• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 17
  • 7
  • 3
  • 1
  • 1
  • Tagged with
  • 34
  • 7
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

A portable jig for crosscutting and ripping large sheets of paneling

Stump, H. Mark January 1967 (has links)
There is no abstract available for this thesis.
2

O efeito do Jig de Lucia na atividade eletromiográfica dos músculos mastigatórios / The effect of the Lucia\'s Jig on electromyographic activity of masticatory muscles

Nassar, Mariangela Salles Pereira 25 November 2011 (has links)
O reprogramador neuromuscular Jig de Lucia evita que ocorram interferências oclusais, melhorando assim a avaliação das alterações e distúrbios na oclusão. No presente estudo, foram analisados 42 indivíduos dentados saudáveis, portadores de normo oclusão, respiradores nasais, Classe I de Angle, sem hábitos parafuncionais e disfunção temporomandibular, com a idade entre 21 a 40 anos em ambos os gêneros, com o objetivo de avaliar a atividade eletromiográfica dos músculos masseter e temporal, bilateralmente. Os registros eletromiográficos foram realizados com o eletromiógrafo MyoSystem-Br1. A avaliação foi executada antes da instalação do dispositivo de reprogramação neuromuscular na condição postural de repouso e após a sua instalação sobre dentes incisivos centrais superiores (11 e 21), apresentando contato incisal dos incisivos centrais inferiores na porção palatina do dispositivo nos seguintes períodos de tempo:0, 5 \', 10\', 15 \', 20\' e 30\'(minutos). Os dados foram submetidos à análise estatística (SPSS 17.0) com nível de confiança de 95% (p < 0,05). Os resultados evidenciaram alterações da atividade eletromiográfica dos músculos mastigatórios com o uso do Jig de Lucia nos determinados tempos de estudo da pesquisa, mas não havendo diferença estatisticamente significante para todas as comparações efetuadas. Os autores concluíram que o jig de Lucia altera a atividade eletromiográfica, podendo assim levar a uma reprogramação neuromuscular da mandíbula, muito importante para atividade clínica do cirurgião dentista no diagnóstico correto na posição oclusal. / The Lucia\'s Jig neuromuscular reprogramming can eliminate occlusal interferences, thereby improving the evaluation of changes and disturbances in occlusion. In this study, we analyzed 42 healthy dentate subjects, patients with normo-occlusion, nasal breathing, Angle Class I, without deleterious habits and temporomandibular joint dysfunction, with age between 21 to 40 years in both genders, with the aim of evaluating the electromyographic activity of masseter and temporal muscles bilaterally. The electromyographic recordings were performed with the EMG-Br1 Myosystem. The evaluation was performed before placing the device in neuromuscular reprogramming of rest postural condition and after installation in the upper central incisors (11 and 21), incisal one contact the lower central incisor tooth in the palatine portion of the device in following time periods: 0, 5 \', 10\', 15 \'20\' and 30\'(minutes). Data were subjected to statistical analysis (SPSS 17.0) with a confidence level of 95% (p <0.05). The results showed changes in electromyographic activity of masticatory muscles using the Lucia\'s Jig in certain times of the research study, but there was no statistically significant difference for all comparisons. The authors concluded that the Lucia\'s Jig changes electromyographic activity and may thus lead to a neuromuscular reprogramming of the jaw, even very important clinical activity oral surgeon for the correct diagnosis in occlusal position.
3

O efeito do Jig de Lucia na atividade eletromiográfica dos músculos mastigatórios em indivíduos com disfunção temporomandibular muscular / The Lucia Jig Effect on the electomyographic activity of the chewing muscles in individuals suffering from temporomandibular muscular disorder

