• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 13
  • Tagged with
  • 13
  • 13
  • 13
  • 7
  • 6
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Parâmetros projetuais para implantação de sanitários secos desidratadores com desvio de urina (SSDU)

Demenighi, Alexandra Lima 05 December 2013 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2013 / Made available in DSpace on 2013-12-05T22:13:08Z (GMT). No. of bitstreams: 1 316852.pdf: 3737010 bytes, checksum: b59b59baa024033818957a069d2990b6 (MD5) / Sistemas convencionais de coleta e tratamento de esgotos além deu tilizarem grande quantidade de água para transportar os dejetos apresentam níveis de eficiência técnica e econômica nem semprecompatíveis com o contexto em que são implantados. Diante da escassezdos recursos naturais, principalmente da água potável, ressalta-se aimportância de que a intervenção humana no ciclo hidrológico se dê deforma mais sustentável.O sistema de saneamento seco não utiliza água para o seufuncionamento. As fezes, pela possibilidade de conter organismospatogênicos são coletadas e armazenadas para posterior tratamento etransformadas em um produto seguro para ser devolvido ao solo. A separação da urina, nestes sistemas, apóia-se em vários estudos realizados que demonstram sua aplicação como fertilizante por ser livrede organismos patogênicos. Estes fundamentos estão aplicados nosistema de saneamento proposto, denominado: Sanitário Seco Desidratador com Desvio da Urina (derivado da sigla em inglês - UDDT- Urine Diversion Dehydration Toilets), que considera os ?dejetos?recursos, constituindo valiosos fertilizantes para o solo, fechando o ciclode nutrientes e eliminando qualquer geração de resíduos.Neste trabalho, realizou-se estudos de caso em locais que utilizaram este sistema como opção de saneamento, com a intenção de identificar os parâmetros projetuais para sua implantação.Como resultado, se definiu uma tipologia de Sanitário Seco Desidratador com Desvio de Urina dimensionado pelo número de ocupantes adaptado para as condições brasileiras, especificando os componentes de projeto do sistema de coleta e armazenamento das fezes e urina. A operação do sistema e as recomendações para o gerenciamento e tratamento das fezes e urina humanas também foram alvo da pesquisa afim de promover o uso da tecnologia em condições de salubridade a favor dos recursos naturais. <br> / Conventional systems for collecting and treating sewage besides using large amounts of water to carry the waste present levels of technical and economic efficiency is not always compatible with the context in which they are deployed. Given the scarcity of natural resources, especially drinking water, it emphasizes the importance of human intervention in the water cycle takes place in a more sustainable way. The sanitation system does not use water for dry operation. Faeces, by the possibility of containing pathogenic organisms are collected and stored for later treatment and transformed into a safe product to be returned to the soil. The separation of the urine, these systems relies on several studies that demonstrate its application as a fertilizer to be free of pathogenic organisms. These fundamentals are applied in the proposed sanitation system, called: Sanitary Dry Dehydrator with Offset Urine (derived from the acronym - UDDT - Urine Diversion Dehydration Toilets), which considers the "waste" resources, providing valuable fertilizer to the soil, closing the nutrient cycle and eliminating any waste. This work was carried analyzing out case studies in places that used this system as an option for sanitation, with the intention of identifying the parameters projectuais for its implementation. As a result, we defined a typology of Sanitary Dry Dehydrator with Urine diverting scaled by the number of occupants adapted to Brazilian conditions specifying the components of the system design for collection and storage of urine and faeces. The operation of the system and recommendations for the management and treatment of human feces and urine were also targeted research to promote the use of technology in health conditions in favor of natural resources.
2

Estudo da conservação de agua em edificios localizados no campus da Universidade Estadual de Campinas

