• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 47
  • 29
  • 11
  • Tagged with
  • 87
  • 60
  • 32
  • 31
  • 25
  • 25
  • 25
  • 22
  • 18
  • 16
  • 16
  • 15
  • 11
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Die Entwicklung der zahnärztlichen Ausbildung in der Türkei bis zur Gründung der ersten zahnmedizinischen Fakultät (1827-1964) /

Ülger, Gonca. January 2004 (has links)
Zugl.: Köln, Universiẗat, Diss., 2004.
2

Odontologie im numismatischen Spiegel ein Beitrag zur Geschichte der Zahnheilkunde /

Heckert, Gerold Rüdiger. January 2006 (has links)
Universiẗat, Diss., 2006--Giessen.
3

Materialparameter und Höckerdeformation bei Restaurationsmaterialien mit unterschiedlichem Elastizitätsmodul / material parameters and cusp deflection for dental restoration materials with a variable modulus of elasticity

Schömig, Robert January 2010 (has links) (PDF)
Die Polymerisationsschrumpfung stellt bis zum heutigen Tag ein unbewältigtes Problem in der adhäsiven Restaurationstechnik dar. In vorliegenden Arbeit konnte gezeigt werden, dass die Polymerisationsschrumpfungsspannung und die Höckerauslenkung dentaler Restaurationsmaterialien nicht allein von der Polymerisationsschrumpfung abhängen. Sie werden auch vom E-Modul des Restaurationsmaterials beeinflusst. Die Verwendung von ormocerhaltigen Kompositmaterialien scheint eine empfehlenswerte Alternative zu sein, um bei niedrigen Schrumpfungswerten gleichzeitig den E-Modul und die Polymerisationsschrumpfungsspannung zu minimieren. / Purpose: to determine the influence of modulus of elasticity on cusp deflection using materials featuring different moduli but similar shrinkage Hypothesis: material with higher modulus will produce more cusp deflection during curing Conclusions: shrinkage stress and cusp deflection depend not only on shrinkage strain, but on modulus of elasticity as well use of prepolymerized fillers may reduced shrinkage strain without incrreasing modulus
4

Abrasions- und Adhäsiv-Verhalten fließfähiger Komposite im Rahmen der kieferorthopädischen Langzeitretention / Wear and shear bond strength of flowable composites with regard to the long-term retention in orthodontics

Heinemann, Elena January 2013 (has links) (PDF)
In dieser Arbeit wurden acht fließfähige Komposite auf das Abrasions und Abscherverhalten von fließfähigen Kompositen untersucht. Die Materialien Filtek Supreme XT, Transbond LR, Transbond Supreme LV, Tetric EvoFlow, Venus Diamond Flow, Vertise Flow, Gradia Direct LoFlo sind im ersten Teil auf Volumenverlust und Tiefenverlust sowohl nach 150.000 als auch nach 300.000 Zyklen getestet worden. Durch die Drei-Medien-Abrasion wurden die fließfähigen Komposite von einem Mohn-Wasser-Gemisch abradiert. Filtek Supreme XT, Transbond LR und Transbond Supreme LV erwiesen sich als besonders abrasionsstabil in Hinblick auf die Langzeitretenion im Mund. In dem zweiten Teil wurden diese acht Materialien auf die Abscherwiderstände untersucht. Es sollte der Einfluss von Temperaturwechseln im Sinne einer künstlichen Alterung geklärt werden und ob eine Zwischenschicht aus niederviskösem Komposit (Adhäsiv) bei fließfähigen Kompositen notwendig ist. Nach Durchführung des Versuches und Auswertung der Ergebnisse erreichten die Komposite mit einem geringeren Füllstoffanteil ohne Adhäsiv ebenso gute Werte wie mit Adhäsiv. Dagegen erzielten Komposite mit hohem Füllstoffanteil und geringer Viskosität, höhere Haftwerte mit Adhäsiv als Zwischenschicht. Besonders das Material Transbond LR bestätigt diese Aussage und erreicht als hochgefülltes Komposit mit einer Zwischenschicht aus Adhäsiv Spitzenwerte von 27,5MPa. / In this study eight flowable composites were tested in wear and shear-bond strength. The materials Filtek Supreme XT, Transbond LR, Transbond Supreme LV, Tetric EvoFlow, Venus Diamond Flow, Vertise Flow, Gradia Direct LoFlo were examined for loss of volume and loss of depth after 150.000 and 300.000 cycles. By the three-body-wear the flowable composites were worn by a poppy-water mixture. Filtek Supreme XT, Transbond LR and Transbond Supreme LV proved particularly resistant to abrasion with regard to the long-term retention in the mouth. In the second part, these eight materials were examined for shear bond strength. The influence of temperature changes as artificial aging has to be clarified and whether an intermediate layer of low viscous composite (adhesive) is required for flowable composites. After carrying out the test and evaluation of the results, the composites with lower filler content proved the same good results as without adhesive. In contrast, composites with high filler content and low viscosity, showed a higher bonding strength with adhesive as an intermediate layer. Particularly the material Transbond LR confirms this statement, and reaches as high-filled composite with an intermediate layer of adhesive peak values of 27.5 MPa.
5

