• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 135
  • 80
  • 49
  • 7
  • 4
  • 3
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 389
  • 389
  • 122
  • 64
  • 64
  • 62
  • 59
  • 57
  • 50
  • 45
  • 40
  • 33
  • 31
  • 30
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

Aplicação da quimiometria para caracterização química de combustíveis tipo MTR por fluorescência de raios X / Chemometrics application in fuel's MTR type chemical characterization by x-ray fluorescence

SILVA, CLAYTON P. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:35:27Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:05:40Z (GMT). No. of bitstreams: 0 / No Brasil e no mundo a tecnologia nuclear vem ocupando posição de destaque com diversas aplicações na indústria, geração de energia, meio ambiente e na medicina, melhorando a qualidade de exames e tratamentos, consequentemente, a vida das pessoas. O urânio é o principal elemento utilizado em instalações nucleares, servindo como material base desde a geração de eletricidade à fabricação de radiofármacos. Nos anos 50, em meio à guerra fria, a então recém-criada Agência Internacional de Energia Atômica se propôs a supervisionar instalações nucleares e incentivar a fabricação de combustíveis nucleares com baixo teor de urânio, conhecidos como combustíveis do tipo Material Test Reactor (MTR), fabricados inicialmente na forma de U3O8 e mais tarde o U3Si2, ambos dispersos em alumínio. A utilização desta tecnologia requer uma constante melhoria de todos os processos que envolvem a fabricação do MTR sujeita a diversos protocolos internacionais, os quais procuram garantir a confiabilidade desse combustível do ponto de vista prático e ambiental. Dentro desse contexto, o controle de impurezas, do ponto de vista da economia de nêutrons, afeta diretamente a qualidade de qualquer combustível nuclear, fazendo-se necessário um controle rigoroso. A literatura reporta procedimentos que, além de gerar resíduos, são demorados e dispendiosos, pois necessitam de curva de calibração univariada e materiais de referência. Assim, o objetivo deste trabalho é estabelecer e validar uma metodologia de análise química quantitativa não destrutiva, de baixo custo e tempo de análise, tal como, minimizar a geração de resíduo para a determinação multielementar dos maiores constituintes (Utotal e Si) e as impurezas (B, Mg, Al, Cr, Mn, Fe, Co, Ni, Cu, Zn, Mo, Cd e outros) presentes em U3O8 e U3Si2, atendendo as necessidades de reatores nucleares na qualificação de combustíveis nucleares do tipo MTR. Para tanto, foi aplicada a técnica de fluorescência de raios X que permite análises químicas rápidas e não destrutivas, além de não necessitar de tratamentos químicos prévios (dissolução, digestão e outros) na fase de preparação de amostras. Para as correções de efeitos espectrais e de matriz foram aplicados e avaliados os métodos de parâmetros fundamentais, de curva de calibração univariada e de calibração multivariada. Os resultados foram comparados por meios de testes estatísticos em conformidade com a norma ISO 17025 com os MRCs (123(1-7) e 124(1-7)) de U3O8 da New Brunswick Laboratory (NBL) e 16 amostras de U3Si2 cedidas pelo CCN do IPEN-CNEN-SP. A quimiometria demonstrou-se um método promissor para a determinação de maiores e menores constituintes em combustíveis nuclear a base de U3O8 e U3Si2, uma vez que a precisão e exatidão são estatisticamente iguais aos métodos de análises volumétrica, gravimétrica e ICP-OES. / Dissertação (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
292

Analise de integridade estrutural de tubos de geradores de vapor deteriorados por corrosao sob tensao pelo primario na regiao de transicao de expansao junto ao espelho

SILVEIRA, HELVECIO C.K. da 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:47:15Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:08:43Z (GMT). No. of bitstreams: 1 07971.pdf: 6425112 bytes, checksum: 2adaba2434371c9ca93a67fa4d783fb9 (MD5) / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN/CNEN-SP
293

Obtenção e caracterização de biocerâmicas porosas à base de fosfatos de cálcio processadas com a utilização de albumina / Obtention and characterization of porous bioceramics based calcium phosphate processing by using albumin

