• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 15
  • 2
  • Tagged with
  • 17
  • 17
  • 16
  • 16
  • 9
  • 8
  • 8
  • 7
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Comparison of the mechanical properties of engine-driven nickel- titanium instruments manufactured by different thermal treatments / Comparação das propriedades mecânicas de instrumentos mecanizados de níquel-titânio fabricados com diferentes tratamentos térmicos

Murilo Priori Alcalde 03 April 2018 (has links)
The aim of this study was to evaluate the mechanical properties of engine-driven Nickel-Titanium instruments manufactured by different thermal treatments. In the first part of this study, 60 reciprocating instruments were used (n=20): Reciproc R25 (REC 25.08), Unicone L25 (UNC 25.06) e Prodesign R 25 (PDR 25.06). The cyclic flexural fatigue resistance was performed measuring the time to failure in an artificial stainless steel canal with a 60º angle and a 5 mm radius of curvature (n=10). The torsional test was performed according to ISO 3630-1, measuring the torque and angle of rotation at failure in the 3 mm from the tip portion (n=10). Additionally, the fractured surface of each instrument was examined by scanning electron microscopy (SEM) to assess the topographic features of the fractured surface. Data were analyzed using one was analysis of variance ANOVA and Tukey test, the level of significance was set at 5%. The results of the cyclic flexural fatigue showed that PDR 25.06 presented significantly higher values than the other groups (P<0.05). REC 25.08 showed higher fatigue resistance than UNC 25.06 (P<0.05). In relation to the torsional test, the PDR 25.06 presented the lowest torque load than REC 25.08 and UNC 25.06 (P<0.05). In addition, there was no significant difference between REC 25.08 and UNC 25.06 (P>0.05). The PDR 25.06 and UNC 25.06 showed higher angular rotation until fracture than REC 25.08 (P<0.05). No difference was found between PDR 25.06 and UNC 25.06. All the instruments showed typical topographic features of cyclic flexural and torsional fatigue. The second part of this study evaluated the cyclic flexural and torsional fatigue resistance of reciprocating instruments Reciproc Blue (RB 25.08), WaveOne Gold Primary (WOG 25.07) and Prodesign R 25 (PDR 25.06) (n=20). The cyclic flexural fatigue test was performed with the same previsoly described device, using a root curvature with 60º and a 5 mm radius (n=10) and the torsional test was performed according to ISO 3630-1 (n=10). The fractured surface of each instrument was examined by scanning electron microscopy (SEM). Data were analyzed using one was analysis of variance ANOVA and Tukey test, the level of significance was set at 5%. The results of the cyclic flexural fatigue test showed that PDR 25.06 presented significantly higher values than the other groups (P<0.05). RB 25.08 showed higher fatigue resistance than WOG 25.07 (P<0.05). The torsional test showed that PDR 25.06 had lowed torsional load (P<0.05). No difference was found between RB 25.08 and WOG 25.07 (P>0.05). In relation the angular rotation, the PDR 25.06 showed higher angular rotation values than RB 25.08 and WOG 25.07 (P<0.05). RB 25.08 presented higher angular values than WOG 25.07 (P<0.05). All the instruments showed typical topographic features of cyclic flexural and torsional fatigue. The third part of this study was to evaluate the torsional fatigue resistance of NiTi rotary glide path instruments. The torsional test was performed according to ISO 3630-1, measuring the torque and angle of rotation at failure in the 3 mm from the tip portion. A total of 56 glide path instruments were used (n=8): Logic 25.01 (LOG 25.01), Logic CM 25.01(LOG CM 25.01), Proglider 16.02 (PGD 16.02), Hyflex GPF 15.01, 15.02, 20.02 (HGPF) and Mtwo 10.04. The fractured surface of each instrument was examined by scanning electron microscopy (SEM). Data were analyzed using one was analysis of variance ANOVA and Tukey test, the level of significance was set at 5%. The results showed that LOG 25.01 had a significantly higher torsional load than the other groups (P<0.05). The PGD 16.02 had significantly difference in comparison with HGPF 15.01 and 15.02 (P<0.05). LOG CM 25.01 had higher torsional load than HGPF 15.01 