• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 75
  • 27
  • 6
  • 4
  • 1
  • 1
  • 1
  • Tagged with
  • 133
  • 133
  • 68
  • 65
  • 51
  • 33
  • 28
  • 26
  • 26
  • 21
  • 19
  • 17
  • 17
  • 16
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Avaliacao da eficacia do tratamento para mucosite oral induzida por cinco-fluoracil, com uso de laser de baixa potencia em diferentes comprimentos de onda

CUNHA, CATHARINE B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:26Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:26Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP; Faculdade de Odontologia, Universidade de Sao Paulo, Sao Paulo
72

Reparo ósseo em scaffolds de TI6AL4V sinterizados pela tecnologia de sinterização direta de metais a laser (DMLS) submetidos a tratamento de superfície associado à aplicação de ultrassom de baixa intensidade (LIPUS) / Bone repair in Ti6Al4V porous scaffolds processed by direct seletive laser melting submited to surface treatment associated low intensity pulsed ultrasound – (LIPUS)

Bastos, Jaqueline Silva [UNESP] 20 January 2016 (has links)
Submitted by Jaqueline Bastos (keca78@yahoo.com.br) on 2016-04-26T17:00:34Z No. of bitstreams: 1 TESE JAQUELINE S BASTOS - finalizando 180316.pdf: 13526973 bytes, checksum: d40891f9f50c56b18b4ee564f6453a39 (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-04-28T17:50:25Z (GMT) No. of bitstreams: 1 bastos_js_dr_guara.pdf: 13526973 bytes, checksum: d40891f9f50c56b18b4ee564f6453a39 (MD5) / Made available in DSpace on 2016-04-28T17:50:25Z (GMT). No. of bitstreams: 1 bastos_js_dr_guara.pdf: 13526973 bytes, checksum: d40891f9f50c56b18b4ee564f6453a39 (MD5) Previous issue date: 2016-01-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo desse estudo in vivo foi verificar a resposta óssea de scaffolds porosos revestidos processados pela técnica de Sinterização Direta de Metais a laser (DMLS) associado à terapia de ultrassom de baixa intensidade. Os scaffolds foram processados empregando a técnica DMLS e tratados termicamente a 1000°C por 24 horas. Três tipos de tratamento de superfície foram avaliados: Alcalino, biomimético e imobilização de alendronato de sódio. Para o tratamento alcalino, as amostras foram imersas na solução de NaOH (5M) a 60ºC por 24 horas. O tratamento biomimético consistiu na imersão dos scaffolds em solução SBF (SimulatedBodyFluid) enquanto a imobilização do alendronato foi realizada a partir da imersão dos scaffolds em uma solução formada por SBF e medicamento durante 5 dias. As superfícies dos scaffolds foram avaliadas para cada etapa empregando microscopia eletrônica de varredura (MEV) e análise por difração de raios-X. Os scaffolds foram implantados na tíbia direita de 85 ratos machos da raça wistar com idade média de 12 semanas. A microtomografia computadorizada (µCT) e análise histológica foram realizadas para avaliar o reparo ósseo no defeito. As micrografias das superfícies obtidas mostraram mudanças no aspecto da superfície e composição química de acordo com o tratamento. O tratamento biomimético promoveu o crescimento da apatita sobre a superfície enquanto a imobilização com alendronato suprimiu sua formação. As imagens obtidas na microtomografia mostraram elevado valor de densidade óssea para o último grupo. No entanto, análises histológicas mostraram a formação de cápsula fibrosa em torno dos scaffolds a qual foi minimizada usando ultrassom pulsado de baixa intensidade. No entanto, mais estudos precisam ser realizados para avaliar a influência da geometria dos scaffolds na incorporação de medicamentos. / The objective of this in vivo study was to verify the bone response of coated Ti6Al4V porous scaffolds processed by Direct Metal Laser Sintering (DMLS) technique associated to low intensity pulsed ultrasound therapy. Scaffolds were processed by using Direct Metal Laser Sintering technique (DMLS) and heat treated at 1000 °C for 24 hours. Three types of surface treatments were evaluated: alkaline, biomimetic and sodium alendronate immobilization. For alkaline treatment, samples were immersed in a NaOH (5M) solution at 60ºC for 24 hours. Biomimetic treatment consisted in the immersion of the scaffolds into Simulated Body Fluid solution while for sodium alendronato immobilization the scaffolds were immersed in the solution formed by SBF plus drug during 5 days. The scaffolds surfaces were evaluated after each step employing SEM (Scanning Electron Microscopy)and X-rays diffraction analysis(XRD). Scaffolds were implanted into right tibia of 85 male Wistar rats with average age of 12 weeks. X-rays micro-computed tomography (µCT) and histological analysis were carried out to evaluate the bone repair on the defect. Micrographs analysis showed that the aspect of the surfaces and chemical composition changed according treatment. Biomimetic treatment promoted the growth of the apatite on the surface; in contrast the immobilization of alendronate suppressed apatite formation. Micro CT images showed higher value of bone density for the last group. However, histological analysis showed the formation of encapsulation fibrous around the scaffolds. This formation was minimized by using low intensity pulsed ultrasound technique, however, more studies can be carried out to evaluate the influence of scaffolds geometry in the drug incorporation.
73

