53 and of the group B T0= 68,37; T6=66,29; T12=67,09; T24=67,10, with differences (p<0,05) between the periods (Group A) and implant position (Group B). The PI in group A was of 1,0 and 0,7 and 0,6 and 0,9 for group B, o BI (0,7), suppuration (absent), DP (presence) in group A=50% and 37,9%; group B=70,1 and 52,1%, in the control of 12 and 24 months, did not present statistical differences between the groups. The average (in mm) of WM for the group A (2,05 and 2,21) and B (2,29 and 2,40) and TM group A (1,53 and 1,56) and B (1,31 and 1,43), DIM of group A (2,54 and 2,52) and B (0,18mm and -0,12mm), DP group.
12

Estudo biomecânico de conexões implante/pilar com parafusos convencionais e parafusos modificados tipo Cone Morse: análise tridimensional pelo método dos elementos finitos / Biomechanical study of implant/abutment connections with conventional screws and modified Morse Taper screws: three-dimensional analysis by finite element method.

Murillo Sucena Pita 19 April 2013 (has links)
Apesar da confiabilidade e das altas taxas de sucesso relacionadas aos tratamentos com implantes, falhas das reabilitações protéticas ainda são persistentes, especialmente o afrouxamento dos parafusos de retenção dos pilares. A aplicação de um torque, que gere uma pré-carga no mesmo, tem sido o seu principal meio de prevenção, embora não tenha sido capaz de eliminá-lo completamente. A natureza do afrouxamento é complexa, e os mecanismos responsáveis pelas falhas mecânicas dos parafusos de conexão dos sistemas de implantes não estão totalmente elucidados. Modificações nos modelos das conexões protéticas e dos parafusos de retenção vêm sendo desenvolvidas com o intuito de resolver essa intercorrência. Porém, a literatura relativa à configuração ideal destas modificações biomecânicas e seus fatores determinantes envolvidos ainda é inconclusiva. Assim, o objetivo do presente do estudo foi avaliar por meio da análise tridimensional de elementos finitos, a distribuição de tensões em dois diferentes sistemas de implantes, hexágono externo (HE) e triângulo interno (TI), com parafusos de retenção de pilares planos convencionais e parafusos modificados tipo Cone Morse, estabelecendo-se qualitativamente os mapas de tensões e quantitativamente os valores de pré-carga diante do torque e de carregamentos axiais e oblíquos pré-estabelecidos. Os resultados evidenciaram que, para todos os modelos, os carregamentos externos não exerceram influência sobre os valores das tensões de von Mises e da pré-carga, e que as tensões mais elevadas concentraram-se especificamente na haste dos parafusos. A conexão TI apresentou-se biomecanicamente mais favorável do que a conexão HE, com distribuição mais homogênea de tensões ao longo do conjunto implante/pilar/parafuso. Adicionalmente, os parafusos planos convencionais apresentaram, significativamente, menores tensões e valores de pré-carga superiores aos parafusos modificados tipo Cone Morse, portanto estes últimos revelaram-se mais susceptíveis a falhas mecânicas como o afrouxamento e/ou fratura. / Despite the reliability and high success rates related to treatment with implants, prosthetic rehabilitation failures are still persistent, especially the loosening of the screws holding the abutments. Applying a torque, which generates a preload on the screw, has been its primary means of prevention, although not being able to eliminate it completely. The nature of loosening is complex, and the mechanisms responsible for mechanical failure of the screw connecting the implant systems are not fully elucidated. Changes in designs of connections and prosthetic retaining screws have been developed in order to solve this complication. However, the literature on the optimal configuration of these changes and their biomechanical factors involved is still inconclusive. The objective of this study was to evaluate through three-dimensional finite element analysis, the stress distribution in two different implant systems, external hexagon (EH) and internal triangle (IT), with conventional plan screws and modified Morse Taper screws, establishing up qualitatively the stress maps and quantitatively the values of preload in front of the torque and of pre-established axial and oblique loads. The results showed that, for all models, the external loads exerted no influence on the values of von Mises stress and preload, and that the higher stresses have focused specifically on the spindle of the screws. The IT connection appeared biomechanically more favorable than the EH, with more homogeneous distribution of stresses throughout the whole implant/abutment/screw. Additionally, conventional screws showed significantly lower stress values and higher preload than the modified Morse Taper screws, then, this latter proved to be more susceptible to mechanical failures as loosening and/or fracture.
13

Avaliação in vitro da infiltração bacteriana na interface implante/componente protético em conexões dos tipos cone morse e hexágono interno / In vitro evaluation of bacterial leakage at the implant abutment interface in types of connections Morse Taper and Internal Hexagon

