Spelling suggestions: "subject:"coelho/cirurgia"" "subject:"joelho/cirurgia""
11 |
Estudo comparativo, em cadáveres, da determinação dos pontos isométricos para a reconstrução do ligamento cruzado anterior do joelho com e sem navegação / Surgery computer assisted, Anterior cruciate ligament/surgery, Comparative study, Cadaver, Knee/surgery, ArthroscopyAngelini, Fabio Janson 11 February 2009 (has links)
INTRODUÇÃO: A precisão no posicionamento dos túneis ósseos na reconstrução do ligamento cruzado anterior do joelho (LCA) é considerado um dos fatores fundamentais para o bom resultado dessa cirurgia. A cirurgia ortopédica auxiliada por computador (computer aided orthopedic surgery CAOS) é um avanço tecnológico que tem como um dos principais objetivos exatamente o aumento da precisão. OBJETIVO: comparar o posicionamento do centro dos túneis e a isometria do enxerto obtidos com o uso de um sistema de navegação computadorizada (Orthopilot) e com o uso de guias cirúrgicos convencionais. MÉTODOS: 36 joelhos pareados de cadáveres tiveram o LCA ressecado por artroscopia no Laboratório de Artroscopia do Departamento de Ortopedia e Traumatologia da Faculdade de Medicina da Universidade de São Paulo. Um joelho de cada par foi ramdomizado para o grupo 1 (guias cirúrgicos convencionais) e o outro para o grupo 2 (Orthopilot). Um fio de sutura inelástico foi passado pelo centro dos túneis tibial e femoral confeccionados para a reconstrução do LCA, sem que os túneis fossem finalmente brocados. Todos os joelhos foram então analisados quanto ao posicionamento do centro do túnel tibial (distância do LCP, distância da tubérculo intercondilar medial da tíbia e distância do corno anterior do menisco lateral), do centro do túnel femoral (distância da cortical posterior e angulação coronal na fossa intercondilar do fêmur) e a variação da distância entre os pontos centrais do túnel femoral para o túnel tibial em flexão de 90º e em extensão (isometria). Os dados foram analisados segundo o teste de Wilcoxon para comparação de duas amostras pareadas. RESULTADOS: A variação da distância entre o tunel femoral e tibial em flexão e extensão (isometria) foi maior no grupo 1 convencional, do que no grupo 2 Orthopilot (grupo 1: média 4,2mm com intervalo de 1,1mm a 9,4mm versus grupo 2: média 2,8mm com intervalo de 0,3mm a 6,7mm; p<0,05). Os outros parâmetros analisados não tiveram diferença estatística entre os grupos e demonstraram que todos os túneis dos dois grupos estavam bem posicionados de acordo com os critérios adotados. CONCLUSÕES: O emprego de instrumental cirúrgico navegado pelo sistema Orhtopilot permitiu o posicionamento dos túneis ósseos da reconstrução do LCA de maneira tão precisa quanto os guias cirúrgicos convencionais utilizados. Mais do que isso, proporcionou um posicionamento significativamente mais isométrico nessa série / INTRODUCTION: Precise tunnel location has been considered to be very important to achieve good results in anterior cruciate ligament (ACL) reconstruction surgery. Computer Aided Orthopedic Surgery (CAOS) is a technology improvement whose main objective is to enhance precision. PURPOSE: To compare the accuracy of tunnel placement and graft isometry for ACL reconstruction performed with the use of a computer-assisted navigation system (Orthopilot) and with traditional instruments. METHODS: 36 matched-paired cadaveric knees had their intact ACL removed by arthroscopy at the Arthroscopy Laboratory Orthopedic Department of University of São Paulo Medical School. One knee of each pair was randomized to group 1 (traditional instruments) or group 2 (Orthopilot). An inelastic suture was then passed through the center of where would be the tibial tunnel and then through the center of where would be the femoral tunnel. None of the tunnels were actually drilled. All knees were then dissected and 6 parameters were obtained: The distance from the tibial tunnel center to: 1) the PCL; 2) the lateral meniscus anterior horn; 3) the medial tibial spine. 4) The distance from the femoral tunnel center to the posterior femoral cortex. 5) The femoral tunnel coronal angle. 