• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • Tagged with
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Um estudo de uso de gradador de tensão em motores de indução monofásicos

Pauletti, Luiz Celestino January 2009 (has links)
O motor de indução é, talvez, o mais robusto e, certamente, um dos motores mais comumente usados. Graças à simplicidade de sua construção, do seu baixo custo, confiabilidade e rendimento relativamente alto com carga nominal é provável que ele permaneça sendo a principal fonte de transformação de energia elétrica em energia mecânica nas aplicações industriais e comerciais por um futuro previsível. O estudo de economia de energia pela redução de perdas é o objetivo do presente estudo. Os motores de indução operam regularmente com fluxo quase constante no entreferro e, portanto, com perdas magnéticas quase constantes. A utilização de um circuito gradador de tensão em série com a alimentação do motor para reduzir o fluxo no entreferro pela redução da tensão aplicada quando a carga não requer fluxo total é o objeto de análise neste estudo. Com a redução da tensão, para manter o conjugado de operação, a velocidade de rotação diminui, ou seja, há um aumento no escorregamento até um valor ótimo para reduzir as perdas totais. Então, esperaria-se que com a redução da tensão aplicada, as perdas magnéticas decresceriam e a eficiência total cresceria. Via de regra, no motor de indução, dada a característica mergulhante de sua curva Conjugado x Velocidade na região em torno da velocidade nominal, o conjugado varia muito mais que a velocidade. Para operação eficiente, a sua tensão aplicada deve ser função da carga que traciona. É objetivo desse trabalho estudar um dispositivo que, colocado em série com a fonte de alimentação de um motor de indução de CA, promove a redução de potência fornecida ao motor, quando a carga aplicada ao motor é menor que a carga nominal. Uma análise da redução da tensão senoidal aplicada através de um auto-transformador de tensão variável é comparada com a redução da tensão através de um circuito gradador baseado em tiristores. A melhor tensão a ser obtida é a que reduz as perdas magnéticas ao mínimo, para cargas que não requerem o fluxo total no entreferro como quando da tensão nominal aplicada. As limitações do processo são estudadas e apresentadas. / The induction motor is perhaps the most rugged, and certainly one of the most commonly used motors. With simply construction, low cost, reliability and efficiency relatively high with rated-load it seems to be a good way to convert electric energy into mechanical energy for industrial and domestic applications for a predictable future. An economy in energy consumption by loss reduction is the goal of this study. The induction motors as normal operate with constant flux in the air-gap and, hence with almost constant losses in the core. The use of a voltage gradador circuit in series with the voltage source applied to the motor for flux reduction in the air-gap by reduction of the voltage when the load do not need full-flux is this study proposal. Hence, with applied voltage reduction, to keep the operational torque, the motor rotation decreases or the slip increases to an optimum value to reduce the total core losses and increase the efficiency. As a rule, the induction motor, by the dip characteristic of the torque x speed curve in the region near the nominal speed, the torque changes much more then the speed. For efficient operation, the applied voltage should be a function of the load. It is the goal or aim of this work to study a device which, when placed in series with the power input of an alternating current induction motor, will produce a reduction in power normally provided to the motor when operated in either a condition where motor loading is less than a rated load. An analysis of voltage ideal sine wave supply reduction applied by an autotransformer with variable voltage is compared with the voltage reduction using a gradador circuit based on thyristors. The optimal voltage operation is the one that decrease the iron losses to minimum, for partial-load that do not need full-flux in the air-gap as when the full voltage is applied. Limitations in the process are investigated and will be showed.
2

