• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1
  • Tagged with
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Construção de um espectrômetro de absorção atômica e estudos de formação e evolução da nuvem atômica com atomização eletrotérmica em sistema de duplo filamento de tungstênio / Construction of an atomic absorption spectrometer and studies on the formation and evolution of the atomic cloud with electrothermal atomization in a double tungsten coil system

Jora, Manassés Zuliani, 1987- 25 August 2018 (has links)
Orientadores: Celio Pasquini, Joaquim de Araújo Nóbrega / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-25T12:04:34Z (GMT). No. of bitstreams: 1 Jora_ManassesZuliani_M.pdf: 4929889 bytes, checksum: f8da5d6a35fbac5ae2d05d997971561a (MD5) Previous issue date: 2013 / Resumo: A espectrometria de absorção atômica com atomização eletrotérmica (ET AAS) é adequada para a determinação de metais e semimetais, apresentando alta sensibilidade. Dentre os atomizadores eletrotérmicos, os fornos de grafite destacam-se por sua boa seletividade, exigência de pequenos volumes de amostra e baixos limites de detecção (i.e. 'mu'g L-1). Porém, esses atomizadores requerem fontes de alta potência (i.e. superiores a 2 kW), sistema de resfriamento e, ainda, apresentam alto custo. Como alternativa, o uso de superfícies metálicas têm sido objeto de pesquisa desde 1970. Dentre todos os metais empregados na fabricação de superfícies metálicas e utilizados para os estudos em ET AAS, o tungstênio é o que vem apresentando maior aplicação. Porém, a espectrometria de absorção atômica baseada em atomizadores de filamento de tungstênio (WC AAS) apresenta vários desafios relacionados ao entendimento da geração da nuvem atômica e dos efeitos de interferência observados. Dessa maneira, neste trabalho construiu-se um espectrômetro de absorção atômica com duplo filamento de tungstênio (DWC AAS), com duas configurações, uma empregando como sistema de detecção um sistema echelle/detector de carga acoplada intensificado (ICCD) e outra um sistema filtro óptico-acústico sintonizável (AOTF)/fotomultiplicadora. Essas duas configurações do equipamento foram empregadas em estudos de formação e evolução da nuvem atômica de elementos com características voláteis e refratárias (i.e. Pb e Cr). Além disso, estudou-se o efeito de Na, K, Ca e Mg, em três diferentes concentrações (i.e. 1, 10 e 100 mg L-1) sobre os perfis das nuvens atômicas de Pb e Cr. Esse estudo foi conduzido de tal forma que interferências em fase condensada e gasosa puderam ser avaliadas. Além disso, o equipamento foi empregado em medidas de temperatura na superfície do filamento e na fase gasosa / Abstract: Electrothermal atomic absorption spectrometry (ET AAS) is suitable for determination of metals and semimetals with high sensitivity. Among the existing electrothermal atomizers, graphite furnace stands out due to its selectivity, requirement of low volume of sample and low limits of detection (i.e. 'mu'g L-1). Notwithstanding, these atomizers present high cost and requires high power power supply (i.e. above 2 kW) and a cooling system. Alternatively, metallic surfaces have been studied since 1970. Among all metals employed as atomizers in ET AAS studies, tungsten has presented the best results and has found many analytical applications. However, tungsten coil atomic absorption spectrometry (WC AAS) presents several challenges related to understanding the atomic cloud generation and interferences effects. Thus, in this work, a double tungsten coil atomic absorption spectrometer (DWC AAS), with two different configurations was constructed. In one configuration, a detection system based on echelle/intensified charge-coupled device (ICCD) is employed and, in the other, an acousto-optic tunable filter (AOTF)/photomultiplier detection system is used. Both configurations were employed in the atomic cloud generation and evolution studies of Pb and Cr. Furthermore, interferences on the atomic cloud profile of Pb and Cr caused by Na, K, Ca and Mg, at three different concentrations (i.e. 1, 10 and 100 mg L-1), were studied. This study helped to evaluate the effect of condensed and gas phase interferences. Additionally, the equipment was employed to perform measures of surface and gas phase temperatures / Mestrado / Quimica Analitica / Mestre em Química
2

