• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 5
  • 2
  • 1
  • Tagged with
  • 15
  • 7
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

ValidaÃÃo de metodologia de determinaÃÃo de hidrocabonetos policÃclicos aromÃticos em Ãguas de produÃÃo por microextraÃÃo em fase sÃlida. / Validation of determinations methods of PAHs in produced water by solid phase microextraction

Pedro Hermano Menezes de Vasconcelos 05 April 2013 (has links)
Conselho Nacional de Desenvolvimento CientÃfico e TecnolÃgico / O descarte de Ãgua de produÃÃo em oceanos à um dos grandes problemas ambientais enfrentados pela indÃstria de petrÃleo e pela populaÃÃo, uma vez que esses efluentes possuem compostos nocivos à saÃde. Dentre estes compostos destacam-se os hidrocarbonetos policÃclicos aromÃticos (HPAs), compostos orgÃnicos caracterizados por apresentarem dois ou mais anÃis aromÃticos conjugados. Neste trabalho utilizou-se um planejamento fatorial para avaliar o efeito de alguns parÃmetros na extraÃÃo de HPAs em amostras de Ãgua de produÃÃo por microextraÃÃo em fase sÃlida (MEFS) e posterior anÃlise por cromatografia gasosa acoplada a um espectrÃmetro de massas (CGMS). Verificou-se que a tÃcnica favorece a prÃ-concentraÃÃo de HPAs em amostras e que os parÃmetros estudados (temperatura, concentraÃÃo de HPA, forÃa iÃnica, tempo de exposiÃÃo à fibra) influenciam de forma significante na quantidade de HPA extraÃda, sendo que o efeito de cada fator depende das estruturas dos HPAs. A anÃlise quantitativa e qualitativa por CGMS foi realizada utilizando a tÃcnica de fragmentos distintos em seus espectros de massas. Foram analisadas quatro amostras de Ãgua de produÃÃo, utilizando-se o mÃtodo de padrÃo interno. Realizou-se a validaÃÃo da metodologia, atravÃs de testes de precisÃo, linearidade, limites de detecÃÃo e quantificaÃÃo, e exatidÃo. A metodologia proposta mostrou-se eficiente visto que apresentou boa reprodutibilidade, linearidade satisfatÃria (os coeficientes de correlaÃÃo obtidos ficaram entre 0,9849 e 0,9999), valores de LD e LQ compatÃveis aos da literatura, e uma exatidÃo adequada na faixa de concentraÃÃo avaliada (valores de recuperaÃÃo variaram entre 84,23 e 148,52 %). O diferencial da metodologia foi ter conseguido analisar os HPAs presentes nas amostras que possuÃam matrizes bastante complexas sem a necessidade de qualquer prÃ-tratamento das mesmas. Os HPAs de menores massas molar foram, em geral, os majoritÃrios nas amostras de Ãguas investigadas. A quantidade total de HPA presente nas quatro amostras variou de 30,41 a 170,41 Âg L-1. Os valores das constantes de distribuiÃÃo calculados indicam que os HPAs de maiores massas molares apresentaram maior afinidade pela fibra de polidimetil-siloxano. / The disposal of water from oil production in the oceans is one of the major environmental problems facing the oil industry and the population, since these compounds have harmful effluents health. Among these compounds, the polycyclic aromatic hydrocarbons (PAHs) stand out. These substances are organic compounds characterized by presenting two or more conjugated aromatic rings. This study evaluated the effect of some parameters on the extraction of PAHs by SPME and subsequent analysis by GCMS using 24 factorial design to optimize the experiments, followed by the analysis of water samples from oil production. It has been found that the technique pre-concentrated samples and the parameters (temperature, PAH concentration, ionic strength, exposure time of the fiber) influence significantly on the amount of PAH extracted, and the effect of each factor depends on the structures of PAHs. The quantitative and qualitative analysis by GCMS was conducted using the technique of distinct fragments in their mass spectra. Four samples were analyzed for water production, using the internal standard method. Conducted to validate the methodology through testing precision, linearity, limits of detection and quantification, and accuracy. The proposed method was efficient, as it showed good reproducibility, linearity satisfactory (correlation coefficients were obtained between 0.9849 and 0.9999), values of LD and LQ compatible with the literature, and an accuracy in the proper concentration range evaluated (recovery values ranged between 84.23 and 148.52%). The factor innovative of the methodology have been able to analyze the PAHs in the samples had very complex arrays without the need for any pretreatment thereof. PAHs of lower molecular masses were, in general, the majority of water in the samples investigated. The total amount of PAH present in all four samples ranged from 30.41 to 170.41 g L-1. The values of the constants calculated distribution indicate that PAHs of higher molecular weights had higher affinity for the polydimethylsiloxane fiber.
12