6) The variation of the distance from the femoral to the tibial tunnels with the knee extended and in 90 degree flexion. The data were submitted to statistical analysis and compared with the Wilcoxon Matched Pairs Test. RESULTS: The variation of the distance from the femoral to the tibial tunnels in flexion and extension was smaller in the Orthopilot group (better isometry): group 1: mean 4.2 mm (1.1-9.4 mm); group 2: mean 2.8 mm (0.3-6.7 mm) p<0,05. All other parameters showed no statistical difference between the groups and all tunnels were considered to be in satisfactory positions. DISCUSSION: There was no difference in tunnel position between the groups. Better isometry was achieved in the Orthopilot group compared to conventional instruments
|
12 |
Estudo comparativo, em cadáveres, da determinação dos pontos isométricos para a reconstrução do ligamento cruzado anterior do joelho com e sem navegação / Surgery computer assisted, Anterior cruciate ligament/surgery, Comparative study, Cadaver, Knee/surgery, ArthroscopyFabio Janson Angelini 11 February 2009 (has links)
INTRODUÇÃO: A precisão no posicionamento dos túneis ósseos na reconstrução do ligamento cruzado anterior do joelho (LCA) é considerado um dos fatores fundamentais para o bom resultado dessa cirurgia. A cirurgia ortopédica auxiliada por computador (computer aided orthopedic surgery CAOS) é um avanço tecnológico que tem como um dos principais objetivos exatamente o aumento da precisão. OBJETIVO: comparar o posicionamento do centro dos túneis e a isometria do enxerto obtidos com o uso de um sistema de navegação computadorizada (Orthopilot) e com o uso de guias cirúrgicos convencionais. MÉTODOS: 36 joelhos pareados de cadáveres tiveram o LCA ressecado por artroscopia no Laboratório de Artroscopia do Departamento de Ortopedia e Traumatologia da Faculdade de Medicina da Universidade de São Paulo. Um joelho de cada par foi ramdomizado para o grupo 1 (guias cirúrgicos convencionais) e o outro para o grupo 2 (Orthopilot). Um fio de sutura inelástico foi passado pelo centro dos túneis tibial e femoral confeccionados para a reconstrução do LCA, sem que os túneis fossem finalmente brocados. Todos os joelhos foram então analisados quanto ao posicionamento do centro do túnel tibial (distância do LCP, distância da tubérculo intercondilar medial da tíbia e distância do corno anterior do menisco lateral), do centro do túnel femoral (distância da cortical posterior e angulação coronal na fossa intercondilar do fêmur) e a variação da distância entre os pontos centrais do túnel femoral para o túnel tibial em flexão de 90º e em extensão (isometria). Os dados foram analisados segundo o teste de Wilcoxon para comparação de duas amostras pareadas. RESULTADOS: A variação da distância entre o tunel femoral e tibial em flexão e extensão (isometria) foi maior no grupo 1 convencional, do que no grupo 2 Orthopilot (grupo 1: média 4,2mm com intervalo de 1,1mm a 9,4mm versus grupo 2: média 2,8mm com intervalo de 0,3mm a 6,7mm; p<0,05). Os outros parâmetros analisados não tiveram diferença estatística entre os grupos e demonstraram que todos os túneis dos dois grupos estavam bem posicionados de acordo com os critérios adotados. CONCLUSÕES: O emprego de instrumental cirúrgico navegado pelo sistema Orhtopilot permitiu o posicionamento dos túneis ósseos da reconstrução do LCA de maneira tão precisa quanto os guias cirúrgicos convencionais utilizados. Mais do que isso, proporcionou um posicionamento significativamente mais isométrico nessa série / INTRODUCTION: Precise tunnel location has been considered to be very important to achieve good results in anterior cruciate ligament (ACL) reconstruction surgery. Computer Aided Orthopedic Surgery (CAOS) is a technology improvement whose main objective is to enhance precision. PURPOSE: To compare the accuracy of tunnel placement and graft isometry for ACL reconstruction performed with the use of a computer-assisted navigation system (Orthopilot) and with traditional instruments. METHODS: 36 matched-paired cadaveric knees had their intact ACL removed by arthroscopy at the Arthroscopy Laboratory Orthopedic Department of University of São Paulo Medical School. One knee of each pair was randomized to group 1 (traditional instruments) or group 2 (Orthopilot). An inelastic suture was then passed through the center of where would be the tibial tunnel and then through the center of where would be the femoral tunnel. None of the tunnels were actually drilled. All knees were then dissected and 6 parameters were obtained: The distance from the tibial tunnel center to: 1) the PCL; 2) the lateral meniscus anterior horn; 3) the medial tibial spine. 