• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 4
  • 1
  • Tagged with
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Evaluation of dental implant materials and interactions with calcium phosphate solutions

Murphy, Matthew January 2016 (has links)
In this thesis, four experimental studies are reported. Two concern the surface structure of commercially relevant dental implant materials. Characterisation of four treated substrates supplied by Straumann AG was carried out. These include substrates equivalent to the commercially available SLA, SLActive and Roxolid implants. The materials vary in substrate alloy, commercially pure (grade 2) Ti and a TiZr alloy, and surface preparation treatments. All substrates are sandblasted and acid etched however post-etching one set are stored in air whilst the others are stored in saline. Within the work both substrate composition and surface treatment is shown to impact on the respective surface oxide thickness, crystallinity and morphology. The other two experimental studies concern calcium phosphate deposition from solution onto substrates. The first investigation is the deposition of calcium phosphate from a simulated body fluid onto implant-like substrates, shown to be structurally equivalent to the SLA and SLActive implant surfaces. The effect of surface modifications on calcium phosphate deposition is investigated; over the period investigated calcium phosphate did not deposit onto the SLA substrate, whilst deposition occurred within 3 days on the SLActive substrate. The role of Mg2+ ions in the simulated body fluid is also investigated, with increased [Mg2+] resulting in a longer induction period and modified crystallinity of the hydroxyapatite film formed. The final study is a model study of the initial calcium phosphate deposition on to substrates. TiO2 rutile (110) and Al2O3 corundum (0001) were prepared to be atomically flat and then exposed to a simple calcium phosphate solution. Changes in surface structure and surface chemistry over the first three hours of exposure were investigated. Deposition occurred rapidly on both substrates with a complete surface coverage after 3 hours.
2

Análise microbiológica da peri-implantite induzida por ligadura em diferentes superfícies de implantes osseointegrados: estudo em cães

Shibli, Jamil Awad [UNESP] 17 April 2000 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-04-17Bitstream added on 2014-06-13T20:17:45Z : No. of bitstreams: 1 shibli_ja_me_arafo.pdf: 739694 bytes, checksum: 57c9b17fc168fc0329fc6f5001a03672 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / A microbiota presente na peri-implantite induzida por ligadura, em diferentes superfícies de implantes osseointegrados, foi analisada em 6 cães adultos machos. 36 implantes osseointegrados (9 Ticp: titânio comercialmente puro; 9 TPS: titânio plasma spray; 9 HA: hidroxiapatita; 9 superfícies tratadas com ácidos) foram inseridos e distribuídos igualmente 3 meses após exodontia de todos os pré-molares inferiores. Após um período de 3 meses de osseointegração, os implantes receberam os cicatrizadores. Decorridos 45 dias de cicatrização, amostras peri-implantares foram colhida, utilizando pontas de papel, no período 0 e após a colocação de ligaduras com fio de algodão, nos períodos 20, 40 e 60 dias. A contagem total de microrganismos (CTM) e a proporação de A. actinomycetemcomitans, Bacteroides forsythus, P. gingivalis, P. intermedia, Campylobacter sp, Capnocytophaga sp., Fusobacterium sp., Peptostreptococcus micros, bastonetes anaeróbios Gram-negativos, Streptococcus beta-hemolíticos, Eikenella corrodens e Candida sp. foram analisadas. Não houve diferença da CTM entre as diferentes superfícies (p>0,05). A Pg não foi detectada no tempo 0; nos tempos 20 e 40 foi detectada em 12 implantes (4 Ticp, 4 HA, 2 TPS e 1 Sup. Trat. com ácidos) e no período 60 dias, em 9 (2 Ticp, 3 HA, 2 TPS e 1 Sup. Trat. com ácidos), tendo menor afinidade à superfície tratada com ácidos. Pi foi detectada em 5 implantes (2 Ticp, 2 HA e 1 Sup. Trat. com ácidos) no período 0 e em 100% dos implantes nos demais períodos. Fusobacterium sp. foi detectado em todos os períodos, tendo uma maior afinidade à HA. Streptococcus beta-hemolíticos foi detectado em 6 implantes (3 Ticp, 1 TPS e 2 HA) no período 0 e 30, 26 e 24 implantes respectivamente nos períodos 20, 40 e 60. Campylobacter sp. e Candida sp. foram detectadas em baixas proporções. Os demais microrganismos não... . / The microbiota associated with ligature-induced peri-implantitis, in different dental implants surfaces, was investigated by cultivation on enriched non-selective and various selective solid media, in 6 mongrel dogs. 36 dental implants (9 Ticp: titanium commercially pure; 9 TPS: titanium plasma spray; 9 HA: hidroxiapatite; 9 surfaces acid-etched) were placed in a similar distribution in all dogs 3 months after extraction of all premolars in mandible. Following a healing period of 3 months, healing abutments were installed and 45 days after cotton ligatures were placed and oral-cleaning procedures abolished for 2 months to induce vertical bone loss of about 40%. Microbial samples were with paper points on day of ligature placement and after 20, 40 and 60 days. The total number of cultivable bacteria and proportions of A. actinomycetemcomitans, Bacteroides forsythus, P. gingivalis, P. intermediate, Campylobacter sp., Capnocytophaga sp., Fusobacterium sp., Peptostreptococcus micros, Enteric Gram-negative rods, beta-hemolytic Streptococcus, Eikenella corrodens and Candida sp. were analyzed. No significant microbiological differences were observed among the different surfaces (p>0,05). Pg was not detected in the time 0; already in the times 20 and 40 were detected in 12 dental implants (4 Ticp, 4 HA, 2 TPS and 1 acid-etched surface) and in the period 60 days, in 9(2 Ticp, 3 HA, 2 TPS and 1 acid-etched surface), tends smaller affinity to eh surface with acids-etched surface. Pi was detected in 5 implants (2 Ticp, 2 HA and 1 acid-etched surface) in the period 0 and in 100% of implants in other periods. Fusobacterium sp. was detected in all the periods, tends a larger affinity to HA. Beta-hemolytic Streptococcus was detected in 6 implants (3 Ticp, 1 TPS and 2 HA) in the period 0 and 30, 26 and 24... (Complete abstract, click electronic address below).
3

