• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 35
  • 3
  • 1
  • Tagged with
  • 41
  • 41
  • 33
  • 32
  • 11
  • 10
  • 9
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Etude d'un procédé de dépollution basé sur le couplage ozone/charbon actif pour l'élimination des phtalates en phase aqueuse / Study of ozone/activated carbon process for the removal of phthalates in aqueous phase

Ferreira de Oliveira Penalver, Tatianne 15 December 2011 (has links)
Le respect des normes de rejets aqueux industriels imposées par la directive cadre sur l’eau (échéances en 2021) concernant les micropolluants, et notamment les phtalates, nécessite la mise au point de procédés de traitement innovants. L’étude du procédé basé sur le couplage ozone/charbon actif a ainsi été effectuée. Après la détermination des propriétés chimiques et texturales des charbons actifs testés, l’efficacité de ce couplage pour l’élimination des phtalates a été éprouvée selon plusieurs critères : cinétique d’élimination des polluants cibles, évolution de la minéralisation et de la toxicité au cours du traitement. La comparaison des résultats obtenus avec ceux de méthodes classiques (ozonation et adsorption seules) a mis en évidence le fort potentiel du couplage ozone/charbon actif, qui permet d’obtenir une élimination rapide des polluants ainsi qu’une minéralisation et une détoxification avancées dans toutes les conditions expérimentales testées. Ce couplage c’est aussi révélé efficace lors du traitement de matrices plus complexes, telle qu’une eau de sortie de station d’épuration. En outre, cette étude a permis de déterminer les propriétés chimiques et texturales du charbon actif favorisant ce procédé. Il a aussi été montré que ce matériau joue un rôle d’initiateur et de promoteur de radicaux libres (les réactions sont très majoritairement de nature radicalaire) ainsi que de support réactionnel. Enfin, cette étude a montré qu’une régénération in situ du matériau, économiquement très intéressante, pourrait être obtenue au cours du traitement. / In order to comply with the standards governing the discharge of industrial effluents (Water Framework Directive, target date 2021) concerning micropollutants, in particular phthalates, innovative wastewater treatment processes have to be used. The present research addresses this issue through a study of ozone/activated carbon coupling. After determining the textural and chemical properties of several activated carbons, the efficiency of this coupling for the removal of phthalates was tested according to the following criteria: degradation kinetics of the target pollutants and evolution of both toxicity and mineralization during the process. Compared to the classical methods (ozonation or adsorption used separately), coupling proved to be highly efficient. It enables the fast removal of pollutants with a significant decrease in mineralization and toxicity. Coupling also proved to be efficient for the treatment of more complex matrices such as municipal wastewater treatment outflow. Moreover, the activated carbon properties which favour the process have also been determined. It is shown that, in this coupling, the material acts as a radical initiator and promoter (the reactions are mainly radical in nature) and as a reaction support. Lastly, the study also shows that in situ regeneration of the activated carbon, which would be economically attractive, could be achieved during the process.
2

Técnicas aplicadas ao tratamento e redução dos efluentes líquidos de uma empresa de saneantes domissanitários