and 15.02 (P<0.05). No difference was found among Mtwo 10.04, HGPG 15.01, 15.02 and 20.02. In relation the angular rotation, LOG CM 25.01 and HGPF 15.01 presented the highest values (P<0.05). PGD 16.02 had the lowest values (P<0.05) followed by Mtwo 10.04. LOG 25.01 had higher angle of rotation than PGD 16.02 and Mtwo 10.04 (P<0.05). All the instruments showed typical topographic features of torsional fatigue. / O objetivo deste estudo foi avaliar o comportamento mecânico de instrumentos mecanizados de Níquel-Titânio (NiTi) fabricados com diferentes tratamentos térmicos. Na primeira parte do estudo foram utilizados 60 instrumentos reciprocantes para a realização dos teste de fadiga cíclica flexural e torcional (n=20): Reciproc R25 (REC 25.08), Unicone L25 (UNC 25.06) e Prodesign R 25 (PDR 25.06). O teste de fadiga cíclica flexural foi realizado com o objetivo de mensurar o tempo para a fratura dos instrumentos em um canal artificial de aço inoxidável com curvatura com 60º de angulação e 5 mm de raio (n=10). Para o teste de torção, os 3 mm inicias das pontas dos instrumentos foram fixadas em um aparelho de torção (n=10), de acordo com a norma ISO 3630-1. Este teste foi realizado com o objetivo de mensurar o torque máximo e o ângulo de rotação suportado pelos instrumentos até sua fratura. Adicionalmente, todos os fragmentos dos instrumentos fraturados foram examinados em microscopia eletrônica de varredura (MEV) para avaliar as características topográficas da superfície da área da fratura. A análise-estatística foi realizada utilizando o teste de análise de variância com um fator ANOVA e teste de Tukey, o nível de significância foi de 5%. Os resultados de fadiga cíclica flexural demonstraram que o PDR 25.06 apresentou maior tempo para a fratura do que os outros grupos (P<0.05). O instrumento REC 25.08 apresentou maior resistência a fadiga cíclica flexural do que o UNC 25.06 (P<0.05). O teste de torção demonstrou que o PDR 25.06 apresentou significantemente menor resistência torcional do que o REC 25.08 e UNC 25.06 (P<0.05). Além disso, não houve diferença entre REC 25.08 e UNC 25.06. Com relação ao ângulo de rotação, o PDR 25.06 e UNC 25.06 apresentaram diferença significante quando comparado ao REC 25.08. Não houve diferença entre PDR 25.06 e UNC 25.06 (P>0.05). Todos os instrumentos apresentaram característica topográficas típicas de fadiga cíclica flexural e torcional. Na segunda parte deste estudo avaliou-se a fadiga cíclica flexural e torcional dos instrumentos reciprocantes Reciproc Blue R25 (RB 25.08), WaveOne Gold Primary (WOG 25.07) e Prodesign R 25 (PDR 25.06) (n=20). O teste de fadiga cíclica flexural foi realizado com dispositivo descrito anteriormente, utilizando curvaturas de 60º e 5 mm de raio (n=10). O teste de torção foi realizado de acordo com a norma ISO 3630-1 (n=10). Todos os fragmentos dos instrumentos fraturados foram examinados em microscopia eletrônica de varredura (MEV) para avaliar as características topográficas da superfície da área da fratura. A análise-estatística foi realizada utilizando o teste de análise de variância com um fator (ANOVA) e teste de Tukey, o nível de significância foi de 5%. Os resultados de fadiga cíclica flexural demonstraram que o PDR 25.06 apresentou a maior resistência a fadiga cíclica flexural do que dos outros grupos (P<0.05). O RB 25.08 apresentou maior tempo para à fratura do que o WOG 25.07 (P<0.05). O teste de torção, o PDR 25.06 apresentou a menor resistência à torção do que os outros grupos (P<0.05). Não houve diferença significante entre RB 25.08 e WOG 25.07 (P>0.05). Em relação ao ângulo de rotação, o PDR 25.06 apresentou maiores valores quando comparados com RB 25.08 e WOG 25.07. O RB 25.08 apresentou diferença significante quando comparado com WOG 25.07. Todos os instrumentos apresentaram características topográficas típicas de fadiga cíclica flexural e torcional. Na terceira parte deste estudo avaliou-se a resistência torcional de instrumentos empregados para patência do canal radicular, de acordo com a norma ISO 3630-1. Foram utilizados 56 instrumentos rotatórios (n=8): Logic 25.01 (LOG 25.01), Logic CM 25.01 (LOG CM 25.01), Proglider 16.02 (PGD 16.02), Hyflex GPF 15.01, 15.02, 20.02 (HGPF) e Mtwo 10.04. Os fragmentos dos instrumentos fraturados foram