Stanovení rubidia ve vybraných rostlinných extraktech pomocí atomové absorpční spektrometrie / Determination of rubidium in selected plant extracts by atomic absorption spectrometryŠatrová, Lucie January 2019 (has links)
In this diploma thesis, rubidium in plant material samples was determined by atomic absoption spectrometry. Determination of plant material rubidium was performed on two different atomic absorption spectrometers (GBC 933 AA and ContrAA 700) for comparison. The selection of a proper method of atomization was essential, therefore optimizations for the flame atomizer and electrothermal atomizer were performed. On the GBC 933 AA, flame atomization was tested. The flow rate of the acetylene-air, vertical and horizontal flame profile, spectral interval width was optimized for the instrument. On the ContrAA 700, the conditions for flame atomization were optimized as well as for electrothermal atomization. The optimized parameters included the acetylene-air flow rate and the vertical flame profile again. For the electrothermal atomization, the temperature dependence of pyrolysis and the temperature dependence of atomization were optimized. Under experimentally determined optimal conditions, the determination of rubidium in fruit and vegetable juice samples was performed by the method of calibration curve. Rubidium usually accompanies toher alkali metals. In the absence of essential biogenic elements iportant for plant growth, rubidium is able to help out and take on the role of potassium.
|
2 |
Construção de um espectrômetro de absorção atômica e estudos de formação e evolução da nuvem atômica com atomização eletrotérmica em sistema de duplo filamento de tungstênio / Construction of an atomic absorption spectrometer and studies on the formation and evolution of the atomic cloud with electrothermal atomization in a double tungsten coil systemJora, Manassés Zuliani, 1987- 25 August 2018 (has links)
Orientadores: Celio Pasquini, Joaquim de Araújo Nóbrega / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Química / Made available in DSpace on 2018-08-25T12:04:34Z (GMT). No. of bitstreams: 1
Jora_ManassesZuliani_M.pdf: 4929889 bytes, checksum: f8da5d6a35fbac5ae2d05d997971561a (MD5)
Previous issue date: 2013 / Resumo: A espectrometria de absorção atômica com atomização eletrotérmica (ET AAS) é adequada para a determinação de metais e semimetais, apresentando alta sensibilidade. Dentre os atomizadores eletrotérmicos, os fornos de grafite destacam-se por sua boa seletividade, exigência de pequenos volumes de amostra e baixos limites de detecção (i.e. 'mu'g L-1). Porém, esses atomizadores requerem fontes de alta potência (i.e. superiores a 2 kW), sistema de resfriamento e, ainda, apresentam alto custo. Como alternativa, o uso de superfícies metálicas têm sido objeto de pesquisa desde 1970. Dentre todos os metais empregados na fabricação de superfícies metálicas e utilizados para os estudos em ET AAS, o tungstênio é o que vem apresentando maior aplicação. Porém, a espectrometria de absorção atômica baseada em atomizadores de filamento de tungstênio (WC AAS) apresenta vários desafios relacionados ao entendimento da geração da nuvem atômica e dos efeitos de interferência observados. Dessa maneira, neste trabalho construiu-se um espectrômetro de absorção atômica com duplo filamento de tungstênio (DWC AAS), com duas configurações, uma empregando como sistema de detecção um sistema echelle/detector de carga acoplada intensificado (ICCD) e outra um sistema filtro óptico-acústico sintonizável (AOTF)/fotomultiplicadora. Essas duas configurações do equipamento foram empregadas em estudos de formação e evolução da nuvem atômica de elementos com características voláteis e refratárias (i.e. Pb e Cr). Além disso, estudou-se o efeito de Na, K, Ca e Mg, em três diferentes concentrações (i.e. 1, 10 e 100 mg L-1) sobre os perfis das nuvens atômicas de Pb e Cr. Esse estudo foi conduzido de tal forma que interferências em fase condensada e gasosa puderam ser avaliadas. Além disso, o equipamento foi empregado em medidas de temperatura na superfície do filamento e na fase gasosa / Abstract: Electrothermal atomic absorption spectrometry (ET AAS) is suitable for determination of metals and semimetals with high sensitivity. Among the existing electrothermal atomizers, graphite furnace stands out due to its selectivity, requirement of low volume of sample and low limits of detection (i.e. 