• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1196
  • 278
  • 187
  • 183
  • 153
  • 65
  • 62
  • 47
  • 31
  • 23
  • 14
  • 12
  • 9
  • 5
  • 4
  • Tagged with
  • 2858
  • 578
  • 475
  • 300
  • 298
  • 290
  • 265
  • 251
  • 220
  • 211
  • 207
  • 179
  • 163
  • 147
  • 142
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
461

Estudo dos fenômenos que ocasionam quebras do arame Cultura Aérea derivados do aço SAE 1057B trefilado e galvanizado

Krug, Felipe January 2013 (has links)
Na busca contínua de atender as exigências de um mercado cada vez mais competitivo, as empresas devem buscar diminuir todas as suas perdas em seus processos produtivos, reduzindo custos e ganhando margem em seus produtos. Este trabalho teve como objetivo investigar os fenômenos presentes na ocorrência de quebras dos produtos derivados do aço SAE 1057B trefilado e galvanizado utilizado em culturas aéreas. O estudo utilizou bibliografia documental, pesquisa de laboratório e uma amostra composta por trinta e seis relatórios de análises sobre o desempenho do produto intermediário trefilado, ou do produto final galvanizado. Os dados referem-se à eventos de falhas do produto em quaisquer etapas do processo produtivo e mesmo de aplicação em campo. Juntamente com ensaios efetuados especificamente para amparar as conclusões destes relatórios, efetuou-se pesquisa bibliográfica para dar suporte às conclusões. Identificaram-se similaridades entre estudos de alguns autores e análises amostrais de testes padronizados de tração e enrolamento sobre o próprio eixo de outubro 2010 a setembro de 2011. Os resultados mostraram que o fenômeno que induz a um elevado índice de quebra do arame Cultura Aérea é o envelhecimento que ocorre posteriormente à sua passagem por elevadas reduções percentuais de área no processo de trefilação, que encrua o material, e em função de elevadas temperaturas encontradas no processo de galvanização, tendo, ainda, suas consequências amplificadas por pontos de concentração de tensões. Algumas soluções para amenizar a ocorrência do envelhecimento foram propostas, como o aumento do número de passes, o que reduz o encruamento, e a substituição do material por outro menos suscetível ao fenômeno, como um com menor percentual de carbono. / In the ongoing pursuit to meet demands of an increasingly competitive market, companies have to reduce all their losses in the production process, therefore reducing costs and adding margin to their products. The main goal of this study was to investigate the phenomena present in the occurrence of ruptures of products originated from drawn and galvanized SAE 1057B steel, used in aerial cultivation. The study uses literature and laboratory research and a sample of thirty-six report concerning galvanized final and drawn intermediate product behavior. The data reference to product failure in any stage of the productive process or in field application. Along with testing a bibliographical research was made for conclusion support . Similarities were found between some authors studies and sample analysis of standardized tensile tests and winding over own axis tests from October 2010 to September 2011. The results shown that the primary phenomenon inducing wire failure in aerial cultivation wire is alignment of the hardening due to the high percentage area reductions in the drawing process that allows the development of the strain aging phenomenon after the hot dip galvanizing process witch has it´s effects enhanced by stress concentration points. Some solutions to mitigate the strain aging were proposed, like increasing the number of reduction passes for hardening reduction and the use of less susceptible material to the phenomena as a lower percentage carbon steel.
462

Ruptura total do tendão de Aquiles : propriedades mecânicas tendíneas em indivíduos submetidos a diferentes protocolos de reabilitação

