• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 8
  • 4
  • 2
  • Tagged with
  • 15
  • 15
  • 11
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Controle robusto de inversores VSI com filtro LCL aplicados a geração distribuída, com controle da injeção de potências ativa e reativa na rede de distribuição em baixa tensão e capacidade de operação ilhada em ambiente de microrredes / Robust control of voltage source inverters with LCL filters suitable for distributed generation, with control of the injection of active and reactive power on the low voltage distribution network and capability to operate in islanded mode in microgrid scenario

Pena, José Carlos Ugaz [UNESP] 02 June 2016 (has links)
Submitted by JOSÉ CARLOS UGAZ PEÑA null (josecarlos84@gmail.com) on 2016-06-20T13:29:30Z No. of bitstreams: 1 Tese_JoseCarlosPena_PPGEE.pdf: 9650212 bytes, checksum: 77b105d009c0b473cbc424e681ebe9a5 (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-06-22T13:10:00Z (GMT) No. of bitstreams: 1 pena_jcu_dr_ilha.pdf: 9650212 bytes, checksum: 77b105d009c0b473cbc424e681ebe9a5 (MD5) / Made available in DSpace on 2016-06-22T13:10:00Z (GMT). No. of bitstreams: 1 pena_jcu_dr_ilha.pdf: 9650212 bytes, checksum: 77b105d009c0b473cbc424e681ebe9a5 (MD5) Previous issue date: 2016-06-02 / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Os inversores fonte de tensão com filtro de saída LCL (VSI+LCL) são amplamente utilizados em sistemas de geração distribuída. Nestas aplicações o sistema é controlado como uma fonte de corrente, no entanto, há a possibilidade de controlar o conjunto como uma fonte de tensão. Desta forma, a mencionada configuração pode ser utilizada em geração distribuída no ambiente de microrredes onde os sistemas, monofásicos ou trifásicos, devem operar conectados à rede de distribuição elétrica com controle das potências injetadas (ativa e reativa) e serem capazes de, em ausência da rede, passar a operar no modo autônomo. Ainda, após o restabelecimento da rede, o controle deve levar o sistema a operar novamente no modo conectado. Sendo as transições realizadas sem transientes que possam danificar qualquer componente do sistema. O filtro LCL, de terceira ordem, caracteriza um comportamento ressonante que pode comprometer a estabilidade do sistema. Para resolver esta situação, diversas técnicas ativas e passivas são aplicadas. Para aplicações de baixa potência, preferem-se as técnicas passivas de amortecimento devido a sua simplicidade e baixo custo, porém estas implicam em perdas adicionais. Já as técnicas ativas de amortecimento, consideram procedimentos de controle para atenuar a ressonância, e, portanto, não adicionam perdas, porém, sua realização requer da realimentação de variáveis adicionais elevando assim o custo do sistema. Todavia, mesmo que aplicáveis a ambos os modos de operação, as técnicas de amortecimento disponíveis na literatura consideram apenas um modo de operação. O presente trabalho de doutorado explora a possibilidade de controlar sistemas VSI+LCL, monofásicos e trifásicos, em ambos os modos de operação, com atenção a objetivos específicos em cada modo e transições suaves entre estes. Assim, são apresentadas duas estratégias de controle. A primeira estratégia considera o amortecimento da ressonância por técnicas passivas, mediante a utilização de um ramo de amortecimento de segunda ordem, projetado para garantir o efeito desejado em ambos os modos de operação e simplificar a dinâmica do sistema a fim de facilitar o projeto dos controladores, abordagem não utilizada nos métodos conhecidos na literatura. Logo, o sistema amortecido é controlado em uma configuração de duas malhas, controlando a corrente injetada mediante a tensão no capacitor. A segunda estratégia proposta considera a utilização de controladores por realimentação de estados em tempo discreto, sintetizados mediante desigualdades matriciais lineares, para simultaneamente, realizar ativamente o amortecimento da ressonância e atender os objetivos de controle em ambos os modos de operação. Ambas as estratégias propostas consideram controladores ressonantes com o objetivo de rastrear sinais senoidais de referência com erro nulo e suprimir componentes harmônicos de baixa ordem na corrente de saída. Ainda, os controladores são projetados considerando a necessidade de garantir a estabilidade robusta do sistema, isto é, frente a perturbações externas (tais como variações na carga local, oscilações na tensão do barramento CC ou distúrbios na rede) e às variações em parâmetros do sistema, como a indutância de rede. As propostas são apresentadas em detalhe, incluindo os procedimentos de projeto assim como critérios para a geração e coordenação dos sinais de controle e referência. As estratégias propostas são avaliadas experimentalmente sendo os resultados obtidos discutidos e analisados considerando-se as respectivas normas para os casos de operação conectada e ilhada. / The voltage source inverter utilization with LCL filters (VSI+LCL) is extended in Distributed Electrical Energy Systems. In these applications, the system is controlled as a current source, however, it can also be controlled as a voltage source. Hence, this configuration is suitable for microgrids environment. In this scenario, the system should operate connected to utility grid with control of the supplied power (active or reactive) and also be capable, in case of grid absence, to operate in islanded mode. Then, if the grid is reestablished, system should be reconnected to grid. Moreover, these transitions should be smooth, with no hazardous transients. The third order filter leads to a resonant behavior that can compromise the system stability. In order to overcome this limitation, passive and active damping methods are used. In low power applications, passive damping methods are preferred due to their simplicity and low. Nevertheless, these methods lead to additional losses. On the other hand, active damping methods consider the feedback of additional variables in order to damp the resonance in closed loop, with no additional losses. This implies additional sensors, thus increasing the overall cost. Despite their effectiveness to damp the resonance in both autonomous and grid connected applications, the most of the damping methods are usually designed only for a specific operation mode. This work explores the possibility to control VSI+LCL systems, single and three-phase, in both operation modes, attending to specific goals in each one, and with smooth transitions between them. For that purpose, two control strategies are proposed. The first one considers passive damping methods, by using a second order damping branch which is designed in order to guarantee the desired effect in both operation modes, thus simplifying the system dynamics in order to ease the control. This approach is not known in the literature. Then, the damped system is controlled in a two loop strategy, where the output current is controlled by means of the capacitor voltage. The second strategy considers the utilization of discrete time state-feedback controllers, synthesized by Linear Matrix Inequalities, in order to simultaneously achieve the active damping and the control goals for both operation modes. The proposed strategies use resonant controllers in order to achieve the tracking of sinusoidal references and to suppress low order harmonics in the output current. Moreover, controllers are designed to achieve robust stability of the system, thus, even in front of external disturbances (such as local load variations, DC bus oscillations or grid disturbances) and variation on system parameters, such as the grid inductance. The two introduced strategies are detailed including the design procedure and the criterion to generate and coordinate the reference and control signals. The two proposed strategies were experimentally verified. The results were analyzed and compared to the requirements imposed by the related standards for both modes of operation. / CNPq: 141757/2012-4
12

