• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 27
  • Tagged with
  • 27
  • 27
  • 23
  • 19
  • 15
  • 15
  • 13
  • 13
  • 11
  • 9
  • 8
  • 7
  • 7
  • 6
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Avaliação histológica da limpeza dos canais radiculares promovida por diferentes métodos de irrigação e análise tomográfica da área apical no comprimento de trabalho / Histologic evaluation of root canal cleaning promoted by different irrigation methods and tomographic analysis of the apical area in the working length

Seixas, Fabio Heredia 19 April 2011 (has links)
O objetivo deste estudo foi avaliar in vitro a limpeza das paredes dos canais radiculares pelo método histológico e a determinação tomográfica da área apical antes e após a instrumentação de dentes portadores de achatamento mésio-distal, submetidos a diferentes sistemas de irrigação e preparados pela técnica rotatória mecanizada com instrumentos de níquel-titânio. Para tanto, foram utilizados 42 dentes incisivos inferiores humanos uniradiculares de estoque que tiveram suas áreas anatômicas apicais escaneados pelo tomógrafo computadorizado I-CAT cone beam e analisados por meio do software I-CATvision®. Posteriormente a realização da cirurgia de acesso e preparo cervical, foi determinado o instrumento apical inicial e comprimento de trabalho dos dentes pelo método clínico. Cada espécime foi instrumentado mecanicamente pela técnica Free Tip Preparation até três, quatro e cinco instrumentos acima do inicial, de acordo com o grupo experimental. A irrigação foi feita pelos métodos convencional e hidrodinâmico, com hipoclorito de sódio a 2,5% entre cada troca de instrumento e irrigação final com solução de EDTA a 17%. A seguir, os dentes foram submetidos à nova tomada tomográfica para a visualização do diâmetro cirúrgico. As mensurações obtidas clinicamente e por meio do tomógrafo revelaram não haver diferenças significantes entre os diâmetros anatômicos através dos dois métodos (p>0,05), porém observaram-se diferenças entre os diâmetros cirúrgicos (p<0,001). Posteriormente, as amostras foram submetidas ao processo histológico com coloração H.E. e seus terços apicais analisados por microscópio óptico com aumento de 40X. As imagens foram capturadas digitalmente pelo software Movie Maker® e os resultados da limpeza foram submetidos à análise estatística (two-way ANOVA com pós-teste de Bonferroni). Os resultados não demonstraram diferença entre os tipos de irrigação testados (p=0,78), mas, revelou haver diferenças entre os grupos no que tange à limpeza dos canais radiculares dos diferentes diâmetros apicais de instrumentação (p<0,001). O preparo biomecânico com quatro instrumentos acima do instrumento apical inicial determinou uma área de atuação significantemente superior ao mesmo preparo com apenas três instrumentos, produzindo paredes dentinárias mais limpas. O preparo com cinco instrumentos acima do instrumento apical inicial, entretanto, não foi capaz de melhorar a limpeza do terço apical quando comparado ao preparo produzido por quatro limas além do instrumento apical inicial (p>0,05). Foram observados predominância do formato elíptico das paredes dos canais radiculares no comprimento de trabalho das amostras estudadas. / The aim of this study was to evaluate in vitro the cleanliness of root canal walls and the precision of tomographic analysis to determine the apical area before and after instrumentation of teeth with mesio-distal flattening, submitted to different irrigations systems and prepared by rotary nickel-titanium instruments. Forty-two human, single-canal lower incisors had their apical area evaluated either clinically or by tomography. Each specimen was instrumented using the Free Tip Preparation technique up to three, four or five instruments above the initial, according to the experimental group. Irrigation was performed by conventional or hydrodynamic means, using 2,5 % sodium hypochlorite after each instrument and a final flush of 17 % EDTA. The samples were submitted to a new tomographic scan and prepared for observation under a light microscope. Images were digitally obtained, analyzed and the results were submitted to statistical analysis (two-way ANOVA complemented by Bonferronis posttest). The readings made clinically or by the tomography revealed no differences between the anatomical diameters (p>0.05), but the surgical were different (p<0.001). There were no differences between irrigation methods (p=0.78). The results regarding the action of the instrument on the root canal walls showed that irrigation did not present a significant impact on the action of the instrument in the canal (p= 0,11); however, the statistical analysis revealed differences between instrumentation techniques (p<0.001). Instrumentation with four instruments above the initial file determined a significant increase in the actuation area when compared to preparation with three instruments. Preparation with five files above the initial did not result in an improved cleanliness (p>0,05). It can be concluded that the tomography shows discrepancies when compared to clinical determination of the anatomical diameter. Regarding the cleanliness obtained by the different irrigation methods, no differences were observed between groups. Preparation with four instruments showed a significant superior acting area when compared to only three instruments above the initial file. The same could not be observed when five instruments were used.