examinados em microscopia eletrônica de varredura (MEV) para avaliar as características topográficas da superfície da área da fratura. A análise-estatística foi realizada utilizando o teste de análise de variância com um fator ANOVA e teste de Tukey, o nível de significância foi de 5%. Os resultados demonstraram que o LOG 25.01 apresentou significantemente maior resistência torcional do que os demais grupos (P<0.05). O grupo da PGD 16.02 apresentou diferença significante quando comparado com HGPF 15.01 e 15.02 (P<0.05). O LOG CM 25.01 apresentou maior resistência torcional do que o grupo do HGPF 15.01 e 15.02 (P<0.05). Não houve diferença significante entre os intrumentos Mtwo 10.04 e HGPF 15.01, 15.02 e 20.02. Com relação ao ângulo de rotação, o LOG CM 25.01 e HGPF 15.01 apresentaram os maiores valores (P<0.05). O PGD 16.02 apresentou o menor valor de todos os grupos (P<0.05) seguido pelo Mtwo 10.04. O LOG 25.01 apresentou maiores ângulos de rotação do que o PGD 16.02 e Mtwo 10.04 (P<0.05). Todos os instrumentos apresentaram característica topográficas típicas de fadiga torcional. As características da secção transversal, tipo de núcleo, taper e o tratamento térmico possuem forte influência sobre as propriedades mecânicas dos instrumentos de NiTi. No entanto, o tratamento térmico é um dos fatores primordiais para maior flexibilidade dos instrumentos. O instrumento PDR 25.06 apresentou maior resistência à fadiga cíclica flexural e maior ângulo de rotação no teste de torção do que todos os outros instrumentos reciprocantes avaliados. No entanto, menor resistência torcional. Os intrumentos LOG 25.01 apresentaram maior resistência torcional e o LOG CM 25.01 maiores ângulos de rotação.
12

Avaliação in vitro da remoção da camada residual (smear layer) de canais radiculares achatados instrumentados com quatro diferentes sistemas rotatórios com e sem associação de ultra-som e laser ER:YAG / Evaluation of smear layer removal of flatted canals after rotary instrumentation with four diferent NiTi instruments and association with Laser Er:YAG and ultrasonic

Alexandre Capelli 13 March 2008 (has links)
Estudou-se, por meio da microscopia eletrônica de varredura, a remoção da \"smear layer\" dos canais radiculares preparados com sistemas rotatórios com e sem \"radial land\". Após a preparação, as paredes dos canais radiculares foram submetidas aos tratamentos com ultra-som, aplicação do agente quelante EDTA a 15% e do laser Er:YAG. Noventa e seis incisivos inferiores humanos foram selecionados e divididos aleatoriamente em quatro grupos distintos, preparados com técnica rotatória Free Tip (Pecora et al, 2002) com instrumentos de níquel-titânio, 0,5 mm aquém do ápice anatômico, variando-se apenas o tratamento final das paredes do canal radicular. No grupo 1 utilizou-se o hipoclorito de sódio a 2,5% durante a instrumentação; no grupo 2 realizou-se irrigação com hipoclorito de sódio a 2,5% durante a instrumentação, recebendo posteriormente irradiação com laser Er:YAG (KaVo Key Laser II), com o auxílio de uma fibra óptica 30/28 de 285 &micro;m de diâmetro, gerando uma energia total de 42 J, freqüência de 15 Hz e potencia de 250mJ input (140mJ output). A cinemática utilizada na irradiação foi de movimento helicoidal de tração da fibra óptica, de apical para cervical, durante 10 segundos, sendo repetida quatro vezes; no grupo 3 utilizou-se a solução de hipoclorito de sódio a 2,5% ativada pelo ultra-som (MiniPiezon, EMS, Suíça); no grupo 4 utilizou-se a solução de hipoclorito de sódio a 2,5% e irrigação final com EDTA a 17%. Os espécimes foram preparados para microscopia eletrônica de varredura, e as fotomicrografias obtidas dos terços médio e apical submetidas a avaliação qualitativa por três observadores previamente calibrados, que atribuíam escores as imagens. A análise estatística revelou que a presença ou ausência da superfície radial de apoio (radial land) não interferiu na limpeza das paredes dos canais radiculares. Com relação ao tratamento final, o EDTA a 15% foi capaz de eliminar a \"smear layer\" com maior eficácia, sendo seguido pelo ultra-som e finalmente o laser Er:YAG. Houve diferença estatística significante entre os terços médio e apical dos canais radiculares. / This study evaluated, in vitro, smear layer removal in apical