'mu'g L-1). Notwithstanding, these atomizers present high cost and requires high power power supply (i.e. above 2 kW) and a cooling system. Alternatively, metallic surfaces have been studied since 1970. Among all metals employed as atomizers in ET AAS studies, tungsten has presented the best results and has found many analytical applications. However, tungsten coil atomic absorption spectrometry (WC AAS) presents several challenges related to understanding the atomic cloud generation and interferences effects. Thus, in this work, a double tungsten coil atomic absorption spectrometer (DWC AAS), with two different configurations was constructed. In one configuration, a detection system based on echelle/intensified charge-coupled device (ICCD) is employed and, in the other, an acousto-optic tunable filter (AOTF)/photomultiplier detection system is used. Both configurations were employed in the atomic cloud generation and evolution studies of Pb and Cr. Furthermore, interferences on the atomic cloud profile of Pb and Cr caused by Na, K, Ca and Mg, at three different concentrations (i.e. 1, 10 and 100 mg L-1), were studied. This study helped to evaluate the effect of condensed and gas phase interferences. Additionally, the equipment was employed to perform measures of surface and gas phase temperatures / Mestrado / Quimica Analitica / Mestre em Química
|
3 |
Avaliação da espectrometria de absorção atômica com atomização eletrotérmica em filamento de tungstênio para determinação de arsênio em águas / Evaluation of eletrothermal atomic absorption spectrometry with tungsten coil for the direct determination of arsenic in watersAntonio, Rosana Fernandes 19 September 2008 (has links)
A determinação direta de arsênio total em águas por espectrometria de absorção atômica com filamentos de tungstênio (150 W) modificados quimicamente com irídio ou ródio, representa uma alternativa para a atomização eletrotérmica de arsênio, que foi avaliada na presente dissertação. A utilização do revestimento com Ir como modificador químico proporcionou um aumento da massa característica de arsênio de 3,5 vezes. As medidas foram feitas com altura de observação selecionada para proporcionar a melhor razão sinal/ruído sem diminuir a sensibilidade do sinal analítico. Avaliaram-se dois programas de aquecimento: com temperatura de secagem constante (com diminuição gradativa da tensão aplicada) e com temperatura de secagem variável (com tensão aplicada de maneira constante). Não houve diferença na sensibilidade entre os dois programas estudados, indicando que a modificação química leva à formação de um precursor atômico com estabilidade térmica elevada. De fato, utilizando-se a modificação química permanente com 1000 müg Ir, e adotando-se programa de aquecimento com temperatura de secagem variável, a temperatura máxima de pirólise foi de aproximadamente 1700 °C ( temperatura de atomização de 2700 °C). Avaliou-se o comportamento eletrotérmico do As na presença dos concomitantes Na, K, Ca e Mg em 0,1% v/v HNO3. Interferências mais severas foram observadas na presença de cálcio acima de 10 \'mü\'g l-1, e acima de 100 \'mü\'g l-1 para os demais concomitantes. As interferências podem estar relacionadas com o elevado gradiente de temperatura entre a superfície do filamento e a fase gasosa do volume de observação, ou mesmo devido à formação de compostos refratários, particularmente para Ca e Mg, na fase condensada, ou seja, na superfície do atomizador. O emprego do método das médias móveis no tratamento dos sinais transientes gerados na atomização do arsênio também foi avaliada. Com o filamento posicionado na altura de observação 2 mm, foram utilizados os fatores 0, 3, 5, 7 e 9, observando-se melhora considerável nos limites de detecção instrumental e do método,utilizando-se média móvel com fator 7. Nestas condições, e depositando-se 20 \'mü\'l de amostra sobre o filamento, o limite de detecção foi de 3,2 \'mü\'g l-1 As e a massa característica de 37,0 pg As. A exatidão foi avaliada analisando-se diferentes amostras de águas provenientes da região do Quadrilátero Ferrífero do Estado de Minas Gerais, por espectrometria de fluorescência atômica com geração de hidretos e por espectrometria de absorção atômica com o filamento de tungstênio modificado com Ir. A comparação dos resultados mostrou que o método proposto pode ser utilizado para o controle de qualidade de águas desta região. Aproximadamente 150 queimas podem ser feitas com um único filamento de tungstênio / The direct determination of arsenic in waters by atomic absorption spectrometry with 150 W tungsten coils, treated with Ir or Rh, was evaluated as a possible alternative for the eletrothermal atomization of As. The use of iridium as a permanent chemical modifier did improve the characteristic mass of arsenic