Peres, Silvana Drago January 2005 (has links)
A empresa estudada está sediada em Porto Alegre, RS, Brasil, e fabrica produtos de limpeza. Os efluentes provêm das águas de lavagens dos tanques e misturadores de produção, recipientes utilizados na separação de matérias-primas e da lavagem do próprio piso da fábrica, onde ocorrem derramamentos de produtos. Foi implantada uma estação de tratamento de efluentes que opera por processos físico-químicos de coagulação/floculação e adsorção. Entretanto, observou-se que era ineficiente para atender aos parâmetros de qualidade de água exigidos pela legislação. Assim, o objeto deste estudo foi minimizar a geração de efluentes e aperfeiçoar a operação da estação de tratamento dos efluentes líquidos da empresa. A metodologia de trabalho consistiu na caracterização do efluente industrial; monitoramento do desempenho da estação de tratamento de efluentes, implantação de mudanças no processo produtivo para verificar a possibilidade de minimização da geração de efluentes bem como da carga poluidora, e estudo de alternativas de tratamento para melhorar a qualidade da água. Os parâmetros avaliados foram pH, DQO, DBO, fósforo total, nitrogênio total, óleos e graxas, surfactantes, sólidos sedimentáveis e sólidos suspensos. Os resultados demonstram que o efluente apresenta pH alcalino, uma elevada carga orgânica, é rico em nitrogênio e fósforo e possui uma alta concentração de surfactantes. Entretanto, a implantação de um sistema de produção mais limpo, através da programação prévia do processo produtivo, e aplicação de novos procedimentos durante as operações de envase, permitiu que o volume de efluentes gerados diminuísse de 8 m3/dia para 6 m3/dia. A carga de poluente na ETE baixou significativamente, resultando em maior eficiência da estação de tratamento de efluentes. Assim, foi possível atingir, exata ou aproximadamente, todos os parâmetros de emissão padrão. O estudo das alternativas de tratamento também comprovou que o tratamento físicoquímico de coagulação/floculação é mais eficiente quando seguido de um tratamento de adsorção por carvão ativado. A fotocatálise heterogênea, com aplicação de luz UV como forma de polimento ao efluente, reduz substancialmente a quantidade de matéria orgânica e surfactantes presentes no efluente. Os valores da relação DBO/DQO, para o efluente tratado, que variam de 0,29 a 0,34, demonstram a possibilidade de degradação biológica, desde que haja aclimatação ou indução dos microrganismos. Esse fato abre a possibilidade de realizar o tratamento biológico do efluente industrial, misturado ou não ao esgoto cloacal gerado na empresa. / The company studied produces cleaning reagents and is located in Porto Alegre, RS, Brazil. The effluent comes from many washing operations, including equipment and ground cleaning. A physical-chemical treatment plant was installed. It is based on coagulation/flocculation and activated carbon adsorption. However, the treatment operation did not reach the water quality emission standards established by the legislation. Thus, the aim of this work was to minimize the effluent generation and to improve the effluent treatment plant efficiency. The methodology consisted of characterization of the industrial effluent, evaluation of effluent treatment plant, implantation of clean technology procedures and the study of new alternatives for water quality improvement. The parameters analyzed were pH, DQO, DBO, total phosphorous, total nitrogen, oils and greases, surfactants, settable solids, and suspended solids. The results showed that the effluent presents an alkaline pH, a high organic load, is rich in nitrogen and phosphorous, and presents a high concentration of surfactants. However, the implantation of clean technology procedures, by process programming and employees training, allowed a volume reduction from 8 m3/day to 6 m3/day. The load of pollutants was significantly reduced, allowing a better performance of the effluent treatment plant. The emission treatment reached, or became very near the standard. The study of new alternatives also proved that the physical-chemical treatment of coagulation/flocculation is more efficient when followed by an activated carbon adsorption treatment. The use of the TiO2 – photocatalysis process – reduced surfactants concentration in effluent. The BOD/COD relationship, ranged from 0,29 to 0,34, showed that biological degradation is possible, provided that there is microorganism acclimatizing. This fact allows the possibility for the biological treatment of the industrial effluent to be either dumped into the general sewage generated in the company or not.
3