Desenvolvimento da peri-implantite induzida por ligadura em diferentes superfícies de implantes osseointegrados. Análise clínica e radiográfica em cães

Martins, Marilia Compagnoni [UNESP] 26 April 2000 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:03Z (GMT). No. of bitstreams: 0 Previous issue date: 2000-04-26Bitstream added on 2014-06-13T20:27:59Z : No. of bitstreams: 1 martins_mc_me_arafo.pdf: 1209084 bytes, checksum: 7b11e93ab4898fd54b0df7617be967e1 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Foram avaliados, clínica e radiograficamente, as reações de quatro diferentes superfícies de implante frente ao desenvolvimento e progressão da peri-implantite: Ticp: titânio comercialmente puro; TPS: titânio revestido com plasma spray de titânio; HA: hidroxiapatita; Ost. Superfícies tratadas com ácidos. Para tanto, foram utilizados seis cães, cujos pré-molares inferiores e superiores foram extraídos. Decorridos 90 dias, os implantes foram aleatoriamente colocados, e iniciou-se o controle químico e mecânico do biofilme bacteriano; após o período de osseointegração (90 dias) foram colocados os conectores, e após 45 dias da colocação dos conectores, iniciou-se a indução da peri-implantite por meio de ligaduras de fio de algodão (suspensão do controle do biofilme bacteriano), e os primeiros exames clínicos (profundidade de sondagem, sangramento à sondagem, índices de placa e sangramento, e mobilidade) e radiográficos (perda óssea) foram realizados. Esses parâmetros foram novamente avaliados após 20, 40 e 60 dias, quando da troca das lidaguras. A análise dos resultados não demonstrou diferença significante entre as superfícies, em nenhum dos parâmetros analisados, com exceção da mobilidade (avaliada pelo PeriotestÒ) e perda óssea, que foram menores nos implantes TPS. Concluiu-se que as superfícies apresentam comportamento semelhante durante a indução da peri-implantite, com exceção no parâmetros mobilidade e perda óssea, que apresentaram os implantes TPS com comportamento superior. / The reactions of four different implant surfaces were evaluated in regard to the development and progression of peri-implantitis: titanium commercially pure (Ticp), titanium plasma spray (TPS) hidroxiapatite coated (HA) and acid attached surfaces (Ost). Six dogs had their premolars extracted. After 90 days, the implants were ramdonly placed and the dogs receive soft diet, chemical and mechanical plaque control; after the osseointegration period (90 days), the healing abutments were placed. After the healing period (45 days), the plaque control was suspended, and cotton ligatures were installed when the first clinical (probing depth, bleeding on probing, plaque index, bleeding index, and mobility) and radiographic (bone loss) exams were taken. These parameters were re-exanimate after 20, 40 and 60 days, when the ligatures were changed. The results did not show significant differences between the surfaces in any parameter observed except for the mobility (evaluated with PeriotestÒ), and bone loss. These two parameters had the TPS surface with the lower rates. It was conclude that the surfaces show similar behavior during the induction of peri-implantitis, except for the mobility and bone loss parameters witch the TPS implants had better behavior.
4

