• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 101
  • Tagged with
  • 101
  • 101
  • 81
  • 29
  • 28
  • 26
  • 25
  • 17
  • 17
  • 16
  • 15
  • 14
  • 13
  • 13
  • 12
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação técnica de tubos emissores para irrigação localizada /

Baca Garcia, Carlos Jesus, 1971- January 2006 (has links)
Orientador: Raimundo Leite Cruz / Banca: Antônio de Pádua Sousa / Banca: Edmar José Scaloppi / Banca: Alexandre Barcelos Dalri / Banca: Jarbas Honório de Miranda / Resumo: Com o desenvolvimento da tecnologia dos plásticos, tornou-se possível à construção de tubos emissores, com padrão de qualidade, a custos relativamente baixos. O emprego da irrigação localizada, pelo sistema de gotejamento, ganhou no Brasil novo impulso a partir dos anos 90, com a instalação de diversas empresas internacionais especializadas neste mercado. As empresas mais importantes do mundo se fazem presente no Brasil e algumas multinacionais estão produzindo aqui parte de sua linha de produção, como: Netafim, Plastro, Amanco, NaanDan e como empresa brasileira fabricante, existe a Petroisa. Esse trabalho teve por objetivo caracterizar e avaliar de forma técnica e hidráulica alguns tubos emissores para gotejamento, comercializados no mercado brasileiro de acordo com as normas ISO 8796:2004 e ISO 9261:2004. O experimento foi conduzido no Laboratório de Irrigação do Departamento de Engenharia Rural, da Faculdade de Ciências Agronômicas, Universidade Estadual Paulista "Julio de Mesquita Filho" - Campus de Botucatu, São Paulo. A norma ISO 9261:2004 prescreve critérios para avaliar e especificar gotejadores com vazão inferior a 24 L h-1 e tem por característica principal, a flexibilidade para adaptar economicamente qualquer laboratório de irrigação, porque não especifica as características da bancada de ensaios. 2 Os ensaios visaram à determinação dos seguintes parâmetros: Coeficiente de variação de fabricação, equação característica da relação entre pressão e vazão, espessura da parede, diâmetro interno, espaçamento entre emissores, resistência à pressão hidráulica à temperatura ambiente e à temperatura de 40oC, resistência à tensão de 160 N e 180 N, e ensaio de envelhecimento precoce. As análises mostraram um coeficiente de variação de fabricação (CVf) inferior a 0,07 para todos os tubos emissores... (Resumo completo, clicar acesso eletrônico abaixo). / Abstract: With the domain of the technology of plastics, it became possible to manufacture quality emitting pipes standard, at relatively low costs. Trickle irrigation method, using emitting pipes, gained in impulse Brazil during last decade 90, with the installation of several specialized international industries. Multinationals industries such as Netafim, Plastro, Amanco, NaanDan and a Brazilian manufacturer, Petroisa are producing here part of its line of production. This work had the objective, to characterize and evaluate emitting pipes, commercialized in Brazil according to ISO 8796 and ISO 9261:2004 standards. The 4 tests were conducted in the Laboratory of Irrigation of the Faculdade de Ciências Agronômicas - Campus of Botucatu, São Paulo, Brazil. The following parameters were evaluated: manufacturing variation, pressure and discharge equation, thickness of the wall, internal diameter, emitters spacing, resistance to the hydraulic pressure at the current temperature and at raised temperature (40oC), resistance to the 160 tension and 180 N, and precocious aging. The analyses had shown manufacturing coefficients of variation below 0,07 for all the emitting pipes, (maximum value allowed by ISO 9261:2004) standard. The exponents of pressure (x), in the pressure discharge e friction were of 0.431, 0.502, 0.450, 0.575, 0.533, 0.480, 0.470 for Petro Drip, Golden Drip, Chapin, Queen Gil, Aqua Traxx, Tiran and Amanco Drip, emitters respectively, classifying them as not compensating. For ISO 9261:2004, the value of x should not exceed 0.2 to be classified as compensating. The evaluated emitters (Ram, Naan PC, Amanco Drip PC and Twin Plus) had values lesser than 0,075. The test of resistance to the tension, as ISO 9261:2004 is a useful tool to classify an emitting in reusable and not reusable pipe. Aqua Traxx emitter was classified as not reusable. It presented probably... (Complete abstract, click electronic address below). / Doutor
32

Balanço de energia e evapotranspiração de cafezal adensado em crescimento sob irrigação localizada. / Energy balance and evapotranspiration in a high density young coffee under located irrigation.

