• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 35
  • Tagged with
  • 35
  • 35
  • 35
  • 12
  • 11
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Análise fotoelástica de distribuição de tensões em implantes paralelos e em protocolo tipo all-on-four / Photoelastic analysis of stress distribution in parallel implants and protocol all-on-four

Zacarias Filho, Rachid Pinto 17 August 2018 (has links)
Orientador: Mauro Antônio de Arruda Nóbilo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-17T12:35:45Z (GMT). No. of bitstreams: 1 ZacariasFilho_RachidPinto_M.pdf: 3525548 bytes, checksum: ebb8dd31a42ac34d09f7027bc5fe19c4 (MD5) Previous issue date: 2010 / Resumo: O objetivo nesta pesquisa foi avaliar in vitro através da fotoelasticidade, as tensões induzidas em protocolos com implantes inclinados (conceito All-on-Four) e paralelos, utilizados em prótese sobre implantes mandibulares com infraestruturas confeccionadas em titânio, soldadas a laser e submetidos à carga distal. Os protocolos foram confeccionados com barras de titânio com 3 mm de diâmetro (Conexão Sistemas de Prótese - SP) soldados sobre 2 modelos-mestres em gesso especial (Durone-Dentsply) sendo: 1 modelo com quatro implantes dispostos de forma paralela (GP) e 1 modelo com quatro implantes, sendo dois mesiais dispostos de forma paralela e dois distais inclinados, instalados segundo o protocolo All-on-four (GI). A disposição dos implantes em número de quatro (GP) possuem perfurações eqüidistantes e paralelas entre si, seguindo a média do espaço intra-foramidal de acordo com o posicionamento encontrado para o sistema Branemark®. No caso do grupo inclinado (GI), a instalação dos quatro implantes foi feita segundo o guia All-on-four da Nobel Biocare®. Todos os implantes Master Screw (Conexão Sistemas de Prótese - SP) eram hexágonos externos e diâmetro regular (3,75mm X 13 mm). Foi confeccionado um modelo com três paredes planas, em resina fotoelástica (Araldite - Araltec) de cada um dos protocolos, permitindo a quantificação das tensões em cada implante, por meio da técnica fotoelástica de transmissão plana. Após carga de 100 Ncm sobre área de cantilever das infra-estruturas, as tensões foram registradas e analisadas em polariscópio circular acoplado a uma máquina fotográfica digital (Cyber-Shot DSC-717 - Sony) que captou as imagens. Os resultados evidenciaram que a infraestrutura do GI apresentou maior número de franjas especialmente sobre os implantes inclinados distais. O grupo com implantes paralelos demonstrou melhor distribuição das tensões após a aplicação do carregamento distal / Abstract: The aim of this study was to evaluate in vitro by photoelasticity, the stresses induced in inclined implant protocols (All-on-Four) and parallel, used in mandibular implant prosthesis with infrastructure made of titanium, laser welded and subjected distal load. The protocols were made of titanium bars with 3mm diameter (Conexao Sistemas de Protese - SP) soldiers on two models-masters in special gypsum (Dentsply-Durone) where: a model with four implants arranged in parallel (GP) and a model with four implants, two of them arranged in parallel mesial and two distal inclined, constructed according to the protocol All-on-four (GI). The provision of implants in number four (GP) have holes equidistant and parallel to each other, according to the average of the intra-foramidal according to the position found for the Branemark system ®. In the case of tilted group (IG), the installation of the four implants was made according to the guide All-on-four Nobel Biocare ®. All implants Master Screw (Conexao Sistemas de Protese - SP) were regular hexagons and external diameter (3.75 mm X 13 mm). A model was built with three flat walls in photoelastic resin (Araldite - Araltec) from each of the protocols, allowing the quantification of stress in each implant by means of technical transmission photoelastic flat. After loading about 100 Ncm cantilever area of infrastructure, the tensions were recorded and analyzed in a circular polariscope coupled to a digital camera (Cyber-Shot DSC-717 - Sony) that captured the images. The results showed that the infrastructure of GI presented more especially on the fringes inclined distal implants. The group with parallel implants showed better stress distribution after the application of distal loading / Mestrado / Protese Dental / Mestre em Clínica Odontológica
32

Protese parcial removivel de extremidade livre associada a um implante osseointegrado : estudo atraves do metodo dos elementos finitos

