• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 975
  • 16
  • 16
  • 15
  • 15
  • 11
  • 9
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 994
  • 994
  • 577
  • 427
  • 417
  • 290
  • 177
  • 138
  • 122
  • 105
  • 99
  • 85
  • 71
  • 70
  • 65
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
481

Protocolo de tratamento de superficie de pino de fibra de quartzo com H2O2 / Surface treatment protocol of fiber-glass with peroxide hidrogeny

Menezes, Murilo de Sousa 04 June 2009 (has links)
Orientador: Luis Roberto Marcondes Martins / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T12:27:27Z (GMT). No. of bitstreams: 1 Menezes_MurilodeSousa_D.pdf: 3933379 bytes, checksum: 5a242574b594d3fc29d4767d06e9d5cb (MD5) Previous issue date: 2009 / Resumo: O objetivo deste estudo foi avaliar a resistência de união entre pinos de fibra de quartzo e resina de preenchimento, preliminarmente em função do uso do silano isoladamente e silano associado ao adesivo. Em seguida, em função do condicionamento de superfície do pino com peróxido de hidrogênio (H2O2), variando a concentração (24 e 50%) e o tempo de aplicação (1, 5 e 10 min). Propôs-se também, avaliar qualitativamente, por meio de Microscopia Eletrônica de Varredura (MEV), a morfologia de superfície dos pinos tratados com H2O2 em diferentes protocolos de aplicação, comparativamente ao pino sem nenhum tratamento de superfície. Para avaliar a resistência de união 80 pinos de fibra de quartzo (AESTHETI-PLUS, Bisco) foram divididos, aleatoriamente, em oito grupos (n=10): inicialmente, foram testados (G1) tratado apenas com silano e (G2) tratado com silano e adesivo, para definição do grupo controle. Os grupos experimentais (G3) tratado com H2O2 a 24% por 1 min; (G4), H2O2 a 24% por 5 min; (G5), H2O2 a 24% por 10 min; (G6), H2O2 a 50% por 1min; (G7), H2O2 a 50% por 5 min e (G8), H2O2 a 50% por 10 min. Em seguida, todos os grupos experimentais receberam aplicação de uma camada de silano (PORCELAIN PRIMER, Bisco) e outra de adesivo (ALL BOND 2, Bisco). Em seguida as restaurações em resina composta (CORE-FLO, Bisco) foram simuladas utilizando moldes de silicones. Após 24h de armazenagem em água a 37ºC, as amostras foram submetidas a cortes seriados, perpendiculares ao longo eixo do pino, obtendo amostras com dimensões de aproximadamente 1x1mm, com formato de palito e constituída por resina/pino/resina. As amostras foram submetidas ao ensaio mecânico de microtração à velocidade de 0,5 mm/min até o rompimento dos espécimes. Para análise em MEV, 14 pinos foram divididos em sete grupos (n=2): G1 (controle) sem tratamento nenhum; e os outros seis grupos receberam o mesmo tratamento de superfície com H2O2 correspondente as amostras do ensaio de microtração, entretanto, sem aplicação de silano e adesivo. Os dados de resistência de união apresentaram distribuição normal e homogênea e foram submetidos ao teste t-Student para comparar o grupo G1 ao G2. Os resultados mostraram que G2 apresentou valor de resistência de união significantemente superior ao G1, sendo então considerado como controle para posterior comparação aos grupos experimentais. Em seguida, para comparar entre si os grupos tratados com H2O2, foi aplicada análise de variância fatorial ANOVA (3x2). Foi também realizado Post Hoc Tests Dunnett, para comparação do grupo controle (G2) aos grupos experimentais (tratados com H2O2) em análise de fator único. Os resultados demonstraram que os grupos experimentais apresentaram valores de resistência de união semelhantes entre si e superiores ao controle (G2). As imagens de MEV demonstraram que o tratamento de superfície com H2O2 remove parcialmente a resina epóxica dos pinos expondo as fibras de quartzo. Conclui-se que o H2O2 altera a morfologia de superfície dos pinos de fibra de vidro e aumenta a resistência de união entre o pino e resina de preenchimento. / Abstract: Coupling of fiber posts to composites is hampered by absence of chemical union between epoxy-based resins. This study analyzed the effect of surface treatments of glass fiber posts on bond strength to resin cores. A total of 94 fiber posts (AESTHETI-PLUS, Bisco) were randomly divided into eight groups, according to the surface pre-treatments performed (n=10): (G1), silanization; (G2), silanization and adhesive. Six experimental groups: (G3) 24% hydrogen peroxide (H2O2) for 1 min; (G4), 24% H2O2 for 5 min; (G5), 24%H2O2 for 10 min; (G6), 50% H2O2 for 1min; (G7), 50% H2O2 for 5 min and (G8), 50% H2O2 for 10 min. This was followed by silanization (PORCELAIN PRIMER, Bisco) of the exposed