22

Efetividade de diferentes sistemas de preparo do canal radicular na eliminação de Enterococcus faecalis / Effectiveness of diferente root canal preparation systems against Enterococcus faecalis

Mario Francisco de Pasquali Leonardo 08 August 2012 (has links)
O objetivo deste estudo consiste em avaliar a efetividade de diferentes sistemas empregados no preparo biomecânico, dentre eles: Self-adjusting file (SAF), TiLOS Anatomic Endodontic Technology System (TiLOS) e Mtwo sobre a eliminação de Enterococcus faecalis cultivados em canais radiculares. Para isso, foram selecionados 47 prés-molares inferiores humanos, os quais foram contaminados por Enterococcus faecalis (ATCC 29212) durante 21 dias e divididos em três grupos: GI - SAF com irrigação contínua; GII - EndoEze Tilos e irrigação com auxílio de agulhas NaviTip; GIII - MTwo e irrigação com NaviTip a cada troca de instrumento. A irrigação foi realizada com solução de NaOCl a 2,5%. Coletas bacterianas foram realizadas em três tempos experimentais: coleta da contaminação (S1), posterior ao preparo dos canais radiculares (S2) e após sete dias do preparo biomecânico (S3). Os dados em UFC foram submetidos aos testes ANOVA e Tukey ou Kruskal-Wallis e Dunn com P<0.05. Na análise dos resultados, foi observada redução de E.faecalis após preparo (P < .05) em todos os grupos, sem diferença significante entre os grupos (P > .05). A coleta final demonstrou aumento bacteriano similar em todos os grupos, esclarecendo a viabilidade das bactérias incubadas. Dessa forma, conclui-se que o preparo dos canais radiculares realizado com SAF, EndoEze Tilos e Mtwo contribuem na desinfecção do canal radicular, sem, todavia, eliminar o E. faecalis do sistema de canais radiculares. / The aim of this study was to evaluate the effectiveness of different chemo-mechanical systems for root canal preparation Self-adjusting File (SAF), TiLOS Anatomic Endodontic Technology System (TiLOS), and Mtwo against Enterococcus faecalis in the canal. Forty seven human mandibular bicuspids were contaminated with E. faecalis (ATCC 29212) for 21 days and divided into groups according to preparation methodÇ SAF group with continuous irrigationç TiLOS;Endo-Eze group and irrigation with a NaviTip needle Mtwo group and irrigation eith NaviTip. The irrigant used was 2.5% NaOCl. Bacterial harvests were performed after the contamination period (initial harvest), immediately post-preparation, and seven days after chemo-mechanical preparation. Data were expressed as CFU and subjected to ANOVA and Tukey or Kruskal-Wallis and Dunn tests at P < 0.05. Reduction in E.faecalis was observed after preparation (P< .05), with no significant differences between the groups (P> .05). The final harvest demonstrated statistically similar increase in the bacterial counts in all groups. Root canal preparation using SAF, TiLOS;Endo-Eze, and Mtwo systems contribute for the disinfection of the root
23

Avaliação histológica da limpeza dos canais radiculares promovida por diferentes métodos de irrigação e análise tomográfica da área apical no comprimento de trabalho / Histologic evaluation of root canal cleaning promoted by different irrigation methods and tomographic analysis of the apical area in the working length

Fabio Heredia Seixas 19 April 2011 (has links)
O objetivo deste estudo foi avaliar in vitro a limpeza das paredes dos canais radiculares pelo método histológico e a determinação tomográfica da área apical antes e após a instrumentação de dentes portadores de achatamento mésio-distal, submetidos a diferentes sistemas de irrigação e preparados pela técnica rotatória mecanizada com instrumentos de níquel-titânio. Para tanto, foram utilizados 42 dentes incisivos inferiores humanos uniradiculares de estoque que tiveram suas áreas anatômicas apicais escaneados pelo tomógrafo computadorizado I-CAT cone beam e analisados por meio do software I-CATvision®. Posteriormente a realização da cirurgia de acesso e preparo cervical, foi determinado o instrumento apical inicial e comprimento de trabalho dos dentes pelo método clínico. Cada espécime foi