ETS1 AND ETS2 ROLE IN RAS ONCOGENIC TRANSFORMATION IN MOUSE EMBRYONIC FIBROBLASTS

Kabbout, Mohamed Nazih 03 September 2010 (has links)
No description available.
13

ValidaÃÃo e determinaÃÃo de carbofurano e carbaril em plasma sanguÃneo de agricultores do perÃmetro irrigado do baixo Jaguaribe-CE por MEFS-HS/CG-EM / Validation and determination of carbofuran and carbaryl in blood plasma farmers of irrigated perimeter of Jaguaribe low-CE by SPME-HS / GC-MS

Francisco Thiago Correia de Souza 27 June 2014 (has links)
A presenÃa dos agrotÃxicos à cada vez mais preocupante no Brasil visto que entre 2007 e 2012, o volume de defensivos (considerando apenas o princÃpio ativo) aplicado nas lavouras cresceu 14 %. O uso descontrolado desses compostos tem oferecido riscos a trabalhadores e moradores das regiÃes do agronegÃcio. Uma pesquisa realizada por um grupo da Universidade Federal do CearÃ, mostrou que em 23 amostras de Ãgua da regiÃo do perÃmetro irrigado do baixo Jaguaribe, coletadas em diferentes localidades e analisadas por cromatografia lÃquida, todas apresentaram a presenÃa de algum agrotÃxico, destacando-se o carbaril e o carbofurano como os mais detectados. Um estudo constatou anormalidades cromossÃmicas em cÃlulas da medula Ãssea de indivÃduos expostos a pesticidas na regiÃo, o que reforÃa a necessidade de desenvolvimento de mÃtodos bioanalÃticos capazes de detectar pesticidas em amostras biolÃgicas, para que essa exposiÃÃo possa ser monitorada pelas autoridades competentes. Baseado nisso um mÃtodo foi desenvolvido para anÃlise de carbaril e carbofurano, usando um cromatÃgrafo a gÃs equipado com detector de massas, em que foi monitorado o sinal analÃtico do agrotÃxico e de seus respectivos produtos de degradaÃÃo tÃrmica, degradaÃÃo essa ocorrida injetor do cromatÃgrafo. Um estudo para determinaÃÃo da melhor velocidade linear para o mÃtodo foi realizado com a construÃÃo do diagrama de Van Deemter, sendo determinada como Ãtima, a velocidade de 50,5 cm s-1. O preparo da amostra foi realizado com a precipitaÃÃo das proteÃnas do plasma seguida de microextraÃÃo em fase sÃlida no modo headspace (MEFS-HS) do sobrenadante; para otimizaÃÃo da extraÃÃo foi realizado planejamento fatorial 22 com componente central, em 3 fibras com caracterÃsticas diferentes. A fibra Polidimetilsiloxano/Divinilbenzeno (PDMS/DVB) de 65Âm mostrou uma maior afinidade com os analitos, sendo determinada como condiÃÃes Ãtimas o tempo de 40 min. de extraÃÃo com NaCl 30 % p/v de forÃa iÃnica e 110 ÂC de temperatura; o pH 5,5, agitaÃÃo de 1000 rpm e vial de 40 mL foram mantidos constantes. Foi validado um mÃtodo para determinaÃÃo quantitativa apenas para o carbaril, sendo esse monitorado pelo sinal do 1-naftol. A % de 1-naftol produzido pela degradaÃÃo tÃrmica do carbaril, nas condiÃÃes de MEFS e no CG-EM, foram respectivamente de 8% determinado por RMN e 94 % determinado pelo sinal gerado no detector EM. A seletividade foi avaliada na matriz de plasma sanguÃneo para amostras normais, lipÃmica e hemolisada, sendo o mÃtodo bem seletivo. A faixa linear de trabalho foi de 12 a 180 Âg L-1; utilizando o mÃtodo de superposiÃÃo da matriz com a utilizaÃÃo do pirimicarbe como padrÃo substituto, a linearidade da curva de calibraÃÃo foi determinada pelo valor do coeficiente de correlaÃÃo (R = 0,999), sendo realizado um estudo mais aprofundado da linealidade. Os valores do limite de detecÃÃo e quantificaÃÃo foram de 3,0 e 12,0 Âg L-1, o que demonstra que pequenas concentraÃÃes podem ser analisadas pelo mÃtodo; a precisÃo e exatidÃo intra e inter corrida foram todos dentro do recomendado pela resoluÃÃo da AgÃncia Nacional de VigilÃncia SanitÃria Brasileira