Avaliacao da eficacia do tratamento para mucosite oral induzida por cinco-fluoracil, com uso de laser de baixa potencia em diferentes comprimentos de onda

CUNHA, CATHARINE B. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:28:26Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:56:26Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP; Faculdade de Odontologia, Universidade de Sao Paulo, Sao Paulo
74

Utilização de laser de baixa intensidade, infravermelho, na prevenção e tratamento da mucosite oral em pacientes pediátricos com leucemia linfoblástica aguda / Use of infrared, low-intensity laser for prophylactic and treatment of oral mucositis in pediatric patients with acute lymphoblastic leukemia

Ana Rosa Mauricio 05 October 2007 (has links)
Este estudo randomizado, duplo-cego e controlado com placebo avaliou a eficácia do laser de baixa intensidade, infravermelho, na prevenção e tratamento da mucosite em pacientes pediátricos portadores de leucemia linfoblástica aguda (LLA) em uso do agente quimioterápico metotrexato em altas doses (MTX >1g/m2). Os pacientes foram distribuídos aleatoriamente em dois grupos: o grupo teste em que os pacientes receberam aplicação de laser profilático e o grupo controle com laser placebo. Os dois grupos receberam aplicação de laser nos dias D1, D2, D3. Realizada esta fase, os pacientes que desenvolveram mucosite oral tiveram acesso ao tratamento e aqueles que apresentaram mucosa normal foram orientados a retornar à consulta no 8º dia. Concomitante, foi solicitado exame hematológico prévio ao tratamento e no dia D8. Foi também mensurado o nível sérico do MTX 42 horas após a infusão da quimioterapia. Os resultados hematológicos prévios se mostraram satisfatórios e alguns apresentaram alterações no dia D8. No nosso estudo não foi possível comprovar se o nível sérico do MTX tem relação com toxicidade oral. A mucosite foi avaliada segundo a escala WHO e a avaliação da dor pré e pós-tratamento pelas escalas VAS, de faces e comportamental. Mucosite foi observada em 6 pacientes, 4 tratados com laser placebo e 2 tratados com laser profilático. Esta diferença não foi estatisticamente significante (P > 0.5). Os 6 pacientes desenvolveram grau 2 de mucosite oral. Média de laserterapia foi de 5.8 dias. Com relação à sintomatologia dolorosa 2 pacientes não apresentaram dor, 1 paciente apresentou dor moderada, nos outros a sintomatologia foi leve. Os resultados deste estudo demonstraram que o laser 780nm não foi eficaz na prevenção da mucosite oral mas constatamos o potencial efeito do laser terapêutico no controle da mucosite oral e da dor em pacientes pediátricos portadores LLA. / This randomized, double-blind, placebo-controlled study evaluated the efficacy of low intensity laser in the prevention and treatment of oral mucositis in pediatric patients with acute lymphoblastic leukemia undergoing chemotherapy with highdose methotrexate (MTX>1g/m2). The patients were divided into two groups: the test group, the patients who received prophylactic low-intensity laser, and the control group who received laser without radiation (sham laser). Nor the clinician neither the patients knew which type of laser was being used until the end of the trial. The patients of each group received laser application in the days D1, D2, D3. After that, the patients who developed oral mucositis were treated with low-intensity laser and those without oral mucositis were instructed to return on day 8 for clinical reevaluation. Concomitantly, patients were screening for previous hematological examination and in the day D8. The plasma level of MTX was measured at 42 hours starting the infusion. Hematological analyses revealed no abnormality and other with alterations. In this present study, there was no correlation between the plasma level MTX and oral toxicity. Mucositis was evaluated by the WHO scale and pain was measured by VAS, face scales and behavioral. Six patients developed oral mucositis and had grade 2 by WHO scale. There was no significant difference between laser group and the control group (P > 0.5). Average time of therapeutic laser was 5.8 days. Laser applications reduced oral pain. Low-intensity laser 780 nm wavelength showed no efficient method in the prevention of oral mucositis but produced some benefits in the control of the oral mucositis and pain in pediatric patients of LLA after chemotherapy.
75