Evandro Zanini Righi 28 January 2005 (has links)
Foram determinadas as taxas de evapotranspiração global (ETc) e sua partição em evapotranspiração dos renques e das entrelinhas, bem como a partição da energia disponível em calores sensível e latente de um cafezal adensado (3,50m x 0,90m), irrigado por gotejamento, durante o período de 1 a 2 anos após sua implantação, em Piracicaba, SP. Foram utilizados os métodos do balanço de energia–razão de Bowen (MRB) e aerodinâmico (MA) para a determinação de ETc, o método lisimétrico para a evapotranspiração dos renques e o método do balanço de calor no caule para a transpiração a partir do fluxo de seiva. No uso do MA, foram verificados vários problemas. Um deles, é o aumento inicial pequeno do “deslocamento do plano zero” (d) normalizado pela altura da cultura, ter sido seguido por um decréscimo teoricamente inconsistente com o aumento da altura dos cafeeiros, além de uma grande variação do comprimento de rugosidade (zo), dependente das condições de cobertura das entrelinhas, da direção e da velocidade do vento, sendo evidenciado efeito dessas últimas duas variáveis também sobre d. Provavelmente, a maior fonte de erro para o MA foi terem os coeficientes de transporte turbulento, determinados com as funções empíricas do número de Richardson de estabilidade atmosférica, válidas para a subcamada atmosférica inercial e superfícies homogêneas, mostrado-se inadequados para as condições do estudo, resultando em valores irreais de ETc. As estimativas pelo MRB foram satisfatórias, por ter ocorrido boa similaridade entre os perfis de temperatura e de pressão de vapor do ar, indicando que a razão entre os coeficientes de difusão turbulenta para calor sensível e latente se manteve próxima de 1. Durante o período seco, grande parte dos dias tiveram as determinações de ETc pelo MRB comprometidas, devido aos pequenos gradientes de pressão de vapor e aos erros causados pelos sensores dos psicrômetros. O fluxo de calor latente do cafezal correspondeu a mais de 80% da energia disponível no período úmido, diminuindo para valores da ordem de 64% no período seco. Os valores do coeficiente “global” de cultura (razão entre ETc e a evapotranspiração de referência (ETo)), variaram entre 1,04 e 1,30, sendo altamente dependentes das condições de umidade do solo. No último período de medida, o valor de aproximadamente 0,86 deve ser tomado com ressalvas devido a problemas de manejo da área. O “coeficiente de evapotranspiração do renque”, sendo a razão entre a evapotranspiração do renque (evaporação do solo da área contínua sob as copas mais a transpiração dos cafeeiros) e ETo, variou entre 0,22 e 0,43, sendo influenciado pelas condições de umidade da superfície, especialmente pela área molhada na irrigação, e pelo aumento da área foliar dos cafeeiros. Os valores do coeficiente basal de cultura (razão entre transpiração dos cafeeiros e ETo) variaram de 0,03 a 0,20. Durante o período seco evidenciou-se efeito advectivo sobre as medidas, adotando-se critérios para selecionar dias com tal efeito nulo, ou mínimo, sobre os valores médios dos coeficientes acima. / The objectives of this study were to evaluate the magnitude of global evapotranspiration (ETc) in a high density young coffee crop (3.5mx0.9m) under drip irrigation, the ETc partition considering hedgerows and interrows, and the partition of the available radiant energy between sensible and latent heat fluxes. The experiments were conducted from September 2002 to September 2003, in Piracicaba, SP, Brazil. ETc was determined by the Energy balance–Bowen ratio (BRM) and aerodynamic (AM) methods. Hedgerows evapotranspiration was measured by weighing lysimeters and coffee transpiration by the sap flow using the stem heat balance method. When AM was used, several problems were observed. One of them was the “zero plane displacement” (d) normalized by the crop height, which showed an earlier small increase, followed by an unexplained decrease when plant height increased, besides of a huge variation of the roughness length (zo), which depended on interrows cover conditions and wind direction and speed. Also, the effect of these former was noticed on d. Probably, the major source of error in AM was the use of turbulent transport coefficients determined with empirical functions, using the Richardson number, valid for homogeneous surfaces, and measurements taken on the inertial atmospheric sublayer. This procedure proved to be inadequate for the heterogeneous coffee crop surface, resulting in unrealistic ETc values. The BRM estimates of ETc were more appropriate, as a consequence of the good similarity between potential temperature and vapor pressure profiles, indicating that the ratio between the turbulent transport coefficients for sensible and latent heat was close to unity. During the dry season, in the majority of the days with measurements, ETc estimates were less effective due the small vapor pressure gradients and the errors caused by the psychrometer sensors. The ratio between global latent heat flux and available surface energy was higher than 80% in the wet season, decreasing to 64% when the interrows were drying. The “global” crop coefficient (Kc), representing the ratio between ETc and reference evapotranspiration (ETo) ranged from 1.04 to 1.30, being highly dependent on soil moisture conditions. In the latest period of measurements, Kc was about 0.86, which must be analyzed with care due problems in the coffee crop management. The “hedgerows evapotranspiration coefficient”, which means the ratio between hedgerows evapotranspiration (evaporation of continuous soil area under hedgerows plus the crop transpiration) and ETo, ranged from 0.22 to 0.43, being influenced by soil moisture, especially by the soil surface area wetted by the drip irrigation and by the increase of leaf area. The basal crop coefficient (ratio between transpiration and ETo) ranged from 0.03 to 0.20. During the dry season, effect of advection on the measurements was observed; so, some criteria were used to select days in which this effect was considered to be null or having a minimum degree, in order to calculate the mean values of the above described coefficients.
33

Proposta de norma técnica de ensaio para tubogotejadores de irrigação: resistência ao entupimento por particulados sólidos em suspensão / Proposed Technical Standard Testing dripline (Irrigation): Resistance to clogging by particulates in Suspension

Faria, Lucas do Amaral 12 December 2012 (has links)
No mercado nacional de irrigação localizada, a indústria de gotejamento disponibiliza uma ampla gama de emissores, cujas tecnologias são provenientes de diferentes países: Israel, Espanha, EUA, Grécia, Índia, etc. Aos projetistas, técnicos e agricultores irrigantes que atuam no Brasil, cabem à árdua tarefa de selecionar os tipos de emissores mais adequados na implantação dos projetos. Este trabalho teve por objetivo apresentar uma proposta de Norma Técnica para ensaios de tubogotejadores, em função da presença de partículas sólidas em suspensão na água de irrigação. Avaliar o desempenho dos tubos emissores é algo bastante desejado, pois torna a escolha dos emissores mais técnica e segura. Propostas de normas técnicas devem focar a princípio em ensaios de grande porte com a análise de vários emissores simultaneamente, durante a fase inicial de criação do banco de dados. Estudou-se neste trabalho o posicionamento dos emissores tipo pastilha, com os orifícios direcionados para cima e para baixo durante os ensaios, assim como a distribuição do fluxo de água por meio do mainfold de alimentação dos tubogotejadores na bancada e sua influência no caminhamento seletivo de partículas sólidas nos ensaios de grande porte. O experimento foi conduzido em três fases distintas, utilizando-se duas faixas granulométricas de dióxido de silício (SiO2) na água bombeada (areia muito fina e areia média), com as seguintes características: a) partículas com diâmetros de 0,053 a 0,103 mm nas primeiras 80 horas; b) Partículas com diâmetros de 0,103 a 0,250 mm entre 80 a 160 horas e c) Partículas com diâmetros de 0,250 a 0,500 mm entre 160 a 240 horas de ensaio. As fases foram baseadas em duas concentrações de partículas em suspensão, com 125 ppm e 500 ppm para um tempo total de ensaio de 480 horas. Para testar a hipótese de que um mesmo tubogotejador poderia apresentar comportamento diferenciado de resistência ao entupimento em função da posição de entrada do tubogotejador no mainfold, utilizou-se um delineamento em blocos não casualisados e para a comparação das médias de vazões relativas o teste Scott Knott com significância de 5% na análise de variância. Constataram-se diferenças significativas de vazões relativas nos tratamentos de posição dos emissores pastilhas, de tipos de emissores, e posições no mainfold confirmando as hipóteses iniciais do trabalho. Em função dos resultados obtidos sugere-se uma proposta de norma técnica para este tipo de ensaio de resistência ao entupimento de tubogotejadores. / In the market for drip irrigation, drip provides a wide range of issuers, whose technologies are coming from different countries: Israel, Spain, USA, Greece, India, etc.. To designers, technicians and farmers irrigators operating in Brazil, fit the arduous task of selecting the appropriate type of transmitter in deployment projects. The study aimed to propose a Technical Standard for testing large, due to the presence of suspended solids in the irrigation water conducted from August 2010 to June 2012. Evaluate performance of the tubes emitters is quite desired, as it makes the choice of emitters safer and should focus on the large test - analyzing large amounts of both issuers / initial phase of creating the database. We studied also the positioning of the emitters type wafer with holes directed upwards and downwards. The main detail analysis was performed for the distribution of water flow through \"mainfold\" Feed the dripline on the bench and their influence on selective traversal of solid particles in the test large. The experiment was conducted in three distinct stages, using two particle sizes of silicon dioxide (SiO2) in water pumped from very fine sand and medium sand, described below: a) particles with diameters of 0.053 to 0.103 mm in the first 80 hours, b) particles with diameters from .103 to .250 mm 80 to 160 hours and c) Particle diameter 0.250 to 0.500 mm between 160 to 240 hours of testing. The phases are performed in two concentrations of particles in suspension with 125 ppm, and then with 500 ppm of the total time test at 480 hours. To test the hypothesis that the same behavior tubogotejador could present different resistance to clogging as a function of input position with the tubogotejador \"mainfold\", used a non-randomized block design, and the Scott test, with significance of Knott 5% in the analysis of variance to compare the means. Differences were found in the treatments of the emitters position lozenges, flow variations between types of emitters, between blocks (positions of the mainfold) and particle sizes and concentrations of silicon dioxide, confirming the hypothesis initial work. Depending on the results obtained, some models have produced significant effects, and also the different installation positions pad (up, down) and suggest a proposed technical standard for this type of test for resistance to clogging of emitters.
34