by 3.5 fold. Measurements were made by choosing an appropriate observation height in order to get the best signal to noise ratio. Two heating programs were tested, either by keeping the applied voltage constant or by using an inverted voltage ramp during the drying step. There were no significant differences in the sensitivities between both heating programs, indicating that the permanent modification lead to the formation of an atomic precursor of high thermal stability. Indeed, with the permanent chemical modification with 1000 \'mü\'g Ir, the maximum pyrolysis temperature was approximately 1700 °C (atomization temperature 2700 °C), allowing a heating program with temperature variation during the drying step. Method selectivity was carried out by evaluating the eletrothermal behavior of As in the presence of up to 1000 \'mü\'g l-1 Na, K, Ca and/or Mg in 0,1% v/v HNO3. The most serious interferences were observed with Ca in concentrations higher than 10 \'mü\'g l-1 and when the concentrations were higher than 100 \'mü\'g l-1 for Na, K or Mg, which can be attributed either to the gradient of temperature between the surface of the atomizer and the observation volume or to the formation of refractory compounds in the condensed phase, particularly with Ca and Mg. The absorbance transient signals treatment by the method of moving averages up to factor 9 was also evaluated, with a remarkable improvement in the instrumental and method detection limits. With the center of the observation volume 2 mm above the tungsten coil surface, and a moving average of factor 7, the limit of detection was 3,2 \'müg\' l-1 As and the characteristic mass 37,0 pg As. Accuracy was evaluate by analysing water samples collected in a contaminated area from the Quadrilátero Ferrífero, Minas Gerais State, by hydride generation atomic fluorescence spectrometry and by tungsten coil eletrothermal atomic absorption spectrometry. Results showed that the proposed method fits for the purpose of CONAMA 357 regulation for drinking water quality in the aforementioned contaminated area. Approximately 150 firings can be done with a single tungsten coil atomizer by using 20 \'mü\'l sample volume
|
4 |
Avaliação da espectrometria de absorção atômica com atomização eletrotérmica em filamento de tungstênio para determinação de arsênio em águas / Evaluation of eletrothermal atomic absorption spectrometry with tungsten coil for the direct determination of arsenic in watersRosana Fernandes Antonio 19 September 2008 (has links)
A determinação direta de arsênio total em águas por espectrometria de absorção atômica com filamentos de tungstênio (150 W) modificados quimicamente com irídio ou ródio, representa uma alternativa para a atomização eletrotérmica de arsênio, que foi avaliada na presente dissertação. A utilização do revestimento com Ir como modificador químico proporcionou um aumento da massa característica de arsênio de 3,5 vezes. As medidas foram feitas com altura de observação selecionada para proporcionar a melhor razão sinal/ruído sem diminuir a sensibilidade do sinal analítico. Avaliaram-se dois programas de aquecimento: com temperatura de secagem constante (com diminuição gradativa da tensão aplicada) e com temperatura de secagem variável (com tensão aplicada de maneira constante). Não houve diferença na sensibilidade entre os dois programas estudados, indicando que a modificação química leva à formação de um precursor atômico com estabilidade térmica elevada. De fato, utilizando-se a modificação química permanente com 1000 müg Ir, e adotando-se programa de aquecimento com temperatura de secagem variável, a temperatura máxima de pirólise foi de aproximadamente 1700 °C ( temperatura de atomização de 2700 °C). Avaliou-se o comportamento eletrotérmico do As na presença dos concomitantes Na, K, Ca e Mg em 0,1% v/v HNO3. Interferências mais severas foram observadas na presença de cálcio acima de 10 \'mü\'g l-1, e acima de 100 \'mü\'g l-1 para os demais concomitantes. As interferências podem estar relacionadas com o elevado gradiente de temperatura entre a superfície do filamento e a fase gasosa do volume de observação, ou mesmo devido à formação de compostos refratários, particularmente para Ca e Mg, na fase condensada, ou seja, na superfície do atomizador. O emprego do método das médias móveis no tratamento dos sinais transientes gerados na atomização do arsênio também foi avaliada. Com o filamento posicionado na altura de observação 2 mm, foram utilizados os fatores 0, 3, 5, 7 e 9, observando-se melhora considerável nos limites de detecção instrumental e do método,utilizando-se média