Spelling suggestions: "subject:"implantes dentários"" "subject:"aimplantes dentários""
261 |
Mechanical integrity of glass ceramic restorations on morse taper implant-abutment systemVahey, Brendan Robert January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016. / Made available in DSpace on 2017-05-31T14:10:36Z (GMT). No. of bitstreams: 1
345797.pdf: 1572899 bytes, checksum: 725105f21dad2b7bae080598af256d22 (MD5)
Previous issue date: 2016 / O principal objetivo deste estudo foi avaliar a integridade mecânica após fadiga de coroas de silicato de lítio reforçadas com zircônia cimentadas e conectadas a sistemas de implantes do tipo cone Morse. Quarenta implantes de titânio foram inseridos em bases de poliacetal simulando osso de suporte. Os pilares protéticos correspondentes foram conectados aos implantes usando um torque de 20 N.cm controlado por um torquímetro digital portátil. Estruturas protéticas unitárias foram projetadas por computador para produzir coroas vitrocerâmicas de dissilicato de lítio (LD) ou silicato de lítio e zircônio (LZS) por termo- pressão. Após cimentação e conexão das coroas, os grupos implante-pilar-coroa foram submetidos a testes de fadiga (n = 10) sob uma carga de 200 N em 500.000 ciclos a 5 Hz imersos em solução eletrolítica a 37 °C. Depois dos ensaios de fadiga, as coroas de cada grupo foram removidas para avaliar valores de torque de remoção do pilar protético ao implante (n = 7). Os grupos de coroa-implante-pilar restantes foram seccionadas transversalmente em 90° em relação ao plano da conexão pilar-implante para a inspeção de fraturas e microgaps por microscopia eletrônica de varredura. Grupos controle foram imersos na solução eletrolítica mas não foram submetidos aos testes de fadiga. Após imersão em solução e sem efeito de fadiga, os valores de torque de remoção dos pilares para os grupos LD e LZS estavam em 18,014 ± 1,634 N.cm e 18,214 ± 0,813 N.cm, respectivamente. No entanto, os valores de torque de remoção diminuíram significativamente em ambos os grupos, registrando valores de 12,8 ± 1,6 N.cm e 14,9 ± 1,08 N.cm, para o grupo LD e o grupo LZS, respectivamente (p <0,05). Não houve diferença significativa nos valores de torque de remoção entre os dois grupos não submetidos à fadiga assim como entre os dois grupos teste (após fadiga). A análise microscópica revelou que o tamanho dos microgaps (0,9 ± 0,3 µm) encontrado em conexões implante-pilar aumentou significativamente (4,2 ± 0,9 µm) para os grupos submetidos a testes de fadiga (p<0,05). Além disso, foram detectadas micro-trincas nas interfaces entre coroa-adesivo e adesivo-pilar em ambos os sistemas após testes de fadiga. As coroas vitrocerâmicas à base de silicato de zircônio e lítio cimentadas e aparafusadas aos implantes dentários resistiram aos testes de fadiga simulando um período de seis meses de mastigação. No entanto, os resultados confirmaram uma diminuição do torque nos pilares com o aumento dos microgaps das conexões pilar-implante e a presença de micro-trincas nas interfaces coroa-adesivo como consequência do estímulo mecânico dinâmico.<br> / Abstract : The main aim of this study was to assess the mechanical integrity of zirconium- lithium silicate crowns cement- and screw- retained to a Morse taper titanium implant-abutment system after fatigue. Forty titanium implants were placed in poliacetal to mimic bone support. Abutments were torqued to the implants on 20 N.cm using a digital handheld torque meter. Each implant-abutment received a unit maxillary premolar crown that was computer-designed and hot-pressed. Crowns were divided into two groups: A) lithium disilicate (LD); or B) zirconium-lithium silicate glass-ceramic (LZS). Implant-abutment-crown groups were submitted to mechanical cycling tests (n = 10) on 200 N at 5 Hz for 500,000 cycles in a Ringer?s electrolytic solution (37 °C). After fatigue tests, crowns from each group were removed to evaluate removal torque values on abutment to implant. The remaining crown-implant-abutment assemblies were cross-sectioned at 90° to the implant-abutment joint for inspection of cracks and the microgap by scanning electron microscopy. After immersion in Ringer's solutions, removal torque values without effect of fatigue recorded for LD group were at 18.0 ± 1.6 N.cm while values at 18.2 ± 0.8 N.cm were recorded for LZS group. However, removal torque values after fatigue tests significantly decreased down to 12.8 ± 1.6 N.cm for LD while LZS group revealed values at 14.9 ± 1.1 N.cm for LZS (p < 0.05). There was no significant difference in torque values between the test groups after fatigue. Microscopic analyses revealed that the microgap size found at implant-abutment connections at about 0.9 ± 0.3 µm significantly increased up to 4.2 ± 0.9 µm for the groups subjected to fatigue tests. Also, cracks at the crown-adhesive or at adhesive-abutment interfaces were detected at both systems after fatigue tests. Zirconium-lithium silicate glass-ceramic crowns cement- and screw-retained to dental implants were mechanically successful under fatigue testing in an electrolyte solution. However, the findings confirmed a loosening of mechanical integrity of the crown-adhesive-abutment interfaces as well as decrease in removal torque values on abutment to implant joints after fatigue.