Geremia, Jeam Marcel January 2011 (has links)
Introdução. Rupturas agudas do tendão de Aquiles afetam as propriedades mecânicas tendíneas. Estudos vêm preconizando o uso de mobilização precoce (tratamento acelerado) para evitar grandes prejuízos tendíneos. Entretanto, estudos que avaliem as propriedades mecânicas do tendão de Aquiles de humanos após ruptura total, submetidos à mobilização precoce, não foram encontrados na literatura específica da área. Objetivo: comparar as propriedades mecânicas e morfológicas do tendão de Aquiles entre pacientes submetidos a tratamento conservador e pacientes submetidos a tratamento acelerado (mobilização precoce) após a sutura do tendão de Aquiles. Materiais e Métodos: A amostra foi dividida intencionalmente em três grupos: controle (CTR; n=9), grupo conservador (CON; n=9; Pós-Cirúrgico: 28,3±3,6 meses) e grupo acelerado (ACE; n=9; Pós-Cirúrgico: 29,8±4,8 meses). Um dinamômetro isocinético foi utilizado para avaliação do torque dos grupos musculares flexores plantares e flexores dorsais do tornozelo. Foram obtidos os valores de área de secção transversa (AST) e comprimento do tendão (CT) de Aquiles. Para a avaliação da relação stress-strain os sujeitos realizaram duas contrações voluntárias máximas em rampa para flexão plantar no ângulo de 0º com duração de 10 segundos cada. Durante as duas contrações voluntárias máximas o deslocamento da JMT do músculo gastrocnêmio medial com o tendão de Aquiles foi verificado por meio de ultrassonografia utilizando uma sonda com arranjo linear. Simultaneamente a este procedimento, foi adquirido o sinal eletromiográfico do músculo tibial anterior, utilizado para a correção da força do tendão de Aquiles. As imagens necessárias para o cálculo do strain, bem como os sinais EMG e de torque foram sincronizados. Os valores máximos de stress, strain, força, deformação, módulo de Young, CT e AST foram comparados. Resultados: Não foram encontradas diferenças significativas nas propriedades mecânicas e morfológicas entre membros do grupo CTR. Não houve diferença significativa entre os membros saudáveis dos grupos CON e ACE e os do grupo CTR. Dessa forma, os membros saudáveis dos grupos CON e ACE foram utilizados como controle do membro lesão em ambos os grupos. Tanto no grupo CON, quanto no grupo ACE, o stress, a força e o módulo de Young apresentaram menores valores no membro lesionado, enquanto que o strain obtido em 10MPa e a AST foram maiores neste membro comparado ao contralateral saudável. Não houve diferença significativa no CT entre os membros, independente do grupo. Não foram encontradas diferenças significativas nas propriedades mecânicas, bem como na morfologia do tendão de Aquiles na comparação entre os membros lesionados dos grupos CON e ACE. Discussão: Esta maior complacência tendínea encontrada nos tendões lesados, independente do grupo, pode estar associada tanto as adaptações decorrentes da lesão que não recuperaram a níveis de normalidade, bem como a mudança nos hábitos de vida após a lesão. Além disso, o protocolo acelerado de reabilitação não foi capaz de reduzir as perdas advindas da ruptura tendínea. Tal resultado pode estar associado à especificidade do protocolo utilizado, que foi desenhado para ganho de flexibilidade no tornozelo e não para força muscular. Conclusão: Em um período mínimo de 21 meses de pós-operatório o tendão de Aquiles ainda apresenta efeitos deletérios da ruptura total nas propriedades estruturais e mecânicas do tendão. O protocolo de reabilitação utilizado não foi eficaz para a redução de tais efeitos. / Introduction. Acute Achilles tendon rupture affects the mechanical properties of the tendon. Despite the tendinous adaptations generated by decreased use, few studies have used early weight bearing (accelerated treatment) to avoid the large losses in the musculoskeletal tissues. In addition, studies that evaluated the mechanical properties of human Achilles tendon after acute rupture, subjected to early weight bearing were not found. Purpose: to compare the mechanical and morphological properties of the Achilles tendon between patients undergoing conservative and accelerated treatment, after Achilles tendon suture. Materials and Methods: subjects were intentionally allocated into three groups: control (CTR; n=9), conservative treatment (CON; n=9; Postsurgical time: 28.3±3.6 months) and accelerated treatment (ACC; n=9; Postsurgical time: 29.8±4.8 months). An isokinetic dynamometer was used to evaluate the torque production of ankle dorsi- and plantar-flexor muscles. The values of Achilles tendon cross sectional area (CSA) and length were obtained. To evaluate the stress-strain relation, patients were asked to produce two isometric maximal voluntary contractions during a ramp protocol (angle: neutral position; duration: 10 seconds) of the plantar flexor muscles. During the maximal contractions the displacement of the myotendinous junction of the gastrocnemius medialis muscle was evaluated by ultrasound with a linear array probe. Simultaneously, the electromyography (EMG) signal of the tibialis anterior was recorded, and used to correct the Achilles tendon force. The ultrasound images, EMG signals and torque were synchronized. The maximal values of stress, strain, force, displacement, Young’s modulus, tendon length and CSA were compared. Results: there were no significant differences in the morphological and mechanical properties between limbs in the CTR group. Moreover, there were no significant differences in the morphological and mechanical properties between healthy limbs amongst groups. Thus, the healthy limbs of the CON and ACC groups were used as control of the injured limb. In CON and ACC groups the stress, force and Young’s modulus had lower values in the injured limb compared to the contralateral healthy limb, while the strain obtained at 10MPa and the CSA were higher in the injured limb. There were no significant differences in the tendon length between groups and limbs. Moreover, there were no significant differences in the morphological and mechanical properties between injured limbs (CON and ACC). Discussion: The highest tendinous compliance found on the injured tendons, independent of the group might be associated to both the adaptations due to injury that did not return to normal healthy levels and to possible changes in the daily life activities after injury. In addition, the accelerated treatment was unable to reduce the losses due to tendon rupture. These results might be associated to the specificity of the rehabilitation protocol used that was designed for the gain of flexibility and not for strength gains. Conclusion: Twenty-one months post-surgery were unable to recover the deleterious effects of acute Achilles tendon rupture on the structural and mechanical tendon properties. The accelerated rehabilitation protocol was ineffective to reduce these deleterious effects.
463

