Spelling suggestions: "subject:"instrumentação nuclear"" "subject:"lnstrumentação nuclear""
1 |
Utilização da citometria de fluxo para avaliação dos níveis de expressão da proteína p53 em linfócitos do sangue periférico humano irradiados in vitroCAVALCANTI, Mariana Brayner January 2005 (has links)
Made available in DSpace on 2014-06-12T23:16:52Z (GMT). No. of bitstreams: 2
arquivo9077_1.pdf: 1473500 bytes, checksum: 1077fd8671cb43d4cbea383cc4101999 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2005 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A radiação ionizante (RI) pode causar diferentes tipos de danos no DNA, induzindo o aumento da expressão de diversas proteínas fundamentais no processo de reparação celular. Dentre essas proteínas, a proteína p53 é responsável pela conservação da integridade do genoma. Os danos resultantes da interação de agentes físico-químicos com a molécula de DNA podem ocasionar o aumento da concentração e da vida média desta proteína. A correlação entre o aumento dos níveis de expressão da p53 e o nível de irradiação pode constituir um método eficaz em casos de investigações de exposições à RI. Neste sentido, esta pesquisa teve como objetivo a avaliação de um protocolo para a análise dos níveis de expressão da proteína p53 em linfócitos do sangue periférico humano, após irradiação in vitro, utilizando a técnica de citometria de fluxo (CF). Para a quantificação dos níveis de expressão protéica, amostras de sangue periférico de indivíduos sadios foram irradiadas in vitro, com doses conhecidas. Em seguida, os linfócitos foram separados e re-suspensos em meio de cultura celular, onde permaneceram em estufa por um período de 5 horas. Após este período, a quantificação das células positivamente marcadas para a proteína p53 foi realizada pela CF. A partir do protocolo estabelecido nesta pesquisa, foi possível detectar um aumento dos níveis de expressão da proteína p53 para doses acima de 0,5 Gy, sugerindo o emprego da quantificação da p53 pela citometria de fluxo, como biomarcador em casos de suspeita de exposição aguda à RI
|
2 |
Transformando o 152Eu em um Padrão de Calibração de Eficiência para Deteção de GamasCastro, Ruy Morgado de 16 December 2003 (has links)
Neste trabalho foram desenvolvidas as etapas necessárias para transformar a fonte policromática de 152Eu, t1/2 = 13,525(14) anos, em um padrão de calibração de intensidade gama para detetores de HPGe. Foram colocados, por meio de medições de espectroscopia <span style='font-family: Symbol'>g-g do decaimento do 152Eu, 4 níveis no esquema do 152Sm, dos quais 1 novo, e 36 transições, sendo 25 no 152Sm e 11 no 152Gd, das quais 23 foram observadas pela primeira vez. O conjunto dos efeitos secundários de deteção e sua influência sobre as áreas dos picos foram modelados e validados experimentalmente. As áreas dos picos foram descritas a partir das eficiências de deteção e dos parâmetros de decaimento: razões de ramificação, frações de alimentação beta, multipolaridades das transições e coeficientes de conversão interna. As áreas foram ajustadas aos valores experimentais, obtidos em medições de espectroscopia gama simples, fornecendo estimativas para razões de ramificação e frações de alimentação beta dos esquemas de níveis do 152Sm e do 152Gd, de onde foram obtidas as intensidades e correlações estatísticas das transições gama mais intensas que seguem o decaimento do 152Eu. / The steps needed to transform the polychromatic 152Eu, t1/2 = 13,525(14) y, <span style='font-family: Symbol'>g-ray source into a standard for efficiency calibration of HPGe detectors have been developed. Through <span style='font-family: Symbol'>g-g coincidence measurements of the 152Eu decay, 4 levels were placed in the 152Sm scheme, one new, and 36 transitions, 25 in the 152Sm and 11 in 152Gd, where 23 were observed for the first time. The influence of secondary detection effects in the peak areas were evaluated and the corresponding models have been experimentaly checked. Peak-area formulas have been derived from the efficiencies and decay parameters: branching ratios, beta feeding fractions, transition multipolarities and internal conversion coefficients. The experimental data from the $gamma$-ray singles spectrum were fitted by the Least-Squares Method, providing estimates for the branching ratios and beta feeding fractions for the level schemes of 152Sm and 152Gd, allowing the calculation of the intensities and statistical correlations of the most intense gamma transitions following the 152Eu decay.
