• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 114
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 115
  • 115
  • 97
  • 94
  • 57
  • 56
  • 54
  • 34
  • 30
  • 26
  • 24
  • 23
  • 22
  • 21
  • 19
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

Influência da densidade tubular em diferentes profundidades dentinárias na estabilidade de união de cimentos de iônomero de vidro / Influence of tubular density in diferent dentin depths in bonding stability of glass ionomer cements

Silva, Aline Galvão dos Santos 19 February 2016 (has links)
O objetivo do estudo foi avaliar a influência da densidade tubular em diferentes profundidades dentinárias na estabilidade de união de dois cimentos de ionômero de vidro (CIV) de alta viscosidade. Vinte terceiros molares foram alocados em 6 grupos experimentais, de acordo com a profundidade da dentina - proximal, oclusal superficial ou oclusal profunda, e os CIVs - Fuji IX (GC Corp.) e Ketac(TM) Molar Easy Mix (3M/ESPE). Inicialmente os dentes foram cortados a fim de se obter fatias de aproximadamente 1 mm de espessura de dentina proximal, oclusal superficial e profunda. Em seguida, foi realizado uma análise topográfica das secções das diferentes superfícies e profundidades em microscopia confocal a laser (100X) para obtenção das médias da densidade tubular em cada profundidade. Cânulas de polietileno foram então posicionadas sobre as secções de dentina pré-tratadas e preenchidas pelos CIVs. Os espécimes foram armazenados em água destilada por 24 h e 12 meses a 37°C, em seguida foram submetidos ao ensaio de microcisalhamento (0,5 mm/min). Após o ensaio, foi realizada a análise do padrão de fratura em estereomicroscópio (400X). Os dados obtidos foram submetidos à Análise de Variância para dados repetidos, seguido do teste de Tukey (?=5%). Verificamos que a densidade dos túbulos dentinários, em diferentes profundidades de molares permanentes, é inversamente proporcional a resistência de união de cimentos de ionômero de vidro de alta viscosidade. Foi ainda observado em todos os grupos que a resistência de união após 24 horas é maior do que em 12 meses, indicando degradação da interface adesiva ao longo do tempo. / The aim of this study was to evaluate the influence of dentin tubule density of different depths in the bond stability of two high viscous glass ionomer cements (GIC). Twenty (third) molars were assigned into 6 experimental groups, according to the depth of dentin - proximal, superficial or deep occlusal occlusal and the GICs - Fuji IX (GC Corp.) and Ketac (TM) Molar Easy Mix (3M / ESPE). Initially, the teeth were cut to obtain slices approximately 1 mm thick for approximal, superficial and deep occlusal surfaces. Then it was performed a topographical analysis of sections of different depths surfaces and laser confocal microscopy (100X) to obtain averages of the tubular density at each depth. Polyethylene cannulae were then positioned on the pre-treated dentin sections and filled with GIC. The specimens were stored in distilled water for 24 h and 12 months at 37°C were then subjected to microshear bonding test (0.5 mm / min). After the test, a fracture analysis pattern was performed in stereomicroscope (400X). The data were submitted to ANOVA for repeated measures followed by the Tukey test (? = 5%). We found that the density of dentinal tubules at different depths of permanent molars, is inversely proportional to the bond strength of high viscosity glass ionomer cements. It was observed in all groups which bond strength after 24 hours is higher than in 12 months, indicating degradation of the interface over time.
42

Avaliação de cimentos de ionômero de vidro modificados por resina frente à incorporação de nanopartículas de vitrocerâmica bioativa / Resin modified glass ionomer cements evaluation with additional bioactive glass-ceramics nanoparticles

Freitas, Maria Cristina Carvalho de Almendra 31 May 2011 (has links)
Os materiais bioativos são materiais sintéticos que possuem superfícies ativas em que os minerais presentes em tecidos duros podem se ligar quimicamente. Há alguns estudos em Odontologia, onde partículas desses materiais foram incorporadas aos Cimentos de Ionômero de Vidro (CIVs) e Cimentos de Ionômero de Vidro modificados por resina (CIVMRs) com o objetivo de se obter bioatividade, e conseqüente remineralização dentária. O presente estudo teve como objetivo avaliar os efeitos da incorporação de nanopartículas de vitrocerâmica bioativa nas propriedades de resistência à compressão e rugosidade de CIVMRs. Fuji II LC e Vitremer foram considerados os grupos controles. Materiais experimentais foram feitos através da incorporação de 2, 5 e 10% em peso de Biosilicato nestes CIVMRs. Seis corpos-de-prova de cada material foram confeccionados para o teste de resistência à compressão, que foi realizado em máquina de ensaios universal (Emic), a uma velocidade de 1,0 mm/min, depois de mantidos por 24 horas em água destilada a 37°C. Para análise da rugosidade, foram confeccionados dois corpos-de-prova de cada material, armazenados em água destilada por sete dias, para terem suas superfícies analisadas por meio de Microscopia de Força Atômica. Os dados da resistência à compressão e rugosidade foram submetidos à análise estatística por meio da Análise de Variância (ANOVA) a dois critérios e para comparações múltiplas foi aplicado o teste de Tukey, com nível de significância de 5%. Apenas os cimentos com 2% de nanopartículas de vitrocerâmica bioativa obtiveram resistência à compressão semelhante ao grupo controle, as demais concentrações contribuíram para a diminuição dessa resistência. A incorporação de 5% de nanopartículas de vitrocerâmica bioativa aumentou a rugosidade superficial dos CIVMRs estudados. / Bioactive materials are synthetic materials that have active surfaces that are capable to chemically bond to dental structures. There are some studies where particles of these materials were incorporated in Glass-ionomer cements (GIC) and Resin-modified glass-ionomer cements (RMGIC) trying to achieve bioactivity and dental remineralization. The aim of this study was to evaluate the effects of the incorporation of bioactive glass-ceramics nanoparticles on the compressive strength and roughness of RMGIC. Fuji II LC and Vitremer were considered the control groups. Experimental materials were made adding 2, 5 and 10% (weight) of Biosilicate into these RMGIC. Six specimens of each material were made to be tested on compressive strength performed with a universal testing machine (Emic) at a crosshead speed of 1.0 mm / min, after they were stored in distilled water for 24 hour at 37°C. To roughness analysis, two specimens of each material were made and stored in distilled water for 7 days and their surfaces were analyzed with a Atomic Force Microscope. Data of compressive strength and roughness were statistically analyzed by ANOVA and Tukey test for multiple comparisons. Only the RMGICs with 2% of bioactive glass-ceramic nanoparticles obtained compressive strength similar to the control RMGICs, the other concentrations decreased their compressive strength values. The incorporation of 5% of bioactive glass-ceramic nanoparticles increased the roughness of the RMGICs.
43

