• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • Tagged with
  • 14
  • 14
  • 12
  • 9
  • 9
  • 7
  • 3
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Comparação entre matriz dérmica acelular suína (Mucoderm®) versus tecido conjuntivo no tratamento de recessões gengivais múltiplas associadas à lesão cervical não-cariosa parcialmente restaurada : estudo clínico randomizado /

Rossato, Amanda January 2019 (has links)
Orientador: Mauro Pedrine Santamaria / Resumo: Estudos clínicos avaliaram diferentes opções de tratamento cirúrgico-restaurador para tratar recessões unitárias associadas à LCNC. No entanto, apesar de serem um achado comum, evidências insuficientes estão disponíveis na literatura a respeito do tratamento de recessões múltiplas associadas à LCNC e o protocolo clínico ideal para o tratamento deste tipo de lesões ainda não foi estabelecido. Dessa forma, o objetivo do presente estudo foi comparar dois protocolos multidisciplinares distintos por meio de um estudo clínico controlado e randomizado. Para tal, foram tratados 40 pacientes portadores de recessões múltiplas associadas à LCNC, os quais foram alocados aleatoriamente em um dos seguintes grupos: grupo teste (n=20), restauração parcial da lesão cervical e retalho posicionado coronariamente modificado associado ao enxerto de matriz dérmica acelular de origem suína (MCAF+PR+XDM) e grupo controle (n=20), restauração parcial da lesão cervical e retalho posicionado coronariamente modificado associado ao enxerto de tecido conjuntivo subepitelial (MCAF+PR+CTG). Após 6 meses, as taxas de recobrimento radicular foram 71,2% (2.5±1.1mm) para MCAF+PR+CTG e 59,7% (2±1.3mm) para MCAF+PR+XDM (p=0,1). MCAF+PR+CTG apresentou maior ganho de tecido queratinizado (p<0,05). MCAF+PR+XDM resultaram em menor dor pós-operatória e menor tempo de cirurgia (p=0,001). Ambos os grupos resultaram em melhorias na estética, sem diferença entre os grupos (p>0,05). Por conseguinte, dentro das limitações do... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Clinical studies assessed different surgical-restorative treatment options to lead to single recessions associated with NCCL. However, although they are a common finding, insufficient evidence is available in the literature concerning about the treatment of multiple adjacent gingival recessions associated with non-carious cervical lesions and the optimal clinical protocol for the treatment of these lesions has not been established. Thus, the aim of this study was to compare two different multidisciplinary protocols by means of a randomized controlled clinical trial. For such purpose, forty patients with multiple adjacent gingival recessions associated with NCCL were enrolled and randomly allocated to one of the following groups: test group (n=20), partial restoration of cervical lesion and modified coronally advanced flap for root coverage associated with porcine acellular dermal matrix (MCAF+PR+XDM) and control group (n=20), partial restoration of cervical lesion and modified coronally advanced flap associated with connective tissue graft (MCAF+PR+CTG). After 6 months, CD coverage rates were 71,2% (2.5±1.1mm) for MCAF+PR+CTG and 59,7% (2±1.3mm) for MCAF+PR+XDM (p=0,1). MCAF+PR+CTG resulted in greater gain of keratinized tissue (p<0,05). MCAF+PR+XDM resulted in lower postoperative pain and shorter surgical time (p=0,001). Within the limitations of the present study, both groups resulted in esthetic improvements (p>0,05). MCAF +PR + CTG and MCAF+PR+XDM were effective to treat ... (Complete abstract click electronic access below) / Mestre
2

Influência do tamanho da partícula, do jateamento prévio à sinterização e do envelhecimento na resistência mecânica de uma zircônia estabilizada por ítria /

Martins, Samira Branco. January 2018 (has links)
Orientador: Renata Garcia Fonseca / Resumo: Pouco se sabe sobre o efeito do jateamento pré-sinterização da zircônia na sua resistência mecânica, sob condições de envelhecimento. Este estudo avaliou a influência do tamanho da partícula, do momento do jateamento e do envelhecimento na resistência mecânica de uma zircônia estabilizada por ítria. Quatrocentos discos de uma zircônia estabilizada por ítria pré-sinterizados foram alocados como segue: sem jateamento; jateamento com partículas de óxido de alumínio (Al2O3) de 50 µm ou 120 µm antes (50/PRÉ ou 120/PRÉ) ou após (50/PÓS ou 120/PÓS) sua sinterização. Os discos foram não envelhecidos (24h) ou envelhecidos por: ciclagem mecânica (CM); envelhecimento hidrotérmico (EH) ou CM+EH, totalizando 20 grupos (n=20). Os espécimes foram submetidos ao teste de resistência à flexão biaxial (RFB) e, posteriormente, foram analisados fractograficamente. A análise de difração de raios-X (DRX) foi realizada em determinadas condições para caracterizar cristalograficamente o efeito do jateamento na zircônia. Os dados de RFB (MPa) foram analisados por ANOVA a 3 fatores e pós teste de Games Howell (α=0,05). Também foi realizada análise de Weibull. A RFB e a resistência característica (σ0) dos grupos 120/PÓS, envelhecidos ou não, foram significativamente maiores que as dos demais grupos jateados, e estatisticamente similares ou maiores que as dos respectivos grupos sem jateamento. Em contrapartida, o grupo 120/PRÉ/não envelhecido e todos os grupos 50/PRÉ apresentaram os menores valores. Em to... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Little is known about the effect of air-abrasion before zirconia sintering on its strength, under aging challenge. This study aimed to verify the influence of the airabrasion moment (before or after zirconia sintering), particle size (50 or 120 µm) and aging on the mechanical strength of a Y-TZP ceramic. Four hundred pre-sintered zirconia discs were allocated as follows: non-air-abraded; air-abraded with 50 µm or 120 µm Al2O3 particles before (50/BS or 120/BS) or after sintering (50/AS or 120/AS). The discs were non-aged (24h) or aged by: mechanical cycling (MC); hydrothermal aging (HA) or by both methods (MC+HA), totaling 20 groups (n=20). Specimens were subjected to biaxial flexural strength test (BFS). Fractographic analysis was performed to identify the fracture origin. The X-ray diffraction analysis (XRD) was performed under certain conditions to characterize the crystallographic effect of airabrasion on the zirconia. The BFS data (MPa) were analyzed by ANOVA and Games Howell post hoc test (α=.05). Weibull statistics was also applied. The BFS and the characteristic resistance (σ0) of the 120/AS groups, aged or not, were significantly higher than those of the other air-abraded groups, and statistically similar or higher than the respective groups without air-abrasion. In contrast, the 120/BS/non-aged group and all those 50/BS presented the lowest values. In all groups, the initial defect had its origin on the tensile stress side. Neither air-abrasion nor aging (except for 50/AS/MC+HA) reduced the zirconia reliability compared with the respective controls. Air-abrasion promotes an increase in the monoclinic phase content, while sintering zeroed this phase. Air-abrasion before zirconia sintering yields worse performance for BFS than after sintering, under aging challenges. The BFS and σ0 were strongly determined by the particle size and air-abrasion moment / Doutor
3

