1

Energiåtervinning med frånluftsvärmepump i flerbostadshus : Simulering av ventilationsförluster och potentiell besparing, Spättan 1 / Energy recovery with exhaust air heat pump in apartment buildings : Simulation of ventilation losses and potential savings, Spättan 1

Holmqvist, Patrik, Fasth, Arvid January 2019 (has links)
Energi är ett ständigt aktuellt ämne, där byggnader står för en stor del av energianvändningen i Europa och Sverige. Samtidigt som energieffektiviseringar genomförs måste ett tillräckligt luftflöde bibehållas i byggnaden för att uppnå en komfortabel inomhusmiljö. Detta medför att en stor mängd energi cirkulerar i byggnadens ventilationssystem. Rapporten innehåller en simulering för att fastställa hur stor del denna är, kontra det totala energibehovet för ett flerbostadshus beläget i Kalmar, Sverige. Resultatet visar att ventilationen står för 35 % av det totala värmebehovet. Potentialen för återvinningsbar energi beräknades för att utvärdera hur mycket energi som kan sparas genom att installera en frånluftsvärmepump på ventilationssystemet. Simuleringar visar att vid ett godkänt minimumflöde på 0,35 l/s∙m2, skulle fastigheten kunna vara självförsörjande på värme under sommarmånaderna. Detta innebär att det går att återvinna ca 57 kWh/m2∙år, en reducering av energibehovet med 30 %. Vidare arbete skulle innebära fler mätningar på flöden, temperatur och fuktigheter.
2

Energianalys av luftbehandling

Bengtsson, Conny January 2011 (has links)
Elanvändningen till ventilation har ökat med 40 % sedan 1990 i Sverige. Ventilationen är en miljöbov enligt undersökningar som visar att elanvändningen till ventilationssystemens fläktar kan reduceras. Minskning av elförbrukningen kan t.ex. uppnås genom utbyte av fläktmotor till en EC-motor eller till en fläkt med bakåtböjda skovlar och direktdrift. Effektivieringsåtgärder kan ge en lägre elförbrukning på upptill 50 % i vissa applikationer. Ventilationsfläktarna i Sverige förbrukar 12,3 TWh per år. Idag har 175 000 ventilationsaggregat en för hög elanvändning och saknar värmeåtervinning. Enligt Energimyndigheten har området ventilation en stor besparingspotential eftersom energianvändningen till ventilation kan minska med 30 % (3,5 TWh), vilket ungefär motsvarar vindkraftsproduktionen i Sverige under ett år. Det analysverktyg som utvecklats i detta examensarbete är användarvänligt utformat och är tänkt som ett hjälpmedel vid utvärdering av funktion och effektivitet i luftbehandlingssystem. Verktyget analyserar mätdata från luftbehandlingssystemet och producerar nyckeltal som sedan jämförs mot givna nyckeltal och riktvärden, samt myndigheters gällande krav. Analysverktyget har provats på ett referensobjekt och fungerade som tänkt men får, i nuvarande utformning, anses vara en prototyp som kan vidareutvecklas. Viss utbildning krävs innan användning av analysverktyget sker, med hänsyn till elsäkerhet och mätnoggrannhet. Detta examensarbete avser vidare att kartlägga hur stor besparingspotential det finns för energieffektivisering av byggnaders ventilation samt att utveckla ett beräkningsverktyg för att kunna möta efterfrågan som troligtvis kommer att uppstå från fastighetsägare som vill spara energi. / Electricity consumption for ventilation has increased by 40% since 1990 in Sweden. Ventilation is an environmental villain since inquiries indicates that the electricity consumption for ventilation system fans can be much reduced. Reduction of electricity consumption for ventilation purposes can be achieved through e.g. the exchange of fan motors to EC motors or to fans with backward curved blades and direct drive. Such measures can provide reduced power consumption by up to 50 % in some applications. The ventilation fans in Sweden consume 12.3 TWh each year. Today Sweden has 175 000 ventilation systems with too high consumption of electricity and no heat recycling. According to the Swedish Energy Agency the ventilation sector has a large potential for savings and the energy consumption for ventilation could be lowered by 30 % (3,5 TWh), which roughly corresponds to the total annual wind power production in Sweden. The Analytical tool developed in this thesis work is designed to be user friendly and is thought to be an aid when evaluating functionality and efficiency in air treatment system. The tool analyzes data from measurements and produces key ratios which are then compared with given key ratios and standard guidelines. The Analysis tool was tested on one reference object and functioned as intended, but may at this stage be considered as a prototype that can be further developed. Specific training will be required before using the analysis tool with consideration to electrical safety and accuracy of measurement. This thesis work aims at evaluating the potential savings within air treatment systems in energy efficient buildings, and to develop a calculation tool to meet the demand that is likely to arise from property owners who want to save energy.
3

Energieffektivisering och dess påverkan på inomhusmiljön - En fallstudie av en kontorsbyggnad

Sandgren, Stefan January 2008 (has links)
Titel: Energieffektivisering och dess påverkan på inomhusmiljön – en fallstudie av en kontorsbyggnad. Syfte: Syftet är att undersöka och utreda resultatet av en energieffektivisering i en befintlig kontorsbyggnad samt att ta reda på hur brukarna upplever inomhusmiljön. Bakgrund: En byggnad, benämnd LU1, på Umeå universitet har i samband med en renovering genomgått en rad energieffektiviserande åtgärder. Ett nytt närvaro- och tryckstyrt luftbehandlingssystem som regleras ända ned på rumsnivå har installerats, en rad styr- och reglertekniska funktioner har implementerats men även en rad andra övriga åtgärder har vidtagits. Metod: Diverse mätningar har utförts i byggnaden tillsammans med en enkätundersökning med brukarna. Slutsats: Den specifika energianvändningen för uppvärmning, kyla och fastighetsel är efter energieffektiviseringen cirka 52 kWh/m2/år vilket går att jämföra med 126 kWh/m2/år som var genomsnittet för 123 kontorsbyggnader i en studie utförd av energimyndigheten. Resultat från både mätningar och enkätundersökning visar på att inomhusmiljön är mycket bra efter de åtgärder som utförts. Samtliga bestämmelser och krav har uppfyllts för inomhusmiljön i LU1 och enkätresultaten visar på mycket nöjda brukare. Den enda punkt där ett missnöje visas gäller sammanträdesrummen. / Title: Energy efficiency improvement and its impact on the indoor climate – A case study of an office building Purpose: The purpose is to examine and investigate the results of energy efficiency improvement in an existing office building and to find out how the working staff experience the indoor climate Background: A building, named LU1, at the University of Umeå has been through a series of energy efficiency measures as the building was renovated. A new presence- and pressure controlled air treatment system that adjusts all the way down to a room level has been installed as well as a series of automatic control functions. A series of other measures have also been taken. Method: Measurements have been made as well as a poll amongst the working staff. Conclusion: The specific energy use for heating, cooling and electricity used for building purposes is about 52 kWh/m2/year after the energy efficient measures were carried out, which compares to 126 kWh/m2/year which was the average for 123 office buildings in a study carried out by Energimyndigheten. The results from both the measurements and the poll however indicates that the indoors climate is very satisfactory after the measures carried out. All rules and regulations have been met for the indoors climate in LU1 and the results from the poll demonstrate that the working staff is very satisfied. The only aspect that indicates any dissatisfaction regards the conference rooms.