and middle root thirds after instrumentation with four different rotary Ni-Ti instruments and the use of Er:YAG laser, ultrasonic or EDTA. Nineth six mandibular incisors root canals were instrumented with Free Tip Technique, and irrigated with 10 ml of sodium hypochlorite. In Group 1, 24 teeth were instrumented and irrigated only with 10 ml of 2.5 % sodium hypochlorite. Group 24, instrumented as group 1 and irradiated laser Er:YAG in the following parameters: 30/28 fiber optic tip, 42 J, 15Hz and 250mJ input (140mJ output), with the tip activated at the apex and removed to the canal entrance in a helicoidal moviment. Group 3, instrumented as in group 1 and associated with ultrasonic. Group 4, instrumented as in group 1 and associated with with 15% EDTA. Electronic Microscope images were evaluated showed that group 4 had significantly less smear layer (p<0,05) than the group 1 and 2, with group 3 in intermediated position. We conclude that sodium hypochlorite associated with 15% EDTA lead to root canals with less smear layer. The middle third present less smear layer than apical third.
13

Avaliação da eficiência de sistemas rotatórios para desobturação em canais curvos, por meio de tomografia computadorizada por feixe cônico / Evaluation of the efficiency of rotary systems for remove filling materials in curved canals through cone beam computed tomography

Giovana Borba Gazzinelli Costa 02 December 2013 (has links)
O presente estudo teve por objetivo avaliar ex vivo a eficiência de sistemas para retratamento (ProTaper Universal Retratamento, Mtwo Retratamento e D-Race), na desobturação de canais mésio vestibulares curvos de molares superiores, por meio de tomografia computadorizada por feixe cônico. Foram utilizados canais mésio vestibulares com curvatura entre 20° e 40°, de 36 molares superiores, preparados com Protaper Universal (até instrumento F2), obturados com cone ProTaper F2 e cimento AH Plus, pela técnica de condensação lateral. Para a desobturação, os dentes foram divididos em grupos (I: ProTaper Universal Retratamento, II: Mtwo Retratamento e III: D-Race). A captura das imagens foi realizada após a obturação e após a desobturação dos canais radiculares, por meio de tomografia computadorizada por feixe cônico de pequeno volume (Prexion 3D XTrillion Inc). As imagens foram segmentadas utilizando o programa InVesalius, para verificar o material obturador remanescente. O tempo para desobturação também foi analisado. De posse dos valores, iniciais e finais, de volume de material obturador e de estrutura dentinária, a proporção dos volumes foi calculada. Para a análise estatística, os resultados foram avaliados pelos testes de ANOVA e de Múltiplas Comparações de Bonferroni. Os grupos ProTaper Universal Retratamento (13,97%) e D-Race (9,87%), apresentaram os menores volumes percentuais médios de material obturador remanescente, não havendo diferença estatística significante entre eles; porém, apresentaram diferença estatística significante (p 0,05) do grupo Mtwo Retratamento (33,88%). Os três sistemas provocaram desgaste semelhante de dentina após a desobturação. O grupo D-Race apresentou menor tempo para desobturação, estatisticamente diferente em relação aos demais sistemas. As características dos sistemas de retratamento podem interferir na eficiência de desobturação quanto ao tempo e volume de material remanescente. / The present study aimed to evaluate, ex vivo, the efficiency of systems for retreatment (ProTaper Universal Retreatment, Mtwo Retreatment and D-Race), in removal filling material of curved mesiobuccal canals of maxillary molars, using cone beam computed tomography. Were used mesiobuccal canals with curvature between 20 ° and 40 °, of 36 molars prepared with ProTaper Universal (until instrument F2), filled with cone F2 ProTaper and AH Plus sealer by lateral condensation. For the removal procedure of filling material, the teeth were divided into groups (I: Protaper Universal Retreatment, II: Mtwo Retreatment and III: D-Race). The capture of images was performed after filling and after the removal procedure of root canal through cone beam computed tomography of small volume (Prexion 3D - XTrillion Inc). The images were segmented using the software InVesalius to check the remaining filling material. The