Dimensionamento e simulação hidráulica da irrigação localizada sob condição variável de setores de operação. / Trickle irrigation design and hidraulic simulation under variable operation condition.

Carvalho, Guilherme Busi de 17 December 2004 (has links)
Este trabalho teve como objetivo, desenvolver um programa computacional em linguagem Visual Basic Application® para dimensionamento da malha hidráulica de sistemas de irrigação localizada e simulação da operação em diferentes combinações de parcelas com funcionamento simultâneo (setores de operação), visando analisar o comportamento dos parâmetros dimensionais da malha hidráulica: vazão, velocidade da água, pressão real e nominal ao longo da tubulação, pressão de entrada no cavalete das parcelas e rendimento do conjunto moto-bomba. O modelo foi aplicado a um projeto hipotético de irrigação localizada por microaspersão com emissores autocompensantes na cultura de citros. As equações utilizadas para os cálculos da perda de carga foram Hazen-Williams e Darcy-Weisbach, podendo o usuário do aplicativo escolher entre as duas fórmulas para realizar as simulações desejadas. O aplicativo mostrou-se eficiente nos cálculos hidráulicos, permitindo ao usuário, por meio das simulações, escolher qual a combinação de parcelas de funcionamento associadas às características do conjunto moto-bomba e às necessidades do produtor em utilizar o sistema que melhor se ajusta ao projeto de irrigação. / This work aims to present, a computational tool, developed in Visual Basic Application® language, applied to trickle irrigation network design and to simulate different block combinations operation (set of parcels operated at the same time), in order to analyze the network parameters behavior: flow, water speed, real and nominal pressure along the pipeline, parcel input pressure and pump parameters. The model was applied to a trickle irrigation hypothetical citrus project. The equations proposed to calculate head loss are Hazen-Williams and Darcy-Weisbach; users can choose between them to accomplish the hydraulics simulations desired. The application was shown efficient in the hydraulic calculations, allowing to the user, through the simulations, to choose which combination of parcels operation that better adjusted to the irrigation project and water management.
35

Desempenho de unidades gotejadoras operando com diluições de efluentes de laticínios e de água de abastecimento público em escala laboratorial