|
262 |
Resistência à fadiga de diferentes restaurações de resina composta e cerâmica CAD/CAM, simulando o complexo dentina / esmalteContreras Molina, Ivan January 2015 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2015. / Made available in DSpace on 2016-04-15T13:13:44Z (GMT). No. of bitstreams: 1
337937.pdf: 1293144 bytes, checksum: e37ab121497052a0c3e8bd01d4af585c (MD5)
Previous issue date: 2015 / Este estudo avaliou a resistência à fadiga de um projeto histo-anatômico experimental, com uma restauração bilaminada sobre implante confeccionada em cerâmica e resina nano-híbrida, além do efeito da seleção desses materiais. O sistema Cerec 4 CAD/CAM (versão 4.3, Sirona Dental Systems GmbH, Bensheim, Alemanha) foi utilizado para o desenho digital de 60 restaurações sobre implantes, realizando dois diferentes desenhos (desenho 1: coroa monolítica; desenho 2: desenho experimental simulando o complexo dentina-esmalte), totabilizando 4 grupos experimentais (n=15). Trinta coroas monolíticas foram fabricadas, sendo 15 em dissilicato de lítio (Grupo CE - Emax; Ivoclar Vivadent, Liechtenstein) e 15 em resina nanohíbrida (Grupo CL - Lava Ultimate; 3M/ESPE, EUA). Além disso, 15 mesoestruturas foram fabricadas em dissilicato de lítio simulando a dentina (Emax; Ivoclar Vivadent, Liechtenstein) associadas à 15 facetas em resina nanohíbrida simulando o esmalte (Grupo CEL - Lava Ultimate; 3M/ESPE, EUA) e 15 mesoestruturas em resina nano-híbrida (Lava Ultimate; 3M/ESPE, EUA) associadas com 15 facetas em dissilicato de lítio (Grupo CLE (Emax; Ivoclar Vivadent, Liechtenstein). As restaurações foram cimentadas sobre pilares de titânio personalizados (Solid Metal Abutment CM Universal Post, diâmetro 3,3mm, altura 4,0mm e cinta 0,8mm; Neodent, Curitiba, Brasil) aparafusados aos implantes (Cone Morse, Titamax CMEx 3,5mm x 10mm; Neodent, Curitiba, Brasil). Para as cerâmicas, as superfícies internas das restaurações foram condicionadas com ácido hidrofluorídrico e silanizadas (Ultradent, EUA), e no caso das resinas nanohídridas, jateadas e silanizadas. O protocolo adesivo após o aparafusamento do pilar sobre o implante utilizou adesivo (Optibond FL Bottle 2; Kerr, EUA) e resina composta fotopolimerizável pré-aquecida (Filtek Z100; 3M-ESPE, EUA). Os espécimens foram submetidos ao teste de esforço, simulando um movimento mastigatório cíclico e isométrico (5Hz) com carga de 50N (5.000 ciclos), seguido dos ciclos de 150N, 200N, 250N, 300N, 350N, 400N e 450N até um máximo de 20.000 ciclos em cada fase. Cada espécime foi carregado até fraturar ou até um máximo de 160.000 ciclos.Para o grupo CL, as restaurações fraturaram sob carga média de 347,39N (após 98.361 ciclos) e para o grupo CLE, a carga média foi de 313.20N (após 83.105 ciclos), Neste grupo, nenhum dos espécimens resistiu a todos os ciclos de carga (160.000). Para os grupos CE, as fraturas ocorreram com carga média de 381.47N (após 119.115 ciclos) e para o grupo CEL, sob 415.20N (após 132.873 ciclos). Suas respectivas taxas de sobrevivência foram de 26% e 33%. Testes Post-hoc com os dados das etapas de carregamento demonstraram uma maior resistência à fadiga para o grupo CEL quando comparado com o grupo CLE (p = 0,003). Falhas na restauração não ocorreram; porém, falhas de adesão na conexão entre a base de titânio e a mesoestrutura foram observadas. Coroas monolíticas e mesoestruturas de dissilicato de lítio facetadas com resina nanohíbrida apresentaram taxas de sobrevida mais altas quando comparadas com restaurações de resina nanohíbridas totais e mesoestruturas.<br> / Abstract : Evaluate the fatigue resistance and failure mode of novel-design implant restorations made of histo-anatomic bilaminar assemblies. 60 implant restorations were fabricated. Monolithic crowns were used as a control group (15 lithium disilicate; group CE, and 15 nano-filled composite resin; group CL) and compared to bi-laminar restorations: 15 dentin- shaped lithium disilicate mesostructures with a nanofilled composite resin veneer (group CEL) and 15 dentin-shaped nanofilled composite resin mesostructures with a lithium disilicate veneer (group CLE). All monolithic and bi-laminar restorations were assembled and bonded to a customized metal implant abutment. Cyclic isometric chewing (5Hz) was simulated, starting with 5,000 cycles at a load of 150N, followed by 20,000 cycles with increments of 50N. Samples were loaded until fracture or to a