Estudo comparativo da radiopacidade de materiais forradores / Comparative study of pulp capping materials\' radiopacity

Hamida, Hisham Mohamad 28 September 2007 (has links)
O sucesso no tratamento odontológico tem sido incansavelmente buscado, seja através da melhoria das técnicas ou dos materiais. Contribuindo com essa realidade, o objetivo deste trabalho foi, por meio de uma metodologia inédita, verificar e comparar a densidade óptica do hidróxido de cálcio, cimento de ionômero de vidro e de um vidro bioativo, correlacionando-as com a densidade óptica de estruturas dentais. Foi desenvolvido e confeccionado um dispositivo padronizador, que simula a situação clínica onde o material é utilizado, composta por orifícios, onde o material era depositado, e por degraus, que representavam as diferentes espessuras dos materiais, além do penetrômetro de alumínio, para que fosse obtida uma curva de padronização. Foram obtidas imagens radiográficas em tempos de exposição de 0,3; 0,4 e 0,5s. Após a leitura dos valores da densidadeópticas das imagens radiográficas em fotodensitômetro, os dados obtidos foram submetidos à análise estatística (teste 3-way ANOVA, Bonferroni, nível de significância de 95%) que permitiu verificar que houve diferença na densidade óptica dos materiais, tanto em tempo, quanto em espessuras diferentes, sejam comparados entre si ou com as estruturas dentais. Os maiores valores foram obtidos com o hidróxido de cálcio, no tempo de 0,5s com 2,0mm de espessura, enquanto que o menor valor foi apresentado pelo esmalte com 3,0mm em tempo de 0,3s. Com os resultados obtidos, concluiu-se que todos os materiais apresentaram valores menores que as estruturas dentais, sendo mais radiolúcidos. / The success of dental treatment has been continuously searched by the improvement of both the techniques and materials. In order to contribute with this reality, the purpose of this study was to verify and compare, by means of an inedited methodology, the optical densities of calcium hydroxide, glass ionomer cement and a bioactive glass, correlating them with the optical density dental tissues. A standardizing device was developed and constructed, which simulates the clinical situation in which the material is used. This device was composed of orifices in which the material was inserted and steps that represented the different thicknesses of the materials, in addition to an aluminum penetrometer to provide a standardization curve. Radiographic images were obtained using exposure times of 0.3, 0.4 and 0.5 s. After reading of the optical density values of the radiographic images in a photodensitometer, the gathered data were submitted to statistical analysis by 3-way ANOVA and Bonferroni correction at 5% significance level. There was statistically significant difference in the optical density of the material regarding both the exposure times and the thicknesses, comparing to each other as well as to the dental tissues. The greatest values were obtained for calcium hydroxide at 0.5-s exposure time and 2.0 mm thickness, whereas the lowest value was obtained for enamel with thickness of 3.0 mm and exposure time of 0.3 s. Based on the obtained results, it may be concluded that all materials presented lower optical density values than the dental structures, being more radiolucent, in addition to the suggestion of adding to the materials? instructions for use information regarding the ideal exposure time and type of x-ray equipment.
44

Influência do condicionamento da dentina na resistência de união de cimento de ionômero de vidro / Er,Cr:YSGG Laser Dentin Conditioning Influence on Glass Ionomer Cement Bond Strength