Técnicas aplicadas ao tratamento e redução dos efluentes líquidos de uma empresa de saneantes domissanitários

Peres, Silvana Drago January 2005 (has links)
A empresa estudada está sediada em Porto Alegre, RS, Brasil, e fabrica produtos de limpeza. Os efluentes provêm das águas de lavagens dos tanques e misturadores de produção, recipientes utilizados na separação de matérias-primas e da lavagem do próprio piso da fábrica, onde ocorrem derramamentos de produtos. Foi implantada uma estação de tratamento de efluentes que opera por processos físico-químicos de coagulação/floculação e adsorção. Entretanto, observou-se que era ineficiente para atender aos parâmetros de qualidade de água exigidos pela legislação. Assim, o objeto deste estudo foi minimizar a geração de efluentes e aperfeiçoar a operação da estação de tratamento dos efluentes líquidos da empresa. A metodologia de trabalho consistiu na caracterização do efluente industrial; monitoramento do desempenho da estação de tratamento de efluentes, implantação de mudanças no processo produtivo para verificar a possibilidade de minimização da geração de efluentes bem como da carga poluidora, e estudo de alternativas de tratamento para melhorar a qualidade da água. Os parâmetros avaliados foram pH, DQO, DBO, fósforo total, nitrogênio total, óleos e graxas, surfactantes, sólidos sedimentáveis e sólidos suspensos. Os resultados demonstram que o efluente apresenta pH alcalino, uma elevada carga orgânica, é rico em nitrogênio e fósforo e possui uma alta concentração de surfactantes. Entretanto, a implantação de um sistema de produção mais limpo, através da programação prévia do processo produtivo, e aplicação de novos procedimentos durante as operações de envase, permitiu que o volume de efluentes gerados diminuísse de 8 m3/dia para 6 m3/dia. A carga de poluente na ETE baixou significativamente, resultando em maior eficiência da estação de tratamento de efluentes. Assim, foi possível atingir, exata ou aproximadamente, todos os parâmetros de emissão padrão. O estudo das alternativas de tratamento também comprovou que o tratamento físicoquímico de coagulação/floculação é mais eficiente quando seguido de um tratamento de adsorção por carvão ativado. A fotocatálise heterogênea, com aplicação de luz UV como forma de polimento ao efluente, reduz substancialmente a quantidade de matéria orgânica e surfactantes presentes no efluente. Os valores da relação DBO/DQO, para o efluente tratado, que variam de 0,29 a 0,34, demonstram a possibilidade de degradação biológica, desde que haja aclimatação ou indução dos microrganismos. Esse fato abre a possibilidade de realizar o tratamento biológico do efluente industrial, misturado ou não ao esgoto cloacal gerado na empresa. / The company studied produces cleaning reagents and is located in Porto Alegre, RS, Brazil. The effluent comes from many washing operations, including equipment and ground cleaning. A physical-chemical treatment plant was installed. It is based on coagulation/flocculation and activated carbon adsorption. However, the treatment operation did not reach the water quality emission standards established by the legislation. Thus, the aim of this work was to minimize the effluent generation and to improve the effluent treatment plant efficiency. The methodology consisted of characterization of the industrial effluent, evaluation of effluent treatment plant, implantation of clean technology procedures and the study of new alternatives for water quality improvement. The parameters analyzed were pH, DQO, DBO, total phosphorous, total nitrogen, oils and greases, surfactants, settable solids, and suspended solids. The results showed that the effluent presents an alkaline pH, a high organic load, is rich in nitrogen and phosphorous, and presents a high concentration of surfactants. However, the implantation of clean technology procedures, by process programming and employees training, allowed a volume reduction from 8 m3/day to 6 m3/day. The load of pollutants was significantly reduced, allowing a better performance of the effluent treatment plant. The emission treatment reached, or became very near the standard. The study of new alternatives also proved that the physical-chemical treatment of coagulation/flocculation is more efficient when followed by an activated carbon adsorption treatment. The use of the TiO2 – photocatalysis process – reduced surfactants concentration in effluent. The BOD/COD relationship, ranged from 0,29 to 0,34, showed that biological degradation is possible, provided that there is microorganism acclimatizing. This fact allows the possibility for the biological treatment of the industrial effluent to be either dumped into the general sewage generated in the company or not.
4