4) The distance from the femoral tunnel center to the posterior femoral cortex. 5) The femoral tunnel coronal angle. 6) The variation of the distance from the femoral to the tibial tunnels with the knee extended and in 90 degree flexion. The data were submitted to statistical analysis and compared with the Wilcoxon Matched Pairs Test. RESULTS: The variation of the distance from the femoral to the tibial tunnels in flexion and extension was smaller in the Orthopilot group (better isometry): group 1: mean 4.2 mm (1.1-9.4 mm); group 2: mean 2.8 mm (0.3-6.7 mm) p<0,05. All other parameters showed no statistical difference between the groups and all tunnels were considered to be in satisfactory positions. DISCUSSION: There was no difference in tunnel position between the groups. Better isometry was achieved in the Orthopilot group compared to conventional instruments
|
13 |
Integração do tendão do músculo semitendíneo na reconstrução do ligamento cruzado anterior: estudo biomecânico, histológico e ressonância magnética em coelhos / The incorporation of the semitendinous tendon autograft at the femoral femoral bone tunnel after anterior cruciate ligament reconstrcuction in rabbits: biomechanical histology and magnetic resonance image analysisPaulo Paes Pereira 05 December 2006 (has links)
O estudo analisa experimentalmente a integração tendinosa no túnel ósseo femoral na reconstrução do ligamento cruzado anterior do joelho esquerdo com o tendão do músculo semitendíneo autólogo, utilizando imagens de ressonância magnética, teste biomecânico e análise histológica em 15 coelhos da raça Nova Zelândia. Após os períodos de quatro, oito e doze semanas do procedimento cirúrgico, os animais foram submetidos ao exame de ressonância magnética para avaliar o túnel femoral dos joelhos. A seguir os animais foram eutanasiados e os joelhos foram submetidos a testes de tração em uma máquina de ensaios mecânicos Kratos para verificar a integração do enxerto nos túneis e a exame histológico do túnel femoral. A análise dos resultados demonstrou integração mecânica do tendão no túnel femoral a partir da 4ª semana em todos os animais estudados e observou-se na histologia e nas imagens da ressonância magnética alterações do enxerto e da área ao redor de forma heterogênea, sugerindo um processo de cicatrização do tendão-osso, porém não se pode afirmar que ocorria a integração até a 12 semanas. / The purpose was to verify the incorporation (healing) of the graft of the semitendinous tendon into the femoral bone tunnel after an anterior cruciate ligament reconstruction, and verify the post operative evolution of the biomechanical histology and magnetic resonance image analysis of the graft into the femoral bone tunnel. Fifteen New Zealand white rabbits were submitted to an intra-articular anterior cruciate ligament reconstruction in the left knee, using semitendinous tendon autograft. The rabbits were submitted to an magnetic resonance image at 4, 8 and 12 weeks after surgery, after which they were euthanized. The left knee of each rabbit was disarticulated and the anterior cruciate ligament reconstruction was tested for the biomechanical properties and histological analysis of the femoral tunnel. Every rabbit knee showed incorporation of the tendon at the femoral tunnel as of the fourth week in all of the knees studied. After the fourth week signs of integration occurred in the histological analysis and heterogeneous alterations in the magnetic resonance image of the graft and the surrounding areas, which suggests a healing process. Despite the biomechanical incorporation of the graft in the femoral bone tunnel after the fourth week it was not possible to affirm that there occurred incorporation of the graft until the completion of 12 weeks in histological and magnetic resonance image analysis.
