• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 57
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 59
  • 59
  • 59
  • 44
  • 44
  • 42
  • 39
  • 37
  • 36
  • 29
  • 15
  • 15
  • 14
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação de Kerma na superfície de entrada da pele em pacientes pediátricos do Hospital de Clínicas de Curitiba

Porto, Lorena Elaine 09 April 2010 (has links)
CAPES / No presente trabalho foram feitas medidas de dose recebida pelos pacientes pediátricos em exames de radiográficos de tórax em uma amostra de 386 exposições nas projeções AP/PA e Perfil. Os pacientes foram divididos em nas faixas etárias de 0-1 ano, 1-5 anos, 5-10 anos e 10-15 anos. Os exames foram realizados no Hospital de Clínicas da UFPR. Foi medida inicialmente a dose de entrada na pele com dosímetros termoluminescentes TLD-100 em uma amostra de 68 exposições, distribuídos pelas faixas etárias adotadas. A dose foi também determinada utilizando-se cálculos dosimétricos, que faz a determinação de dose para cada paciente a partir do rendimento do aparelho de raios X. O programa utiliza como dados de entrada a massa do paciente, a idade, a distância foco-pele, os dados da técnica radiográfica empregada (kV e mAs) e o valor de uma medida do rendimento feita com câmara de ionização para fins de calibração. Os primeiros dados avaliados mostraram doses maiores para os pacientes mais jovens. Uma mudança na técnica radiográfica dos exames contribuiu para a redução das doses. Foi avaliado todo o procedimento radiográfico e ficou caracterizada a necessidade de uma adequação da técnica radiográfica e uma constante otimização de todo o procedimento. Os dados foram colhidos novamente em 2007 e depois em 2009. Num primeiro momento os níveis de dose se mantiveram. Em 2009 os valores voltaram a subir devido ao aumento da carga (mAs). Os dados obtidos foram então comparados com os limites de dose permissíveis determinados pelos órgãos competentes. / In the present work absorbed doses by pediatric patients in chest radiographs were measured in 386 x-ray examinations in AP/PA and LAT projections. The patients were divided in age groups of 0-1 years, 1-5 years, 5-10 years and 10-15 years. The examinations were made at the pediatric room of Clinical Hospital of the Federal University of Paraná. Initially the entrance skin dose was measured with thermoluminescent dosimeters TLD-100 in 68 expositions, distributed in the age groups. The dose was also determined with the software dosimetric calculations that calculates the dose for each patient, from the X-ray equipment yield. The program uses the following data as input: patient mass, age, skin-focus, radiographic technique (kV, mAs), and the yield measurement made with an ionization chamber for calibration. The first evaluated data showed higher doses for the younger patients. A change in the radiographic technique of the examinations contributed to the reduction of the doses. The whole radiographic procedure was evaluated and, thus, showed that the radiographic technique had to be adjusted and the procedure as a whole had to be constantly optimized. Dates were measurement in 2007 again and after 2009. At a first moment the dose levels if had kept. In 2009 the values had come back to go up due to the increase of the load (mAs). The doses were then compared with the regulatory dose limits.
32

Estimulador galvânico vestibular para fMRI

Manczak, Tiago 30 July 2012 (has links)
Este trabalho apresenta o desenvolvimento de um estimulador galvânico vestibular para ser usado em experimentos de imageamento por ressonância magnética funcional (fMRI). Em experiências de fMRI é necessário a produção de estímulos somatossensoriais no paciente. Os estímulos devem ser sincronizados com a sequência de pulsos da fMRI. O estimulador foi dividido em circuitos analógicos (colocados dentro da sala do magneto) e circuitos digitais (sala de comando do sistema de MRI). A comunicação entre os circuitos é feita através de fibra óptica. Experimentos de fMRI realizados com voluntários demonstraram que o estimulador proposto é capaz de manter a sincronização com sistema de fMRI e pode ser usado para localizar as áreas do cérebro que são ativados pelo sistema vestibular. / This work presents the development of a galvanic vestibular stimulator to be used in functional magnetic resonance imaging experiments (fMRI). In fMRI experiments it is required the production of somatosensory stimuli in the patient must be sincronized with the fMRI pulse sequence. The stimulator circuits were divided in analog circuits (placed within the magnet room) and digital circuits (placed in the MRI command room). The communication between the circuits is made through optical fiber. fMRI experiments performed with volunteers demonstrated that the proposed stimulator is able to keep the sincronization with the MRI system and can be used to locate the brain areas that are activated by the vestibular system.
33