Marques, Blake Charles Diniz 29 February 2016 (has links)
Submitted by Lara Oliveira (lara@ufersa.edu.br) on 2016-11-17T20:43:02Z No. of bitstreams: 1 BlakeCDM_TESE.pdf: 4892316 bytes, checksum: 86d0db1f3948e83dab7334504ce8a41f (MD5) / Approved for entry into archive by Vanessa Christiane (referencia@ufersa.edu.br) on 2017-01-24T14:46:43Z (GMT) No. of bitstreams: 1 BlakeCDM_TESE.pdf: 4892316 bytes, checksum: 86d0db1f3948e83dab7334504ce8a41f (MD5) / Approved for entry into archive by Socorro Pontes (socorrop@ufersa.edu.br) on 2017-01-31T13:40:34Z (GMT) No. of bitstreams: 1 BlakeCDM_TESE.pdf: 4892316 bytes, checksum: 86d0db1f3948e83dab7334504ce8a41f (MD5) / Made available in DSpace on 2017-03-21T14:51:08Z (GMT). No. of bitstreams: 1 BlakeCDM_TESE.pdf: 4892316 bytes, checksum: 86d0db1f3948e83dab7334504ce8a41f (MD5) Previous issue date: 2016-02-29 / The problem of water crisis is directly related to factors such as increasing population, increased demand for water, climate variations and deterioration of existing resources. In the semi-arid Northeast the predominant characteristics of reduced rainfall, high temperature and high evaporative rate, make the shortage of water for long periods of the year, more and more recurrent. Liquid effluents of dairy industries have the potential for agricultural use due to nutrient intake. However, this practice involves technical feasibility issues inherent in the method of irrigation adopted where the clogging of the emitters becomes more vulnerable, but can be attenuated with the technique of dilution in water. Given the above, the study aimed to analyze the hydraulic performance drippers units applying wastewater dilution dairy (ARL) and the public water supply (AA). For this, it was set up a trial bench, the Pollution Laboratory and Land Degradation (LPDS) of the Federal Rural University of Semi-Arid (UFERSA) campus Mossoro-RN, consisting of four drippers units operating with four different dilutions of ARL in AA (1A0E; 1A1E; 2A1E and 3A1E) and five types of drippers (G1, G2, G3, G4 and G5). The hydraulic performance of drippers units was obtained every 40 hours of operation with dilutions of ARL AA for 200 h at 2014 20/10 10/04 2015 period, using the indicators drip flow ( Q) flow variation coefficient (CVQ), statistical uniformity coefficient (US), distribution uniformity coefficient (CUD) and reduction of the relative flow rate (Dr). At the same time, they quantified the physicochemical and microbiological attributes of ARL dilutions AA. Data were submitted to analysis of simple and multiple regression and parametric test of Pearson correlations. Among the physicochemical and microbiological characteristics of dairy effluent, solid values suspended (SS), dissolved solids (DS), pH and total iron (Fe) represented drippers clogging risk ranging from moderate to high. The SS features, SD, pH and Fe predominated in multiple linear regression equations adjusted to the hydraulic performance variables, combinations between types of drippers and dairy effluent dilution levels in the public water supply. At the end of the experimental tests, samples of emitters biofouling were subjected to photographic records and analyzes by optical microscopy and scanning electron microscopy (SEM), showing the formation of a biofilm on the entire internal area of the sampled emitters resulting in partial clogging and total tested drippers, thus affecting the hydraulic system performance. Hydraulic performance indicators Q, CUD, CVQ and Us satisfactorily expressed the drippers obstruction levels, while Dr. underestimated the risks of obstruction brought about by dairy effluent. The greater susceptibility to clogging occurred in the dripper G2 operating in 1A1E and 3A1E dilutions. On the other hand, the dripper G5 was less susceptible to clogging at operating 2A1E dilution. The screen filter provided good removal of SS with the same size or greater than 130 μm / O problema da crise hídrica está diretamente relacionado com fatores como aumento da população, aumento da demanda por água, variações climáticas e deterioração dos recursos existentes. No semiárido nordestino as características predominantes de índice pluviométrico reduzido, temperatura elevada e alta taxa evaporativa, tornam a escassez de água, por longos períodos do ano, cada vez mais recorrente. Os efluentes líquidos das indústrias de laticínios apresentam potencial para uso agrícola, devido ao aporte de nutrientes. No entanto, esta prática envolve questões relacionadas à viabilidade técnica, inerente ao método de irrigação adotado, onde o entupimento dos emissores se torna a maior vulnerabilidade, mas que pode ser atenuada com a técnica da diluição em água. Diante do exposto, o trabalho objetivou analisar o desempenho hidráulico de unidades gotejadoras aplicando diluições de água residuária de laticínios (ARL) e água de abastecimento público (AA). Para isso, montou-se uma bancada experimental, no Laboratório de Poluição e Degradação do Solo (LPDS) da Universidade Federal Rural do Semi-Árido (UFERSA) câmpus Mossoró-RN, constituída de quatro unidades gotejadoras operando com quatro diferentes diluições de ARL em AA (1A0E; 1A1E; 2A1E e 3A1E) e de cinco tipos de gotejadores (G1; G2; G3; G4 e G5). O desempenho hidráulico das unidades gotejadoras foi obtido a cada 40 h de operação com as diluições de ARL em AA, durante 200 h no período de 20/10 de 2014 a 10/04 de 2015, utilizando-se os indicadores: vazão de gotejadores (Q), coeficiente de variação de vazão (CVQ), coeficiente de uniformidade estatístico (Us), coeficiente de uniformidade de distribuição (CUD) e redução da vazão relativa (Dra). Paralelamente, quantificaram os atributos físico-químicos e microbiológicos das diluições de ARL em AA. Os dados foram submetidos às análises de regressão simples e múltipla e teste de correlações paramétricas de Pearson. Dentre as características físico-químicas e microbiológicas do efluente de laticínios, os valores de sólidos suspensos (SS), sólidos dissolvidos (SD), pH e ferro total (Fe) representaram risco de obstrução de gotejadores que variam de moderado a alto. As características SS, SD, pH e Fe predominaram nas equações de regressão lineares múltiplas ajustadas às variáveis de desempenho hidráulico, para as combinações entre tipos de gotejadores e níveis de diluição do efluente de laticínios em água de abastecimento público. Ao final dos ensaios experimentais, amostras dos emissores com bioincrustação foram submetidas a registros fotográficos e análises por microscopia óptica e eletrônica de varredura (MEV), evidenciando a formação de um biofilme em toda a área interna dos emissores amostrados tendo como consequência o entupimento parcial e total dos gotejadores testados, afetando dessa forma, o desempenho hidráulico do sistema. Os indicadores de desempenho hidráulico Q, CUD, CVQ e Us expressaram satisfatoriamente os níveis de obstrução de gotejadores, enquanto o Dra subestimou os riscos de obstrução acarretado pelo efluente de laticínios. A maior suscetibilidade ao entupimento ocorreu no gotejador G2, operando nas diluições 1A1E e 3A1E. Por outro lado, o gotejador G5 se mostrou menos suscetível ao entupimento operando na diluição 2A1E. O filtro de tela proporcionou boa remoção de SS com tamanhos iguais ou superiores a 130 μm / 2016-11-17
36

Evapotranspiração e coeficientes de cultivo (KC) da cana-de-açúcar irrigada por gotejamento subsuperficial / Evapotranspiration and crop coefficients of subsurface drip irrigated sugar cane

