• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 6
  • Tagged with
  • 14
  • 14
  • 14
  • 14
  • 8
  • 7
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Materialparameter und Höckerdeformation bei Restaurationsmaterialien mit unterschiedlichem Elastizitätsmodul / material parameters and cusp deflection for dental restoration materials with a variable modulus of elasticity

Schömig, Robert January 2010 (has links) (PDF)
Die Polymerisationsschrumpfung stellt bis zum heutigen Tag ein unbewältigtes Problem in der adhäsiven Restaurationstechnik dar. In vorliegenden Arbeit konnte gezeigt werden, dass die Polymerisationsschrumpfungsspannung und die Höckerauslenkung dentaler Restaurationsmaterialien nicht allein von der Polymerisationsschrumpfung abhängen. Sie werden auch vom E-Modul des Restaurationsmaterials beeinflusst. Die Verwendung von ormocerhaltigen Kompositmaterialien scheint eine empfehlenswerte Alternative zu sein, um bei niedrigen Schrumpfungswerten gleichzeitig den E-Modul und die Polymerisationsschrumpfungsspannung zu minimieren. / Purpose: to determine the influence of modulus of elasticity on cusp deflection using materials featuring different moduli but similar shrinkage Hypothesis: material with higher modulus will produce more cusp deflection during curing Conclusions: shrinkage stress and cusp deflection depend not only on shrinkage strain, but on modulus of elasticity as well use of prepolymerized fillers may reduced shrinkage strain without incrreasing modulus
12

DNA-Strangbruchinduktion, Mikrokernbildung, Zellzyklusalteration und Apoptose durch Zahnwerkstoffe in humanen Lymphozyten / DNA strand breake induction, micronuclei formation, cell cycle alteration and apoptosis through dental materials in human lymphocytes