Estimulador elétrico neuromuscular bifásico com saída em ponte H isolada eletricamente

Gaiotto, Marcelo do Carmo Camargo 30 November 2012 (has links)
A eletrônica empregada no desenvolvimento de estimuladores elétricos funcionais contempla enorme diversificação de técnicas e tecnologias, cujas soluções para o estágio de saída variam desde circuitos transistorizados (bipolares ou MOSFETs), transformadores de pulso até amplificadores operacionais de alta tensão. Desenvolver um estimulador elétrico neuromuscular bifásico com saída em ponte H isolada eletricamente. O sistema de estimulação elétrica neuromuscular bifásico contém saída em ponte H utilizando somente transistores MOSFET canal N, permitindo a geração de pulsos bifásicos e monofásicos com controle de amplitude independente para cada pulso, por meio de uma plataforma eletrônica flexível, que possibilita sua utilização com diversos tipos de elementos de controle, desde microcontroladores e FPGA até dispositivos de instrumentação virtual do tipo LabView. Foram realizados testes de bancada que permitiram avaliar o desempenho do instrumento todo e de seus módulos separadamente. A faixa de alimentação utilizada nos testes foi de 12 a 24V, sendo relacionada diretamente a técnica de geração da alta tensão empregada que permitiu produzir de 280 V a 300 V, utilizados na ponte H, que por sua vez, apresentou o desempenho esperado fornecendo pulsos bifásicos com valores de pico a pico de até 600 V, que pudendo ter sua amplitude dos pulsos controlada individualmente com uma resolução de 73,26 mV (4096 passos), permitindo, assim, a geração de diferentes padrões estimulatórios criados a partir da interface gráfica. O estimulador projetado propiciou o desenvolvimento de uma nova técnica de saída em ponte H utilizando transistores MOSFET canal N na construção de estimuladores elétricos neuromusculares com saída bifásica e com controle de amplitude independente para cada pulso. Tal funcionalidade poderá contribuir para novos estudos e trabalhos em reabilitação empregando estimulação elétrica neuromuscular, considerando que, por meio da interface gráfica criada, formas de ondas estimulatórias específicas podem ser geradas. / The electronics used in the development of functional electrical stimulators include huge diversification of techniques and technologies, whose solutions for the output stage range from transistor circuits (bipolar or MOSFET), to pulse transformers and high-voltage operational amplifiers. To develop a biphasic neuromuscular electrical stimulator with electrically isolated H-bridge output. The electrical neuromuscular stimulation system contains biphasic H-bridge output using only N-channel MOSFET transistors, allowing the generation of mono and biphasic pulses whose pulse amplitudes are independently controlled by a flexible electronics platform, which enables its use with different types of control elements, from microcontroller and FPGA devices to Labview virtual instrument. Bench tests were performed that allowed to assess the performance of the instrument and all its modules separately. The power range used in the tests was 12 to 24V, the technique is directly related to generate the high voltage used which allowed to produce 280 V to 300 V, used in the H bridge, which in turn performed as expected providing pulses biphasic with peak to peak values of 600 V, which pudendal have its amplitude pulses individually controlled with a resolution of 73.26 mV (step 4096), thus allowing the generation of stimulatory different patterns created from the graphical interface. The project developed led the design of a new technique for H-bridge output using transistors N-channel MOSFET in the construction of biphasic neuromuscular electrical stimulator with independent amplitude control for each pulse. Such functionality can contribute to new studies and rehabilitation using neuromuscular electrical stimulation, whereas through the graphical user interface created stimulatory specific waveforms can be generated.
34

Avaliação de Kerma na superfície de entrada da pele em pacientes pediátricos do Hospital de Clínicas de Curitiba