RIBEIRO, CHRISTIANE 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:54:26Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:09:29Z (GMT). No. of bitstreams: 1 12760.pdf: 9547849 bytes, checksum: 332801af390aaffe9d96d0f596a0e048 (MD5) / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN/CNEN-SP
294

Estudo do comportamento mecânico de cilindros de compósito epóxi/fibra de basalto em ensaios hidrostáticos / Study of mechanical behavior of epoxy/basalt fiber composite cylinders under hydrostatic tests

LAPENA, MAURO H. 23 November 2017 (has links)
Submitted by Pedro Silva Filho (pfsilva@ipen.br) on 2017-11-23T10:40:22Z No. of bitstreams: 0 / Made available in DSpace on 2017-11-23T10:40:22Z (GMT). No. of bitstreams: 0 / O objetivo deste trabalho foi estudar o comportamento mecânico de cilindros de compósito polimérico reforçado com fibras. Para isso, foram produzidos cilindros com extremidades abertas reforçados com fibra de basalto e fibra de vidro, utilizando a técnica de enrolamento filamentar (filament winding). Estes cilindros foram submetidos a ensaio hidrostático com carregamento circunferencial, ensaio de ruptura de anel (split disk test) e ensaio de resistência ao cisalhamento interlaminar (ILSS). Uma placa do compósito de fibra de basalto foi produzida por enrolamento filamentar, para caracterização por ensaio de resistência à tração. Todos cilindros submetidos ao ensaio hidrostático apresentaram fratura localizada em uma faixa de altura do cilindro, com extensas delaminações das camadas circunferenciais. Os compósitos epóxi/fibra de basalto superaram ou igualaram os de compósito epóxi/fibra de vidro nas comparações entre resultados dos valores das propriedades mecânicas avaliadas, nas porcentagens: resistência à tração aparente de ruptura de anel em 45% e 43% em resistência específica; ILSS, em 11%; resistência/tensão de membrana de ruptura no ensaio hidrostático, em 55%. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
295

Uso de ensaios de microesclerometria instrumentada no estudo das propriedades da austenita expandida. / Usage of instrumented microscratch tests for the study of expanded austenite properties.

Fernando Luís Sato 29 October 2014 (has links)
A excelente resistência à corrosão dos aços inoxidáveis austeníticos é a principal característica de sua ampla gama de aplicações nas mais diversas indústrias. Entretanto, as limitadas propriedades mecânicas da austenita, restringem o uso dessas ligas em sistemas que requeiram melhor desempenho tribológico sem prejuízo de sua resistência à corrosão. Métodos de endurecimento superficial convencionais tendem a formar precipitados que reduzem a disponibilidade dos elementos responsáveis pela passivação da liga, favorecendo a ação de agentes corrosivos. A descoberta de uma fase supersaturada em intersticiais denominada austenita expandida, ou Fase-S, tem lançado novas perspectivas sobre as opções de endurecimento superficial dos aços inoxidáveis austeníticos. Produzida por modernas técnicas baseadas no emprego do plasma, a austenita expandida apresenta elevadíssima dureza, da ordem de 14 GPa, sem prejuízo de sua resistência à corrosão, uma vez que não ocorre precipitação observável por microscopia ótica ou de varredura. Caracterizações mecânicas das camadas