Magnetresonanztomographie in der Zahnheilkunde - hochauflösende zahnmedizinische Anwendungen in der MRT mit einer Entwicklung zur Bewegungskorrektur / Magnetic Resonance Imaging in Dentistry – high-resolution dental applications in MRI with development of a method for motion correction

Hopfgartner, Andreas January 2015 (has links) (PDF)
Die zahnmedizinische Behandlung von Erkrankungen der Zähne oder im Bereich der Mundhöhle erfolgt bei Weitem nicht immer aus optischen Gründen. Diese Erkrankungen werden auch mit ernsthaften Erkrankungen in Zusammenhang gebracht. Studien haben gezeigt, dass einige Erkrankungen im Mund- und Zahnbereich zu Herz- und Lungenkrankheiten oder Diabetes führen können. Oftmals erstreckt sich die Pathologie oder Symptomatik von Mund- und Zahnerkrankungen über einen weiten Bereich. In der zahnmedizinischen Klinik kommen daher viele verschiedene diagnostische Apparate zum Einsatz. Allerdings zählt die Magnetresonanztomographie, die sich in anderen Bereichen bereits zum wichtigsten bildgebenden Diagnosetool entwickelt hat, dort noch nicht zu den Standardverfahren. Dabei liegen ihre Vorteile auf der Hand: sie ist bekannt für sehr gute Bildkontraste vor allem zwischen verschiedenen Weichgewebsarten und kommt ohne gefährliche ionisierende Strahlung aus. Wahrscheinlich ist ersteres der Grund, warum die MRT in der Zahnmedizin noch nicht sonderlich vertreten ist, kommt es dort oft auf die kontrastreiche Darstellung von Hartgeweben an. Neueste Entwicklungen und Studien belegen jedoch die vielseitigen Vorteile der MRT auch in diesem Bereich. Ziel dieser Arbeit von der applikativen Seite betrachtet, war es, das enorme Potential der MRT in den vielseitigen Bereichen der Zahnmedizin weiterhin aufzuzeigen. Viele dieser Anwendungen stellen jedoch sehr hohe Anforderungen an die Systeme. Meist sind die darzustellenden Strukturen sehr klein und erfordern eine hohe Auflösung. Während man beim Röntgenverfahren beispielsweise die Energie des Strahles (Dosis) steigern kann, bedeutet dies in der MRT (ohne das Gerät zu wechseln) eine Verlängerung der Messzeit. Gerade im Bereich des Kopfes kommt es oft zu ungewollten Bewegungen, die das Ergebnis und die Reproduzierbarkeit der gewonnenen diagnostischen Informationen verschlechtern oder gänzlich unbrauchbar machen. Die grösste Herausforderung dabei ist die dreidimensionale Abformung von Zahnoberflächen in der Prothetik. Dieses Verfahren kann eine aufwändige und unangenehme manuelle Abformung der Zähne und die Herstellung eines Zwischengipsmodells ersetzen und ein direktes dreidimensionales Modell der Zahnoberflächen produzieren. Durch die moderne CAD-/CAM-Technik kann daraus vom Zahntechniker direkt eine Zahnrestauration erstellt werden. Daher war ein wichtiger Bestandteil des Projekts dentale MRT die Entwicklung einer Methode zur Erkennung und gleichzeitiger Korrektur von Bewegungen. Verschiedenste Anforderungen waren an die Methode gestellt. Zum einen muss die Methode bereits Bewegungen im Bereich von ~100 µm erkennen, um die Anforderungen an die finale Bildauflösung zu unterschreiten. Bei der dentalen Abformung wird eine 1-Kanal-Empfängerspule verwendet und je nach Messung kann der Patient dabei auf dem Bauch oder Rücken liegen. Weiterhin muss die Bewegungserkennung ohne zusätzliche externe Geräte wie Kameras, deren Sicht z.B. durch den Patienten verdeckt ist, durchführbar sein. Die vorliegende Arbeit deckt also zwei größere Themenblöcke ab. Zum einen wurden in der Arbeit neue Applikationen entwickelt oder weiterentwickelt, um verschiedenen Bereichen der Zahnmedizin den Zugang zu MRTUntersuchungen zu eröffnen. Kapitel 4 beschreibt die Möglichkeit, die Bewegung des Kiefergelenks dynamisch zu erfassen. Es stellte sich in der Arbeit heraus, dass sowohl die Bewegung von Weichgewebeanteilen darstellbar waren, als auch der intraartikuläre Abstand im Kiefergelenk unter Kaubelastung in Echtzeit vermessen werden konnte. Dabei wurde die Bildgebungssequenz und der zugehörige Rekonstruktionsalgorithmus so entwickelt, dass die Daten flexibel und ohne Vorwissen akquiriert und aufbereitet werden können. Hierbei konnten verschiedenen Pathologien anhand der dynamischen Bilder sichtbar gemacht werden und die dynamische MRT konnte Erkrankungen erkennen, die mit anderen Mitteln nicht sichtbar waren. Die vielen diagnostischen Möglichkeiten, die dadurch entstehen sind bisher noch nicht untersucht und sollten durch großangelegte Studien untersucht und belegt werden. Kapitel 5 beschreibt die Ergebnisse einer großangelegten Studie im Bereich der dentomaxillären Bildgebung . Die diagnostischen Möglichkeiten der MRT für die kieferorthopädische Anwendung liegen klar auf der Hand. Die typischen Patienten in der Kieferorthopädie sind Kinder und Jugendliche. Die Abwesenheit von gewebsschädigender Strahlung ist hier ein besonderer Vorteil der MRT. Eine Messung dauert zudem nach diversen Weiterentwicklungen der Methode nur noch 2 (bzw. 4) Minuten. Die Auflösung in den gerenderten Bildern beträgt 0.25x0.25x0.5 mm. Mit der Methode