maximum of 160,000 cycles. The groups were compared using the life table survival analysis (Logrank test at p=.05, post-hoc tests at p=.008). Results: In group CL, restorations failed at an average load of 347.39N (98.361 cycles) and for CLE at an average load of 313.20N (83.105 cycles) and none of the specimens withstood all 160,000-load cycles. For groups CE, failures were at an average load of 381.47N (119.115 cycles) and for CEL at 415.20N (132.873 cycles), with survival rates of 26% and 33% respectively. Post hoc tests from load step data showed higher fatigue resistance of CEL compared to CLE (p=.003). Lithium disilicate monolithic crowns and mesostructures with nanofilled composite resin veneer presented higher survival rates when compared to nanofilled composite resin restorations.
|
263 |
Efeito do design de pilares personalizados implantossuportados na resistência à fadiga de coroas CAD/CAM de polimeros de alta performanceOliveira, Rafaella Monteiro Cid January 2016 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T04:45:26Z (GMT). No. of bitstreams: 1
341965.pdf: 2346755 bytes, checksum: 6feb351b67a1a36944e34a78ed9321f7 (MD5)
Previous issue date: 2016 / Coroas CAD/CAM de polímeros de alta performace (HPPC) representam uma nova opção para reabilitações implantossuportadas. Pouco se sabe sobre a influência do design do pilar sobre o desempenho destas restaurações. Objetivos: O presente estudo teve como objetivo avaliar in vitro, a resistência à fadiga e o modo de falha de HPPC cimentadas adesivamente sobre três diferentes designs de pilares implantossuportados de titânio. Materiais e Métodos: Cinqüenta e uma (51) coroas HPPC (Lava Ultimate) foram fabricadas utilizando o sistema CAD/CAM CEREC SW 4.0. Após a instalação dos pilares em implantes cone morse (CM Titamax EX), estes foram restaurados adesivamente com HPPC (jateada com Al2O3 e silanizada) usando adesivo (Optibond FL) e resina composta polimerizada pré-aquecida (Filtek Z100). Os pilares foram divididos em três grupos experimentais (n=17): Grupo REG (controle) Ø4. 0x4.0mm - CM Universal Post (pilar original do fabricante); Grupo SLIM Ø2.0x4.0mm - CM Universal Post Modificado (redução do diâmetro); Grupo SLIM/SHORT Ø2.0x2.0mm - CM Universal Post Modificado (redução do diâmetro e de altura). Movimentos cíclicos isométricos mastigatórios (5Hz) foram simulados por meio de carga axial, iniciando com uma carga de 200N, seguindo por cargas de 400N, 600N, 800N, 1000N, 1200N e 1400N (com máximo de 25.000x cada). As amostras foram carregadas até fratura ou a um máximo de 175 mil ciclos. Os três grupos foram comparados através da análise de sobrevivência Kaplan Meier e teste Logrank (valor de significância de p = 0,05). Resultados: A média da carga/ciclos até a falha para os grupos REG, SLIM e SLIM/SHORT foram respectivamente 1,329N/155,924x; 1,071N/119,598x e 1,400N/ 171,409x. As taxas de sobrevivência variam de47% para REG, 17% para o SLIM, e 82% para SLIM/SHORT com uma diferença significativa na probabilidade de sobrevivência (p <0,0001). A maioria das falhas foram mistas (adesiva e coesiva) e algumas falhas exclusivas adesivas. Não houve nenhuma falha do pilar ou afrouxamento do parafuso.Conclusão: O grupo SLIM/SHORT apresentou melhores resultados durante os testes, sugerindo que a espessura das coroas de polímeros de alta performace promove um efeito de amortecimento através de uma absorção de forças. Além de facilitar o desenvolvimento morfológico e estético da restauração.<br> / Abstract : CAD/CAM high performance polymers crown (HPPC) represent a new option for implant-supported crowns. Little is known about the influence of the abutment design on the performance of those restorations.Objectives: The aim of the present study was to assess in vitro the fatigue resistance and failure mode of CAD/CAM HPPC bonded to titanium implant abutments with three different designs.Materials and methods: Fifty-one (51) HPPC (Lava Ultimate) were fabricated using CAD/CAM CEREC SW 4.0. Following insertion into a Morse taper implants (CM Titamax EX), the abutments (air-abraded, silanated) were adhesively restored with CAD/CAM HPPC (air-abraded, silanated) using adhesive resin (Optibond FL) and preheated light curing composite resin (Filtek Z100). There were 3 experimental groups (n = 17): Group REG (control) Ø4.0x4.0mm ? CM Universal Post (original manufacturer?s abutment); Group SLIM Ø2.0x4.0mm- Modified