Using Mechanical Strain as a Vehicle to Direct Fibroblasts-Mediated Myoblast Differentiation and Myotube Function

January 2014 (has links)
abstract: Skeletal muscle injury may occur from repetitive short bursts of biomechanical strain that impair muscle function. Alternatively, variations of biomechanical strain such as those held for long-duration are used by clinicians to repair muscle and restore its function. Fibroblasts embedded within the unifying connective tissue of skeletal muscle experience these multiple and diverse mechanical stimuli and respond by secreting cytokines. Cytokines direct all stages of muscle regeneration including myoblasts differentiation, fusion to form myotubes, and myotube functionality. To examine how fibroblasts respond to variations in mechanical strain that may affect juxtapose muscle, a myofascial junction was bioengineered that examined the interaction between the two cell types. Fibroblasts were experimentally shown to increase myoblast differentiation, and fibroblast biomechanical strain mediated the extent to which differentiation occurred. Intereleukin-6 is a strain-regulated cytokine secreted by fibroblasts was determined to be necessary for fibroblast-mediated myoblast differentiation. Myotubes differentiated in the presence of strained fibroblasts express greater number of acetylcholine receptors, greater acetylcholine receptor sizes, and modified to be more or less sensitive to acetylcholine-induced contraction. This study provides direct evidence that strained and non-strained fibroblasts can serve as a vehicle to modify myoblast differentiation and myotube functionality. Further understanding the mechanisms regulating these processes may lead to clinical interventions that include strain-activated cellular therapies and bioengineered cell engraftment for mediating the regeneration and function of muscle in vivo. / Dissertation/Thesis / Doctoral Dissertation Molecular and Cellular Biology 2014
464

Ruptura total do tendão de Aquiles : propriedades mecânicas tendíneas em indivíduos submetidos a diferentes protocolos de reabilitação