Atividade Cicatrizante do Laser AlGaInP em Feridas Cutâneas Induzidas em Ratos Wistar / Acitivy algainp laser on healing of skin wounds in rats induced

SANTOS, Kelly Cristina Borges Tacon 14 March 2011 (has links)
Made available in DSpace on 2014-07-29T15:29:08Z (GMT). No. of bitstreams: 1 dissertacao kelly cristina borges tacon santos.pdf: 1732513 bytes, checksum: 5bf4b573e2a46462cc50c821b7b2fc7d (MD5) Previous issue date: 2011-03-14 / Objective: To analyze the healing activity AlGaInP laser in induced skin wounds in rats wistar. Materials and Methods: This is an experimental study, pre-clinical trial conducted in the room at the Center for Research and Toxic-pharmacological approaches. Were used for the experiment 54 Wistar rats divided into 3 groups of 18 animals and divided into 3 groups of 6 animals. The animals were weighed, tricotomiados anesthetized and then subjected to a surgical incision in the dorsal-neck of all animals using a punch of 1 cm (diameter). After 24 hours of surgery, we used the laser diode Aluminum Indium Gallium Phosphorus - AlGaInP (IBRAMED - Laserpulse) with a continuous power of 30 mW and wavelength (&#654;) of 660 nm for the treatment groups L3 and L6 (3 and 6J/cm2 + saline (0.9%) respectively and for the control group (CG) received only saline (0.9%). The animals (n = 6) for each group were euthanized at 5, 10 and 15th days after injury. The samples were embedded in paraffin, stained with hematoxylin-eosin and picrossírius. We observed the daily appearance of the wound during the healing process and noted in individual spreadsheet, by the same examiner. Data from histological evaluation were converted in quantitative variables by assigning scores: absent (0), mild (1-25%), moderate (25-50%) and severe (above 50%). For morphometric analysis, we used the program Image J. The count of the number of blood vessels was used for point counting planimetry. For analysis of collagen was used picrossírius staining and polarized light to scan images. The data were treated statistically by analysis of variance (ANOVA) and post-Tukey test. For the non - parametric variables we used the Kruskal - Wallis test. The significance level was set at (p<0.05). Results: There was a statistically significant difference in the contraction of the wound edge in L3 group compared to GC and L6 on the 10th day of the injury, indicating that the laser energy density 3J/cm2 acted positively in the healing process. During the histological assessment, we observed reduction of bleeding (p=0.007) L3 group compared to control and to the number of polymorphonuclear (p=0.045) treated groups L3 and L6 compared to control. Also on the 10th day there was also an increase in collagen content (p=0.003) L3 and L6 in the groups compared to control. On the 15th day was observed a significant increase in collagen content (p=0.034) of the L6 in the control group. Conclusion: The wound healing activity AlGaInP laser was evidenced by increased angiogenesis, decreasing inflammation and stimulation of fibroplasia. Thus it is assumed that the laser used in the study contributed positively tested in both phases (inflammatory and proliferative) to accelerate the healing process and also that the energy densities of three proposals 6J/cm2 and responded to the type of treatment proposed in this study. / Objetivo: Analisar a atividade cicatrizante do laser AlGaInP em feridas cutâneas induzidas em ratos wistar. Materiais e Métodos: Trata-se de um estudo experimental, pré-clínico, realizado na sala de experimentação do Núcleo de Estudos e Pesquisas Tóxico-farmacológicas. Foram utilizados para o experimento 54 ratos fêmeas linhagem Wistar distribuídos em 3 grupos de 18 animais e subdivididos em 3 grupos de 6 animais. Os animais foram pesados, tricotomiados, anestesiados e posteriormente submetidos a uma incisão cirúrgica em região dorso-cervical de todos os animais utilizando um punch de 1cm (diâmetro). Após 24 horas da cirurgia utilizou-se o laser diodo Alumínio Gálio Índio Fósforo - AlGaInP ( IBRAMED Laserpulse) com uma potência contínua de 30 mW e comprimento de onda (&#654;) de 660 nm para o tratamento dos grupos L3 e L6 (3 e 6J/cm2 + solução fisiológica (0,9%) respectivamente e para o grupo controle (GC) utilizou-se apenas solução fisiológica (0,9%). Os animais (n=6) de cada grupo foram eutanasiados no 5, 10 e 15° dias após a lesão. As amostras obtidas foram emblocadas em parafina, coradas com hematoxilina-eosina e picrossírius. Foi observado diariamente o aspecto da ferida durante o processo de cicatrização e anotado em planilha individual, sempre pelo mesmo examinador. Os dados da avaliação histológica obtidos foram transformados em variáveis quantitativas, pela atribuição de escore: ausente (0), discreto (1 a 25%), moderado (25 a 50%) e acentuado (acima de 50%). Para análise morfométrica, utilizou-se o programa Image J. A contagem do número de vasos sanguíneos utilizou-se a planimetria por contagem de pontos. Para análise do colágeno utilizou-se coloração picrossírius e luz polarizada para digitalizar as imagens. Os dados foram tratados estatisticamente pela análise de variância (ANOVA) e pós-teste de Tukey. Para as variáveis não paramétricas utilizou-se o teste Kruskal Wallis. O nível de significância foi fixado em p< 0,05. Resultados: Observou-se uma diferença estatística significativa na contração da borda da ferida no grupo L3 em relação aos grupos GC e L6 no 10º dia da lesão, indicando que o Laser na densidade de energia 3J/cm2 atuou de forma positiva no processo de cicatrização. Durante a avaliação histológica, observou-se diminuição da hemorragia (p=0,007) do grupo L3 em relação ao controle e também no número de polimorfonucleares (p=0,045) dos grupos tratados L3 e L6 em relação ao controle. Ainda no 10°dia observou-se também um aumento no conteúdo de colágeno (p=0,003) nos grupos L3 e L6 em relação ao controle. No 15° dia foi observado um aumento significativo no conteúdo de colágeno (p=0,034) do grupo L6 em relação ao grupo controle. Conclusão: A atividade cicatrizante do laser AlGaInP foi evidenciada pelo aumento da angiogênese, diminuição da inflamação e estímulo da fibroplasia. Dessa forma admite-se que o laser utilizado no estudo contribuiu de forma positiva em ambas as fases testadas (inflamatória e proliferativa) para acelerar o processo de cicatrização e também que as densidades de energia propostas 3 e 6 J/cm2 responderam ao tipo de tratamento proposto neste estudo.
76