Análise microbiológica da peri-implantite induzida por ligadura em diferentes superfícies de implantes osseointegrados: estudo em cães /

Shibli, Jamil Awad. January 2000 (has links)
Orientador: Elcio Marcantonio Junior / Banca: Izabel Yoko Ito / Banca: Roberto Fraga Moreira Lotufo / Resumo: A microbiota presente na peri-implantite induzida por ligadura, em diferentes superfícies de implantes osseointegrados, foi analisada em 6 cães adultos machos. 36 implantes osseointegrados (9 Ticp: titânio comercialmente puro; 9 TPS: titânio plasma spray; 9 HA: hidroxiapatita; 9 superfícies tratadas com ácidos) foram inseridos e distribuídos igualmente 3 meses após exodontia de todos os pré-molares inferiores. Após um período de 3 meses de osseointegração, os implantes receberam os cicatrizadores. Decorridos 45 dias de cicatrização, amostras peri-implantares foram colhida, utilizando pontas de papel, no período 0 e após a colocação de ligaduras com fio de algodão, nos períodos 20, 40 e 60 dias. A contagem total de microrganismos (CTM) e a proporação de A. actinomycetemcomitans, Bacteroides forsythus, P. gingivalis, P. intermedia, Campylobacter sp, Capnocytophaga sp., Fusobacterium sp., Peptostreptococcus micros, bastonetes anaeróbios Gram-negativos, Streptococcus beta-hemolíticos, Eikenella corrodens e Candida sp. foram analisadas. Não houve diferença da CTM entre as diferentes superfícies (p>0,05). A Pg não foi detectada no tempo 0; nos tempos 20 e 40 foi detectada em 12 implantes (4 Ticp, 4 HA, 2 TPS e 1 Sup. Trat. com ácidos) e no período 60 dias, em 9 (2 Ticp, 3 HA, 2 TPS e 1 Sup. Trat. com ácidos), tendo menor afinidade à superfície tratada com ácidos. Pi foi detectada em 5 implantes (2 Ticp, 2 HA e 1 Sup. Trat. com ácidos) no período 0 e em 100% dos implantes nos demais períodos. Fusobacterium sp. foi detectado em todos os períodos, tendo uma maior afinidade à HA. Streptococcus beta-hemolíticos foi detectado em 6 implantes (3 Ticp, 1 TPS e 2 HA) no período 0 e 30, 26 e 24 implantes respectivamente nos períodos 20, 40 e 60. Campylobacter sp. e Candida sp. foram detectadas em baixas proporções. Os demais microrganismos não... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: The microbiota associated with ligature-induced peri-implantitis, in different dental implants surfaces, was investigated by cultivation on enriched non-selective and various selective solid media, in 6 mongrel dogs. 36 dental implants (9 Ticp: titanium commercially pure; 9 TPS: titanium plasma spray; 9 HA: hidroxiapatite; 9 surfaces acid-etched) were placed in a similar distribution in all dogs 3 months after extraction of all premolars in mandible. Following a healing period of 3 months, healing abutments were installed and 45 days after cotton ligatures were placed and oral-cleaning procedures abolished for 2 months to induce vertical bone loss of about 40%. Microbial samples were with paper points on day of ligature placement and after 20, 40 and 60 days. The total number of cultivable bacteria and proportions of A. actinomycetemcomitans, Bacteroides forsythus, P. gingivalis, P. intermediate, Campylobacter sp., Capnocytophaga sp., Fusobacterium sp., Peptostreptococcus micros, Enteric Gram-negative rods, beta-hemolytic Streptococcus, Eikenella corrodens and Candida sp. were analyzed. No significant microbiological differences were observed among the different surfaces (p>0,05). Pg was not detected in the time 0; already in the times 20 and 40 were detected in 12 dental implants (4 Ticp, 4 HA, 2 TPS and 1 acid-etched surface) and in the period 60 days, in 9(2 Ticp, 3 HA, 2 TPS and 1 acid-etched surface), tends smaller affinity to eh surface with acids-etched surface. Pi was detected in 5 implants (2 Ticp, 2 HA and 1 acid-etched surface) in the period 0 and in 100% of implants in other periods. Fusobacterium sp. was detected in all the periods, tends a larger affinity to HA. Beta-hemolytic Streptococcus was detected in 6 implants (3 Ticp, 1 TPS and 2 HA) in the period 0 and 30, 26 and 24... (Complete abstract, click electronic address below). / Mestre
5