Geremia, Jeam Marcel January 2011 (has links)
Introdução. Rupturas agudas do tendão de Aquiles afetam as propriedades mecânicas tendíneas. Estudos vêm preconizando o uso de mobilização precoce (tratamento acelerado) para evitar grandes prejuízos tendíneos. Entretanto, estudos que avaliem as propriedades mecânicas do tendão de Aquiles de humanos após ruptura total, submetidos à mobilização precoce, não foram encontrados na literatura específica da área. Objetivo: comparar as propriedades mecânicas e morfológicas do tendão de Aquiles entre pacientes submetidos a tratamento conservador e pacientes submetidos a tratamento acelerado (mobilização precoce) após a sutura do tendão de Aquiles. Materiais e Métodos: A amostra foi dividida intencionalmente em três grupos: controle (CTR; n=9), grupo conservador (CON; n=9; Pós-Cirúrgico: 28,3±3,6 meses) e grupo acelerado (ACE; n=9; Pós-Cirúrgico: 29,8±4,8 meses). Um dinamômetro isocinético foi utilizado para avaliação do torque dos grupos musculares flexores plantares e flexores dorsais do tornozelo. Foram obtidos os valores de área de secção transversa (AST) e comprimento do tendão (CT) de Aquiles. Para a avaliação da relação stress-strain os sujeitos realizaram duas contrações voluntárias máximas em rampa para flexão plantar no ângulo de 0º com duração de 10 segundos cada. Durante as duas contrações voluntárias máximas o deslocamento da JMT do músculo gastrocnêmio medial com o tendão de Aquiles foi verificado por meio de ultrassonografia utilizando uma sonda com arranjo linear. Simultaneamente a este procedimento, foi adquirido o sinal eletromiográfico do músculo tibial anterior, utilizado para a correção da força do tendão de Aquiles. As imagens necessárias para o cálculo do strain, bem como os sinais EMG e de torque foram sincronizados. Os valores máximos de stress, strain, força, deformação, módulo de Young, CT e AST foram comparados. Resultados: Não foram encontradas diferenças significativas nas propriedades mecânicas e morfológicas entre membros do grupo CTR. Não houve diferença significativa entre os membros saudáveis dos grupos CON e ACE e os do grupo CTR. Dessa forma, os membros saudáveis dos grupos CON e ACE foram utilizados como controle do membro lesão em ambos os grupos. Tanto no grupo CON, quanto no grupo ACE, o stress, a força e o módulo de Young apresentaram menores valores no membro lesionado, enquanto que o strain obtido em 10MPa e a AST foram maiores neste membro comparado ao contralateral saudável. Não houve diferença significativa no CT entre os membros, independente do grupo. Não foram encontradas diferenças significativas nas propriedades mecânicas, bem como na morfologia do tendão de Aquiles na comparação entre os membros lesionados dos grupos CON e ACE. Discussão: Esta maior complacência tendínea encontrada nos tendões lesados, independente do grupo, pode estar associada tanto as adaptações decorrentes da lesão que não recuperaram a níveis de normalidade, bem como a mudança nos hábitos de vida após a lesão. Além disso, o protocolo acelerado de reabilitação não foi capaz de reduzir as perdas advindas da ruptura tendínea. Tal resultado pode estar associado à especificidade do protocolo utilizado, que foi desenhado para ganho de flexibilidade no tornozelo e não para força muscular. Conclusão: Em um período mínimo de 21 meses de pós-operatório o tendão de Aquiles ainda apresenta efeitos deletérios da ruptura total nas propriedades estruturais e mecânicas do tendão. O protocolo de reabilitação utilizado não foi eficaz para a redução de tais efeitos. / Introduction. Acute Achilles tendon rupture affects the mechanical properties of the tendon. Despite the tendinous adaptations generated by decreased use, few studies have used early weight bearing (accelerated treatment) to avoid the large losses in the musculoskeletal tissues. In addition, studies that evaluated the mechanical properties of human Achilles tendon after acute rupture, subjected to early weight bearing were not found. Purpose: to compare the mechanical and morphological properties of the Achilles tendon between patients undergoing conservative and accelerated treatment, after Achilles tendon suture. Materials and Methods: subjects were intentionally allocated into three groups: control (CTR; n=9), conservative treatment (CON; n=9; Postsurgical time: 28.3±3.6 months) and accelerated treatment (ACC; n=9; Postsurgical time: 29.8±4.8 months). An isokinetic dynamometer was used to evaluate the torque production of ankle dorsi- and plantar-flexor muscles. The values of Achilles tendon cross sectional area (CSA) and length were obtained. To evaluate the stress-strain relation, patients were asked to produce two isometric maximal voluntary contractions during a ramp protocol (angle: neutral position; duration: 10 seconds) of the plantar flexor muscles. During the maximal contractions the displacement of the myotendinous junction of the gastrocnemius medialis muscle was evaluated by ultrasound with a linear array probe. Simultaneously, the electromyography (EMG) signal of the tibialis anterior was recorded, and used to correct the Achilles tendon force. The ultrasound images, EMG signals and torque were synchronized. The maximal values of stress, strain, force, displacement, Young’s modulus, tendon length and CSA were compared. Results: there were no significant differences in the morphological and mechanical properties between limbs in the CTR group. Moreover, there were no significant differences in the morphological and mechanical properties between healthy limbs amongst groups. Thus, the healthy limbs of the CON and ACC groups were used as control of the injured limb. In CON and ACC groups the stress, force and Young’s modulus had lower values in the injured limb compared to the contralateral healthy limb, while the strain obtained at 10MPa and the CSA were higher in the injured limb. There were no significant differences in the tendon length between groups and limbs. Moreover, there were no significant differences in the morphological and mechanical properties between injured limbs (CON and ACC). Discussion: The highest tendinous compliance found on the injured tendons, independent of the group might be associated to both the adaptations due to injury that did not return to normal healthy levels and to possible changes in the daily life activities after injury. In addition, the accelerated treatment was unable to reduce the losses due to tendon rupture. These results might be associated to the specificity of the rehabilitation protocol used that was designed for the gain of flexibility and not for strength gains. Conclusion: Twenty-one months post-surgery were unable to recover the deleterious effects of acute Achilles tendon rupture on the structural and mechanical tendon properties. The accelerated rehabilitation protocol was ineffective to reduce these deleterious effects.
465