quartz fiber to enhanced their chemical bonding to core composite and application of bonding agent (ALL BOND 2, Bisco). Two posts of each experimental group and two posts without the treatment were investigating the morphologic aspect surface post. The composite resin (CORE-FLO, Bisco) was used for the core build-up in ten remaining posts of each group. The samples were cut so as to obtain microtensile sticks that were loaded in tension at cross-heat speed of 0,5mm/min until failure. Data were statistically analyzed. SEM examination showed pretreatment with H2O2 modifying the fiber post surface. The post-core strengths achieved in G2 were significantly higher, that G1. The experimental groups G3, G4, G5, G6, G7 and G8 were similar and significantly higher, that G2. In conclusion the adhesive and silane enhanced the interfacial strength between them and core material. The hydrogen peroxide modified the surface morphology of fiber post and also significantly enhanced the interfacial strength between them and core material. / Doutorado / Dentística / Doutor em Clínica Odontológica
482

Efeito do condicionamento acido do esmalte na adptação marginal 'in vivo' de restaurações indiretas em resina composta cimentadas com material autoadesivo / The effect of enamel etching on the 'in vivo' marginal adaptation of indirect composite resin restorations luted with a self-adhesive material

Sartori, Cristiana Godoy, 1967- 13 August 2018 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T22:52:00Z (GMT). No. of bitstreams: 1 Sartori_CristianaGodoy_M.pdf: 5052776 bytes, checksum: d305b8dc296a1c6feb6d207ea417904d (MD5) Previous issue date: 2009 / Resumo: Estudos in vitro tem sugerido o condicionamento ácido do esmalte antes da cimentação de restaurações indiretas com o cimento autoadesivo RelyX Unicem. Entretanto, não existe comprovação científica de que este procedimento tenha alguma relevância clínica. O objetivo deste estudo in vivo, foi avaliar o efeito do condicionamento ácido do esmalte na qualidade marginal de restaurações indiretas, tipo inlay/onlay de resina composta, utilizando o cimento autoadesivo RelyX U100. Foram selecionados 42 dentes posteriores de 25 pacientes que apresentaram 1 ou 2 dentes com restaurações extensas insatisfatórias, necessitando substituição. Os dentes foram preparados para receberem restaurações indiretas do tipo inlay/onlay. Imediatamente após o preparo cavitário, os dentes foram moldados com silicone polimerizado por adição e protegidos com material temporário. As restaurações em resina composta foram confeccionadas sobre troqueis de gesso de acordo com a técnica por camadas. O tempo de fotoativação foi de 40s para opacidade dentina e 20s para as demais, utilizando um aparelho de luz emitida por diodo (LED). Uma semana depois, os pacientes retornaram para cimentação das restaurações indiretas. Os dentes foram isolados com lençol de borracha e as restaurações foram cimentadas aleatoriamente de acordo com um dos protocolos: Grupo condicionado - condicionamento ácido do esmalte + cimento autoadesivo; Grupo não condicionado - cimento autoadesivo. As restaurações foram mantidas sob pressão por 2 minutos, enquanto se procedia à remoção dos excessos de cimento, e em seguida foram fotoativadas por 60s em cada face. O acompanhamento clínico foi realizado 1 semana (início) e 12 meses após a cimentação, quando os dentes foram fotografados, moldados e avaliados conforme escores pré-estabelecidos (critério USPHS). Réplicas em resina epóxica foram examinadas em microscopia eletrônica de varredura (MEV) com aumentos de 18X a 200X. Os resultados foram calculados em porcentagem do comprimento total da margem visível para cada parâmetro. Não houve diferença estatística entre os grupos, com exceção da característica 'fratura marginal da restauração' na avaliação em MEV, para o grupo não condicionado. O tempo contribuiu significativamente para a degradação das margens sendo que a presença de underfilling de cimento foi a característica mais frequente. Concluiu-se que, o condicionamento ácido do esmalte, antes da utilização do cimento autoadesivo RelyX U100, não teve relevância clínica na qualidade marginal de restaurações indiretas de resina composta no período avaliado. E ainda, que a presença de pequenos defeitos marginais não interferiu na longevidade clínica das restaurações que alcançaram um mínimo 93,75% de critério Alpha aos 12 meses. / Abstract: In vitro studies have suggested enamel-etching before luting indirect restorations with the self-adhesive cement RelyX Unicem. However, there is no