Porto, Lorena Elaine 09 April 2010 (has links)
CAPES / No presente trabalho foram feitas medidas de dose recebida pelos pacientes pediátricos em exames de radiográficos de tórax em uma amostra de 386 exposições nas projeções AP/PA e Perfil. Os pacientes foram divididos em nas faixas etárias de 0-1 ano, 1-5 anos, 5-10 anos e 10-15 anos. Os exames foram realizados no Hospital de Clínicas da UFPR. Foi medida inicialmente a dose de entrada na pele com dosímetros termoluminescentes TLD-100 em uma amostra de 68 exposições, distribuídos pelas faixas etárias adotadas. A dose foi também determinada utilizando-se cálculos dosimétricos, que faz a determinação de dose para cada paciente a partir do rendimento do aparelho de raios X. O programa utiliza como dados de entrada a massa do paciente, a idade, a distância foco-pele, os dados da técnica radiográfica empregada (kV e mAs) e o valor de uma medida do rendimento feita com câmara de ionização para fins de calibração. Os primeiros dados avaliados mostraram doses maiores para os pacientes mais jovens. Uma mudança na técnica radiográfica dos exames contribuiu para a redução das doses. Foi avaliado todo o procedimento radiográfico e ficou caracterizada a necessidade de uma adequação da técnica radiográfica e uma constante otimização de todo o procedimento. Os dados foram colhidos novamente em 2007 e depois em 2009. Num primeiro momento os níveis de dose se mantiveram. Em 2009 os valores voltaram a subir devido ao aumento da carga (mAs). Os dados obtidos foram então comparados com os limites de dose permissíveis determinados pelos órgãos competentes. / In the present work absorbed doses by pediatric patients in chest radiographs were measured in 386 x-ray examinations in AP/PA and LAT projections. The patients were divided in age groups of 0-1 years, 1-5 years, 5-10 years and 10-15 years. The examinations were made at the pediatric room of Clinical Hospital of the Federal University of Paraná. Initially the entrance skin dose was measured with thermoluminescent dosimeters TLD-100 in 68 expositions, distributed in the age groups. The dose was also determined with the software dosimetric calculations that calculates the dose for each patient, from the X-ray equipment yield. The program uses the following data as input: patient mass, age, skin-focus, radiographic technique (kV, mAs), and the yield measurement made with an ionization chamber for calibration. The first evaluated data showed higher doses for the younger patients. A change in the radiographic technique of the examinations contributed to the reduction of the doses. The whole radiographic procedure was evaluated and, thus, showed that the radiographic technique had to be adjusted and the procedure as a whole had to be constantly optimized. Dates were measurement in 2007 again and after 2009. At a first moment the dose levels if had kept. In 2009 the values had come back to go up due to the increase of the load (mAs). The doses were then compared with the regulatory dose limits.
35

Visualização genérica de sinais e dados biomédicos em dispositivos móveis / Biomedic data visualization on mobile devices

Ortis, Rafael Santos 18 December 2009 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Elétrica, 2009. / Submitted by Jaqueline Ferreira de Souza (jaquefs.braz@gmail.com) on 2011-06-06T16:45:47Z No. of bitstreams: 1 2009_RafaelSantosOrtis.pdf: 2282385 bytes, checksum: 4b6f3a36e08f632897c2dbaa798f280c (MD5) / Approved for entry into archive by Jaqueline Ferreira de Souza(jaquefs.braz@gmail.com) on 2011-06-06T16:54:50Z (GMT) No. of bitstreams: 1 2009_RafaelSantosOrtis.pdf: 2282385 bytes, checksum: 4b6f3a36e08f632897c2dbaa798f280c (MD5) / Made available in DSpace on 2011-06-06T16:54:50Z (GMT). No. of bitstreams: 1 2009_RafaelSantosOrtis.pdf: 2282385 bytes, checksum: 4b6f3a36e08f632897c2dbaa798f280c (MD5) / O objetivo deste trabalho é o desenvolver de um sistema para a visualização móvel de sinais biomédicos de forma genérica e abrangendo a maior parte dos dispositivos móveis utilizando J2ME. O sistema proposto acessa os dados e sinais biomédicos de pacientes utilizando a arquitetura SOA. A visualização de sinais proposta neste trabalho se mostra eficiente para os dispositivos com resolução de tela pequena. A implementação de comunicação baseado em WebServices também garante maior interoperabilidade do sistema desenvolvido com diversos outros sistemas. A compressão dos dados no acesso ao serviço web mostra que é possível ter economia considerável (30%) na transmissão de dados. O desenvolvimento deste trabalho criou a base de um sistema genérico para a visualização de dados em dispositivos móveis. _______________________________________________________________________________ ABSTRACT / The objective of this work is to develop a system for visualization of biomedical signals in a generic way. The proposed system uses the SOA architecture to access data and biomedical signals of patients. The display of signals proposed in this paper proves to be effective for devices with a small screen resolution. The implementation of Web services based on communication also ensures a greater interoperability of the system developed with several other systems. The compression of data transmitted to web service shows that it is possible to have considerable savings (30%) in the transmission of data. Also the development of this work created the basis for a generic system for data visualization on mobile devices.
36