Influência do tamanho das partículas de óxido de alumínio, utilizadas com o sistema de abrasão a ar, no preparo cavitário, na microinfiltração e na resistência de união de restaurações de resina composta

Motisuki, Cristiane [UNESP] 29 August 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:33:01Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-08-29Bitstream added on 2014-06-13T18:44:49Z : No. of bitstreams: 1 motisuki_c_dr_arafo.pdf: 409791 bytes, checksum: c1d6a056e5d6c055cfca7b901317f0ff (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do presente estudo foi determinar qual tamanho de partícula de óxido de alumínio, utilizado em sistema de abrasão a ar, remove maior quantidade de dentina cariada, preservando o máximo de estrutura hígida. Superfícies de dentina foram obtidas a partir de secções longitudinais de 30 terceiros molares isentos de cárie. Em uma das metades foi realizada a indução de cárie artificial (Grupo C), enquanto a outra permaneceu hígida (Grupo H). Os espécimes do Grupo H (dentina hígida) e os espécimes do Grupo C (dentina cariada) foram divididos aleatoriamente em 3 subgrupos cada, de acordo com o tamanho de partícula empregada (27, 50 e 125æm). A ponta do aparelho (Microetcher II) foi posicionada perpendicularmente e a 1 mm da superfície dentinária, sendo o jato abrasivo aplicado durante 15 segundos. A pressão de ar comprimido foi regulada para 70 psi. A profundidade e a largura das cavidades foram medidas em fotomicrografias obtidas em MEV. A aplicação da análise de Variância e do teste de Tukey aos dados obtidos, revelaram que as partículas de 27 e 50mm foram capazes de remover maior quantidade de tecido cariado e menor quantidade de dentina hígida, quando comparadas às partículas de 125æm, sendo mais recomendadas para um tratamento conservador das lesões de cárie.
4

Influência do tamanho da partícula, do jateamento prévio à sinterização e do envelhecimento na resistência mecânica de uma zircônia estabilizada por ítria / Influence of particle size, air-abrasion before sintering and aging on yttria stabilized zirconia mechanical strength