|
14 |
Uso do fixador externo articulado no tratamento cirúrgico da instabilidade multiligamentar crônica do joelho / Articuled external fixator for treatment of the chronic multiple ligament-injured kneeAngelini, Fabio Janson 29 April 2015 (has links)
INTRODUÇÃO: A instabilidade multiligamentar do joelho, normalmente, é provocada por um trauma que determina sua luxação, um evento pouco frequente, mas, que pode trazer sequelas devastadoras. Mesmo com o tratamento cirúrgico preconizado é alto o índice de complicações. A mobilização precoce no pósoperatório provoca afrouxamento dos ligamentos reconstruídos, o que leva à instabilidade residual. A imobilização melhora a estabilidade, mas provoca dor e rigidez. Este trabalho tem o objetivo de avaliar se o uso do fixador externo articulado proporciona melhora na mobilidade, estabilidade e na função subjetiva de pacientes submetidos à reconstrução ligamentar. MÉTODOS: Neste ensaio clínico randomizado com grupos paralelos, 33 pacientes do ambulatório do Instituto de Ortopedia e Traumatologia do Hospital das Clínicas da Universidade de São Paulo com mais que 3 semanas de lesão dos ligamentos cruzados anterior e posterior associado à lesão de ligamento colateral fibular e/ ou ligamento colateral tibial foram submetidos à cirurgia de reconstrução multiligamentar, após alocação cega aleatória ao grupo 0 - controle (18 pacientes), com órtese rígida ou ao grupo 1 - fixador externo articulado por 6 semanas (15 pacientes), no período entre novembro de 2010 e novembro de 2013. Após seguimento mínimo de um ano de pós-operatório, a estabilidade dos ligamentos reconstruídos foi avaliada ao exame físico, foram mensurados os déficits de extensão e de flexão residual em relação ao joelho contralateral não acometido e foi aplicado o questionário específico para sintomas do joelho de Lysholm. RESULTADOS: Não houve diferença na avaliação da estabilidade articular nem na extensão entre os grupos. No grupo 1, o déficit de flexão passiva foi menor (4,8º +- 5,4º contra 18,2 +- 14,8º, p < 0,05) com mais pacientes, obtendo déficit de flexão considerado normal, de até 5º (64% contra 18%, p < 0,05) e com classificação excelente ou boa no questionário de Lysholm (73% contra 35%, p < 0,05). CONCLUSÕES: Comparado ao protocolo de reabilitação com órtese rígida removível, o uso do fixador externo articulado no tratamento cirúrgico das lesões multiligamentares do joelho proporciona os mesmos resultados de estabilidade ligamentar, aumenta a amplitude de movimento final, com manutenção da extensão e redução do déficit de flexão e proporciona melhores resultados funcionais / INTRODUCTION: Multiligament knee instability is normally caused by a trauma which results in its dislocation, an infrequent event, but one which can have devastating aftereffects. Even with the recommended surgical treatment the rate of complications is high. Early post-operative mobilization provokes loosening of the reconstructed ligaments, which leads to residual instability. Immobilization improves the stability, but causes pain and stiffness. This study aims to assess whether the use of an articulated external fixator provides improvements in the mobility, stability and the subjective function of the patients submitted to ligament reconstruction. METHODS: In this randomized clinical trial with parallel groups, 33 patients of the outpatient clinic of the Institute of Orthopaedics and Traumatology of the Hospital das Clínicas of the University of Sao Paulo with more than 3 weeks of injury to the anterior cruciate ligaments and the posterior cruciate ligaments associated with injury to the fibular collateral ligament and/or medial collateral ligament, were submitted to multiligament reconstruction surgery, after blind random allocation to either: Group 0 - control (18 patients), with rigid bracing, or to Group 1 - articulated external fixator for 6 weeks (15 patients), in the period from November, 2010 to November 2013. The stability of the reconstructed ligaments were assessed after 1 year postoperatively by physical examination, the deficit of residual extension and flexion was measured in relation to the unaffected contralateral knee and the Lysholm knee scoring scale questionnaire was applied. RESULTS: There was no difference in the assessment of joint stability or of the extension between the groups. In group 1 the passive flexion deficit was less (4.8º +- 5.4º versus 18.2 +- 14.8º, p<0.05) with more patients obtaining a flexion deficit considered normal, or up to 5º (64% versus 18%, p<0.05) and with excellent or good classification in the Lysholm knee scoring scale questionnaire (73% versus 35%, p<0.05). CONCLUSIONS: Compared to the rehabilitation protocol with removable rigid bracing, the use of an articulated external fixator in the treatment of multiligament knee injuries provides equal results for ligament stability, increases the amplitude of the Range of Motion, maintains the extension and reduces the flexion deficit, and provides better functional result
|
15 |