Técnicas aplicadas ao tratamento e redução dos efluentes líquidos de uma empresa de saneantes domissanitários

Peres, Silvana Drago January 2005 (has links)
A empresa estudada está sediada em Porto Alegre, RS, Brasil, e fabrica produtos de limpeza. Os efluentes provêm das águas de lavagens dos tanques e misturadores de produção, recipientes utilizados na separação de matérias-primas e da lavagem do próprio piso da fábrica, onde ocorrem derramamentos de produtos. Foi implantada uma estação de tratamento de efluentes que opera por processos físico-químicos de coagulação/floculação e adsorção. Entretanto, observou-se que era ineficiente para atender aos parâmetros de qualidade de água exigidos pela legislação. Assim, o objeto deste estudo foi minimizar a geração de efluentes e aperfeiçoar a operação da estação de tratamento dos efluentes líquidos da empresa. A metodologia de trabalho consistiu na caracterização do efluente industrial; monitoramento do desempenho da estação de tratamento de efluentes, implantação de mudanças no processo produtivo para verificar a possibilidade de minimização da geração de efluentes bem como da carga poluidora, e estudo de alternativas de tratamento para melhorar a qualidade da água. Os parâmetros avaliados foram pH, DQO, DBO, fósforo total, nitrogênio total, óleos e graxas, surfactantes, sólidos sedimentáveis e sólidos suspensos. Os resultados demonstram que o efluente apresenta pH alcalino, uma elevada carga orgânica, é rico em nitrogênio e fósforo e possui uma alta concentração de surfactantes. Entretanto, a implantação de um sistema de produção mais limpo, através da programação prévia do processo produtivo, e aplicação de novos procedimentos durante as operações de envase, permitiu que o volume de efluentes gerados diminuísse de 8 m3/dia para 6 m3/dia. A carga de poluente na ETE baixou significativamente, resultando em maior eficiência da estação de tratamento de efluentes. Assim, foi possível atingir, exata ou aproximadamente, todos os parâmetros de emissão padrão. O estudo das alternativas de tratamento também comprovou que o tratamento físicoquímico de coagulação/floculação é mais eficiente quando seguido de um tratamento de adsorção por carvão ativado. A fotocatálise heterogênea, com aplicação de luz UV como forma de polimento ao efluente, reduz substancialmente a quantidade de matéria orgânica e surfactantes presentes no efluente. Os valores da relação DBO/DQO, para o efluente tratado, que variam de 0,29 a 0,34, demonstram a possibilidade de degradação biológica, desde que haja aclimatação ou indução dos microrganismos. Esse fato abre a possibilidade de realizar o tratamento biológico do efluente industrial, misturado ou não ao esgoto cloacal gerado na empresa. / The company studied produces cleaning reagents and is located in Porto Alegre, RS, Brazil. The effluent comes from many washing operations, including equipment and ground cleaning. A physical-chemical treatment plant was installed. It is based on coagulation/flocculation and activated carbon adsorption. However, the treatment operation did not reach the water quality emission standards established by the legislation. Thus, the aim of this work was to minimize the effluent generation and to improve the effluent treatment plant efficiency. The methodology consisted of characterization of the industrial effluent, evaluation of effluent treatment plant, implantation of clean technology procedures and the study of new alternatives for water quality improvement. The parameters analyzed were pH, DQO, DBO, total phosphorous, total nitrogen, oils and greases, surfactants, settable solids, and suspended solids. The results showed that the effluent presents an alkaline pH, a high organic load, is rich in nitrogen and phosphorous, and presents a high concentration of surfactants. However, the implantation of clean technology procedures, by process programming and employees training, allowed a volume reduction from 8 m3/day to 6 m3/day. The load of pollutants was significantly reduced, allowing a better performance of the effluent treatment plant. The emission treatment reached, or became very near the standard. The study of new alternatives also proved that the physical-chemical treatment of coagulation/flocculation is more efficient when followed by an activated carbon adsorption treatment. The use of the TiO2 – photocatalysis process – reduced surfactants concentration in effluent. The BOD/COD relationship, ranged from 0,29 to 0,34, showed that biological degradation is possible, provided that there is microorganism acclimatizing. This fact allows the possibility for the biological treatment of the industrial effluent to be either dumped into the general sewage generated in the company or not.
5