Martins, Samira Branco 03 August 2018 (has links)
Submitted by Samira Branco Martins (samirabmartins@foar.unesp.br) on 2018-08-30T19:44:38Z No. of bitstreams: 1 TESE DOUTORADO SAMIRA .pdf: 933881 bytes, checksum: 1ebe4097c1b2d6665a4be82cc94f2dfa (MD5) / Rejected by Marley Cristina Chiusoli Montagnoli (marley@foar.unesp.br), reason: Por favor, fazer as seguintes correções: - inserir a ficha catalográfica no arquivo de sua tese; - quando for preencher metadados, preencher o campo Agência de fomento. on 2018-09-04T12:52:59Z (GMT) / Submitted by Samira Branco Martins (samirabmartins@foar.unesp.br) on 2018-09-06T18:29:33Z No. of bitstreams: 1 TESE DOUTORADO SAMIRA .pdf: 1082516 bytes, checksum: 012f9fe0b3e970650b71802c977af92d (MD5) / Rejected by Marley Cristina Chiusoli Montagnoli (marley@foar.unesp.br), reason: A ficha catalográfica está fora do padrão. Quando for inserir no seu arquivo observar em opções de colagem e escolher a opção que não desconfigure a sua ficha. Qualquer dúvida procure a Biblioteca de sua unidade. on 2018-09-06T19:06:06Z (GMT) / Submitted by Samira Branco Martins (samirabmartins@foar.unesp.br) on 2018-09-06T20:03:50Z No. of bitstreams: 1 TESE DOUTORADO SAMIRA.pdf: 939079 bytes, checksum: 5d37e78b11c143842a751fbaf6498aa2 (MD5) / Approved for entry into archive by Marley Cristina Chiusoli Montagnoli (marley@foar.unesp.br) on 2018-09-10T17:35:24Z (GMT) No. of bitstreams: 1 martins_sb_dr_arafor.int.pdf: 879795 bytes, checksum: 35bf73c7fbec804a07b0b28fe05ae668 (MD5) / Made available in DSpace on 2018-09-10T17:35:24Z (GMT). No. of bitstreams: 1 martins_sb_dr_arafor.int.pdf: 879795 bytes, checksum: 35bf73c7fbec804a07b0b28fe05ae668 (MD5) Previous issue date: 2018-08-03 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Pouco se sabe sobre o efeito do jateamento pré-sinterização da zircônia na sua resistência mecânica, sob condições de envelhecimento. Este estudo avaliou a influência do tamanho da partícula, do momento do jateamento e do envelhecimento na resistência mecânica de uma zircônia estabilizada por ítria. Quatrocentos discos de uma zircônia estabilizada por ítria pré-sinterizados foram alocados como segue: sem jateamento; jateamento com partículas de óxido de alumínio (Al2O3) de 50 µm ou 120 µm antes (50/PRÉ ou 120/PRÉ) ou após (50/PÓS ou 120/PÓS) sua sinterização. Os discos foram não envelhecidos (24h) ou envelhecidos por: ciclagem mecânica (CM); envelhecimento hidrotérmico (EH) ou CM+EH, totalizando 20 grupos (n=20). Os espécimes foram submetidos ao teste de resistência à flexão biaxial (RFB) e, posteriormente, foram analisados fractograficamente. A análise de difração de raios-X (DRX) foi realizada em determinadas condições para caracterizar cristalograficamente o efeito do jateamento na zircônia. Os dados de RFB (MPa) foram analisados por ANOVA a 3 fatores e pós teste de Games Howell (α=0,05). Também foi realizada análise de Weibull. A RFB e a resistência característica (σ0) dos grupos 120/PÓS, envelhecidos ou não, foram significativamente maiores que as dos demais grupos jateados, e estatisticamente similares ou maiores que as dos respectivos grupos sem jateamento. Em contrapartida, o grupo 120/PRÉ/não envelhecido e todos os grupos 50/PRÉ apresentaram os menores valores. Em todos os grupos, o defeito inicial se originou na superfície submetida à tração. Nem o jateamento, nem o envelhecimento (exceto o grupo 50/PÓS/CM+EH) reduziram a confiabilidade da zircônia em relação à dos respectivos grupos controles. O jateamento promoveu um aumento do conteúdo de fase monoclínica, enquanto a sinterização zerou essa fase. O jateamento da zircônia antes da sinterização teve pior desempenho para RFB em comparação ao realizado após sua sinterização, sob os meios de envelhecimentos. A RFB e σ0 foram fortemente determinadas pelo tamanho da partícula e pelo momento