Zinnitsch, Sabrina January 2010 (has links) (PDF)
Die Zahnwerkstoffe HEMA (Hydroxyethylmethacrylat) und TEGDMA (Triethylenglycol-dimethacrylat) gehören zu den so genannten Restmonomeren. Sie liegen nach der Polymerisation noch ungebunden vor und werden anschließend freigesetzt. Sie gelangen in den Organismus über die Pulpa, die Gingiva oder über den Speichel und können biologisch wirksam werden. Bisherige Studien zeigen dosisabhängige mutagene Effekte in tierischen und menschlichen Zellen. HEMA und TEGDMA führen zu DNA-Strangbrüchen, Mikrokernbildung, Apoptosen und nehmen Einfluss auf den Zellzyklus (G1- und G2-Verzögerung). Ebenso wurden ein allergenes Potential und eine toxische Wirkung auf die Niere beschrieben. In dieser Arbeit wurden genotoxische Effekte von HEMA und TEGDMA in humanen Lymphozyten in Konzentrationsbereichen überprüft, wie sie auch im Körper auftreten können. Hierfür wurden die Lymphozyten 24 Stunden mit 10 µM, 100 µM und 1 mM HEMA und mit 1 µM, 10 µM und 100 µM TEGDMA behandelt. Mit dem Comet Assay werden DNA-Einzel- und Doppelstrangbrüche sowie die Reparatur zuvor induzierter DNA-Schäden erfasst. Durch die Modifikation des Comet Assay mit dem Fpg-Protein werden zusätzlich oxidativ geschädigte Basen mit hoher Sensitivität nachgewiesen. Der Mikrokerntest weist manifeste DNA-Schäden auf DNA-Ebene in Form von Mikrokernen nach. Daneben lassen sich auch andere zelluläre Reaktionen wie Mitosen und Apoptosen sowie die Proliferationsrate der Zellen bestimmen. Der Chromosomen-aberrationstest dient zum Nachweis von Veränderungen in der Struktur und/oder in der Anzahl von Chromosomen eines Genoms. Mit dem Schwesterchromatidaustauschtest werden ebenfalls Chromosomenmutationen nachgewiesen. Durchflusszytometrische Methoden werden zum Nachweis von Apoptosen und zur Zellzyklusanalyse eingesetzt. Im herkömmlichen Comet Assay zeigen HEMA und TEGDMA keine signifikante Wirkung auf die DNA (OTM < 2). Es kann aber gezeigt werden, dass die Behandlung mit Fpg zu einer Verdoppelung des OTM führt. Bei 1 mM HEMA und 100 µM TEGDMA wird dadurch das OTM auf > 2 angehoben. HEMA und TEGDMA wirken sich nicht auf die Mikrokernbildung aus, jedoch wird durch den Mikrokerntest ab 1 mM HEMA und 100 µM TEGDMA eine Einflussnahme auf die Proliferation gezeigt. Die Rate früher (< 10%) und später Apoptosen Apoptosen (< 4 %) bleibt im Durchschnitt weitgehend konstant. Eine Ausnahme sind 1 mM HEMA, die die frühen Apoptosen auf > 10 % anheben. Eine Einflussnahme auf den Zellzyklus, in Form einer Verzögerung, üben 1 mM HEMA in der S-Phase und 100 µM TEGDMA in der G1-Phase aus. In den Chromosomentests werden einerseits ein dosisabhängiger Anstieg der Aberrationen und andererseits vermehrte Chromatidaustausche beobachtet. In dieser Arbeit wird die Verbindung von HEMA und TEGDMA zu oxidativen Stress im Comet Assay mit Fpg gezeigt. Da die tatsächlich in vivo erreichbaren Konzentrationen unter 100 µM liegen, ist zu schließen, dass HEMA und TEGDMA in diesem niedrigen Konzentrationsbereich keine nachteiligen Effekte ausüben, denn nur die hohen Konzentrationen (1 mM HEMA, 100 µM TEGDMA) sind in der Lage eine genotoxische Wirkung zu entfalten. Jedoch kann das Auslösen von Mutationen mit dem Chromosomenaberrationstest und Schwesterchromatidaustauschtest bestätigt werden. Um das Schädigungsprofil dieser häufig eingesetzten Zahnwerkstoffe detaillierter beschreiben zu können, müssen Untersuchungen auf Chromatidebene intensiviert werden. / The dental materials HEMA (2-hydroxyethylmethacrylate) and TEGDMA (triethylengylcol-dimethacrylate) belong to the so-called rest monomers. After the polymerisation they are still unbound and can be released afterwards. They reach the organism through the pulp, the gingiva or through the saliva and can become biological effective. Present studies indicate dose-dependent mutagene effects in animal and human cells. HEMA and TEGDMA induce DNA strand breaks, micronuclei formation, apoptosis and have influence on the cell cycle (G1 and G2 delay). Also an allergic potential and a toxic effect on kidneys were described. In this study genotoxic effects were checked by HEMA and TEGDMA in human lymphocytes in concentration areas as they can also appear in the body. The lymphocytes were treated 24 hours with 10 µM, 100 µM and 1 mM HEMA and with 1 µM, 10 µM and 100 µM TEGDMA. With the comet assay DNA single and double strand breaks as well as the repair before induced DNA damage are grasped. By the modification of the comet assay with the Fpg protein oxidative injured bases are proved in addition with high sensitivity. The micronucleus test proves manifest DNA damages at DNA level in the form of micronuclei. Beside other cellular reactions like mitosis and apoptosis as well as the proliferation of the cell can also be determined. The chromosomal aberration test serves for the proof of changes in the structure and/or in the number of chromosomes of a genome. With the sister chromatid exchange test chromosomal mutations are also proved. Flow cytometric methods are used to the proof by apoptosis and to the cell cycle analysis. In the conventional comet assay HEMA and TEGDMA indicate no significant effect at the DNA (OTM < 2). However, it can be shown that the treatment with Fpg leads to a duplication of the OTM. At 1 mM HEMA and 100 µM TEGDMA the OTM is thereby raised on >2. HEMA and TEGDMA do not affect the induction of micronuclei, however the micronucleus test indicate a intervention on the proliferation from 1 mM HEMA and 100 µM TEGDMA. The rate earlier (< 10 %) and late apoptosis (< 4 %) remains widely steady on average. An exception is 1 mM HEMA which raise the early apoptosis on > 10 %. 1mM HEMA have an influence on the cell cycle, in form of a delay, in the S phase and 100 µM TEGDMA in the G1 phase. In the chromosomal tests are observed dose-dependent increase of the aberrations on the one hand and increased chromatid exchanges on the other hand. In this study the connection is shown by HEMA and TEGDMA to oxidative stress in the comet assay with Fpg. Because the really in vivo available concentration lie under 100 µM, is to be closed that HEMA and TEGDMA exert no disadvantageous effects in this low concentration area, because only the high concentrations (1 mM HEMA and 100 µM TEGDMA) are able to unfold a genotoxic effect. However, the release of mutations can be confirmed by the chromosomal aberration test and the sister chromatid exchange test. To be able to describe the damage profile of these often used dental materials more detailed investigations on chromatid level must be intensified.
13