n 27/2012, menores que 15 % para concentraÃÃes mÃdias e altas e, menores que 20 % para baixas concentraÃÃes. Amostras de 10 trabalhadores da regiÃo foram analisadas, porÃm nÃo foi detectada presenÃa de carbaril e carbofurano no plasma desses indivÃduos. / The presence of pesticides is increasing concern in Brazil since 2007 to 2012, the volume of pesticides (considering only the active ingredient) applied to the crops grew 14 %. The uncontrolled use of these compounds has offered risks to workers and residents of the areas of agribusiness. A survey conducted by a group of Federal University of CearÃ, showed that in 23 samples of water from the irrigated perimeter region of low Jaguaribe, collected at different locations and analyzed by liquid chromatography, all showed the presence of some pesticides, highlighting the carbaryl and carbofuran as the most detected. One study found chromosomal abnormalities in bone marrow cells of individuals exposed to pesticides in the region, which reinforces the need to develop bioanalytical methods able to detect pesticides in biological samples, for which exposure can be monitored by competent authorities. Based on that a method was developed for analysis of carbaryl and carbofuran, using a gas chromatograph equipped with mass detector, it was monitored the analytical signal of pesticides and their respective products of thermal degradation, degradation that occurred gun chromatograph. A study to determine the appropriate line speed for the method was carried out with the construction of the Van Deemter diagram, being determined as great as the speed of 50.5 cm s-1. Sample preparation was carried out with the precipitation of the plasma proteins microextraction followed by solid phase in the headspace (HS-SPME) of the supernatant; to extract optimization was performed factorial design with central component 22 in three fibers having different characteristics. The Polydimethylsiloxane/Divinylbenzene fiber (PDMS/DVB) of 65 μm showed a higher affinity for analytes and determined as optimum conditions the time of 40 min. extraction with NaCl 30 % w/v of ionic strength and temperature of 110 ÂC; pH 5.5, stirring speed of 1000 rpm and 40 ml vial were kept constant. A method for quantitative determination has been validated only for carbaryl, making monitored by signal 1-naphthol. The % 1-naphthol produced by thermal degradation of carbaryl in the conditions of SPME and GC-MS were respectively determined by NMR 8 % and 94 % as determined by the generated signal detector. The selectivity was evaluated in blood plasma matrix for normal, hemolyzed, and lipemic samples, the highly selective method. The linear response range was 12-180 μg L-1; using the matrix method of superposition using the substitute pattern as pirimicarb, the linearity of calibration curve was determined by the value of the correlation coefficient (R = 0.999), being conducted further study of the linearity. The values of detection and limit of quantification were 3.0 and 12.0 μg L-1, demonstrating that small concentrations can be analyzed by the method; the precision and accuracy intra and inter race were all within the recommended resolution by the National Sanitary Surveillance Agency No. 27/2012, less than 15% for medium to high concentrations and lower than 20 % for low concentrations. Samples of 10 workers in the region were analyzed, but was not detected presence of carbaryl and carbofuran in plasma of these individuals.
14

Avaliação de custo e eficácia de métodos e critérios de teste baseado em Máquinas de Estados Finitos / Evaluate of cost and effectiveness of FSM based testing methods and criteria