Desenvolvimento da peri-implantite induzida por ligadura em diferentes superfícies de implantes osseointegrados. Análise clínica e radiográfica em cães /

Martins, Marilia Compagnoni. January 2000 (has links)
Resumo: Foram avaliados, clínica e radiograficamente, as reações de quatro diferentes superfícies de implante frente ao desenvolvimento e progressão da peri-implantite: Ticp: titânio comercialmente puro; TPS: titânio revestido com plasma spray de titânio; HA: hidroxiapatita; Ost. Superfícies tratadas com ácidos. Para tanto, foram utilizados seis cães, cujos pré-molares inferiores e superiores foram extraídos. Decorridos 90 dias, os implantes foram aleatoriamente colocados, e iniciou-se o controle químico e mecânico do biofilme bacteriano; após o período de osseointegração (90 dias) foram colocados os conectores, e após 45 dias da colocação dos conectores, iniciou-se a indução da peri-implantite por meio de ligaduras de fio de algodão (suspensão do controle do biofilme bacteriano), e os primeiros exames clínicos (profundidade de sondagem, sangramento à sondagem, índices de placa e sangramento, e mobilidade) e radiográficos (perda óssea) foram realizados. Esses parâmetros foram novamente avaliados após 20, 40 e 60 dias, quando da troca das lidaguras. A análise dos resultados não demonstrou diferença significante entre as superfícies, em nenhum dos parâmetros analisados, com exceção da mobilidade (avaliada pelo PeriotestÒ) e perda óssea, que foram menores nos implantes TPS. Concluiu-se que as superfícies apresentam comportamento semelhante durante a indução da peri-implantite, com exceção no parâmetros mobilidade e perda óssea, que apresentaram os implantes TPS com comportamento superior. / Abstract: The reactions of four different implant surfaces were evaluated in regard to the development and progression of peri-implantitis: titanium commercially pure (Ticp), titanium plasma spray (TPS) hidroxiapatite coated (HA) and acid attached surfaces (Ost). Six dogs had their premolars extracted. After 90 days, the implants were ramdonly placed and the dogs receive soft diet, chemical and mechanical plaque control; after the osseointegration period (90 days), the healing abutments were placed. After the healing period (45 days), the plaque control was suspended, and cotton ligatures were installed when the first clinical (probing depth, bleeding on probing, plaque index, bleeding index, and mobility) and radiographic (bone loss) exams were taken. These parameters were re-exanimate after 20, 40 and 60 days, when the ligatures were changed. The results did not show significant differences between the surfaces in any parameter observed except for the mobility (evaluated with PeriotestÒ), and bone loss. These two parameters had the TPS surface with the lower rates. It was conclude that the surfaces show similar behavior during the induction of peri-implantitis, except for the mobility and bone loss parameters witch the TPS implants had better behavior. / Orientador: Ricardo Samih Georges Abi Rached / Coorientador: Elcio Marcantonio Junior / Banca: Rosemary Adriana Chiérice Marcantonio / Banca: Luiz Antonio Pugliesi Alves de Lima / Mestre
6

Surface Modifications of Orthopedic Implants for Improved Performance

Cipa, Esra January 2015 (has links)
No description available.

Page generated in 0.0612 seconds