Efeitos da estimulação ultra-sônica sobre a espermatogênese de ratos pré-púberes e adultos: estudo experimental / Effects of the stimulation ultrasonic about for spermatogenesis of rats prepubertal and adult: experimental study

Ruberval Farias da Silva 02 March 2007 (has links)
Esta investigação tem a finalidade estudar experimentalmente os efeitos do ultra-som pulsado de baixa intensidade sobre a espermatogênese de ratos pré-púberes e adultos. Foram utilizados 40 ratos machos da raça Wistar, sendo 20 pré-púberes e 20 adultos, os quais tiveram os testículos estimulados por 15 minutos durante 10 dias consecutivos. Cada grupo experimental constou de 10 animais pré-púberes ou adultos, estimulados com o ultra-som pulsado de baixa intensidade ou não estimulados. Administrou-se Colchicina, 6 horas antes do sacrifício dos animais com a finalidade de bloquear a divisão das células em metáfase para facilitar a avaliação do ciclo espermatogenético. Mediante morfometria estimou-se as áreas dos túbulos seminíferos e fez-se a avaliação dos estadios do ciclo espermatogenético quando foi constatado um aumento significativo das áreas dos túbulos seminíferos dos animais estimulados. O ciclo espermatogenético de ratos pré-púberes e adultos foi avaliado mediante contagens de associações celulares do ciclo nos estadios VII e VIII e XIV, correspondentes ao fim e início de cada ciclo. Houve aumento temporal do ciclo espermatogenético por apresentar maior número de associações com características dos estadios VIII significando acentuada maturidade de espermatozóides nos ratos pré-púberes estimulados. Os testículos dos animais adultos estimulados apresentaram aumento de peso em relação aos dos controles, exibindo uma diferença significativa. Nossos resultados são compatíveis com a hipótese de que o ultra-som pulsado de baixa intensidade estimula o aumento do peso dos testículos dos ratos adultos e das áreas dos túbulos seminíferos, bem como acelerando o ciclo espermatogenético em ratos pré-púberes. / This is an experimental study of the effects of low intensity pulsed ultrasound on the spermatogenesis of prepubertal and adult male rats. Forty male Wistar rats - twenty prepubertal and twenty adults -, whose testicles were stimulated for fifteen minutes for ten consecutive days were studied. Each experimental group was composed of ten prepubertal or adult animals, stimulated with low intensity pulsed ultrasound or not. Six hours before killing, the rats were given Colchicine to block the division of metaphasic cells, in order to facilitate the assessment of the spermatogenetic cycle. The area of the seminiferous tubule was done estimated by morphometry and the stages of spermatogenetic cycle were assessed, showing a significant increase of the areas of the seminiferous tubules of the stimulated animals. The spermiogenesis of prepubertal and adult rats was assessed through counts of cell associations in the stages VII and VIII and XIV, corresponding to the end and beginning of each cycle. There was a temporal increase in the spermatogenetic cycle due to a higher number of the associations with stage VIII characteristics, which means accentuated sperm cell maturity of the stimulated prepubertal rats. The testicles of the stimulated animals were weight increase regarding the of the control animals, showing a significant difference. Our results are compatible with the hypothesis that the low intensity pulsed ultrasound stimulates the increase of the testicle weight, the rats adults, and the area of the seminiferous tubules as well as accelerating the spermatogenetic cycle in rats prepubertal.
77