Neuartige ORMOCER®-basierte Materialsysteme und deren Formgebung mittels Digital Light Processing für hochwertige dentale Versorgungen / Novel ORMOCER®-based material systems and their shaping by means of Digital Light Processing for high-quality dental restorations

Kolb, Carina January 2022 (has links) (PDF)
Im Rahmen der vorliegenden Dissertation wurden ORMOCER®-basierte Materialsysteme für dentale Versorgungen entwickelt, die additiv mittels Digital Light Processing (DLP) verarbeitbar sind und ein hochwertiges, auf die vorgesehene Zielanwendung abgestimmtes Eigenschaftsprofil besitzen. Zunächst wurden grundlegende Untersuchungen zum DLP-Druck des Harzsystems und einfachen Kompositen durchgeführt, um auftretende Herausforderungen zu identifizieren und die weitere Vorgehensweise festzulegen. Ausgehend davon konzentrierte sich die Arbeit neben der Vermeidung der klebrigen Sauerstoffinhibierungsschicht auf der Bauteiloberfläche einerseits darauf, die Maßhaltigkeit bei DLP-gedruckten Bauteilen mit überhängenden Strukturen zu steigern. Insbesondere wurde das Augenmerk hier auf die Verwendung von organischen Lichtabsorbern zur Realisierung von hochtransluzenten Harz-basierten Bauteilen gelegt. Andererseits lag ein weiterer Schwerpunkt der Arbeit auf der Entwicklung von DLP-druckbaren Kompositen mit hoher Transluzenz. Die dafür nötige Brechzahlanpassung von Harzsystem und Füllstoff wurde zum einen durch die Synthese neuer, höherbrechender Harzsysteme und zum anderen durch die Verwendung hochbrechender ZrO2-Nanopartikel realisiert. Die resultierenden hochtransluzenten Komposite wurden umfassend mechanisch charakterisiert sowie erfolgreich DLP-gedruckt. / In this work, ORMOCER®-based material systems for dental restorations were developed which can be additively processed by digital light processing (DLP) and have a high-quality property profile tailored to the intended target application. Initially, basic investigations were carried out on the DLP printing of the resin system and simple composites in order to identify any challenges that arose and to determine the further course of action. Based on this, in addition to avoiding the sticky oxygen inhibition layer on the part surface, the work focused on the one hand on increasing the dimensional accuracy of DLP-printed parts with overhanging structures. In particular, attention was paid here to the use of organic light absorbers to realize highly translucent resin-based parts. On the other hand, another focus of the work was on the development of DLP printable composites with high translucency. The necessary refractive index adaption of resin system and filler was realized on the one hand by synthesizing new, higher refractive index resin systems and on the other hand by using highly refractive ZrO2 nanoparticles. The resulting highly translucent composites were extensively characterized mechanically and successfully DLP-printed.
14

Der Einfluss von Kavitätenvolumen, Polymerisationsschrumpfung und Schichttechnik auf die Randschlussqualität von Klasse-II-Kompositfüllungen / The influence of cavity depth, polymerization shrinkage and application technique on marginal seal and margin fidelity of class II resin-based composite restorations