Nunes, Solange da Silva 16 August 2000 (has links)
Orientador: Marina Sangoi de Oliveira Ilha / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Engenharia Civil / Made available in DSpace on 2018-07-27T04:48:27Z (GMT). No. of bitstreams: 1 Nunes_SolangedaSilva_M.pdf: 4336443 bytes, checksum: 80ccf564a373ce24901dea9cfec73454 (MD5) Previous issue date: 2000 / Resumo: A manutenção dos sistemas prediais em edificios institucionais é centralizada e composta por um pequeno número de pessoas. Nessa tipologia de edificio, os usuários não estão normalmente preocupados com o consumo de água, uma vez que eles não são diretamente responsáveis pelo pagamento desse insumo. Isto provoca uma situação .generalizada de vazamentos e desperdícios de água. O presente trabalho consiste na análise dos aspectos relacionados com a conservação de á~a em dezenove edificios localizados na Universidade Estadual de Campinas - UNICAMP, a qual possui uma população diária de 30.000 pessoas e cerca de 250 edificios. O estudo contemplou o monitoramento do consumo de á.gua,bem como, a detecção e reparos de vazamentos, substituição de torneiras convencionais de mictórios e lavatórios por torneiras economizadoras e aplicação de questionários para avaliar os hábitos e opinião dos usuários no que se refere ao desempenho e aceitação dos componentes economizadores. A metodolo.giautilizada para atin.giros objetivos estabelecidos foi satisfatória, podendo ser empregada em grande número de edificios com facilidade. Os resultados indicaram uma redução significativa do consumo de á~a em todas as unidades estudadas, sendo a maior porcentagem advinda do conserto dos vazamentos... Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: Usually, the maintenance service in Institutional building is centralized and has a small staff In this setting, users are not worried about water consumption since they are not directly affected by the consumption costs. These aspects cause a generalized situation of leakage and water losses. This study is concemed with the analysis of some aspects related to water conservation in nineteen buildings located in the Campus of the State University oí Campinas, Sao Paulo, which has a daily population of 30000 users and almost 250 buildings. The research had contemplated the plumbing fixtures survey in all buildings, waste water detection and repair, water consumption remote monitoring and replacement of traditional urinal and lavatory faucets by saver ones. The results indicated a decrease of 10 to 87.5 percent in the monthly water consumption. The acceptance percentage was elevated, being 88% for the lavatory faucets and 95% for the urinals faucets... Note: The complete abstract is available with the full electronic digital thesis or dissertations / Mestrado / Edificações / Mestre em Engenharia Civil
3

Avaliação do desempenho funcional de bacias sanitarias de volume de descarga reduzido com relação a remoção e transporte de solidos

Oliveira Junior, Osvaldo Barbosa de 22 February 2002 (has links)
Orientador: Marina Sangoi de Oliveira Ilha / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T03:52:29Z (GMT). No. of bitstreams: 1 OliveiraJunior_OsvaldoBarbosade_M.pdf: 11738224 bytes, checksum: 8dbea93f82b3a01d952b8310349654ec (MD5) Previous issue date: 2002 / Resumo: Para a efetiva implantação de bacias sanitárias de volume de descarga reduzido, torna-se necessário estabelecer testes laboratoriais que simulem, o mais próximo possível, as condições reais de funcionamento desses aparelhos, avaliando não somente o componente propriamente dito, mas também o seu desempenho no que se refere à capacidade de transporte em ramais longos, considerando-se as características das bacias sanitárias brasileiras. Inserido neste contexto, foi desenvolvido o presente trabalho, que consiste na análise dos testes atualmente realizados e em estudo relativos ao assunto, buscando uma correlação e comparação entre os testes existentes, variando-se as mídias e buscando a melhor combinação destas com o conjunto de ensaios, de forma a possibilitar a avaliação do desempenho de bacias sanitárias de volume de descarga reduzido, com relação à remoção e transporte de sólidos. Foi desenvolvido também um estudo de campo, para a verificação do comportamento das bacias sanitárias de volume de descarga reduzido frente às condições reais de funcionamento. Como resultados principais, destacam-se o desenvolvimento de uma metodologia de ensaio laboratorial e a comprovação da redução no consumo de água nas residências pesquisadas, sem a constatação de problemas sérios no desempenho das bacias sanitárias em campo, além da definição de uma carga de ensaio com as novas mídias subsidiada por simulações em laboratório e com os resultados do campo / Abstract: For the effective utilization of ultra low flush toilets, becomes necessary to establish laboratories tests that simulate, as close as possible, the real conditions of operation of those apparels, evaluating not on1y the component properly says, but also its acting in what refers to the transport capacity in long drains, being considered the characteristics of the Brazilian toilets. Inserted in this context, it is that intended the development of this work, that consists the ana1ysis of tests accomplished and in study relative to the subject, with relation to the waste removal and transport capability, looking for a correlation and comparison among the existent tests, being varied the midias and looking for the best combination of these with the laboratories tests, in way to facilitate the evaluation of the acting of ultra low flush toilets. It intended also developed the field study, for the verification of the behavior of the ultra low flush toilets front to the real conditions of operation. As main results, stand out the development of a methodology of laboratorial research and the confirmation of the reduction in the consumption of water in the researched residences, without the verification of serious problems when using the sanitary basins in field, besides the definition of a load with the new midias subsidized by simulations in laboratory and with the results by field / Mestrado / Edificações / Mestre em Engenharia Civil
4