Controle robusto de inversores VSI com filtro LCL aplicados a geração distribuída, com controle da injeção de potências ativa e reativa na rede de distribuição em baixa tensão e capacidade de operação ilhada em ambiente de microrredes /

Pena, José Carlos Ugaz January 2016 (has links)
Orientador: Carlos Alberto Canesin / Resumo: Os inversores fonte de tensão com filtro de saída LCL (VSI+LCL) são amplamente utilizados em sistemas de geração distribuída. Nestas aplicações o sistema é controlado como uma fonte de corrente, no entanto, há a possibilidade de controlar o conjunto como uma fonte de tensão. Desta forma, a mencionada configuração pode ser utilizada em geração distribuída no ambiente de microrredes onde os sistemas, monofásicos ou trifásicos, devem operar conectados à rede de distribuição elétrica com controle das potências injetadas (ativa e reativa) e serem capazes de, em ausência da rede, passar a operar no modo autônomo. Ainda, após o restabelecimento da rede, o controle deve levar o sistema a operar novamente no modo conectado. Sendo as transições realizadas sem transientes que possam danificar qualquer componente do sistema. O filtro LCL, de terceira ordem, caracteriza um comportamento ressonante que pode comprometer a estabilidade do sistema. Para resolver esta situação, diversas técnicas ativas e passivas são aplicadas. Para aplicações de baixa potência, preferem-se as técnicas passivas de amortecimento devido a sua simplicidade e baixo custo, porém estas implicam em perdas adicionais. Já as técnicas ativas de amortecimento, consideram procedimentos de controle para atenuar a ressonância, e, portanto, não adicionam perdas, porém, sua realização requer da realimentação de variáveis adicionais elevando assim o custo do sistema. Todavia, mesmo que aplicáveis a ambos os modos de operação,... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The voltage source inverter utilization with LCL filters (VSI+LCL) is extended in Distributed Electrical Energy Systems. In these applications, the system is controlled as a current source, however, it can also be controlled as a voltage source. Hence, this configuration is suitable for microgrids environment. In this scenario, the system should operate connected to utility grid with control of the supplied power (active or reactive) and also be capable, in case of grid absence, to operate in islanded mode. Then, if the grid is reestablished, system should be reconnected to grid. Moreover, these transitions should be smooth, with no hazardous transients. The third order filter leads to a resonant behavior that can compromise the system stability. In order to overcome this limitation, passive and active damping methods are used. In low power applications, passive damping methods are preferred due to their simplicity and low. Nevertheless, these methods lead to additional losses. On the other hand, active damping methods consider the feedback of additional variables in order to damp the resonance in closed loop, with no additional losses. This implies additional sensors, thus increasing the overall cost. Despite their effectiveness to damp the resonance in both autonomous and grid connected applications, the most of the damping methods are usually designed only for a specific operation mode. This work explores the possibility to control VSI+LCL systems, single and three-phase... (Complete abstract click electronic access below) / Doutor
13