Gonçalves, Fabricio Mota January 2010 (has links)
GONÇALVES, Fabricio Mota. Evapotranspiração e coeficientes de cultivo (KC) da cana-de-açúcar irrigada por gotejamento subsuperficial. 2010. 64 f. Dissertação (Mestrado em engenharia agrícola)- Universidade Federal do Ceará, Fortaleza-CE, 2010. / Submitted by Elineudson Ribeiro (elineudsonr@gmail.com) on 2016-06-21T18:44:18Z No. of bitstreams: 1 2010_dis_fmgoncalves.pdf: 3909193 bytes, checksum: b818df330f21fcd52b71e61d84782c03 (MD5) / Approved for entry into archive by José Jairo Viana de Sousa (jairo@ufc.br) on 2016-07-21T20:13:45Z (GMT) No. of bitstreams: 1 2010_dis_fmgoncalves.pdf: 3909193 bytes, checksum: b818df330f21fcd52b71e61d84782c03 (MD5) / Made available in DSpace on 2016-07-21T20:13:45Z (GMT). No. of bitstreams: 1 2010_dis_fmgoncalves.pdf: 3909193 bytes, checksum: b818df330f21fcd52b71e61d84782c03 (MD5) Previous issue date: 2010 / Sugar cane is one of the crops with the highest level of water consumption, with a high evapotranspiration demand throughout most of its cycle. Knowledge of the sugar cane water demand, the time that irrigation should be applied, and how to irrigate the crop are becoming increasingly important for the sustainable development of irrigated sugar cane cultivation, especially in areas of low water availability, as it is the case in northea stern Brazil. The experiment was carried out at the Curu Experimental Field (property of the Embrapa Tropical Agroindustry), located in the Curu-Paraipaba Irrig ation Project, city of Paraipaba-CE (3 ° 29 '20''S, 39 ° 9' 45''W and elevation 30m), in order to determine the evapotrans piration and crop coefficients (Kc) of sugarcane (Saccharum L. officinarium), subsurface drip-irrigated. It was used the SP 6949 sugar cane variety, planted in a spacing of 1.8 m between double rows and 0.4 m between rows within the double row. As to t he irrigation, we used one lateral water line for each double row, buried at a depth of 0.15 m, w ith self-compensating drip emitters, with a flow rate of 1 L h-1, spaced 0.5 m on the water line. The crop was irrigated daily and there were three fertigations per week. The irrigation de pth was periodically adjusted, keeping the soil water potential between -8 kPa to -20 kPa. The crop evapotranspiration (ETc) was determined using a wei ghing lysimeter with a surface area of 2.25 m 2. The reference evapotranspiration (ETo) was estimated by the FAO Penman-Monteith method. The durations of the phenological stages of cane sugar were estimated through analysis of soil cover, with the use of digital images. Durations of 31, 49, 237 and 118 days were observed, respectively for initial, crop development, mid-season and late season stages. The yields achieved within and outside the lysimeter were respectively 144.4 and 108.8 t ha -1 . The total ETc observed during the cycle of the sugar cane was 1074.1 m m, with maximum values of 6.6 mm d-1 during the mid-season stage. Observed Kc values for initial, mid-season and late season stages were respectively 0.23, 1 .03 and 0.50. In the crop development stage, the relationship between Kc and the (crop) soil cover was represented with good accuracy by a negative quadratic model. / A cana-de-açúcar é uma das culturas com maior consumo de água, apresentando uma alta demanda evapotranspirativa ao longo da maior parte do seu ciclo. O conhecimento das necessidades hídricas da cana-de-açúcar, do momento de aplicação da água requerida pela mesma e a forma de aplicação torna-se cada vez mais importante para o desenvolvimento sustentável da sua produção irrigada, principalmente em regiões de pouca disponibilidade hídrica, como é o caso da região Nordeste do Brasil. O experimento foi conduzido no Campo Experimental do Curu, pertencente à Embrapa Agroindústria Tropical localizado no Perímetro Irrigado Curu-Paraipaba, município de Paraipaba-CE (3° 29’ 20’’ S, 39° 9’ 45’’ W e altitude de 30 m), com o objetivo de determinar a evapotranspiração e os coeficientes de cultivo (Kc) da cana-de-açúcar (Saccharum officinarium L.), irrigada por gotejamento subsuperficial. Utilizou-se a variedade de cana SP 6949, plantada no espaçamento de 1,8 m entre fileiras duplas e 0,4 m entre linhas dentro da fileira dupla. Na irrigação utilizou-se uma linha lateral para cada fileira dupla, enterrada na profundidade de 0,15 m, com gotejadores autocompensantes, com vazão de 1 L h-1, espaçados de 0,5 m na linha. A cultura foi irrigada com freqüência diária e foram realizadas três fertirrigações por semana. A lâmina de irrigação foi ajustada periodicamente, mantendo-se o potencial de água no solo entre -8 kPa e -20 kPa. A evapotranspiração da cultura (ETc) foi determinada utilizando-se um lisímetro de pesagem com área superficial de 2,25 m2. A evapotranspiração de referência (ETo) foi estimada pelo método FAO Penman-Monteith. As durações das fases fenológicas da cana-de-açúcar foram estimadas por meio da análise da cobertura do solo pela cultura, determinada com o uso de imagens digitais. Foram observadas durações de 31, 49, 237 e 118 dias, para as fases inicial, de desenvolvimento, intermediária e final, respectivamente. A produtividade alcançada dentro e fora do lisímetro foi de 144,4 e 108,8 t ha-1, respectivamente. A ETc total observada durante o ciclo da cana-de-açúcar foi de 1.074,1 mm, com valores máximos da ordem de 6,6 mm d-1 durante a fase intermediária. Foram observados valores de Kc iguais a 0,23, 1,03 e 0,50, para as fases inicial, intermediária e final, respectivamente. Na fase de desenvolvimento vegetativo a relação entre o Kc e a cobertura do solo pela cultura foi representada com bastante exatidão por um modelo quadrático negativo.
37

Índice de sustentabilidade do perímetro irrigado Baixo Acaraú-Ceará / Sustainability index in the irrigated Baixo Acaraú -Ceará