Rocha, Eduardo Passos 25 June 2001 (has links)
Orientador: Altair A. Del Bel Cury / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T23:43:29Z (GMT). No. of bitstreams: 1 Rocha_EduardoPassos_D.pdf: 4550295 bytes, checksum: 68320e2f849e4ffbb6731204012d540e (MD5) Previous issue date: 2001 / Resumo: Os dados sobre a associação entre os implantes osseointegrados e a prótese parcial removível de extremidade livre (PPREL) são poucos e inconclusivos. Devido a isso, foi objetivo deste trabalho avaliar através do método dos elementos finitos bidimensional (MEF) a distribuição das tensões nas estruturas de suporte da PPREL associada a um implante osseointegrado - Sistema Branemark - de 10,0 x 3,75 mm, localizado na porção distal do rebordo alveolar, atuando como suporte para a base da PPREL. Para isto, foram criados 3 modelos, que em corte sagital representaram: Modelo A (MA) - Hemiarcada contendo os dentes naturais 33 e 34, e ausência dos dentes 35, 36 e 37; Modelo B (MB) - Semelhante ao MA, com uma PPREL convencional, substituindo os dentes ausentes; Modelo C (MC) - Semelhante ao MB, com um implante na região posterior do rebordo, servindo como suporte. Com o auxílio do programa de elementos finitos, ANSYS 5.5, os modelos foram carregados com forças verticais de 50 N em cada ponta de cúspide. O mapa de tensões evidenciou máxima e mínima concentração de tensões de (MPa): MA (39,668 e 0,005); MB (72,430 e 0,736) e MC (205,662 e 0,057). O deslocamento máximo foi (em mm): MA (0,064); MB (0,107) e MC (0,099). A presença da PPREL (MB) solicitou mais as estruturas de suporte em comparação ao MA; a presença do implante (MC) permitiu níveis de tensão Menores na parte posterior do rebordo alveolar e níveis semelhantes no dente 34, suporte da PPREL, quando comparados aos valores do MB; com níveis elevados de tensão no corpo do implante. Conclui-se Que a presenca da PPREL proporcionou maiores valores de tensão para as estruturas de suporte e Que a presenca do implante osseointearado proporcionou suporte para a base da PPREL. diminuindo a intrusão desta sobre a fibromucosa. promovendo menores níveis de tensão na porcão posterior do rebordo / Abstract: Little is know about the association of osseointegrated implant with a distal extension removable partial denture (DERPD). In view of that, a two-dimensional finite element analysis (FEA) was carried out to study the association of Branemark implant 10. O x 3.75 mm with DERPD, located in the dista! portion of the alveolar edge, acting as support. For this, 3 plane strain models were created, represented in sagital cut: Model A (MA) - Hemiarc containing the natural teeths 33 and 34, and absence of the teeths 35. 36 and 37; Model B (MB) - Similar to MA, with a conventional DERPD; Model C (MC) Similar to MB, with one implant in the retromolar area. The models were loaded with vertical forces of 50 N in finite element program, ANSYS 5.5. The stresses map showed for the maximum and the minimum von Mises stresses, the following values (Mpa), respectively: MA (39.668 and 0.005); MB 72.430 and 0.736) and MC (205.662 AND 0.057). The maximum displacement were (mm): MA (0.064); MB (0.107) and MC (0.099). The presence of DERPD (MB) requested more the support structures in comparison with the MA; the presence of implant (MC) allowed smaller stresses levels in the alveolar edge and similar levels in the tooth 34, support of RPD, when compared to the values of MB; and high levels of stress in the implant body. Thus. the presence of DERPD provided laraer stresses values for the support structures and that the presence of the implant provided support tor the DERPD base. reducina the intrusion on the fibromucosa. promotina smaller stresses levels in the subseauent portion of the edae / Doutorado / Protese Dental / Doutor em Clínica Odontológica
33

Analise fotoelastica da distribuição de tensões em implantes osseointegraveis com diferentes desenhos / Analyze fotoelastic the distribution of tensions in osseointegrables implants of different designs