instrumentado mecanicamente pela técnica Free Tip Preparation até três, quatro e cinco instrumentos acima do inicial, de acordo com o grupo experimental. A irrigação foi feita pelos métodos convencional e hidrodinâmico, com hipoclorito de sódio a 2,5% entre cada troca de instrumento e irrigação final com solução de EDTA a 17%. A seguir, os dentes foram submetidos à nova tomada tomográfica para a visualização do diâmetro cirúrgico. As mensurações obtidas clinicamente e por meio do tomógrafo revelaram não haver diferenças significantes entre os diâmetros anatômicos através dos dois métodos (p>0,05), porém observaram-se diferenças entre os diâmetros cirúrgicos (p<0,001). Posteriormente, as amostras foram submetidas ao processo histológico com coloração H.E. e seus terços apicais analisados por microscópio óptico com aumento de 40X. As imagens foram capturadas digitalmente pelo software Movie Maker® e os resultados da limpeza foram submetidos à análise estatística (two-way ANOVA com pós-teste de Bonferroni). Os resultados não demonstraram diferença entre os tipos de irrigação testados (p=0,78), mas, revelou haver diferenças entre os grupos no que tange à limpeza dos canais radiculares dos diferentes diâmetros apicais de instrumentação (p<0,001). O preparo biomecânico com quatro instrumentos acima do instrumento apical inicial determinou uma área de atuação significantemente superior ao mesmo preparo com apenas três instrumentos, produzindo paredes dentinárias mais limpas. O preparo com cinco instrumentos acima do instrumento apical inicial, entretanto, não foi capaz de melhorar a limpeza do terço apical quando comparado ao preparo produzido por quatro limas além do instrumento apical inicial (p>0,05). Foram observados predominância do formato elíptico das paredes dos canais radiculares no comprimento de trabalho das amostras estudadas. / The aim of this study was to evaluate in vitro the cleanliness of root canal walls and the precision of tomographic analysis to determine the apical area before and after instrumentation of teeth with mesio-distal flattening, submitted to different irrigations systems and prepared by rotary nickel-titanium instruments. Forty-two human, single-canal lower incisors had their apical area evaluated either clinically or by tomography. Each specimen was instrumented using the Free Tip Preparation technique up to three, four or five instruments above the initial, according to the experimental group. Irrigation was performed by conventional or hydrodynamic means, using 2,5 % sodium hypochlorite after each instrument and a final flush of 17 % EDTA. The samples were submitted to a new tomographic scan and prepared for observation under a light microscope. Images were digitally obtained, analyzed and the results were submitted to statistical analysis (two-way ANOVA complemented by Bonferronis posttest). The readings made clinically or by the tomography revealed no differences between the anatomical diameters (p>0.05), but the surgical were different (p<0.001). There were no differences between irrigation methods (p=0.78). The results regarding the action of the instrument on the root canal walls showed that irrigation did not present a significant impact on the action of the instrument in the canal (p= 0,11); however, the statistical analysis revealed differences between instrumentation techniques (p<0.001). Instrumentation with four instruments above the initial file determined a significant increase in the actuation area when compared to preparation with three instruments. Preparation with five files above the initial did not result in an improved cleanliness (p>0,05). It can be concluded that the tomography shows discrepancies when compared to clinical determination of the anatomical diameter. Regarding the cleanliness obtained by the different irrigation methods, no differences were observed between groups. Preparation with four instruments showed a significant superior acting area when compared to only three instruments above the initial file. The same could not be observed when five instruments were used.