móvel com fator 7. Nestas condições, e depositando-se 20 \'mü\'l de amostra sobre o filamento, o limite de detecção foi de 3,2 \'mü\'g l-1 As e a massa característica de 37,0 pg As. A exatidão foi avaliada analisando-se diferentes amostras de águas provenientes da região do Quadrilátero Ferrífero do Estado de Minas Gerais, por espectrometria de fluorescência atômica com geração de hidretos e por espectrometria de absorção atômica com o filamento de tungstênio modificado com Ir. A comparação dos resultados mostrou que o método proposto pode ser utilizado para o controle de qualidade de águas desta região. Aproximadamente 150 queimas podem ser feitas com um único filamento de tungstênio / The direct determination of arsenic in waters by atomic absorption spectrometry with 150 W tungsten coils, treated with Ir or Rh, was evaluated as a possible alternative for the eletrothermal atomization of As. The use of iridium as a permanent chemical modifier did improve the characteristic mass of arsenic by 3.5 fold. Measurements were made by choosing an appropriate observation height in order to get the best signal to noise ratio. Two heating programs were tested, either by keeping the applied voltage constant or by using an inverted voltage ramp during the drying step. There were no significant differences in the sensitivities between both heating programs, indicating that the permanent modification lead to the formation of an atomic precursor of high thermal stability. Indeed, with the permanent chemical modification with 1000 \'mü\'g Ir, the maximum pyrolysis temperature was approximately 1700 °C (atomization temperature 2700 °C), allowing a heating program with temperature variation during the drying step. Method selectivity was carried out by evaluating the eletrothermal behavior of As in the presence of up to 1000 \'mü\'g l-1 Na, K, Ca and/or Mg in 0,1% v/v HNO3. The most serious interferences were observed with Ca in concentrations higher than 10 \'mü\'g l-1 and when the concentrations were higher than 100 \'mü\'g l-1 for Na, K or Mg, which can be attributed either to the gradient of temperature between the surface of the atomizer and the observation volume or to the formation of refractory compounds in the condensed phase, particularly with Ca and Mg. The absorbance transient signals treatment by the method of moving averages up to factor 9 was also evaluated, with a remarkable improvement in the instrumental and method detection limits. With the center of the observation volume 2 mm above the tungsten coil surface, and a moving average of factor 7, the limit of detection was 3,2 \'müg\' l-1 As and the characteristic mass 37,0 pg As. Accuracy was evaluate by analysing water samples collected in a contaminated area from the Quadrilátero Ferrífero, Minas Gerais State, by hydride generation atomic fluorescence spectrometry and by tungsten coil eletrothermal atomic absorption spectrometry. Results showed that the proposed method fits for the purpose of CONAMA 357 regulation for drinking water quality in the aforementioned contaminated area. Approximately 150 firings can be done with a single tungsten coil atomizer by using 20 \'mü\'l sample volume
|
5 |
Analýza nanočásticových systémů atomovou spektrometrií / Analysis of nanopartical systems by atomic spectrometryJeníková, Eva January 2018 (has links)
EN The present diploma thesis is focused on optimization methods of titanium and phosphorus concentration for their use in the colloidal solution of TiO2 nanoparticles modified by bisphosphonates. For these analyses was used atomic absorption spectrometry with flame and electrothermal atomization. The characteristics of the two analytes were compared to two different spectrometers. Using the F-AAS technique on the GBC 933 AA spectrometer has been achieved a detection limit of 5,2 mg l-1 for titanium and a detection limit of 163 mg l-1 for the phosphorus. Using the ContrAA 700 spectrometer, F-AAS has been achieved an almost five times lower detection limit of 1,1 mg l-1 for titanium determination. For determination of phosphorus using this spectrometer, was obtained a similar value of 151 mg l-1 , as using the GBC 933 AA spectrometer. The determination of phosphorus by the ET-AAS technique using the ContrAA 700 spectrometer resulted in a detection limit of 1,23 mg l-1 , which is a significant difference compared to the flame system. It has been proved that optimized methods are consistent with the intention, which was confirmed by the analysis of real titanium and phosphorus samples in the colloidal solution of TiO2 nanoparticles modified bisphosphonates.