Um estudo de uso de gradador de tensão em motores de indução monofásicos

Pauletti, Luiz Celestino January 2009 (has links)
O motor de indução é, talvez, o mais robusto e, certamente, um dos motores mais comumente usados. Graças à simplicidade de sua construção, do seu baixo custo, confiabilidade e rendimento relativamente alto com carga nominal é provável que ele permaneça sendo a principal fonte de transformação de energia elétrica em energia mecânica nas aplicações industriais e comerciais por um futuro previsível. O estudo de economia de energia pela redução de perdas é o objetivo do presente estudo. Os motores de indução operam regularmente com fluxo quase constante no entreferro e, portanto, com perdas magnéticas quase constantes. A utilização de um circuito gradador de tensão em série com a alimentação do motor para reduzir o fluxo no entreferro pela redução da tensão aplicada quando a carga não requer fluxo total é o objeto de análise neste estudo. Com a redução da tensão, para manter o conjugado de operação, a velocidade de rotação diminui, ou seja, há um aumento no escorregamento até um valor ótimo para reduzir as perdas totais. Então, esperaria-se que com a redução da tensão aplicada, as perdas magnéticas decresceriam e a eficiência total cresceria. Via de regra, no motor de indução, dada a característica mergulhante de sua curva Conjugado x Velocidade na região em torno da velocidade nominal, o conjugado varia muito mais que a velocidade. Para operação eficiente, a sua tensão aplicada deve ser função da carga que traciona. É objetivo desse trabalho estudar um dispositivo que, colocado em série com a fonte de alimentação de um motor de indução de CA, promove a redução de potência fornecida ao motor, quando a carga aplicada ao motor é menor que a carga nominal. Uma análise da redução da tensão senoidal aplicada através de um auto-transformador de tensão variável é comparada com a redução da tensão através de um circuito gradador baseado em tiristores. A melhor tensão a ser obtida é a que reduz as perdas magnéticas ao mínimo, para cargas que não requerem o fluxo total no entreferro como quando da tensão nominal aplicada. As limitações do processo são estudadas e apresentadas. / The induction motor is perhaps the most rugged, and certainly one of the most commonly used motors. With simply construction, low cost, reliability and efficiency relatively high with rated-load it seems to be a good way to convert electric energy into mechanical energy for industrial and domestic applications for a predictable future. An economy in energy consumption by loss reduction is the goal of this study. The induction motors as normal operate with constant flux in the air-gap and, hence with almost constant losses in the core. The use of a voltage gradador circuit in series with the voltage source applied to the motor for flux reduction in the air-gap by reduction of the voltage when the load do not need full-flux is this study proposal. Hence, with applied voltage reduction, to keep the operational torque, the motor rotation decreases or the slip increases to an optimum value to reduce the total core losses and increase the efficiency. As a rule, the induction motor, by the dip characteristic of the torque x speed curve in the region near the nominal speed, the torque changes much more then the speed. For efficient operation, the applied voltage should be a function of the load. It is the goal or aim of this work to study a device which, when placed in series with the power input of an alternating current induction motor, will produce a reduction in power normally provided to the motor when operated in either a condition where motor loading is less than a rated load. An analysis of voltage ideal sine wave supply reduction applied by an autotransformer with variable voltage is compared with the voltage reduction using a gradador circuit based on thyristors. The optimal voltage operation is the one that decrease the iron losses to minimum, for partial-load that do not need full-flux in the air-gap as when the full voltage is applied. Limitations in the process are investigated and will be showed.
3