24

Avaliação do preparo de canais radiculares com instrumentos rotatórios torcidos e usinados, por meio de cortes transversais e da microtomografia computadorizada / Evaluation of root canal preparation with rotary instruments twisted and ground by means of cross sections and microcomputed tomography

Laila Gonzales Freire 02 August 2010 (has links)
O preparo químico-cirúrgico é uma das etapas mais importantes do tratamento endodôntico, pois promove a desinfecção do sistema de canais radiculares através da limpeza e da modelagem. Realizar o preparo de canais curvos é um grande desafio, devido à ocorrência freqüente de acidentes operatórios como o transporte do canal. A introdução de instrumentos fabricados em ligas de níquel-titânio (NiTi) contribuiu consideravelmente para a melhora na qualidade da instrumentação dos canais. Os diferentes sistemas rotatórios que são apresentados continuamente ao profissional devem ser estudados com detalhes, pois o seu comportamento pode variar de acordo com o desenho de cada instrumento e as suas características de produção. O objetivo deste estudo foi avaliar, ex vivo, a qualidade do preparo de canais curvos realizado pelos sistemas rotatórios Twisted File (TF; Sybron Endo), torcidos, e EndoSequence (ES; Brasseler), usinados, quanto à habilidade em manter o canal centralizado, analisando a extensão e a direção dos eventuais transportes e o índice de centralização do instrumento (IC), por meio de cortes transversais e da microtomografia computadorizada (CT). Trinta molares inferiores foram divididos em dois grupos, e preparados conforme o delineamento de cada método: G1 - Bramante Modificado e G2 - CT. No G1, os dentes foram incluídos em blocos de resina, e seccionados a 2,0, 3,5 e 5,0 mm do ápice radicular. As secções foram fotografadas, e os blocos, remontados, foram submetidos à instrumentação rotatória. No G2, os dentes foram incluídos em material de moldagem e escaneados com um microtomógrafo, antes e após o preparo. As imagens das seções transversais foram reconstruídas e os cortes axiais correspondentes às distâncias de 2,0, 3,5 e 5,0 mm do ápice radicular foram selecionados. Os resultados foram submetidos ao teste estatístico não-paramétrico Mann-Whitney, para comparações duas a duas. Em ambos os grupos, o transporte do canal e o IC para os sistemas TF e ES foram semelhantes, havendo diferença estatística significante apenas no G2, na secção 3,5 mm, quando o sistema TF causou menos transporte do que o sistema ES, obtendo também um melhor IC (p < 0,05). Quando realizada a comparação entre os métodos, independentemente do instrumento utilizado, o transporte do canal foi significantemente menor (0,17 mm) no grupo 2, do que no grupo 1 (0,27 mm) (p < 0,05). A 3,5 e 5,0 mm, o sistema TF promoveu menos transporte no grupo 2 do que no grupo 1 (p < 0,05). Para o sistema ES, diferença estatística foi encontrada a 2,0 mm, aonde o transporte também foi menor no grupo 2 (p < 0,05). Concluiu-se que os sistemas TF e ES se comportaram de modo semelhante quanto ao transporte do canal e ao IC, permitindo o preparo de canais curvos com pouco desvio. Os dois instrumentos apresentaram desvios tanto para o sentido mesial, quanto para o sentido distal. E quando comparados apenas os métodos de avaliação, no método da CT o transporte do canal foi menor do que no método de Bramante Modificado. / The chemomechanical preparation is one of the most important phases of endodontic treatment, because it promotes disinfection of the root canal system by cleaning and shaping. The preparation of curved canals is a major challenge due to the frequent occurrence of operative accidents as the canal transportation. The introduction of instruments of nickel-titanium (NiTi) alloy has contributed considerably to the improvement of canal instrumentation quality. The different rotary systems that are continuously presented to dental professionals should be studied in detail, because their mechanical properties can vary according to the design of each instrument and the manufacture characteristics. The aim of this study was to evaluate, ex vivo, the quality of preparation of curved canals and centering ability of the rotary systems Twisted File (TF) (Sybron Endo), twisted, and EndoSequence (ES) (Brasseler), ground, analyzing the extent and direction of any transportation and the centering ratio of instrument, by cross sections and microcomputed tomography (CT). Thirty lower molars were divided into two groups, and prepared according to the design of each method: G1 Bramante Modified and G2 - CT. In G1, the teeth were embedded in resin blocks and sectioned at 2,0, 3,5 and 5,0 mm from the apex. The sections were photographed and the blocks were reassembled and subjected to rotary instrumentation. In G2, the teeth were embedded in an impression material and scanned with a microtomograph, before and after preparation. The images were reconstructed from the cross sections and the axial sections corresponding to distances of 2,0, 3,5 and 5,0 mm from the apex were selected. The results were submitted to statistical nonparametric test Mann-Whitney. In both groups, the canal transportation and IC for TF and ES systems were similar, with statistical difference only for the 3.5 mm section, while TF system caused less canal transportation than ES system, obtaining also better IC (p <0.05). When compared only the methods, regardless of instrument used, the canal transportation was significantly smaller (0.17 mm) in group 2 than in group 1 (0.27 mm) (p <0.05). At 3.5 and 5.0 mm, TF system promoted less transportation in group 2 than in group 1 (p <0.05). For ES system, statistical difference was found at 2.0 mm, where transportation was also lower in group 2 (p <0.05). It was concluded that the systems TF and ES behaved similarly about the canal transportation and the centering ability, allowing the preparation of curved canals with little deviation. The two instruments showed deviations for both the mesial and distal direction. When comparing only the methods of assessment, at CT the canal transportation was lower than in Bramante Modified method.