Pereira, Cintia Piccolo 30 July 2014 (has links)
O Jig de Lucia, considerado um reprogramador neuromuscular é um dispositivo confeccionado nos incisivos centrais superiores e, utilizado na clínica odontológica com finalidade de desocluir os dentes e consequentemente desprogramar o padrão de atividade neuromuscular evitando que ocorram interferências oclusais e, assim, possibilitando a melhor manipulação da mandíbula, como também, possibilitando a avaliação das alterações e distúrbios na oclusão dental. No presente estudo, foram analisados 33 indivíduos dentados saudáveis, portadores de disfunção temporomandibular muscular ou mista, respiradores nasais, com a idade entre 21 a 40 anos em ambos os gêneros, com o objetivo de avaliar a atividade eletromiográfica dos músculos masseter e temporal, bilateralmente antes e após a instalação do Jig de Lúcia por meio dos registros eletromiográficos. Para tanto foi utilizado o eletromiógrafo MyoSystem- Br1 e, a avaliação inicial foi executada antes da instalação do dispositivo de reprogramação neuromuscular na condição postural de repouso e após a sua instalação sobre dentes incisivos centrais superiores, apresentando contato da superfície incisal dos incisivos centrais inferiores na porção palatina do dispositivo nos seguintes períodos de tempo: 0, 5, 10, 15, 20 e 30 minutos. Os dados foram submetidos à análise estatística (SPSS 17.0) com nível de confiança de 95% (p < 0,05). Os resultados não mostraram alterações estatisticamente significativas em todas as situações analisadas eletromiograficamente. / Lucia Jig, deemed as a neuromuscular re-programmer, is a device manufactured on the upper central incisors and, used in Odontology as a means of disoccluding the teeth and, consequently deprogramming the pattern of neuromuscular activity, avoiding occlusal interferences and, therefore, making it better the manipulation of the jaw, as well as allowing the assessment of dental occlusion alterations and disorders . In the present study, we analyzed 33 healthy dentate subjects, both genders, suffering from muscular or mixed temporomandibular disorder, nasal breathers, between 21 and 40 years old, aiming to assess, bilaterally, the electromyographic activity of the masseter and temporal muscles, before and after the installation of Lucia Jig, by means of electromyographic records. In order to do so, the MyoSystem-Br1 electromyograph was used and, the initial assessment was performed before the installation of the neuromuscular re-programming device, in resting posture condition and after its installation on the upper central incisors, showing contact of the incisal surface of the lower central incisors on the palate portion of the device on the following time periods: 0, 5, 10, 15, 20 and 30 minutes. The data were submitted to statistical analysis ( SPSS 17.0) with 95% confidence level ( p < 0.05). The results showed no statistical significant alterations in all electromyographically analyzed situations.
4

O efeito do Jig de Lucia na atividade eletromiográfica dos músculos mastigatórios / The effect of the Lucia\'s Jig on electromyographic activity of masticatory muscles