Avaliação durante operação dos sistemas prediais hidraulicos e sanitarios em edificios escolares

Araujo, Leticia Santos Machado de 02 October 2004 (has links)
Orientador : Marina Sangoi de Oliveira Ilha / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T22:17:29Z (GMT). No. of bitstreams: 1 Araujo_LeticiaSantosMachadode_M.pdf: 8736761 bytes, checksum: e004cdeaaf425e1a5c5e470b74fd64b6 (MD5) Previous issue date: 2004 / Resumo: Os sistemas prediais hidráulicos e sanitários devem estar aptos a serem operados durante toda a vida útil da edificação, pois são responsáveis por disponibilizarem diversos insumos, tais como água e energia, aos usuários. A qualidade dos mesmos implica não só no adequado desempenho, atendendo às necessidades dos usuários, mas também na racionalização do uso dos insumos, evitando perdas e desperdícios, minimizando, assim, os impactos da ação antrópica no meio ambiente. Inserido neste contexto, este trabalho consiste em uma pesquisa de avaliação dos sistemas prediais hidráulicos e sanitários durante a operação, em uma amostra de 83 escolas da rede municipal de Campinas. São apresentados os resultados do levantamento cadastral e de patologias e da aplicação de questionários aos usuários de sete tipologias de edifícios escolares, além de alternativas de ações, tendo em vista a melhoria da qualidade dos sistemas prediais hidráulicos e sanitários nessa tipologia de edificação / Abstract: Plumbing systems must be able to be used during the course of the life of the building, since they are responsible by many resources. Quality of building systems implies not only adequate performance, in order to respond to the user's requirements, but also the rational resources use, avoiding wastage and, thus, reducing the impacts on the environment. Taking this perspective into account, this work presents an evaluation during operation of the cold water, hot water, rain water, drainage and fire protection systems of 83 public schools located in Campinas, Sao Paulo. Results of plumbing fixtures survey and questionnaire application in seven types of schools are presented, besides recommendations for implementation of an action plan to improve the performance of the plumbing systems in this type of building / Mestrado / Edificações / Mestre em Engenharia Civil
5

Fatores associados aos parâmetros ajustados na equação de cinética de primeira ordem modificada utilizada em sistemas alagados construídos / Factors associated whit the parameters set on the modified first order of kinetic equation used in constructed wetlands