Zentgraf, Christian January 2008 (has links) (PDF)
Die Randspaltbildung adhäsiver Restaurationen stellt bis heute ein grundlegendes Problem dar. Ziel dieser Untersuchung war die In-vitro-Evaluation der Randadaptation von Klasse-II-Kompositfüllungen nach künstlicher Alterung in Abhängigkeit von Kavitätentiefe, Komposit und Schichttechnik. Zu diesem Zweck wurden an 48 extrahierten Weisheitszähnen mittels sonoabrasiven Präparationsinstrumenten zwei unterschiedlich standardisierte Klasse-II-Kavitäten (flache Kavität bzw. tiefe Kavität) hergestellt. Diese wurden mit Hilfe zweier Schichttechniken (Drei-Schicht-Technik bzw. Schalentechnik) und zweier Komposite (Hybridkomposit (Tetric Ceram, Ivoclar) bzw. Nano-Hybridkomposit (Grandio, Voco)) gefüllt. Nach künstlicher Alterung mittels Thermocycling und Wasserlagerung wurden die Proben zur Beurteilung der Randadaptation mittels Farbstoffpenetration und unter dem Rasterelektronenmikroskop qualitativ und quantitativ bewertet. Die Ergebnisse wurden mittels dreifaktorieller Varianzanalyse auf statistische Signifikanz untersucht. Ein Einfluss des Kavitätenvolumens auf die Randadaptation konnte in dieser Studie nicht eindeutig nachgewiesen werden. Es zeigte sich jedoch am vertikalen Rand eine signifikant schlechtere Randadaptation aufgrund der häufigeren Ausbildung eines Spalts bei großem Kavitätenvolumen. Bezüglich der Schichttechnik konnte ein Einfluss auf die Randqualität gezeigt werden: Bei beiden Auswertungsmethoden war die Schalentechnik signifikant gegenüber der Drei-Schicht-Technik überlegen. Ebenfalls konnte ein Einfluss des Komposits auf die Randadaptation nachgewiesen werden: Keines der beiden getesteten Komposite war generell überlegen; es zeigte sich vielmehr eine signifikante Abhängigkeit von Komposit und Schichttechnik. Das Hybridkomposit zeigte gegenüber dem Nano-Hybridkomposit bessere Randqualitäten bei den mit Hilfe der Schalentechnik gefüllten Kavitäten. Bei den mittels Drei-Schicht-Technik gefüllten Kavitäten schnitt hingegen das Nano-Hybridkomposit besser ab. Dies ist wahrscheinlich darauf zurückzuführen, dass das Hybridkomposit seine Fähigkeit zum Nachfließen während der Polymerisation, welche auf sein geringes E-Moduls zurückzuführen ist, in Schichten mit kleinem C-Faktor ausnutzen und so seine größere Volumenschrumpfung ausgleichen kann. Schichtungen mit großem C-Faktor verringern die Möglichkeit des Nachfließens und das Nano-Hybridkomposit zeigt dort bessere Randadaptation aufgrund seiner niedrigeren Volumenschrumpfung. Diese Studie konnte zeigen, dass sowohl Materialeigenschaften wie Volumenschrumpfung und E-Modul als auch der C-Faktor - und damit verbunden die Füllungstechnik - entscheidenden Einfluss auf die Randadaptation von in vitro gelegten Füllungen in standardisierten Klasse-II-Kavitäten haben. Die Studie stellte heraus, dass diese drei Faktoren (Volumenschrumpfung, E-Modul und C-Faktor) nicht getrennt voneinander betrachtet werden sollten. Es zeigte sich, dass für Klasse-II-Kavitäten die Schalentechnik signifikant überlegen in Bezug auf die Randschlussqualität ist; dies gilt insbesondere für das Hybridkomposit „Tetric Ceram“. / Objectives: To evaluate the influence of cavity depth, polymerization shrinkage and application technique on marginal seal and margin fidelity of class II resin-based composite restorations. Methods: Standardized MOD class II cavities were prepared in extracted human molars. Occlusal boxes were 3.5mm wide and either 3mm or 4.5mm deep. Standardized interproximal boxes (box size: 3.5x4.5mm, bevel size 5.5x5.5mm) were prepared using sonic shape preparation instruments (SonicSys Approx Size 3) and reciprocating files (Bevelshape B15C). After application of a 3-step etch&rinse adhesive (Optibond FL), the cavities were restored using a resin-based composite of high (Tetric Ceram, 2.8%) or low polymerization shrinkage (Grandio, 1.6%). Interproximal boxes were restored using either a centripetal or a horizontal layering technique. After water storage (30 days, 37°C) and thermocycling (2500x 5-55°C), margin quality was evaluated in the SEM using the replica technique. Marginal seal was studied using dye penetration (AgNO3 50%, 2h, 37°C). For each combination of parameters six specimens were prepared. Results were analyzed using 3-way ANOVA. Results:The centripetal layering technique produced less dye penetration (P<0.01) and margin gaps (P<0.001) than the horizontal layering technique. This difference was more pronounced for the high shrinkage composite (interaction: P<0.05 / P<0.001).

Page generated in 0.0846 seconds