Um estudo de uso de gradador de tensão em motores de indução monofásicos

Pauletti, Luiz Celestino January 2009 (has links)
O motor de indução é, talvez, o mais robusto e, certamente, um dos motores mais comumente usados. Graças à simplicidade de sua construção, do seu baixo custo, confiabilidade e rendimento relativamente alto com carga nominal é provável que ele permaneça sendo a principal fonte de transformação de energia elétrica em energia mecânica nas aplicações industriais e comerciais por um futuro previsível. O estudo de economia de energia pela redução de perdas é o objetivo do presente estudo. Os motores de indução operam regularmente com fluxo quase constante no entreferro e, portanto, com perdas magnéticas quase constantes. A utilização de um circuito gradador de tensão em série com a alimentação do motor para reduzir o fluxo no entreferro pela redução da tensão aplicada quando a carga não requer fluxo total é o objeto de análise neste estudo. Com a redução da tensão, para manter o conjugado de operação, a velocidade de rotação diminui, ou seja, há um aumento no escorregamento até um valor ótimo para reduzir as perdas totais. Então, esperaria-se que com a redução da tensão aplicada, as perdas magnéticas decresceriam e a eficiência total cresceria. Via de regra, no motor de indução, dada a característica mergulhante de sua curva Conjugado x Velocidade na região em torno da velocidade nominal, o conjugado varia muito mais que a velocidade. Para operação eficiente, a sua tensão aplicada deve ser função da carga que traciona. É objetivo desse trabalho estudar um dispositivo que, colocado em série com a fonte de alimentação de um motor de indução de CA, promove a redução de potência fornecida ao motor, quando a carga aplicada ao motor é menor que a carga nominal. Uma análise da redução da tensão senoidal aplicada através de um auto-transformador de tensão variável é comparada com a redução da tensão através de um circuito gradador baseado em tiristores. A melhor tensão a ser obtida é a que reduz as perdas magnéticas ao mínimo, para cargas que não requerem o fluxo total no entreferro como quando da tensão nominal aplicada. As limitações do processo são estudadas e apresentadas. / The induction motor is perhaps the most rugged, and certainly one of the most commonly used motors. With simply construction, low cost, reliability and efficiency relatively high with rated-load it seems to be a good way to convert electric energy into mechanical energy for industrial and domestic applications for a predictable future. An economy in energy consumption by loss reduction is the goal of this study. The induction motors as normal operate with constant flux in the air-gap and, hence with almost constant losses in the core. The use of a voltage gradador circuit in series with the voltage source applied to the motor for flux reduction in the air-gap by reduction of the voltage when the load do not need full-flux is this study proposal. Hence, with applied voltage reduction, to keep the operational torque, the motor rotation decreases or the slip increases to an optimum value to reduce the total core losses and increase the efficiency. As a rule, the induction motor, by the dip characteristic of the torque x speed curve in the region near the nominal speed, the torque changes much more then the speed. For efficient operation, the applied voltage should be a function of the load. It is the goal or aim of this work to study a device which, when placed in series with the power input of an alternating current induction motor, will produce a reduction in power normally provided to the motor when operated in either a condition where motor loading is less than a rated load. An analysis of voltage ideal sine wave supply reduction applied by an autotransformer with variable voltage is compared with the voltage reduction using a gradador circuit based on thyristors. The optimal voltage operation is the one that decrease the iron losses to minimum, for partial-load that do not need full-flux in the air-gap as when the full voltage is applied. Limitations in the process are investigated and will be showed.
4

On-line local load measurement based voltage instability prediction

Bahadornejad, Momen January 2005 (has links)
Voltage instability is a major concern in operation of power systems and it is well known that voltage instability and collapse have led to blackout or abnormally low voltages in a significant part of the power system. Consequently, tracking the proximity of the power system to an insecure voltage condition has become an important element of any protection and control scheme. The expected time until instability is a critical aspect. There are a few energy management systems including voltage stability analysis function in the real-time environment of control centres, these are based on assumptions (such as off-line models of the system loads) that may lead the system to an insecure operation and/or poor utilization of the resources. Voltage instability is driven by the load dynamics, and investigations have shown that load restoration due to the on-load tap changer (OLTC) action is the main cause of the voltage instability. However, the aggregate loads seen from bulk power delivery transformers are still the most uncertain power system components, due to the uncertainty of the participation of individual loads and shortcomings of the present approaches in the load modeling. In order to develop and implement a true on-line voltage stability analysis method, the on-line accurate modeling of the higher voltage (supply system) and the lower voltage level (aggregate load) based on the local measurements is required. In this research, using the changes in the load bus measured voltage and current, novel methods are developed to estimate the supply system equivalent and to identify load parameters. Random changes in the load voltage and current are processed to estimate the supply system Thevenin impedance and the composite load components are identified in a peeling process using the load bus data changes during a large disturbance in the system. The results are then used to anticipate a possible long-term voltage instability caused by the on-load tap changer operation following the disturbance. Work on the standard test system is provided to validate the proposed methods. The findings in this research are expected to provide a better understanding of the load dynamics role in the voltage stability, and improve the reliability and economy of the system operation by making it possible to decrease uncertainty in security margins and determine accurately the transfer limits.

Page generated in 0.1138 seconds