Mariangela Salles Pereira Nassar 25 November 2011 (has links)
O reprogramador neuromuscular Jig de Lucia evita que ocorram interferências oclusais, melhorando assim a avaliação das alterações e distúrbios na oclusão. No presente estudo, foram analisados 42 indivíduos dentados saudáveis, portadores de normo oclusão, respiradores nasais, Classe I de Angle, sem hábitos parafuncionais e disfunção temporomandibular, com a idade entre 21 a 40 anos em ambos os gêneros, com o objetivo de avaliar a atividade eletromiográfica dos músculos masseter e temporal, bilateralmente. Os registros eletromiográficos foram realizados com o eletromiógrafo MyoSystem-Br1. A avaliação foi executada antes da instalação do dispositivo de reprogramação neuromuscular na condição postural de repouso e após a sua instalação sobre dentes incisivos centrais superiores (11 e 21), apresentando contato incisal dos incisivos centrais inferiores na porção palatina do dispositivo nos seguintes períodos de tempo:0, 5 \', 10\', 15 \', 20\' e 30\'(minutos). Os dados foram submetidos à análise estatística (SPSS 17.0) com nível de confiança de 95% (p < 0,05). Os resultados evidenciaram alterações da atividade eletromiográfica dos músculos mastigatórios com o uso do Jig de Lucia nos determinados tempos de estudo da pesquisa, mas não havendo diferença estatisticamente significante para todas as comparações efetuadas. Os autores concluíram que o jig de Lucia altera a atividade eletromiográfica, podendo assim levar a uma reprogramação neuromuscular da mandíbula, muito importante para atividade clínica do cirurgião dentista no diagnóstico correto na posição oclusal. / The Lucia\'s Jig neuromuscular reprogramming can eliminate occlusal interferences, thereby improving the evaluation of changes and disturbances in occlusion. In this study, we analyzed 42 healthy dentate subjects, patients with normo-occlusion, nasal breathing, Angle Class I, without deleterious habits and temporomandibular joint dysfunction, with age between 21 to 40 years in both genders, with the aim of evaluating the electromyographic activity of masseter and temporal muscles bilaterally. The electromyographic recordings were performed with the EMG-Br1 Myosystem. The evaluation was performed before placing the device in neuromuscular reprogramming of rest postural condition and after installation in the upper central incisors (11 and 21), incisal one contact the lower central incisor tooth in the palatine portion of the device in following time periods: 0, 5 \', 10\', 15 \'20\' and 30\'(minutes). Data were subjected to statistical analysis (SPSS 17.0) with a confidence level of 95% (p <0.05). The results showed changes in electromyographic activity of masticatory muscles using the Lucia\'s Jig in certain times of the research study, but there was no statistically significant difference for all comparisons. The authors concluded that the Lucia\'s Jig changes electromyographic activity and may thus lead to a neuromuscular reprogramming of the jaw, even very important clinical activity oral surgeon for the correct diagnosis in occlusal position.
5

