• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 3
  • 1
  • Tagged with
  • 4
  • 4
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Um estudo de uso de gradador de tensão em motores de indução monofásicos

Pauletti, Luiz Celestino January 2009 (has links)
O motor de indução é, talvez, o mais robusto e, certamente, um dos motores mais comumente usados. Graças à simplicidade de sua construção, do seu baixo custo, confiabilidade e rendimento relativamente alto com carga nominal é provável que ele permaneça sendo a principal fonte de transformação de energia elétrica em energia mecânica nas aplicações industriais e comerciais por um futuro previsível. O estudo de economia de energia pela redução de perdas é o objetivo do presente estudo. Os motores de indução operam regularmente com fluxo quase constante no entreferro e, portanto, com perdas magnéticas quase constantes. A utilização de um circuito gradador de tensão em série com a alimentação do motor para reduzir o fluxo no entreferro pela redução da tensão aplicada quando a carga não requer fluxo total é o objeto de análise neste estudo. Com a redução da tensão, para manter o conjugado de operação, a velocidade de rotação diminui, ou seja, há um aumento no escorregamento até um valor ótimo para reduzir as perdas totais. Então, esperaria-se que com a redução da tensão aplicada, as perdas magnéticas decresceriam e a eficiência total cresceria. Via de regra, no motor de indução, dada a característica mergulhante de sua curva Conjugado x Velocidade na região em torno da velocidade nominal, o conjugado varia muito mais que a velocidade. Para operação eficiente, a sua tensão aplicada deve ser função da carga que traciona. É objetivo desse trabalho estudar um dispositivo que, colocado em série com a fonte de alimentação de um motor de indução de CA, promove a redução de potência fornecida ao motor, quando a carga aplicada ao motor é menor que a carga nominal. Uma análise da redução da tensão senoidal aplicada através de um auto-transformador de tensão variável é comparada com a redução da tensão através de um circuito gradador baseado em tiristores. A melhor tensão a ser obtida é a que reduz as perdas magnéticas ao mínimo, para cargas que não requerem o fluxo total no entreferro como quando da tensão nominal aplicada. As limitações do processo são estudadas e apresentadas. / The induction motor is perhaps the most rugged, and certainly one of the most commonly used motors. With simply construction, low cost, reliability and efficiency relatively high with rated-load it seems to be a good way to convert electric energy into mechanical energy for industrial and domestic applications for a predictable future. An economy in energy consumption by loss reduction is the goal of this study. The induction motors as normal operate with constant flux in the air-gap and, hence with almost constant losses in the core. The use of a voltage gradador circuit in series with the voltage source applied to the motor for flux reduction in the air-gap by reduction of the voltage when the load do not need full-flux is this study proposal. Hence, with applied voltage reduction, to keep the operational torque, the motor rotation decreases or the slip increases to an optimum value to reduce the total core losses and increase the efficiency. As a rule, the induction motor, by the dip characteristic of the torque x speed curve in the region near the nominal speed, the torque changes much more then the speed. For efficient operation, the applied voltage should be a function of the load. It is the goal or aim of this work to study a device which, when placed in series with the power input of an alternating current induction motor, will produce a reduction in power normally provided to the motor when operated in either a condition where motor loading is less than a rated load. An analysis of voltage ideal sine wave supply reduction applied by an autotransformer with variable voltage is compared with the voltage reduction using a gradador circuit based on thyristors. The optimal voltage operation is the one that decrease the iron losses to minimum, for partial-load that do not need full-flux in the air-gap as when the full voltage is applied. Limitations in the process are investigated and will be showed.
2