CM Universal Post (reduced width); Group SLIM/SHORT Ø2.0x2.0mm - Modified CM Universal Post (reduced height and width). Cyclic isometric chewing movements (5Hz) were simulated by axial loading, starting with 200N, followed by stages of 400N, 600N, 800N, 1,000N, 1,200N and 1,400N, at a maximum of 25,000x each. Samples were loaded until fracture or to a maximum of 175,000x. The three groups were compared using Kaplan Meier and Logrank test (p = 0.05).Results: The average load/cycles until failure for REG, SLIM and SLIM/SHORT respectively were 1,329N/155,924X; 1,071N/119,598X and 1,400N/171,409X. Survival rates ranged from 47% for REG, 17% for SLIM, and 82% for SLIM/SHORT with a significant difference in survival probability (p<0.0001). Most failures were mixed cohesive and adhesive and some of them were complete adhesive failure without abutment failure nor screw loosening.Conclusion: The SLIM/SHORT abutments presented the highest survival rates, Suggesting that the thickness of high performance polymers crowns promotes a more tooth-like damping behavior, resulting in a strong force 23absorption despite the rigidity of the fixture. The increased thickness of the crown with SLIM/SHORT abutments will also facilitate the development of esthetic and morphology of the restoration.
|
264 |
Qualidade de vida e fatores clínicos associados a percepção da dificuldade de higienização em pacientes com reabilitações implantossuportadasCorrêa, Bruna Barbosa January 2016 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2016. / Made available in DSpace on 2016-09-20T04:59:31Z (GMT). No. of bitstreams: 1
339548.pdf: 1778406 bytes, checksum: 14d38cce515eae77c2aaa49537a1daad (MD5)
Previous issue date: 2016 / O objetivo deste estudo foi identificar as associações das variáveis sócio demográficas, de satisfação e clínicas com o grau de dificuldade de higienização em pacientes com reabilitações implantossuportadas. Foram examinados 183 pacientes, reabilitados com 910 implantes, entre 1998 e 2012. Todos os implantes encontravam-se em função há pelo menos 1 ano, na fase protética definitiva. Foram coletados e registrados nos prontuários, dados relacionados à idade, sexo, localização (anterior; posterior), gengiva artificial (ausente; presente), tipo de prótese (unitária; parcial; total; overdenture), tempo de prótese (=5; >5 anos) e diagnóstico (saudável; doença peri-implantar). Além disso, os pacientes responderam a um questionário ? Dental Impact on Daily Living (DIDL) que avalia a satisfação com o tratamento. O DIDL possui 36 questões distribuídas em cinco dimensões: aparência, dor, conforto, desempenho e mastigação. O instrumento gera uma pontuação total final, além de pontuações para cada dimensão. O teste qui-quadrado de Pearson foi utilizado para avaliar as associações entre sexo, idade, variáveis clínicas e de satisfação com a dificuldade de higiene. Idade e sexo mostraram associação com a dificuldade de higiene (p<0,001 e p=0,001, respectivamente). Em relação à satisfação, apenas conforto e satisfação total apresentaram resultados estatisticamente significativos (p=0,005 e p=0,006, respectivamente). Para as variáveis clínicas, presença de gengiva artificial, tipo e tempo de prótese mostraram associação positiva com a dificuldade de higiene (p=0,001, p<0,001 e p=0,006, respectivamente). Pacientes com mais de 50 anos, sexo feminino, presença de gengiva artificial, próteses totais fixas e tempo de prótese =5 anos foram associados à dificuldade de higienização das reabilitações implantossuportadas. Associações positivas também foram encontradas em relação ao conforto e satisfação total.<br> / Abstract : The aim of this study was to identify associations of sociodemographic, satisfaction and clinics variables with the difficulty of hygiene in patients with implant rehabilitations. One hundred eighty-three patients rehabilitated with 910 implants in function for at least 1 yearwere examined.Data related to age, sex, location (anterior; posterior), artificial gingiva (absent; present), type of prosthesis (single; fixed parcial; fixed or removable full-arch restoration), time in function (=5; >5 years) and diagnosis (health; peri-implant disease) were collected and documented in the medical records. In addition, patients answered a questionnaire ? Dental Impact on Daily Living (DIDL), which assesses satisfaction with treatment. The DIDLconsists of 36 items that