Estudo comparativo do efeito das fototerapias LED e LASER de baixa intensidade no tratamento da mucosite oral em pacientes submetidos à quimioterapia / Comparative study of the effects of LASER and LED phototherapies in the treatment of oral mucositis in patients submitted to chemotherapy

Ana Carolina Carneiro de Freitas 01 June 2012 (has links)
A mucosite oral é uma lesão induzida pelo tratamento quimioterápico, radioterápico ou pela associação de ambos. Esta consiste em uma inflamação da mucosa oral que pode gerar dor, interferir na qualidade de vida, predispor a infecções e gerar interrupções no tratamento do câncer. Devido a estes motivos, o seu tratamento se faz necessário. Há evidências científicas que comprovam que a terapia com LASER de baixa intensidade é uma forma de tratamento eficaz para estas lesões orais e, alguns autores, defendem que o LED representa uma alternativa ao LASER, sendo uma terapia mais barata e mais rápida que este. No entanto, poucas pesquisas foram realizadas com o LED e não há na literatura nenhum trabalho que compare clinicamente o efeito da terapia LED e LASER de baixa intensidade no tratamento das mucosites. Com isso, o objetivo desta pesquisa foi comparar o efeito das fototerapias LED e LASER no tratamento da mucosite oral induzida por quimioterapia. Quarenta pacientes com mucosite oral induzida por quimioterapia, foram divididos em dois grupos, onde um recebia o tratamento com LASER diodo (660nm, 40mW, 6J/cm2, 0,24J por ponto) e o outro com LED (630nm, 80mW, 0,24J/cm2, 0,24J por ponto) durante 10 dias consecutivos, excluindo os finais de semana. Os pontos anatômicos de aplicação eram os mesmos para ambas as fototerapias e foram distribuídos pelos lábios, comissuras, mucosa labial e jugal, palato mole e duro, língua e assoalho bucal. A cada consulta, antes da aplicação das fototerapias, foi realizada a avaliação do grau de mucosite por meio da escala da Organização Mundial da Saúde (OMS) e da dor através da Escala Visual Analógica (EVA). Após a realização das análises estatísticas, observou-se que o LED para os graus iniciais 1 e 2 de mucosite apresentou ação analgésica estatisticamente melhor do que a do LASER (p=0,012 e 0,022, respectivamente), mas seu efeito sobre a cicatrização das lesões de mucosite foi semelhante ao do LASER. Para o grau inicial 3 de mucosite, o LED promoveu uma melhor cicatrização (p=0,028) e uma ação analgésica semelhante a do LASER. Em conclusão, a fototerapia com LED mostrou-se mais eficaz que o LASER para a diminuição do grau de mucosite e do escore de dor nas condições do presente trabalho. / Patients submitted to chemotherapy and/or head and neck radiotherapy are usually affected by oral complications, especially oral mucositis and severe pain, which demands support therapy. Although the management of such oral complications by phototherapy with LASER (Laser Phototherapy - LPT) and with LEDs has been studied, the comparison between these therapies has not been studied yet. Thus, the aim of this study is to compare the effect of these two therapies against chemotherapy-induced oral mucositis (CIOM) and pain. Forty patients with CIOM were submitted to phototherapy according to 2 groups: G1, red low power LASER; G2, red LED. The treatment was done during 10 days. The LPT was done using an InGaAlP LASER (660nm/40mW/6Jcm-²/0,24J per point). The LED phototherapy was done using 0,24J per point/80mW/630nm. CIOM grade was assessed at each session in accordance to the World Health Organization (WHO). The patient self-assessed pain was measured by means of the visual analogue scale (VAS). The results showed that both treatments were effective, however, patients with initial mucositis grade 3, submitted to LED phototherapy presented significant decrease in the mean CIOM grades when compared with patients submitted to LASER phototherapy. In addition, LED showed better results in pain relief of patients with initial mucositis grade 1 and 2 (p=0,012 e 0,022, respectively) when compared with LASER therapy. In conclusion, phototherapy with LED is more effective than LPT on the management of CIOM which in turn would improve the patients quality of life.
78