|
3 |
Transformando o 152Eu em um Padrão de Calibração de Eficiência para Deteção de GamasRuy Morgado de Castro 16 December 2003 (has links)
Neste trabalho foram desenvolvidas as etapas necessárias para transformar a fonte policromática de 152Eu, t1/2 = 13,525(14) anos, em um padrão de calibração de intensidade gama para detetores de HPGe. Foram colocados, por meio de medições de espectroscopia <span style='font-family: Symbol'>g-g do decaimento do 152Eu, 4 níveis no esquema do 152Sm, dos quais 1 novo, e 36 transições, sendo 25 no 152Sm e 11 no 152Gd, das quais 23 foram observadas pela primeira vez. O conjunto dos efeitos secundários de deteção e sua influência sobre as áreas dos picos foram modelados e validados experimentalmente. As áreas dos picos foram descritas a partir das eficiências de deteção e dos parâmetros de decaimento: razões de ramificação, frações de alimentação beta, multipolaridades das transições e coeficientes de conversão interna. As áreas foram ajustadas aos valores experimentais, obtidos em medições de espectroscopia gama simples, fornecendo estimativas para razões de ramificação e frações de alimentação beta dos esquemas de níveis do 152Sm e do 152Gd, de onde foram obtidas as intensidades e correlações estatísticas das transições gama mais intensas que seguem o decaimento do 152Eu. / The steps needed to transform the polychromatic 152Eu, t1/2 = 13,525(14) y, <span style='font-family: Symbol'>g-ray source into a standard for efficiency calibration of HPGe detectors have been developed. Through <span style='font-family: Symbol'>g-g coincidence measurements of the 152Eu decay, 4 levels were placed in the 152Sm scheme, one new, and 36 transitions, 25 in the 152Sm and 11 in 152Gd, where 23 were observed for the first time. The influence of secondary detection effects in the peak areas were evaluated and the corresponding models have been experimentaly checked. Peak-area formulas have been derived from the efficiencies and decay parameters: branching ratios, beta feeding fractions, transition multipolarities and internal conversion coefficients. The experimental data from the $gamma$-ray singles spectrum were fitted by the Least-Squares Method, providing estimates for the branching ratios and beta feeding fractions for the level schemes of 152Sm and 152Gd, allowing the calculation of the intensities and statistical correlations of the most intense gamma transitions following the 152Eu decay.
|
4 |
Utilização de redes neurais artificiais para identificação de energia em campos fotônicos com materiais termoluminescentesRamos da Silveira, Renata January 2006 (has links)
Made available in DSpace on 2014-06-12T23:17:03Z (GMT). No. of bitstreams: 2
arquivo9110_1.pdf: 1563256 bytes, checksum: 28869f7530bc27f7721347b575f57574 (MD5)
license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5)
Previous issue date: 2006 / A alta qualidade de um serviço de monitoração individual é de fundamental importância para
a segurança dos trabalhadores que exercem suas atividades em ambientes controlados e
dependem de avaliações precisas das doses que receberam e podem vir a receber durante o
desempenho das suas atividades profissionais.
O investimento em pesquisas que possibilitem o aperfeiçoamento da qualidade da resposta
fornecida com o sistema dosimétrico utilizado é de fundamental importância. Para isto, o Laboratório
de Dosimetria Temoluminescente do Centro Regional de Ciências Nucleares, Instituto da Comissão
Nacional de Energia Nuclear, possui um programa que visa pesquisar, testar e implementar novos
processos que resultem na melhoria da qualidade de seus serviços.
Objetivando identificar os espectros em energia para campos fotônicos, foi investigada neste
trabalho a aplicabilidade da inteligência artificial, através do uso de uma rede neural multicamadas,
como ferramenta de classificação de padrões em energia, associada a um sistema dosimétrico
termoluminescente (TLD-700 e TLD-600).
Os dosímetros foram expostos inicialmente a diversas energias médias conhecidas, entre
16 keV e 1,2 MeV, para o intervalo de doses de 0,5 a 10 mSv, com o propósito de gerar um conjunto de dados de treinamento para a rede neural. Posteriormente, um novo conjunto de
dosímetros irradiados em energias desconhecidas para a rede neural, foi utilizado para testes.