Isolamento e seleção de microrganismos para remediação de efluente oleoso da indústria metal-mecânica / Isolation and selection of microorganisms for the oily effluent remediation of the metalworking industry

Queissada, Daniel Delgado 15 September 2009 (has links)
A indústria metal-mecânica é responsável pela síntese de um dos efluentes oleosos mais complexos e difíceis de tratamento e reuso. Esses efluentes são constituídos, entre outros poluentes, por fluidos de corte, que servem para refrigerar e lubrificar peças metálicas no sistema de usinagem. Quando esses efluentes são tratados biologicamente é importante que se faça isso com microrganismos autóctones do mesmo, pois o uso desses microrganismos (bioaumentação) tende a ser mais eficaz, uma vez que os mesmos já estão adaptados aos poluentes nele existentes. Com este propósito, o presente trabalho teve como objetivo principal o isolamento e seleção de microrganismos para remediação de um efluente metalmecânico através de tratamentos unitários em bioreator do tipo air-lift e por sistema oxidativo UV/H2O2, além do tratamento integrado com ambos os processos. No tratamento biológico foram utilizados os microrganismos autóctones do efluente estudado, além do uso do fungo Aspergillus niger como microrganismo de referência. A caracterização do efluente bruto mostrou que, em decorrência dos parâmetros determinados como, 1495 mg Pt/L de cor, DQO de 9147 mg/L, 53 mg/L de fenóis-totais, 15666 mg/L de ST, 2,5 mgO2/L de OD, 887 mg/L de O&G e fator de toxicidade crônica de 1667, o mesmo possui um alto potencial poluidor. Foram isolados, da amostra do efluente, seis possíveis tipos de fungos filamentosos. Dentre os quais, Epicoccum nigrum e Cladosporium sp, foram os que se mostraram mais eficazes para a realização do tratamento do efluente em reator do tipo air-lift. No biotratamento em reator airlift o fungo Epicoccum nigrum se mostrou mais eficaz na maioria das reduções dos parâmetros determinados (27% da DQO, 62% de fenóis-totais, 94% do H2O2, 44% da Cond. E e de 43% de O&G), já Cladosporium sp foi mais apto na redução de cor (87%). O tratamento oxidativo com sistema UV/H2O2, obteve reduções mais intensas, do que o tratamento biológico, em relação aos parâmetros de DQO (34%), H2O2 (98%) e no aumento de OD (705%) da amostra do efluente. Entretanto, foi menos eficaz nas reduções de cor (74%), fenóis-totais (24%), ST (15%) e Cond.E (34%) e atingiu um desempenho semelhante, em relação ao tratamento biológico, na redução de O&G (45%). Já o tratamento integrado do efluente por sistema UV/H2O2 seguido de tratamento biológico, propiciou uma intensificação nas reduções de todos os parâmetros avaliados pós-tratamento. Indicando assim que, o tratamento fotoquímico, antecipado ao tratamento biológico, aumentou a biodegradabilidade da amostra do efluente, facilitando desta forma a biorremediação do mesmo em reator air-lift. Entre os três sistemas de tratamento estudados (biológico, UV/H2O2 e UV/H2O2 - biológico), o processo integrado utilizando o sistema fotoquímico UV/H2O2 seguido do tratamento biológico com o fungo E. nigrum foi o mais eficaz para o efluente estudado. / The metalworking industry is responsible for one of the most complex and difficult to reuse and handling, oily effluents synthesis. These effluents are made by cutting fluids which provide refrigeration and purification of metallic pieces in the machining system. When these effluents are biologically treated is important to do this with autochthonous microorganisms, therefore the use of these microorganisms (bioaugmentation) tends to be more efficient because they are already adapted to the existing pollutants. The aim of this work was the isolation and selection of remediation microorganisms of metalworking effluent through unit processes (air-lift bioreactor and UV/H2O2 system) and also through their integration. In the biological treatment were used the autochthonous microorganisms from metalworking effluent beyond the use of Aspergillus niger as reference microorganism. The original effluent characterization presented a great pollutant potential. The value of color of the effluent was 1495 mg Pt/L, COD was 9147 mgO2/L, total phenols was 53 mg/L, total solids (TS) was 15666 mg/L, dissolved oxygen (DO) was 2.5 mgO2/L, oil and grease was 887 mg/L and chronic toxicity factor was 1667. Six possible types of filamentous fungi were isolated from the effluent sample. Among them, Epicoccum nigrum and Cladosporium sp were the most efficient in the air-lift reactor treatment. In the air-lift reactor biotreatment the fungus Epicoccum nigrum was the most efficient in the majority of the parameters reductions (of 27% COD, 62% total phenols, 94% H2O2, 44% electrical conductivity and 43% oil and grease) and Cladosporium sp was more efficient in the color reduction (87%). The oxidative treatment system (UV/H2O2) was more efficient than the biological treatment in the reductions of COD (34%) and H2O2 (98%) and increase of the DO (705%). However was less efficient in the reductions of color (74%), total phenols (24%), TS (15%) and electrical conductivity (34%) and reached a similar performance in the oil and grease reduction (45%). On the other hand, the integrated effluent treatment by UV/H2O2 system followed by biological treatment provided an intensification of reductions in all of the evaluated parameters after treatment. Indicating that the photochemistry treatment anticipated to the biological treatment increased biodegradability of the effluent sample, facilitating bioremediation in reactor air-lift. Among the three treatment systems evaluated (biological, UV/H2O2 and UV/H2O2 - biological), the integrated processes utilizing the photochemistry system UV/H2O2 followed by the biological treatment (E. nigrum) was the most efficient.
6