scientific proof that this procedure has any clinical relevance. The aim of this in vivo study was to evaluate the effect of enamel etching on the marginal quality of indirect composite resin restorations (inlay/onlay) using the self-adhesive cement RelyX U100. Forty-two posterior teeth were selected from 25 patients that presented one or two teeth with large restorations in need of replacement. The teeth were prepared for indirect restorations (inlay/onlay). Next, the teeth were molded with polyvinylsiloxane and protected with interim restorations. The composite resin restorations were built over plaster casts using the incremental technique. Using a LED device, increments were light-cured for 40s for dentin opacity shades and 20s for all other shades. After one week, patients returned so that indirect restorations could be cemented. Teeth were isolated with rubber dams and the restorations were luted according to one of the following protocols: Etched group - selective enamel-etching + self-adhesive cement; Non-etched group - selfadhesive cement alone. The restorations were kept under finger-pressure for 2 minutes while removing excess cement. Each face was then light-cured for 60s. Recalls occurred after 1 week (baseline) and 12 months when the teeth were photographed, molded and evaluated according to previously established scores (USPHS criteria). Epoxy resin replicas were examined by SEM at X18 to X200. The results were expressed as percentage of the total observable marginal length for each parameter. No statistical difference was found between groups with an exception for the 'restoration margin fracture' quality (MEV analysis) for the nonetched group. Time degraded somewhat the restorations margins with underfilling being the more frequent find. We concluded that enamel-etching had no clinical relevance on marginal quality for indirect composite resin restorations luted with RelyX U100 self-adhesive cement during 12 months. Moreover, the presence of small marginal defects did not interfere in the clinical longevity of the restorations that reached at least 93,75% of the Alpha criteria after 12 months. / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
483

Nanomanipulação e caracterização de nano-objetos individuais por experimentos in situ de microscopia eletrônica / Nanomanipulation and characterization of individual nano-objects for in situ experiments of electron microscopy

Nakabayashi, Denise Basso 23 March 2007 (has links)
Orientador: Daniel Mario Ugarte / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-08-08T03:21:06Z (GMT). No. of bitstreams: 1 Nakabayashi_DeniseBasso_D.pdf: 11254474 bytes, checksum: 322d16fa27f12c3eba14b8083c744b09 (MD5) Previous issue date: 2007 / Resumo: Há grandes expectativas de que, no futuro, componentes de alta tecnologia sejam baseados em novas e inesperadas propriedades físicas e químicas de objetos nanométricos. Muitas aplicações exigem que nano-objetos sejam posicionados precisamente em áreas bem definidas de um componente. Entretanto, os métodos estabelecidos de manipulação física usados na escala macroscópica não são aplicáveis na escala nanométrica. Muitas questões continuam em aberto e os avan»cos no estudo de nanossistemas são lentos. Muitos experimentos tem explorado a manipulação física usando microscopias de força atômica (AFM) e de tunelamento (STM), mas, nestes métodos, manipulação e observação não podem ser realizadas simultaneamente. Os microscópios eletrônicos de varredura (SEM) e de transmissão (TEM) são equipamentos essenciais no estudo de nano-objetos devido µa sua alta resolução e µa possibilidade de observar os movimentos realizados in situ em tempo real. Unindo esta técnica ao uso de nanomanipuladores, obtemos uma ferramenta poderosa para manipular e caracterizar nano-objetos. Existem diversos nanomanipuladores comerciais que operam em SEMs. Entretanto, o custo destes instrumentos é elevado, e os mesmos ficam restritos a grandes centros de pesquisa. Nesta tese, descrevemos o desenho, construção e aplicação de nanomanipuladores com uma ou duas pontas de prova, cujos sistemas são baseados em mecânica simples e materiais de baixo custo. Estes sistemas operam dentro de um SEM equipado com um canhão por emissão de campo (FEG-SEM, JSM-6330F, resolução nominal 1.5 nm a 25 kV). Os movimentos grosseiros são baseados em um sistema elásticos (um eixo de movimento) e em uma modificação inovadora deste sistema. Em tal modificação, dois sistemas elásticos são acoplados, o que gera movimentos em dois eixos. Quanto aos movimentos finos, um conjunto