Um metodo para a avaliação de custos dos equipamentos medico-hospitalares nos procedimentos de assistencia a saude / A method for the evaluation of medical equipment costs within medical procedures

Nascimento, Leonardo Novaes do 12 August 2018 (has links)
Orientador: Saide Jorge Calil / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-12T16:40:12Z (GMT). No. of bitstreams: 1 Nascimento_LeonardoNovaesdo_M.pdf: 728894 bytes, checksum: a634cf10f92a568a1d7fcacc8a4c1797 (MD5) Previous issue date: 2008 / Resumo: Embora pouco seja conhecido sobre a contribuição de equipamentos médicos no custo de atenção à saúde, eles têm sido apontados como grandes responsáveis pelo aumento nas despesas do setor de saúde. Este trabalho apresenta um método para analisar o modo como os equipamentos médico-hospitalares (EMH) consomem recursos durante os procedimentos médicos e para estimar os custos desses recursos. Focalizando o procedimento médico, o método combina o sistema de custeio baseado em atividades direcionado por tempo (Time-Driven Activity-Based Costing, TDABC) e técnicas de cálculo do custo do ciclo de vida (Life-Cycle Cost) para avaliar o papel dos equipamentos médicos no processo de assistência à saúde. O método é composto de duas fases: (1) mapeamento da estrutura de consumo de recursos e (2) identificação e alocação dos custos dos recursos ao procedimento. O método só avalia os custos diretamente relacionados aos equipamentos (como acessórios, itens descartáveis e manutenção). Os resultados mostraram que a contribuição dos equipamentos no custo de um procedimento médico depende do modo que ele é usado em cada procedimento e das práticas específicas do hospital. / Abstract: Although little is known about the contribution of medical equipment to the cost of providing health care, they have been pointed out as major cause of the increase in the health sector expenditures. This study presents a method to analyze the way medical equipment consumes resources during medical procedures and to estimate the costs of these resources. Focusing the medical procedure, the method combines Time-Driven Activity-Based Costing (TDABC) and Life-Cycle Cost (LCC) techniques to evaluate the role of medical equipment in the process of delivering health care. The method is composed of two phases: (1) mapping of the resource consumption structure and (2) identification and allocation of resource costs to procedures. The method only evaluates the costs directly related to the equipment (such as accessories, disposables and maintenance). The results showed that the contribution of equipment to the cost of a medical procedure depends on the way it is used in each procedure and on the hospital's specific practices. / Mestrado / Engenharia Biomedica / Mestre em Engenharia Elétrica
37

Análise dos intervalos (R-R) entre monitor WCS Pulse e eletrocardiograma portátil porta PAK/90 / Analysis of the RR interval monitors WCS Pulse and comparison with porta Pak/90 electrocardiogram