de austenita expandida por ensaios que simulem situações mais próximas da real condição de trabalho do material fornecem um conjunto de dados empíricos relevantes para a compreensão e modelagem de fenômenos tribológicos atuantes em um dado sistema mecânico. Nesse sentido, a microesclerometria instrumentada aparece com excelente opção de ferramenta para os estudos direcionados à Engenharia de Superfície. O presente trabalho apresenta os resultados de uma série de ensaios de microesclerometria instrumentada realizados em amostras de aço AISI 316 nitretadas a plasma por 20 h em forno de corrente contínua, utilizando a tecnologia de tela ativa, temperatura de 400 ºC e atmosfera formada por três partes de nitrogênio para cada parte de hidrogênio (3N2:1H2), resultando na formação de austenita expandida na superfície. Também são discutidos a caracterização das amostras, o baixo coeficiente de atrito (< 0,1) verificado experimentalmente e a ausência de falha adesiva da camada durante o ensaio. / One of the main reasons for the common utilization of austenitic stainless steels by various industries remains on their great corrosion resistance. On the other hand, the poor mechanical properties of austenite restrict the use of these alloys in systems which require better tribological performance without decreasing their corrosion resistance. Conventional case hardening techniques promote precipitate formation, reducing availability of passivation elements in metallic matrix, what can ease the action of corrosive external agents. The discovery of a carbon and/or nitrogen supersaturated phase, called expanded austenite or S-phase, brought new perspectives over case hardening options for austenitic stainless steels. Obtained by recent techniques based on plasma, expanded austenite has very high hardness, around 14 GPa, without reducing corrosion resistance, since no precipitate is noticeable by optical or scanning electronic microscopy. Using testing apparatus that simulates real work conditions, mechanical characterization of expanded austenite layers gives an important set of empirical data. These data are useful for comprehension and modeling of tribological phenomena occurring in a given mechanical system. In this way, instrumented microscratch test appears as an interesting option to be used in studies oriented to the Surface Engineering field. This work presents results from a series of instrumented microscratch tests performed over AISI 316 stainless steel samples with an expanded austenite layer. Plasma nitriding surface treatment was carried out during 20 h, in an active screen DC reactor under 400 ºC and atmosphere compounded by three parts of nitrogen for each part of hydrogen (3N2:1H2). The tribological behavior of the expanded austenite layer was characterized in a series of linear scratch tests. The results show that in the beginning of the scratch test the coefficient of friction was kept smaller than 0,1. When the first cracks appear the apparent coefficient of friction steadily increases, indicating that cracking of the nitrided layer lead to an increase of the coefficient of friction. Although the expanded austenite layer cracks, no adhesive failure was observed, the hardened layer being preserved during the whole scratch test.
296