de elementos piezoelétricos é responsável pelo deslocamento preciso em três eixos independentes de cada ponta de prova. O porta-amostra possui um grande deslocamento (15 mm), o que nos permite trabalhar com várias amostras em um mesmo experimento. Os instrumentos desenvolvidos permitem uma grande variedade de experimentos de nanomanipulação e nanocaracterização, incluindo a medicão de correntes e a aplicação de voltagens. Os sistemas foram usados em diversos experimentos, tais como: a) fabricação de pontas de AFM de alta razão de aspecto baseadas em nanotubos de carbono multi-camadas; b) coletar, mover e posicionar nanofios semicondutores (100 - 300 nm de diâmetro, microns de comprimento) em contatos elétricos pré-definidos ou em áreas específicas de uma amostra; c) fabricação e caracterização elétrica de dispositivo eletrônico baseado em nanofios semi-condutores; d) caracterização das propriedades mecânicas de nano-objetos unidimensionais, como nanotubos de carbono e nanofios; etc. Finalmente, nossos resultados de manipulação demonstram que existem muitas oportunidades para a aplicação de manipulação física no método "bottom-up"em nanotecnologia / Abstract: It is expected that, in the future, high-technology devices should be based on new and unexpected physical and chemical properties of nanometric objects. Many applications require nano-objects to be selectively positioned at well-defined positions of a device. However, the well-established methods of physical manipulation used in the macroscopic scale are not applicable in nanoscale. Here, there are lots of open questions and the progress is still rather slow. Several experiments have exploited physical manipulation using atomic force microscopy (AFM) and scanning tunnelling microscopy (STM), but, in these techniques, manipulation and observation can not be performed simultaneously. The scanning (SEM) and transmission (TEM) electron microscopes are essential equipments for studying nano-objects due to their high resolution and to the possibility of observing performed movements in real time. Those techniques, together with the use of nanomanipulators, are powerful tools to manipulate and characterize nano-objects. There are several commercial nanomanipulators for SEMs. However, the price of these instruments is reasonably high, and they become restricted to a few research groups. In this work, we report the development and applications of home-made nanomanipulators (with one or two probe tips) whose systems are based on simple mechanics and on low-cost materials. They operate inside a FEG-SEM (JSM-6330F, 1.5 nm nominal resolution at 25 kV). The coarse movements rely on parallel guiding spring based mechanics (one axis of movement) and on two overlapped parallel guiding spring based mechanics (two axes of movement). The precise movements are due to an ensemble of piezoelectric elements that has three independent axes of movement for each probe tip. The sample support has a large range (15 mm) on one axis, which allows working with several samples during the same experiment. The instruments are suitable for a wide spectrum of nanomanipulation and nanocharacterization experiments, including measuring currents and applying voltages. The systems have been used for a variety of applications, such as: a) fabricating high aspect-ratio AFM tips based on multi-walled carbon nanotubes; b) collecting, moving, and positioning semiconductor nanowires (100 - 300 nm in diameter, microns in length) on predefined electrical contacts or special sample sites; c) fabrication and electrical characterization of an electronic device based on semiconductor nanowires; d) characterization of mechanical properties of one-dimensional nano-objects, as carbon nanotubes and nanowires; etc. Brie°y, our manipulation results demonstrate that there are plenty of opportunities for applications of physical manipulation in the bottom-up approach to nanotechnology / Doutorado / Física da Matéria Condensada / Doutor em Ciências
484

Estudo da conformabilidade plastica do aço microligado 27MnSiVS6 forjado por Ausforming / Study on the workability when ausforming the microalloyed steel 27MnSiVS6

Caminaga, Celio 23 July 2007 (has links)