aregrouped intofive dimensions: appearance, pain, comfort, general performanceand eating restriction.The instrument generates a total final score, in addition to scores for each dimension.The Pearson?s chi-square test was used to assess associations between age, sex, clinical variables and satisfaction with the oral hygiene difficulty. Age and sex showed association with the oral hygiene difficulty of (p<0.001 and p=0.001, respectively). Regarding satisfaction, only comfort and total satisfaction presented statistically significant results (p=0.005 and p=0.006, respectively). For the clinical variables, artificial gingiva, type of prosthesis and time in function showed positive association with the difficulty of hygiene (p=0.001, p<0.001 and p=0.006, respectively). Patients older than 50 years of age, female, presence of artificial gingiva, complete fixed prosthesis and time in function =5 years were associated with hygiene difficultyon implant rehabilitation. Positive associations were also found in relation to comfort and total satisfaction.
|
265 |
Análise comparativa entre o enxerto alógeno e o autógeno para a reconstrução das fendas alveolares dos pacientes fissuradosZétola, André Luis January 2002 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde . Programa de Pós-Graduação em Odontologia. / Made available in DSpace on 2012-10-20T03:02:35Z (GMT). No. of bitstreams: 1
208303.pdf: 1617432 bytes, checksum: a23f0efbcd019d5d9ffde9daf8c2b3b6 (MD5) / O objetivo deste estudo foi avaliar radiograficamente a quantidade de ganho ósseo do material substitutivo para enxerto do Banco de Ossos, com origem alógena, adicionado aos Fatores de Crescimento derivados do Plasma Rico em Plaquetas (PRP) aplicados para a reconstrução da fissura alveolar palatina. Utilizando como padrão comparativo o enxerto ósseo autógeno de origem intrabucal. Foram selecionados 30 pacientes portadores de fissuras unilaterais. Divididos em dois grupos, um denominado "controle" (osso autógeno de origem intrabucal) e o segundo, denominado "teste", (osso alógeno congelado associado ao PRP). Após quatro meses da cirurgia, o ganho ósseo foi avaliado através de radiografias digitais com o Sistema SENS-A-RAY 2000. Os resultados da avaliação do ganho ósseo total em cada paciente no grupo-controle (t de student) variaram entre 34,12% até 100%, o ganho ósseo médio desse grupo foi de 79,9%. Enquanto que, no grupo-teste o pior desempenho foi de 14,16% e o maior foi de 100% da área total de aumento ósseo; já a média geral de ganho ósseo do grupo foi de 79,88% (t de student). Com relação à análise de variança multifatorial (multifactor ANOVA), com nível de 95% de confiança, demonstrou-se que na mensuração digital em função dos fatores: grupo, idade e sexo; não houve diferença estatisticamente significante. Concluiu-se que, ambos os materiais de enxerto demonstraram um excelente desempenho na reconstrução da fenda alveolar dos pacientes portadores de fissura alvéolo-palatina e, que, o ganho ósseo não teve diferença estatística entre os dois grupos avaliados.
|
266 |
Análise dimensional de modelos de trabalho para a construção de próteses implanto-suportadas, obtidas através de diferentes materiais de vazamentoVolpato, Cláudia Ângela Maziero January 2001 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia / Made available in DSpace on 2012-10-19T06:24:45Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T23:40:03Z : No. of bitstreams: 1
179379.pdf: 1611665 bytes, checksum: 2d7b1489504bd3f3e5560bf73d013e16 (MD5) / Com o propósito de avaliar o comportamento dimensional de modelos de trabalho, utilizou-se 40 corpos de prova obtidos com gesso tipo IV, gesso tipo V, gesso reforçado por resina e resina poliuretânica. Três implantes foram posicionados paralelamente e de forma triangular na base metálica de um modelo-mestre, e as moldagens foram executadas com o auxílio de moldeiras e silicona. As distâncias AB, BC e AC (obtidas entre o centro dos implantes) foram medidas por uma máquina de medição por coordenadas. Os modelos obtidos com a resina poliuretânica apresentaram-se contraídos em AB e AC (-0,72% e -0,49%). Expansão foi encontrada nos modelos de gesso tipo V (AB: 0,002% e AC 0,29%). Os modelos de gesso tipo IV e reforçado por resina apresentaram comportamento dimensional estatisticamente similar ao modelo-mestre. Os dados da distância BC não se mostraram estatisticamente significantes.