Avaliação longitudinal da resistência de união de pinos de fibra de vidro à dentina cimentados com quatro agentes cimentantes por meio do teste de push-out

Rosalyn Chidiak Tawil 02 December 2008 (has links)
Avaliou-se a resistência de união do pino de fibra de vidro à dentina cimentado com quatro agentes cimentantes, por meio do teste push-out realizado após 24 horas e seis meses de armazenagem. Foram selecionados 80 dentes humanos uniradiculares, tratados endodonticamente e divididos aleatoriamente em quatro grupos (n=20), variando-se o tipo de cimento utilizado: grupo I: cimento de ionômero de vidro reforçado com resina (Fuji PlusTM, GC Corp., Tokyo, Japan); grupo II: cimento resinoso usando sistema adesivo convencional de 3 passos de aplicação (RelyX ARC + Scotchbond Multi-purpose, 3M ESPE, St Paul, MN, USA); grupo III: cimento resinoso usando sistema adesivo autocondicionante de 1 passo de aplicação (PanaviaTM F, Kuraray, Osaka, Japan); e grupo IV: cimento resinoso auto-adesivo (BisCemTM, Bisco Inc., Schaumburg, IL). Cada grupo foi subdividido em dois subgrupos (N=10) variando-se o tempo de armazenagem (24 horas e seis meses). O teste de push-out foi realizado com uma velocidade de 1,0 mm/min, e os resultados expressos em Mega Pascal (MPa). Após o teste de push-out, todos os espécimes foram observados em microscópio óptico de fluorescência (40x) e analisado o tipo de falha apresentado entre o complexo pino/cimento/dentina radicular. Os valores médios de resistência (MPa) foram submetidos ao teste ANOVA a dois critérios e de Tukey (p<0,005). A análise estatística mostrou: 1) Diferenças significativas na resistência de união entre os cimentos utilizados, sendo que a média total do cimento resinoso RelyXTM ARC + ScotchbondTM MultipurposeTM foi superior aos dos outros cimentos após 24 horas; 2) A resistência de união dos cimentos resinosos RelyXTM ARC + ScotchbondTM MultipurposeTM e PanaviaTM F foram superiores aos outros cimentos quando testados após seis meses de armazenagem e não houve diferença significativa entre eles; 3) Após seis meses de armazenagem, observou-se um aumento na resistência de união de todos os cimentos; 4) Na análise por terços, foi observado que tanto após 24 horas quanto após seis meses, o terço cervical teve uma maior resistência de união do que o terço médio e apical; 5) Foram observadas predominantemente falhas mistas, apresentado-se na maioria dos casos a combinação de falha adesiva na interface pino/cimento e na interface cimento/dentina para todos os grupos. Concluiu-se que a resistência de união aumentou após seis meses de armazenagem graças possivelmente à expansão higroscópica e aumento da retenção friccional. / The bond strength of a glass fiber post luted to dentin with four luting agents was evaluated using the push-out test, after 24-hours and six months of storage. Eighty human single-routed teeth was selected, endodontically treated and randomly divided into four groups (n=20), modifying the luting agent used: group I: resin modified glass-ionomer (Fuji PlusTM, GC Corp., Tokyo, Japan); group II: resin cement using total-etch, three step adhesive system (RelyX ARC + Scotchbond Multi-purpose, 3M ESPE, St Paul, MN, USA); group III: resin cement using self-etch one step adhesive system (PanaviaTM F, Kuraray, Osaka, Japan); and group IV: self-adhesive resin cement (BisCemTM, Bisco Inc., Schaumburg, IL). Each group was, then, subdivided into two subgroups (n=10) modifying the storage period (24-hours and six months). The push-out test was performed with a cross-speed of 1,0 mm/min, and the results expressed in Mega Pascal (MPa). After the test, all specimen interfaces were examined with the aid of a fluorescence optic microscope (40x) to dertemine the type of failure at the complex post/cement/dentin. The mean values of the bond strength (MPa) were analyzed with the two-way ANOVA and Tukey test (p<0,005). The statistical analysis showed: 1) Significant difference in the bond strength between the luting agents, in wich the mean total value of the resin cement RelyXTM ARC + ScotchbondTM MultipurposeTM was the highest after 24 hours; 2) The bond strength of the resin cement RelyXTM ARC + ScotchbondTM MultipurposeTM and PanaviaTM F were higher than the others luting agents when evaluated after six months, and there was no significant difference among both of them; 3) An increase in the bond strength of all luting agents after six months of storage in distilled water; 4) That the cervical third had a higher bond strength compared to the middle and apical thirds for all materials, during third analysis after 24-hours and six months of storage; 5) Predominantly, it was observed mixed failures, in the majority of the cases, with a combination of adhesive failure in the post/luting agent interface and in the luting agent/radicular dentin interface. Therefore, can be concluded that the bond strength of a glass fiber post luted to dentin with different luting agents can increase after six months of storage, possibly contributed by hygroscopic expansion and the increase of the frictional retention.
297

Avaliação histológica do capeamento pulpar direto com sericina de seda em ratos: um estudo preliminar / Histologic evaluation of direct pulp capping with silk sericin in mice: a preliminary study