Lopes, Fernando Bezerra January 2008 (has links)
LOPES, Fernando Bezerra. Índice de sustentabilidade do perímetro irrigado Baixo Acaraú-Ceará. 2008. 117 f. Dissertação (Mestrado em engenharia agrícola)- Universidade Federal do Ceará, Fortaleza-CE, 2008. / Submitted by Elineudson Ribeiro (elineudsonr@gmail.com) on 2016-06-21T19:03:01Z No. of bitstreams: 1 2008_dis_fblopes.pdf: 8853642 bytes, checksum: 6b9ca35602180a0ed03b7181c5db0396 (MD5) / Approved for entry into archive by José Jairo Viana de Sousa (jairo@ufc.br) on 2016-07-21T20:13:53Z (GMT) No. of bitstreams: 1 2008_dis_fblopes.pdf: 8853642 bytes, checksum: 6b9ca35602180a0ed03b7181c5db0396 (MD5) / Made available in DSpace on 2016-07-21T20:13:53Z (GMT). No. of bitstreams: 1 2008_dis_fblopes.pdf: 8853642 bytes, checksum: 6b9ca35602180a0ed03b7181c5db0396 (MD5) Previous issue date: 2008 / The aimed of this work was an integrated sustainability analysis of the Irrigated Perimeter of Baixo Acaraú (PIBAU) sited in Acaraú basin, Ceará, Brazil. The analysis was labeled by an agro ecological sustainability index (ASI). The approach was based on 22 cross-over form applied to small producers that live in the PIBAU. In the irrigated areas selected to perform the interviews, it was developed the irrigation system evaluation. Factory Analysis/Principal Components Analysis (FA/PCA) was employed to select the factors sustainability indicators of the irrigated perimeter as well as to define the agro ecological sustainability index. Results showed that 64% of the producers had a power education and 77% of them had no experience with irrigation agriculture before. Also, it was identified that only 18% of irrigation systems presented an excellent CUD, while 28% of them were classified with a bad performance. According to the sensitive test effectuated by FA/PCA, only 12 of 27 variables that composed the initial matrix were significant to explain the total variance of data set. The 12 variables selected by the model were grouped in five factors explaining 79.14% of the total variance. The factors loading indicated that the PIBAU sustainability is, principally, related to the lack of acknowledgment as well as the used of suitable management of agricultural practices. The sustainability index of each productive units ranges from 0.283 to 0.916 and the average was 0.538. Only 9.0% of the pooled productivity were classified as sustainable, while 18.2% of them presented a kind of sustainability. Almost the half of producers (45.5%) showed a threatened sustainability and the others (27.3%) were in unsustainable condition. Also, it was identified that some units with a good irrigation system performance, without of salinization risk presented a low sustainability index (0.371). This is explained by the fact the index express an integration of different variables. Even though, no risk of salinization was identified, this work registered an addition high of significance of salt in the irrigated area when compared to undisturbed one. / Este trabalho teve como objetivo realizar uma análise integrada da sustentabilidade do Perímetro Irrigado Baixo Acaraú (PIBAU), localizado na Bacia do Acaraú a norte do Estado do Ceará, possibilitando o desenvolvimento de um índice de sustentabilidade agro-ambiental. Para isso, aplicou-se uma amostragem exploratória, adotando um modelo de amostragem não probabilístico, obtendo uma população amostral de 22 produtores agrícolas beneficiados pelo respectivo projeto de irrigação e aplicando-se questionários do tipo “cross-over”. Nos lotes selecionados para a aplicação dos questionários, foi realizada uma avaliação dos sistemas de irrigação. Os fatores determinantes da sustentabilidade do Perímetro, bem como o índice de sustentabilidade foram identificados pelo emprego da técnica de Análise Fatorial/Análise da Componente Principal (AF/ACP). A pesquisa identificou que mais da metade dos produtores agrícolas apresentam baixo nível educacional (64%) e que 77% dos irrigantes não tinham experiência com a prática da agricultura irrigada antes de ser proprietário de um lote no Perímetro. Apenas 18% dos sistemas de irrigação localizada do Perímetro apresentam Coeficiente de Uniformidade de Distribuição (CUD) classificado como excelente e 28% apresentam CUD classificado como ruim. Pelo teste de sensibilidade, efetuado utilizando-se o modelo da AF/ACP, identificou-se que, das 27 variáveis que compunham a matriz inicial, apenas 12 delas apresentaram alguma significância na explicação da variância total dos dados. O emprego do modelo promoveu a redução de 12 características dos fatores que influenciam a sustentabilidade do Perímetro para cinco componentes, que explicam 79,14% da variância total. Os pesos atribuídos a cada fator indicaram que a sustentabilidade do Perímetro Baixo Acaraú está, principalmente, relacionada à falta de conhecimento e do uso de técnicas corretas de produção agrícola. Os índices de sustentabilidade obtidos para cada unidade produtiva variaram no intervalo de 0,283 a 0,916. A média global de sustentabilidade dos lotes foi de 0,538 representando uma condição de sustentabilidade comprometida. Apenas 9,0% das unidades produtivas estudadas encontram-se numa situação de sustentabilidade equilibrada. Outros 18,2% dos produtores ainda são considerados sustentáveis, mas em condição de ameaça, que pode advir de qualquer um dos fatores contabilizados no índice. Quase metade dos colonos (45,5%) pesquisados registrou uma sustentabilidade que já se apresenta de alguma forma comprometida e os demais (27,3%) estão em condições de insustentabilidade. A unidade produtiva em estudo não apresenta solos com problema de salinização, porém com exceção da camada inferior (0,90 a 1,20 m), para as demais camadas estudadas (0 a 0,30, 0,30 a 0,60 e 0,60 a 0,90 m) a adição de sais ao solo pelo manejo inadequado da irrigação foi altamente significativa. Apesar do solo não apresentar risco de salinização e o sistema de irrigação funcionar com uma uniformidade de distribuirão classificado como bom, a unidade em estudo apresenta índice de sustentabilidade de 0,371, devido o índice ser formado por um conjunto de variáveis.
38

Índice de sustentabilidade do perímetro irrigado Baixo Acaraú-Ceará / Sustainability index in the irrigated Baixo Acaraú -Ceará