Orientador: Sergio Tonini Button / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-08-09T12:42:48Z (GMT). No. of bitstreams: 1 Caminaga_Celio_D.pdf: 45945732 bytes, checksum: 36b9f4a15a23ccd9e0ad12b26cfe5931 (MD5) Previous issue date: 2007 / Resumo: A exigência por parte das montadoras por produtos com maior qualidade, a preços mais baixos e com diminuição do prazo de entrega, faz com que as indústrias de autopeças concentrem esforços na busca de processos e materiais alternativos. Os processos de forjamento a quente aliados aos aços microligados, que também são conhecidos como aços de alta resistência e baixa liga (ARBL), tem uma extensa aplicação em componentes automotivos. A proposta deste trabalho é estudar o comportamento microestrutural e mecânico (resistência e tenacidade) do aço microligado 27MnSiVS6, quando empregado no processo ausforming, a fim de analisar-se o desempenho do processo e a qualidade dos produtos, comparando-o com os processos de forjamento a quente e a morno. Os produtos forjados proveniente do processo de ausforming que foram submetidos aos ensaios de tração unidirecional, dureza, fadiga em flexão rotativa e tenacidade a fratura apresentaram as melhores propriedades mecânicas. A microscopia óptica e microscopia eletrônica (varredura e transmissão) que foram utilizadas para caracterização microestrutural dos produtos forjados demonstraram o refino dos grãos ferríticos, a presença de inclusões não metálicas (MnS) e a contribuição dos mecanismos de endurecimento ao limite de escoamento. Os testes estatísticos aplicados aos resultados permitiram concluir, que os produtos obtidos pelo processo de forjamento ausforming apresentam a melhor combinação de resistência mecânica e qualidade superficial dos produtos forjados, sem aumentar a carga de forjamento / Abstract: The demand of the automotive industry for parts with high overall quality, low costs and reduced time to market, forced the suppliers to search alternative materials and manufacturing processes. Hot forgings with microalloyed steels, also known as HSLA (High Strength Low Alloy), represent an extensive application in automotive parts. The main objective of this work is to study the workability of a microalloyed steel deformed by ausforming and compare the products microstructures and forming loads to those obtained by hot and warm forging. Results from preliminary upsetting tests confirmed the viability of this study. Finally forgings tests were held to define the forming load and to analyze products microstructures for these three processes. Forgings were analyzed by tensile tests, fatigue under cyclic flexion tests, and fracture toughness tests. Optical and electronic microscopy (SEM and TEM) applied to evaluate the forgings microstructure showed the ferritic grain refinement, the presence of non-metallic inclusions (MnS) and confirmed the contribution of hardening mechanisms to increase the yield strength of forging products. The statistical analysis of the experimental results showed that ausforming is a suitable process to substitute hot and warm forging since ausforming presented lower loads when compared to warm forging, and ausformed forgings presented the best combination of mechanical strength and surface quality, without a significant increase of the forging loads / Doutorado / Materiais e Processos de Fabricação / Doutor em Engenharia Mecânica
485

Estudo de microdureza e profundidade de lesões de cárie artificiais produzidas por diferentes métodos / Evaluation of dentin caries like-lesions produced by different models

Pacheco, Larissa Ferreira, 1983- 15 August 2018 (has links)
Orientador: Regina Maria Puppin-Rontani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T22:54:34Z (GMT). No. of bitstreams: 1 Pacheco_LarissaFerreira_M.pdf: 2738346 bytes, checksum: a45f65b512f358ab0bd0c6efb39313e0 (MD5) Previous issue date: 2010 / Resumo: A utilização de materiais restauradores unidos ao substrato dentinário tem sido um desafio que vem sendo superado nos últimos anos. Pesquisas têm conseguido aperfeiçoar a união dos materiais ao substrato dentinário, porém, a maioria dos estudos utiliza dentina hígida, uma vez que a utilização da dentina após remoção de cárie, isto é o substrato dentinário afetado pela cárie torna as pesquisas de difícil execução. Dentre os principais motivos destaca-se a difícil seleção de lesões similares, sendo, portanto um desafio para os pesquisadores pela variabilidade encontrada nos resultados não se alcançando a devida evidência científica para a aplicação das técnicas de união. A fim de aprimorar os estudos sobre este tipo de substrato, o objetivo deste estudo foi avaliar diferentes modelos de produção de cárie: modelo biológico e modelo in situ, comparando-os quanto a microdureza e profundidade de cárie à lesão de dentes extraídos com cárie. Foram utilizados 15 terceiros molares, compreendendo 5 dentes extraídos com cárie (cárie oclusal