• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • Tagged with
  • 22
  • 22
  • 16
  • 13
  • 4
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Punção em lajes: exemplos de cálculo e análise teórico-experimental / Punching shear in slabs: examples of calculation and theoretic-experimental analysis

José Luiz Pinheiro Melges 28 August 1995 (has links)
Atualmente, alguns códigos como o CEB/90 e o texto base da NB-1/94 (ainda em fase de apreciação pelo meio técnico) têm apresentado inovações com relação à verificação da resistência à punção. Fez-se então, neste trabalho, uma análise do texto base da NB-1/94 referente à punção, comparando suas recomendações com algumas das fornecidas pelo CEB/90. Observou-se uma certa divergência entre os dois códigos com relação a pilares de borda e de canto, fornecendo o CEB/90 um tratamento mais simplificado para essas duas situações. Além disso, observa-se que, ao contrário do CEB/90, o texto base não menciona as seguintes recomendações: utilização de uma armadura a ser disposta ao longo das bordas livres da laje, destinada a combater esforços de torção, e limitação da resistência do concreto em 50 MPa para essas verificações. Observou-se, ainda, uma omissão desses dois códigos com relação à situação de pilares internos submetidos a momentos fletores atuando em duas direções diferentes. Sugere-se, ainda, ao texto base, a inclusão de expressões que visem a facilitar e agilizar a sua aplicação. Após essa análise, foram apresentados exemplos de cálculo para pilares internos, de borda e de canto, tanto com como sem armadura de punção, verificados segundo as recomendações do texto base da NB-1/94, do EUROCODE N.2, do CEB/90 e do ACI 318/89. Por fim, comparam-se resultados experimentais com valores dados por estes códigos, visando determinar suas respectivas eficiências frente a alguns parâmetros, tais como, por exemplo, a presença de armadura transversal ou a relação entre os lados do pilar. Verifica-se que a utilização de armaduras de combate à punção pode elevar substancialmente o valor da resistência da ligação, além de torná-la mais dúctil. As observações referentes à comparação entre os valores fornecidos através de ensaios e os dados pelos códigos devem ser levadas em consideração apenas como uma indicação de seus respectivos comportamentos, necessitando-se de mais dados para uma afirmação mais conclusiva. / Nowadays, some standards like CEB/90 and the Brazilian code basic text NB-1/94 (not approved yet) have presented some innovations for the punching shear strength. In this work, a comparative analysis is presented about the NB1-94 basic text recommendations and some presented by the CEB/90. Some differences are noted between the NB1-94 basic text and the CEB/90 recommendations relatives to corner and edge columns. The CEB/90 has a simplified treatment for these situations. lt is noted that, in opposition to the CEB/90, the NB1-94 basic text about punching shear strength does not mention an additional reinforcement to be placed at the free edges of the slab, to provide torsion strength, and neither have a limit value of 50 MPa for the concrete compressive strength. lt is also noted that the CEB/90 and the NB1-94 basic text do not have a recommendation for internal columns with bending moments acting on two different directions. lt is suggested that the NB1-94 basic text includes some expressions that can make its application easier and faster. After this analysis, some examples are presented with internal, edge and corner columns, with and without shear reinforcement, verified by the NB1-94 basic text, the EUROCODE N.2, the CEB/90 and the ACI 318/89 recommendations. Finally, a comparative analysis between some experimental results and those given by the codes is presented. The experimental results were related to some parameters like, for instance, the presence of shear reinforcement or the column sides ratio. lt is verified that the shear reinforcement utilization can give more resistance and ductility to the connection. Finally, it is noted that the observations about the comparison between the experimental results and the values given by the codes can just be taken like a behavior indication for the connections. For conclusive affirmations, more experimental analysis are necessary.
22

Comportamento à punção de lajes de concreto armado tipo bubbledeck / Punching behaviour of bubbledeck type reinforced concrete flat plates