Dusse, Flávio 16 December 2009 (has links)
MÉTODOS de geração de casos de teste visam a gerar um conjunto de casos de teste com uma boa relação custo/benefício. Critérios de cobertura de teste definem requisitos de teste, os quais um conjunto de teste adequado deve cobrir. Métodos e critérios visam a selecionar casos de teste baseados em especificações, que podem ser descritas por meio de modelos, tais como Máquinas de Estados Finitos (MEF). Existem diversos métodos de geração e critérios de cobertura, diferindo entre si em função das propriedades exigidas da MEF, do custo dos testes gerados e da eficácia na revelação de defeitos. Apesar de pesquisas intensas na definição desses métodos e critérios, são poucas as ferramentas de apoio disponíveis assim como são poucos os relatos de aplicação em termos de custo e eficácia para a definição de estratégias de teste efetivas. Dessa forma, é necessário obter dados reais das vantagens e desvantagens dos métodos e critérios para subsidiar a tomada de decisão no processo de desenvolvimento de software no que tange às atividades de teste e validação. Este trabalho apresenta resultados de experimentos para avaliar o custo e a eficácia de aplicação dos métodos e critérios mais relevantes para subsidiar a definição de estratégias de teste em diversos contextos, como por exemplo, no desenvolvimento de protocolos e de sistemas reativos. Utiliza-se um protótipo desenvolvido a partir de uma reengenharia da ferramenta Plavis/FSM para apoiar os experimentos / TEST case generation methods aim to generate a test suite that offers an acceptable trade-off between cost and avail. Test coverage criteria define testing requirements, which an adequate test suite must fulfill. Methods and criteria help to select test case from specifications, which can be describe as models, for example Finite State Machines (FSM). There are several generation methods and coverage criteria that differ depending on the required properties of the FSM, the cost of generated tests and the effectiveness in revealing faults. In spite of intense researches in the definition of those methods and criteria, there are few available tools to apply them as well as application reports about cost and effectiveness issues to define effective test strategies. Thus, it is necessary to obtain real data of the advantages and disadvantages of the methods and criteria to provide decision-making in the software development process as far in the validation and test activities. This work aimed to lead experiments to evaluate the cost and the effetiveness in applying the most relevant methods and criteria to subsidize test strategies definition in several contexts as the communication protocol development and the reactive systems development. A prototype was developed based on reengineering of the Plavis/FSM tool to support the experiments
15

Avaliação de custo e eficácia de métodos e critérios de teste baseado em Máquinas de Estados Finitos / Evaluate of cost and effectiveness of FSM based testing methods and criteria

Flávio Dusse 16 December 2009 (has links)
MÉTODOS de geração de casos de teste visam a gerar um conjunto de casos de teste com uma boa relação custo/benefício. Critérios de cobertura de teste definem requisitos de teste, os quais um conjunto de teste adequado deve cobrir. Métodos e critérios visam a selecionar casos de teste baseados em especificações, que podem ser descritas por meio de modelos, tais como Máquinas de Estados Finitos (MEF). Existem diversos métodos de geração e critérios de cobertura, diferindo entre si em função das propriedades exigidas da MEF, do custo dos testes gerados e da eficácia na revelação de defeitos. Apesar de pesquisas intensas na definição desses métodos e critérios, são poucas as ferramentas de apoio disponíveis assim como são poucos os relatos de aplicação em termos de custo e eficácia para a definição de estratégias de teste efetivas. Dessa forma, é necessário obter dados reais das vantagens e desvantagens dos métodos e critérios para subsidiar a tomada de decisão no processo de desenvolvimento de software no que tange às atividades de teste e validação. Este trabalho apresenta resultados de experimentos para avaliar o custo e a eficácia de aplicação dos métodos e critérios mais relevantes para subsidiar a definição de estratégias de teste em diversos contextos, como por exemplo, no desenvolvimento de protocolos e de sistemas reativos. Utiliza-se um protótipo desenvolvido a partir de uma reengenharia da ferramenta Plavis/FSM para apoiar os experimentos / TEST case generation methods aim to generate a test suite that offers an acceptable trade-off between cost and avail. Test coverage criteria define testing requirements, which an adequate test suite must fulfill. Methods and criteria help to select test case from specifications, which can be describe as models, for example Finite State Machines (FSM). There are several generation methods and coverage criteria that differ depending on the required properties of the FSM, the cost of generated tests and the effectiveness in revealing faults. In spite of intense researches in the definition of those methods and criteria, there are few available tools to apply them as well as application reports about cost and effectiveness issues to define effective test strategies. Thus, it is necessary to obtain real data of the advantages and disadvantages of the methods and criteria to provide decision-making in the software development process as far in the validation and test activities. This work aimed to lead experiments to evaluate the cost and the effetiveness in applying the most relevant methods and criteria to subsidize test strategies definition in several contexts as the communication protocol development and the reactive systems development. A prototype was developed based on reengineering of the Plavis/FSM tool to support the experiments

Page generated in 0.029 seconds