do jateamento, enquanto o envelhecimento agiu apenas quando a zircônia foi jateada antes da sinterização. / Little is known about the effect of air-abrasion before zirconia sintering on its strength, under aging challenge. This study aimed to verify the influence of the air-abrasion moment (before or after zirconia sintering), particle size (50 or 120 μm) and aging on the mechanical strength of a Y-TZP ceramic. Four hundred pre-sintered zirconia discs were allocated as follows: non-air-abraded; air-abraded with 50 μm or 120 μm Al2O3 particles before (50/BS or 120/BS) or after sintering (50/AS or 120/AS). The discs were non-aged (24h) or aged by: mechanical cycling (MC); hydrothermal aging (HA) or by both methods (MC+HA), totaling 20 groups (n=20). Specimens were subjected to biaxial flexural strength test (BFS). Fractographic analysis was performed to identify the fracture origin. The X-ray diffraction analysis (XRD) was performed under certain conditions to characterize the crystallographic effect of air-abrasion on the zirconia. The BFS data (MPa) were analyzed by ANOVA and Games Howell post hoc test (α=.05). Weibull statistics was also applied. The BFS and the characteristic resistance (σ0) of the 120/AS groups, aged or not, were significantly higher than those of the other air-abraded groups, and statistically similar or higher than the respective groups without air-abrasion. In contrast, the 120/BS/non-aged group and all those 50/BS presented the lowest values. In all groups, the initial defect had its origin on the tensile stress side. Neither air-abrasion nor aging (except for 50/AS/MC+HA) reduced the zirconia reliability compared with the respective controls. Air-abrasion promotes an increase in the monoclinic phase content, while sintering zeroed this phase. Air-abrasion before zirconia sintering yields worse performance for BFS than after sintering, under aging challenges. The BFS and σ0 were strongly determined by the particle size and air-abrasion moment, while aging acted only when the zirconia was air-abraded before sintering.
5

Influência do tamanho das partículas de óxido de alumínio, utilizadas com o sistema de abrasão a ar, no preparo cavitário, na microinfiltração e na resistência de união de restaurações de resina composta /

Motisuki, Cristiane. January 2005 (has links)
Orientador: Lourdes Aparecida Martins dos Santos-Pinto / Banca: Maria Cristina Borsatto / Banca: Regina Maria Puppin Rontani / Banca: Angela Cristina Cilense Zuanon / Banca: Carlos Alberto dos Santos Cruz / Resumo: O objetivo do presente estudo foi determinar qual tamanho de partícula de óxido de alumínio, utilizado em sistema de abrasão a ar, remove maior quantidade de dentina cariada, preservando o máximo de estrutura hígida. Superfícies de dentina foram obtidas a partir de secções longitudinais de 30 terceiros molares isentos de cárie. Em uma das metades foi realizada a indução de cárie artificial (Grupo C), enquanto a outra permaneceu hígida (Grupo H). Os espécimes do Grupo H (dentina hígida) e os espécimes do Grupo C (dentina cariada) foram divididos aleatoriamente em 3 subgrupos cada, de acordo com o tamanho de partícula empregada (27, 50 e 125æm). A ponta do aparelho (Microetcher II) foi posicionada perpendicularmente e a 1 mm da superfície dentinária, sendo o jato abrasivo aplicado durante 15 segundos. A pressão de ar comprimido foi regulada para 70 psi. A profundidade e a largura das cavidades foram medidas em fotomicrografias obtidas em MEV. A aplicação da análise de Variância e do teste de Tukey aos dados obtidos, revelaram que as partículas de 27 e 50mm foram capazes de remover maior quantidade de tecido cariado e menor quantidade de dentina hígida, quando comparadas às partículas de 125æm, sendo mais recomendadas para um tratamento conservador das lesões de cárie. / Doutor
6