Estudo dos fenômenos que ocasionam quebras do arame Cultura Aérea derivados do aço SAE 1057B trefilado e galvanizado

Krug, Felipe January 2013 (has links)
Na busca contínua de atender as exigências de um mercado cada vez mais competitivo, as empresas devem buscar diminuir todas as suas perdas em seus processos produtivos, reduzindo custos e ganhando margem em seus produtos. Este trabalho teve como objetivo investigar os fenômenos presentes na ocorrência de quebras dos produtos derivados do aço SAE 1057B trefilado e galvanizado utilizado em culturas aéreas. O estudo utilizou bibliografia documental, pesquisa de laboratório e uma amostra composta por trinta e seis relatórios de análises sobre o desempenho do produto intermediário trefilado, ou do produto final galvanizado. Os dados referem-se à eventos de falhas do produto em quaisquer etapas do processo produtivo e mesmo de aplicação em campo. Juntamente com ensaios efetuados especificamente para amparar as conclusões destes relatórios, efetuou-se pesquisa bibliográfica para dar suporte às conclusões. Identificaram-se similaridades entre estudos de alguns autores e análises amostrais de testes padronizados de tração e enrolamento sobre o próprio eixo de outubro 2010 a setembro de 2011. Os resultados mostraram que o fenômeno que induz a um elevado índice de quebra do arame Cultura Aérea é o envelhecimento que ocorre posteriormente à sua passagem por elevadas reduções percentuais de área no processo de trefilação, que encrua o material, e em função de elevadas temperaturas encontradas no processo de galvanização, tendo, ainda, suas consequências amplificadas por pontos de concentração de tensões. Algumas soluções para amenizar a ocorrência do envelhecimento foram propostas, como o aumento do número de passes, o que reduz o encruamento, e a substituição do material por outro menos suscetível ao fenômeno, como um com menor percentual de carbono. / In the ongoing pursuit to meet demands of an increasingly competitive market, companies have to reduce all their losses in the production process, therefore reducing costs and adding margin to their products. The main goal of this study was to investigate the phenomena present in the occurrence of ruptures of products originated from drawn and galvanized SAE 1057B steel, used in aerial cultivation. The study uses literature and laboratory research and a sample of thirty-six report concerning galvanized final and drawn intermediate product behavior. The data reference to product failure in any stage of the productive process or in field application. Along with testing a bibliographical research was made for conclusion support . Similarities were found between some authors studies and sample analysis of standardized tensile tests and winding over own axis tests from October 2010 to September 2011. The results shown that the primary phenomenon inducing wire failure in aerial cultivation wire is alignment of the hardening due to the high percentage area reductions in the drawing process that allows the development of the strain aging phenomenon after the hot dip galvanizing process witch has it´s effects enhanced by stress concentration points. Some solutions to mitigate the strain aging were proposed, like increasing the number of reduction passes for hardening reduction and the use of less susceptible material to the phenomena as a lower percentage carbon steel.
466

Medição de tensões em componentes mecânicos utilizando a técnica ESPI / Stress measurement in mechanical components applying the ESPI technique