konnte unter anderem die Geminisierung einer Zahnwurzel und der Abstand des Zahnmarks zur Zahnoberfläche (Zahnschmelz) dargestellt und vermessen werden. Kapitel 6 stellt Neuentwicklungen im Bereich der dentalen Abformung von Zahnoberflächen dar. Hier wurde eine neue Methode entwickelt um den Patientenkomfort bei der Messung zu steigern und so Bewegungen im Vorhinein zu unterbinden. Bei der alten Methode liegt der Patient auf dem Bauch und ein großer Teil der Mundhöhle ist mit Kontrastmittel befüllt. Durch die Verwendung einer präparierten Tiefziehschiene kann das Kontrastmittel nun lokal appliziert werden und eine Messung in Rückenlage das Patienten ist somit problemlos möglich. Die damit verbundene Reproduzierbarkeit der Abformungsergebnisse wäre durch eine großangelegte Studie zu zeigen. Die Hauptaufgabe der vorliegenden Dissertation war es, eine Methode zur Bewegungskorrektur zu entwickeln, die es ohne eine große Anzahl an Zusatzgeräten ermöglicht, die Bewegung eines Subjekts während der Messung zu erfassen und dementsprechend zu korrigieren. Diese neue Methode, gestützt auf einer Messung eines MRT-aktiven Markers der am Subjekt angebracht wird, beruht außer der Verwendung des Markers nur auf MRT-Hardware. Die Methode wird in Kapitel 8 vorgestellt. Da es sich bei der Methode um eine Neuentwicklung handelt, war es in erster Linie wichtig, die Einflüsse der verschiedenen Parameter, die sich auf die Positionierungsgenauigkeit auswirken, abzuschätzen und letzten Endes festzulegen. Dies wurde in mehreren Vorstudien, Experimenten und Computersimulationen abgehandelt. In der Arbeit konnte durch Validierungsexperimente gezeigt werden dass sich mit dem bildbasierten Navigator Bewegungen im Genauigkeitsbereich von ~50 µm (Translation) und ~0.13◦(Rotation) detektieren lassen. Mit den Positionsinformationen lassen sich MRT-Daten retrospektiv korrigieren oder idealerweise das Bildgebungsvolumen in Echtzeit anpassen um Inkonsistenzen in den Daten im Vorhinein vorzubeugen. Durch Bewegung beeinträchtigte in-vivo Daten konnten so mit der Methode korrigiert werden und anhand eines geeigneten Phantoms konnte die Verbesserung der Erkennung von Kanten, wie sie beispielsweise bei der dentalen Abformung angewandt wird, gezeigt werden. Die kontinuierlichen Entwicklungen in den Bereichen Hard-, Software und Algorithmik ermöglichen weitere hochauflösende Anwendungen. In Kapitel 9 sind die Ergebnisse einer Studie gezeigt, die sich mit der Analyse der Handbewegungen während einer Messung beschäftigt. Für eine hochauflösenden Darstellung der Handanatomie bei 7 T ist eine Unterbindung der Handbewegung sehr wichtig. Um ein geeignetes Design für eine Empfängerspule zu entwerfen, die Bewegungen der Hand unterbindet, wurde eine qualitative Bewegungsanalyse der Hand in mehreren verschiedenen Positionen durchgeführt. Durch Vergleich der Ergebnisse konnte so auf geeignete Designs zurückgeschlossen werden. / The treatment of the teeth or diseased of the oral cavity is by far not only administered for aesthetic reasons. These diseases are sometimes also associated with other serious diseases. Studies have shown that some diseases of the mouth, the gingiva or the surrounding area can lead to heart and lung disease or diabetes. Oftentimes the pathology or symptomatology of dental or oral diseases extends to a wide area. In the dental clinic many different diagnostic devices are used. However, magnetic resonance imaging, which has developed in other areas as the most important diagnostic imaging tool, is not frequently used in dentistry to the present day, although their advantages are obvious: it is known for excellent image contrast, mainly between different soft tissues and comes without hazardous ionizing radiation. The former is probably the reason why the MRI is not yet a standard method in dentistry: here in most cases the contrast of hard tissues is of relevance. However, recent developments and studies demonstrated the versatile advantages of MRI in this area. The aim of this work as seen from the perspective of application, was to continuously show the enormous potential of MRI in the diverse areas of dentistry. However, many of these applications put very high requirements on the systems. Usually structures to display are very small and require very high resolution. To improve the resolution while using the X-ray method, e.g., one can increase the beam energy (dose). In MRI (without changing the MRT scanner) this results in an extension of measurement time. Especially in the area of the head this oftentimes leads to unwanted movements during the measurement time that worsen the outcome and reproducibility of the obtained diagnostic information or making it completely useless. The biggest challenge is the measurement of a three-dimensional impression of the tooth surfaces in prosthetics. This process can replace a complex and unpleasant manual impression of the teeth and avoid the production of an intermediate plaster model. Using MRT techniques, a direct three- dimensional