|
267 |
Estudo comparativo do Biogran® e Endobon® associados a implantes com defeitos periimplantaresCarvalho, Helen Ramon Esper de [UNESP] 04 September 2015 (has links) (PDF)
Made available in DSpace on 2016-02-05T18:30:11Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-09-04. Added 1 bitstream(s) on 2016-02-05T18:34:21Z : No. of bitstreams: 1
000857959.pdf: 2588157 bytes, checksum: e2c7920ee93dc1516ef1b9eceaece7bd (MD5) / Introdução: A utilização de biomateriais em reconstruções para implantodontia tem sido amplamente discutida nos últimos anos. Proposição: O objetivo deste trabalho foi analisar o comportamento biológico do vidro bioativo (Biogran®) e do osso bovino (Endobon®) durante o processo de osseointegração associados a implantes com defeitos periimplantares em tíbias de rato. Material e método: Foram instalados 75 implantes na tíbia esquerda de 75 ratos Wistar machos. Os implantes foram divididos em três grupos experimentais. No Grupo 1 (Controle) foi provocado um defeito periimplantar monocortical circular e os implantes foram inseridos e deixados apenas com coágulo. No Grupo 2 os implantes foram inseridos com o mesmo defeito ósseo e o espaço preenchido com Biogran® e no Grupo 3 o espaço entre osso e implante foi preenchido com Endobon®. Os animais foram submetidos à eutanásia aos 14 e 42 dias e realizaram-se as análises histológica, histométrica (porcentagem de extensão linear de contato osso-implante - BIC e área óssea - BA), imunoistoquímica (expressão das proteínas osteocalcina - OC e osteopontina - OPN) e biomecânica (torque reverso). Resultados: Histologicamente todos os implantes encontraram-se osseointegrados. Não foram observadas diferenças estatisticamente significantes nos valores de torque reverso (p> 0,05) aos 42 dias. Para BIC, aos 14 dias foi de 8,29; 15,04; e 16,20%, para os grupos 1, 2 e 3, respectivamente. Aos 42 dias, os valores médios de BIC foram 30,84; 33,13; e 13,93% para os mesmos grupos, demonstrando que não houveram diferenças estatísticas entre grupos, porém com respostas diferentes entre períodos. Para a quantificação de formação óssea por área (BA), a resposta entre grupos difere. A resposta da BA média do Grupo 1 (18,75%) não difere da resposta média do Grupo 3 (21,62%). Porém, difere... / Introduction: The use of biomaterials in reconstructions for dental implants has been widely discussed in recent years. Proposition: The aim of this work was to analize the biological behavior of the bioactive glass (Biogran®) and bovine bone (Endobon®) during the osseointegration process associated with implants with peri-implant defects in rat tibia. Material and Methods: 75 implants were installed in the left tibia of 75 male Wistar rats. The implants were divided into three experimental groups. In Group 1 (Control) was caused monocortical circular peri-implant defect and the implants were inserted and left only with clot. In Group 2 implants were inserted with the same bone defect and the space filled with Biogran® and in Group 3 the space between bone and implant was filled with Endobon®. The animals were euthanized at 14 and 42 days and there were the histological analysis, histometric (percentage of linear extension bone-implant contact - BIC and bone area - BA), immunohistochemistry (expression of the proteins osteocalcin - OC and osteopontin - OPN) and biomechanics (reverse torque). Results: Histologically all implants were osseointegrated. No statistically significant differences were observed in the values of reverse torque (p> 0.05) at 42 days. For BIC, at 14 days was 8.29; 15.04; and 16.20% for the groups 1, 2 and 3, respectively. After 42 days, the BIC values were 30.84; 33.13; and 13.93% for the same groups, demonstrating that there were no statistical differences between groups, but with different responses between periods. For the quantification of bone formation per area (BA), the response differs between groups. The average BA response in Group 1 (18.75%) did not differ from the average Group 3 response (21.62%). However, different from Group 2 (34.73%). The immunohistochemical results were analyzed by Qualitative...
