• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 116
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • Tagged with
  • 120
  • 70
  • 23
  • 18
  • 17
  • 17
  • 16
  • 14
  • 14
  • 14
  • 14
  • 14
  • 13
  • 12
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Produção de espécies ativas de N2+ e CN numa pós-descarga de N2-CH4 em regime de pink afterglow :

Levaton, Jacques January 2000 (has links)
Dissertação (Mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. / Made available in DSpace on 2012-10-18T02:02:35Z (GMT). No. of bitstreams: 0Bitstream added on 2014-09-25T19:13:39Z : No. of bitstreams: 1 161521.pdf: 48732743 bytes, checksum: 5ba6bc8e27f523d283b5c55a82efcce2 (MD5) / Neste trabalho foram determinadas as condições experimentais necessárias para a geração do regime de pós-descarga denominado de "pink afterglow" numa descarga D.C. de N2 em fluxo. Fortes emissões oriundas dos 1o sistema negativo e 1o e 2o sistemas positivos do nitrogênio foram detectadas na região de pós-descarga até distâncias superiores a 15 cm a partir do final da descarga. Um modelo cinético para a formação das espécies radiativas responsáveis pelas emissões foi proposto para o regime de "pink afterglow". Constatou-se que, fundamentalmente são os processos vibracionais os precursores da excitação dos estados eletrônicos (B3Pg, v), (C3Pu, v) e da ionização na "pink", a qual apresenta dois mecanismos de geração distintos pela temperatura vibracional e tempo de residência das espécies. No intuito se estudar a possibilidade da tratamentos de nitretação e carbonitretação de aço no regime de "pink afterglow", introduziu-se CH4 na região de pós-descarga. Constatou-se que traços deste gás são suficientes para inibir os principais mecanismos da "pink" destruindo sua emissão. Neste caso, evidencia-se uma significativa produção de radicais CN pela forte emissão do sistema violeta do CN. Resultados preliminares sobre tratamentos de nitretação e carbonitretação em pós-descargas de N2-CH4 em regime de "pink afterglow"são apresentados.
2

Avaliação do ponto efetivo de medida em câmaras de ionização cilíndricas usadas em feixes de elétrons com energias entre 6 e 20 MeV