Corrente de fuga em inversores monofásicos sem transformador para conexão de sistemas fotovoltaicos à rede de distribuição de energia elétrica: análise e proposta de filtro passivo integrado de modo comum e diferencial. / Leakage current in single-phase transformerless inverters for the connection of photovoltaic systems to the distribution grid: analysis and proposal of an integrates common and differential mode passive filter.

Ricardo Souza Figueredo 21 May 2015 (has links)
Este trabalho apresenta um estudo sobre a corrente de fuga de modo comum em inversores monofásicos sem transformador utilizados para a conexão de sistemas fotovoltaicos (FV) à rede de distribuição de energia elétrica. O estudo se concentra em inversores do tipo fonte de tensão que empregam a topologia em ponte completa. A partir da adequada modelagem do sistema (rede, conversor e módulo fotovoltaico) identifica-se e quantifica-se a contribuição das tensões de modo comum e modo diferencial para a corrente de fuga. Conclui-se que a tensão de modo comum de alta frequência produzida pelo inversor, que depende da estratégia de modulação por largura de pulso (PWM Pulse Width Modulation) empregada, fornece a maior contribuição para produção da corrente de fuga. Esse estudo mostra que os inversores sem transformador, com topologia em ponte completa e modulação que produz tensão de saída com três níveis, necessitam de medidas adicionais para a minimização da corrente fuga quando aplicados em sistemas fotovoltaicos conectados à rede. Algumas soluções propostas na literatura para a minimização da corrente de fuga baseadas em topologias modificadas e filtros de modo comum são listadas e discutidas. Neste trabalho é proposto um filtro integrado de modo comum e modo diferencial com amortecimento passivo de baixas perdas, para minimizar a corrente de fuga produzida por um inversor monofásico sem transformador. Um exemplo de aplicação do filtro proposto é apresentado juntamente com seu procedimento de projeto, resultados de simulação e experimentais que validam a proposta. Além disso, a influência da variação da indutância da rede elétrica e da capacitância parasita do sistema fotovoltaico no comportamento do filtro proposto é analisada. A influência da variação da indutância da rede no comportamento do sistema de controle e o impacto da corrente de modo comum no projeto dos indutores do lado do conversor também são analisados. / This paper presents a study on the common mode leakage current in single-phase transformerless inverters for grid-connected photovoltaic (PV) systems. The study focuses on voltage source inverters (VSI) employing the full-bridge topology. The common mode and differential mode voltages that contribute to the leakage current are identified and quantified from the analysis of the system model (utility grid, converter and PV module). The system model analysis shows that the high frequency common mode voltage produced by the inverter, which depends on the Pulse Width Modulation (PWM) strategy, is the main source contributing to the leakage current. This work shows that transformerless inverters employing the full-bridge topology and a modulation strategy that produces a three-level output voltage require some leakage current minimization strategy when they are employed in grid-connected PV systems. Some solutions proposed in the literature for leakage current minimization based on modified topologies and common mode filters are listed and discussed. In this dissertation an integrated common and differential filter with low loss passive damping is proposed to minimize the leakage current produced by a single-phase transformerless PV inverter. An application example of the proposed filter is presented with design procedure, simulation and experimental results validating the proposal. Additionally, the influence of grid inductance and PV module parasitic capacitance variations on the behavior of the proposed filter is analyzed. The behavior of the control system considering the grid inductance variation and the impact of the common mode current on the converter side inductors design are also analyzed.
14

Corrente de fuga em inversores monofásicos sem transformador para conexão de sistemas fotovoltaicos à rede de distribuição de energia elétrica: análise e proposta de filtro passivo integrado de modo comum e diferencial. / Leakage current in single-phase transformerless inverters for the connection of photovoltaic systems to the distribution grid: analysis and proposal of an integrates common and differential mode passive filter.