Efeito do tratamento da superfície, ciclagem térmica e fadiga mecânica na resitência de união entre uma cerâmica reforçada por dissilicato de lítio e em cimento resinoso / Effect of surface treatments, thermocycling and loading on the bond between a ceramic and a resin cement

Guarda, Guilherme Bottene, 1987- 18 August 2018 (has links)
Orientadores: Lourenço Correr Sobrinho, Mário Alexandre Coelho Sinhoreti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T00:18:54Z (GMT). No. of bitstreams: 1 Guarda_GuilhermeBottene_M.pdf: 2504078 bytes, checksum: 72f1d754db2ac04524c40271b35d7366 (MD5) Previous issue date: 2011 / Resumo: O objetivo neste estudo foi investigar o efeito de diferentes tratamentos de superfície, fadiga mecânica e termociclagem na resistência da união à microtração da cerâmica IPS e.max (Ivoclar) e do cimento resinoso de ativação dupla. Métodos: 18 blocos de cerâmica (10 mm de comprimento x 7 mm de largura x 3 mm de espessura) foram confeccionados e divididos em 6 grupos (n=3): Grupos 1, 2 e 3 - jateamento por 5 segundos com partículas de óxido de alumínio de 50?m; Grupos 4, 5 e 6 - condicionamento com acido hidrofluorídrico à 10% por 20 segundos. O silano Rely X Ceramic Primer foi aplicado sobre todos os espécimes e seco por 5 minutos. Após, os blocos de cerâmica foram unidos à blocos de compósito restaurador Tetric N-Ceram (Ivoclar-Vivadent) com cimento resinoso RelyX ARC (3M ESPE), sob carga estática de 500 gf por 2 minutos. O excesso de cimento foi removido com micropincel e fotoativado por 160 segundos (40 s cada face) com um aparelho de LED (UltraLume 5, Ultradent). Os espécimes dos grupos 1 e 4 foram armazenados em água destilada a 37°C por 24 h. Nos grupos 2 e 5, os espécimes foram submetidos a 3.000 ciclos térmicos entre 5°C e 55°C. Para os grupos 3 e 6, os espécimes foram submetidos ao ensaio de fadiga mecânica por 100.000 ciclos com 2 Hz. Os espécimes foram seccionados perpendiculares a área de união para obtenção de palitos com área seccional de 1mm2 (25 palitos por grupo) e submetidos ao ensaio de resistência de união à microtração em máquina de teste universal (EZ Test - Shimadzu) com velocidade de 0,5 mm/min. Foi utilizado para verificar o padrão de fratura uma lupa estereoscópica (Olympus) com aumento de 40x. Os dados foram submetidos à Análise de Variância de 2 fatores e ao teste de Tukey (p<0,05). Os valores de resistência de união à microtração (MPa) foram: 26,9 ± 6,9, 22,2 ± 7,8 e 21,2 ± 9,1 para os Grupos 1 a 3 e 35,0 ± 9,6, 24,3 ± 8,9 e 23,9 ± 6,3 para os Grupos 4 a 6. O grupo controle submetido ao teste de fadiga e termociclado mostrou predominância de padrão de fratura adesiva para o tratamento de superfície com acido hidrofluorídrico a 10% e padrões adesiva e mista para tratamento de superfície com 50um de oxido de alumínio. Concluindo a fadiga e a termociclagem diminuíram significantemente a resistência de união à microtração para ambos os tratamentos de superfície das cerâmicas comparada ao grupo controle. Condicionamento com acido hidrofluorídrico a 10% aumentou a resistência de união à microtração para o grupo controle / Abstract: The aim of this study was to investigate the effect of surface treatments, mechanic fatigue and thermocycling tested on the microtensile bond strength of the ceramic IPS e.max Press (Ivoclar Vivadent) luted with dual-cured resin cement. Eighteen ceramic bars (10mm length x 7mm width x 3.0mm thickness) were fabricated, and divided into 6 groups (n=3): Groups 1, 2 and 3 - air particle abraded for 5 s with 50?m aluminum oxide particles; Groups 4, 5 and 6 - acid etched with 10% hydrofluoric acid for 20 s. Coupling agent silane was applied on to all bond surface specimens and allowed to dry for 5 s and the ceramic bars were bonded to a block of composite resin Tetric N-Ceram (Ivoclar-Vivadent) with Rely X ARC (3M ESPE) resin cement and placed under a 500 g static load for 2 min. The cement excess was removed with a disposable microbrush and 40 s light-activation (four activations) were performed using a LED curing unit (UltraLume LED 5, Ultradent). The specimens of the groups 1 and 4 were stored in distilled water at 37°C for 24 hours, groups 2 and 5 were submitted to 3,000 thermocycles between 5°C and 55°C and groups 3 and 6 submitted to a fatigue test for 100,000 cycles with 2 HZ. Specimens were sectioned perpendicular to the bonding area to obtain 1mm2 sectional area beams (25 beams per group) and submitted to a microtensile bond strength test in a universal testing machine (EZ Test - Shimadzu), at a crosshead speed of 0.5mm/min. The fracture specimens were observed under optical microscopy (Olympus) at a 40x magnification. Data were submitted to ANOVA and Tukey's test (p?0.05). Results: The microtensile bond strength values (MPa) were: 26.9 ± 6.9, 22.2 ± 7.8 and 21.2 ± 9.1 for G1-G3 and 35.0 ± 9.6, 24.3 ± 8.9 and 23.9 ± 6.3 for G4-G6. The control group, fatigue tested and thermocycled groups showed a predominance of failure adhesive for surface treatment with 10% hydrofluoric acid and adhesive and mixed for surface treatment with 50 ?m Al2O3. In conclusion the fatigue and thermocycling decreased significantly the microtensile bond strength for both ceramic surface treatments compared to control groups. Etching with 10% hydrofluoric acid increased the microtensile bond strength for the control group / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
7