O efeito do Jig de Lucia na atividade eletromiográfica dos músculos mastigatórios em indivíduos com disfunção temporomandibular muscular / The Lucia Jig Effect on the electomyographic activity of the chewing muscles in individuals suffering from temporomandibular muscular disorder

Cintia Piccolo Pereira 30 July 2014 (has links)
O Jig de Lucia, considerado um reprogramador neuromuscular é um dispositivo confeccionado nos incisivos centrais superiores e, utilizado na clínica odontológica com finalidade de desocluir os dentes e consequentemente desprogramar o padrão de atividade neuromuscular evitando que ocorram interferências oclusais e, assim, possibilitando a melhor manipulação da mandíbula, como também, possibilitando a avaliação das alterações e distúrbios na oclusão dental. No presente estudo, foram analisados 33 indivíduos dentados saudáveis, portadores de disfunção temporomandibular muscular ou mista, respiradores nasais, com a idade entre 21 a 40 anos em ambos os gêneros, com o objetivo de avaliar a atividade eletromiográfica dos músculos masseter e temporal, bilateralmente antes e após a instalação do Jig de Lúcia por meio dos registros eletromiográficos. Para tanto foi utilizado o eletromiógrafo MyoSystem- Br1 e, a avaliação inicial foi executada antes da instalação do dispositivo de reprogramação neuromuscular na condição postural de repouso e após a sua instalação sobre dentes incisivos centrais superiores, apresentando contato da superfície incisal dos incisivos centrais inferiores na porção palatina do dispositivo nos seguintes períodos de tempo: 0, 5, 10, 15, 20 e 30 minutos. Os dados foram submetidos à análise estatística (SPSS 17.0) com nível de confiança de 95% (p < 0,05). Os resultados não mostraram alterações estatisticamente significativas em todas as situações analisadas eletromiograficamente. / Lucia Jig, deemed as a neuromuscular re-programmer, is a device manufactured on the upper central incisors and, used in Odontology as a means of disoccluding the teeth and, consequently deprogramming the pattern of neuromuscular activity, avoiding occlusal interferences and, therefore, making it better the manipulation of the jaw, as well as allowing the assessment of dental occlusion alterations and disorders . In the present study, we analyzed 33 healthy dentate subjects, both genders, suffering from muscular or mixed temporomandibular disorder, nasal breathers, between 21 and 40 years old, aiming to assess, bilaterally, the electromyographic activity of the masseter and temporal muscles, before and after the installation of Lucia Jig, by means of electromyographic records. In order to do so, the MyoSystem-Br1 electromyograph was used and, the initial assessment was performed before the installation of the neuromuscular re-programming device, in resting posture condition and after its installation on the upper central incisors, showing contact of the incisal surface of the lower central incisors on the palate portion of the device on the following time periods: 0, 5, 10, 15, 20 and 30 minutes. The data were submitted to statistical analysis ( SPSS 17.0) with 95% confidence level ( p < 0.05). The results showed no statistical significant alterations in all electromyographically analyzed situations.
6