Nicácio, Wanderley Gustavo 22 March 2018 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2018. / Submitted by Fabiana Santos (fabianacamargo@bce.unb.br) on 2018-08-27T21:05:27Z No. of bitstreams: 1 2018_WanderleyGustavoNicácio.pdf: 30765952 bytes, checksum: 81e5701ccda6742875f7ac2cbcce6af7 (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-08-31T16:53:40Z (GMT) No. of bitstreams: 1 2018_WanderleyGustavoNicácio.pdf: 30765952 bytes, checksum: 81e5701ccda6742875f7ac2cbcce6af7 (MD5) / Made available in DSpace on 2018-08-31T16:53:41Z (GMT). No. of bitstreams: 1 2018_WanderleyGustavoNicácio.pdf: 30765952 bytes, checksum: 81e5701ccda6742875f7ac2cbcce6af7 (MD5) Previous issue date: 2018-08-27 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES). / Ao longo dos anos foram desenvolvidos novos sistemas de lajes com vazios moldados a partir de formas de plástico, com destaque para as lajes BubbleDeck (BD). Nestes sistemas, o conceito consiste em colocar formas de plástico reciclado oco entre duas malhas de armadura, no centro de uma laje de concreto. A laje BD é comumente associada ao sistema de lajes lisas, que tem como uma de suas preocupações do ponto de vista de dimensionamento a ruptura localizada por punção na ligação laje-pilar. Esta pesquisa avalia experimentalmente o comportamento à punção, num sistema de lajes lisas de concreto armado dos tipos BD e maciça, localizadas internamente à edificação e submetidas a carregamento simétrico. No total foram ensaiados 11 modelos com dimensões de 2500 x 2500 mm de comprimento base, altura nominal de 280 mm, pilares circulares centrados com dimensão de 300 mm de diâmetro e mesma taxa da armadura de flexão, variando-se: a utilização de pré-laje, a distribuição das armaduras de cisalhamento e sua respectiva forma de ancoragem. Os resultados obtidos com os ensaios possibilitaram avaliar comparativamente o comportamento dos modelos quanto aos deslocamentos verticais, deformação específica no concreto, no aço e na armadura de cisalhamento, carga última, fissuração, superfície e modo de ruptura. São apresentadas as previsões da capacidade última das ligações ensaiadas conforme as prescrições adaptadas das normas ACI 318 (2014), Eurocode 2 (2004) e ABNT NBR 6118 (2014), incluindo também as recomendações do fib Model Code 2010 (2012). De posse de todos resultados, foi proposta uma adequação da NBR 6118 (2014) para o caso de punção em lajes BD, de forma a apresentar previsões mais próximas dos resultados experimentais. Por fim, foi verificada a viabilidade da utilização do software FEMIX 4.0 para representar o comportamento de lajes BubbleDeck. / Various types of voided concrete slabs have been used throughout the years, especially the BubbleDeck slabs (BD). In these systems, the concept consists of placing forms of hollow plastic balls between the tensile and compressive reinforcement meshes, in the middle of the concrete slab. The BD slab is commonly associated with the flat slab system, which warns the designer about a punching shear failure at slab-column connections. This research experimentally evaluates the behavior in punching shear in systems of BD type flat slabs and solid slabs, simulating an inner slab-column connection of a building and submitted to symmetrical loading. In total, 11 models measuring 2500 x 2500 mm in length, nominal height of 280 mm, supported on centered circular column with a 300 mm diameter and the same flexural reinforcement ratio, varying the use of precast panel, the distribution of shear reinforcement and its anchorage. The results obtained from the experimental tests are comparatively shown with respect to the slabs vertical displacement, the concrete, flexural and shear reinforcement strains, ultimate loads, cracking patterns, surface and failure modes. Predictions of ultimate capacity of the tested connections are calculated according to the requirements of the ACI 318 (2014), Eurocode 2 (2004) and ABNT NBR 6118 (2014) standards, and the fib Model Code 2010 (2012). With these results, it was proposed an amendment to of NBR 6118 (2014) for the case of punching in BD slabs, in order to match the experimental results. Finally, the feasibility of the FEMIX 4.0 software to numerically simulate the behavior of BubbleDeck slab was verified.

Page generated in 0.0509 seconds