Saito, Edson Hiroshi 16 August 2018 (has links)
Orientador: Auteliano Antunes dos Santos Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecânica / Made available in DSpace on 2018-08-16T17:18:43Z (GMT). No. of bitstreams: 1 Saito_EdsonHiroshi_M.pdf: 2483546 bytes, checksum: f0889b176e6cc7896851b8620c53c361 (MD5) Previous issue date: 2010 / Resumo: A técnica ESPI, sigla em inglês - Electronic Speckle Pattern Interferometry -, ou ainda, Interferometria Eletrônica por Padrão de Speckle, surgiu em conseqüência do desenvolvimento da metrologia a laser, que possui como característica o chamado efeito speckle. Este efeito é o fenômeno óptico de interferência de ondas eletromagnéticas coerentes - que é o caso do Laser - que possibilita a geração de padrões de franjas de interferência, a partir das quais é possível medir o deslocamento de superfícies e posteriormente calcular as tensões e deformações. Por se tratar de uma metodologia não destrutiva e sensível a pequenos deslocamentos, essa metodologia tem se difundido na indústria para medição de Tensões em componentes mecânicos de formas complexas e como aplicação de apoio para outras técnicas como análise por Elementos Finitos. O objetivo deste trabalho é a aplicação da técnica ESPI em componentes mecânicos fazendo uso de uma metodologia através da qual seja possível estabelecer um procedimento de medição da tensão com confiabilidade. O desafio é estabelecer a adequada aplicação da ferramenta em ambiente industrial, onde há a interferência de ruídos, temperatura, vibração, além de uma adequação de equipamentos de ensaio que pode influenciar diretamente nos resultados de medições. A correta medição das tensões e deformações através de um ensaio não destrutivo e de rápido diagnóstico pode trazer diversos benefício, dentre os quais as cifras gastas em peças destruídas, tempo de medição e economia de mão-de-obra. Os resultados do presente trabalho são a determinação das variáveis influentes na aplicação do ESPI, levantamento das causas raízes dos problemas de medição e, a partir dessas informações, consolidar um procedimento padrão para aplicação em medição de tensões em componentes utilizando a técnica ESPI / Abstract: The ESPI technique - Electronic Speckle Pattern Interferometry - has emerged as a result of the development of laser metrology, which is characterized as the so-called speckle effect. This effect is an optical phenomenon of coherent electromagnetic waves interference - as Laser. It allows the generation of fringes interference from which it can be measured the displacement of surfaces and therefore calculated the stresses and strains. As a no-destructive methodology and being sensible to small displacements, it has being spread out in the industry by measuring Stress and Displacements in complex mechanical components and as a support to Finite Elements Analysis (FEA) and others techniques. The objective of this work is the application of the ESPI technique testing mechanical components making use of a systematic methodology by which it will be able to establish a procedure for measuring stress with reliability. The challenge is to establish the application procedure in the industrial environment, where there are a lot of interferences like noises, temperature variation, vibration etc., besides the fact that the testing equipment to be adapted to static tests can influences in the results. The stress and displacements measurement in a nodestructive test and fast result diagnose can bring a lot of benefits in financial terms serving as a support tool for other testing procedures. The results from this project are the determination of main variables for ESPI application, establishment of root causes in measurements problems using ESPI, and hence consolidate a standard procedure for ESPI application in strain /stress measurement in mechanical components / Mestrado / Mecanica dos Sólidos e Projeto Mecanico / Mestre em Engenharia Mecânica
467

Uma abordagem da vida em fadiga em barra estabilizadora automotiva considerando defeito superficial fisicamente pequeno

COLOSIO, MARCO A. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:48:51Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:09Z (GMT). No. of bitstreams: 1 09601.pdf: 14581150 bytes, checksum: 039930ea0467d8cb98d0f2a68ecb3072 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
468

Análise da técnica óptica de Moiré como método fotomecânico para qualificação e quantificação de tensões / Use of optical techniques applied on stress distribution study of reduced bundle log models and sawn pieces