Garbui, Bruna Uglik 05 July 2012 (has links)
Objetivos: avaliar o efeito de 3 parâmetros de condicionamento da dentina utilizando o laser de Er,Cr;YSGG (2,78m) na resistência de união (RU) de cimento de ionômero de vidro convencional (CIV). Materiais e métodos: Foram utilizados neste estudo 68 terceiros molares humanos, divididos aleatoriamente em 4 grupos (n=17/ grupo): G1 (grupo controle): nenhum tipo de condicionamento; G2: condicionamento com laser de Er,Cr;YSGG 0,5W, 25mJ, 20Hz ou G3: 1,0W, 50mJ, 20Hz e G4: 1,5W, 75mJ, 20Hz. Dois dentes em cada um dos grupos foram observados em microscopia eletrônica de varredura (MEV) para identificar as características morfológicas dos diferentes condicionamentos de superfície realizados. Os outros 15 dentes/grupo, foram preparados para ensaio de RU, obtendo uma superfície plana de dentina onde foram construídos 3 (n=45/grupo) corpos de prova em forma de cilindro (1mm de diâmetro X 0,5mm de altura) utilizando o ionômero de vidro Ketac Molar Easymix- 3M ESPE. Após o armazenamento em água destilada por 24h a 37oC os espécimes foram ensaiados pelo teste de microcisalhamento. Os valores finais de resistência adesiva foram calculados e expressos em Mega Pascal (MPa). Os dados foram coletados e analisados por ANOVA (p<0,001). Resultados: Os espécimes do G2 apresentaram os maiores resultados de RU (10,50MPa ±0,84), seguido pelo G1 (4.77MPa ±0.59), G3 (3.32MPa ±0.39) e G4 (2,94MPa ±0,50) que não apresentaram diferença estatisticamente significante quanto comparados entre si. A análise em MEV do G1 mostrou camada de smear ao longo de toda a superfície de dentina, enquanto nos outros grupos observou-se túbulos dentinários abertos, característicos na irradiação com laser de Er,Cr:YSGG. Os pulsos do laser no G2 eram facilmente distinguidos, o que não acontecia nos grupos G3 e G4, sugerindo que parâmetros de energia maiores podem causar efeitos mais extensos à estrutura da dentina. Na análise do padrão de fratura, todos os grupos apresentaram maior porcentagem de fratura adesiva G1:73,3%, G2:48,9% G3:66,7% e G4:64,4%. O tipo de fratura mista foi proporcional ao aumento da RU (G1:24,4%, G2:46,7%, G3:20,0% e G4:17,8%). Conclusão: O condicionamento da dentina com o laser de Er,Cr:YSGG na potência de 0,5W aumentou significativamente a RU do CIV à dentina, enquanto os demais parâmetros testados reduziram a RU. / Objective: To evaluate the effect of 3 dentin conditioning parameters of Er,Cr:YSGG laser (2,78 m) on the bond strength (BS) of conventional glass ionomer cement (CGIC). Methods: A total of 68 third molars were divided into four groups and was subjected to one of the following pretreatments: G1- the control group, no pretreatment was realized; G2, G3 and G4 were pretreated with Er,Cr:YSGG laser irradiation at 0.5 W, 25 mJ, 9 J/cm2, and 20 Hz (G2); 1.0 W, 50 mJ, 18 J/cm2, and 20 Hz (G3); and at 1.5 W, 75 mJ, 27 J/cm2, and 20 Hz (G4). A scanning electron microscopy (SEM) evaluation (n=2) of pretreated dentine and a microshear bond strength test (n=15) were performed after 24h of water immersion. To build the specimens (each of which was 1 mm in diameter) for the microshear test, CGIC (Ketac Molar Easy Mix) was used. The data were analysed by one-way ANOVA (p<0.001). Results: The G2 specimens presented the highest BS results (10.50 MPa ± 0.84), and G1 had the next highest average BS values (4.77 MPa ± 0.59). G3 (3.32 MPa ± 0.39) and G4 (2.94 MPa ± 0.50) demonstrated the lowest BS values, although the BS difference between these groups was not statistically significant (p>0.001). The SEM analysis of G1 revealed that the smear layer covered the entire dentine surface, whereas in groups G2, G3, and G4, irregular dentine was detected that possessed the open dentinal tubules and protruded peritubular dentine that are the characteristic results of laser irradiation. Laser pulses could easily be distinguished in G2 but not in G3 and G4, suggesting that higher energy parameters can broadly disrupt dentine structure and thereby affect the bonding of dentine to GIC. Conclusion: Dentine pretreatment with an Er,Cr:YSGG laser at a power of 0.5 W increased the BS of conventional GIC.
45

Efeito da solução de clorexidina a 2% a um cimento ionomérico e um resinoso na adesão de pinos de fibra de vidro em raízes bovinas após 7 dias e 6 meses de armazenamento / Effect of 2% chlorhexidine solution on bonding of a glass ionomer cement and a resin cement to bovine root dentin after 7-day and 6-month storage