Análise técnica de alternativas de pré-concentração para o minério de zinco silicatado de Vazante/MG. / Technical analysis of pre-concentration alternatives for the silicate zinc ore from Vazante/MG.

José Neto, Dimas 24 January 2019 (has links)
A pré-concentração consiste no descarte prévio de uma fração da ganga liberada, ou parcialmente liberada, com pouco ou nenhum conteúdo de interesse, antes da alimentação da usina. Tal prática pode levar a uma série de benefícios nas operações subsequentes, como redução do consumo de energia por tonelada de metal produzido, nos casos em que o material rejeitado apresentar WI (work Index) elevado; diminuição do desgaste abrasivo, quando a ganga rejeitada exibir AI (Abrasion Index) alto; além de aumento de recuperação na flotação e eliminação de flutuações no teor da alimentação. Neste sentido, a pré-concentração diminui custos operacionais e aumenta a rentabilidade da usina. Este trabalho teve por objetivo avaliar a aplicabilidade de pré-concentração para o minério de zinco silicatado de Vazante/MG. Em uma primeira etapa foram executados estudos de liberação da ganga no produto de britagem, explorando as propriedades luminescentes do minério. Para isto, imagens de contraste de cores luminescentes foram obtidas e tratadas no Image J. Obteve-se um valor de liberação da ganga da ordem de 85%. Em um segundo momento, foi investigado o desempenho de técnicas de separação densitária e seleção por sensores (ou ore sorting) como alternativas para a pré-concentração do minério de zinco e remoção de ganga carbonática, para isto, foram utilizados ensaios de afunda/flutua em líquidos densos, que simularam uma operação em meio denso, estratificação em jigue e ensaios em sorter com sensor de transmissão de Raios-X de energia dupla (DE- XRT). O melhor resultado foi obtido através do ensaio de afunda/flutua com densidade de separação de 2,95 g/cm³, no qual foi alcançado um descarte de 30% da massa de alimentação como produto flutuado, numa fração -25 +1,18 mm, removendo 60% dos carbonatos (CaO e MgO) e perdendo apenas 2% de zinco. Os ensaios do sorter também apresentaram resultados positivos, com aproximadamente 93% de recuperação metalúrgica de zinco e um descarte de aproximadamente 30% da massa, mas com uma perda de zinco considerável (aproximadamente 5% em teor). Para a jigagem, os resultados indicaram teor de zinco muito elevado no rejeito (aproximadamente 6%). Entretanto, uma jigagem adicional, realizada com uma segunda amostra numa granulometria menor (-12,7 +1,18 mm), proporcionou menores níveis de zinco perdido para o rejeito, apenas 3,6% em teor. Os impactos da pré-concentração na moagem e flotação também foram avaliados. Para isto foram executados ensaios de work index (WI), abrasion index (AI) e flotação com material tal qual (sem passar por pré-concentração) e com o material pré-concentrado de forma a se ter um comparativo. Como não houve variação de WI e nem de AI entre as amostras tal qual e pré-concentrada, a pré-concentração previamente à moagem, não irá impactar no consumo energético e tampouco no desgaste abrasivo, isto se for adotada a estratégia de manter a mesma vazão mássica de alimentação do circuito de moagem para ambas as alternativas. Em linhas gerais, a flotação após a pré-concentração aumentou a produção de concentrado de zinco com uma qualidade superior em termos de recuperação deste metal. Outro impacto positivo observado foi a redução da quantidade de rejeito fino de flotação e, consequentemente, o volume a ser estocado em barragem. / Preconcentration consists of the prior disposal of a fraction of the liberated or partially liberated gangue with low or no content of interest material before plant feed. Such practice can lead to a number of benefits in subsequent operations, such as reducing energy consumption per ton of metal produced, in cases where the rejected material presents a high WI (work index); decreased abrasive wear when the rejected presents high Abrasion Index (AI); increased recovery in flotation and elimination of fluctuations in feed content. Therefore, preconcentration reduces operating costs and increases the profitability of the plant. This work had the objective of evaluating the preconcentration applicability for a silicate zinc ore from Vazante/MG. In the first stage, grind release tests were performed on the crushing product, exploring the luminescent properties of the ore. For this, luminescent color contrast images were obtained and treated in Image J. A gangue release value of the order of 85% was obtained. Second, the performance of densification separation and sensor sorting (or ore sorting) techniques were investigated as alternatives for preconcentration of zinc ore and removal of carbonate gangue, for this, sink/float tests in dense liquids were used to simulate a dense medium operation, as well jig stratification and sorter tests with dual energy X-ray transmission sensor (DE-XRT). The best result was obtained by the sink/float test with separation density of 2.95 g / cm³, in which a 30% discard of the feed mass as a flotation product was achieved, in a fraction -25 +1.18 mm, removing 60% of the carbonates (CaO and MgO) and losing only 2% of zinc. The sorter tests also showed positive results, with approximately 93% metallurgical recovery and a discard of approximately 30% of the mass, but with a considerable loss of zinc. For jigging, the results indicated very high zinc content in the tailings (approximately 6%). However, additional jigging, performed with a second sample at a smaller particle size (-12.7 +1.18 mm), resulted in lower levels of zinc lost to the tailings, only 3.6% in content. The impacts of preconcentration on milling and flotation were also evaluated. For this, work index (WI), abrasion index (AI) and flotation tests were carried out with the material without preconcentration and with the preconcentrated material in order to compare. As there was no variation of WI and AI between the samples, the preconcentration prior to milling will not impact on energy consumption or on abrasive wear, if the strategy of maintaining the same mass flow rate of the milling circuit for both alternatives is adopted. In general terms, flotation followed by a preconcentration strategy can increase zinc production without requiring expansion of the plant\'s capacity. Another positive impact was the reduction of the amount of fine flotation tailings.
7