Costa, Renan de Almeida 12 February 2016 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2016-07-08T17:19:31Z No. of bitstreams: 1 texto completo.pdf: 3542099 bytes, checksum: 22150f7209aa6581ebda209f34507ebd (MD5) / Made available in DSpace on 2016-07-08T17:19:31Z (GMT). No. of bitstreams: 1 texto completo.pdf: 3542099 bytes, checksum: 22150f7209aa6581ebda209f34507ebd (MD5) Previous issue date: 2016-02-12 / O presente trabalho teve por objetivo avaliar a relação entre o parâmetro de potência do tempo de detenção hidráulica (n), do modelo matemático de cinética de primeira ordem modificado por Brasil et al. (2007), com o número de dispersão hidráulica (d) e também com o comportamento da degradabilidade do material orgânico, obtida a partir da relação DQO/DBO, ao longo do comprimento de sistemas alagados construídos de escoamento horizontal subsuperficial (SAC-EHSS). Para isto, foram utilizados SACs-EHSS não plantados, de iguais volumes, mas com configurações geométricas distintas, denominados SAC1, SAC2 e SAC3, os quais possuíam relação comprimento largura (L/B) crescente, respectivamente de 1,0, 4,0 e 7,3. Todos os SACs-EHSS foram preenchidos com brita # 0 e receberam esgoto sanitário (ES). Foram realizados ensaios com traçador em dois momentos, antes e após os SACs-EHSS receberem ES, buscando-se, com isso, avaliar as diferenças no comportamento hidrodinâmico dos sistemas, após a passagem de ES, bem como determinar o parâmetro número de dispersão d. No período compreendido entre as execuções dos ensaios com traçador, os sistemas foram monitorados por 90 dias, sendo avaliadas as variáveis pH, condutividade elétrica (CE), demanda química de oxigênio (DQO) e demanda bioquímica de oxigênio (DBO), ambas na fração bruta e solúvel no ES em tratamento em pontos afluente, efluente e intermediários. Os dados experimentais de CE, DQO e DBO foram avaliados na forma bruta, sem que fossem feitas correções quanto às perdas hídricas por evaporação, e também após essa correção, para que fosse avaliado o efeito dessas perdas nas variáveis. Para análise estatística, foi utilizada ANOVA a 5% de significância no caso em que os dados apresentavam distribuição paramétrica e Kruskal-Wallis a 5%, quando os dados eram não paramétricos. Os ensaios hidrodinâmicos mostraram comportamento disperso para os três SACs-EHSS, sendo os valores encontrados para d próximos entre si, indicando que as diferentes configurações não proporcionaram mudanças consideráveis nas condições hidrodinâmicas do sistema. Além disso, foi verificada redução dos valores de d do primeiro ensaio para o segundo. Não foram constatadas diferenças significativas quando comparadas as médias de eficiência de remoção entre os SACs para cada situação e nem entre os valores não corrigidos e corrigidos considerando-se as perdas por evaporação. Os dados experimentais de DQO e DBO nas formas bruta e solúvel foram ajustados ao modelo proposto por Brasil et al. (2007), explicitando-se, assim, os valores do parâmetro n das equações. Outros modelos cinéticos foram também ajustados aos dados de DQO e DBO na forma bruta e solúvel, corrigidos e não corrigidos, sendo observado que o modelo convencional de primeira ordem apresentou não só os menores valores para o coeficiente de decaimento de matéria orgânica k0, mas também os menores coeficientes de determinação (R²). Observou- se, em todos os casos, relação inversa entre os parâmetros d e n, sendo as maiores relações verificadas para n obtido a partir do ajuste aos dados de DBO, em todas as formas, e a menor correlação para os valores de n ajustados aos dados de DQO solúvel. Foi observada inexistência de associação entre os valores de n e TDH nos sistemas, havendo, no entanto, elevada correlação entre n e a taxa de decaimento da matéria orgânica obtida no trecho relativo ao primeiro quinto do comprimento dos SACs-EHSS, indicando que a variável se reduz, à medida que há aumento na degradação relativa do efluente. / This study aimed to evaluate the relation between the exponent parameter of hydraulic retention time (n), from the first-order kinetics mathematical model modified by Brazil et al. (2007), with hydraulic dispersion number (d) and also with the organic material’s degradability behavior along the length of the constructed wetlands of horizontal subsurface flow (CW-HSSF), given by the ratio COD /BOD. For this, non-planted CW-HSSF were used, with equal volumes, but with different geometric configurations, called CD1, CD2 and CD3, which had increasing relative length breadth (W/B) respectively by 1.0, 4.0 and 7.3. All CW-HSSF were filled with gravel # 0 and received sewage (S). Dye tracer tests were performed in two stages, before and after CW-HSSF receive S, seeking to evaluate the differences in the systems’ hydrodynamic behavior, after S’s passage, as well as to determine the parameter dispersion number d. In the period between the tests with tracer, the system was monitored for 90 days and were evaluated the variables pH, electrical conductivity (EC), chemical oxygen demand (COD) and biochemical oxygen demand (BOD), both raw and soluble fractions in ES treatment in tributary, effluent and intermediates points. The experimental EC, COD and BOD data were evaluated in gross form, without corrections to be made on the water loss due to evaporation, and also after that correction, in order to evaluate the water deficit effect on variables. Other hydrodynamic tests showed scattered results for the three SACs-EHSS, and the values found for d were close among each other, indicating that the different settings did not provide substantial changes regarding to the hydrodynamic flow. Furthermore, a reduction behavior in d was identified from the first test values to the second ones. There were no significant differences when compared the mean removal efficiency among SACs for each situation, either between the uncorrected and corrected evaporation losses. Statistical analysis ANOVA was applied at 5% significance level in the case where data presented parametric distribution and Kruskal-Wallis at 5% when data were not parametric. COD and BOD experimental data, in both gross and soluble forms, were fitted to the model proposed by Brazil et al. (2007), returning thus the values of equations’ n parameter. Other kinetic models were also fitted to the COD and BOD data in gross and soluble form, corrected and uncorrected, and then it was observed that the first order conventional model did not only present the lowest values for the k organic matter removal coefficient, but also the smallest determination coefficient (R²). It was noticed from the correlation study between the parameters d and n, in all cases, an inverse correlation. The highest correlations observed for n were obtained from the BOD fit to the data in all forms and the lowest correlation to the values of n set to soluble COD data. An association failure was observed among the n and hydraulic detention time (HDT) values in the systems, however, there was a high correlation between n and the organic matter decay rate obtained for the first fifth of CW-HSSFs’ length, indicating that the variable is reduced while the effluent’s relative degradation goes on.
6