Araújo, Diana Ferreira Gadêlha de 08 March 2013 (has links)
Este trabalho avaliou a influência do uso de solução de clorexidina a 2% (CHX) na resistência de união de pino de fibra de vidro à dentina radicular, utilizando um agente cimentante ionomérico modificado por resina e um cimento resinoso dual com sistema adesivo convencional, nos terços cervical, médio e apical. Oitenta raízes bovinas foram selecionadas, cortadas em 17mm e tratadas endodonticamente para em seguida serem divididas em 8 grupos: ARC (RelyX ARC/ScothBond MultiPurpose- cimento resinoso); ARC+CHX (ARC associado a CHX); RL (RelyX Luting 2- ionômero de vidro); RL+CHX (RL associado a CHX). Os espécimes de cada protocolo foram divididos em grupos de 7 dias ou 6 meses de armazenamento, depois de serem restaurados com pino de fibra de vidro cônico Exacto. Após 24 horas da cimentação, as raízes foram seccionadas perpendicularmente ao longo eixo e identificadas quanto à região, obtendo-se fatias (1mm de espessura). Após o tempo de armazenamento proposto, todas as fatias foram submetidas ao teste de extrusão (push-out) com célula de carga a 0,5mm/min. Os dados foram tabelados considerando as variáveis dos diferentes agentes cimentantes, uso ou não de solução de clorexidina, terços radiculares e tempo de armazenamento. Depois de testados, todos os espécimes foram submetidos à análise dos tipos de fraturas encontradas. Os valores de resistência obtidos foram submetidos à análise estatística através do teste ANOVA a quatro critérios e comparações múltiplas com Tukey, ambos com p<0,05. Os valores obtidos para os grupos armazenados por 7 dias nos terços cervical, médio e apical, respectivamente, foram: ARC- 4,03 (1,85); 4,68 (2,76); 2,97 (1,56); ARC+CHX- 6,75 (3,01); 5,28 (2,89); 3,98 (3,40); RL- 2,26 (0,48); 1,97 (1,31); 1,69 (0,75); RL+CHX- 2,26 (0,96); 2,10 (0,93); 1,65 (1,40). Para os grupos armazenados por 6 meses, os valores resultantes foram: ARC- 6,57 (2,43); 6,56 (2,85); 5,15 (3,07); ARC+CHX- 3,23 (3,13); 1,75 (1,28); 3,26 (2,10); RL- 2,02 (1,13); 1,90 (1,33); 1,40 (1,43); RL+CHX- 1,06 (0,70); 0,78 (0,38); 0,88 (0,90). A análise das fraturas encontrou predominância de falhas adesivas entre cimento e dentina e mistas para os grupos cimentados com ARC. Grupos cimentados com RL apresentaram maioria de falhas do tipo mista e adesiva entre cimento e pino. Os cimentos apresentaram desempenho semelhante para o teste imediato, mas o ARC obteve melhor desempenho após 6 meses de armazenamento. A CHX não exerceu influência positiva para nenhuma das situações testadas. Não foram encontradas diferenças significantes entre os terços de um mesmo grupo. A resistência adesiva foi influenciada principalmente pelo tipo de cimento utilizado. / This study evaluated the influence of 2% chlorhexidine digluconate (CHX) on glassfiber post bonding strength to root dentin with a dual-cured resin cement and a resinmodified glass-ionomer cement, in terms of coronal, middle, and apical thirds. Eighty bovine roots were sectioned 17mm from their apices and endodontically treated and randomly assigned into eight groups: ARC (dual-cured resin cement RelyX ARC + ScothBond Multi Purpose adhesive system); ARC+CHX (ARC associated with CHX); RL (resin-modified glass-ionomer cement RelyX Luting 2) and RL+CHX (RL associated with CHX). Half of each group was subjected to either 7-day or 6-month storage in artificial saliva, after being restored with glass-fiber post Exacto. After 24 hours of luting, the roots were sliced under irrigation to obtain 1mm-thick slices. After the storage time, slices were subjected to push-out test with a universal test machine with a crosshead speed of 0.5mm/min. After this test, the slices were submitted to analysis of failure modes. Data of bond strength were submitted to four-way ANOVA and Tukeys tests (p&#x2264;0.05). The values of average and standard deviation (MPa) regarding coronal, middle, and apical thirds for 7-day groups were: ARC- 4.03 (1.85); 4.68 (2.76); 2.97 (1.56); ARC+CHX- 6.75 (3.01); 5.28 (2.89); 3.98 RL- 2.26 (0.48); 1.97 (1.31); (3.40); 1.69 (0.75); RL+CHX- 2.26 (0.96); 2,10 (0.93); 1.65 (1.40). After 6-month storage, the respectively values obtained were: ARC- 6.57 (2.43); 6.56 (2.85); 5.15 (3.07); ARC+CHX- 3.23 (3.13); 1.75 (1.28); 3.26 (2.10); 1.40 (1.43); RL- 2.02 (1.13); 1.90 (1.33); RL+CHX- 1.06 (0.70); 0.78 (0.38); 0.88 (0.90). The most observed failures were adhesive cement-dentin and mixed failures for ARC groups; for the RL groups, the main failures were adhesive cement-post and mixed modes. Immediate values showed similar performance between both tested cements. After 6 months, ARC yielded higher bond strength compared to RL. For any tested situation, CHX exhibited improved bond strength, disregarding neither luting cement nor time.
46

Estudo comparativo da radiopacidade de materiais forradores / Comparative study of pulp capping materials\' radiopacity

Hisham Mohamad Hamida 28 September 2007 (has links)
O sucesso no tratamento odontológico tem sido incansavelmente buscado, seja através da melhoria das técnicas ou dos materiais. Contribuindo com essa realidade, o objetivo deste trabalho foi, por meio de uma metodologia inédita, verificar e comparar a densidade óptica do hidróxido de cálcio, cimento de ionômero de vidro e de um vidro bioativo, correlacionando-as com a densidade óptica de estruturas dentais. Foi desenvolvido e confeccionado um dispositivo padronizador, que simula a situação clínica onde o material é utilizado, composta por orifícios, onde o material era depositado, e por degraus, que representavam as diferentes espessuras dos materiais, além do penetrômetro de alumínio, para que fosse obtida uma curva de padronização. Foram obtidas imagens radiográficas em tempos de exposição de 0,3; 0,4 e 0,5s. Após a leitura dos valores da densidadeópticas das imagens radiográficas em fotodensitômetro, os dados obtidos foram submetidos à análise estatística (teste 3-way ANOVA, Bonferroni, nível de significância de 95%) que permitiu verificar que houve diferença na densidade óptica dos materiais, tanto em tempo, quanto em espessuras diferentes, sejam comparados entre si ou com as estruturas dentais. Os maiores valores foram obtidos com o hidróxido de cálcio, no tempo de 0,5s com 2,0mm de espessura, enquanto que o menor valor foi apresentado pelo esmalte com 3,0mm em tempo de 0,3s. Com os resultados obtidos, concluiu-se que todos os materiais apresentaram valores menores que as estruturas dentais, sendo mais radiolúcidos. / The success of dental treatment has been continuously searched by the improvement of both the techniques and materials. In order to contribute with this reality, the purpose of this study was to verify and compare, by means of an inedited methodology, the optical densities of calcium hydroxide, glass ionomer cement and a bioactive glass, correlating them with the optical density dental tissues. A standardizing device was developed and constructed, which simulates the clinical situation in which the material is used. This device was composed of orifices in which the material was inserted and steps that represented the different thicknesses of the materials, in addition to an aluminum penetrometer to provide a standardization curve. Radiographic images were obtained using exposure times of 0.3, 0.4 and 0.5 s. After reading of the optical density values of the radiographic images in a photodensitometer, the gathered data were submitted to statistical analysis by 3-way ANOVA and Bonferroni correction at 5% significance level. There was statistically significant difference in the optical density of the material regarding both the exposure times and the thicknesses, comparing to each other as well as to the dental tissues. The greatest values were obtained for calcium hydroxide at 0.5-s exposure time and 2.0 mm thickness, whereas the lowest value was obtained for enamel with thickness of 3.0 mm and exposure time of 0.3 s. Based on the obtained results, it may be concluded that all materials presented lower optical density values than the dental structures, being more radiolucent, in addition to the suggestion of adding to the materials? instructions for use information regarding the ideal exposure time and type of x-ray equipment.
47