Wendel Teixeira 03 September 2009 (has links)
A precisão na fabricação de um implante pode ser verificada pelo grau de adaptação na interface implante/componente protético. Uma pobre adaptação permite a infiltração de microrganismos através dessa interface e a colonização dos espaços vazios dos implantes, levando ao surgimento de reações inflamatórias dos tecidos periimplantares e ao insucesso clínico do tratamento. O objetivo deste trabalho foi avaliar, in vitro, a infiltração de uma bactéria, o Staphylococcus aureus, através da interface implante/componente protético, pelo método de cultura bacteriana. Foram utilizados vinte conjuntos de implantes Cone Morse, com os Pilares CM (NEODENT®, Curitiba, Paraná, Brasil), divididos em dois grupos: Grupo A, onde foram avaliados quanto à infiltração bacteriana de fora para dentro dos implantes, e Grupo B, onde foram avaliados quanto à infiltração bacteriana de dentro para fora dos implantes. Foram utilizados também vinte conjuntos de implantes Titamax II Plus, com os Mini Pilares Cônicos II Plus (NEODENT®, Curitiba, Paraná, Brasil), divididos em dois grupos: Grupo C, onde foram avaliados quanto à infiltração bacteriana de fora para dentro dos implantes, e Grupo D, onde foram avaliados quanto à infiltração bacteriana de dentro para fora dos implantes. Na avaliação da infiltração bacteriana de dentro para fora dos implantes, foi feita a inoculação da bactéria na parte interna dos implantes, e estes mergulhados em tubos de ensaio contendo um meio de enriquecimento estéril. Para avaliação da infiltração bacteriana de fora para dentro dos implantes, os conjuntos implantes/componentes foram mergulhados em tubos de ensaio contendo um meio de enriquecimento com cepas da bactéria. Ocorreu infiltração bacteriana em todos os grupos, e não houve diferença estatisticamente significante entre os grupos A e C, nem entre os grupos B e D, em relação à percentagem da passagem do microrganismo na interface implante/componente protético. / The precision in the manufacture of an implant can be determined by the degree of adaptation at the abutment-implant interface. A poor adaptation allows the infiltration of microorganisms through this interface and colonization of empty spaces of the implants, leading to inflammatory reactions and clinical failure of treatment. The aim of the present in-vitro study was to investigate leakage of Staphylococcus aureus through the abutment-implant interface, by the method of bacterial culture. It was used twenty sets of Morse Taper implants with Pillars CM (NEODENTTM, Curitiba, Paraná, Brazil), divided into two groups: Group A, which were evaluated for bacterial infiltration into the inner part of the implants, and Group B, which were evaluated for bacterial infiltration from the inner part of the implants. Were also used twenty sets of Titamax II Plus implants, with the conical Mini Pillars II Plus (NEODENTTM, Curitiba, Paraná, Brazil), divided into two groups: Group C, which were evaluated for bacterial infiltration into the inner part of the implants and Group D, which were evaluated for bacterial infiltration from the inner part of the implants. In the evaluation of bacterial infiltration from the implants, the assemblies had the inner parts inoculated with S. aureus, and each assembly was incubated in BHI broth. For assessment of bacterial leakage into the implants, each assembly was submerged in S. aureus culture in tubes. Bacterial infiltration occurred in all groups, and there was no statistically significant difference between groups A and C, or between groups B and D.
14

Análise comparativa da interface entre intermediários e estruturas fundidas e CAD/CAM em Co-Cr e zircônia antes e após queima de cerâmica e ciclagem mecânica / Comparative analysis of the interface between different abutments and casted or CAD/CAM prostheses before and after ceramic firing and behavior after mechanical cycling.