25

Avaliação dos preparos de canais radiculares com secção transversal oval longa realizados pelos sistemas XP endo shaper e Mtwo utilizando a microtomografia computadorizada / Evaluation of the preparation of long oval root canals with XP-endo Shaper and Mtwo, systems using micro-computed tomography

Marques, Juliana Lisboa Couto 26 February 2019 (has links)
O tratamento endodôntico tem por finalidade primordial oferecer um ambiente favorável para que o organismo possa proporcionar o reparo dos tecidos periapicais possibilitando ao dente o retorno de suas funções. Uma das principais dificuldades de se lograr tal objetivo reside na complexidade anatômica dos canais radiculares, oferecendo sítios de difícil acesso a instrumentos e substâncias químicas, responsáveis pela promoção desse ambiente. Novos instrumentos mecanizados de NiTi foram desenvolvidos propondo diferentes tratamentos térmicos com a finalidade de melhorar a adaptação a canais ovalados, permitindo tocar o maior número de paredes dos canais radiculares. O sistema XP- endo Shaper (FKG Dentaire, La Chaux-de-Fonds, Suíça), recentemente lançado, possui um design inovador, sendo capaz de reagir a variações de temperatura e adquirir uma forma pré-determinada dentro do canal radicular, na temperatura corpórea, bem como atingir áreas inacessíveis para os instrumentos convencionais, tocando os pontos mais dificeis dos canais ovais. O presente estudo tem por objetivos, avaliar o preparo de canais ovais longos de molares inferiores com o sistema XP- endo Shaper comparando-o com instrumentos do sistema Mtwo, por meio da microtomografia computadorizada (?CT). Foram selecionadas 32 raízes distais de molares inferiores divididos aleatoriamente em 2 grupos de 16, de acordo com o método de instrumentação a ser avaliado: Grupo XP - Instrumentação com XP- endo Shaper e Grupo Mtwo - instrumentação com Mtwo. Após a utilização dos softwares Data Viewer, CTan, CTVol foi possível a visualização e análise tridimensional do canal radicular antes e após os procedimentos de preparo-químico cirúrgico, para a comparação do volume de dentina removida, aumento do volume do canal, aumento da área de superfície do canal, superfícies não preparadas do canal, volume de debris e índice de modelo de estrutura (SMI). Os resultados foram submetidos aos testes Shapiro-Wilk e Mann-Whitney. Demonstrando que não houve uma diferença estatística entre os grupos XP-endo Shaper e Mtwo quanto o volume de dentina removida, aumento do volume do canal, aumento da área de superfície do canal, superfícies não preparadas do canal, volume de debris e SMI. Concluiu-se que nenhum sistema estudado foi capaz de tocar todas as paredes de um canal oval longo e que ambas as técnicas se comportam de maneiras semelhantes quanto a do volume de dentina removida, aumento do volume do canal, aumento da área de superfície do canal, SMI, superfícies não preparadas do canal e volume de debris. / Endodontic treatment has the primary purpose of offering a favorable environment so that the body can provide the repair of the periapical tissues enabling the tooth to return to its functions. One of the main difficulties in achieving this objective is the anatomical complexity of the root canals, offering difficult access to instruments and chemical substances responsible for promoting this environment. New NiTi rotatory instruments were developed by proposing different thermal treatments with the purpose of improving the adaptation to oval root canals, allowing instrumenting the largest number of root canal walls. The newly launched XP-endo Shaper system (FKG Dentaire, La Chaux-de-Fonds, Switzerland) has an innovative design, being able to react to temperature variations and acquire a predetermined shape inside the root canal, at body temperature, as well as reaching areas inaccessible to conventional instruments, instrumenting the hardest points of oval canals. The aim of the present study was to evaluate the preparation of long oval canals of mandibular molars with the XP-endo Shaper system, comparing it with the Mtwo system instruments, using micro-computerized tomography (?CT). 32 distal roots of mandibular molars were randomly divided into 2 groups of 16, according to the instrumentation method to be evaluated: XP Group - Instrumentation with XP-endo Shaper and Mtwo Group - instrumentation with Mtwo. After the use of the CTan, CTVol and Data Viewer softwares, it was possible to visualize and analyze three-dimensionally the root canal, before and after the chemical-surgical procedures, to compare the volume of dentin removed, the increase of volume of the canal, the increase of area of the canal surface, unprepared canal surfaces, volume of debris and structure model index (SMI). Results were submitted to the Shapiro-Wilk and Mann-Whitney statistical tests. It was demonstrated that there was no statistically significant difference between the XP-endo Shaper and Mtwo groups, referring to the volume of dentin removed, increase in canal volume, increase in the surface area of the canal, unprepared surfaces of the canal, volume of debris and SMI. We concluded that no studied system was able to touch all the walls of a long oval canal and that both techniques behave in a similar way as the volume of dentin removed, increase in the volume of the canal, increase in the surface area of the canal, SMI, unprepared surfaces of the canal and volume of debris.