Efeito da escovação simulada sobre cimentos de ionômero de vidro indicados para tratamento restaurador atraumático

Thomassewski, Manoela Hass Dolinski 26 February 2008 (has links)
Made available in DSpace on 2017-07-24T19:22:05Z (GMT). No. of bitstreams: 1 MANOELA HASS DOLINSKI THOMASSEWSKI.pdf: 1885236 bytes, checksum: f6df4dd8ee0fdb0bea20dba5b9c53058 (MD5) Previous issue date: 2008-02-26 / The purpose of this study was to measure mass loss and surface roughness (Ra) changes of differents glass ionomer cement indicated to atraumatic restorative treatment, with a resin composite used as control material, after a simulated toothbrushing test. The surface characteristics before and after abrasion were evaluated on scanning electron microscopy (SEM). The tested materials were: Vitro Fil LC® ,Fuji IX® , Vitro Molar® , Maxxion R®, and the resin composite Filtek Z100®. Ten samples (6mm in diameter and 5mm thick) on all samples from each were prepared according to manufacturers’ instructions. Toothbrushing abrasion was performed on all specimens from each of the materials using a simulator. The mass loss, surface roughness and qualitative analyse were assessed before and after 20000 brushstrokes, using Shimadzu analytical balance of 0,0001g accuracy, a Mitutoyo surftest-301 and Shimadzu SSX-550 Superscan respectively. The measurements of both properties were statiscally compared by Anova one-way and then paired t-test and Tukey’s test. Correlation between mass loss and surface roughness was calculated. The level significance was α=5% (p<0,05). All materials presented a statistically significant mass loss comparing initial and final values. The loss mass in order decreasing was Vitro Fil LC>Maxxion R> Vitro Molar>Filtek Z100>Fuji IX. All materials became rougher with the exception of Vitro Molar that presented low roughness after toothbrushing test. There was no correlation between wear and surface roughness and SEM observations were in accordance to those roughness measured. In conclusion, the findings of this study showed that, the high viscosity glass cement ionomer presented wear and roughness seems to control material and the fluoride release propertie, this may be adequate for atraumatic restorative treatment. However, long-term clinical evaluation are necessary to better indicate this category of materials / O objetivo deste estudo foi mensurar a perda de massa e as alterações de rugosidade média superficial (Ra) de diferentes cimentos de ionômero de vidro indicados para tratamento restaurador atraumático tendo uma resina composta como material controle, após teste de escovação simulada. As características de superfície antes e após abrasão foram avaliadas em microscópio eletrônico de varredura (MEV). Os materiais testados foram: Vitro Fil LC® ,Fuji IX® , Vitro Molar® , Maxxion R®, e a resina composta microhíbrida Filtek Z100®. Dez amostras (6mm de diâmetro e 5mm de espessura) de cada material foram confeccionados de acordo com as instruções do fabricante. O teste foi conduzido em uma máquina de escovação simulada, em todas as amostras de todos os materiais, totalizando 20000 ciclos. Antes e após o teste, a massa, rugosidade e analise qualitativa em MEV, de cada material foram aferidas em um balança analítica Shimadzu de 0,0001g de precisão, pelo equipamento Mitutoyo modelo surftest-301 e pelo microscópio Shimadzu SSX-550 Superscan., respectivamente. Os resultados das variáveis perda de massa e rugosidade foram analisados pelo teste ANOVA de um critério e então o pós-teste para comparações múltiplas de Tukey, com o objetivo de identificar entre quais grupos situavam as diferenças. Para analisar a relação entre perda de massa e rugosidade média foi utilizada a análise de regressão linear. O nível de significância empregado foi de α=5% (p<0,05), utilizado para todas as análises. Todos os materiais apresentaram diferenças estatísticas de perda de massa entre valores iniciais e finais. A perda de massa em ordem decrescente foi Vitro Fil LC>Maxxion R> Vitro Molar>Filtek Z100>Fuji IX. Os materiais se tornaram mais rugosos exceto o Vitro Molar que apresentou menor rugosidade após teste. Não houve correlação entre perda de massa e rugosidade superficial. Observações ao MEV estavam de acordo com as medidas de rugosidade. Concluindo, os achados deste estudo mostraram que os cimentos de alta viscosidade apresentaram desgaste e rugosidade semelhantes ao material controle e ainda possuem a propriedade de liberar flúor, sendo adequado para tratamento restaurador atraumático. Entretanto, avaliações clínicas são necessárias para melhor indicar esta categoria de material.
48

O PAPEL DO CIMENTO DE IONÔMERO DE VIDRO EM DENTINA INFECTADA DE MOLARES PERMANENTES COM LESÕES PROFUNDAS DE CÁRIE TRATADOS PELA MÍNIMA INTERVENÇÃO