Coró, Vitor 05 July 2013 (has links)
As próteses sobre implantes apresentam alto índice de sucesso, mas ainda existem relatos de complicações técnicas e mecânicas, principalmente em relação à adaptação e desaperto de parafusos. Técnicas CAD/CAM foram desenvolvidas tentando melhorar adaptação e passividade, e hoje existem vários materiais e sistemas como opção de trabalho. A proposta deste estudo foi avaliar, por meio de leitura em microscópio, a adaptação de próteses de três elementos sobre dois implantes confeccionadas em diferentes materiais, por diferentes técnicas, antes e após a queima de cerâmica. Também foi verificado se o método/material utilizado, assim como o grau de adaptação influenciariam no comportamento das peças frente a um ensaio de fadiga mecânica. Foram formados 5 grupos de 10 amostras (n=10). Após leituras, prensagem de cerâmica e ensaio de fadiga, os dados foram submetidos aos testes ANOVA e Tuckey-Kramers. As médias de desajuste vertical pré e pós aplicação da cerâmica (&mu;m), quando ambos parafusos apertados foram para G1: Estruturas fundidas em Co-Cr com cilindros calcináveis (26,03 ± 18,4) e (36,5 ± 9) G2: Estruturas sobrefundidas em liga de Co-Cr, utilizando cilindros com base de Co-Cr (4,86 ± 5) e (10,5 ± 6); G3: Estruturas fundidas em liga de Co-Cr, associadas à técnica do cilindro cimentado (0 ± 0)e (0 ± 0); G4: Estruturas usinadas em Co-Cr CAD/CAM (0 ± 0) e (2,7 ± 2);G5: Estruturas usinadas em Zircônia CAD/CAM (14,87 ± 9) e (15,2 ± 8). Para a condição de medida com apenas um dos lados apertado, pré e pós cerâmica, do lado parafusado, os resultados foram para G1: 9,63 ± 1 e 34,8 ± 8; G2: 2,37 ± 5 e 11,9 ± 9; G3: 0 ± 0 e 0 ± 0; G4: 0 ± 0 e 3,4 ± 3; G5: 17,69 ± 1 e 20,8 ± 9. Para a condição de medida com apenas um dos lados apertado, pré e pós cerâmica, do lado desparafusado, os resultados foram para G1: 124,22 ± 37 e 129,8 ± 37; G2: 64,79 ± 47 e 80,6 ± 46; G3: 12,34 ± 17 e 2,1 ± 3; G4: 3,54 ± 5 e 17,6 ± 8; G5: 37,77 ± 25 e 42,4 ± 19. O torque de desaperto (Ncm) dos parafusos protéticos foi verificado antes e após ensaio de fadiga com 300.000 ciclos. Os valores médios encontrados foram respectivamente: G1: 5,80 ± 1,23 e 4,11 ± 1,16; G2: 6,30 ± 1,00 e 3,32 ± 0,87; G3: 5,63 ± 1,05 e 3,30 ± 1,46; G4: 7,24 ± 1,05 e 3,44 ± 1,62; G5: 7,75 ± 1,25 e 6,78 ± 1,18. Os grupos CC, Co-Cr CAD/CAM e Zi, apresentaram os melhores resultados quanto ao ajuste vertical, seguidos pelo grupo Co-Cr e calcinável. Os grupos CC, Co-Cr e Co-Cr CAD/CAM apresentaram perda de torque dos parafusos protéticos após oensaio de fadiga mecânica. O grupo Zi teve menor perda de torque entretodos grupos, comparando antes e após o teste de fadiga. Nenhum dos grupos apresentou perda de torque suficiente para que a prótese perdesse estabilidade da junção. / The implant-supported prostheses present a high success rate, but there are still reports of technical and mechanical complications, mainly regarding adaptation and loosening of screws. CAD/CAM techniques have been developed trying to improve adaptation and passivity, and today there are many options of materials and systems to work with. The purpose of this study was to evaluate, by microscope, fitting of three elements prostheses retained by two implants, made of different materials, different techniques, before and after ceramic firing. It was also verified if the method/material used, as well as the degree of adjustment would influence on the behavior of the prostheses after a fatigue test. Five groups of ten specimens were formed (n = 10). After reading, ceramic pressing and fatigue test data were submitted to ANOVA and Tukey-Kramer\'s tests. The mean vertical misfit pre and post application of ceramic (&mu;m), whit both screws tightened to G1: Structures casted in Co-Cr with castable cylinders (26.03 ± 18.4) and (36.5 ± 9) G2: Structures casted in Co-Cr, with Co-Cr basis cylinder (4.86 ± 5) (10.5 ± 6); G3: Structures casted in Co-Cr associated with the cemented cylinder technique (0 ± 0) and (0 ± 0); G4: Machined structures in Co-Cr CAD/CAM (0 ± 0) and (2.7 ± 2), G5: Structures machined in zirconia CAD/CAM (14.87 ± 9) and (15.2 ± 8). To the measurement condition of only one side tighted, pre and post ceramic, on the tightned side, the results were G1: 9.63 ± 1 and 34.8 ± 8; G2: 2.37 ± 5 and 11.9 ± 9; G3: 0 ± 0 and 0 ± 0; G4: 0 ± 0 and 3.4 ± 3; G5: 17.69 ± 1 and 20.8 ± 9. To the measurement condition of only one side tightened, pre and post ceramic, on the untightened side, the results were in G1: 124.22 ± 37 and 129.8 ± 37; G2: 64.79 ± 47 and 80.6 ± 46; G3: 12.34 ± 2.1 and 17 ± 3; G4: 5 ± 3.54 and 17.6 ± 8; G5: 37.77 ± 25 and 42.4 ± 19. The loosening torque of the prosthetic screws (Ncm) was checked before and after fatigue test to 300,000 cycles. The mean values were: G1: 5,80 ± 1,23 e 4,11 ± 1,16; G2: 6,30 ± 1,00 e 3,32 ± 0,87; G3: 5,63 ± 1,05 e 3,30 ± 1,46; G4: 7,24 ± 1,05 e 3,44 ± 1,62; G5: 7,75 ± 1,25 e 6,78 ± 1,18. CC groups, Co-Cr CAD/CAM and Zi, showed the best results regarding vertical adjustment, followed by the Co-Cr group and castable. CC groups, Co-Cr and Co-Cr CAD/CAM presented loss of torque after fatigue test. The Zi group showed less loss of torque among all groups, comparing before and after fatigue test. None of the groups showed enough loosening to loose joint stability.
15

Avaliação in vitro das interfaces dos implantes Cone Morse e Hexágono Interno / In vitro evaluation of the interfaces of the Morse Taper implants and Internal hexagon implants.