Avaliação da superfície do esmalte após diferentes tempos de jateamento de óxido de alumínio indicados para a colagem de braquetes / Evaluation of enamel surface after different times of aluminium oxide sandblasting indicated for bracket bonding

Gabarrone, Lilian Rocha 01 July 2016 (has links)
Objetivo: avaliar e comparar os efeitos do jato de óxido de alumínio sobre a superfície do esmalte, quando aplicados por tempos diferentes. Material e métodos: 110 pré-molares foram obtidos por meio de doações do Banco de Dentes da FOUSP. Os dentes foram divididos aleatoriamente em 5 grupos (n=22) para a aplicação de jato de óxido de alumínio por diferentes períodos de tempo. Nos grupos A, B, C, D e E o jato de óxido de alumínio de 50 ?m foi aplicado, respectivamente, por 01, 03, 05, 07 e 10 segundos. Avaliações quantitativas da superfície do esmalte foram realizadas pelas análises das alterações do perfil e da rugosidade (Sa) da superfície vestibular antes e após o seu jateamento, por meio do medidor de perfil Form Talysurf Intra (Taylor Hobson - AMETEK Inc, Pennsylvania) e do interferômetro a laser Talysurf CCl Lite (Taylor Hobson - AMETEK Inc, Pennsylvania), respectivamente. Uma avaliação qualitativa da superfície do esmalte foi realizada por meio da microscopia eletrônica de varredura (MEV). Para esta última análise, um exemplar de cada grupo foi selecionado aleatoriamente para que as superfícies de esmalte jateadas fossem devidamente preparadas para as suas leituras. Os dados quantitativos foram comparados pelo teste ANOVA, seguido do teste post hoc de Tukey, adotando-se um nível de significância de 5% (p= 0,05). Resultados: observou-se maior alteração do perfil e da rugosidade conforme se aumentou o tempo de aplicação do jato de óxido de alumínio. Porém, com relação à alteração do perfil, diferenças estatisticamente significantes foram observadas somente entre o grupo A (1s) quando comparado aos grupos D (7s) e E (10s), e entre o grupo B (3s) quando comparado com o grupo E (10s). Quanto à rugosidade, verificou-se diferença estatisticamente significante apenas entre o grupo E (10s) quando comparado aos demais grupos. As cinco imagens obtidas pelo microscópio eletrônico de varredura (MEV) demonstraram bastante semelhança entre si, com padrão de condicionamento marcado por picos e vales, porém as imagens dos esmaltes jateados por 1 e 3 segundos apresentaram esses picos e vales em menor quantidade. Conclusão: a perda de estrutura dentária e a rugosidade da superfície do esmalte aumentaram conforme se aumentou o tempo de aplicação do jato de óxido de alumínio; a aplicação do jato de óxido de alumínio por 1 e 3 segundos promove menos perda de estrutura de esmalte do que quando se jateia o esmalte por 10 segundos; maior rugosidade pode ser obtida com o jateamento de óxido de alumínio por 10 segundos; entretanto, o aspecto morfológico do esmalte dentário é bastante similar, independentemente do tempo de jateamento. / Objective: To evaluate and compare the effects of aluminium oxide sandblasting on enamel surface when applied at different times. Materials & Methods: 110 premolars were obtained from the local tooth bank. The teeth were randomly divided into 5 groups (n = 22) for application of aluminium oxide sandblasting at different times. In Groups A, B, C, D and E, sandblasting with 50-?m aluminium oxide particles was applied for 01, 03, 05, 07 and 10 seconds, respectively. Quantitative assessments of enamel surface were performed by analysing changes in the profile and roughness (Sa) of the buccal surface before and after sandblasting application by using a profile gauge (Form Talysurf Intra, Taylor Hobson - AMETEK Inc, Pennsylvania, USA) and a laser interferometer (Talysurf CCl Lite, Taylor Hobson - AMETEK Inc, Pennsylvania, USA), respectively. A qualitative assessment of enamel surface was performed by means of scanning electron microscopy (SEM). For this latter analysis, a sample of each group was randomly chosen so that the sandblasted enamel surfaces could be adequately prepared to be evaluated. The quantitative data were compared by using ANOVA test, followed by post-hoc Tukey\'s test, at a significance level of 5% (P = 0.05). Results: Profile and roughness were found to be more altered as the sandblasting application time increased. With regard to the profile, however, statistically significant differences were found only in Group A (1s) compared to Groups D (7s) and E (10s), as well as in Group B (3s) compared to Group E (10s). With regard to the roughness, statistically significant difference was also observed only in Group E (10s) compared to the other groups. Five SEM images were demonstrated to be very similar to each other, with the conditioning pattern being marked by peaks and valleys, although SEM images of enamel blasted for 1 and 3 seconds showed peaks and valleys in lesser amount. Conclusion: Both loss of dental structure and enamel roughness increased as the time for application of aluminum oxide sandblasting also increased; application of aluminum oxide sandblasting for 1 and 3 seconds produced less loss of enamel structure compared to the 10-second application; more roughness can be obtained with application of aluminum oxide sandblasting for 10 seconds; however, the morphological aspect of the tooth enamel is very similar, regardless of the application time.
8