Architecture of materialism: A study of craft in design culture, process, and product

Mahaffey, Logan 01 June 2009 (has links)
It is estimated ten thousand hours of experience are required to master any given process (Sennett 20). Whether it is wood joinery, music, culinary arts or weaving, it is about making something that can be seen, heard, touched, and/or used. Society seems to be losing an appreciation for craft as an idea. Especially in the US, materialism has reduced quality and craftsmanship to merely a luxury to those that can afford a $10,000 Maloof chair or an $8000 Amish table. Developers build for maximum profit while buyers seek maximum square footage. Yet it seems while mainstream society continues to "progress", the craftsmen see their clients loss comprehension and appreciation of true quality in their workmanship. While many schools and guilds around the country aim to keep "the crafts", i.e. material-based mediums alive, each craft brings potential processes and applications to the architectural realm. While the architect's general role is to be the conductor of these mediums, he should also study them as a source for potential material and building processes. The art of boatbuilding, glassblowing, ceramics and others each hold something unique to be implemented into architecture. While it is not yet clear what this thesis will turn out to be, as far as program or building type, the goal is the study of craftsmanship of all the different arts and how it can be translated into an architect's design process as well as his product.
8

Comparison of Vertical Misfit Between Pattern Resin and Welded Titanium Used to Fabricate Complete-Arch Implant Verification Jigs

Johnston, Geoffrey R. 27 October 2017 (has links)
No description available.
9

Návrh ohýbacího přípravku pro tenké plechy / Design jig bending of thin sheets

Šrotíř, Petr January 2013 (has links)
The aim of this master´s thesis is the design, proposal and production of a functional jig for technological testing of metal sheet by bending in the pre-production stage to the limit bend radius of the steel sheet up to a thickness of 2 mm, or in case of non-ferrous metal to a thickness of 3 mm. The required bending angle is in the range from zero to ninety degrees. The functionality of the jig will be verified by a practical testing of springing. The proposal will be supported by technological and economic calculations and technical - economic evaluation.
10

Contribution à l'étude expérimentale des écoulements confinés à surfaces libres : application à l'interaction fluide-structure dans un compartiment de JIG artisanal / Contribution to the experimental study of flows confined to free surface : application to the fluid-structure interaction in an artisanal JIG compartment

Randrianantenaina, Cyriaque Donat 13 December 2016 (has links)
Le travail réalisé dans le cadre de cette thèse en co-tutelle concerne deux domaines d’étude de l'interaction fluide-structure. Le premier relevant du Génie Minier traite de l'interaction entre une grille mobile au sein d'un sluice et de l'écoulement confiné associé. Le second relevant de l'Hydrodynamique fondamentale porte sur l'interaction d'un cylindre monté sur appuis souples et un écoulement à surface libre en présence de fond. Notre travail contribue à l’étude des écoulements confinés à surface libre par une approche expérimentale. Nous avons couplé des techniques de visualisation par caméra CCD, de mesures de champs de vitesse par PIV et d'efforts hydrodynamiques pour qualifier la dynamique des objets en mouvement dans l'écoulement. Les méthodes et dispositifs expérimentaux sont alors appliqués à l'étude de l'écoulement autour de deux maquettes simplifiées d'un JIG à grille mobile puis à celui du cylindre vibrant sous l'effet de l'écoulement. L’acquisition par PIV suivi des traitements statistique multi-variables par POD nous a permis d'étudier l'évolution des zones de recirculation dans le compartiment ainsi que le champ de vitesse instationnaire. L’étude expérimentale a été complétée par une simulation numérique par ANSYS14.5 pour la maquette de JIG et par un modèle numérique d’oscillation du sillage pour le cylindre. Ces travaux nous ont permis de mettre en évidence une technique simple pour mettre en mouvement, dans un sluice, un filet attaché à un cylindre et d'étudier les effets du confinement sur un cylindre vibrant en présence de surface libre. / The work realized under this co-supervised thesis concerns two study areas of fluid-structure interaction. The first concerned the Mineral Engineering and deals with the interaction between a moving grate in a sluice and the confined flow associated. The second concerns the fundamental Hydrodynamics and deals with the interaction of a cylinder mounted on flexible supports and a free surface flow in presence of plane wall. Our work contributes to the study a confined free surface flow by experimental approach. We coupled techniques of CCD camera visualization, velocity fields measurements by PIV and hydrodynamic forces to qualify the dynamics of structure motion in the flow. Experimental methods and devices are applied to the study the flow around two simplified models of a moving JIG grate and then to study a vibrating cylinder due to flow. Treatments of PIV data acquisitions by multivariable statistical POD enabled us to describe evolution of recirculation zones in the compartment and unsteady velocity field. Experimental study was completed by a numerical simulation of Jig model by using ANSYS14.5 and a numerical wake oscillator model for the case of the cylinder. This work highlighted a simple technique to give motion, in a sluice, a attached net to a cylinder and to study effects of free surface flow confinement on a vibrating cylinder

Page generated in 0.0381 seconds