Figueredo, Ricardo Souza 21 May 2015 (has links)
Este trabalho apresenta um estudo sobre a corrente de fuga de modo comum em inversores monofásicos sem transformador utilizados para a conexão de sistemas fotovoltaicos (FV) à rede de distribuição de energia elétrica. O estudo se concentra em inversores do tipo fonte de tensão que empregam a topologia em ponte completa. A partir da adequada modelagem do sistema (rede, conversor e módulo fotovoltaico) identifica-se e quantifica-se a contribuição das tensões de modo comum e modo diferencial para a corrente de fuga. Conclui-se que a tensão de modo comum de alta frequência produzida pelo inversor, que depende da estratégia de modulação por largura de pulso (PWM Pulse Width Modulation) empregada, fornece a maior contribuição para produção da corrente de fuga. Esse estudo mostra que os inversores sem transformador, com topologia em ponte completa e modulação que produz tensão de saída com três níveis, necessitam de medidas adicionais para a minimização da corrente fuga quando aplicados em sistemas fotovoltaicos conectados à rede. Algumas soluções propostas na literatura para a minimização da corrente de fuga baseadas em topologias modificadas e filtros de modo comum são listadas e discutidas. Neste trabalho é proposto um filtro integrado de modo comum e modo diferencial com amortecimento passivo de baixas perdas, para minimizar a corrente de fuga produzida por um inversor monofásico sem transformador. Um exemplo de aplicação do filtro proposto é apresentado juntamente com seu procedimento de projeto, resultados de simulação e experimentais que validam a proposta. Além disso, a influência da variação da indutância da rede elétrica e da capacitância parasita do sistema fotovoltaico no comportamento do filtro proposto é analisada. A influência da variação da indutância da rede no comportamento do sistema de controle e o impacto da corrente de modo comum no projeto dos indutores do lado do conversor também são analisados. / This paper presents a study on the common mode leakage current in single-phase transformerless inverters for grid-connected photovoltaic (PV) systems. The study focuses on voltage source inverters (VSI) employing the full-bridge topology. The common mode and differential mode voltages that contribute to the leakage current are identified and quantified from the analysis of the system model (utility grid, converter and PV module). The system model analysis shows that the high frequency common mode voltage produced by the inverter, which depends on the Pulse Width Modulation (PWM) strategy, is the main source contributing to the leakage current. This work shows that transformerless inverters employing the full-bridge topology and a modulation strategy that produces a three-level output voltage require some leakage current minimization strategy when they are employed in grid-connected PV systems. Some solutions proposed in the literature for leakage current minimization based on modified topologies and common mode filters are listed and discussed. In this dissertation an integrated common and differential filter with low loss passive damping is proposed to minimize the leakage current produced by a single-phase transformerless PV inverter. An application example of the proposed filter is presented with design procedure, simulation and experimental results validating the proposal. Additionally, the influence of grid inductance and PV module parasitic capacitance variations on the behavior of the proposed filter is analyzed. The behavior of the control system considering the grid inductance variation and the impact of the common mode current on the converter side inductors design are also analyzed.
15

Integrated Common And Differential Mode Filters With Active Damping For Active Front End Motor Drives

Acharya, Anirudh B 01 1900 (has links) (PDF)
IGBT based power converters acts as front end in the present day Adjustable Speed Drive (ASD). This offers many advantages and makes regenerative action possible. PWM rectifier operation produces electrically noisy DC bus on common mode basis. This results in higher ground current as compared to three phase diode bridge rectifier. Due to fast turn-ON and turn-OFF time of IGBT, the inverter output voltage dv/dt is high during switching transients and voltage waveform is rich in harmonics. As a result, in applications involving long cable the motor terminal voltage during the switching transient is as high as twice the applied voltage. This voltage stress reduces the life of insulation in motors. The high dv/dt output voltage applied at the motor terminal excites the parasitic capacitive coupling resulting in increased ground currents and causes Electric Discharge Machining (EDM) which reduces the life of motor bearings. The common mode voltage due to PWM rectifier and the inverter appear at the motor terminals exacerbating these problems. The common mode voltage due to PWM inverter with PWM rectifier is analyzed. An integrated approach for filter design is proposed wherein the adverse effects due to common mode voltage of both AFE converter and the inverter is addressed. The proposed topology addresses the problems of common mode voltage, common mode current and voltage doubling due to ASD. The design procedure for proposed filter topology is discussed with experimental results that validate the effectiveness of the filter. Inclusion of such higher order filter in the converter topology leads to problems such as resonance. Passive methods are investigated for damping the line resonance due to LCL filter and common mode resonance due to common mode filter. The need for active damping technique for resonance due to common mode filter is presented. State space based damping technique is proposed to effectively damp the resonance due to line filter and the common mode filter. Experimental results are presented that validate the effectiveness of active damping both on the line basis (differential mode) and line to ground basis (common mode) of the filter.

Page generated in 0.1436 seconds