Efeito dos desafios erosivo ou erosivo/abrasivo sobre as estruturas dentárias adjacentes às restaurações realizadas com materiais contendo fluoreto ou cálcio / Effect of erosive and erosive/abrasive challenges on the dental hard tissues adjacent to restorations performed with materials containing fluoride or calcium

Viana, Ítallo Emídio Lira 29 January 2018 (has links)
Esse estudo avaliou in vitro o efeito dos desafios erosivo ou erosivo/abrasivo sobre materiais restauradores contendo fluoreto ou cálcio e sobre as estruturas dentárias adjacentes às restaurações realizadas com esses materiais. Fragmentos de esmalte e de dentina bovinos (4 mm × 4 mm × 2 mm), foram incluídos em resina acrílica e planificados. Uma cavidade padrão com dimensões 1,2 mm × 4 mm × 1,5 mm foi preparada nos espécimes, e restaurada de acordo com o material a ser testado: 1. Z350 - resina composta (Filtek Z350, 3M ESPE); 2. VB - compósito experimental contendo apenas vidros de bário; 3. DCPD30% - compósito experimental contendo 10% de vidros de bário e 30% partículas de fosfato di-cálcio di-hidratado (DCPD) funcionalizadas com dimetacrilato de dietilenoglicol (DEGDMA); 4. DCPD60% - compósito experimental contendo 60% partículas de DCPD funcionalizadas com DEGDMA; 5. Beautifil - GIOMER (Beautifil II, Shofu Dental Corporation); 6. Fuji IX - cimento de ionômero de vidro convencional de alta viscosidade (Fuji IX, GC Corporation); 7. Fuji II LC - cimento de ionômero de vidro modificado por resina (Fuji II LC, GC Corporation). Na sequência, os espécimes foram polidos e submetidos a dois tipos de tratamentos: erosão somente (n=10) ou erosão mais abrasão por escovação (n=10). A erosão foi realizada pela imersão dos espécimes em ácido cítrico a 0,3% (pH~2,6) por 5 min, seguido de 60 min de imersão em saliva artificial. Esse procedimento foi repetido 4×/dia, por 5 dias. A escovação foi realizada com uma suspensão de dentifrício padrão (Colgate Total 12 Mint Clean; 1450 ppm F-, como NaF) por 15 s (2 min de exposição total a suspensão de dentifrício), 2×/dia, 30 min após o primeiro e o quarto desafios erosivos. Ao final da ciclagem, a perda superficial (em ?m) do esmalte, da dentina e dos materiais restauradores foi determinada com um perfilômetro ótico. Para cada modelo (erosão e erosão-abrasão), os dados de perda superficial de esmalte, dentina e restauração foram analisados de maneira independente. Os dados foram analisados pelos testes de Kruskal-Wallis e Tukey. O nível de significância utilizado foi de 5%. No modelo de erosão, para esmalte, ambos cimentos ionoméricos apresentaram menor perda superficial do que o compósito Z350, apesar de Fuji II LC não ter se diferenciado significativamente dos grupos Beautifil e DCPD30%. Os outros grupos não foram diferentes de Z350 nem entre si. Para dentina, nenhum dos grupos foi diferente de Z350, com exceção de DCPD60%, o qual apresentou a maior perda superficial. Ambos cimentos ionoméricos apresentaram menor perda do que DCPD30%, Beautifil e DCPD60%. Em relação à restauração, os materiais Z350, Beautifil, VB, DCPD30% apresentaram perda superficial mínima, sem diferenças entre eles. Os cimentos ionoméricos apresentaram os maiores valores de perda, não se diferenciando de DCPD60%. No modelo erosão-abrasão, para esmalte, a menor perda superficial foi observada em Fuji II LC, sem diferença da Beautifil. Os outros grupos não se diferenciaram entre si nem da Beautifil. Para dentina, os grupos DCPD60%, Beautifil, Fuji II LC, Z350 e Fuji IX não se diferenciaram e, apresentaram menor perda superficial do que VB. Os cinco grupos citados também não foram diferentes de DCPD30%, com exceção de Fuji IX. Em relação à restauração, a maior perda foi observada para Fuji IX, sem diferenças de Fuji II LC e Beautifil. DCPD30%, Z350, VB e DCPD60% apresentaram valores mínimos de perda superficial, sem diferenças entre si. Concluiu-se que o cimento ionomérico Fuji II LC foi único capaz de proteger o esmalte adjacente à restauração contra desafios erosivos e erosivos/abrasivos, apesar de ter sido um dos materiais mais susceptíveis ao desgaste por ambos desafios. Para dentina, nenhum material exibiu efeito protetor. / This in vitro study evaluated the effect of erosive or erosive/abrasive challenges on restorative materials containing fluoride and calcium, and on the dental hard tissues adjacent to restorations performed with these materials. Enamel and dentin specimens (4 mm × 4 mm × 2 mm), obtained from bovine incisors, were embedded in acrylic resin, flattened and polished. In the specimens, a standard cavity of 1,2 mm × 4 mm × 1,5 mm was prepared and restored with the following materials: 1. Z350 - Composite resin without actives, Filtek Z350 (3MESPE); 2. VB - experimental composite containing barium glass only; 3. DCPD30% - experimental composite containing 10% of barium glass and 30% of DCPD particles functionalized with DEGDMA; 4. DCPD60% - experimental composite containing 60% of DCPD particles functionalized with DEGDMA; 5. Beautifil - GIOMER (Beautifil II, Shofu Dental Corporation); 6. Fuji IX - high viscosity glass ionomer (Fuji IX, GC Corporation); 7. Fuji II LC - resin-modified glass ionomer (Fuji II LC, GC Corporation). The specimens were polished again and then submitted to one of the two treatments: erosion only (n=10) or erosion plus toothbrushing abrasion (n=10). Erosion was performed by immersing the specimens in 0.3% citric acid solution (p~2.6), for 5 min, followed by 60 min exposure to artificial saliva. This procedure was repeated 4 times a day, for 5 days. Toothbrushing was performed with a slurry of a standard dentifrice (Colgate Total 12 Mint Clean; 1450 ppm F, as NaF), for 15 s (2 min total exposure time to the slurry), 2 times a day, 30 min after the first and last erosive challenges. At the end of cycling, enamel, dentin and restorative material surface loss (in ?m) were determined by optical profilometry. Data were analyzed by the Kruskal-Wallis and Tukey tests. The level of significance was 5%. In the erosion model, for enamel, both ionomeric cements presented lower surface loss than the Z350, although Fuji II LC did not differ significantly from Beautifil and DCPD30% groups. The other groups were no different from Z350 and from each other. For dentin, none of the groups were different from Z350, except for DCPD60%, which presented the highest surface loss. Both ionomeric cements presented lower loss than DCPD30%, Beautifil and DCPD60%. Regarding the restoration, the materials Z350, Beautifil, VB, DCPD30% showed minimal surface loss, with no differences between them. The ionomeric cements had the highest loss values, not differing from DCPD60%. In the erosion-abrasion model, for enamel, the lowest loss was observed for Fuji II LC, with no difference to Beautifil. The other groups showed no difference among them and from Beautifil. For dentin, the groups DCPD60%, Beautifil, Fuji II LC, Z350 and Fuji IX were no significant different and presented lower loss than VB. These five groups were also no different from DCPD30%, except Fuji IX. Regarding the restoration, the highest loss was observed for Fuji IX, with no difference from Fuji II LC and Beautifil. DCPD30%, Z350, VB and DCPD60% presented minimum values of surface loss, without differences between them. It was concluded that Fuji II LC ionomeric cement was the only material able to protect the enamel adjacent to the restoration against erosive and erosive/abrasive challenges, although it was one of the materials that was most susceptible to be wear off by both challenges. For dentin, no material exhibited a significant protective effect.
9