Hartmann, Giovani Ceron 18 January 2018 (has links)
Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2018-04-20T13:11:28Z No. of bitstreams: 2 Giovani _Hartmann2018.pdf: 1083042 bytes, checksum: 4c6c31040314a6b8b1914db7eec998ac (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-04-20T13:11:28Z (GMT). No. of bitstreams: 2 Giovani _Hartmann2018.pdf: 1083042 bytes, checksum: 4c6c31040314a6b8b1914db7eec998ac (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-01-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / This study analyzed sericin as a potential biomaterial in contact with dentin pulp, histologically comparing its response to direct pulp capping with calcium hydroxide. These are the first morphological and functional data derived from application of this protein directly on pulp exposure. 20 maxillary first molars from Wistar male mice were used, with 60 days of age, between 200 and 300 grams, which were divided in 4 groups (n=5): G1 and G3, controls, capped with calcium hydroxide in 7 and 30 days, respectively; G2 and G4, capped with sericin in 7 and 30 days, respectively. Circular cavities were prepared for pulp exposure, where capping materials were applied, being posteriorly restored with glass ionomer cement. At the end of the groups period, animals were euthanized and molars were histologically processed for analysis in light microscopy to evaluate presence of necrosis in pulp tissue, inflammatory cells infiltration and tertiary dentin formation. After 7 days, there was less necrosis and inflammatory cells infiltration in G1 when compared to G2 (p=0.007 and p=0.008, respectively). After 30 days, a sample of G3 induced tertiary dentin formation and G4 showed decrease in inflammation (p=0.041) compared to G2. Among the determined experiment conditions, it was concluded that sericin did not present to be viable to treatment as it did not induce tertiary dentin formation, although, its contact with pulp tissue has shown improve in inflammatory response during the treatment and new cells proliferation. / Este estudo analisou a sericina como potencial biomaterial em contato com a polpa dental comparando histologicamente sua resposta ao capeamento pulpar direto com hidróxido de cálcio. Estes são os primeiros dados morfológicos e funcionais procedentes da aplicação desta proteína diretamente sobre a exposição da polpa. Foram utilizados 20 primeiros molares superiores de ratos Wistar machos, com 60 dias de idade entre 200 e 300 gramas, os quais foram divididos em 4 grupos (n=5): G1 e G3, controles, capeados com hidróxido de cálcio em 7 e 30 dias, respectivamente; G2 e G4, capeados com sericina em 7 e 30 dias, respectivamente. Cavidades circulares foram preparadas para exposição pulpar, onde foram aplicados os materiais capeadores, sendo posteriormente restauradas com cimento de ionômero de vidro. Transcorridos os tempos dos grupos, os animais foram eutanasiados e os molares foram processados histologicamente para análise em microscopia de luz para avaliar presença de necrose no tecido pulpar, infiltração de células inflamatórias e formação de dentina terciária. Aos 7 dias, a necrose e a infiltração de células inflamatórias foram menores em G1 quando comparado ao G2 (p=0,007 e p=0,008, respectivamente). Aos 30 dias, uma amostra do G3 induziu formação de dentina terciária e G4 apresentou diminuição de inflamação (p=0,041) em relação ao G2. Dentro das determinadas condições experimentais, concluiu-se que a sericina não se mostrou viável ao tratamento por não induzir formação de dentina terciária, entretanto, seu contato com o tecido pulpar demonstrou melhora na resposta inflamatória ao longo do tratamento e proliferação de novas células.
298

Influência do operador e do reanimador manual na manobra de hiperinsuflação manual: estudo em simulador do sistema respiratório / Influences of operator and manual resuscitator on manual hyperinflation maneuver. A lung model study