Uso do fixador externo articulado no tratamento cirúrgico da instabilidade multiligamentar crônica do joelho / Articuled external fixator for treatment of the chronic multiple ligament-injured kneeFabio Janson Angelini 29 April 2015 (has links)
INTRODUÇÃO: A instabilidade multiligamentar do joelho, normalmente, é provocada por um trauma que determina sua luxação, um evento pouco frequente, mas, que pode trazer sequelas devastadoras. Mesmo com o tratamento cirúrgico preconizado é alto o índice de complicações. A mobilização precoce no pósoperatório provoca afrouxamento dos ligamentos reconstruídos, o que leva à instabilidade residual. A imobilização melhora a estabilidade, mas provoca dor e rigidez. Este trabalho tem o objetivo de avaliar se o uso do fixador externo articulado proporciona melhora na mobilidade, estabilidade e na função subjetiva de pacientes submetidos à reconstrução ligamentar. MÉTODOS: Neste ensaio clínico randomizado com grupos paralelos, 33 pacientes do ambulatório do Instituto de Ortopedia e Traumatologia do Hospital das Clínicas da Universidade de São Paulo com mais que 3 semanas de lesão dos ligamentos cruzados anterior e posterior associado à lesão de ligamento colateral fibular e/ ou ligamento colateral tibial foram submetidos à cirurgia de reconstrução multiligamentar, após alocação cega aleatória ao grupo 0 - controle (18 pacientes), com órtese rígida ou ao grupo 1 - fixador externo articulado por 6 semanas (15 pacientes), no período entre novembro de 2010 e novembro de 2013. Após seguimento mínimo de um ano de pós-operatório, a estabilidade dos ligamentos reconstruídos foi avaliada ao exame físico, foram mensurados os déficits de extensão e de flexão residual em relação ao joelho contralateral não acometido e foi aplicado o questionário específico para sintomas do joelho de Lysholm. RESULTADOS: Não houve diferença na avaliação da estabilidade articular nem na extensão entre os grupos. No grupo 1, o déficit de flexão passiva foi menor (4,8º +- 5,4º contra 18,2 +- 14,8º, p < 0,05) com mais pacientes, obtendo déficit de flexão considerado normal, de até 5º (64% contra 18%, p < 0,05) e com classificação excelente ou boa no questionário de Lysholm (73% contra 35%, p < 0,05). CONCLUSÕES: Comparado ao protocolo de reabilitação com órtese rígida removível, o uso do fixador externo articulado no tratamento cirúrgico das lesões multiligamentares do joelho proporciona os mesmos resultados de estabilidade ligamentar, aumenta a amplitude de movimento final, com manutenção da extensão e redução do déficit de flexão e proporciona melhores resultados funcionais / INTRODUCTION: Multiligament knee instability is normally caused by a trauma which results in its dislocation, an infrequent event, but one which can have devastating aftereffects. Even with the recommended surgical treatment the rate of complications is high. Early post-operative mobilization provokes loosening of the reconstructed ligaments, which leads to residual instability. Immobilization improves the stability, but causes pain and stiffness. This study aims to assess whether the use of an articulated external fixator provides improvements in the mobility, stability and the subjective function of the patients submitted to ligament reconstruction. METHODS: In this randomized clinical trial with parallel groups, 33 patients of the outpatient clinic of the Institute of Orthopaedics and Traumatology of the Hospital das Clínicas of the University of Sao Paulo with more than 3 weeks of injury to the anterior cruciate ligaments and the posterior cruciate ligaments associated with injury to the fibular collateral ligament and/or medial collateral ligament, were submitted to multiligament reconstruction surgery, after blind random allocation to either: Group 0 - control (18 patients), with rigid bracing, or to Group 1 - articulated external fixator for 6 weeks (15 patients), in the period from November, 2010 to November 2013. The stability of the reconstructed ligaments were assessed after 1 year postoperatively by physical examination, the deficit of residual extension and flexion was measured in relation to the unaffected contralateral knee and the Lysholm knee scoring scale questionnaire was applied. RESULTS: There was no difference in the assessment of joint stability or of the extension between the groups. In group 1 the passive flexion deficit was less (4.8º +- 5.4º versus 18.2 +- 14.8º, p<0.05) with more patients obtaining a flexion deficit considered normal, or up to 5º (64% versus 18%, p<0.05) and with excellent or good classification in the Lysholm knee scoring scale questionnaire (73% versus 35%, p<0.05). CONCLUSIONS: Compared to the rehabilitation protocol with removable rigid bracing, the use of an articulated external fixator in the treatment of multiligament knee injuries provides equal results for ligament stability, increases the amplitude of the Range of Motion, maintains the extension and reduces the flexion deficit, and provides better functional result
|
Page generated in 0.0438 seconds