Proliferação de células-tronco de polpa dental com o uso de laser de baixa potência: estudo in vitro / Proliferation of dental pulp stem cells using low intensity laser: in vitro study

Oliveira, Patrícia Yanne de 27 July 2017 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-08-21T18:31:15Z No. of bitstreams: 1 patriciayannedeoliveira.pdf: 1047015 bytes, checksum: 1a92b1ec7fc7cdc1e6d9f8551e6c4790 (MD5) / Rejected by Adriana Oliveira (adriana.oliveira@ufjf.edu.br), reason: Favor verificar metadata.dc.contributor.advisor2: Resende on 2017-08-24T12:05:18Z (GMT) / Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-08-24T12:09:35Z No. of bitstreams: 1 patriciayannedeoliveira.pdf: 1047015 bytes, checksum: 1a92b1ec7fc7cdc1e6d9f8551e6c4790 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-08-25T12:00:33Z (GMT) No. of bitstreams: 1 patriciayannedeoliveira.pdf: 1047015 bytes, checksum: 1a92b1ec7fc7cdc1e6d9f8551e6c4790 (MD5) / Made available in DSpace on 2017-08-25T12:00:33Z (GMT). No. of bitstreams: 1 patriciayannedeoliveira.pdf: 1047015 bytes, checksum: 1a92b1ec7fc7cdc1e6d9f8551e6c4790 (MD5) Previous issue date: 2017-07-27 / Objetivo: Neste estudo in vitro, avaliou-se a proliferação de células-tronco de polpa dentária (DPSCs) após a aplicação de laser de baixa intensidade. Métodos: A análise da proliferação de DPSCs cultivadas com DMEM e SFB a 10% foi realizada pelo ensaio de redução de MTT. Estas células foram irradiadas a cada 12 horas durante 72 horas ou de 24 em 24 horas durante 72 horas, com um laser Vermelho-InGaAlP (660nm, 30mW e 0,5 ou 1J/cm2) durante 16 ou 33 segundos. O melhor parâmetro dado pelo ensaio do MTT foi utilizado para analisar a diferenciação osteogênica e a viabilidade celular através do teste Trypan Blue. Para a análise estatística foi utilizado o teste ANOVA com nível de significância de 5% (p <0,05). Resultados: Através do MTT, foi possível observar que a menor dose de laser (0,5J /cm2) em aplicações as 0 e 48 horas obteve as melhores taxas de proliferação comparada a todos os outros grupos. Além disso, o laser de baixa intensidade não influenciou estatísticamente na diferenciação osteogênica e na viabilidade celular após a coloração com o vermelho de alizarina e o teste Trypan Blue no melhor parâmetro encontrato pelo MTT (0,5J/cm2). Conclusões: Ao analisar os resultados e considerando os parâmetros utilizados, podemos observar que o laser de baixa intensidade é uma ferramenta que favorece a proliferação de DPSCs. Finalmente, outros estudos devem ser realizados a fim de melhor definir os parâmetros para as aplicações de células-tronco. / Purpose: In this in vitro study, the proliferation of dental pulp stem cells (DPSCs) was evaluated after the application of low intensity laser. Methods: Analysis of the proliferation of DPSCs cultured with DMEM and 10% FBS was performed by the MTT reduction assay. These cells were irradiated every 12 hours for 72 hours or every 24 hours for 72 hours, with a RedInGaAlP laser (660nm, 30mW and 0.5 or 1J/cm2) for 16 or 33 seconds. The best parameter recorded by MTT was used to analyze the osteogenic differentiation and viability using the Trypan Blue test. For the statistical analysis the ANOVA test was used with significance level of 5% (p <0.05). Results: Through the MTT, it was possible to observe that the lowest dose of the laser (0.5J/cm2) in applications at 0 and 48 hours obtained the best proliferation rates then all the other groups. In addition, the low level laser did not appear to influence on the osteogenic differentiation nor the viability of the cells by the Trypan Blue test in the best parameter found by MTT (0.5J /cm2). Conclusions: When analyzing the results and considering the parameters used, we can observe that the low intensity laser is a tool that favors the proliferation of dental pulp stem cells. Finally, further studies should be carried out in order to better define parameters for stem cell applications.
79