Comparação in vitro do desgaste dental em função da dureza de três diferentes tipos de materiais antagonistas / In vitro comparison of dental wear according to the hardness of three different antagonist materials

Ana Paula Cunha da Silva Costa 08 October 2010 (has links)
O objetivo deste estudo foi comparar in vitro o desgaste dental de pré-molares (PM) e molares (M) e sua relação com o valor de dureza Vickers dos materiais utilizados como antagonistas em uma máquina de abrasão simulada para provocar o desgaste nos dentes testados. Os materiais antagonistas utilizados foram VeraBond II (liga de Ni-Cr), Solidex (resina composta) e IPS Empress 2 (cerâmica). Para cada ensaio de dureza, foram preparados seis corpos-de-prova de cada material, os quais foram polidos sob refrigeração, com ciclo de 20 min para cada granulação. Num microdurômetro (HMV-2), foram realizadas três mossas por quadrante, cada uma sob carga de 19,614 N por 30 s, totalizando 12 mossas de base quadrada com ângulo de 136 entre os planos. O teste de abrasão foi realizado numa máquina simuladora de abrasão, freqüência de 265 ciclos/min e 4,4 Hz, com um percurso do antagonista de 10 mm à velocidade de 88 mm/s. Cada dente foi testado em oposição a um antagonista (foram 6 pares dente/material para cada grupo), em água deionizada, sob carga de 5 N, por 150 min, num total de 39.750 ciclos. Foram utilizados dezenove dentes 1 pré-molares, dezenove 3 molares e confeccionados doze antagonistas em cada material em forma de pastilha. Cada grupo de seis dentes foi testado em oposição a seis antagonistas do mesmo material. Ademais, um dente 1 pré-molar (PM) e um dente 3 molar (M) foram testados em oposição ao Plexiglass. Com relação ao desgaste do esmalte dentário (PM+M) segundo o material antagonista, o teste de Kruskal-Wallis evidenciou diferença significativa com p-valor < 0,001 e o teste de Mann-Whitney evidenciou diferença significativa nas comparações PM+M/resina X PM+M/metal (p-valor < 0,001), PM+M/resina X PM+M/cerâmica (p-valor < 0,001) e PM+M/metal X PM+M/cerâmica (p-valor = 0,002). A análise isolada, considerando pré-molares e molares separadamente, encontrou diferença significativa em relação ao desgaste do esmalte dentário no teste de Kruskall-Wallis, porém não detectou diferença significativa no teste de comparação múltipla Mann-Whitney quando comparou o desgaste sofrido pelo PM/metal em relação ao PM/cerâmica. Em relação à dureza Vickers detectou-se diferença significativa da dureza dos materiais no teste de Kruskall-Wallis (p-valor < 0,001) e também no teste de Mann-Whitney nas comparações múltiplas com p-valor = 0,002. Comparando-se a dureza com a perfilometria, observou-se uma correlação estatisticamente significativa (p &#8804; 0,05) na correlação negativa (&#961;= -0,829) entre a dureza do metal como material antagonista e o desgaste do esmalte dentário do dente molar. Os resultados sugeriram que todo material restaurador indireto estudado causou desgaste ao esmalte dentário quando submetido a forças de simulação de abrasão com carga. Embora tenha sido observada correlação entre dureza e resistência à abrasão, essa correlação foi pouco significativa. / The objective of this study was to compare the dental wear of pre-molars (PM) and molars (M) in vitro, and the relationship between dental wear and the Vickers hardness values of the materials used as antagonists in a machine simulating abrasion to produce wear on the teeth tested. The materials used as antagonists were VeraBond II (Ni-Cr alloy), Solidex (composite resin) and IPS Empress 2 (ceramic). Six specimens of each material were prepared for each hardness trial. The specimens were polished under refrigeration, with a 20-min cycle for each grit number. Three dents per quadrant were made in a microhardness tester (HMV-2), under a 19.614 N load for 30 s, for a total of 12 square-base dents with a 136 angle between planes. The abrasion test was performed in an abrasion-simulating machine set to a frequency of 265 cycles/min and 4,4 Hz. The course of the antagonist was 10 mm, at a speed of 88 mm/s. Each tooth was tested against an antagonist material (6 tooth/material pairs per group), in deionized water, under a 5 N load, for 150 min, for a total of 39,750 cycles. Nineteen first pre-molars (PM) and 19 third molars (M) were used, and 12 antagonistic discs were made in each material, for the tests. Each group of six teeth was tested against six antagonists of the same material. Additionally, 1 first pre-molar (PM) and one third molar (M) were tested against Plexiglass. Regarding the dental enamel wear on pre-molars and molars (PM+M) according to the antagonist material, the Kruskal-Wallis test revealed significant differences (p-value < 0.001) and the Mann-Whitney test also revealed significant differences for the following comparisons: PM+M/resin versus PM+M/metal (p-value < 0.001), PM+M/resin versus PM+M/ceramic (p-value < 0.001), and PM+M/metal versus PM+M/ceramic (p-value = 0.002). An analysis conducted with the Kruskall-Wallis test, considering pre-molars (PM) and molars (M) separately, found significant differences in relation to dental enamel wear (PM+M). However, when the multiple-comparison Mann-Whitney test was used, no significant difference was detected between the wear produced in the pre-molar/metal pair and that produced in the pre-molar/ceramic pair. Regarding Vickers hardness, both the Kruskall-Wallis test (p-value < 0.001) and Mann-Whitneys multiple-comparisons test (p-value = 0.002) revealed significant differences between materials. When hardness was compared with the profilometry data, a significant negative correlation was observed (p &#8804; 0.05, &#961; = -0.829) between the hardness of the metal as an antagonist material and the dental enamel wear of the molar tooth. The results suggested that all the indirect restorative materials tested caused wear of the dental enamel when submitted to the forces of simulated abrasion with load. Although a correlation was observed between hardness and resistance to abrasion, this correlation was hardly significant.
10

Análise quantitativa das partículas de óxido de alumínio geradas na abrasão a ar em consultório odontológico

Scannavino, Fábio Luiz Ferreira [UNESP] 18 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:27:48Z (GMT). No. of bitstreams: 0 Previous issue date: 2005-02-18Bitstream added on 2014-06-13T20:56:50Z : No. of bitstreams: 1 scannavino_flf_me_arafo.pdf: 459200 bytes, checksum: 7da03a73587b35e389935c5420bccdb6 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O sistema de abrasão a ar funciona por meio de energia cinética produzida por um jato pressurizado de partículas de óxido de alumínio, que tem a finalidade de abrasionar a superfície dentária. O objetivo deste estudo foi avaliar a efetividade do sistema de sucção, disponível em consultório odontológico, na captação das partículas de óxido de alumínio emitidas pelo aparelho de abrasão a ar. Um dispositivo metálico, que reproduzia as posições e as distâncias de trabalho do cirurgião-dentista, foi elaborado para a deposição das partículas de óxido de alumínio presentes no campo operatório durante a utilização do sistema de abrasão a ar. Para a aspiração do pó de óxido de alumínio foram empregadas as sucções de alta potência e odontológica convencional com sugadores convencional e modificado por funil. A quantificação das partículas foi obtida pela massa de óxido de alumínio depositada após a aplicação do aparelho de abrasão a ar. Os resultados obtidos pela estatística descritiva gráfica revelaram que a maior deposição das partículas ocorreu a 20 cm do centro da cavidade bucal e na posição de trabalho 9 horas, quando se utilizou o sugador convencional em alta potência de sucção. / The air abrasion system works using kinetic energy produced by pressurized air with aluminum oxide particles resulting in abrasion of the dental surface. The aim of this study was to compare the efficacy of high-volume evacuation (HVE) and conventional dental suction (CDS) in aluminum oxide particles evacuation. A metallic device was elaborated to reproduce the dentist operatory positions and to aluminum oxide particles deposition. The dust collection was made by conventional saliva ejector and modified ejector by funnel-shaped. The amount of particles showed that the greatest abrasive particles deposition occurred at the 20cm of distance from the center of the mouth at 9 o'clock operatory position with the conventional saliva ejector attached to high-volume evacuation (HVE).

Page generated in 0.0749 seconds