Um estudo de uso de gradador de tensão em motores de indução monofásicos

Pauletti, Luiz Celestino January 2009 (has links)
O motor de indução é, talvez, o mais robusto e, certamente, um dos motores mais comumente usados. Graças à simplicidade de sua construção, do seu baixo custo, confiabilidade e rendimento relativamente alto com carga nominal é provável que ele permaneça sendo a principal fonte de transformação de energia elétrica em energia mecânica nas aplicações industriais e comerciais por um futuro previsível. O estudo de economia de energia pela redução de perdas é o objetivo do presente estudo. Os motores de indução operam regularmente com fluxo quase constante no entreferro e, portanto, com perdas magnéticas quase constantes. A utilização de um circuito gradador de tensão em série com a alimentação do motor para reduzir o fluxo no entreferro pela redução da tensão aplicada quando a carga não requer fluxo total é o objeto de análise neste estudo. Com a redução da tensão, para manter o conjugado de operação, a velocidade de rotação diminui, ou seja, há um aumento no escorregamento até um valor ótimo para reduzir as perdas totais. Então, esperaria-se que com a redução da tensão aplicada, as perdas magnéticas decresceriam e a eficiência total cresceria. Via de regra, no motor de indução, dada a característica mergulhante de sua curva Conjugado x Velocidade na região em torno da velocidade nominal, o conjugado varia muito mais que a velocidade. Para operação eficiente, a sua tensão aplicada deve ser função da carga que traciona. É objetivo desse trabalho estudar um dispositivo que, colocado em série com a fonte de alimentação de um motor de indução de CA, promove a redução de potência fornecida ao motor, quando a carga aplicada ao motor é menor que a carga nominal. Uma análise da redução da tensão senoidal aplicada através de um auto-transformador de tensão variável é comparada com a redução da tensão através de um circuito gradador baseado em tiristores. A melhor tensão a ser obtida é a que reduz as perdas magnéticas ao mínimo, para cargas que não requerem o fluxo total no entreferro como quando da tensão nominal aplicada. As limitações do processo são estudadas e apresentadas. / The induction motor is perhaps the most rugged, and certainly one of the most commonly used motors. With simply construction, low cost, reliability and efficiency relatively high with rated-load it seems to be a good way to convert electric energy into mechanical energy for industrial and domestic applications for a predictable future. An economy in energy consumption by loss reduction is the goal of this study. The induction motors as normal operate with constant flux in the air-gap and, hence with almost constant losses in the core. The use of a voltage gradador circuit in series with the voltage source applied to the motor for flux reduction in the air-gap by reduction of the voltage when the load do not need full-flux is this study proposal. Hence, with applied voltage reduction, to keep the operational torque, the motor rotation decreases or the slip increases to an optimum value to reduce the total core losses and increase the efficiency. As a rule, the induction motor, by the dip characteristic of the torque x speed curve in the region near the nominal speed, the torque changes much more then the speed. For efficient operation, the applied voltage should be a function of the load. It is the goal or aim of this work to study a device which, when placed in series with the power input of an alternating current induction motor, will produce a reduction in power normally provided to the motor when operated in either a condition where motor loading is less than a rated load. An analysis of voltage ideal sine wave supply reduction applied by an autotransformer with variable voltage is compared with the voltage reduction using a gradador circuit based on thyristors. The optimal voltage operation is the one that decrease the iron losses to minimum, for partial-load that do not need full-flux in the air-gap as when the full voltage is applied. Limitations in the process are investigated and will be showed.
3