Buck, Fabiano 24 June 2016 (has links)
Intervalos dos batimentos (R-R) vêm sendo considerado pela literatura, como um dos mais promissores meios de análise do sistema autônomo. Porém, diversos monitores e seus métodos, necessitam de validação através da análise dos parâmetros de VFC. O objetivo deste estudo foi validar um instrumento portátil, específico para mensuração dos intervalos dos batimentos (R-R) da marca WCS Pulse. Para a proposta deste estudo, 30 indivíduos do sexo masculino praticantes de Jiu-Jitsu, foram monitorados através de ECG e monitor WCS Pulse. Os parâmetros de VFC: intervalos (R-R), LF, HF e LF/HF foram coletados em pré- exercício, 24 e 48 horas após exercício. Conforme os resultados observados, os instrumentos ECG e WCS Pulse apresentam forte correlação e forte coeficiente de correlação intra-Classe, nos parâmetros de VFC (LF, HF e LF/HF). Por outro lado, quanto aos valores de Student t aplicados nos intervalos (R-R), foi observado diferença significativa entre os instrumentos (p<0.05) em todos os momentos da pesquisa. Através deste estudo, pode-se considerar que o monitor dos intervalos dos batimentos (R-R) da marca WCS Pulse é uma ferramenta de biomarcador (não invasivo) eficaz. Nesta esteira, o equipamento de monitoração dos intervalos (R-R) WCS Pulse, demonstrou um grau de concordância para a utilização em centros de treinamentos esportivos e ciências da saúde; porém, os parâmetros de resolução de amostragem do instrumento WCS Pulse, deve ser mais bem observado quando for comparado com instrumentos existentes no mercado e ou eletrocardiogramas. / The RR interval has been considered in the literature, the most promising analysis autonomous system. However, several monitors and validation methods is necessary through of the HRV parameters analysis. The aim of this study was, validate portable specific instrument to measurement RR interval WCS Pulse. For the proposal of this study, 30 male practitioners of BJJ were monitored through ECG and monitor Pulse WCS in different ways. The parameters of HRV: RR interval, LF, HF and LF / HF were collected in pre-exercise, 24 and 48 hours after exercise. Results: ECG instruments and WCS Pulse demonstrated strong correlation (r), and strong values to coefficient of intra-class in HRV parameters (LF, HF and LF / HF). In the other hand, the Student t values applied on the RR interval, was observed significant difference between the instruments in all moments of the research (p <0.05). Through this study, we consider that monitor RR interval WCS Pulse is effective biomarker tool (noninvasive). Thus, the equipment monitoring of RR intervals WCS Pulse, showed highs degree of agreements for use in sports training centers and Health Sciences; However, the instrument sampling resolution parameters, WCS Pulse should be more observed when compared to existing instruments in the market and electrocardiogram.
38

Elaboração de um guia para o uso do tensor de difusão em ressonância magnética para os profissionais da área

Brey, Andressa Caron 24 July 2014 (has links)
O imageamento por tensor de difusão (DTI) por ressonância magnética (RM) é um método de aquisição recente e de utilização bastante reduzida nos serviços que possuem equipamentos os softwares paro DTI. A partir desta situação notou-se a necessidade de um guia para os profissionais envolvidos RM; que servisse como fonte de consulta para auxiliar na aquisição do DTI. Para criação deste guia um referencial fez necessário e foi obtido apenas como norteador por meio de um questionário aplicado a profissionais que trabalham com RM, de uma clínica de Curitiba. Através do questionário foi possível levantar que conceitos e parâmetros o guia poderia explanar, notoriamente precisando dar ênfase aos parâmetros básicos da técnica, as formas de reconstrução dos dados e as formas de visualização. O guia foi montado explicando o processo de aquisição do DTI, os principais parâmetros envolvidos e os termos comuns aos exames desta natureza. Também foram elaboradas 15 perguntas frequentes sobre o DTI, com tabelas de consulta rápida. O resultado final é um guia de fácil manuseio e entendimento que visa auxiliar os profissionais da área a pesquisarem, apreenderem e utilizarem a técnica de imageamento por tensor de difusão. Apesar de pronto, existe ainda a necessidade de introduzir o guia e coletar sugestões e ainda aprimorar os questionamentos iniciais aos profissionais da área de modo a enriquecer o guia. / Diffusion tensor imaging (DTI) by magnetic resonance (MR) is a recent method of acquisition whose utilization has been fairly reduced in services that use equipment with DTI software. From this situation, one observed the need to develop a guide for professionals involved in MR, which would serve as a reference source to assist in the acquisition of DTI. In order to make this guide, a reference was necessary to be given a steer and it was obtained through a questionnaire administered to professionals who work with MRI in a clinic in Curitiba. Through the questionnaire, it was possible to raise the concepts and parameters the guide could explain, especially emphasizing technique basic parameters, forms of data reconstruction and visualization forms. The guide was made explaining the acquisition of DTI, the main parameters involved and the common terms for these kinds of tests. In addition, 15 commonly asked questions about the DTI were prepared with quick reference tables. The final result is an easy-to-understand guide which aims to help the area professionals to search, apprehend and use the diffusion tensor imaging technique. Although it is ready, there is the need to introduce the guide and collect suggestions, and still, improve the professionals’ early questions to enhance the guide.
39

Avaliação das emissões conduzidas e radiadas geradas por unidade eletrocirúrgica e sistema de iluminação com lâmpadas fluorescentes em equipamentos médicos