Perez, Miguel Angel Jaimes 13 August 2018 (has links)
Orientador: Jose Ricardo de Albergaria Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T22:50:05Z (GMT). No. of bitstreams: 1 Perez_MiguelAngelJaimes_D.pdf: 10680088 bytes, checksum: c91b56bc63db2e1197b0228d1fc609d5 (MD5) Previous issue date: 2009 / Resumo: O objetivo deste estudo foi analisar qualitativa e quantitativamente a distribuição das tensões geradas em modelos fotoelásticos após a aplicação de cargas verticais de 150N, em implantes osseointegráveis de diferentes desenhos. Foram selecionados 3 implantes: I.) Serson Implant 3,75 x 13 mm, Hexágono Externo; II.) Colosso RC 4,0 x 13 mm, Hexágono Interno; III.) Kopp 4,0 x 13 mm, Cone Morse. Para a análise da distribuição de tensões foram confeccionadas 3 hemimandibulas em resina fotoelástica a partir da duplicação de três réplicas de hemimandibulas humanas de poliuretano. Cada implante foi posicionado e fixado no interior da hemimandibula fotoelástica na região do segundo pré-molar ausente. Através do polariscópio circular pertencente ao laboratório de Materiais Dentários da Faculdade de Odontologia de Piracicaba FOP-UNICAMP, foi possível visualizar as franjas isocromáticas nos modelos. Na análise qualitativa foi observado o início da primeira franja e a distribuição das tensões quando aplicado 150N de carga. A análise quantitativa foi obtida através da formula da lei ótica das tensões, conhecendo a respectiva ordem de franja no ponto de interesse, a constante ótica do material e a espessura do modelo. Este cálculo permitiu conhecer a tensão cisalhante de cada implante. O implante cilíndrico Serson, H.E apresentou distribuição das tensões na região cervical, apical e média do implante com maior tensão cisalhante na região cervical, seguido pela região media e apical. O implante Colosso RC com H.I apresentou distribuição das tensões na região apical, cervical e média do implante com um padrão uniforme de tensões nas três regiões. O implante Kopp, com desenho cônico e C.M apresentou distribuição das tensões na região cervical, apical, e média do implante com maior concentração de tensão cisalhante na região apical, seguido pela região cervical e media conjuntamente. Baseado nos resultados e na metodologia empregada neste estudo conclui-se que os três desenhos de implantes apresentaram padrões diferentes de distribuição de tensões, observando-se menor concentração de tensões nos implantes cônicos com conexões internas H.I e C.M. O implante cilíndrico com H.E apresentou maior concentração de tensão / Abstract: This study qualitatively and quantitatively analyze the distribution of tensions generated in fotoelastic models after the application of vertical loads of 150N in osseointegrables implants of different designs. We selected 3 implants: I.) Serson Implant 3.75 x 13 mm, External Hexagon II.) Colosso RC 4.0 x 13 mm, Internal Hexagon, III.) Kopp 4.0 x 13 mm, Morse Cone. For the analysis of the distribution of tensions, 3 hemimandibles using fotoelastic resin from the duplication of three replics of human hemimandibles of polyurethane were made. Each implant was placed and fixed inside the fotoelastic hemimandibles in the region where the second pre-molar was absent. Through a circular polariscope belonging to the Dental Materials, School of Dentistry of Piracicaba (FOP - UNICAMP) laboratory was able to see the isochromatics fringes in the models. In the qualitative analysis was observed the beginning of the first fringe and the distribution of the tensions when was applied a load of 150N. A quantitative analysis was obtained through the optical formula law of the tensions, knowing the order of fringe at the point of interest, an optical constant of the material and the thickness of the model. This calculation allowed to know the cisalhante shear of each implant. The cylindrical implant Serson HE showed distribution of the tensions in the cervical, middle and apical region of the implant with great tension shear in the cervical, followed by middle and apical region. The implant Colosso RC with HI showed distribution of the tensions in the apical, cervical and middle region of the implant with a uniform pattern of the tensions in these three regions. The implant Kopp with conic design and CM showed distribution of the tensions in the cervical, apical, and middle region of the implant with great concentration of the tension shear in the apical region, followed by cervical and middle together. Based on the results and methodology used in this study, we concluded that the three designs of implants showed different patterns of distribution of the tensions, with less concentration of the tensions in the conical implants with internal connections HI and CM. The cylindrical implant with HE showed higher concentration of the tension / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica
34

Influencia do desenho dos implantes endosseos na distribuição de tensões apos aplicação de cargas verticais e obliquas : analise estrutural e fotoelastica / Influence of dental implant design on tensions distribution after vertical and oblique loading : a structural and phtoelactic study