Kuhn, Eunice 12 December 2013 (has links)
Submitted by Angela Maria de Oliveira (amolivei@uepg.br) on 2018-09-11T12:32:26Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Eunice Kuhn.pdf: 3901142 bytes, checksum: 158e7cf48ebcd232e9b14c8bd538493c (MD5) / Made available in DSpace on 2018-09-11T12:32:26Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Eunice Kuhn.pdf: 3901142 bytes, checksum: 158e7cf48ebcd232e9b14c8bd538493c (MD5) Previous issue date: 2013-12-12 / Este estudo descreveu as alterações em dentina infectada de dentes permanentes antes e após selamento cavitário, bem como a influência do material restaurador nesse processo. Foram selecionados 45 molares com lesões de cárie profunda e ativa de 35 indivíduos com idades entre 7 a 15 anos. Critérios clínicos, radiográficos e laboratoriais foram utilizados para comparar as condições iniciais da dentina infectada, 60 dias e 10-15 meses após procedimento restaurador. O grupo experimental (G1) recebeu proteção pulpar com cimento de ionômero de vidro (CIV) e o grupo controle (G2), um material inerte (cera). As restaurações foram realizadas em resina composta. A cavidade foi dividida em duas porções equivalentes (mesial e distal) e fragmentos de dentina infectada foram removidos em dois momentos: inicial (porção mesial) e após 60 dias de selamento (porção distal). Os critérios clínicos utilizados foram a fluorescência da dentina infectada nos G1 e G2 (inicial e 60 dias) e a qualidade das restaurações (critérios USPHS) (inicial, 60 dias e 10-15 meses). Nos critérios laboratoriais, foram realizadas a análise ultraestrutural (MEV), mineral (MEV/EDS – cálcio, fósforo e flúor) e radiográfica (subtração radiográfica - 60 dias e 10 a 15 meses de selamento) para os dois grupos. A análise imunohistoquímica da dentina (expressões de MMP-2, MMP-8 e MMP-9) foi realizada para G1 (inicial e 60 dias). Os exames radiográficos consistiram de: radiografias periapicais (diagnóstico) e radiografias interproximais padronizadas (pós-restauração; aos 60 dias e 10-15 meses). Os dados referentes à fluorescência da dentina em G1 e G2 foram comparados com o teste Wilcoxon Signed Rank e em cada período com o teste de Mann-Whitney; o teste t pareado foi usado para verificar as diferenças em relação aos valores iniciais da porcentagem em peso do cálcio, fósforo e flúor entre os dois grupos após 60 dias e o teste de ANOVA e Tukey entre os dois grupos e tempos, bem como as variações radiográficas nos níveis de cinza ao longo do tempo. A intensidade e distribuição da imunomarcação nos dois momentos foi analisada pelo teste qui-quadrado. Os resultados mostraram que, após 60 dias de selamento cavitário, foram detectadas reduções significativas na fluorescência dentinária entre os períodos para ambos os grupos (p<0,05), melhor organização tecidual, com um arranjo mais compacto das fibrilas de colágeno e redução no número de bactérias, bem como um aumento significativo na porcentagem em peso de cálcio (p<0,001) e fósforo (p=0,003) para ambos os grupos. Para o flúor, nenhuma diferença significativa foi observada entre os grupos (p>0,05). Houve redução significativa para a expressão de MMP-8 após 60 dias de selamento cavitário (p=0,02). As MMPs localizaram-se de maneira generalizada na região intertubular em ambos os períodos (MMP-2 - p=0,172; MMP-8 - p=0,35; MMP-9 - p=0,28) e intratubular ausente ou localizada (p>0,28). Após 10-15 meses de acompanhamento, as restaurações mostraram-se clinicamente adequadas e a subtração radiográfica demonstrou que as médias dos tons de cinza em dentina sadia e cariada aumentaram (p<0,001), independente do grupo. Concluiu-se que o material de forramento colocado sobre dentina infectada não é fundamental para a paralisação do processo carioso; quando a cavidade é devidamente selada o tecido tende a se reorganizar num período curto de tempo (60 dias) sendo o processo de remineralização contínuo durante períodos mais longos. / This study described the changes in infected dentin in permanent teeth before and after cavity sealing, as well as the influence of lining material in this process. Forty five molars with deep and active caries lesions were selected, from patients aging 7 to 15 years old. Clinical, radiographic and laboratorial criteria were used to compare dentin conditions before and after 60-days and 10-15 months after dental restoration. The experimental group (G1) was lined with glass ionomer cement (GIC) and the control group (G2) with an inert material (wax). Composite resin was the selected restorative material for both groups. The caries cavities were divided into two equivalent portions (mesial and distal) and the dentin fragments were removed in two moments: baseline (mesial portion) and 60-days after restoration (distal portion). The clinical criteria for G1 and G2 were infected dentin fluorescence (baseline and 60- days) and the quality of the resin restorations (USPHS criteria) (baseline, 60-days and 10-15 months). For both groups, the laboratorial criteria were ultra structural (SEM), mineral (SEM/EDS - calcium, phosphorus and fluoride) and radiographic analysis (digital subtraction - 60-days and 10-15 months). The data from dentin fluorescence in G1 and G2 were analyzed by Wilcoxon Signed Rank test and in the different moments of evaluation with Mann-Whitney test. The paired Student's t test was used to verify differences in the percentage of weight of calcium, phosphorus and fluoride between groups after 60-days and the ANOVA and Tukey test between both groups and the moments of evaluation, as well as the radiographic changes in the gray levels along time. The intensity and distribution of immunostaining in both moments was analyzed with chi-square test. The results showed that, 60 days after restoration, there were significant reduction in dentin fluorescence in both groups (p<0.05), better tissue organization with a more compact fibril arrangement and a reduction in the number of bacteria, as well as a significant increase in the percentage in weight of calcium (p<0.001) and phosphorus (p=0.003) for both groups. No difference was observed in percentage of weight of fluorine (p>0.05). There was a significant reduction in the expression of MMP-8 60 days after restoration (p=0.02). The MMPs were generalized located in intertubular dentin in both evaluation moments ((MMP-2 - p=0.172; MMP-8 - p=0.35; MMP-9 - p=0.28) and in the intratubular dentin they were absence or localized (p>0.28). After 10-15 months, the resin restorations were judged clinically suitable and the digital subtraction of radiographic showed that the mean levels of gray tones incresead in sound and infected dentin (p<0.001) for both groups. It's possible to conclude that the lining material placed over infected dentin is not fundamental for caries arrestment; when the cavity is properly sealed, the tissue tends to reorganize in a short period of time (60 days) and the remineralization process continues for longer periods.
49