Gazzola, Jonathan, 1981- 10 July 2013 (has links)
Orientador: Inácio Maria Dal Fabbro / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agrícola / Made available in DSpace on 2018-08-23T11:41:51Z (GMT). No. of bitstreams: 1 Gazzola_Jonathan_D.pdf: 4193064 bytes, checksum: cfa66521e595db19afcd4c8f16250515 (MD5) Previous issue date: 2013 / Resumo: A distribuição de tensões em corpos dá suporte à engenharia de projetos visando à melhoria da qualidade e segurança de produtos e atualmente são determinados por métodos analíticos e experimentais. A vantagem dos métodos experimentais em relação aos métodos analíticos está em analisar a distribuição de tensões e deformações independentemente das condições do material e de sua geometria. Entre os métodos experimentais, as técnicas ópticas que tem se demonstrado propícias são holografia, speckle interferométrico e as técnicas de moiré. As técnicas ópticas interferométricas permitem determinar campos de deslocamento, porém, quando combinados com métodos híbridos se tornam passíveis de determinação do componente de tensões e deformações específicas e são comumente conhecidas como técnicas fotomecânicas. As técnicas de moiré são conhecidas por sua habilidade em determinar topografia de objetos, porém, pesquisas recentes têm mostrado muito útil em determinar campo de deslocamento. A técnica de moiré é baseada na fenomenologia moiré, na qual, duas grades superpostas produzem franjas padrões e, por meio de tratamento de imagem adequado permite deduzir qualitativamente o mapa de distribuição de tensões e deformações. Os principais tipos de técnicas de moiré são de sombra e por phase-shifting e seu arranjo experimental consiste no uso de equipamentos de baixo custo, o que o torna altamente viável, frente às outras técnicas ópticas. A proposta deste trabalho de pesquisa se identifica em analisar o uso da técnica de moiré por phase-shifting para determinação de tensões e deformações de forma qualitativa e quantitativa a partir do campo de deslocamento determinado experimentalmente. Para validação, os resultados gerados pela técnica de moiré foram comparados com os resultados obtidos por ensaio experimental de extensometria elétrica e simulação computacional. Os resultados mostraram que qualitativamente, a técnica de moiré foi hábil em determinar campo de deslocamento, enquanto que, quantitativamente a técnica foi hábil em determinar campo de deslocamento, deformações e tensões / Abstract: Stress distribution in specimens supports the design engineering objectiving quality and insurance products improvement and actually are determined through analytical and experimental analyses. Analyzes of stress and strain distribution independently of material conditions and its geometry becomes advantage of experimental methods, in relation to analytical methods. Among experimental methods, optical techniques have demonstrated to be favorable are holography, interferometrical speckle and moiré techniques. Interferometrical optical techniques allow to determine displacement fields, but, when associated to hybrid methods, they become able to stress and strain components determination and they are usually named as photomechanical technique. Moiré technique is known for its hability to determine shape surface, but, researches have demonstrated to be usefull to determine displacement field. Moiré technique is based about moiré phenomenology, which, two superposed grids produces pattern fringes and, applying an adequated image treatment is possible to deduce qualitatively the stress and strain distribution mapping. The main kind of moiré technique are shadow and phase-shifting and its setup is based in use of low cost equipments, which becomes highly feasible, when compared to other optical techniques. This research work objectives to analyze the use of phase-shifting moiré technique to stress and strain determination qualitative and quantitatively using datas of displacement field determined experimentally. Results obtained through moiré technique were validated comparing results obtained through etectrical extensometry experimental tests and computational simulation. Results showed that qualitatively, moiré technique was able to determine displacement field, while quantitatively moiré was able to determine displacement, strain and stress / Doutorado / Maquinas Agricolas / Doutor em Engenharia Agrícola
469

Compactação do solo gerada por pneus de alta flutuação de eixo livre e trativo / Soil compaction generated by high flotation tires of free and tractive axle