Brosco, Roberta Pires Dias 29 January 2014 (has links)
Objetivo: Considerando que a precisão na adaptação do implante ao intermediário transmucoso é fator importante para a longevidade da prótese e que os sistemas de implantes possuem origens diversas na sua fabricação, nos propusemos a verificar a infiltração da bactéria Enterococcus faecalis na interface entre intermediário transmucoso e implantes do tipo Cone Morse e Hexágono Interno no sistema Neodent . Material e Método: A amostra foi composta por 20 implantes do tipo Cone Morse com Index Protético, 20 implantes Titamax Cone Morse e 20 implantes de Hexágono Interno e 20 intermediários transmucosos do tipo Munhão Universal CM Exact, 20 Munhão Universal em corpo único de 3,3 x 5,5 mm e 20 Munhão Universal II Plus com Parafuso. Com o auxílio da Micropipeta o Inóculo foi aspirado, imediatamente após, inserido no interior do implante que se encontrava estático na placa do Dispositivo desenvolvido para este experimento. Os intermediários foram então conectados e apertados com chave digital própria, em seguida, foi dado o torque ao parafuso do intermediário de acordo com as recomendações do fabricante. Após o torque o conjunto, implante-intermediário foi removido da placa do Dispositivo com pinça de titânio e inserido dentro do tubo de ensaio que continha o meio de cultura estéril. Diante do conhecimento da área interna de cada implante, o volume do Inóculo a ser utilizado foi determinado em 1L. Todos os tubos contendo os conjuntos foram numerados e incubados a 37oC por um período de 14 dias. Foi realizado acompanhamento diário para verificação da possível passagem de bactérias do interior do implante para o caldo. O indicativo da passagem de bactéria para o meio foi a turvação do meio de cultura (caldo BHI). Decorrido os 14 dias de observação, os dados foram tabulados e submetidos à Análise de Variância (ANOVA) com nível de significância de 5%, quando detectada diferença estatística, os valores foram submetidos ao Teste de Tuckey para comparações múltiplas. Resultados: O Teste de Tukey evidenciou que houve diferença estatisticamente significante entre o grupo de implantes Cone Morse, Cone Morse Índex e Hexágono Interno, onde o grupo de implantes Cone Morse diferiu estatisticamente do grupo Cone Morse Índex e também do grupo de implantes de Hexágono Interno. O grupo de implantes Cone Morse Índex não diferiu estatisticamente do grupo de implantes de Hexágono Interno, porém o grupo Cone Morse Índex presentou os melhores resultados. / Objective: Whereas the accuracy adaptation of the implant abutment is an important factor for the longevity of the prosthesis, and implant systems have diverse backgrounds in its manufacture, we set out to verify the infiltration of Enterococcus faecalis bacteria at the interface between the abutment and transmucosal implants of Morse Taper and Internal Hex of Neodent system. Material and Methods: The sample consisted of 20 Morse Taper implants, 20 Titamax Morse Taper implants, 20 Internal Hexagon implants and 20 transmucosal Exact CM Universal Post abutment, 20 Universal Post 3 in one body , 3 x 5.5mm and 20 Universal Post II Plus with Screw . With the aid of a micropipette the inoculum was aspirated, immediately thereafter, inserted into the implant that was in the static device board developed for this experiment. The abutments were then connected and tightened to own digital key, then the torque was given to the screw of the abutment according to the manufacturer\'s recommendations. After the torque, deploy abutment was removed from the plate clamp device of titanium and inserted into a test tube containing sterile culture. According to the internal area of each implant, the inoculum size was determined to be 1L. All the tubes were numbered and incubated at 37 ° C for a period of 14 days. Daily monitoring to check the possible passage of bacteria into the interior of the implant broth was carried out. The indication of the passage of bacteria was turbidity of the culture (BHI). Upon expiry of the 14 days of observation, the data were tabulated and an analysis of variance (ANOVA) with a significance level of 5 % was done. The values were submitted to Tukey test for multiple comparisons. Results: The Tukey test showed a statistically significant difference between the group of Morse Taper implants, Cone Morse Index and Internal Hex, where the group of implants differed from Morse Taper, Morse Taper Index group and also the group of Internal Hexagon implants. The group of Morse Taper implants Index did not differ statistically from the group of Internal hexagon implants, but Morse Taper Index group showed the best results
16

Análise comparativa da interface entre intermediários e estruturas fundidas e CAD/CAM em Co-Cr e zircônia antes e após queima de cerâmica e ciclagem mecânica / Comparative analysis of the interface between different abutments and casted or CAD/CAM prostheses before and after ceramic firing and behavior after mechanical cycling.