Avaliação do pré-tratamento do efluente de indústria química com adição de linhagens microbianas especializadas na degradação de compostos tóxicos / Evaluation of the industrial wastewater pretreatment adding microbial strains specialized in toxic compounds degradation

Machado, Flavio Silva 28 July 2009 (has links)
As indústrias químicas são consideradas como o segmento industrial que gera os efluentes mais perigosos ao meio ambiente. Em virtude das concentrações expressivas de poluentes, tanto orgânicos quanto inorgânicos, os efluentes dessas indústrias podem interferir na atividade da biomassa de estações de tratamento de efluentes (E.T.E.), diminuindo sua eficiência e gerando efluentes tratados, porém em desacordo com a legislação pertinente. Para prevenir tais efeitos, o recebimento de efluentes industriais em E.T.E.s pode ser precedido por pré-tratamento, dentre os quais, o biológico, otimizado pela adição de microrganismos com capacidade de degradar poluentes. Foram isolados microrganismos com capacidade de degradar os compostos identificados como responsáveis pela toxicidade do efluente final da E.T.E.: benzeno, clorofórmio, 1,2-dicloroetano, pentaclorofenol, tricloroeteno, tolueno e p-xileno. Foram realizados testes de bioaumentação para pré tratar o efluente industrial, que foram avaliados através de ensaios físico-químicos e de toxicidade aguda para Vibrio fischeri e Daphnia similis. Os resultados obtidos demonstraram que o pré tratamento reduziu a toxicidade do efluente final da estação de tratamento. / Chemical industries are considered the industrial sector that generates the most dangerous effluents to the environment. Due to the high pollutant concentration, either organics or inorganics, the chemical industries effluents may interferer in the biomass activity in wastewater treatment plants (WWTP), what may reduce its efficiency and generate treated effluents in disagreement to the concerned law. In order to prevent such effects, the industrial effluents disposal in WWTPs can be preceded by biological pretreatment, which can be optimized by adding microorganisms capable of pollutants degradation. Microorganism strains that are able to degrade the compounds identified as the responsible for toxicity levels in the WWTP final effluent: benzene, chloroform, 1,2-dichloroethane, pentachlorophenol, trichloroethene, tolune and p-xylene were isolated. Bioaugmentation tests aiming the chemical effluent pretreatment were performed and they were evaluated through physical-chemical analysis and acute toxicity tests for Vibrio fischeri and Daphnia similis. The results showed that the industrial effluent pretreatment reduced the toxicity levels in the WWTP final effluent.
7

Confiabilidade operacional de Estação de Tratamento de Efluentes Industriais (ETEI) de refinaria de petróleo: estudo de caso. / Industrial Wastewater Treatment Plant (WTP) operational reliability of petroleum refinery: case of study.