26

Avaliação do preparo de canais radiculares realizado por sistemas mecanizados com cinemática reciprocante cêntrica e rotatória excêntrica, por meio da microtomografia computadorizada / Evaluation of root canal preparation performed by mechanized systems with centric reciprocating and eccentric rotatory kinematics, by microcomputed tomography

Fernandes, Priscilla Oliveira Fonseca 15 February 2018 (has links)
Dentre as etapas do tratamento endodôntico, a limpeza e modelagem tem especial atenção, já que a conformação geométrica satisfatória e a sanificação dos canais radiculares propiciam condições favoráveis ao controle da infecção e à adequada obturação do espaço endodôntico. O desenvolvimento de instrumentos fabricados a partir da liga de níquel-titânio (NiTi) contribuiu de maneira importante para a melhora na qualidade e previsibilidade do preparo endodôntico. Os diferentes sistemas mecanizados que são propostos constantemente no mercado devem ser avaliados com detalhes, pois sua performance pode variar de acordo com as características de fabricação e design de cada instrumento. O objetivo deste estudo foi avaliar, por meio da microtomografia computadorizada (micro-CT), o preparo de canais mesiais de molares inferiores com o sistema XP-endo Shaper (XPS), comparando-o ao preparo realizado com instrumentos do sistema Reciproc (REC), quanto ao volume de debris dentinários remanescentes, área de paredes não tocadas, dentina excisada, aumento do volume e superfície do canal radicular e desvio do canal original no terço apical. Vinte e quatro raízes mesiais de molares inferiores, com dois canais e um forame, foram anatomicamente pareadas e divididas em 2 grupos experimentais (n=12) de acordo com o sistema utilizado para o preparo químico cirúrgico: Grupo XPS e Grupo REC. Os espécimes foram escaneados por um microtomógrafo de raios-X (SkyScan 1176) com resolução de 17.42 ?m pré e pós preparo. Com o auxílio dos softwares Dataviewer, CTan e CTVol foi possível a avaliação tridimensional do canal para observação das mudanças nos parâmetros estudados. Os dados obtidos foram comparados e, onde se identificou distribuição normal e homogeneidade das variâncias, foi utilizado o Teste t de student para analisar as hipóteses experimentais. Para os dados onde se observou distribuição não-normal, optou-se pelo teste não-paramétrico numérico (Mann- Whitney). Todos as análises foram realizadas com nível de significância de 5%. Nos resultados, em toda extensão do canal radicular, assim como para as análises por terços, não houve diferença estatisticamente significativa entre os grupos quanto ao transporte do canal, volume de dentina excisada e aumento do volume e superfície do canal. Identificou-se diferença significativa (p < 0,05) entre os grupos quanto a área de superfície não tocada, onde observou-se que, no canal total e nos terços cervical e médio, o grupo XPS preparou maior área do canal do que o grupo REC. Quanto ao volume e percentual de debris dentinários acumulados, o grupo REC apresentou valores estatisticamente maiores na totalidade do canal e nos terços médio e apical, evidenciando maior acúmulo de debris intra-radiculares do que o grupo XPS. Concluiuse que as técnicas de preparo avaliadas se comportaram de maneira semelhante quanto ao aumento de volume e superfície do canal, volume de dentina removida e desvio apical. Em contrapartida, o sistema XPS, por possuir cinemática rotatória excêntrica, conseguiu tocar maior quantidade de paredes e eliminar maior volume percentual de debris acumulados em relação ao sistema que se vale de cinemática reciprocante cêntrica (REC). / Among the stages of endodontic treatment, cleaning and shaping should have special attention, since a satisfactory geometry and sanification of the root canals provide favorable conditions for infection control and adequate endodontic obturation. The development of the Niquel-Titanium (NiTi) instruments contributed to the improvement in quality and predictability of the endodontic preparation. The new mechanized systems that are constantly proposed in the market must be evaluated, as their performance can vary according to the manufacturing and design features of each instrument. The purpose of this study was to evaluate, using microcomputed tomography (micro-CT), the preparation of mesial root canals of mandibular molars with the new XP-endo Shaper (XPS) system comparing it to the preparation performed