Lopes, Fernando Bezerra January 2008 (has links)
LOPES, Fernando Bezerra. Índice de sustentabilidade do perímetro irrigado Baixo Acaraú-Ceará. 2008. 116 f. : Dissertação (mestrado) - Universidade Federal do Ceará, Centro de Ciências Agrárias, Departamento de Engenharia Agrícola, Curso de Mestrado em Agronomia, Fortaleza-CE, 2008. / Submitted by demia Maia (demiamlm@gmail.com) on 2016-06-28T14:53:36Z No. of bitstreams: 1 2008_dis_fblopes.pdf: 8811876 bytes, checksum: 201eefecde686ccd48ca07732060ab33 (MD5) / Approved for entry into archive by demia Maia (demiamlm@gmail.com) on 2016-06-28T14:54:03Z (GMT) No. of bitstreams: 1 2008_dis_fblopes.pdf: 8811876 bytes, checksum: 201eefecde686ccd48ca07732060ab33 (MD5) / Made available in DSpace on 2016-06-28T14:54:03Z (GMT). No. of bitstreams: 1 2008_dis_fblopes.pdf: 8811876 bytes, checksum: 201eefecde686ccd48ca07732060ab33 (MD5) Previous issue date: 2008 / The aimed of this work was an integrated sustainability analysis of the Irrigated Perimeter of Baixo Acaraú (PIBAU) sited in Acaraú basin, Ceará, Brazil. The analysis was labeled by an agro ecological sustainability index (ASI). The approach was based on 22 cross-over form applied to small producers that live in the PIBAU. In the irrigated areas selected to perform the interviews, it was developed the irrigation system evaluation. Factory Analysis/Principal Components Analysis (FA/PCA) was employed to select the factors sustainability indicators of the irrigated perimeter as well as to define the agro ecological sustainability index. Results showed that 64% of the producers had a power education and 77% of them had no experience with irrigation agriculture before. Also, it was identified that only 18% of irrigation systems presented an excellent CUD, while 28% of them were classified with a bad performance. According to the sensitive test effectuated by FA/PCA, only 12 of 27 variables that composed the initial matrix were significant to explain the total variance of data set. The 12 variables selected by the model were grouped in five factors explaining 79.14% of the total variance. The factors loading indicated that the PIBAU sustainability is, principally, related to the lack of acknowledgment as well as the used of suitable management of agricultural practices. The sustainability index of each productive units ranges from 0.283 to 0.916 and the average was 0.538. Only 9.0% of the pooled productivity were classified as sustainable, while 18.2% of them presented a kind of sustainability. Almost the half of producers (45.5%) showed a threatened sustainability and the others (27.3%) were in unsustainable condition. Also, it was identified that some units with a good irrigation system performance, without of salinization risk presented a low sustainability index (0.371). This is explained by the fact the index express an integration of different variables. Even though, no risk of salinization was identified, this work registered an addition high of significance of salt in the irrigated area when compared to undisturbed one. / Este trabalho teve como objetivo realizar uma análise integrada da sustentabilidade do Perímetro Irrigado Baixo Acaraú (PIBAU), localizado na Bacia do Acaraú a norte do Estado do Ceará, possibilitando o desenvolvimento de um índice de sustentabilidade agro-ambiental. Para isso, aplicou-se uma amostragem exploratória, adotando um modelo de amostragem não probabilístico, obtendo uma população amostral de 22 produtores agrícolas beneficiados pelo respectivo projeto de irrigação e aplicando-se questionários do tipo “cross-over”. Nos lotes selecionados para a aplicação dos questionários, foi realizada uma avaliação dos sistemas de irrigação. Os fatores determinantes da sustentabilidade do Perímetro, bem como o índice de sustentabilidade foram identificados pelo emprego da técnica de Análise Fatorial/Análise da Componente Principal (AF/ACP). A pesquisa identificou que mais da metade dos produtores agrícolas apresentam baixo nível educacional (64%) e que 77% dos irrigantes não tinham experiência com a prática da agricultura irrigada antes de ser proprietário de um lote no Perímetro. Apenas 18% dos sistemas de irrigação localizada do Perímetro apresentam Coeficiente de Uniformidade de Distribuição (CUD) classificado como excelente e 28% apresentam CUD classificado como ruim. Pelo teste de sensibilidade, efetuado utilizando-se o modelo da AF/ACP, identificou-se que, das 27 variáveis que compunham a matriz inicial, apenas 12 delas apresentaram alguma significância na explicação da variância total dos dados. O emprego do modelo promoveu a redução de 12 características dos fatores que influenciam a sustentabilidade do Perímetro para cinco componentes, que explicam 79,14% da variância total. Os pesos atribuídos a cada fator indicaram que a sustentabilidade do Perímetro Baixo Acaraú está, principalmente, relacionada à falta de conhecimento e do uso de técnicas corretas de produção agrícola. Os índices de sustentabilidade obtidos para cada unidade produtiva variaram no intervalo de 0,283 a 0,916. A média global de sustentabilidade dos lotes foi de 0,538 representando uma condição de sustentabilidade comprometida. Apenas 9,0% das unidades produtivas estudadas encontram-se numa situação de sustentabilidade equilibrada. Outros 18,2% dos produtores ainda são considerados sustentáveis, mas em condição de ameaça, que pode advir de qualquer um dos fatores contabilizados no índice. Quase metade dos colonos (45,5%) pesquisados registrou uma sustentabilidade que já se apresenta de alguma forma comprometida e os demais (27,3%) estão em condições de insustentabilidade. A unidade produtiva em estudo não apresenta solos com problema de salinização, porém com exceção da camada inferior (0,90 a 1,20 m), para as demais camadas estudadas (0 a 0,30, 0,30 a 0,60 e 0,60 a 0,90 m) a adição de sais ao solo pelo manejo inadequado da irrigação foi altamente significativa. Apesar do solo não apresentar risco de salinização e o sistema de irrigação funcionar com uma uniformidade de distribuirão classificado como bom, a unidade em estudo apresenta índice de sustentabilidade de 0,371, devido o índice ser formado por um conjunto de variáveis.
39

Função de resposta da cultura de meloeiro aos níveis de água e adubação nitogenada no vale do Curu, Ce / Response finction of the melon ti water and nitrogen use, in Curu Valley,Ceará