|
268 |
Avaliação do uso de uma estrutura de nylon modificada como reforço de prótese totalmente acrílica implantossuportadaGonçalves, Fernanda de Cássia Papaiz [UNESP] 03 December 2015 (has links) (PDF)
Made available in DSpace on 2016-04-01T17:55:15Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-12-03. Added 1 bitstream(s) on 2016-04-01T18:01:15Z : No. of bitstreams: 1
000860671.pdf: 2218695 bytes, checksum: eb80ba359b0f6e3cf6bd8c9c2dcef065 (MD5) / O estudo avalou o comportamento de uma estrutura de nylon experimental com o propósito de ganho na resistência mecânica do material e ainda, na melhor distribuição de forças em toda extensão da prótese ao longo eixo dos implantes diminuindo o risco de fraturas e falhas neste sistema e, consequentemente maior longevidade. Para isso considerou-se próteses do tipo protocolo sem barra metálica, com e sem incorporação de reforço (nylon), variando a extensão da região do cantilever até primeiro molar/ segundo pré-molar (n=6). Os corpos de prova foram submetidos à análise de deformação por extensometria (extensometria s) e carga de 30 kg, e ao teste de carga máxima à fratura na EMIC (1000 kgf, 2 mm/min). Pode-se concluir que a incorporação da estrutura de reforço aumentou os valores de carga máxima independentemente da extensão do cantilever, além de apresentar menores valores de micro deformação ao redor de todos os implantes. As extensões de cantilever em pré-molar (5mm) além de apresentarem os menores valores de micro deformação quando comparadas a extensão em molar (15mm) também mostraram os maiores valores de carga máxima à fratura. / The study evaluated the behavior of a new compound of experimental nylon fiber, with the purpose of increasing the mechanical strength of the material and improving the strain distribution to the fullest extent of the prosthesis to the long axis of the implants reducing the risk of fractures and faults in the system and therefore increasing longevity. For this considered protocol type prostheses without metal bar, with and without incorporating reinforcement (nylon), varying the extent of the region of the cantilever to the first molar / second premolar (n = 6). The samples were subjected to analysis by extensometer strain (extensometria ) and load of 30 kg, and the maximum load test to fracture the EMIC (1000 kgf, 2 mm / min). It can be concluded that the incorporation of reinforcing mesh increased maximum load values regardless of the extent of the cantilever, and exhibit lower values microstrain around all implants. The cantilever extensions in premolar (5 mm) in addition of having the smallest microstrain values compared the extent to molar (15mm) also showed the highest maximum load values to fracture
|
269 |
Estudo comparativo das tensões e microdeformações ao redor de pilares protéticos microunit e ucla sob carregamento axial estáticoSantis, Leandro Ruivo de [UNESP] 03 December 2015 (has links) (PDF)
Made available in DSpace on 2016-04-01T17:55:16Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-12-03. Added 1 bitstream(s) on 2016-04-01T18:01:17Z : No. of bitstreams: 1
000860699.pdf: 2264641 bytes, checksum: 4f5c8ea2c3254608562a9141ab7a55ca (MD5) / O objetivo deste estudo in vitro foi comparar a microdeformação e a concentração de tensões ao redor de implantes, geradas por cargas axiais estáticas, em pilares protéticos microunit e ucla, por meio da extensometria e fotoelasticidade. Foram confeccionados dois blocos em poliuretano, sendo inseridos três implantes de hexágono externo em cada. Os implantes do primeiro bloco receberam pilares protéticos microunit e, nos implantes do segundo bloco, foram instalados pilares protéticos ucla. As respectivas coifas plásticas foram posicionadas sobre os pilares protéticos microunit. As coifas plásticas microunit e ucla foram adaptadas a uma estrutura em resina padronizada e fundidas em liga Ni-Cr. Os blocos foram duplicados em resina fotoelástica. As supraestruturas metálicas foram parafusadas sobre os respectivos pilares protéticos. Os blocos fotoelásticos foram submetidos a uma carga axial de 7,5 kgf usando um dispositivo de aplicação de carga adaptado em polariscópio. Foram colados quatro extensômetros na superfície superior de cada bloco em poliuretano, tangenciando cada um dos implantes. Foi utilizado um dispositivo de aplicação de cargas com carga axial de 30 kgf sobre os pontos A, B e C, durante 10 segundos. Os dados obtidos foram analisados estatisticamente através do teste RM ANOVA dois fatores e teste post hoc de Sidak (p<0,05). Os pilares protéticos ucla apresentaram menores valores médios de microdeformação (597,8 με), quando comparado aos pilares protéticos microunit (988,3 με). O fator pilar foi estatisticamente significante (p <0,0001), o ponto de aplicação da carga não foi estatisticamente significante (p = 0,9437). Os pilares protéticos ucla mostraram padrões de distribuição de tensão semelhantes aos pilares protéticos microunit. O padrão de distribuição das tensões foi diferente no ponto de aplicação de carga B. Em