with Reciproc instruments (REC), evaluating the volume of remaining dentin debris, area of untouched walls, dentin removed, increase in volume and surface of the root canal and apical tranportation. Twenty-four mandibular molar mesial roots with two canals and one foramen were anatomically matched and divided into 2 experimental groups (n = 12) according to the system used for shaping: XPS Group and REC Group. The specimens were scanned pre and post preparation by a X-ray microtomograph (SkyScan 1176) with a resolution of 17.42 ?m. With Dataviewer, CTan and CTVol softwares, it was possible a tridimensional evaluation of the root canal in order to observe changes in the studied parameters. The data were compared and, where normal distribution and homogeneity of variances were identified, Student\'s t test was used to analyze the experimental hypotheses. For the data where non-normal distributions were observed, the non-parametric numerical test (Mann-Whitney) was chosen. All analyzes were performed with a significance level of 5%. In the results, in all extension of the root canal, as well as for analyzes by thirds, there was no statistically significant difference between the groups regarding apical transportation, volume of removed dentin and increase of volume and canal surface. A significant difference (p <0.05) was found between the groups regarding the untouched surface area, where in the total canal and in the cervical and middle thirds, the XPS group prepared a larger area of the canal than the group REC. As to the volume and percentage of accumulated dentinal debris, the REC group presented statistically higher values in the whole canal and in the middle and apical thirds, evidencing a higher accumulation of intra-radicular debris than the XPS group. It was concluded that the preparation techniques evaluated behaved similarly to the changes in volume and surface of the canal, the volume of dentin removed and the apical tranportation. The XPS system by its eccentric rotational kinematics was able to touch a larger number of walls and eliminate a greater percentage volume of accumulated debris compared to the system that uses a centralized reciprocating motion.
27

Avaliação do preparo de canais radiculares realizado por sistemas mecanizados com cinemática reciprocante cêntrica e rotatória excêntrica, por meio da microtomografia computadorizada / Evaluation of root canal preparation performed by mechanized systems with centric reciprocating and eccentric rotatory kinematics, by microcomputed tomography

Priscilla Oliveira Fonseca Fernandes 15 February 2018 (has links)
Dentre as etapas do tratamento endodôntico, a limpeza e modelagem tem especial atenção, já que a conformação geométrica satisfatória e a sanificação dos canais radiculares propiciam condições favoráveis ao controle da infecção e à adequada obturação do espaço endodôntico. O desenvolvimento de instrumentos fabricados a partir da liga de níquel-titânio (NiTi) contribuiu de maneira importante para a melhora na qualidade e previsibilidade do preparo endodôntico. Os diferentes sistemas mecanizados que são propostos constantemente no mercado devem ser avaliados com detalhes, pois sua performance pode variar de acordo com as características de fabricação e design de cada instrumento. O objetivo deste estudo foi avaliar, por meio da microtomografia computadorizada (micro-CT), o preparo de canais mesiais de molares inferiores com o sistema XP-endo Shaper (XPS), comparando-o ao preparo realizado com instrumentos do sistema Reciproc (REC), quanto ao volume de debris dentinários remanescentes, área de paredes não tocadas, dentina excisada, aumento do volume e superfície do canal radicular e desvio do canal original no terço apical. Vinte e quatro raízes mesiais de molares inferiores, com dois canais e um forame, foram anatomicamente pareadas e divididas em 2 grupos experimentais (n=12) de acordo com o sistema utilizado para o preparo químico cirúrgico: Grupo XPS e Grupo REC. Os espécimes foram escaneados por um microtomógrafo de raios-X (SkyScan 1176) com resolução de 17.42 ?m pré e pós preparo. Com o auxílio dos softwares Dataviewer, CTan e CTVol foi possível a avaliação tridimensional do canal para observação das mudanças nos parâmetros estudados. Os dados obtidos foram comparados e, onde se identificou distribuição normal e homogeneidade das variâncias, foi utilizado o Teste t de student para analisar