Araujo, Margareth Maria de 27 July 1984 (has links)
Orientador: Carlos Eduardo de Almeida / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-14T03:13:59Z (GMT). No. of bitstreams: 1 Araujo_MargarethMariade_M.pdf: 1675415 bytes, checksum: de094a1ab66cb55bcc8f1bb1ea4c6922 (MD5) Previous issue date: 1984 / Resumo: Quando câmaras de ionização são usadas em feixes de elétrons de alta energia uma perturbação no fluxo de elétrons é introduzida no meio. Tem-se observado em muitos experimentos que a resposta da câmara correlaciona o fluxo de elétrons no ponto efetivo, de medida deslocado do centro geométrico da cavidade da câmara. Tal deslocamento é definido como sendo o deslocamento radial. O deslocamento radial foi determinado em um simulador de água com um feixe de elétrons com energias entre 6 e 20 MeV, utilizando-se três câmaras de ionização cilíndricas comerciais com diâmetros internos variando entre 3,5 e 9,0 mm. As câmaras foram irradiadas com seu eixo principal perpendicular à direção de incidência do feixe. Uma tensão coletora de 300 V foi aplicada às câmaras. As medidas foram efetuadas em ambas as polaridades, tomando-se a média das leituras. Verificou-se que, com o aumento da profundidade no simulador, o deslocamento radial permanece constante para o feixe de 8,9 MeV, aumenta para o de 12,6 MeV e diminui para os feixes de 16,8 e 19,7 MeV. Construiu--se um modelo teórico para calcular o deslocamento do ponto efetivo de medida, baseado na teoria de "espalhamento múltiplo de Fermi-Eyges e no formalismo desenvolvido por Jette (1983), para um feixe retangular de elétrons terapêuticos. Encontrou-se que o deslocamento radial permanece constante com o aumento da profundidade, diminui com o aumento da energia média do feixe incidente e é dependente com o raio da câmara. Os resultados experimentais e teóricos são comparados, encontrando-se boa concordância para os elétrons de 8,9 e 12,6 MeV, enquanto que para elétrons de 16,8 e 19,7 MeV modificações no modelo se fazem necessárias / Abstract: When ionization chambers are used. in high energy electrons beams, a disturbance of the electron flux in medium is introduced. As observed in many experiments the response should be correlated to the electron flux at the effective point of measurement which is generally displaced from the geometrical center of the chamber. The radial displacement was determined in a water phantom for electrons beams at energies from 6 to 20 MeV for three commercial cylindrical ionization chambers of internal diameters varying from 3.5 to 9.0 mm. The chambers were irradiated with the main axis perpendicular to the direction of the beam. A 300 V bias voltage was applied and readings were taken with both polarities. It was observed that, with increasing depth in the water phantom, the radial displacement remains constant for the 8.9 MeV beam, it increases for the 12.6 MeV electrons and decreases for those of 16.8 and 19.7 MeV. A theoretical model was built in. order to calculate the displacement of the effective point of measurement. The Fermi-Eyges multiple scattering theory and a rectangular beam formalism developed by Jette (1983) for therapeutic electron beam are used. It was found that the radial displacement stays constant with increasing depth and it decreases with increasing average energy of the incident beam. The model also predicts that the displacement is dependent on the chamber radius. The experimental and theoretical results are compared. They show good agreement for 8.9 and 12.6 MeV electron, while for 16.8 and 19.7 MeV electrons they indicate that modifications in the theoretical model are necessary / Mestrado / Física / Mestre em Física
3

Desenvolvimento de uma câmara de ionização para o LNLS

Tamura, Edilson 12 January 1996 (has links)
Orientador: Helio Cesar Nogueira Tolentino / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-21T19:01:35Z (GMT). No. of bitstreams: 1 Tamura_Edilson_M.pdf: 2735994 bytes, checksum: 95c92842a04b2d0625a10ce9d5d59aa7 (MD5) Previous issue date: 1996 / Resumo: Apresentamos uma câmara de ionização para monitorar e medir a intensidade do feixe de raios-x. Este detector será utilizado em estações experimentais da fonte de radiação síncrotron, que está sendo construída pelo Laboratório Nacional de Luz Síncrotron -LNLS. A câmara de ionização tem a configuração de placas paralelas e pode trabalhar com diferentes tipos de gases e pressões. A calibração da câmara, ou seja, a relação entre a corrente gerada pela câmara e a intensidade dos fótons incidentes, foi obtida utilizando o ar a 1 atm para fótons com energias de 5,4 keV, 8,4 keV e 17,5 keV. A calibração mostrou uma baixa eficiência da câmara, principalmente para fótons com energias altas, motivando um estudo com outros tipos de gases (N2, He, Ar e mistura P-10) a diferentes pressões. Foi desenvolvida e caracterizada a eletrônica para leitura da câmara de ionização. O ruído e a instabilidade desta eletrônica mostraram desempenhos comparáveis a um eletrômetro comercial / Abstract: We describe an ionization chamber for monitoring and measuring the x-ray beam intensity .This detector will be used in the workstations of the synchrotron radiation facility , which is being constructed at Laboratório Nacional de Luz Síncrotron -LNLS. The ionization chamber has the two parallel plates configuration, and works with different types of gas and pressures. The ionization chamber calibration, i.e., the relation between the ionization chamber current and photon intensity into the chamber, was obtained using the air at 1 atm for 5.4 keV, 8.4 keV and 17.5 keV photon energies. The calibration showed a low efficiency of the chamber, mainly for high energy photon. This result motivated to study the efficiencies for different gases (N2, He, Ar and P-10) at different pressures. We developed and characterized the electronic for the ionization chamber readout. The noise and the instabilities of this electronic is comparable with a commercial electrometer / Mestrado / Física / Mestre em Física
4