Computação gráfica e modelagem computacional aplicadas ao traçado e dimensionamento hidráulico de redes coletoras de esgoto sanitário / Computer graphics and computational modeling applied to the layout and hydraulic design of sewage collection networks

Rodrigues, Gustavo Paiva Weyne 12 May 2006 (has links)
RODRIGUES, G. P. W. Computação gráfica e modelagem computacional aplicadas ao traçado e dimensionamento hidráulico de redes coletoras de esgoto sanitário. 2006. 166 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2016. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-05-11T18:25:52Z No. of bitstreams: 1 2006_dis_gpwrodruigues.pdf: 3731824 bytes, checksum: 052d40eb7b7aead58a8853f33bde7700 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-05-13T14:08:48Z (GMT) No. of bitstreams: 1 2006_dis_gpwrodruigues.pdf: 3731824 bytes, checksum: 052d40eb7b7aead58a8853f33bde7700 (MD5) / Made available in DSpace on 2016-05-13T14:08:48Z (GMT). No. of bitstreams: 1 2006_dis_gpwrodruigues.pdf: 3731824 bytes, checksum: 052d40eb7b7aead58a8853f33bde7700 (MD5) Previous issue date: 2006-05-12 / Brazil is still a country with little scope in relation to sewage systems. Statistics carried out by competent bodies nationwide, as the Modernization Program of Sanitation Sector, prove this fact. With the demand for less expensive projects, of good quality and that they are developed within increasingly shorter periods, we saw the need to create an application called UFC9, capable of accelerating the realization of these projects. For this, we used the most known graphics software tool for engineering, AutoCAD. In this environment, it developed a UFC9 module, aimed at the stroke of collecting sewerage systems. The second module UFC9 presents a computational model that aims to scale hydraulically networks already outlined in the first module, following all the rules established by ABNT. Model validation was made by comparing the calculations for actual sewage networks with data to SANCAD - ESG module, software developed by Sanegraph - Consulting Information Technology and Sanitation Systems. According to the results, the developed program proved to be very satisfactory, enabling use in projects in an easy, intuitive and friendly interface. / O Brasil ainda é um país com pequena abrangência no que se refere aos sistemas de esgotamento sanitário. Estatísticas realizadas por órgãos competentes de âmbito nacional, como o Programa de Modernização do Setor de Saneamento, comprovam este fato. Com a exigência de projetos menos onerosos, de boa qualidade e que sejam elaborados dentro de prazos cada vez menores, viu-se a necessidade de se criar um aplicativo, denominado UFC9, capaz de acelerar a realização destes projetos. Para isto, utilizou-se a ferramenta computacional gráfica mais conhecida para a engenharia, o AutoCAD. Neste ambiente, foi desenvolvido um módulo do UFC9, cujo objetivo é o traçado de redes coletoras de esgotos. O segundo módulo do UFC9 apresenta um modelo computacional que tem a finalidade de dimensionar hidraulicamente as redes já traçadas no primeiro módulo, seguindo todas as normas estabelecidas pela ABNT. A validação do modelo se deu através da comparação dos cálculos para redes de esgoto reais com os dados referentes ao SANCAD – Módulo ESG, software desenvolvido pela Sanegraph – Consultoria em Sistemas de Informática e Saneamento. De acordo com os resultados obtidos, o programa desenvolvido mostrou-se bastante satisfatório, possibilitando o uso em projetos de uma forma fácil, intuitiva e com uma interface amigável.
7