Shyrlene Lima de Aquino Oliveira 04 April 2014 (has links)
O projeto de Estações de Tratamento de Efluentes Industriais (ETEIs) deve objetivar um desempenho médio, o qual não pode ser ultrapassado certo número de vezes durante seu tempo operacional. Este trabalho propõe a aplicação da metodologia conhecida como Coeficiente de Confiabilidade (CDC) para quantificação da confiabilidade das etapas de tratamento físico (Separação Águaóleo SAO e flotação) e biológico (lodos ativados com aeração prolongada), considerando efluente oleoso proveniente de refino de petróleo. Tal metodologia, entretanto, não possibilita a identificação das prováveis causas do baixo desempenho na tratabilidade. Por isso também é proposta a aplicação da ferramenta de gestão riscos conhecida como FMECA (Failure Modes, Effects and Criticality Analysis), que permite a quantificação das observações qualitativas de campo, tornando os valores comparáveis para definir a hierarquização dos riscos e criticidade das etapas de tratamento estudadas. A etapa biológica para o parâmetro NH3 apresentou a maior confiabilidade, ainda que a análise de risco tenha apontado esta etapa como mais crítica. Ou seja, um sistema confiável não necessariamente apresenta menor criticidade, pois uma má gestão implicará em possíveis infrações às metas pré-fixadas ou à própria legislação ambiental.
8

Metais pesados em água, sedimentos e peixes no rio Maranguapinho, Região Metropolitana de Fortaleza, Ceará / Heavy metals in water, sediments and fishes in the Maranguapinho river, Fortaleza Metropolitan Region, Ceara

Correa, Jean Michel January 2014 (has links)
CORREA, Jean Michel. Metais pesados em água, sedimentos e peixes no rio Maranguapinho, Região Metropolitana de Fortaleza, Ceará. 2014. 139 f. Tese (Doutorado em geologia)- Universidade Federal do Ceará, Fortaleza-CE, 2014. / Submitted by Elineudson Ribeiro (elineudsonr@gmail.com) on 2016-06-07T19:06:21Z No. of bitstreams: 1 2014_tese_jmcorrea.pdf: 5358041 bytes, checksum: 9f48cb9859e12cefb43009585d9fc136 (MD5) / Approved for entry into archive by José Jairo Viana de Sousa (jairo@ufc.br) on 2016-06-07T23:32:51Z (GMT) No. of bitstreams: 1 2014_tese_jmcorrea.pdf: 5358041 bytes, checksum: 9f48cb9859e12cefb43009585d9fc136 (MD5) / Approved for entry into archive by José Jairo Viana de Sousa (jairo@ufc.br) on 2016-06-07T23:35:49Z (GMT) No. of bitstreams: 1 2014_tese_jmcorrea.pdf: 5358041 bytes, checksum: 9f48cb9859e12cefb43009585d9fc136 (MD5) / Made available in DSpace on 2016-06-07T23:35:49Z (GMT). No. of bitstreams: 1 2014_tese_jmcorrea.pdf: 5358041 bytes, checksum: 9f48cb9859e12cefb43009585d9fc136 (MD5) Previous issue date: 2014 / Aquatic ecosystems are considered receivers of contaminants released into the environment, being susceptible the actions of domestic and industrial effluents which are released directly into this ecosystem. Among the environmental contaminants are heavy metals which are highly resistant to degradation. They can occur in different chemical forms in nature and therefore may increase or reduce its toxic characteristics toward several organisms and their biological characteristics, according to their concentration in the ecosystem. The Maranguapinho river presents environmental problems, such as pollution, deforestation of its margins, among others. The river bed is silted up due to the replacement of riparian vegetation and receives several channels in the region, clandestine pipes of domestic sewages. A two-year study was carried out in three reaches located in this river: RMA-A (high basin), RMA-B (middle basin) and RMA-C (low basin). A total of 93 fishes were collected, distributed in four orders, seven families, nine genera and 11 species. The species richness was highest in RMA-B, with five species. Although above the maximum allowed value, the concentrations of Al, Fe and Mn found in the water were not considered contaminants, indicating that these elements are the result of lithological composition of the region. The geoaccumulation index indicated that all the sediment samples of Maranguapinho are classified into Class 1 due to the small variation in the intensity of pollution, revealing that the elements are natural constituents of the basin. The sample size used was 21 individuals for further toxicological representation of fishes captured. Hypostomus jaguribensis and Loricariichthys nudirostris species showed the highest amounts of the metals studied (Al = 44,34 ppm, Fe = 460,15 ppm and Sr = 1,38 ppm), trending to accumulate high amounts of metals in the body and can be considered good bioindicators. The ANOVA revealed a statistically significant difference between the concentrations of Cd and Zn in the viscera of fish and the maximum values allowed by the law, showing that these elements can cause contamination risks to fish and humans and allowed the distinction of marginal influences between the average of Fe and Mn in the viscera of fish and water stations, being the water the factor of entry of the elements in the animal organism. The Maranguapinho river is a natural environment potentially fragile. Several kinds of anthropogenic interferences, such as discharge of effluents, contributes for the its environmental degradation. / Os ecossistemas aquáticos são considerados receptores de contaminantes liberados no ambiente, estando susceptíveis as ações de efluentes domésticos e industriais que são lançados sem tratamento diretamente neste ecossistema. Dentre os contaminantes ambientais, encontram-se os metais pesados, que são altamente resistentes a degradação. Metais pesados podem ocorrer sob diferentes formas químicas na natureza e conseqüentemente podem aumentar ou reduzir suas características tóxicas para com os diversos organismos e suas características biológicas, de acordo com suas concentrações no ecossistema. O rio Maranguapinho apresenta problemas ambientais, a exemplo da poluição, desmatamentos de suas margens, dentre outros. O leito do rio encontra-se praticamente todo assoreado em decorrência da substituição da mata ciliar e recebe água de diversos canais da região, de tubulações clandestinas de efluentes domésticos. Nesse contexto, um estudo foi realizado nos anos de 2012 e 2013 em três estações de amostragem situadas nesse rio: RMA-A, situada no alto curso, RMA-B, situada no médio curso e RMA-C, situada no baixo curso. Foram coletados 93 peixes, distribuídos em quatro ordens, sete famílias, nove gêneros e 11 espécies. A riqueza de espécies foi maior no RMA-B, com cinco espécies. As concentrações de Al, Fe e Mn encontradas na água, embora acima do valor máximo permitido, não foram consideradas contaminantes, indicando que esses elementos são resultantes da composição litológica da região. O índice de geoacumulação indicou que todas as amostras de sedimentos do rio Maranguapinho estão enquadrados na classe 1 em virtude da pouca variação apresentada na intensidade de poluição, revelando que os elementos encontrados são constituintes naturais da bacia. O tamanho da amostra utilizada foi de 21 exemplares para uma maior representatividade toxicológica da ictiofauna capturada. As espécies detritívoras Hypostomus jaguribensis e Loricariichthys nudirostris apresentaram as maiores quantidades dos metais estudados (Al = 44,34 ppm, Fe = 460,15 ppm e Sr = 1,38 ppm), possuindo uma maior tendência a acumular em seu organismo elevadas quantidades de metais e podendo ser considerados bons indicadores da qualidade ambiental. A ANOVA revelou diferença estatisticamente significante entre as concentrações de Cd e Zn nas vísceras dos peixes e os valores máximos permitidos na legislação, mostrando que esses elementos podem causar sérios riscos de contaminação aos peixes e humanos e também permitiu distinguir influências marginais entre as médias de Fe e Mn nas vísceras dos peixes e na água das estações, sendo a água o fator de ingresso dos elementos no organismo animal. A bacia do rio Maranguapinho é um ambiente natural potencialmente frágil. Os vários tipos de interferências antropogênicas, em especial a descarga de efluentes, contribuíram de forma marcante para a sua degradação ambiental.
9