Tatiana de Arruda Ortiz 19 December 2008 (has links)
Introdução: A hiperinsuflação manual (HM) é uma técnica comum para facilitar a remoção de secreção traqueal de pacientes em UTI, e teoricamente, deveria ser realizada com uma insuflação lenta. Muitos fisioterapeutas não realizam a manobra com a insuflação lenta e os reanimadores manuais (RM) fabricados no Brasil possuem válvula de alívio de pressão, que não pode ser fechada na grande maioria desses dispositivos. Objetivos: Avaliar, em modelo mecânico, a influência da manobra de HM no volume corrente, picos de fluxo inspiratório e expiratório, e pressões alveolar e proximal por oito fisioterapeutas brasileiros, utilizando dois tipos de RM (com e sem válvula reguladora de pressão), de acordo com duas situações [conforme a prática clínica (PC) e após orientação de realizar a HM com a insuflação lenta, chamada de recomendada pela literatura (RL)], e em três cenários clínicos simulados (paciente normal, restritivo e obstrutivo). Resultados: Seis dos 8 fisioterapeutas realizaram a técnica com mais de duas insuflações; as pressões proximais geradas na situação RL foram menores devido aos menores picos de fluxo inspiratório. Os valores de pressões alveolares foram menores que 42,5 cmH2O (mediana = 13,9; intervalo interquartil:10,2-20,3) mesmo com altas pressões proximais (máximo 96,6 cmH2O, mediana 31,4; 19,2-44,8). Os volumes correntes foram menores do que os encontrados na literatura pesquisada (mediana = 514mL; 410-641). Os picos de fluxo inspiratórios (1,32; 0,92- 1,80) foram maiores que os expiratórios (0,88; 0,54-1,13) em quase todas as medidas. O pico de fluxo expiratório se correlacionou com o volume corrente: em cada cenário, os menores picos de fluxo expiratórios estavam correlacionados com baixos volumes correntes. Pressões, volumes e fluxos foram mais baixos com o RM com válvula reguladora de pressão. Conclusão: A manobra de HM foi realizada de forma diferente da preconizada na literatura; o RM com válvula reguladora de pressão gerou menores volumes, pressões e fluxos na maior parte dos cenários; as pressões proximais geradas não determinam, necessariamente, risco para o paciente, pois as pressões alveolares se mantiveram baixas / Background: Manual hyperinflation (MH) is a common technique used for removing pulmonary secretions in ICU and theoretically should be performed with a slow inflation. Many Brazilian respiratory therapists do not perform the maneuver with a slow inflation and manual resuscitators (MR) made in Brazil have pressure relief valve (PRV) which in many of them cannot be closed to perform MH. Objectives: evaluate, in a lung model, the influence on tidal volume, inspiratory and expiratory peak flow, proximal and alveolar pressures of MH performed by eight Brazilian respiratory therapists using two types of MR (with and without pressure relief valve), in two manners [like clinical practice (CP) and after orientation to perform MH with a slow inflation, named literature recommended (LR)] and in three clinical simulated scenarios (normal, restrictive and obstructive patient). Results: Six of 8 respiratory therapists performed MH with two or more inflation. After instruction proximal pressure generated was lower because of the slower inspiratory peak flow. The alveolar pressure values were lesser than 42.5 cmH2O (median = 13.9; interquartile range: 10.2-20.3), despite of high proximal pressure (max 96.6 cmH2O, median 31.4; 19.2-44.8). Inspiratory tidal volume were smaller than other reports (median=514mL; 410-641). Inspiratory peak flow (1.32; 0.92- 1.80) were higher than expiratory (0.88; 0.54-1.13) in almost all measurement. Expiratory peak flow was correlated with tidal volume: for each scenario, the low expiratory peak flow was mainly generated by small tidal volume. Pressures, volumes and flows were lower with MR that uses PRV. Conclusion: In this small sample of respiratory therapists, MH was done different that literature recommends; MR whit pressure limiting system generate lower tidal volume, pressures and peak pressures in most scenarios; proximal pressure generated not determine, necessarily, risk for patient, because alveolar pressure was maintained low
299

"Viscoelasticidade em função dos modos de fotoativação de compósitos" / Viscoelasticity as a function of fotoactivation mode