model of the tooth surfaces can be produced. By modern CAD/CAM technology, a dental restoration can be directly manufactured by the dental technician using the digital 3D model. Therefore, an important task of the project was the development of a dental MRT method for the detection and correction of movements. Various requirements were imposed on the method. Firstly, the method must be able to detect movements in the range of ~100 µm to fall below the requirements of the final image resolution. For the acquisition of the contrast agent’s signal, a 1-channel receiver coil is used and depending on the measurement, the patient can lie prone or supine. Furthermore, the motion detection system must work without extensive external devices such as cameras, whose direct vision may be obscured by the patient, e.g. This thesis covers two major subject areas. Firstly, new applications and methods have been developed and further developed in order to provide the various fields of dentistry access to MRT techniques. Chapter 4 describes the possibility to image the motion of the temporomandibular joint dynamically in real-time. In this work it turned out that both, the movement of the soft tissue components were represented, as well as the intra-articular distance in the TMJ could be measured during mastication (under load) in real-time. Here, the imaging sequence and the corresponding reconstruction algorithm were designed such that the data can be acquired without a prioiri knowledge and processed flexibly. MRT showed different pathologies in the images and dynamic MRT could detect some diseases that could not be diagnosed by other means. The emerging diagnostic possibilities should be investigated and the results verified by large-scale studies. Chapter 5 describes the results of dento-maxillary MRT imaging, supported by a large-scale study. The diagnostic capabilities of MRI for orthodontic applications are obvious. The typical patient in orthodontics are children and adolescents. The absence of tissue-damaging radiation is a particular advantage of MRI here. After various developments, the acquisition time of a measurement lasted depending on the method only 2 (4) minutes. The resolution in the rendered images was 0.25x0.25x0.50 mm3. Using the proposed method, among other things a geminisation of a tooth root could be shown and the distance of the dental pulp to the tooth surface (enamel) measured. Chapter 6 presents new developments in the field of digital impressions of tooth surfaces. Here, a new method was developed in order to increase patient comfort during the measurement. This approach helps to prevent movements of the subject in advance. With the old method, the patient lies prone and a large part of the oral cavity is filled with contrast agent. By using a prepared dental cast, the contrast agent can be applied locally and hence the patient may lay supine during the measurement. The associated reproducibility of dental impressions should be shown through a large-scale study. The main task of this thesis was to develop a method for motion correction that allows to detect the movement of a subject during the measurement without a large number of additional devices and correct the acquired data accordingly. This new navigator method, based on the measurement of a MRT-active marker attached to the subject, makes use of MRT hardware only, except for the additional marker. The method is described in chapter 8. Since this is a new development, it was important to primarily estimate the effects of the various parameters and their impact on the positioning accuracy. This has been evaluated in several preliminary studies, experiments and computer simulations. By validation experiments it was shown in the studies that the image-based navigator detects movements with an accuracy of ~50 µm(translation) and ~0.13◦ (rotation). With the position information obtained from the navigator, the MRT data can be corrected retrospectively or the volume of interest can be adjusted in real-time during the imaging process to prevent inconsistencies in the data in advance. In-vivo MRT data impaired by motion of a subject during the measurement could be corrected using the MoCoLoCo method. By using an appropriate phantom and simulation a movement, it could be shown that using the proposed method, the quality of edge detection (as used in dental impressions, e.g.) could be restored. Various new high-resolution applications emerged due to the continuous development in hardware, software and algorithms. In chapter 9, the results of a study are presented, which deals with the analysis of shivering movements of the hand during a measurement. For a high-resolution depiction of hand anatomy at 7 T, a suppression of the hand movement is very important. In order to develop an optimal design for a hand receiver coil, a qualitative analysis of the hand movement in several different positions was performed. By comparison of the results, a suitable coil design could be developed.
6