Um estudo de uso de gradador de tensão em motores de indução monofásicos

Pauletti, Luiz Celestino January 2009 (has links)
O motor de indução é, talvez, o mais robusto e, certamente, um dos motores mais comumente usados. Graças à simplicidade de sua construção, do seu baixo custo, confiabilidade e rendimento relativamente alto com carga nominal é provável que ele permaneça sendo a principal fonte de transformação de energia elétrica em energia mecânica nas aplicações industriais e comerciais por um futuro previsível. O estudo de economia de energia pela redução de perdas é o objetivo do presente estudo. Os motores de indução operam regularmente com fluxo quase constante no entreferro e, portanto, com perdas magnéticas quase constantes. A utilização de um circuito gradador de tensão em série com a alimentação do motor para reduzir o fluxo no entreferro pela redução da tensão aplicada quando a carga não requer fluxo total é o objeto de análise neste estudo. Com a redução da tensão, para manter o conjugado de operação, a velocidade de rotação diminui, ou seja, há um aumento no escorregamento até um valor ótimo para reduzir as perdas totais. Então, esperaria-se que com a redução da tensão aplicada, as perdas magnéticas decresceriam e a eficiência total cresceria. Via de regra, no motor de indução, dada a característica mergulhante de sua curva Conjugado x Velocidade na região em torno da velocidade nominal, o conjugado varia muito mais que a velocidade. Para operação eficiente, a sua tensão aplicada deve ser função da carga que traciona. É objetivo desse trabalho estudar um dispositivo que, colocado em série com a fonte de alimentação de um motor de indução de CA, promove a redução de potência fornecida ao motor, quando a carga aplicada ao motor é menor que a carga nominal. Uma análise da redução da tensão senoidal aplicada através de um auto-transformador de tensão variável é comparada com a redução da tensão através de um circuito gradador baseado em tiristores. A melhor tensão a ser obtida é a que reduz as perdas magnéticas ao mínimo, para cargas que não requerem o fluxo total no entreferro como quando da tensão nominal aplicada. As limitações do processo são estudadas e apresentadas. / The induction motor is perhaps the most rugged, and certainly one of the most commonly used motors. With simply construction, low cost, reliability and efficiency relatively high with rated-load it seems to be a good way to convert electric energy into mechanical energy for industrial and domestic applications for a predictable future. An economy in energy consumption by loss reduction is the goal of this study. The induction motors as normal operate with constant flux in the air-gap and, hence with almost constant losses in the core. The use of a voltage gradador circuit in series with the voltage source applied to the motor for flux reduction in the air-gap by reduction of the voltage when the load do not need full-flux is this study proposal. Hence, with applied voltage reduction, to keep the operational torque, the motor rotation decreases or the slip increases to an optimum value to reduce the total core losses and increase the efficiency. As a rule, the induction motor, by the dip characteristic of the torque x speed curve in the region near the nominal speed, the torque changes much more then the speed. For efficient operation, the applied voltage should be a function of the load. It is the goal or aim of this work to study a device which, when placed in series with the power input of an alternating current induction motor, will produce a reduction in power normally provided to the motor when operated in either a condition where motor loading is less than a rated load. An analysis of voltage ideal sine wave supply reduction applied by an autotransformer with variable voltage is compared with the voltage reduction using a gradador circuit based on thyristors. The optimal voltage operation is the one that decrease the iron losses to minimum, for partial-load that do not need full-flux in the air-gap as when the full voltage is applied. Limitations in the process are investigated and will be showed.
4

Energy flow model for a scrapper conveyor unit / Energiflödesmodell till en skraptransportörsmodul

André, Meza Kahn January 2019 (has links)
Värmevärden AB is an energy company that distributes district heating. One of their challenges today is to reduce the energy losses and wear that occur in the plant's scrapper conveyor unit. The conveyor belt is in constant motion whether it is transporting fuel or going unloaded at idle. An understanding of the module's energy flow needs to be mapped. An energy flow behavior model for the scrapper conveyor unit is presented. The energy flow in the startup sequence when the belt runs at idle and at full load is simulated. The simulations visualize the velocity and acceleration of the belt as a function of time and the current flow in the engine when getting started. The model allows changes on various parameters such as engine velocity, current limitations, work efficiency and enables the calculation of necessary material to achieve a desired power delivery. With a current-limited engine of 140 [A], a lower acceleration is obtained as the belt transports the fuel masses. Energy losses are also reduced as the belt is started by their own mass when transportation is needed. This means that the wear on the components of the plant decreases as transportation takes a more controlled form. / Värmevärden AB är ett energibolag som distribuerar fjärrvärme. En av deras utmaningar idag är att minska energiförlusterna och slitaget som uppstår i anläggningens skrapstransportörs modul. Transportbandet är i konstant rörelse vare sig det transporterar bränsle eller går olastad i tomgång. Förståelse för modulens energiflöde behöver kartläggas. En beteendemodell för skraptransportörens modul presenteras. Genom analys av energiflödet i systemet simuleras startförloppet när bandet körs i tomgång och vid full last. Simuleringarna visualiserar bandets hastighet och acceleration som funktion av tid och även motorns strömförlopp under uppstartsfasen. Modellen tillåter ändringar på diverse parametrar såsom motorns varvtal, strömbegränsning, verkningsgrad och möjliggör även framräkningen av nödvändigt material för att uppnå en viss leverans uteffekt. Med en strömbegränsad motor på 140 [A] fås en lägre acceleration när bandet transporterar bränslemassorna. Energiförlusterna minskar också eftersom bandet sätts igång av massornas egenvikt när transporteringen behövs. Detta medför att slitaget på anläggningens komponenter minskar i och med att transporten sker i mera kontrollerade former.

Page generated in 0.0325 seconds