A metodologia empregada neste trabalho se mostrou adequada à aplicação na classificação
de energias. As melhores respostas foram obtidas para irradiações com altas doses, com 100% de
acerto, para 10 mSv
|
5 |
Efeitos do colimador na qualidade de imagem em tomografia industrial de terceira geração / Collimator effects on image quality in industrial tomography third generationCarvalho, Diego Vergaças de Sousa 08 May 2014 (has links)
O estudo do efeito da colimação nos detectores de radiação sobre a qualidade de imagem do tomógrafo industrial de terceira geração desenvolvido no IPEN/CNEN-SP é descrito neste trabalho. Três conjuntos de colimadores de chumbo foram projetados e confeccionados, sendo um com janelas retangulares de 2 x 5 x 50 mm e outro com 4 x 10 x 50 mm (largura x comprimento x profundidade) e um terceiro com orifício circular de 5 mm de diâmetro x 40 mm de profundidade. Os colimadores foram projetados para poderem ser facilmente substituídos entre si nos detectores de radiação. Paralelamente, foram confeccionados e utilizadas a eletrônica associada, constituída de analisadores de sinais tipo multicanal de 8 bits contendo a unidade de alta tensão e o amplificador. Dentre as vantagens deste sistema destaca-se a sua capacidade de análise multicanal rápida e possuir uma eletrônica mais simples. Valores de resolução energética comparável com a da literatura foram encontrados utilizando a eletrônica desenvolvida acoplada ao detector de radiação de NaI(Tl). Os efeitos dos colimadores foram avaliados pelas medidas tomográficas em um fantom de polimetilmetacrilato contendo componentes multifásicos estáticos (ferro, alumínio e ar). Fontes de radiação com energias de das fontes de 75Se (97 keV, 121 keV, 136 keV, 265 keV, 279 keV e 400 keV), de 137Cs (662 keV) e de 192Ir (317 keV, 468 keV e 602 keV) observou-se que a melhor imagem do fantom foi obtida com os colimadores de janelas retangulares (fendas) de 2 x 5 x 50 mm. Na avaliação dinâmica da formação de bolhas em coluna simuladora de processos industriais, a melhor imagem foi obtida com a fonte de 192Ir. / The study of the effect of collimation in radiation detectors on the image quality of the third-generation industrial CT scanner developed at IPEN / CNEN-SP is described in this work. Three sets of lead collimators were designed and manufactured, one with rectangular windows of 2 x 5 x 50 mm and the other with 4 x 10 x 50 mm (width x length x deep) and a third circular hole of 5 mm diameter x 40 mm deep. The collimators were designed to be easily interchanged in radiation detectors. In parallel, were prepared and used the associated electronics, consisting of multi-channel signal analyzers type of 8 bits containing the high voltage unit and the amplifier. Among the advantages of this system stands out for its ability to fast multichannel analysis and possess a simpler electronics. Values in energy resolution comparable with the literature were found using the developed electronics coupled to the radiation detector of NaI (Tl). The effects of collimators were evaluated by tomographic measurements in a multiphase fantom polymethyl methacrylate containing static components (iron, aluminum and air). Radiation sources with energies of the sources of 75Se (97 keV, 121 keV, 136 keV, 265 keV, 279 keV and 400 keV), 137Cs (662 keV) and 192Ir (317 keV, 468 keV and 602 keV) observed that the best image was obtained fantom collimators with rectangular windows (slits) 2 x 5 x 50 mm. In the dynamic evaluation of formation of bubbles column in a simulated industrial processes the best image at was obtained with the 192Ir source.