Gestão de agua em edificações : formulação de diretrizes para o reuso de agua para fins não potaveis / Water management in buildings : formulation of guidelines for the reuse water non potable

Boni, Solange da Silva Nunes 14 August 2018 (has links)
Orientador: Marina Sangoi de Oliveira Ilha / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-14T17:19:44Z (GMT). No. of bitstreams: 1 Boni_SolangedaSilvaNunes_D.pdf: 2475928 bytes, checksum: 1748c60492975188a4888d1d5259fbc9 (MD5) Previous issue date: 2009 / Resumo: Varias medidas de conservação de água tem sido adotadas visando minimizar o consumo de água, utilizando este insumo de maneira sustentável e racional, alem de proteger os recursos hídricos da poluição, por meio da geração de menor volume de esgoto. Dentre as linhas de ação dos programas de conservação de água em edifícios, destaca-se o reuso de água em atividades que possam prescindir da potabilidade. No entanto, para isso, e necessário o conhecimento dos diversos usos da água dentro de uma edificação, bem como determinar onde será possível utilizar este insumo, tendo como base um plano de gestão. Este trabalho propõe um conjunto de diretrizes para reuso de água para fins não potáveis em edificações, levando-se em consideração os riscos ocasionados com a utilização desta técnica. O método de pesquisa foi baseado em estudo de caso exploratório, de natureza fenomenológica, contando com duas fontes de evidencias: observação direta e entrevista. O Fator motivador do trabalho e o subsidio de diretrizes para a substituição de água potável por efluentes tratado, de forma a reduzir o consumo da edificação. O trabalho contou um estudo de caso em uma edificação existente, ocorrendo em duas fases distintas: caracterização da edificação e da demanda de água não potável e caracterização da oferta de fontes alternativas e a avaliação dos custos envolvidos para a implantação do sistema de reuso de água. Foi realizada a analise dos estudos e proposta as diretrizes para reuso de água para fins não potáveis, dentro dos contextos estudados. As diretrizes formuladas estão baseadas na complexidade das ações que envolvem a implantação do sistema de reuso, verificando-se a necessidade de estabelecimento de códigos de praticas e normas para implantar o referido sistema. / Abstract: Various measures to conserve water have been taken to minimize water consumption, using this input for sustainable and rational way, and protect water resources from pollution through the generation of lower quantity of sewage. Among the lines of action programs for water conservation in buildings, is the use of alternative sources to the public in activities that can disperse the drinking. However, for this reason it is necessary to know the various uses of water within a building and determine where you can use this input, based on a management plan. This paper proposes a set of guidelines for reuse of non-potable water in buildings, taking into account the risks incurred by using this technique. The research method was based on exploratory case study, a phenomenological, with two sources of evidence: direct observation and interview. The motivating factor is the work of the subsidy guidelines for the replacement of drinking water by treated effluent, to reduce the consumption of the building. The work had two case studies, one in an existing building and the other in design, occurring in two distinct phases: construction and characterization of the demand for non-drinking water and characterization of alternative sources of supply and assessment of the costs involved for deployment of the system for reuse of water. We performed the analysis of the studies and proposed guidelines for reuse of non-potable water, within the contexts studied. The guidelines are formulated based on the complexity of actions involving the deployment of the system for reuse, there is a need to establish codes of practice and standards to implement the system. / Doutorado / Arquitetura e Construção / Doutor em Engenharia Civil
8

Qualidade de investimentos em sistemas prediais de aproveitamento de água pluvial : uso de particles swarm optimization / Quality of investments in rainwater harvesting systems : use of particles swarm optimization