conclusão, a p presença de pilar prótetico convencional interferiu.... / The aim of this in vitro study was to compare microstrain and stress development around implants during axial loading, varying abutment type and load application point, using strain gauge and photoelastic analysis. Two polyurethane blocks were made, being inserted three external hexagon implants each. Microunit abutments were screwed on the first block and UCLA abutments were screwed on the second block. The respective plastic copings were installed onto the microunit abutments. The plastic copings and UCLA abutments were adapted to a standard resin pattern and cast in Ni-Cr alloy. The blocks were replicated in photoelastic resin. The metallic structures were screwed into the microunit abutments and into the implant plataform, respectively. The photoelastic blocks were submitted to a static vertical 7,5 kgf load using a load application device adapted on polariscope. Four strain gauges were bonded to the surface of each polyurethane block, tangetially to each implant. A static vertical 30 kgf load was applied for 10 seconds, using a load application device on points A, B and C. The data were analyzed by two-way RM ANOVA and Sidak's post hoc test (p< 0.05). Ucla abutments showed lower microstrain mean values (597,8 με) when compared to microunit abutments (988,3 με). The abutment factor was statistically significant (p<0.0001), load application point wasn't statistically significant (p=0,9437). UCLA system showed similar stress distribution patterns to conventional abutments. The pattern of stress distribution was different at point B. In conclusion, the presence of conventional prosthetic pillar interfered in stress distribution and microstrain development
|
270 |
Avaliação da interface de cinco sistemas de implantes e seus respectivos abutments com auxílio do método de microscopia eletrônica de varreduraFujiwara, Carlos Alberto [UNESP] January 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:42Z (GMT). No. of bitstreams: 0
Previous issue date: 2005Bitstream added on 2014-06-13T20:55:05Z : No. of bitstreams: 1
fujiwara_ca_me_araca.pdf: 1023210 bytes, checksum: d5bfe58a6ad917370b05a41403af9e6f (MD5) / Universidade Estadual Paulista (UNESP) / A adaptação entre a plataforma do implante e seu respectivo abutment deve ser precisa, isto é, sem nenhuma fenda, que é denominada microgap, entre as estruturas. A presença do microgap permite que microorganismos presentes na microbiota bucal migrem para o interior do implante, o que pode ocasionar problemas de natureza inflamatória e ou infecciosa, e, conseqüentemente, causar a perda do implante. Neste estudo utilizamos uma amostragem de 26 (vinte e seis) implantes e seus respectivos abutments provenientes de 5 (cinco) marcas comerciais diferentes: AS Tecnology, Conexão Sistema de Prótese, Neodent Implante Osteointegrado, Sterngold Implamed, e 3i Implant Innovation. Os abutments receberam um torque de 20Ncm. Os cortes longitudinais da interface implante/abutment foram mensurados em 6 (seis) locais com o auxílio da microscopia eletrônica de varredura. Os resultados das mensurações foram submetidos à análise estatística. Foi possível concluir que: 1) A seqüência dos grupos, em relação ao gap encontrado, do menor para o maior, foram: abutment cônico, abutment gold ucla, abutment mult unit. 2) O abutment cônico e o abutment mult unit apresentaram gaps menores que o abutment gold ucla. 3) O ponto interno apresentou gap menor em relação ao ponto médio, o qual foi menor que o ponto externo, portanto, as peças tenderam a convergir para o ponto interno. / The adaptation of the implant platform and its respective abutment must be precise, with no space denominated microgap, between the structures. The presence of a microgap allows microorganisms that are present in the buccal microbiology to migrate into the implant, what could cause inflammatory and/or infectious problems, and consequent loss of the implant. In this study, a sample of 26 (twenty six) implants and their respective abutments was taken: conic, multi unit, and the gold ucla - together with their respective fixing screws. The abutments received a manual torque of 20Ncm. After the manual preparation, the interface implant/abutment longitudinal cuts were measured on 6 (six) different points through an Scanning Electron Microscope (SEM). The results of such measurements were statistically analyzed, and according to the experimental conditions of this study, was possible to conclude: 1) The sequential groups of implants/abutments, in relation to the gap found, from the smaller to the biggest, were: a) conic abutment , b) gold ucla abutment , c) multi unit abutment. 2) The conic and the multi unit abutments showed smaller gaps than the gold ucla abutments. 3) The internal point showed a smaller gap than the middle point, and the middle point, in return, also showed a smaller gap in relation to the external point; therefore, the pieces tended to converge to the internal point.
|
Page generated in 0.0885 seconds