|
6 |
Efeitos do colimador na qualidade de imagem em tomografia industrial de terceira geração / Collimator effects on image quality in industrial tomography third generationDiego Vergaças de Sousa Carvalho 08 May 2014 (has links)
O estudo do efeito da colimação nos detectores de radiação sobre a qualidade de imagem do tomógrafo industrial de terceira geração desenvolvido no IPEN/CNEN-SP é descrito neste trabalho. Três conjuntos de colimadores de chumbo foram projetados e confeccionados, sendo um com janelas retangulares de 2 x 5 x 50 mm e outro com 4 x 10 x 50 mm (largura x comprimento x profundidade) e um terceiro com orifício circular de 5 mm de diâmetro x 40 mm de profundidade. Os colimadores foram projetados para poderem ser facilmente substituídos entre si nos detectores de radiação. Paralelamente, foram confeccionados e utilizadas a eletrônica associada, constituída de analisadores de sinais tipo multicanal de 8 bits contendo a unidade de alta tensão e o amplificador. Dentre as vantagens deste sistema destaca-se a sua capacidade de análise multicanal rápida e possuir uma eletrônica mais simples. Valores de resolução energética comparável com a da literatura foram encontrados utilizando a eletrônica desenvolvida acoplada ao detector de radiação de NaI(Tl). Os efeitos dos colimadores foram avaliados pelas medidas tomográficas em um fantom de polimetilmetacrilato contendo componentes multifásicos estáticos (ferro, alumínio e ar). Fontes de radiação com energias de das fontes de 75Se (97 keV, 121 keV, 136 keV, 265 keV, 279 keV e 400 keV), de 137Cs (662 keV) e de 192Ir (317 keV, 468 keV e 602 keV) observou-se que a melhor imagem do fantom foi obtida com os colimadores de janelas retangulares (fendas) de 2 x 5 x 50 mm. Na avaliação dinâmica da formação de bolhas em coluna simuladora de processos industriais, a melhor imagem foi obtida com a fonte de 192Ir. / The study of the effect of collimation in radiation detectors on the image quality of the third-generation industrial CT scanner developed at IPEN / CNEN-SP is described in this work. Three sets of lead collimators were designed and manufactured, one with rectangular windows of 2 x 5 x 50 mm and the other with 4 x 10 x 50 mm (width x length x deep) and a third circular hole of 5 mm diameter x 40 mm deep. The collimators were designed to be easily interchanged in radiation detectors. In parallel, were prepared and used the associated electronics, consisting of multi-channel signal analyzers type of 8 bits containing the high voltage unit and the amplifier. Among the advantages of this system stands out for its ability to fast multichannel analysis and possess a simpler electronics. Values in energy resolution comparable with the literature were found using the developed electronics coupled to the radiation detector of NaI (Tl). The effects of collimators were evaluated by tomographic measurements in a multiphase fantom polymethyl methacrylate containing static components (iron, aluminum and air). Radiation sources with energies of the sources of 75Se (97 keV, 121 keV, 136 keV, 265 keV, 279 keV and 400 keV), 137Cs (662 keV) and 192Ir (317 keV, 468 keV and 602 keV) observed that the best image was obtained fantom collimators with rectangular windows (slits) 2 x 5 x 50 mm. In the dynamic evaluation of formation of bubbles column in a simulated industrial processes the best image at was obtained with the 192Ir source.
|
7 |
UM ESPECTROMETRO \"MINI-ORANGE\" PARA ELECTRONS / A mini-orange spectrometer for electronsSilva, Nelson Canzian da 04 May 1990 (has links)
Foi projetado e construído um espectrômetro Mini-Orange (MO) para eléctrons, utilizando imãs planos permanentes e um detector de barreira de superfície. Foram determinadas as funções de transmissão de diferentes configurações do sistema, para energias entre 200-1100 keV. Foi desenvolvido um modelo matemático do sistema, a partir de solução analítica para o campo de um imã plano e da integração numérica da equação de movimento dos eléctrons no campo de MO. As funções de transmissão assim obtidas foram comparadas aos resultados experimentais e mostraram um bom acordo para energias baixas e intermediárias. / A Mini-Orange spectrometer for electrons was designed and built, using plane permanent magnets and a surface barrier detector. Transmission functions were obtained for various system configurations and for energies between 200-1100 keV. A mathematical model of the system was developed, using the analytical solution for the field of a plane magnet and the numerical integration of the equation of motion of the electrons in the MO magnetic field. The calculated transmission functions were compared to the experimental data, showing a good agreement for low and intermediate energies.
|
8 |
Implementação e análise de medidas de reações por meio de coincidências -partícula / Implementatios and analyses of measurements in reaction using Y-particle coincidentsZagatto, Vinicius Antonio Bocaline 14 October 2011 (has links)
A reação 18O+110Pd foi estudada utilizando o espectrômetro Y Saci-Perere do laboratório do acelerador Pelletron (LAFN-IFUSP-DFN) numa faixa de energia de 2; 5 a 3; 3 MeV por núcleon. O objetivo foi o estudo do mecanismo de reações nucleares por meio de coincidências Y-partícula, implantando essa técnica e vericando como os efeitos de integração da energia perdida no alvo, integração no ângulo sólido do detector de partículas, tamanho finito do detector HPGe e o efeito de decaimento em vácuo afetavam as medidas. Observa-se que as correções dos dados devidas a esses efeitos são pequenas e bem controladas, com exceção do efeito de decaimento em vácuo que necessita de um estudo mais aprofundado. Concluiu-se que a distribuiçao angular do espalhamento elástico para o primeiro estado excitado do 110Pd pode ser razoavelmente bem representada utilizando-se o Potencial de São Paulo (PSP) na forma U(R) = (0; 6 + 0; 6i)V SP EL (R).No entanto a descrição da transferência para o primeiro estado excitado do 112Pd não foi tão bem sucedida. / The 18O+110Pd reaction has been studied in the range from 2; 5 to 3; 3 MeV per nucleon using the Saci-Perere y-ray spectrometer at the Pelletron accelerator Laboratory (LAFN-IFUSP-DFN). The objective was the study of nuclear reaction mechanisms by the use of y-particle coincidence, establishing this technique, and verifying how the eects of energy loss in the target, the nite solid angle of the particle detector, the nite size of HPGe detector, and the vacuum de-alignment aect the measurements. It was observed that the corrections to the data due to these eects are small and well controlled, with exception of the vacuum de-alignment, which has to be studied more deeply. It was concluded that the inelastic scattering to the rst excited state of 110Pd can be reasonably well described using the São Paulo Potencial (PSP) in the form U(R) = (0; 6 + 0; 6i)V SP LE . However the description of the transfer to the rst excited state of 112Pd was not so well succeeded.