time for removal procedure was also analyzed. Possession of values, initial and final, of volume filling material and dentin structure, the ratio of the volumes was calculated. For statistical analysis, the results were evaluated by ANOVA and Bonferroni\'s Multiple Comparisons. ProTaper Universal Retreatment (13.97 %) and D-Race (9.87 %) groups had the lowest average percent volume remaining filling material, with no statistically significant difference between them, but showed a statistically significant difference (p 0.05) group Mtwo Retreatment (33.88 %). The three systems caused similar wear dentin after removal procedure. The group D-Race had less time for removal procedure, statistically different compared to the other systems. The characteristics of retreatment systems may interfere with the efficiency of removal procedure on the time and volume remaining material.
14

Análise comparativa ex vivo da quantidade de material extruído apicalmente por diferentes técnicas mecanizadas de instrumentação dos canais radiculares. / Ex vivo comparative analysis of the quantity of material extruded apically by different mechanized root canal debriding instruments.

Danielle Cristina Rosa 30 September 2009 (has links)
O tratamento endodôntico é constituído por uma sequência de fases que devem ser respeitadas e conduzidas com o mesmo grau de importância para o sucesso da terapia endodôntica. Atenção especial é dada a fase do o preparo biomecânico do canal radicular, que pode ocasionar extrusão de restos pulpares, tecido necrosado, rapas de dentina e substâncias químicas auxiliares através do forame apical, provocando uma reação inflamatória ou flare-up. Com o intuito de se obter um pós-operatório com êxito, realizou-se um estudo com o objetivo de avaliar, ex vivo, a quantidade de material extruído através do forame apical durante o preparo do canal radicular pelas seguintes técnicas: manual Step-Back, mecanizada rotatórias Crown Down e Free Tip Preparation. Trinta incisivos inferiores foram distribuídos aleatoriamente em 3 grupos (n=10), de acordo com as seguintes técnicas de instrumentação: G1- técnica manual Step Back (controle); G2- Crown Down; G3- Free Tip Preparation. Todos os grupos foram instrumentados a 0,5mm aquém do forame apical. O material extruído foi coletado em um Dispositivo Coletor de Material Extruído(DCME), confeccionado especificamente para essa finalidade e a extrusão apical foi calculada pela determinação da massa de material sólido extruído. Os valores obtidos foram analisados pelo teste de Kruskal- Wallis e o teste complementar de Dunn`s Multiple, com P=0.05, como nível de significância estatística. Os resultados mostraram que a técnica Step-Back promoveu maior quantidade de material extruído através do forame apical; e que não houve diferença estatística significante entre as técnicas Crown Down e Free Tip Preparation. Pode-se concluir também que houve extrusão de material sólido através do forame apical em todas as técnicas de instrumentação estudadas. / Endodontic treatment is constituted of a sequence of stages that must be respected and performed with the same degree of importance in order to ensure the success of endodontic therapy. Special attention is paid to the stage of biomechanical preparation of the root canal, which may cause the extrusion of pulp remainders, necrotic tissue, dentin scrapings and auxiliary chemical substances through the apical foramen, causing an inflammatory reaction or flare-up. With the intention of achieving successful post-operative period, a study was conducted with the aim of making an ex vivo evaluation of the quantity of material extruded through the apical foramen during root canal preparation, by means of the following techniques: manual Step-Back, mechanized rotary Crown Down and Free Tip Preparation. Afterwards, the teeth were randomly assigned to three equal groups (n=15) according to post length, as follows: G1 manual Step-Back technique (control); G2 - Crown Down; G3 - Free Tip Preparation. All the groups were instrumented to 0.5 mm short of the apical foramen. The extruded was collected in an Extruded Material Collecting Device (EMCD), made specifically for this purpose, and apical extrusion was calculated by determining the mass of solid material extruded. The values obtained were analyzed by the Kruskal-Wallis test and complementary Dunns Multiple test, with P=0.05, as the level of statistical significance. The results showed that the Step-Back technique promoted the largest amount of material extruded through the apical foramen; and that there was no statistically significant difference between the Crown Down and Free Tip Preparations. It could also be concluded that there was extrusion of solid material through the apical foramen in all the studied instrumentation techniques used.