|
6 |
Estudo da utilização de padrão interno em determinações multielementares por espectrometria de absorção atômica com atomização eletrotérmica e detecção simultânea / Study of the use of internal standard for multielement determinations by electrothermal atomic absorption spectrometry with simultaneous detectionCorreia, Paulo Rogério Miranda 23 July 2004 (has links)
Um estudo sistemático a respeito da utilização de padrão interno em determinações multielementares por espectrometria de absorção atômica (ETAAS) foi desenvolvido. O objetivo principal do presente trabalho foi verificar a possibilidade de melhorar a precisão e a exatidão dos resultados analíticos, que são obtidos na análise de fluidos biológicos. O pré-tratamento dessas amostras foi simplificado e reduzido a uma única etapa de diluição com surfactante (Triton X-100) e ácido (HNO3). Conseqüentemente, a complexidade da solução diluída de amostra, a ser introduzida no tubo de grafite, apresenta uma elevada quantidade de concomitantes que podem provocar interferências químicas. A seleção preliminar dos elementos a serem testados como padrão interno considerou a semelhança de parâmetros físico-químicos relacionados com o processo de atomização. Desta forma, Ag, Bi, In e Tl foram testados como padrão interno para a determinação simultânea de Cd/Pb em sangue e urina, enquanto Bi, Ge, In, Sb, Sn e Te foram os elementos selecionados para a determinação de Mn/Ni/Se em soro sangüíneo. A melhoria da qualidade dos resultados analíticos obtidos na determinação simultânea de Cd e Pb em sangue foi observada quando Ag foi utilizada como padrão interno, na presença de NH4H2PO4 como modificador químico. Verificou-se uma melhoria na exatidão dos resultados obtidos para Cd e Pb, após a correção com padrão interno. Por outro lado, os resultados obtidos na análise de urina não foram corrigidos por nenhum dos elementos testados. Os melhores resultados para a determinação simultânea de Mn, Ni e Se foram obtidos com a utilização de Bi, Sn e Te como padrão interno. Entretanto, verificou-se que a correção de todos os resultados não seria viável com o uso de um único padrão interno. O melhor desempenho nos testes realizados na presença de soro sangüíneo foi obtido com Bi, que melhorou discretamente a precisão dos resultados obtidos para Se. Desta forma, a padronização interna visando a determinação simultânea de Mn, Ni e Se não foi eficiente. A padronização interna em ETAAS, com a finalidade de melhorar a precisão e a exatidão dos resultados analíticos, é uma estratégia tão complexa, quanto os efeitos interferentes que se pretende corrigir: são necessários mais estudos para compreender melhor como a utilização de uma condição de compromisso afeta os processos de atomização, bem como mais informações a respeito das interferências físicas e químicas causadas por amostras complexas, analisadas por ETAAS após uma simples etapa de diluição. Deve-se considerar com especial atenção o modificador químico e as temperaturas das etapas de pirólise e de atomização empregadas, que são parâmetros críticos para o desempenho de um elemento como padrão interno. / A systematic study involving the use of internal standard for multielement determinations by electrothermal atomic absorption spectrometry was developed. The main objective of this work was evaluate the possibility of improving precision and accuracy of the analytical results for biological fluids. The sample pre-treatment was reduced to a single dilution step with surfactant (Triton X-100) and acid (HNO3), increasing the amount of concomitant introduced into the atomizer. The preliminary selection of the elements to be tested as internal standard considered the resemblance of physico-chemical parameters related with the atomization process. Thus, Ag, Bi, In and Tl were tested as internal standard for the simultaneous determination of Cd/Pb in blood and urine, and Bi, Ge, In, Sb, Sn and Te were the selected elements for the determination of Mn/Ni/Se in blood serum. The correction of the results obtained for the simultaneous determination of Cd and Pb in blood was achieved when Ag was used as internal standard, in presence of NH4H2PO4 as chemical modifier. An improvement for the accuracy of the results was observed for both analytes after their correction with the internal standard. On the other hand, the results obtained for the urine analysis were not corrected by using the tested elements. The best results for the simultaneous determination of Mn, Ni and Se were observed when Bi, Sn and Te were used as internal standard. However, the correction for the results for all analytes was not possible by using only one internal standard. The best performance in presence of the serum was obtained for Bi, which improves slightly the precision for the Se results. Thus, the internal standardization for the simultaneous determination of Mn, Ni and Se was not efficient. The internal standardization in ETAAS, aiming the improvement of precision and accuracy of the analytical results, is a strategy as complex as the interference effects to be corrected: more studies are required in order to better understand how the adoption of a compromised condition disturbs the atomization processes, as well as to get more information about the physical and chemical interference caused by complex samples, analyzed by ETAAS after a single dilution step. The chemical modifier and the selected temperatures for the pyrolysis and atomization steps are critical parameters for the performace of an internal standard and they should be carefully considered.