|
9 |
Implementação e análise de medidas de reações por meio de coincidências -partícula / Implementatios and analyses of measurements in reaction using Y-particle coincidentsVinicius Antonio Bocaline Zagatto 14 October 2011 (has links)
A reação 18O+110Pd foi estudada utilizando o espectrômetro Y Saci-Perere do laboratório do acelerador Pelletron (LAFN-IFUSP-DFN) numa faixa de energia de 2; 5 a 3; 3 MeV por núcleon. O objetivo foi o estudo do mecanismo de reações nucleares por meio de coincidências Y-partícula, implantando essa técnica e vericando como os efeitos de integração da energia perdida no alvo, integração no ângulo sólido do detector de partículas, tamanho finito do detector HPGe e o efeito de decaimento em vácuo afetavam as medidas. Observa-se que as correções dos dados devidas a esses efeitos são pequenas e bem controladas, com exceção do efeito de decaimento em vácuo que necessita de um estudo mais aprofundado. Concluiu-se que a distribuiçao angular do espalhamento elástico para o primeiro estado excitado do 110Pd pode ser razoavelmente bem representada utilizando-se o Potencial de São Paulo (PSP) na forma U(R) = (0; 6 + 0; 6i)V SP EL (R).No entanto a descrição da transferência para o primeiro estado excitado do 112Pd não foi tão bem sucedida. / The 18O+110Pd reaction has been studied in the range from 2; 5 to 3; 3 MeV per nucleon using the Saci-Perere y-ray spectrometer at the Pelletron accelerator Laboratory (LAFN-IFUSP-DFN). The objective was the study of nuclear reaction mechanisms by the use of y-particle coincidence, establishing this technique, and verifying how the eects of energy loss in the target, the nite solid angle of the particle detector, the nite size of HPGe detector, and the vacuum de-alignment aect the measurements. It was observed that the corrections to the data due to these eects are small and well controlled, with exception of the vacuum de-alignment, which has to be studied more deeply. It was concluded that the inelastic scattering to the rst excited state of 110Pd can be reasonably well described using the São Paulo Potencial (PSP) in the form U(R) = (0; 6 + 0; 6i)V SP LE . However the description of the transfer to the rst excited state of 112Pd was not so well succeeded.
|
10 |
UM ESPECTROMETRO \"MINI-ORANGE\" PARA ELECTRONS / A mini-orange spectrometer for electronsNelson Canzian da Silva 04 May 1990 (has links)
Foi projetado e construído um espectrômetro Mini-Orange (MO) para eléctrons, utilizando imãs planos permanentes e um detector de barreira de superfície. Foram determinadas as funções de transmissão de diferentes configurações do sistema, para energias entre 200-1100 keV. Foi desenvolvido um modelo matemático do sistema, a partir de solução analítica para o campo de um imã plano e da integração numérica da equação de movimento dos eléctrons no campo de MO. As funções de transmissão assim obtidas foram comparadas aos resultados experimentais e mostraram um bom acordo para energias baixas e intermediárias. / A Mini-Orange spectrometer for electrons was designed and built, using plane permanent magnets and a surface barrier detector. Transmission functions were obtained for various system configurations and for energies between 200-1100 keV. A mathematical model of the system was developed, using the analytical solution for the field of a plane magnet and the numerical integration of the equation of motion of the electrons in the MO magnetic field. The calculated transmission functions were compared to the experimental data, showing a good agreement for low and intermediate energies.
|
Page generated in 0.1222 seconds