Campos, Marcus André Siqueira 20 August 2018 (has links)
Orientador: Marina Sangoi de Oliveira Ilha / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-20T11:57:01Z (GMT). No. of bitstreams: 1 Campos_MarcusAndreSiqueira_D.pdf: 2890130 bytes, checksum: 1dd550889b35580500ff1fcbf1bf6c8e (MD5) Previous issue date: 2012 / Resumo: Os sistemas prediais de aproveitamento de água pluvial tem como objetivos possibilitar o uso de fontes alternativas de água em atividades que prescindam da água potável nas edificações e também contribuir para a redução do escoamento superficial ocasionado pela impermeabilização do solo dos centros urbanos. O uso desses e de outros sistemas relacionados com a conservação de água nas edificações pode ser também atrativo do ponto de vista econômico, do que resulta um maior incentivo para a sua implementação. Para tanto, a análise da qualidade dos investimentos nesses sistemas deve ser considerada na tomada da decisão pela implantação de medidas voltadas para a mitigação do impacto ambiental da construção dos edifícios. O presente trabalho tem como objetivo propor uma ferramenta para a análise da qualidade de investimentos em sistemas prediais de aproveitamento de água pluvial, baseada na otimização do valor presente líquido dos investimentos necessários. Para tanto, é proposto o uso da técnica da Particle Swarm Optimization. A ferramenta desenvolvida foi utilizada para a avaliação da qualidade dos investimentos em sistemas prediais de aproveitamento de água pluvial em edificações representativas de três categorias tarifárias: pública, comercial e industrial. Os resultados obtidos indicam as oportunidades de investimentos nos referidos sistemas, a partir da consideração de cenários que contemplam ou não a cobrança da tarifa de esgoto decorrente do uso dessa fonte alternativa / Abstract: The main purposes of a Rainwater Harvesting systems is to allow the use of alternative water sources where potable water is not necessary and to contribute to reduce the surface runoff caused by the impervious areas in urban centers. The use of this system or any other technology that promotes water conservation in buildings can also be economically feasible, resulting in more incentives for their implementation. To achieve this goal, the quality of the investment's analysis must be considered when the decision making process is occurring, that way, the reduction of the impacts caused by is encouraging. The present work aims to propose a tool to analyze the quality of investments in rainwater harvesting systems, based on optimizing the net present value of the investments realized. It was proposed the use of the Particle Swarm Optimization technique. The developed tool was used to evaluate the quality of investments in buildings that uses rainwater representing three tariff categories: public, commercial and industrial. The results indicate the opportunities for invest in those systems, specially those scenarios that include or not the sewage rate , resulting from the use of this alternative water source / Doutorado / Edificações / Doutor em Engenharia Civil
9

Avaliação do uso de agua em edificios escolares publicos e analise de viabilidade economica da instalação de tecnologias economizadoras nos pontos de consumo / Water use evaluation in public schools buildings and economic feasibility analysis of installation of water saving technologies

Ywashima, Lais Aparecida 23 February 2005 (has links)
Orientador: Marina Sangoi de Oliveira Ilha / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-04T11:15:45Z (GMT). No. of bitstreams: 1 Ywashima_LaisAparecida_M.pdf: 4111482 bytes, checksum: 8b37c02d441b73933d2437667f623e43 (MD5) Previous issue date: 2005 / Resumo: O volume de água consumido em uma edificação, constante na conta de água, pode ser dividido em duas parcelas: o uso propriamente dito e o desperdício. O desperdício pode ocorrer tanto pela ocorrência de vazamentos como pelo mau uso desse insumo nas diferentes atividades realizadas. Em edificações escolares públicas, é freqüente o uso não racional desse insumo, uma vez que os usuários não são os responsáveis diretos pelo pagamento da conta de água. Inserido nesse contexto, o presente trabalho apresenta a metodologia e os resultados obtidos em uma investigação de campo realizada com o objetivo de identificar a forma de realização das diferentes atividades que envolvem o uso da água em uma amostra de escolas da rede pública de Campinas, com a indicação dos ambientes responsáveis pelas maiores parcelas do consumo e a proposição de uma metodologia para a avaliação qualitativa da percepção dos usuários para o uso racional de água nessa tipologia de edificação. Além disso, tendo em vista que uma das ações para a implementação do uso racional consiste na instalação de tecnologias economizadoras nos pontos de consumo de água e que o fator motivador para a implementação desse tipo de intervenção é, na maioria das vezes, de ordem financeira, apresenta-se um método para a avaliação econômica dos investimentos necessários para tanto / Abstract: The water consumption, which is printed in water bills can be divided in two parts: the use itself and waste. The waste is usually due to leaking events or bad use of tap water in several daily activities. In public schools buildings, it¿s often the irrational use of water due the user is not directly responsible for paying the water bill. In this context, the present research presents the methodology and results obtained in a field survey that was done to identify different ways of water use in a sample of public schools from Campinas, Sao Paulo, and it also be done the identification of which environments are responsible for higher portions of the water consumption and the proposition of a methodology to evaluate the users perception for the rational use of water at this building type. Moreover, one of the alternatives to achieve the rational use of water is the installation of water saving technologies at consumption points and the motivator reason to the implementation of these devices it is, normally, financial issues, then, this work shows a method to evaluate economic feasibility of the essential investments to do it / Mestrado / Edificações / Mestre em Engenharia Civil
10