15

Avaliação de erros operatórios durante o preparo do canal radicular após o uso de instrumentos rotatórios de níquel-titânio realizados por estudantes e especialistas / Operative evaluation of errors during the preparation of root canal after the use of rotary instruments nickel-titanium made by students and specialists

OLIVEIRA, Henrique Cesar Marcal de 26 February 2010 (has links)
Made available in DSpace on 2014-07-29T15:22:00Z (GMT). No. of bitstreams: 1 dissertacao henrique c m oliveira.pdf: 1002486 bytes, checksum: eddcaf3f31b0f29703a16146f9f05b7d (MD5) Previous issue date: 2010-02-26 / The aim of this study was to determine the errors of procedures that occurred during the preparation of curved root canals after the use of instruments níqueltitânio powered motor managed by specialists in endodontics and dental students. Forty upper and lower molars of humans were randomly divided into two groups of 20, according to traders: G1A-(Molars, specialists in endodontics), G1B-(lower molars, specialists in endodontics), G2A-(molars, dental students), G2B-(lower molars, dental students). The ProTaper Universal System was used to prepare all root canals. The AH PlusTM associated with gutta-percha was used with lateral condensation technique for obturation of all canals. Periapical radiography and cone beam computed tomography (TCFC) were obtained to verify procedural errors occurred during the preparation of root canals. Two examiners evaluated all images for determining the presence or absence of instrument fracture, root perforation (cervical, middle or apical) and deviation original path of the root canal (apical transport). The data were statistically analyzed employing the Chi-square test. The significance level was 5%. The rate of fractured instruments showed no significant differences in the level of experience of operators (p = 1.000). Root perforations and transport apical occurred more frequently in the group of students, without significant differences. While there have been some procedural errors during root canal preparation with experienced and inexperienced operators, the results suggest that the introduction of tools of nickel-titanium engine-driven education / O objetivo deste estudo foi determinar os erros de procedimentos ocorridos durante o preparo de canais radiculares curvos após o uso de instrumentos de níqueltitânio acionados a motor manejados por especialistas em endodontia e estudantes de odontologia. Quarenta molares superiores e inferiores de humanos foram aleatoriamente divididos em dois grupos de 20, de acordo com os operadores: G1A- (molares superiores, especialistas em endodontia), G1B- (molares inferiores, especialistas em endodontia); G2A- (molares superiores, estudantes de odontologia), G2B- (molares inferiores, estudantes de odontologia). O sistema ProTaper Universal foi usado para o preparo de todos os canais radiculares. O cimento AH PlusTM associado com a guta-percha foi usado com a técnica da condensação lateral para a obturação de todos os canais radiculares. Radiografias periapicais e tomografia computadorizada de feixe cônico (TCFC) foram obtidas para verificar erros de procedimentos ocorridos durante o preparo dos canais radiculares. Dois examinadores avaliaram todas as imagens determinando a presença ou ausência de fratura de instrumentos, perfurações radiculares (terço cervical, médio ou apical) e desvio do trajeto original do canal radicular (transporte apical). Os dados foram estatisticamente avaliados empregando-se o teste Qui-quadrado. O nível de significância foi de 5%. A taxa de instrumentos fraturados não mostrou diferenças significantes em relação ao nível de experiência dos operadores (p=1,000). Perfurações radiculares e transportes apicais ocorreram mais frequentemente no grupo dos estudantes, sem diferenças significantes. Embora tenham sido observados alguns erros de procedimentos durante o preparo do canal radicular com operadores experientes e inexperientes, os resultados sugerem que a introdução de instrumentos de níquel-titânio movidos a motor no ensino da graduação parece promissora. Ambos os métodos de imagens permitiram identificar erros operatórios, porém a tomografia computadorizada de feixe cônico apresenta elevado potencial de auxiliar a terapia endodôntica.