Efeitos da atividade física aeróbia no complexo vásculo-alveolar no pulmão de ratos / Effects of the physical activity on the vasculo-alveolar complex of the rat\'s lung

Luciana Maria Bigaram Abrahão 18 September 2009 (has links)
O treinamento físico aeróbio crônico regular provoca importantes adaptações autonômicas e hemodinâmicas que influenciam o sistema cardiovascular. O presente trabalho teve como objetivo estudar os efeitos do treinamento físico aeróbio crônico, na citoarquitetura alveolar dos pulmões de ratos Wistar, sob os aspectos morfoquantitativo e funcional, bem como avaliar o efeito do treinamento na modulação da freqüência cardíaca (FC), da pressão arterial (PA), no perfil bioquímico (lactato, hemogasometria, glicemia e perfil lipídico: triglicérides, colesterol total, colesterol fracionado). Desta forma foram utilizados quinze ratos Wistar machos, com idade de 60 dias, que receberam ração própria para roedores e água sem restrição, e foram divididos em três grupos, sendo eles: Controle etário (CE, n=5), saudável sedentário (SS, n=5) e saudável treinado (ST, n=5). Após os registros de todos os parâmetros hemodinâmicos supracitados, os animais foram eutanasiados e fixados por perfusão com solução de formoldeído (4%), sendo o mesmo fixador instilado pela traquéia e perfundido via tronco pulmonar. Métodos estereológicos foram empregados para estimar o número total de aberturas alveolares pulmonares, bem como o volume do pulmão (Princípio de Cavalieri). A pressão arterial sistólica (PAS) foi 140,87 mmHg para o CE, 146,70 mmHg para o SS e 149,53 mmHg para o ST (p = 0,137) A pressão arterial diastólica (PAD) foi 115,83 mmHg para o CE, 107,00 mmHg para o SS e 105,39 mmHg para o ST (p = 0,0004). A pressão arterial média (PAM) foi 128,93 mmHg para o CE, 125,22 mmHg para o SS e 125,34 mmHg para o ST (p = 0,332). A FC foi 388,40 bpm para o CE, 379,83 bmp para o SS e 370,85 bpm para o ST (p = 0,381). O volume do pulmão foi 1,05 cm³ para o CE, 1,24 cm³ para o SS e 0,95 cm³ para o ST (p = 0,484). O número de aberturas alveolares pulmonares foi 21x106 para o CE, 25x106 para o SS e 38x106 para o ST (p = 0,02). Os resultados desse estudo sugerem que o treinamento físico aeróbio crônico em ratos promove um melhor estado hemodinâmico e um aumento no número de aberturas alveolares do pulmão dos animais exercitados. / The cardiovascular system is subject to important autonomic and haemodynamic adaptation by virtue of regular physical training. The aim of this study was to describe the effects of a treadmill physical training on the alveolar cytoarchitecture of the rat\'s lung from a morphoquantitative and functional point of view. Additional aims were to quantify the heart rate (HR), arterial pressure (AP), lactate, arterial blood gases, glucose, triglycerides, total and fractional cholesterol. For this purpose fifteen 60-day-old male Wistar rats were used. Animals were divided into three groups: age control (CE, n=5), sedentary (SS, n=5) and trained rats (ST, n=5). After recording the haemodynamic parameters, the animals were euthanised and perfusion-fixed with a 4 % formaldehyde solution, which was also intratracheally instillated. Design-based stereological methods were applied for estimating the total number of alveolar openings as well as the lung volume using Cavalieri\'s principle. The systolic arterial pressure (SAP) was 140.87 mmHg for the CE, 146.7 mmHg for the SS and 149.53 mmHg for the ST group (p=0.137). The diastolic arterial pressure (DAP) was 115.83 mmHg for the CE, 107 mmHg for the SS and 105.39 mmHg for the ST group (p=0.0004). The mean arterial pressure (MAP) was 128.93 mmHg for the CE, 125.22 mmHg for the SS and 125.34 mmHg for the ST group (p=0.332). HR was 388.4 bpm for the CE, 379.83 bmp for the SS and 370.85 bpm for the ST group (p=0.381). The lung volume was 1.05 cm³ for the CE, 1.24 cm³ for the SS and 0.95 cm³ for the ST group (p=0.484). The total number of alveolar openings alveolar was 21x106 for the CE, 25x106 for the SS and 38x106 for the ST group (p=0.02). The main findings of this research suggest that low-intensity treadmill physical training improves the haemodynamic parameters and increases the total number of alveolar openings of trained rats.
80