Perez, Miguel Angel Jaimes 18 July 2008 (has links)
Orientador: Jose Ricardo de Albergaria Barbosa / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-11T23:04:29Z (GMT). No. of bitstreams: 1 Perez_MiguelAngelJaimes_M.pdf: 6909101 bytes, checksum: 41413f644c388e8bd46795ab371670ee (MD5) Previous issue date: 2008 / Resumo: Este estudo teve como objetivo analisar a influência do desenho dos implantes endósseos na distribuição de tensões geradas nos modelos fotoelásticos após aplicação de cargas verticais e oblíquas a 7,5N, em quatro marcas comerciais de implantes endósseos. Foram selecionados doze implantes, divididos em quatro grupos: I.) Máster Conect Cônico1 4,3 x 13 mm; II.)Titamax Ti Medular2 3,75 x 13 mm; III.) Colosso3 RC 4,0 x 13mm; IV.) Bicon Uncoated Implant4 3,5 x 11mm, cada grupo contendo 3 implantes da mesma marca comercial. Através da Microscopia Eletrônica de Varredura foi analisado o desenho estrutural dos implantes. Para a análise da distribuição de tensão foram confeccionados oito modelos em resina fotoelástica com dimensões de 40 mm x 10 mm de base e 30 mm de comprimento. Dois implantes para cada grupo foram posicionados e fixados no interior dos modelos fotoelásticos. Uma vez verificada a ausência de tensões nos oito modelos foram iniciados os ensaios. Quatro modelos dos diferentes grupos receberam cargas verticais e quatro receberam cargas oblíquas de 7,5N. Por meio do polariscópio circular pertencente ao laboratório de Materiais Dentários e Prótese da USP-Riberão Preto, foi possível visualizar as franjas de tensões geradas nos modelos. Cada seqüência foi fotografada, sendo mantida a mesma distância focal em todos os ensaios. Os resultados obtidos foram analisados por grupos. O Grupo I, implante de hexágono interno longo com porção cervical polida, topo das roscas arredondadas, passos das roscas contínuas, espirais angulados e configuração cônica, apresentou concentração das tensões na região apical, quando submetida à carga vertical e oblíqua. O Grupo II, implante de hexágono externo, porção cervical polida, topo das roscas em forma de "v", passos das roscas contínuos, espirais anguladas e configuração cilíndrica, apresentou distribuição das tensões na região apical, médio e cervical do implante quando submetida à carga vertical e oblíqua. O Grupo III, implante com hexágono interno, porção cervical polida, topo das roscas em forma cônica, passos das roscas contínuos, espirais anguladas e configuração cilíndrica, apresentou distribuição das tensões nas regiões apical, médio e cervical do implante após aplicação de carga vertical e oblíqua. O Grupo IV, implante com sistema cone morse, ombro cervical inclinado, platô ou barbatanas, topo do platô quadradas, passos do platô descontinuais, e configuração cilíndrica, distribuiu as tensões nas regiões apical, médio e cervical do implante após aplicação de carga vertical e oblíqua. Baseado nos resultados obtidos e dentro da metodologia deste estudo conclui-se que: O grupo I, de configuração cônica concentrou a distribuição das tensões em região apical. Os grupo II, III e IV, de configuração cilíndrica, distribuíram as tensões com intensidade e localização similares nos terços apical médio e cervical. O presente estudo evidenciou haver diferenças na distribuição das cargas de um tipo de implante para outro, levando acreditar que essas diferenças possam ter relação com o desenho das roscas e platô. / Abstract: The meaning of this study was analyze on 4 dental implants brands the influence of its thread design on tensions distribution generated thru photoelastic models, after applying a 7.5N load on vertical and oblique directions. Twelve implants, organized in four groups had been selected: I.) Máster Conect Cônico1 4.3 x 13 mm; II.) Titamax Ti Medular2 3.75 x 13 mm; III.) 4,0 Colosso3 RC x 13mm; IV.) Bicon Uncoated Implant4 3.5 x 11mm, being in each group, three dental implants of the same commercial brand. The structural designs of the implants were analyzed with Electronic Microscopy Sweepings. For the tension distribution analysis, eight models had been confectioned in photoelastic resin with 40mm x 10mm base dimensions and 30 mm of length. Two implants of each group had been located and fixed in the interior of photoelastic models. Once verified the absence of tensions in the eight models the analysis were started. Four models of the different groups had received 7.5N load on vertical and four received this same load on oblique direction. By means of the circular polariscope developed in the Dental Materials and Prostheses laboratory the Ribeirão Preto Dental School (USP/RP), it was possible to visualize the tensions fringes generated in the models. Each sequence was photographed, being kept the same focal distance in all the assays. The gotten results had been analyzed by groups. Group I., implants with long internal hexagon and polishing cervical portion, top of rounded off threads, angled steps of continuous threads, spirals and conical configuration, presented tensions concentration on the apical region, when submitted to the vertical and oblique load. Group II, implants with external hexagon, polishing cervical portion, top of threads in form of v, angled steps of continuous threads, spirals and cylindrical configuration, presented tensions distribution on the apical, medial and cervical regions of the dental implants, when submitted to the vertical and oblique load. Group III., implants with internal hexagon, polishing cervical portion, top of threads in conical form, steps of threads continuous, spirals angled and cylindrical configuration, presented tensions distribution on the apical, medial and cervical regions . Group IV, implants with cone morse system, inclined cervical shoulder, square shaped threads, fin or plateau, angled plateau steps discontinuous, and cylindrical configuration, distributed the tensions on the apical, medial and cervical regions after the application of vertical and oblique loads. Based in the results gotten and respecting the limitations of this study it can be concluding that: Group I. with conical configuration, the tension distributions is concentrated on the apical region. Groups II, III and IV, with cylindrical configuration, had distributed the tensions with similar intensity and localization on the apical, medial and cervical regions. In the present study it is evidenced to have differences in the distribution of loads on the dental implants analyzed, being not evident that these differences have relation with the threads design. / Mestrado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Mestre em Clínica Odontológica
35