Milton Lazaro Filho 28 September 2004 (has links)
O escoamento viscoelástico pode contribuir ao alívio da tensão gerada durante a polimerização de compósitos aderidos em cavidades. O objetivo do estudo foi verificar a influência de dois modos de fotoativação contínua com diferentes intensidades (1000 mW/cm 2 e 250 mW/cm 2 ) e mesma densidade de energia final (24 J/cm 2 ) sobre propriedades viscoelásticas de dois compósitos comerciais (Filtek A110 e Herculite XRV) após a cura. Os parâmetros viscoelásticos avaliados foram: E’ (módulo de ar-mazenamento), tand (fator de perda) e as constantes reológicas t (tempo de relaxa-mento) e h (viscosidade).. Espécimes (50 x4 x 2 mm), de cada material em cada condição de fortoativação, (total de 51) foram confeccionados à temperatura ambiente e armazenados por 7 dias a 37 o C e submetidos então, a análise dinâmico-mecânica em aparelho DMA 242 (NETZSCH): varreduras de freqüência (50, 20, 10, 5, 2, 1 e 0,1 Hz) em ensaios isotérmicos (25 O C, 37 O C, 50 O C, 70 O C, 80 O C, 90 O C e Tg) em modo flexural (três pontos). Determinou-se também, a temperatura de transição vítrea (Tg). Os resultados de E’ e tand obtidos entre os 3 e os 7 minutos a cada temperatura permitiram a obtenção do módulo complexo E*. A aplicação do princípio de transposição tempo-temperatura de Williams-Landel-Ferry (TTS), resultou na curva mestra a 37 o C de E*(w). A aplicação de algoritmo de Laplace (RSI Orchestrator – Rheometrics), permitiu a obtenção da curva-mestra na mesma temperatura de E*(t). Através da aplicação do modelo matemático de Maxwell discretizado (n=10), obteve-se o espectro de relaxamento, que permitiu a obtenção de t e h de cada ma-terial em cada condição de fotoativação. Foi determinado também, em espécimes especialmente confeccionados para estas finalidades (n=3), o grau de conversão (GC) (análise de FTIR) e micro-dureza Knoop (KHN). Ambas propriedades foram analisadas antes (temperatura ambiente) e depois de tratamento térmico (aquecimento das amostras por 10 minutos a 110 o C). Os resultados do estudo permitiram concluir que: 1) Compósitos ativados com maior intensidade de luz produzem espécimes com menor t e h; 2) E’ e tand são significantemente afetados pelo aumento da intensidade da luz ativadora, diminuindo para Filtek A110 e aumentando para Hercu-lite XRV; 3) A Tg diminui com o aumento da intensidade para Filtek A110 e permanece inalterada para Herculite XRV; 4) Para Filtek A110, GC e KHN dos espécimes curados à temperatura ambiente não mudou com o aumento da intensidade, en-quanto que para Herculite XRV diminuiu; 5) GC e KHN melhoraram para Filtek A110 com o tratamento térmico adicional; para Herculite XRV, apenas KHN melhorou com o tratamento térmico, mas não o GC. / Viscoelastic flow may contribute to the stress relief generated during composites po-lymerization adhered in cavities. The aim of this study was to verify how two modes of continuous photoactivation with different intensities (1000 mW/cm 2 and 250 mW/cm 2 ) and same density of the final energy (24 J/cm 2 ) affect viscoelastic properties after cure of two commercial composites (Filtek A110 and Herculite XRV). The evaluated viscoelastic parameters were: E’ (storage modulus), tand (loss factor) and rheologic constraints t (relaxation time) and h (viscosity). Specimens (50 x4 x 2 mm), of each material at each photoactivation mode (totaled 51) were built at room tem-perature and have been stored for 7 days at 37 o C to undergo the dynamic-mechanical analysis in DMA 242 (Netzsch) equipment. Frequency sweep was made (50, 20, 10, 5, 2, 1 and 0,1 Hz) in each of the isothermic testing (25 O C, 37 O C, 50 O C, 70 O C, 80 O C, 90 O C and Tg) in flexural test (3 points). It was also determined glass transition temperature (Tg). The results of E’ and tand obtained between 3 and 7 min-utes at each temperature allowed to obtain complex modulus E*. The application of time-temperature switch principle of Williams-Landel-Ferry (TTS) ended up in master-curve of E*(w) at 37 o C. The use of the Laplace algorithm (RSI Orchestrator – Rheometrics) allowed to obtain the master curve (at same temperature) of E*(t). By means of the using of discretized Maxwell’s mathematical model (n=10), relaxation spectrum was obtained, which resulted in t and h of each of the materials in each of the photoactivation conditions. Degree of conversion (DC) (FTIR analysis) and Knoop microhardness (KHN) were also determined in specially made specimens for these purposes (n=3). Both properties were analyzed before (room temperature) and after thermal treatment (heating of the specimens for 10 minutes at 110 o C). The results of the study allowed to conclude that: 1) Composites activated with higher intensity yield lower t and h specimens; 2) E’ and tand are meaningfully affected by the increase of the activating light intensity, decreasing for Filtek A110 and increasing for Herculite XRV; 3) Tg decreases with the intensity increase for Filtek A110 and remains un-changed for Herculite XRV; 4) For Filtek A110, DC and KHN of the cured specimens at room temperature, remained unchanged with the intensity increase, while for Her-culite XRV they decreased; 5) DC and KHN raised for Filtek A110 with additional thermal treatment – for Herculite XRV, only KHN improved with thermal treatment, but there were no changes for DC.
300

O efeito do uso de fitoterápicos e da própolis nas propriedades físico-químicas, antimicrobiana e biocompatibilidade do MTA / The effect of the use of phytotherapics and propolis in physicochemical properties, antimicrobial and biocompatibility of MTA