Projeto e avaliação de um modulador criogenico para cromatografia gasosa bidimensional abrangente (GC x GC) / Development and evaluation of a cryogenic modulator for comprehensive two-dimensional gas chromatography (GC X GC)

Pedroso, Marcio Pozzobon 15 August 2018 (has links)
Orientador: Fabio Augusto / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-15T02:24:41Z (GMT). No. of bitstreams: 1 Pedroso_MarcioPozzobon_D.pdf: 8593602 bytes, checksum: ef9b8a25b7ff1f1f8fdec875ceb02e0f (MD5) Previous issue date: 2009 / Resumo: O objetivo do trabalho foi projetar e avaliar um modulador criogênico para cromatografia gasosa bidimensional abrangente (GC×GC). O modulador projetado foi baseado no modulador de quatro jatos (dois jatos quentes e dois jatos frios); N2 (g) resfriado em N2 (l) foi utilizado como fluido criogênico e N2 (g) aquecido foi utilizado como gás quente. O modulador foi instalado em um cromatógrafo a gás com detector por ionização em chama (GC-FID). O controle das válvulas solenóides e a digitalização do sinal analógico do FID foram realizados por software escrito em ambiente LabVIEW. Os resultados obtidos com o protótipo GC×GC-FID foram comparados com dados obtidos em um GC×GC-FID comercial. O desempenho de ambos os sistemas pode ser considerado equivalente, levando em consideração eficiência cromatográfica e repetibilidade. O protótipo GC×GC-FID foi empregado na análise de diversas amostras, em especial a fração volátil de polpa de abacaxi fresco e desidratado. Os voláteis foram extraídos por microextração em fase sólida através da extração dinâmica do headspace (DHS-SPME). A identificação dos compostos foi feita por cromatografia gasosa acoplada a espectrometria de massas (GC-MS) e avaliação dos índices de retenção. A identificação dos picos no cromatograma GC×GC foi feita através da comparação dos índices de retenção e dos perfis cromatográficos previamente obtidos por GC-MS. Como esperado, a análise por GC×GC-FID apresentou maior detectabilidade e poder de separação quando comparada com GC-FID. Por fim, alguns compostos não identificados por GC-MS foram identificados através de informação obtida pela estruturação cromatográfica da GC×GC. / Abstract: The aim of this project was to develop and evaluate a cryogenic modulator for comprehensive two-dimensional gas chromatography (GC×GC). The design of the modulator was based on a cryogenic quad jet modulator; N2 (g) cooled with N2 (l) was used as the cryogenic fluid and heated N2 (g) was used as the hot gas. The modulator was fitted into a gas chromatograph equipped with a flame ionization detector (GC-FID). The control of the solenoid valves and digitalization of the analogic FID signal were performed by software written in the LabVIEW platform. Results obtained with the GC×GC-FID prototype were compared with data from a commercial GC×GC-FID system. The performance of both systems was similar regarding chromatographic efficiency and repeatibility. The GC×GC-FID was employed for analysis of several samples, specially volatile organic compounds of fresh and dried pineapple pulp. The analytes were isolated by dynamic headspace solid phase microextraction (D-HSSPME); identification of the compounds was performed by conventional gas chromatography coupled to mass spectrometry (GC-MS) and evaluation of retention indexes. The identification of the peaks on the GC×GC chromatograms was carried out by comparison of retention indexes and chromatographic profiles previously obtained by GC-MS. As expected, the detectivity and separation power of the GC×GC-FID analysis was significantly better than that of GC-FID. Moreover, the identity of some compounds not identified by GC-MS was assigned after information obtained from GC×GC chromatographic structure. / Doutorado / Quimica Analitica / Doutor em Ciências

Page generated in 0.1084 seconds