16

"Influência da técnica de desobturação e do limite de obturação na extrusão apical" / Apical extrusion: influence on gutta-percha removal technique and root filling limit.

Esteves, Cristiane Linge Exposito 24 November 2004 (has links)
O controle da extrusão apical durante a reintervenção endodôntica é essencial para o sucesso do novo tratamento. Nesse contexto, o presente estudo teve como objetivo comparar a quantidade de material sólido extruído na desobturação de canais radiculares variando-se a técnica de esvaziamento e o limite de obturação. Foram utilizados 40 incisivos inferiores previamente tratados divididos em dois grupos de acordo com o limite de obturação estabelecido. Cada grupo foi subdividido em dois subgrupos levando-se em conta a técnica de desobturação empregada; manual (subgrupos A1 e B1) e mecânico-rotatória com limas de Ni-Ti (Quantec LX) (subgrupos A2 e B2). O material sólido extruído foi coletado por meio do sistema de filtração Millipore, levado à secagem em dessecador de sílica e pesado em balança analítica de precisão. Os resultados obtidos foram submetidos a ANOVA para dois fatores de variação sendo em seguida empregado o Teste de Tukey (&#945; = 5%). A técnica de desobturação mecânico-rotatória produziu menor extrusão (0,66mg) que a manual (1,11mg), havendo diferença estatística significante entre elas (p < 0,05). Os canais preenchidos até o vértice radiográfico apresentaram maior quantidade de extrusão (1,38mg) do que os obturados 1 mm aquém do forame (0,39mg), observando-se diferença estatística significante entre eles (p < 0,05). A menor quantidade extrusão foi observada no subgrupo A2 (0,20mg), em que foi empregada a técnica rotatória de desobturação em canais obturados 1mm aquém do forame apical, sendo constatada diferença estatisticamente significante deste subgrupo com os demais (p < 0,05). A extrusão de material sólido durante a desobturação de canais radiculares é influenciado pela técnica empregada e pelo limite apical de obturação. / The apical extrusion control during the endodontic retreatment is essential for the success of the new treatment. The purpose of this study was to compare the quantity of solid apically extruded material during filling removal according the gutta-percha removal technique and root filling limit. Forty mandibular incisors with a single straight canal were selected. The canals were previously endodontically treated and then divided into two groups according the filling level. Each group was subdivided in two groups considering the retreatment technique: stainless steel hand files (subgroups A1 and B1) versus niquel-titanium rotatory instruments (subgroups A2 and B2). The extruded solid material was collected by Millipore filtration system, dried in silica desiccators and weighed in an eletrobalance. The results were analyzed using ANOVA with two variation factors and Tukey Test (&#945; = 5%). The niquel-titanium rotatory instruments produced less extrusion (0,66mg) than the stainless steel hand files (1,11mg), with significant statistical difference between them (p < 0,05). The canals filled until the radiographic apex showed larger amount of extruded material (1,38mg) than those filled 1 mm beyond the foramen (0,39mg). It was observed significant statistical difference between them (p < 0,05). The smaller extruded debris amount was observed in subgroup A2 (0,20mg), in which one the rotary technique was used to remove the gutta-percha of canals filled 1mm beyond the apical foramen. It was verified significant statistical difference of this subgroup with the other ones (p < 0,05). The extrusion of solid material during the gutta-percha removal is influenced by the technique as well as the apical filling limit.