Influência da densidade tubular em diferentes profundidades dentinárias na estabilidade de união de cimentos de iônomero de vidro / Influence of tubular density in diferent dentin depths in bonding stability of glass ionomer cements

Aline Galvão dos Santos Silva 19 February 2016 (has links)
O objetivo do estudo foi avaliar a influência da densidade tubular em diferentes profundidades dentinárias na estabilidade de união de dois cimentos de ionômero de vidro (CIV) de alta viscosidade. Vinte terceiros molares foram alocados em 6 grupos experimentais, de acordo com a profundidade da dentina - proximal, oclusal superficial ou oclusal profunda, e os CIVs - Fuji IX (GC Corp.) e Ketac(TM) Molar Easy Mix (3M/ESPE). Inicialmente os dentes foram cortados a fim de se obter fatias de aproximadamente 1 mm de espessura de dentina proximal, oclusal superficial e profunda. Em seguida, foi realizado uma análise topográfica das secções das diferentes superfícies e profundidades em microscopia confocal a laser (100X) para obtenção das médias da densidade tubular em cada profundidade. Cânulas de polietileno foram então posicionadas sobre as secções de dentina pré-tratadas e preenchidas pelos CIVs. Os espécimes foram armazenados em água destilada por 24 h e 12 meses a 37°C, em seguida foram submetidos ao ensaio de microcisalhamento (0,5 mm/min). Após o ensaio, foi realizada a análise do padrão de fratura em estereomicroscópio (400X). Os dados obtidos foram submetidos à Análise de Variância para dados repetidos, seguido do teste de Tukey (?=5%). Verificamos que a densidade dos túbulos dentinários, em diferentes profundidades de molares permanentes, é inversamente proporcional a resistência de união de cimentos de ionômero de vidro de alta viscosidade. Foi ainda observado em todos os grupos que a resistência de união após 24 horas é maior do que em 12 meses, indicando degradação da interface adesiva ao longo do tempo. / The aim of this study was to evaluate the influence of dentin tubule density of different depths in the bond stability of two high viscous glass ionomer cements (GIC). Twenty (third) molars were assigned into 6 experimental groups, according to the depth of dentin - proximal, superficial or deep occlusal occlusal and the GICs - Fuji IX (GC Corp.) and Ketac (TM) Molar Easy Mix (3M / ESPE). Initially, the teeth were cut to obtain slices approximately 1 mm thick for approximal, superficial and deep occlusal surfaces. Then it was performed a topographical analysis of sections of different depths surfaces and laser confocal microscopy (100X) to obtain averages of the tubular density at each depth. Polyethylene cannulae were then positioned on the pre-treated dentin sections and filled with GIC. The specimens were stored in distilled water for 24 h and 12 months at 37°C were then subjected to microshear bonding test (0.5 mm / min). After the test, a fracture analysis pattern was performed in stereomicroscope (400X). The data were submitted to ANOVA for repeated measures followed by the Tukey test (? = 5%). We found that the density of dentinal tubules at different depths of permanent molars, is inversely proportional to the bond strength of high viscosity glass ionomer cements. It was observed in all groups which bond strength after 24 hours is higher than in 12 months, indicating degradation of the interface over time.
50

Efeito dos desafios erosivo ou erosivo/abrasivo sobre as estruturas dentárias adjacentes às restaurações realizadas com materiais contendo fluoreto ou cálcio / Effect of erosive and erosive/abrasive challenges on the dental hard tissues adjacent to restorations performed with materials containing fluoride or calcium