Vitor Coró 05 July 2013 (has links)
As próteses sobre implantes apresentam alto índice de sucesso, mas ainda existem relatos de complicações técnicas e mecânicas, principalmente em relação à adaptação e desaperto de parafusos. Técnicas CAD/CAM foram desenvolvidas tentando melhorar adaptação e passividade, e hoje existem vários materiais e sistemas como opção de trabalho. A proposta deste estudo foi avaliar, por meio de leitura em microscópio, a adaptação de próteses de três elementos sobre dois implantes confeccionadas em diferentes materiais, por diferentes técnicas, antes e após a queima de cerâmica. Também foi verificado se o método/material utilizado, assim como o grau de adaptação influenciariam no comportamento das peças frente a um ensaio de fadiga mecânica. Foram formados 5 grupos de 10 amostras (n=10). Após leituras, prensagem de cerâmica e ensaio de fadiga, os dados foram submetidos aos testes ANOVA e Tuckey-Kramers. As médias de desajuste vertical pré e pós aplicação da cerâmica (&mu;m), quando ambos parafusos apertados foram para G1: Estruturas fundidas em Co-Cr com cilindros calcináveis (26,03 ± 18,4) e (36,5 ± 9) G2: Estruturas sobrefundidas em liga de Co-Cr, utilizando cilindros com base de Co-Cr (4,86 ± 5) e (10,5 ± 6); G3: Estruturas fundidas em liga de Co-Cr, associadas à técnica do cilindro cimentado (0 ± 0)e (0 ± 0); G4: Estruturas usinadas em Co-Cr CAD/CAM (0 ± 0) e (2,7 ± 2);G5: Estruturas usinadas em Zircônia CAD/CAM (14,87 ± 9) e (15,2 ± 8). Para a condição de medida com apenas um dos lados apertado, pré e pós cerâmica, do lado parafusado, os resultados foram para G1: 9,63 ± 1 e 34,8 ± 8; G2: 2,37 ± 5 e 11,9 ± 9; G3: 0 ± 0 e 0 ± 0; G4: 0 ± 0 e 3,4 ± 3; G5: 17,69 ± 1 e 20,8 ± 9. Para a condição de medida com apenas um dos lados apertado, pré e pós cerâmica, do lado desparafusado, os resultados foram para G1: 124,22 ± 37 e 129,8 ± 37; G2: 64,79 ± 47 e 80,6 ± 46; G3: 12,34 ± 17 e 2,1 ± 3; G4: 3,54 ± 5 e 17,6 ± 8; G5: 37,77 ± 25 e 42,4 ± 19. O torque de desaperto (Ncm) dos parafusos protéticos foi verificado antes e após ensaio de fadiga com 300.000 ciclos. Os valores médios encontrados foram respectivamente: G1: 5,80 ± 1,23 e 4,11 ± 1,16; G2: 6,30 ± 1,00 e 3,32 ± 0,87; G3: 5,63 ± 1,05 e 3,30 ± 1,46; G4: 7,24 ± 1,05 e 3,44 ± 1,62; G5: 7,75 ± 1,25 e 6,78 ± 1,18. Os grupos CC, Co-Cr CAD/CAM e Zi, apresentaram os melhores resultados quanto ao ajuste vertical, seguidos pelo grupo Co-Cr e calcinável. Os grupos CC, Co-Cr e Co-Cr CAD/CAM apresentaram perda de torque dos parafusos protéticos após oensaio de fadiga mecânica. O grupo Zi teve menor perda de torque entretodos grupos, comparando antes e após o teste de fadiga. Nenhum dos grupos apresentou perda de torque suficiente para que a prótese perdesse estabilidade da junção. / The implant-supported prostheses present a high success rate, but there are still reports of technical and mechanical complications, mainly regarding adaptation and loosening of screws. CAD/CAM techniques have been developed trying to improve adaptation and passivity, and today there are many options of materials and systems to work with. The purpose of this study was to evaluate, by microscope, fitting of three elements prostheses retained by two implants, made of different materials, different techniques, before and after ceramic firing. It was also verified if the method/material used, as well as the degree of adjustment would influence on the behavior of the prostheses after a fatigue test. Five groups of ten specimens were formed (n = 10). After reading, ceramic pressing and fatigue test data were submitted to ANOVA and Tukey-Kramer\'s tests. The mean vertical misfit pre and post application of ceramic (&mu;m), whit both screws tightened to G1: Structures casted in Co-Cr with castable cylinders (26.03 ± 18.4) and (36.5 ± 9) G2: Structures casted in Co-Cr, with Co-Cr basis cylinder (4.86 ± 5) (10.5 ± 6); G3: Structures casted in Co-Cr associated with the cemented cylinder technique (0 ± 0) and (0 ± 0); G4: Machined structures in Co-Cr CAD/CAM (0 ± 0) and (2.7 ± 2), G5: Structures machined in zirconia CAD/CAM (14.87 ± 9) and (15.2 ± 8). To the measurement condition of only one side tighted, pre and post ceramic, on the tightned side, the results were G1: 9.63 ± 1 and 34.8 ± 8; G2: 2.37 ± 5 and 11.9 ± 9; G3: 0 ± 0 and 0 ± 0; G4: 0 ± 0 and 3.4 ± 3; G5: 17.69 ± 1 and 20.8 ± 9. To the measurement condition of only one side tightened, pre and post ceramic, on the untightened side, the results were in G1: 124.22 ± 37 and 129.8 ± 37; G2: 64.79 ± 47 and 80.6 ± 46; G3: 12.34 ± 2.1 and 17 ± 3; G4: 5 ± 3.54 and 17.6 ± 8; G5: 37.77 ± 25 and 42.4 ± 19. The loosening torque of the prosthetic screws (Ncm) was checked before and after fatigue test to 300,000 cycles. The mean values were: G1: 5,80 ± 1,23 e 4,11 ± 1,16; G2: 6,30 ± 1,00 e 3,32 ± 0,87; G3: 5,63 ± 1,05 e 3,30 ± 1,46; G4: 7,24 ± 1,05 e 3,44 ± 1,62; G5: 7,75 ± 1,25 e 6,78 ± 1,18. CC groups, Co-Cr CAD/CAM and Zi, showed the best results regarding vertical adjustment, followed by the Co-Cr group and castable. CC groups, Co-Cr and Co-Cr CAD/CAM presented loss of torque after fatigue test. The Zi group showed less loss of torque among all groups, comparing before and after fatigue test. None of the groups showed enough loosening to loose joint stability.
17