Développement de sources laser à fibres dopées ytterbium haute puissance, monofréquence et à bas bruit d'intensité / Development of high power low intensity noise singlefrequency ytterbium doped fiber lasers

Guiraud, Germain 21 July 2017 (has links)
Les sources laser à fibre, haute puissance et de faible largeur spectrale sont de plus en plus utiles pour des applications à la fois industrielle et scientifique. Cependant, le développement de ces sources est limité par les seuils d’apparition d’effets non-linéaires tels que la Diffusion Brillouin Stimulée (DBS) du fait d’un fort confinement de la lumière dans le coeur de la fibre. Un premier amplificateur en régime monofréquence de puissance moyenne égale à 50W a été développé à partir d’une diode laser signal de 50 mW. L’étude du bruit d’intensité sur cet amplificateur a montré que l’utilisation de fibres standards (diamètre de coeur < à 20μm) jusqu’à 50W est limitée par l’apparition du phénomène de DBS se traduisant par une dégradation du bruit d’intensité. Pour s’affranchir de ces effets non-linéaires, une solution réside sur l’utilisation de fibres à large aire modale (LMA) dont les diamètres des coeurs est égale à plusieurs dizaines de microns. Les fibres LMA présentent un recouvrement [coeur dopé / onde de pompe] optimisé conduisant à une réduction de la longueur du milieu à gain. Par cette stratégie de la diminution du confinement spatial du faisceau avec une diminution de la longueur d’interaction, le seuil d’apparition des effets non-linéaires est repoussé. Mais paradoxalement, cette stratégie va induire une nouvelle limitation non-linéaire, non plus en termes de puissance crête mais de puissance moyenne. En effet, les coeurs multimodaux des fibres LMA, couplés à une charge thermique par unité de longueur forte (pour une puissance de moyenne de sortie équivalente) vont induire l’apparition d’effets non-linéaires en puissance moyenne : les Instabilités Modales (IM) et la Dégradation Modale de la Fibre (DMF). Ce sont donc les stratégies usuelles utilisées pour repousser les effets non-linéaires qui ont conduit à l’avènement de ces nouveaux effets délétères. Un système d’asservissement du bruit d’intensité efficace (suppression > 30 dB) sur une bande passante d’1MHz permet de supprimer le bruit en excès des diodes de pompe. / High power, narrow linewidth fiber lasers are useful for both industrial and scientific applications. Nevertheless, nonlinear effects like Stimulated Brillouin Scattering (SBS) are main limitations of these laser sources due to high power in fiber core. A first amplifier in single-frequency operation with 50W of output power from a laser diode seeder of 50 mW was developed. Study of intensity noise on this amplifier developed with standard fiber (core diameter less than 20 μm) showed that SBS leads to a degradation of noise properties of the laser. The use of large mode area (LMA) fibers is a solution for suppressing nonlinear effects with core diameters bigger than several tens of microns. LMA fibers show an overlap between doped core and pump wave optimized leading to a reduction of gain medium length. This strategy permits to increase nonlinear effect threshold. Second step of high power amplifiers with LMA fibers allows to obtain 100W in single-frequency regime without DBS. LMA fiber used have a core diameter equals to 40μm. Power scaling from 100W to 200W highlights a new limiting non-linear effect: Fiber Modal Degradation (FMD). Indeed, multimodal cores of these fibers, coupled to high thermal load lead to non-linear effects like Modal Instabilities (IM) and FMD. FMD effect, first described by Ward et al in 2016, is a thermo-optic effect characterized by a beam quality degradation with power transfer from fundamental mode to high order modes. Furthermore, a decrease of output power, synonym of guidance loss of fundamental mode in gain medium is observed. Unlike well-known effect IM, this phenomenon doesn’t act like a threshold phenomenon. In fact, transitory regime in association with FMD is longer than IM caused by photodarkening dynamic. In our study, beam quality at the output of the fiber was degraded after several tens of hours at 200W. For understanding this effect, a photodarkening effect study both in continuous wave (CW) and pulsed regime was carried out. This study shows that for the first time a photodarkening and photobleaching equilibrium on high power amplifiers in pulsed regime. These thermo-induced effects threshold depends on thermal load and are different for both regimes: 120W for CW and 150W for pulsed regime. Finally, a study and a reduction of intensity noise based from a servo-loop were carried out on 100W amplifier. A 1MHz bandwidth with a 30 dB decrease of noise were demonstrated. These results allow to develop high power and low intensity noise lasers at industrial level”

Page generated in 0.0889 seconds