Aplicação de crômio via água residuária de curtume em solo cultivado com capim mombaça (Panicum Maximum CV.) / Application of chromium via tannery wastewater in soil cultivated with grass mombaça (Panicum Maximum CV.)

Oliveira, Pedro Rodrigues de 28 July 2010 (has links)
Made available in DSpace on 2015-03-26T13:23:33Z (GMT). No. of bitstreams: 1 texto completo.pdf: 5548004 bytes, checksum: 0e2b26d42170cde6367459cb6364be5e (MD5) Previous issue date: 2010-07-28 / The pressure on natural resources, especially water, has required the development of alternative forms of treatment of effluent, with the provision in the soil through fertigation has been considered quite feasible. With fertigation, allows to use the nutrients available in wastewater, providing an increase in agricultural productivity, and an important tool for environmental control, since, even if treated conventionally, the effluents discharged into water bodies bring problems to the aquatic ecosystems, and the background to humans. The application of wastewater in agriculture requires, however, technical knowledge about the characteristics of the wastewater, of plants grown and soil, also the use must be planned, controlled and well managed so that avoidance of groundwater contamination and adverse changes in properties and physical and chemical characteristics of soil. Accordingly, the present study aimed to evaluate the effects of irrigation with tannery wastewater (ARC) in soil and the grass Panicum maximum (Panicum maximum cv. Mombasa). To conduct the work, was set up an experiment in a greenhouse where grass was planted in pots in a randomized design scheme, consisting of six treatments and four replications. In T1, the soil was irrigated with clean water and complete fertilization (NPK + lime) in treatments T2, T3, T4, T5 and T6 soil received complete fertilizer (NPK + lime) and was fertilized with 44 of ARC on slides, 103, 147, 294 and 441 mm, respectively, applied using a watering guide. Three cuts were carried out on the grass to quantify the productivity of fresh and dry and to quantify the levels of nutrients and chromium in the leaves. The macronutrient and metal chromium in soil were quantified at the beginning and end of the experiment. The increasing application rates of ARC promoted increased soil electrical conductivity when compared to what was obtained in the control treatment, and slight increase in pH and concentrations of available P and exchangeable K. No changes in concentration of organic matter and Cr in the soil. There was an increase in grass productivity with increasing applied dose of ARC. Analysis of leaves showed increased levels of nitrogen and, although it was observed high coefficient of variation of data, little change in the concentration of chromium in the shoots. / A pressão sobre os recursos naturais, em especial os recursos hídricos, tem exigido o desenvolvimento de formas alternativas de tratamento dos efluentes, sendo que a disposição no solo por intermédio da fertirrigação tem sido considerada bastante viável. Com a fertirrigação, possibilita-se o aproveitamento dos nutrientes existentes nas águas residuárias, proporcionando incremento na produtividade agrícola, sendo uma ferramenta de controle ambiental importante, uma vez que, mesmo tratados de forma convencional, os efluentes lançados em corpos hídricos trazem problemas para os ecossistemas aquáticos e, em segundo plano, para os seres humanos. A aplicação de águas residuárias na agricultura requer, no entanto, conhecimentos técnicos acerca das características da água residuária, dos vegetais cultivados e do solo, também o uso deve ser planejado, controlado e bem manejado a fim de que sejam evitadas a contaminação das águas subterrâneas e alterações prejudiciais nas propriedades e características físicas e químicas do solo. Nesse sentido, no presente trabalho, objetivou-se avaliar os efeitos da fertirrigação com água residuária de curtume (ARC) no solo e no capim mombaça (Panicum maximum cv. Mombaça). Para a condução dos trabalhos, montou-se um experimento em casa de vegetação, onde o capim foi plantado em vasos, em esquema de delineamento inteiramente casualizado, constituído de seis tratamentos e quatro repetições. No tratamento T1, o solo recebeu irrigação com água limpa e adubação completa (NPK + calagem), nos tratamentos T2, T3, T4, T5 e T6 o solo recebeu adubação completa (NPK + calagem) e foi fertirrigado com ARC em lâminas de 44, 103, 147, 294 e 441 mm, respectivamente, aplicada utilizando-se um regador manual. Foram realizados 3 cortes no capim para quantificação da produtividade de matéria verde e seca e para quantificação dos teores de nutrientes e crômio nas folhas. Os teores de macronutrientes e do metal crômio no solo foram quantificados no início e final do experimento. As taxas de aplicação crescentes da ARC proporcionaram aumento na condutividade elétrica do solo, quando comparado ao que foi obtido no tratamento testemunha, além de pequeno incremento no pH e nas concentrações de Pdisponível e Kdisponível. Não ocorreram alterações na concentração de matéria orgânica e Crdisponível no solo. A análise das folhas indicou aumento nos teores de nitrogênio e, apesar de ter sido observado alto coeficiente de variação dos dados, ocorreu pequena alteração na concentração de crômio na parte aérea das plantas.
10

Confiabilidade operacional de Estação de Tratamento de Efluentes Industriais (ETEI) de refinaria de petróleo: estudo de caso. / Industrial Wastewater Treatment Plant (WTP) operational reliability of petroleum refinery: case of study.

Shyrlene Lima de Aquino Oliveira 04 April 2014 (has links)
O projeto de Estações de Tratamento de Efluentes Industriais (ETEIs) deve objetivar um desempenho médio, o qual não pode ser ultrapassado certo número de vezes durante seu tempo operacional. Este trabalho propõe a aplicação da metodologia conhecida como Coeficiente de Confiabilidade (CDC) para quantificação da confiabilidade das etapas de tratamento físico (Separação Águaóleo SAO e flotação) e biológico (lodos ativados com aeração prolongada), considerando efluente oleoso proveniente de refino de petróleo. Tal metodologia, entretanto, não possibilita a identificação das prováveis causas do baixo desempenho na tratabilidade. Por isso também é proposta a aplicação da ferramenta de gestão riscos conhecida como FMECA (Failure Modes, Effects and Criticality Analysis), que permite a quantificação das observações qualitativas de campo, tornando os valores comparáveis para definir a hierarquização dos riscos e criticidade das etapas de tratamento estudadas. A etapa biológica para o parâmetro NH3 apresentou a maior confiabilidade, ainda que a análise de risco tenha apontado esta etapa como mais crítica. Ou seja, um sistema confiável não necessariamente apresenta menor criticidade, pois uma má gestão implicará em possíveis infrações às metas pré-fixadas ou à própria legislação ambiental.

Page generated in 0.0564 seconds