Viana, Ítallo Emídio Lira 29 January 2018 (has links)
Esse estudo avaliou in vitro o efeito dos desafios erosivo ou erosivo/abrasivo sobre materiais restauradores contendo fluoreto ou cálcio e sobre as estruturas dentárias adjacentes às restaurações realizadas com esses materiais. Fragmentos de esmalte e de dentina bovinos (4 mm × 4 mm × 2 mm), foram incluídos em resina acrílica e planificados. Uma cavidade padrão com dimensões 1,2 mm × 4 mm × 1,5 mm foi preparada nos espécimes, e restaurada de acordo com o material a ser testado: 1. Z350 - resina composta (Filtek Z350, 3M ESPE); 2. VB - compósito experimental contendo apenas vidros de bário; 3. DCPD30% - compósito experimental contendo 10% de vidros de bário e 30% partículas de fosfato di-cálcio di-hidratado (DCPD) funcionalizadas com dimetacrilato de dietilenoglicol (DEGDMA); 4. DCPD60% - compósito experimental contendo 60% partículas de DCPD funcionalizadas com DEGDMA; 5. Beautifil - GIOMER (Beautifil II, Shofu Dental Corporation); 6. Fuji IX - cimento de ionômero de vidro convencional de alta viscosidade (Fuji IX, GC Corporation); 7. Fuji II LC - cimento de ionômero de vidro modificado por resina (Fuji II LC, GC Corporation). Na sequência, os espécimes foram polidos e submetidos a dois tipos de tratamentos: erosão somente (n=10) ou erosão mais abrasão por escovação (n=10). A erosão foi realizada pela imersão dos espécimes em ácido cítrico a 0,3% (pH~2,6) por 5 min, seguido de 60 min de imersão em saliva artificial. Esse procedimento foi repetido 4×/dia, por 5 dias. A escovação foi realizada com uma suspensão de dentifrício padrão (Colgate Total 12 Mint Clean; 1450 ppm F-, como NaF) por 15 s (2 min de exposição total a suspensão de dentifrício), 2×/dia, 30 min após o primeiro e o quarto desafios erosivos. Ao final da ciclagem, a perda superficial (em ?m) do esmalte, da dentina e dos materiais restauradores foi determinada com um perfilômetro ótico. Para cada modelo (erosão e erosão-abrasão), os dados de perda superficial de esmalte, dentina e restauração foram analisados de maneira independente. Os dados foram analisados pelos testes de Kruskal-Wallis e Tukey. O nível de significância utilizado foi de 5%. No modelo de erosão, para esmalte, ambos cimentos ionoméricos apresentaram menor perda superficial do que o compósito Z350, apesar de Fuji II LC não ter se diferenciado significativamente dos grupos Beautifil e DCPD30%. Os outros grupos não foram diferentes de Z350 nem entre si. Para dentina, nenhum dos grupos foi diferente de Z350, com exceção de DCPD60%, o qual apresentou a maior perda superficial. Ambos cimentos ionoméricos apresentaram menor perda do que DCPD30%, Beautifil e DCPD60%. Em relação à restauração, os materiais Z350, Beautifil, VB, DCPD30% apresentaram perda superficial mínima, sem diferenças entre eles. Os cimentos ionoméricos apresentaram os maiores valores de perda, não se diferenciando de DCPD60%. No modelo erosão-abrasão, para esmalte, a menor perda superficial foi observada em Fuji II LC, sem diferença da Beautifil. Os outros grupos não se diferenciaram entre si nem da Beautifil. Para dentina, os grupos DCPD60%, Beautifil, Fuji II LC, Z350 e Fuji IX não se diferenciaram e, apresentaram menor perda superficial do que VB. Os cinco grupos citados também não foram diferentes de DCPD30%, com exceção de Fuji IX. Em relação à restauração, a maior perda foi observada para Fuji IX, sem diferenças de Fuji II LC e Beautifil. DCPD30%, Z350, VB e DCPD60% apresentaram valores mínimos de perda superficial, sem diferenças entre si. Concluiu-se que o cimento ionomérico Fuji II LC foi único capaz de proteger o esmalte adjacente à restauração contra desafios erosivos e erosivos/abrasivos, apesar de ter sido um dos materiais mais susceptíveis ao desgaste por ambos desafios. Para dentina, nenhum material exibiu efeito protetor. / This in vitro study evaluated the effect of erosive or erosive/abrasive challenges on restorative materials containing fluoride and calcium, and on the dental hard tissues adjacent to restorations performed with these materials. Enamel and dentin specimens (4 mm × 4 mm × 2 mm), obtained from bovine incisors, were embedded in acrylic resin, flattened and polished. In the specimens, a standard cavity of 1,2 mm × 4 mm × 1,5 mm was prepared and restored with the following materials: 1. Z350 - Composite resin without actives, Filtek Z350 (3MESPE); 2. VB - experimental composite containing barium glass only; 3. DCPD30% - experimental composite containing 10% of barium glass and 30% of DCPD particles functionalized with DEGDMA; 4. DCPD60% - experimental composite containing 60% of DCPD particles functionalized with DEGDMA; 5. Beautifil - GIOMER (Beautifil II, Shofu Dental Corporation); 6. Fuji IX - high viscosity glass ionomer (Fuji IX, GC Corporation); 7. Fuji II LC - resin-modified glass ionomer (Fuji II LC, GC Corporation). The specimens were polished again and then submitted to one of the two treatments: erosion only (n=10) or erosion plus toothbrushing abrasion (n=10). Erosion was performed by immersing the specimens in 0.3% citric acid solution (p~2.6), for 5 min, followed by 60 min exposure to artificial saliva. This procedure was repeated 4 times a day, for 5 days. Toothbrushing was performed with a slurry of a standard dentifrice (Colgate Total 12 Mint Clean; 1450 ppm F, as NaF), for 15 s (2 min total exposure time to the slurry), 2 times a day, 30 min after the first and last erosive challenges. At the end of cycling, enamel, dentin and restorative material surface loss (in ?m) were determined by optical profilometry. Data were analyzed by the Kruskal-Wallis and Tukey tests. The level of significance was 5%. In the erosion model, for enamel, both ionomeric cements presented lower surface loss than the Z350, although Fuji II LC did not differ significantly from Beautifil and DCPD30% groups. The other groups were no different from Z350 and from each other. For dentin, none of the groups were different from Z350, except for DCPD60%, which presented the highest surface loss. Both ionomeric cements presented lower loss than DCPD30%, Beautifil and DCPD60%. Regarding the restoration, the materials Z350, Beautifil, VB, DCPD30% showed minimal surface loss, with no differences between them. The ionomeric cements had the highest loss values, not differing from DCPD60%. In the erosion-abrasion model, for enamel, the lowest loss was observed for Fuji II LC, with no difference to Beautifil. The other groups showed no difference among them and from Beautifil. For dentin, the groups DCPD60%, Beautifil, Fuji II LC, Z350 and Fuji IX were no significant different and presented lower loss than VB. These five groups were also no different from DCPD30%, except Fuji IX. Regarding the restoration, the highest loss was observed for Fuji IX, with no difference from Fuji II LC and Beautifil. DCPD30%, Z350, VB and DCPD60% presented minimum values of surface loss, without differences between them. It was concluded that Fuji II LC ionomeric cement was the only material able to protect the enamel adjacent to the restoration against erosive and erosive/abrasive challenges, although it was one of the materials that was most susceptible to be wear off by both challenges. For dentin, no material exhibited a significant protective effect.

Page generated in 0.0593 seconds