Monteiro, Rodrigo Otávio Câmara January 2004 (has links)
MONTEIRO, Rodrigo Otávio Câmara. Função de resposta da cultura de meloeiro aos níveis de água e adubação nitogenada no vale do Curu, Ce. 2004. 92 f. Dissertação (Mestrado em engenharia agrícola)- Universidade Federal do Ceará, Fortaleza-CE, 2004. / Submitted by Elineudson Ribeiro (elineudsonr@gmail.com) on 2016-06-28T18:07:55Z No. of bitstreams: 1 2004_dis_rocmonteiro.pdf: 685098 bytes, checksum: 6cb2424a57ac38d0ba91044d97f0109d (MD5) / Approved for entry into archive by José Jairo Viana de Sousa (jairo@ufc.br) on 2016-06-30T23:47:26Z (GMT) No. of bitstreams: 1 2004_dis_rocmonteiro.pdf: 685098 bytes, checksum: 6cb2424a57ac38d0ba91044d97f0109d (MD5) / Made available in DSpace on 2016-06-30T23:47:26Z (GMT). No. of bitstreams: 1 2004_dis_rocmonteiro.pdf: 685098 bytes, checksum: 6cb2424a57ac38d0ba91044d97f0109d (MD5) Previous issue date: 2004 / To study the effect of water, nitrogen and the interaction between these factors on the economic yield and the production components of melon (Cucumis melo L.), a field experiment was carried out in the Experimental Farm Curu Valley, Pentecoste, Ceará, Brazil, from september to december, 2002. The statistical design was completely randomized blocks in split-plots, with four primary treatments, four secondary and four blocks. The main treatments corresponded to four water depths (W1=232,7; W2=334,7; W3=422,1; W4=567,8 mm) with four levels of nitrogen (N0=0; N1=75; N2=150; N3=300 kg.ha-1). The crop used was melon, hybrid AF-646, and the daily irrigations were controlled base on a class “A” evaporation tank, being the treatments W1, W2, W3 and W4, corresponding to 0,35 ECA, 0,70 ECA, 1,0 ECA and 1,5 ECA, respectively. The crop was installed at a 2,0 m x 0,5 m spacing, irrigated by a drip irrigation system with 3,75 L.h-1 emitters, space 0,5 m apart. The results showed that the water presented highly significant effect on the productivity of the melon, while the nitrogen was significant in the level of 6,43% and the interaction among the factors was not significant. The highest productivity estimated with the function was 25496,1 kg.ha- 1, corresponding to an application of 612,1 mm of water and and 224,4 kg.ha-1 of nitrogen. The maximum net income, R$/ha 3.353,24, was achieved with the application of 609,2 mm of water and 186,2 kg.ha-1 of nitrogen., providing an yield of 25384,3 kg.ha-1. The water use efficiency increased with the increasing levels of nitrogen up to the level of N 150 kg.ha-1, decreasing with the level of 300 kg.ha-1, for a maximum observed value of 70,4 kg.ha-1.mm-1 obtained with 232,7 mm of water deph and 150 kg.ha-1 of nitrogen. The economic water use efficiency was estimated as 41,66 kg.ha-1.mm-1, with the application of 186,2 kg.ha-1 of nitrogen. / Estudar o efeito das lâminas de água, doses de nitrogênio e sua interação sobre a produtividade econômica e componentes de produção do melão (Cucumis melo L.), foi o principal objetivo deste trabalho, o qual foi realizado na Fazenda Experimental Vale do Curu, Pentecoste, Ceará, no período de setembro a dezembro de 2002. O delineamento experimental foi em blocos ao acaso com parcelas subdivididas, composto de quatro tratamentos primários nas parcelas, quatro tratamentos secundários nas subparcelas e quatro blocos. Os tratamentos constituíram-se da combinação de quatro lâminas de irrigação (W1=232,7; W2=334,7; W3=422,1; W4=567,8 mm) com quatro níveis de adubação nitrogenada (N0=0; N1=75; N2=150; N3=300 kg. ha-1). Utilizou-se a cultura do melão, híbrido AF-646, irrigações diárias controladas com base na evaporação do tanque classe “A” (ECA), sendo os tratamentos W1, W2, W3 e W4, correspondentes a 0,35 ECA, 0,70 ECA, 1,0 ECA e 1,5 ECA, respectivamente. A cultura foi instalada no espaçamento de 2,0 m x 0,5 m, irrigada por um sistema de irrigação localizado tipo gotejamento, com gotejadores autocompensantes de 3,75 L.h-1 de vazão, espaçados de 0,5 m na linha lateral. Após análise dos resultados verificou-se que o fator água apresentou efeito altamente significativo sobre a produtividade do melão, enquanto que o fator nitrogênio foi significativo em nível de 6,43%, no entanto, interação entre os fatores não foi significativa. A máxima produtividade estimada foi de 25496,1 kg.ha-1, obtida com 612,1 mm de água e 224,4 kg.ha-1 de nitrogênio. A máxima receita líquida estimada de R$/ha 3.353,24 foi obtida com uma produtividade de 25384,3 kg.ha-1 de melão, utilizando-se 609,2 mm de água e 186,2 kg.ha-1 de nitrogênio. Os valores médios da eficiência do uso da água apresentaram correlação positiva com o fator doses de nitrogênio até a dose 150 kg.ha-1, decrescendo, em seguida, com a dose de 300 kg.ha-1, sendo o valor máximo observado de 70,4 kg.ha-1.mm-1 para a combinação de uma lâmina de água de 232,7 mm e uma dose de 150 kg.ha-1 de nitrogênio. Já a eficiência ótima econômica do uso da água estimada foi de 41,66 kg.ha-1.mm-1, para uma dose de 186,2 kg.ha-1 de nitrogênio.
40

Dinâmica de entupimento de gotejadores em função da aplicação de água rica em ferro

Brauer, Rigléia Lima [UNESP] 21 June 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:26:47Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-06-21Bitstream added on 2014-06-13T18:30:34Z : No. of bitstreams: 1 brauer_rl_me_botfca.pdf: 786217 bytes, checksum: fdfb7a5da26b6d788caa4ede1650975d (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Universidade Estadual Paulista (UNESP) / Com o propósito de avaliar a susceptibilidade de dois tipos de gotejadores ao processo de entupimento por ferro, foi conduzido um experimento em uma bancada de ensaios no Laboratório de Ensaio de Equipamentos para Irrigação do Departamento de Engenharia Rural da Universidade Estadual Paulista “Júlio de Mesquita Filho” – Campus de Botucatu. O ensaio corresponde ao processo de entupimento, e foram avaliados os seguintes modelos de gotejadores NaanDanJain: NaanPC laranja e NaanPC azul. Foram utilizados segmentos de tubos, totalizando 25 emissores, onde se mediu a vazão com a pressão de 150 KPa, com três repetições para cada gotejador. A água utilizada no ensaio foi proveniente do lago do Departamento de Engenharia Rural que é comumente utilizado para irrigações de experimentos. Posteriormente foram calculados: Vazão Média, Coeficiente de Variação de Vazão (C.V.Q), Uniformidade de Distribuição da Água (C.U.D), Coeficiente de Uniformidade de Christiansen (C.U.C) e Vazão Relativa (V.R.). Foi utilizado delineamento experimental estatístico de blocos inteiramente casualizados, com fatorial 2x2x7, com três repetições, sendo o primeiro fator os tratamentos com ferro, o segundo fator os tipos de gotejadores e o terceiro fator o tempo. Os resultados obtidos não apontaram diferença significativa nas diferentes doses de ferro. Entretanto, os resultados apontaram diferença significativa na interação gotejador x tempo e coeficiente de uniformidade de Christiansen (CUC) e vazão relativa (V.R.) / The objective of this study was to evaluate the susceptibility of clogging by iron in two types of drippers using a test bank located at the Irrigation Experimental Laboratory in the Department of Agricultural Engineering of “Sao Paulo State University Julio de Mesquita Filho - Campus of Botucatu, Sao Paulo state. The experiment aims to study the clogging process, evaluating 2 models of drippers NaanDanJain: NaanPC orange and NaanPC blue. It was used tube segments, totaling 25 drippers, using pressure of 150 kPa, with 3 repetitions for each dripper. The water used in the test was from the lake of the Department of Agricultural Engineering which is commonly used for irrigation experiments. It was calculated: the average discharge, the variation coefficient of discharge (CVQ), the uniformity coefficient of distribution (CUD), the uniformity coefficient of Christiansen (CUC) and the relative discharge (VR). It was used statistical experimental design of randomized blocks, with a 2x2x7 factorial with three replications, with the first factor treatment with iron, the second factor the types of drippers and the third factor the time. The results showed no significant difference in different doses of iron. However, the results indicated significant differences in drip x time interaction and the Christiansen uniformity coefficient (CUC) and relative discharge rate (VR)

Page generated in 0.2725 seconds