|
7 |
Estudo da utilização de padrão interno em determinações multielementares por espectrometria de absorção atômica com atomização eletrotérmica e detecção simultânea / Study of the use of internal standard for multielement determinations by electrothermal atomic absorption spectrometry with simultaneous detectionPaulo Rogério Miranda Correia 23 July 2004 (has links)
Um estudo sistemático a respeito da utilização de padrão interno em determinações multielementares por espectrometria de absorção atômica (ETAAS) foi desenvolvido. O objetivo principal do presente trabalho foi verificar a possibilidade de melhorar a precisão e a exatidão dos resultados analíticos, que são obtidos na análise de fluidos biológicos. O pré-tratamento dessas amostras foi simplificado e reduzido a uma única etapa de diluição com surfactante (Triton X-100) e ácido (HNO3). Conseqüentemente, a complexidade da solução diluída de amostra, a ser introduzida no tubo de grafite, apresenta uma elevada quantidade de concomitantes que podem provocar interferências químicas. A seleção preliminar dos elementos a serem testados como padrão interno considerou a semelhança de parâmetros físico-químicos relacionados com o processo de atomização. Desta forma, Ag, Bi, In e Tl foram testados como padrão interno para a determinação simultânea de Cd/Pb em sangue e urina, enquanto Bi, Ge, In, Sb, Sn e Te foram os elementos selecionados para a determinação de Mn/Ni/Se em soro sangüíneo. A melhoria da qualidade dos resultados analíticos obtidos na determinação simultânea de Cd e Pb em sangue foi observada quando Ag foi utilizada como padrão interno, na presença de NH4H2PO4 como modificador químico. Verificou-se uma melhoria na exatidão dos resultados obtidos para Cd e Pb, após a correção com padrão interno. Por outro lado, os resultados obtidos na análise de urina não foram corrigidos por nenhum dos elementos testados. Os melhores resultados para a determinação simultânea de Mn, Ni e Se foram obtidos com a utilização de Bi, Sn e Te como padrão interno. Entretanto, verificou-se que a correção de todos os resultados não seria viável com o uso de um único padrão interno. O melhor desempenho nos testes realizados na presença de soro sangüíneo foi obtido com Bi, que melhorou discretamente a precisão dos resultados obtidos para Se. Desta forma, a padronização interna visando a determinação simultânea de Mn, Ni e Se não foi eficiente. A padronização interna em ETAAS, com a finalidade de melhorar a precisão e a exatidão dos resultados analíticos, é uma estratégia tão complexa, quanto os efeitos interferentes que se pretende corrigir: são necessários mais estudos para compreender melhor como a utilização de uma condição de compromisso afeta os processos de atomização, bem como mais informações a respeito das interferências físicas e químicas causadas por amostras complexas, analisadas por ETAAS após uma simples etapa de diluição. Deve-se considerar com especial atenção o modificador químico e as temperaturas das etapas de pirólise e de atomização empregadas, que são parâmetros críticos para o desempenho de um elemento como padrão interno. / A systematic study involving the use of internal standard for multielement determinations by electrothermal atomic absorption spectrometry was developed. The main objective of this work was evaluate the possibility of improving precision and accuracy of the analytical results for biological fluids. The sample pre-treatment was reduced to a single dilution step with surfactant (Triton X-100) and acid (HNO3), increasing the amount of concomitant introduced into the atomizer. The preliminary selection of the elements to be tested as internal standard considered the resemblance of physico-chemical parameters related with the atomization process. Thus, Ag, Bi, In and Tl were tested as internal standard for the simultaneous determination of Cd/Pb in blood and urine, and Bi, Ge, In, Sb, Sn and Te were the selected elements for the determination of Mn/Ni/Se in blood serum. The correction of the results obtained for the simultaneous determination of Cd and Pb in blood was achieved when Ag was used as internal standard, in presence of NH4H2PO4 as chemical modifier. An improvement for the accuracy of the results was observed for both analytes after their correction with the internal standard. On the other hand, the results obtained for the urine analysis were not corrected by using the tested elements. The best results for the simultaneous determination of Mn, Ni and Se were observed when Bi, Sn and Te were used as internal standard. However, the correction for the results for all analytes was not possible by using only one internal standard. The best performance in presence of the serum was obtained for Bi, which improves slightly the precision for the Se results. Thus, the internal standardization for the simultaneous determination of Mn, Ni and Se was not efficient. The internal standardization in ETAAS, aiming the improvement of precision and accuracy of the analytical results, is a strategy as complex as the interference effects to be corrected: more studies are required in order to better understand how the adoption of a compromised condition disturbs the atomization processes, as well as to get more information about the physical and chemical interference caused by complex samples, analyzed by ETAAS after a single dilution step. The chemical modifier and the selected temperatures for the pyrolysis and atomization steps are critical parameters for the performace of an internal standard and they should be carefully considered.
|