17

"Influência da técnica de desobturação e do limite de obturação na extrusão apical" / Apical extrusion: influence on gutta-percha removal technique and root filling limit.

Cristiane Linge Exposito Esteves 24 November 2004 (has links)
O controle da extrusão apical durante a reintervenção endodôntica é essencial para o sucesso do novo tratamento. Nesse contexto, o presente estudo teve como objetivo comparar a quantidade de material sólido extruído na desobturação de canais radiculares variando-se a técnica de esvaziamento e o limite de obturação. Foram utilizados 40 incisivos inferiores previamente tratados divididos em dois grupos de acordo com o limite de obturação estabelecido. Cada grupo foi subdividido em dois subgrupos levando-se em conta a técnica de desobturação empregada; manual (subgrupos A1 e B1) e mecânico-rotatória com limas de Ni-Ti (Quantec LX) (subgrupos A2 e B2). O material sólido extruído foi coletado por meio do sistema de filtração Millipore, levado à secagem em dessecador de sílica e pesado em balança analítica de precisão. Os resultados obtidos foram submetidos a ANOVA para dois fatores de variação sendo em seguida empregado o Teste de Tukey (&#945; = 5%). A técnica de desobturação mecânico-rotatória produziu menor extrusão (0,66mg) que a manual (1,11mg), havendo diferença estatística significante entre elas (p < 0,05). Os canais preenchidos até o vértice radiográfico apresentaram maior quantidade de extrusão (1,38mg) do que os obturados 1 mm aquém do forame (0,39mg), observando-se diferença estatística significante entre eles (p < 0,05). A menor quantidade extrusão foi observada no subgrupo A2 (0,20mg), em que foi empregada a técnica rotatória de desobturação em canais obturados 1mm aquém do forame apical, sendo constatada diferença estatisticamente significante deste subgrupo com os demais (p < 0,05). A extrusão de material sólido durante a desobturação de canais radiculares é influenciado pela técnica empregada e pelo limite apical de obturação. / The apical extrusion control during the endodontic retreatment is essential for the success of the new treatment. The purpose of this study was to compare the quantity of solid apically extruded material during filling removal according the gutta-percha removal technique and root filling limit. Forty mandibular incisors with a single straight canal were selected. The canals were previously endodontically treated and then divided into two groups according the filling level. Each group was subdivided in two groups considering the retreatment technique: stainless steel hand files (subgroups A1 and B1) versus niquel-titanium rotatory instruments (subgroups A2 and B2). The extruded solid material was collected by Millipore filtration system, dried in silica desiccators and weighed in an eletrobalance. The results were analyzed using ANOVA with two variation factors and Tukey Test (&#945; = 5%). The niquel-titanium rotatory instruments produced less extrusion (0,66mg) than the stainless steel hand files (1,11mg), with significant statistical difference between them (p < 0,05). The canals filled until the radiographic apex showed larger amount of extruded material (1,38mg) than those filled 1 mm beyond the foramen (0,39mg). It was observed significant statistical difference between them (p < 0,05). The smaller extruded debris amount was observed in subgroup A2 (0,20mg), in which one the rotary technique was used to remove the gutta-percha of canals filled 1mm beyond the apical foramen. It was verified significant statistical difference of this subgroup with the other ones (p < 0,05). The extrusion of solid material during the gutta-percha removal is influenced by the technique as well as the apical filling limit.

Page generated in 0.0639 seconds