Estudo de dois sistemas de reabilitação com implantes submetidos à ativação imediata: análise clínica, radiográfica e da estabilidade, por frequência de ressonância / Study of two rehabilitation systems with dental implants submitted to immediate loading: clinical and radiographic evaluations, and stability using resonance frequency analysis

Eduardo Antonio Ayub 28 August 2007 (has links)
Avaliou-se o comportamento biomecânico, quanto à área de estabilidade protética, extensão de cantilever e estabilidade por análise freqüência de ressonância (AFR); parâmetros clínicos: índice de placa (IP), índice de sangramento (IS), supuração, distância da plataforma do implante-margem da mucosa (DPM), profundidade de sondagem (PS), nível de inserção (NI), sangramento à sondagem (SS), largura (LM), espessura (EM) da mucosa e análise radiográfica, em dois sistemas de reabilitações implanto-suportadas. Foram instalados 104 implantes, submetidos à ativação imediata, em 26 pacientes, divididos em dois grupos: A (n= 16, All-on-4®-Nobel Biocare) e B (n=10, Neopronto®-Neodent). As próteses foram instaladas em tempo médio de 32h. (T0), e controles realizados em seis (T6), doze (T12) e 24 meses (T24). Como resultado, a taxa de sucesso foi de 100% para o grupo A e 90% para o grupo B para implantes e próteses. Diferenças significantes (p<0,05) foram apresentadas entre o cantilever posterior 10,96mm e 18,81mm e o braço de resistência (BR) 13,87mm e 5,50mm, respectivamente para os grupos A e B. A área de estabilidade, no grupo A foi de 373,5mm2 e no B de 112,8mm2; a média da AFR (em ISQ) do grupo A T0= 68,62; T6=64,40; T12=67,07; T24=66,53 e do grupo B T0= 68,37; T6=66,29; T12=67,09; T24=67,10, com diferenças (p<0,05) entre os tempos (grupo A) e posição dos implantes (grupo B). O IP no grupo A=1,0 e 0,7; grupo B=0,6 e 0,9, o IS (0,7), supuração (ausente) e SS (presença) no grupo A=50% e 37,9%; grupo B=70,1 e 52,1%, no controle de 12 e 24 meses, não mostraram diferenças estatísticas entre os grupos. As médias (em mm) da LM para o grupo A (2,05 e 2,21) e B (2,29 e 2,40) e EM grupo A (1,53 e 1,56) e B (1,31 e 1,43), DPM do grupo A (2,54e 2,52) e B (0,18mm e -0,12mm), PS grupo A (3,52 e 3,52) e B (3,52 e 4,0), NI grupo A (0,98 e 0,99) e B (3,05 e 3,57) e perda óssea grupo A (0,45mm e 0,23mm ) grupo B(0,66mm e 0,22mm), respectivamente para 12 e 24 meses, apresentaram diferenças estatísticas entre os controles. Concluindo-se que 1- O grupo A apresentou área de estabilidade e extensão de cantilever anterior e posterior, com comportamento biomecânico mais favorável do que no grupo B; 2- A estabilidade primária e secundária (AFR) foi diferente entre os tempos (grupo A) e posição dos implantes (grupo B), mas semelhantes entre os grupos; 3- Os parâmetros clínicos de índice de placa, sangramento marginal, supuração, profundidade de sondagem (exceto para os períodos de controle no grupo B), sangramento a sondagem, largura e espessura de mucosa ceratinizada foram semelhantes entre os grupos; 4- A distância da plataforma do implante-margem da mucosa foi maior no grupo A e o nível de inserção foi maior no grupo B; 5- A perda na altura da crista óssea foi semelhante entre os grupos; 6- A perda óssea foi menor nos implantes anteriores do que nos posteriores, nos grupos. / Two implant-supported rehabilitation systems were evaluated considering their biomechanical behavior, the area of prosthetic stability, cantilever extensions, stability using resonance frequency analysis (RFA) and clinical parameters, such as: modified plaque index (PI), modified bleeding index (BI), suppuration, distance between the implant shoulder and the mucosal margin (DIM), probing pocket depth (PD), probing attachment level (PAL), bleeding on probing (BP), thickness (TM) width (WM) of keratinized mucosa and radiographic analysis. One hundred and four implants had been installed in twenty six patients, submitted to immediate loading and divided into two groups: A (n=16, All-on-4®-Nobel Biocare) e B (n=10, Neopronto®-Neodent). The prosthesis had been installed in average time of 32h (T0), and controls made in (T6), 12 (T12) and 24 months (T24). As result, the success rate was 100% for the group A and 90% for the group B for both implants and prosthesis. Significant differences (p<0,05) 10,96mm and 18,81mm had been presented between posterior cantilever and the resistance arm (RA) 13,87mm and 5,50mm, respectively for the groups A and B. The stability area, in the group A was of 373,5mm2 and in B of 112,8mm2; the average of RFA (in ISQ) of the group A T0= 68,62; T6=64,40; T12=67,07; T24=66,53 and of the group B T0= 68,37; T6=66,29; T12=67,09; T24=67,10, with differences (p<0,05) between the periods (Group A) and implant position (Group B). The PI in group A was of 1,0 and 0,7 and 0,6 and 0,9 for group B, o BI (0,7), suppuration (absent), DP (presence) in group A=50% and 37,9%; group B=70,1 and 52,1%, in the control of 12 and 24 months, did not present statistical differences between the groups. The average (in mm) of WM for the group A (2,05 and 2,21) and B (2,29 and 2,40) and TM group A (1,53 and 1,56) and B (1,31 and 1,43), DIM of group A (2,54 and 2,52) and B (0,18mm and -0,12mm), DP group.
18