Barbosa, Luís Alfredo Pires 20 August 2018 (has links)
Orientador: Paulo Sérgio Graziano Magalhães / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Agrícola / Made available in DSpace on 2018-08-20T20:08:08Z (GMT). No. of bitstreams: 1 Barbosa_LuisAlfredoPires_M.pdf: 3080988 bytes, checksum: cb9123dca7959f9d728490292de1f6e9 (MD5) Previous issue date: 2012 / Resumo: O aumento da mecanização das lavouras gera o emprego de máquinas cada vez mais potentes e, a potência possui relação direta com o peso. Aumentando-se o tráfego de máquinas pesadas sobre o solo o emprego do pneu correto é de suma importância para se minimizar os efeitos da compactação. Com as diferenças entre os modelos de pneus de alta flutuação para eixos livres e trativos (com garras) e o comum emprego de pneus trativos em eixos livres devido ao seu custo de imposto ser reduzido, questionou-se a possibilidade de o emprego do pneu mais barato estar prejudicando a produtividade, pelo fato de apresentar uma área de contato possivelmente menor. Objetivou-se ao estudo comparativo entre dois modelos de pneus de alta flutuação da mesma medida, porém um para eixos livres e outro para eixos trativos. Os experimentos foram conduzidos em caixa de solos e também em superfície rígida, sob condições controladas, realizando-se ensaios estáticos para duas cargas radiais (16 e 29 kN), medindo-se deformações, áreas de contato e compactação do solo, sendo feita uma análise estatística fatorial, com os fatores pneu e carga, sendo realizados 8 ensaios, totalizando 32 observações. Obteve-se como resultados, deformações maiores para o pneu trativo, bem como área de contato maior e compactações menores, que o pneu de eixo livre, isso porque a área de contato do pneu trativo envolve não somente as garras, mas também o fundo íncavo (região entre garras), para o solo estudado, e o fato do pneu possuir uma quantidade de composto de borracha menor em sua banda de rodagem, quando comparado com o pneu de eixo livre, aumenta a flexibilidade da rodagem, melhorando sua capacidade de deformação e consequentemente aumentando sua área de contato com o solo / Abstract: The increased mechanization in farming generates employment of ever more powerful machines, and power has direct relationship with the weight. Increasing traffic of heavy machinery on the ground the use of correct tire is of paramount importance to minimize the effects of compaction. With the differences between models of high-flotation tires for free and trative axes, especially regarding the presence of claws, and the common use of tires trative on free axes because of the cost of tax be reduced, questioned the possibility of employment tire cheaply be hindering productivity, because this has a contact area possibly lower. The objective is then to the comparative study between two models of high-flotation tires the same size, but one for free axes and another for trative axes. The experiments were conducted in soil bin and also in rigid surface, under controlled conditions, performing static tests for two radial loads (16 and 29 kN), by measuring deformation, contact areas and soil compaction, and made a factorial statistical analysis with the tire and load factors, was conducted 8 tests, totaling 32 observations. Was obtained as result, larger deformations for the trative tire as well as larger contact area and less compaction of the soil that tire of free axis, that because the contact area of the tire tractive involves not just the claws, but also the region between them and the fact that the tire has a much lower rubber compound in its tread, when compared with tire of free axis, increases flexibility, enhancing their ability to deformation and consequently increasing its contact area with the ground, reducing the compaction of soil / Mestrado / Maquinas Agricolas / Mestre em Engenharia Agrícola
470

TCAD based SiGe HBT advanced architecture exploration

Al-S'adi, Mahmoud 25 March 2011 (has links)
Dans le but d’améliorer les transistors bipolaires TBH SiGe, nous proposons d’étudier l’impact de la contrainte mécanique sur leurs performances. En effet, cette contrainte permet de libérer un degré de liberté supplémentaire pour améliorer les propriétés du transport grâce à un changement de la structure de bande d’énergie du semiconducteur. Ainsi, nous avons proposé de nouvelles architectures de composants basées sur l’ingénierie de la contrainte mécanique dans les semiconducteurs. Deux approches ont été utilisées dans cette étude pour générer la tension mécanique adéquate à l'intérieur du dispositif. La première approche consiste à appliquer une contrainte mécanique sur la base du transistor en utilisant une couche de SiGe extrinsèque. La seconde approche vise à appliquer une contrainte dans la région du collecteur en utilisant une couche contrainte. Les résultats obtenus montrent que cette méthode peut être une approche prometteuse pour améliorer les performances des TBH. / The Impact of strain engineering technology applied on Si BJT/SiGe HBT devices on the electrical properties and frequency response has been investigated. Strain technology can be used as an additional degree of freedom to enhance the carriers transport properties due to band structure changes and mobility enhancement. New concepts and novel device architectures that are based on strain engineering technology have been explored using TCAD modeling. Two approaches have been used in this study to generate the proper mechanical strain inside the device. The first approach was through introducing strain at the device’s base region using SiGe extrinsic stress layer. The second approach was through introducing strain at the device’s collector region using strain layers. The obtained results obviously show that strain engineering technology principle applied to BJT/HBT device can be a promising approach for further devices performance improvements.

Page generated in 0.0803 seconds