Moraes, Fábio Brignol de 16 December 2013 (has links)
Este trabalho apresenta um estudo sobre interferência eletromagnética, emissões radiada e conduzida, gerados pelo sistema de iluminação e pela unidade de eletrocirurgia (bisturi eletrônico) numa sala cirúrgica de um hospital da cidade de Pato Branco/PR. O trabalho consistiu em medidas de emissões conduzidas e radiadas de sistemas de iluminação fluorescentes em laboratório e de emissões conduzidas e radiadas “in loco” da unidade de eletrocirurgia. Além disso, foi feito estudo de referenciais sobre as normas, nacionais e internacionais, que incidem sobre estes dois sistemas. Como resultado do trabalho tem-se um panorama sobre a situação das emissões conduzidas e radiadas, pelos sistemas de iluminação fluorescente e unidade eletrocirúrgica utilizados no hospital. / This work presents a study on electromagnetic interference radiated and conducted emissions generated by the lighting system and the electrosurgery unit (eletric scalpel) in na operating room of a hospital in Pato Branco / PR. The work consisted of measurements of conducted and radiated emission of fluorescent lighting systems in the laboratory of conducted and radiated “in loco” electrosurgery unit emissions. Futhermore, a study was made of references on standarts, national and international, that focus on these two systems. Because of the work, has an overview on the situation of conducted and radiated emissions, the fluorecent lighting used in electrosurgical unit and hospital systems.
40

Análise dosimétrica em pediatria neonatal

Bunick, Ana Paula 31 March 2014 (has links)
Exames radiográficos do tórax são frequentemente solicitados para pacientes recém-nascidos internados na Unidade de Terapia Intensiva (UTI) Neonatal. Entretanto, as crianças são mais radiossensíveis quanto menor a idade que possuem e devido ao maior número de células em processo de replicação. Essa característica acaba despertando uma maior preocupação da comunidade científica em conhecer a dose de radiação a que são expostos esses pacientes pediátricos. Este trabalho descreve a metodologia aplicada para a execução de uma análise dosimétrica em pediatria neonatal no Hospital Infantil Pequeno Príncipe, em Curitiba. Inicialmente, o trabalho propõe a construção de um objeto simulador de um recém-nascido para consequentes medidas de dose de radiação recebida pelo paciente neonato, através do uso de TLDs (Dosímetros Termoluminescentes) para medidas de ESAK (Kerma-ar na Superfície de Entrada) sob a região torácica e medida de kerma-ar na profundidade do pulmão, na água, com o uso de uma câmara de ionização. Também foi avaliada a dose de radiação espalhada recebida pelo paciente internado próximo ao paciente examinado. Os resultados da pesquisa mostraram, em geral, níveis de dose abaixo dos valores de referência para as medidas de ESAK. Para as medidas de kerma-ar na profundidade do pulmão, os valores encontrados e comparados com cálculos de dose-órgão por meio de um software mostraram-se abaixo dos valores obtidos com os TLDs. As medidas de radiação espalhada mostraram que os pacientes próximos ao paciente examinado recebem uma pequena faixa de contribuição de dose durante os exames. / Chest radiographic examinations are frequently requested for newborn patients hospitalized in a Intensive Care Unit (ICU) Neonatal. However, children are more radiosensitive the younger they are and due to the higher number of cells in replication process. This feature arises greater concern in the scientific community to know the dose of radiation that these pediatric patients are exposed. This paper describes the methodology used for the implementation of a dosimetric analysis in neonatal pediatrics at the Children's Hospital Pequeno Príncipe, in Curitiba. Initially, the work proposes the construction of a phantom of a newborn to subsequent measurement of the radiation dose received by the neonate patient, through the use of TLDs (Thermoluminescent Dosimeters) for measures ESAK (Entrance Surface Air-Kerma) in the thoracic region and measure kerma-air in the deep lung, in water, with the use of an ionization chamber. The scattered radiation dose received by another patient near the patient under examination was also evaluated. The results showed, in general, dose levels below the reference values for the measures ESAK. For the kerma- air in the deep lung, and the values obtained compared to organ dose calculations through software is shown to be below the values obtained with TLDs. The measurements showed that the scattered radiation near the patient examined receive a small contribution of dose during examinations.

Page generated in 0.4735 seconds