Avaliação in vitro das interfaces dos implantes Cone Morse e Hexágono Interno / In vitro evaluation of the interfaces of the Morse Taper implants and Internal hexagon implants.

Roberta Pires Dias Brosco 29 January 2014 (has links)
Objetivo: Considerando que a precisão na adaptação do implante ao intermediário transmucoso é fator importante para a longevidade da prótese e que os sistemas de implantes possuem origens diversas na sua fabricação, nos propusemos a verificar a infiltração da bactéria Enterococcus faecalis na interface entre intermediário transmucoso e implantes do tipo Cone Morse e Hexágono Interno no sistema Neodent . Material e Método: A amostra foi composta por 20 implantes do tipo Cone Morse com Index Protético, 20 implantes Titamax Cone Morse e 20 implantes de Hexágono Interno e 20 intermediários transmucosos do tipo Munhão Universal CM Exact, 20 Munhão Universal em corpo único de 3,3 x 5,5 mm e 20 Munhão Universal II Plus com Parafuso. Com o auxílio da Micropipeta o Inóculo foi aspirado, imediatamente após, inserido no interior do implante que se encontrava estático na placa do Dispositivo desenvolvido para este experimento. Os intermediários foram então conectados e apertados com chave digital própria, em seguida, foi dado o torque ao parafuso do intermediário de acordo com as recomendações do fabricante. Após o torque o conjunto, implante-intermediário foi removido da placa do Dispositivo com pinça de titânio e inserido dentro do tubo de ensaio que continha o meio de cultura estéril. Diante do conhecimento da área interna de cada implante, o volume do Inóculo a ser utilizado foi determinado em 1L. Todos os tubos contendo os conjuntos foram numerados e incubados a 37oC por um período de 14 dias. Foi realizado acompanhamento diário para verificação da possível passagem de bactérias do interior do implante para o caldo. O indicativo da passagem de bactéria para o meio foi a turvação do meio de cultura (caldo BHI). Decorrido os 14 dias de observação, os dados foram tabulados e submetidos à Análise de Variância (ANOVA) com nível de significância de 5%, quando detectada diferença estatística, os valores foram submetidos ao Teste de Tuckey para comparações múltiplas. Resultados: O Teste de Tukey evidenciou que houve diferença estatisticamente significante entre o grupo de implantes Cone Morse, Cone Morse Índex e Hexágono Interno, onde o grupo de implantes Cone Morse diferiu estatisticamente do grupo Cone Morse Índex e também do grupo de implantes de Hexágono Interno. O grupo de implantes Cone Morse Índex não diferiu estatisticamente do grupo de implantes de Hexágono Interno, porém o grupo Cone Morse Índex presentou os melhores resultados. / Objective: Whereas the accuracy adaptation of the implant abutment is an important factor for the longevity of the prosthesis, and implant systems have diverse backgrounds in its manufacture, we set out to verify the infiltration of Enterococcus faecalis bacteria at the interface between the abutment and transmucosal implants of Morse Taper and Internal Hex of Neodent system. Material and Methods: The sample consisted of 20 Morse Taper implants, 20 Titamax Morse Taper implants, 20 Internal Hexagon implants and 20 transmucosal Exact CM Universal Post abutment, 20 Universal Post 3 in one body , 3 x 5.5mm and 20 Universal Post II Plus with Screw . With the aid of a micropipette the inoculum was aspirated, immediately thereafter, inserted into the implant that was in the static device board developed for this experiment. The abutments were then connected and tightened to own digital key, then the torque was given to the screw of the abutment according to the manufacturer\'s recommendations. After the torque, deploy abutment was removed from the plate clamp device of titanium and inserted into a test tube containing sterile culture. According to the internal area of each implant, the inoculum size was determined to be 1L. All the tubes were numbered and incubated at 37 ° C for a period of 14 days. Daily monitoring to check the possible passage of bacteria into the interior of the implant broth was carried out. The indication of the passage of bacteria was turbidity of the culture (BHI). Upon expiry of the 14 days of observation, the data were tabulated and an analysis of variance (ANOVA) with a significance level of 5 % was done. The values were submitted to Tukey test for multiple comparisons. Results: The Tukey test showed a statistically significant difference between the group of Morse Taper implants, Cone Morse Index and Internal Hex, where the group of implants differed from Morse Taper, Morse Taper Index group and also the group of Internal Hexagon implants. The group of Morse Taper implants Index did not differ statistically from the group of Internal hexagon implants, but Morse Taper Index group showed the best results
19