Verbundfestigkeiten von Keramikveneers auf mit Compositefüllungen vorbehandelten Zähnen /

Bock, Melanie. January 2004 (has links)
Universiẗat, FB Medizin, Diss.--Hamburg, 2004.
7

Magnetic resonance imaging in dental medicine

Tymofiyeva, Olga January 2010 (has links)
Zugl.: Würzburg, Univ., Diss., 2010
8

Thermische Analyse : Möglichkeiten zur Untersuchung von dentalen Kunststoffen

Schießl, Cornelia January 2008 (has links)
Regensburg, Univ., Diss., 2008.
9

Randdichtheit und Randqualität von Kl. II-Füllungen aus einem Siloran bzw. methacrylatbasierten Kompositen unter Verwendung eines selbstkonditionierenden Dentinhaftvermittlers bei vorheriger Schmelz- und Dentinätzung in vitro / Micro-leakage and marginal integrity of class II restorations using a silorane compared to methacrylate-based resin composites luted with self-etch adhesives after phosphoric acid etching of enamel and dentine in vitro

Häfner [geb. Wagner], Daniela Claudia January 2017 (has links) (PDF)
Im Rahmen dieser In-vitro-Studie wurde Randdichtheit und Randqualität von plastischen Füllungsmaterialien aus einem schrumpfungsreduziertem Siloran (FiltekTM Silorane), zwei Hybridkompositen (Tetric EvoCeram® und ClearfilTM AP-X) und einem Nanokomposit (FiltekTM Supreme XT) mit den dazugehörigen Dentinadhäsivsystemen in Klasse II-Kavitäten mit einem von Schmelz und einem von Dentin begrenzten Füllungsrand untersucht. Obwohl die Hersteller die Dentinhaftvermittlermaterialien als selbstkonditionierend im Schmelz und Dentin vermarkten, wurde ein Total-Etching durchgeführt. Dessen Auswirkungen auf die Systeme sollte im Vergleich zu den früheren Arbeiten mit selektiver Schmelzätzung bzw. Selbstkonditionierung nach Herstellerangabe untersucht werden. An 80 extrahierenten dentes sapientes wurden Klasse II-Kavitäten nach Black präpariert, die eine Ausdehnung von 3,5 mm in vestibulo-oraler Richtung und eine okklusale Tiefe von 4 mm besaßen. Mesial wurde die okklusale Tiefe von 4 mm beibehalten, distal endete die Kavität an der Schmelz-Zement-Grenze. Die approximalen Schmelzränder wurden auf einer Breite von 1 mm angeschrägt. Die okklusal-zervikale Ausdehnung variierte je nach Ausdehnung der klinischen Krone zwischen 5 und 7 mm. In Inkrementtechnik wurden die Füllungen gelegt und ausgearbeitet. Die Materialien wurden wie folgt kombiniert: Silorane System Adhesive / FiltekTM Supreme XT / FiltekTM Silorane, Silorane System Adhesive / FiltekTM Silorane, AdperTM ScotchbondTM SE / FiltekTM Supreme XT Flow / FiltekTM Supreme XT Universalrestaurationsmaterial, AdperTM ScotchbondTM SE / FiltekTM Supreme XT Universalrestaurationsmaterial, ClearfilTM SE Bond / ClearfilTM AP-X, Clear-filTM SE Bond / Clearfil MajestyTM Flow / ClearfilTM AP-X, AdheSE® Bond / Tetric EvoFlow® / Tetric EvoCeram®, AdheSE® Bond / Tetric EvoCeram®. Nach 15-tägiger Lagerung in 0,9 %-iger Kochsalzlösung bei 37°C wurden die Proben einer Temperaturwechselbelastung (2500 Zyklen bei 5°C und 55°C, Verweilzeit 30 s) unterzogen. Im Anschluss an das Thermocycling erfolgte eine weitere 15-tägige