Diretrizes para formulação de método hierarquizado para investigação de patologias em sistemas prediais hidráulicos e sanitários / Guidelines for the formulation of a hierarchized method for investigation of building plumbing and drainage systems pathologies

Gnipper, Sérgio Frederico 16 August 2018 (has links)
Orientador: Marina Sangoi de Oliveira Ilha / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-16T21:41:55Z (GMT). No. of bitstreams: 1 Gnipper_SergioFrederico_M.pdf: 8224325 bytes, checksum: 04186a60ef4b9f83deeb75fca0ae6c62 (MD5) Previous issue date: 2010 / Resumo: Os sistemas prediais hidráulicos e sanitários (SPHS) vêm comparecendo com relevante frequência em resultados de levantamentos de manifestações patológicas. Em geral, as patologias de maior incidência não envolvem sérios riscos à vida ou à saúde, mas podem causar aborrecimentos e desconforto decorrentes dos sintomas comuns de suas manifestações. Contudo, algumas patologias podem propiciar a propagação de microorganismos potencialmente patogênicos dentro dos próprios componentes, como os causadores de legioneloses e da síndrome respiratória severa aguda. Este quadro mostra a importância de um método adequado para a investigação, supressão e prevenção desse gênero de patologias. Existem métodos formulados para a investigação de patologias construtivas genéricas nas edificações, mas que não incorporam etapas e recursos importantes para a adequada solução de problemas frequentes nos sistemas prediais hidráulicos e sanitários, como a ênfase na sintomatologia e o exame detalhado do projeto para o estabelecimento do diagnóstico, além da priorização das propostas de intervenções corretivas e preventivas. Neste trabalho faz-se uma análise comparativa de alguns desses métodos, estabelecendo um paralelo com o MASP-PDCA, e propõe-se diretrizes para a formulação de um método hierarquizado para investigação de patologias em SPHS a partir de estudo de casos múltiplos de levantamentos patológicos em edifícios localizados no município de Curitiba, além de sugerir meios para a prevenção de patologias freqüentes verificadas nos SPHS, visando a melhoria da qualidade. Com isto, espera-se contribuir para o desenvolvimento de uma ferramenta útil tanto para a manutenção do desempenho ao longo da vida útil do edifício como para retroalimentar o processo de projeto / Abstract: Building Plumbing and Drainage Systems are expressively frequent in pathologic manifestation survey results. Most assiduous problems are not generally related to serious life and health risks but use to cause annoyance and discomfort due to their characteristic symptoms. However some of these pathologies may cause propagation of potentially pathogenic microorganisms at those system components, such as legionellosis and Severe Acute Respiratory Syndrome. This situation reveals the importance of an adequate method for investigation, suppression e prevention of these kinds of pathologies. There are methods formulated for general building pathology investigations, but they do not aggregate stages and resources relevant for the solution of frequent problems of building plumbing and drainage systems, such as the emphasis on symptomatology and detailed design analysis in order to set diagnosis as well as to establish priority for corrective and preventive interventions. This work makes a comparative analysis of some of those methods and draws a parallel with PDCA method regarding further proposition of guidelines for the formulation of a hierarchized method for the investigation of building plumbing and drainage system pathologies based upon multiple case studies of buildings at Curitiba City. Moreover it suggests feedback means for the prevention of frequent pathologies of building plumbing and drainage systems in order to improve quality. The aim of this work is to contribute to the development of an useful tool to maintain serviceable lifetime building performance and help design process feedback / Mestrado / Arquitetura e Construção / Mestre em Engenharia Civil

Page generated in 0.2538 seconds