Bruno Cavalini Cavenago 31 March 2015 (has links)
O objetivo deste estudo foi avaliar as propriedades físico-químicas, antimicrobianas e biocompatibilidade do MTA branco manipulado com extratos aquoso e/ou em propilenoglicol da Arctium lappa L., Casearia sylvestris Sw. e própolis. Dentre os testes físico-químicos foram avaliados o tempo de presa, escoamento, pH, liberação de íons cálcio e alteração volumétrica. Para verificar o efeito antimicrobiano foram aplicadas as metodologias do contato direto (Enterococcus faecalis e a Cândida albicans) e da descontaminação dentinária, empregando a microscopia confocal de varredura laser para verificar a viabilidade de Enterococcus faecalis. Para a avaliação da biocompatibilidade, 162 ratos Wistar foram utilizados, onde cada animal recebeu dois implantes subcutâneos e um alveolar. Após os períodos experimentais de 15, 30 e 60 dias foram realizadas análises microtomográfica, histológica descritiva e histomorfométrica. Adicionalmente amostras do tecido alveolar foram processadas para dosagem das citocinas TNF-&#x3B1; e IL-10 por meio do ensaio imunoenzimático (ELISA). Os dados obtidos foram analisados estatisticamente com os testes ANOVA e Tukey ou Kruskal-Wallis e Dunn. Os resultados revelaram que a variação do veículo associado ao MTA aumentou significativamente o tempo de presa, no entanto, não houve influência na alteração volumétrica (P>0,05) e na capacidade do cimento em manter o meio alcalino e liberar íons cálcio. Os cimentos manipulados com extratos em propilenoglicol apresentaram maior escoamento (P<0,05). Apenas o extrato da própolis agregou ao MTA efeito contra o Enterococcus faecalis após 24 e 48 horas (descontaminação dentinária e contato direto respectivamente) e contra a Cândida albicans após 10 horas (P<0,05). De acordo com as avaliações histológica e histomorfométrica dos implantes em tecidos subcutâneo e alveolar não foi constatada diferença significativa entre os grupos experimentais quando comparados com o grupo no qual o MTA foi manipulado com água destilada. Segundo a análise microtomográfica e a expressão das citocinas TNF-&#x3B1; e IL-10 houve similaridade (P>0,05) entre todos os grupos. Apesar de ter alterado algumas propriedades físico-químicas, o extrato da própolis potencializou o efeito antimicrobiano do MTA sem, contudo, alterar sua biocompatibilidade. / The aim of this study was to evaluate the physicochemical, antimicrobial properties and biocompatibility of white MTA mixed with aqueous or propylene glycol extracts of Arctium lappa L., Casearia sylvestris Sw. and propolis. Among physicochemical tests were evaluated the setting time, flowability, pH, ion calcium release and volumetric change. To verify the antimicrobial effects were applied the methods of direct contact (Enterococcus faecalis and Candida albicans) and dentin decontamination by using the confocal laser scanning microscopy to verify the Enterococcus faecalis viability. To evaluate the biocompatibility were used 162 Wistar rats. Each animal received one alveolar and two subcutaneous implants. After the experimental periods of 15, 30 and 60 days were performed the microtomography, histological description and histomorphometric analyses. Additionally alveolar tissue samples were processed for the measurement of TNF-&#x3B1; e IL-10 cytokines by enzyme-linked immunosorbent assay (ELISA). The data were statistically analyzed by the ANOVA and Tukey or KruskalWallis and Dunns tests. The results revealed that the variation of the vehicle associated to MTA significantly increased its setting time, however did not influence the volumetric change (P>0,05) and the cement\'s ability to maintain the alkaline medium and ion calcium release. Cements mixed with propylene glycol extracts showed higher flowability (P<0,05). Only propolis extract added to MTA the effect against E. faecalis after 24 and 48 hours (dentin decontamination and direct contact respectively) and against Candida albicans after 10 hours (P<0,05). According to the histological and histomorphometric evaluation of the implants in subcutaneous and alveolar tissue was not observed significant differences between the experimental groups in comparison to the reference group (MTA was mixed with distilled water). The microtomography analysis and expression of TNF-&#x3B1; and IL-10 showed that the groups were similar (P>0,05). Although the propolis extract modified some physicochemical properties of MTA it is potentiated the antimicrobial effect and did not influence the biocompatibility.

Page generated in 0.0492 seconds