Complete-arch implant-supported frameworks produced by different manufacturing techniques and materials: a stress deformation and internal fit analysis / Infraestruturas para próteses totais sobre implantes confeccionadas por diferentes métodos e materiais: análise das deformações geradas na região peri-implantar e da adaptação interna

Marques, Milena Steluti 12 December 2018 (has links)
Statement of problem: With the variety of materials and techniques available, the knowledge of which combination provides frameworks with a better biomechanical behavior and greater fit accuracy is essential for a planning aiming prosthesis longevity. Purpose. To analyze which manufacture technique and material provides a better stress/strain and internal fit correlation. Material and methods. The groups were divided according to framework material and fabrication method: Titanium milled (TiCAD), Zirconia milled (ZrCAD), Cobalt-Chromium alloy milled (CoCrCAD), one-piece casting CoCr alloy (CoCrCAS) and cast and welded CoCr alloy (CoCrWEL). Four external hexagon implants and their respective mini-abutments were placed parallel to each other in a polyurethane model. This model was duplicated, scanned, and a single framework design was created to be used for all milled groups. Casting was done from a wax milled pattern following the same framework design used for the other groups. In preload condition, the strains generated by each framework were recorded by strain gauges fixed around the implants. The internal fit was evaluated by micro-CT scanning. Results. Regarding the uniformity of stress distribution, ZrCAD and CoCrCAD groups presented irregular stress distribution, while TiCAD presented the most uniform distribution. Regarding the internal fit, the TiCAD group presented values significantly better than the others, but not statistically different from ZrCAD. The three manufacturing methods associated to CoCr alloy presented no statistical differences among them. The correlation between the method was statistically significant. Conclusion. The physical and mechanical properties of the complete-arch implant-supported frameworks materials influence the stresses distribution and internal fit. TiCAD presented the best framework stress/strain ratio and internal fit. / Afirmação do problema. Diante da variedade de materiais e técnicas disponíveis, ter o conhecimento de qual combinação proporciona infraestruturas com um melhor comportamento biomecânico e maior precisão na adaptação é essencial para um planejamento visando a longevidade da prótese. Finalidade. Analisar qual material e método de confecção das infraestruturas proporciona a melhor relação tensão/deformação e adaptação interna. Material e métodos. Os grupos foram divididos de acordo com o material e forma de confecção das infraestruturas: fresado em Titânio (TiCAD), fresado em Zircônia (ZrCAD), fresado em Cobalto Cromo (CoCrCAD), CoCr fundido em monobloco (CoCrCAS) e CoCr fundido e com ponto de solda (CoCrWEL). Quatro implantes hexágonos externos e seus respectivos mini-abutments foram colocados paralelos entre si em um modelo de poliuretano. Este modelo foi duplicado, digitalizado e um único desenho de infraestrutura foi criado para todos os grupos fresados. Para fundição, foi utilizado um padrão de cera fresado a partir do projeto usado nos outros grupos. Na condição de pré-carga, as tensões geradas por cada infraestrutura foram registradas por strain gauges fixados ao redor dos implantes. A adaptação interna foi avaliada através de escaneamento por micro-CT. Resultados. Quanto a uniformidade na distribuição das tensões, os grupos ZrCAD e CoCrCAD se apresentaram irregulares, sendo que o grupo TiCAD apresentou distribuição mais uniforme. Quanto à adaptação interna, o grupo TiCAD apresentou valores significativamente melhores que os demais, mas sem diferença estatística em relação ao grupo ZrCAD. As três formas de produção da infraestrutura usando a liga de CoCr não apresentaram diferenças estatísticas entre si. A correlação entre os métodos foi estatisticamente significativa. Conclusão. As propriedades físicas e mecânicas dos materiais de confecção das infraestruturas influenciam na distribuição de estresses e na adaptação interna. O grupo que apresentou a melhor relação tensão/deformação e adaptação foi o grupo TiCAD.

Page generated in 0.2315 seconds