Investigação de energias de ionização e intensidades vibracionais (IV) utilizando o modelo potencial simples

Haiduke, Roberto Luiz Andrade 03 August 2018 (has links)
Orientador: Roy Edward Bruns / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-08-03T12:09:22Z (GMT). No. of bitstreams: 1 Haiduke_RobertoLuizAndrade_D.pdf: 2680501 bytes, checksum: f3c3720268089811f1de7744220a9d0f (MD5) Previous issue date: 2003 / Doutorado
5

O modelo do potencial simples como criterio para avaliação da qualidade de cargas atomicas

Haiduke, Roberto Luiz Andrade 25 July 2018 (has links)
Orientador: Roy Edward Bruns / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-25T09:02:51Z (GMT). No. of bitstreams: 1 Haiduke_RobertoLuizAndrade_M.pdf: 747791 bytes, checksum: ba415ff1887b30292171557a927d6287 (MD5) Previous issue date: 1999 / Mestrado
6

Anteprojeto de um implantador de ions para 40 KeV

Damiani, Furio, 1943-2016 14 July 2018 (has links)
Orientador : C.I.Z. Mammana / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Campinas / Made available in DSpace on 2018-07-14T09:14:46Z (GMT). No. of bitstreams: 1 Damiani_Furio_M.pdf: 3573443 bytes, checksum: 4aaecc119d7be2531b5e73247c5f092e (MD5) Previous issue date: 1976 / Resumo: Este trabalho documenta a experiência obtida no projeto e construção de um implantador de íons no LME-EPUSP e o subsequente projeto de um implantador de íons para o Laboratório de Eletrônica e Dispositivos da Faculdade de Engenharia da UNICAMP. Foram concluÍdos os projetos e desenhos de execução das partes componentes do implantador do LED tendo sido introduzidas diversas modificações baseadas na experiência anteriormente citada e também nas características propostas para o implantador do LED. Entre estas podemos citar a elaboração de uma fonte de íons de concepção mais simples a utilização de um espectrômetro massa tipo setor magnético, uma câmara de alvo aperfeiçoada. O sistema de vácuo é totalmente automático / Abstract: Not informed / Mestrado
7

Desenvolvimento e caracterização de uma câmara de ionização totalmente polimérica para dosimetria de Raios-X

AMAZONAS, Irani Buarque do January 2005 (has links)
Made available in DSpace on 2014-06-12T23:16:50Z (GMT). No. of bitstreams: 2 arquivo9068_1.pdf: 798927 bytes, checksum: 75fbf36a5ed3683fdde14a8b96763663 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2005 / Este trabalho apresenta o desenvolvimento e a caracterização de um protótipo de uma câmara de ionização de placas paralelas (CIPP), totalmente polimérica, construída com eletrodos de PANI condutora depositada sobre um substrato de poli (metacrilato de metila), PMMA, que além de servir como suporte ao filme de PANI, também serve para prover o equilíbrio eletrônico dos elétrons gerados pela radiação. A caracterização do detetor proposto, a câmara de ionização WELI, foi feita a partir das curvas características de uma câmara de ionização, tais como: curva de saturação, dependência energética e resposta com relação à taxa de dose. Também foram avaliadas as mudanças nas características elétricas dos eletrodos de PANI, em função da dose acumulada, a geometria do detetor, a dependência angular da resposta, sua estabilidade a curto prazo, além da variação da resposta com a separação dos eletrodos. O protótipo testado foi comparado com a câmara PTW2532 para raios-X na região de 20kV até 140kV, mostrando um desvio padrão menor que 1% entre as respostas, entre 70kV e 90kV. Até o momento ainda não se tem conhecimento de uma tecnologia nacional para um sistema de detecção similar ao protótipo desenvolvido neste projeto de pesquisa. A importância desse trabalho reside basicamente em três aspectos: a) o polímero condutor, PANI, é um material ainda em um estado incipiente de sua utilização na área dosimétrica, despertando muito interesse tecnológico; b) devido à ausência de partes metálicas, uma câmara de ionização totalmente polimérica permite diminuir a radiação espalhada, importante fator de interferência na leitura; c) o polímero suporte, PMMA, sugere que o protótipo seja bastante robusto, resistindo ao manuseio e a pequenos impactos sem maiores danos
8