Lagerung in Kochsalzlösung bei 37°C. Nach Herstellung von Replika zur Untersuchung der Randqualität unter dem Elektronenmikroskop wurde ein Farbstoffpenetrationstest zur qualitativen Randanalyse durchgeführt. Hierzu wurden die Zähne in 50 Gewichts-% AgNO3-Lösung eingelegt, belichtet und in zwei Ebenen (mesial-distal und bukkal-lingual) geschnitten. Die Auswertung erfolgt mit einem Auflichtmikroskop. Die statistische Auswertung erfolgte mit nicht-parametrischen Testverfahren wie dem Wilcoxon-Vorzeichen-Rang-Test und dem Kruskal-Wallis-Test. Unter-schiede zwischen den einzelnen Versuchsgruppen wurden mit dem multiplen Mittelwertsvergleich nach Nemenyi ermittelt. Das Signifikanzniveau war p<0,05. Filtek™ Silorane ist den anderen Kompositen nicht überlegen. Unabhängig vom verwendeten Material hat die Lage des Füllungsrandes im Zahn entscheidenden Einfluss auf die Randdichtheit und Randqualität bei Klas-se II-Füllungen. Die Anzahl der Randspalten und die Farbstoffpenetration sind okklusal am geringsten (im Mittel 2%), dafür aber der prozentuale Anteil der Überschüsse am größten (im Mittel 36%). Randdichtheit und Randqualität sind im Schmelz besser als im Dentin. Weder unter dem Elektronenmikroskop, noch unter dem Auflichtmikroskop, konnte ein Unterschied von statistischer Signifikanz zwischen der Verwendung und der Nichtverwendung eines Flowables zur Verbesserung der marginalen Integrität aufgezeigt werden. Das Hybridkomposit Tetric EvoCeram® schnitt beim Farbstoffpenetrationstest und der rasterelektronenmikroskopischen Untersuchung schlechter ab als das Filtek™ Silorane sowie als das Universalhybrid- und Nanokomposit. / Aim of this study was to analyse the micro-leakage and marginal integrity of class II restorations using a silorane compared to methacrylate-based resin composites luted with self-etch adhesives after phosporic acid etching of enamel and dentine in vitro. Eighty extracted human molars were used, divided into eight groups at ten molars. After preparing mod cavities, the teeth were filled with: Silorane Systeme Adhesive and FiltekTM Silorane, AdperTM ScotchbondTM SE and FiltekTM Supreme XT, ClearfilTM SE Bond and ClearfilTM AP-X, AdheSE® Bond and Tetric EvoCeram®. In four groups, an additional flowable was used. After artificial aging, a quantitative margin analysis was performed by means of a scanning electron microscope (SEM). After storage in AgNO3 solution, dye penetration was examinated under a stereomicroscope. Results: FiltekTM Silorane is not better than the other composites. Tetric EvoCeram® showed the highest values of dye penetration. No statistically significant difference was observed between groups filled with the same composite with and without an additional flowable composite. The location of the restorative junction in the tooth strongly influence the marginal integrity and quality.
10

Entwicklung eines Materialmodells für zahnärztliche Füllungen auf Kompositbasis /

Koplin, Christof. January 2008 (has links)
Universiẗat, Diss.--Karlsruhe, 2007.

Page generated in 0.0597 seconds