as hipóteses experimentais. Para os dados onde se observou distribuição não-normal, optou-se pelo teste não-paramétrico numérico (Mann- Whitney). Todos as análises foram realizadas com nível de significância de 5%. Nos resultados, em toda extensão do canal radicular, assim como para as análises por terços, não houve diferença estatisticamente significativa entre os grupos quanto ao transporte do canal, volume de dentina excisada e aumento do volume e superfície do canal. Identificou-se diferença significativa (p < 0,05) entre os grupos quanto a área de superfície não tocada, onde observou-se que, no canal total e nos terços cervical e médio, o grupo XPS preparou maior área do canal do que o grupo REC. Quanto ao volume e percentual de debris dentinários acumulados, o grupo REC apresentou valores estatisticamente maiores na totalidade do canal e nos terços médio e apical, evidenciando maior acúmulo de debris intra-radiculares do que o grupo XPS. Concluiuse que as técnicas de preparo avaliadas se comportaram de maneira semelhante quanto ao aumento de volume e superfície do canal, volume de dentina removida e desvio apical. Em contrapartida, o sistema XPS, por possuir cinemática rotatória excêntrica, conseguiu tocar maior quantidade de paredes e eliminar maior volume percentual de debris acumulados em relação ao sistema que se vale de cinemática reciprocante cêntrica (REC). / Among the stages of endodontic treatment, cleaning and shaping should have special attention, since a satisfactory geometry and sanification of the root canals provide favorable conditions for infection control and adequate endodontic obturation. The development of the Niquel-Titanium (NiTi) instruments contributed to the improvement in quality and predictability of the endodontic preparation. The new mechanized systems that are constantly proposed in the market must be evaluated, as their performance can vary according to the manufacturing and design features of each instrument. The purpose of this study was to evaluate, using microcomputed tomography (micro-CT), the preparation of mesial root canals of mandibular molars with the new XP-endo Shaper (XPS) system comparing it to the preparation performed with Reciproc instruments (REC), evaluating the volume of remaining dentin debris, area of untouched walls, dentin removed, increase in volume and surface of the root canal and apical tranportation. Twenty-four mandibular molar mesial roots with two canals and one foramen were anatomically matched and divided into 2 experimental groups (n = 12) according to the system used for shaping: XPS Group and REC Group. The specimens were scanned pre and post preparation by a X-ray microtomograph (SkyScan 1176) with a resolution of 17.42 ?m. With Dataviewer, CTan and CTVol softwares, it was possible a tridimensional evaluation of the root canal in order to observe changes in the studied parameters. The data were compared and, where normal distribution and homogeneity of variances were identified, Student\'s t test was used to analyze the experimental hypotheses. For the data where non-normal distributions were observed, the non-parametric numerical test (Mann-Whitney) was chosen. All analyzes were performed with a significance level of 5%. In the results, in all extension of the root canal, as well as for analyzes by thirds, there was no statistically significant difference between the groups regarding apical transportation, volume of removed dentin and increase of volume and canal surface. A significant difference (p <0.05) was found between the groups regarding the untouched surface area, where in the total canal and in the cervical and middle thirds, the XPS group prepared a larger area of the canal than the group REC. As to the volume and percentage of accumulated dentinal debris, the REC group presented statistically higher values in the whole canal and in the middle and apical thirds, evidencing a higher accumulation of intra-radicular debris than the XPS group. It was concluded that the preparation techniques evaluated behaved similarly to the changes in volume and surface of the canal, the volume of dentin removed and the apical tranportation. The XPS system by its eccentric rotational kinematics was able to touch a larger number of walls and eliminate a greater percentage volume of accumulated debris compared to the system that uses a centralized reciprocating motion.

Page generated in 0.0938 seconds