Calculos de potenciais de ionização de algumas bases e aza-analogas utilizando o metodo semi-empirico HAM/3

Cirino, Jose Jair Vianna 19 July 2018 (has links)
Orientador: Yuji Takahata / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-19T13:42:41Z (GMT). No. of bitstreams: 1 Cirino_JoseJairVianna_M.pdf: 4385163 bytes, checksum: 54883fff59d9899a652944c0dc2de2ab (MD5) Previous issue date: 1994 / Mestrado
9

Estudo termodinamico da interação de tensoativos ionicos com tripsina

Silva Filho, Eloi Alves da 20 July 2018 (has links)
Orientador: Pedro L. O. Volpe / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Quimica / Made available in DSpace on 2018-07-20T05:05:54Z (GMT). No. of bitstreams: 1 SilvaFilho_EloiAlvesda_D.pdf: 2324435 bytes, checksum: cff02643fe1c231fb562af4fe6d9df31 (MD5) Previous issue date: 1995 / Doutorado
10

Caracterização das qualidades de radiação X seguindo as recomendações da norma IEC 61267 no laboratório de calibração do IPEN / X RADIATION QUALITIES CHARACTERIZATION FOLLOWING THE STANDARD IEC 61267 RECOMMENDATIONS AT THE CALIBRATION LABORATORY OF IPEN

Franciscatto, Priscila Cerutti 16 September 2009 (has links)
Este trabalho apresenta uma metodologia para a caracterização das qualidades de radiação X, seguindo as novas recomendações do International Electrotechical Commission (IEC) com a norma 61267, para a implantação de um novo procedimento de calibração de sistemas dosimétricos utilizados na área de radiodiagnóstico. As qualidades de radiação de referência: RQR 2 a RQR 10, RQA 2 a RQA 10, RQB 2 a RQB 10 e RQN 2 a RQN 10 foram implantadas no laboratório de calibração do IPEN (LCI). Suas características foram analisadas por meio de medidas dos parâmetros destes feixes como: a tensão de pico prático (PPV), filtrações adicionais específicas para cada qualidade de radiação, 1ª e 2ª camadas semi-redutoras e coeficiente de homogeneidade. Para os filtros adicionais, foi utilizado alumínio de alta pureza em torno de 99,9%. A filtração inerente do tubo de raios X também foi determinada. Com a implantação destas qualidades de radiação, o LCI estará pronto para calibrar os instrumentos medidores de radiação nas novas qualidades recomendadas, permitindo assim, uma melhoria na qualidade dos serviços radiológicos que o IPEN oferece para todo o País. / This work presents a methodology for the X radiation qualities characterization following the new recommendations of the standard 61267 of the International Electrotechnical Commission (IEC) to establish a new procedure for calibration of dosimetric systems used in the field of diagnostic radiology. The reference qualities radiation of IEC 61267: RQR 2 to RQR 10, RQA 2 to RQA 10, RQB 2 to RQB 10 and RQN 2 to RQN 10 were implanted at the calibration laboratory of IPEN (LCI). Their characteristics were analyzed through measurements of beam parameters such as: Practical peak voltage (PPV), specific additional filtrations for each qualities (high purity aluminum of about 99.9%), 1st and 2nd Half Value Layers, homogeneity coefficient. The inherent filtration of the X ray tube was also determined. With the establishment of these radiation qualities, the LCI will be ready to calibrate the measuring instruments of radiation in the new qualities, allowing an improvement in radiological services offered by IPEN.

Page generated in 0.0584 seconds