Estudo comparativo dimensional e da resistencia mecanica de dois sitemas nacionais de distratores osteogenicos alveolares justa-osseos

Freire Filho, Francisco Wagner Vasconcelos 12 October 2003 (has links)
Orientador: Jose Ricardo de Albergaria Barbosa / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T23:42:34Z (GMT). No. of bitstreams: 1 FreireFilho_FranciscoWagnerVasconcelos_D.pdf: 1185958 bytes, checksum: d471fe34fa012fb2c3725a04c776609d (MD5) Previous issue date: 2004 / Resumo: O objetivo deste trabalho foi comparar dois sistemas de distratores osteogênicos alveolares justa-ósseos de 9mm de abertura máxima de fabricação nacional. Foram analisadas duas marcas comerciais (Grupo I e Grupo II), através das avaliações dimensionais dos distratores e parafusos, da resistência à tração dos distratores e da resistência à flexão e à torção dos parafusos. Na avaliação dimensional foram utilizados dez distratores de cada fabricante e quarenta parafusos, sendo dez de cada tamanho oferecido, 1,3 x 5mm e 1,3 x 7mm do grupo I e 1,5 x 5mm e 1,5 x 7mm do grupo II. Os dados foram submetidos ao teste dos postos assinalados de Wilcoxon para os distratores e o teste de Friedman para os parafusos. No teste de resistência à tração foram utilizados dez distratores de cada marca comercial e os resultados submetidos ao teste t Student. No teste de resistência à flexão foram utilizados quarenta parafusos e aplicados os testes F e de Tukey, ao nível de significância de 5%. No teste de resistência à torção, foram utilizados dez parafusos de cada fabricante, sendo do tipo 1,3 x 5mm do grupo I e 1,5 x 5mm do grupo II e os resultados submetidos ao teste t Student. Os distratores do grupo II apresentaram menor variação das mensurações realizadas, porém não houve diferença estatística entre os parafusos de ambas as marcas. Os distratores do grupo II foram estatisticamente mais resistentes à tração. Os parafusos de 1,5x5mm do grupo II foram os mais resistentes à flexão e à torção / Abstract: The aim of this study was to perform a comparative analysis between two different alveolar distractions devices, of 9mm length, built by manufactured in Brazil. These two different devices were provided by companies (group I and group II). The analysis consisted of a macroscopic assessment from the distraction devices and its screws, followed by a traction resistance of the devices and torsion and bending resistance of the screws. Were used, for macroscopic assessment, ten distraction devices and forty screws, which included ten screws of every length offered by each company. Data was submitted to the Wilcoxon test for devices and Friedman test for screws. Ten distraction devices from each company were used for the traction resistance, and its results were submitted to the Student t test. Forty screws were used for the bending resistance. Values were compared trough F and Tukey test, with 5% significance. For the torsion resistance, ten screws from each company were used. The 1.3 X 5mm screws from group I and the 1.5 X 5mm from group II were chose to realize this test, and its results were submitted to the Student t test. Devices from group II presented less variation of its measurements, but there were not any statistical difference between the screws. Group II devices were tatistically more resistant to traction. Screws 1.5x5mm, produced by group II, were more resistant to bending and to torsion / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica

Page generated in 0.083 seconds