de profundidade média - C, grupo controle), 10 dentes eram hígidos, dos quais 5 foram utilizados para o modelo de produção de cárie in situ (IS) e 5 para o modelo biológico (MB). De todos os dentes foram obtidos blocos de dentina de 4x4x2 mm. Os blocos de dentina hígida foram analisados quanto à microdureza de superfície (SMH) e depois submetidos ao processo de cárie artificial. Após o desafio cariogênico, os blocos dos 3 grupos (C, IS, e MB) foram seccionados longitudinalmente ao centro obtendo-se dois hemi-blocos um dos quais foi submetido à análise da microdureza longitudinal (CSMH), e o outro à análise em Microscopia Eletrônica de Varredura (MEV). A microdureza longitudinal foi medida em 4 colunas com 8 pontos diferentes (com distância de 20µm entre as cinco indentações iniciais e 100µm entre as três finais), obtendo-se uma média de medidas por bloco. Os hemi-blocos restantes foram submetidos à análise em MEV para verificação da profundidade da lesão (X25 e X200), que foi medida na região mais profunda de cada uma delas. Os dados obtidos na análise da microdureza de superfície e longitudinal da lesão foram submetidos ao teste t, ANOVA e teste de Tukey, respectivamente (p<0,05). E os dados obtidos na análise de profundidade da lesão pelo MEV foram submetidos a ANOVA e teste de Tukey (p<0,05). Os resultados da microdureza de superfície após a produção de cárie mostrou que houve diferença significante entre os modelos de produção de cárie biológico e in situ, sendo que o modelo biológico não diferiu da lesão de cárie natural. Na microdureza longitudinal o modelo in situ apresentou nenhuma diferença estatística da cárie natural, mas o menor valor de CSMH foi observado na cárie produzida pelo modelo biológico. Na análise do MEV a lesão de cárie em dentina produzida pelo modelo biológico e a dentina cariada naturalmente tiveram profundidades similares, e o modelo in situ apresentou a menor profundidade de lesão de cárie. Baseado nos resultados obtidos neste estudo, foi concluido que os dois métodos de produção de cárie mostraram características similares ao da lesão de cárie natural em dentina nos diferentes testes realizados: microdureza de superfície e longitudinal, e Microscopia Eletrônica de Varredura. / Abstract: The use of restorative materials attached to the dentin substrate has been a challenge that has been overcome in the last years. Research has been able to improve the bonding between the materials and dentin substrate, however, the most studies use sound dentin, since the use of dentin after caries remove, such as dentin substrate affected make research difficult to perform. Among the main reasons stand the difficult selection of similar lesions, and, therefore a challenge to the researchers for the variability found in the results not reaching the proper scientific evidence for the application of bonding techniques. In order to improve the researches about this specific substrate, the aim of this study was to evaluate different models to produce caries, using the biological model, and the in situ model, comparing them about the cross-sectional microhardness and caries depth with the natural carious lesion, thus, extract teeth with caries dentin. Were used 15 third molars, including 5 teeth with natural caries (occlusal caries with average depth- CN), 10 teeth were sound, which 5 were used for the in situ production model of caries (IS) and 5 for the biological model (MB). Of all the teeth were obtained dentin samples with 4x4x2mm. Sound dentin samples were submitted to surface microhardness analysis and after to artificial caries process. After the cariogenic challenge, samples of the three groups (CN, IS, e MB) were cross sectioned to the center obtaining two sections which one was submitted cross-sectional microhardness analysis (CSMH) and the other to Scanning Electron Microscopy (SEM). Samples were analyzed as cross-section hardness in 4 columns with 8 different points (with a distance of 20µm between the first five indentations and 100µm between the last three) obtaining average measures for sample. The rest of sections were submitted to analysis by SEM to check the depth of the lesion, which was measured in the deepest region of each one. The data obtained by microhardness analysis and the depth lesion by SEM were submitted to ANOVA 2 criteria and t test, and ANOVA and Tukey test, respectively (p<0,05). Results of surface microhardness after to artificial caries process showed significantly difference between biological model and in situ model, and the biological model had no difference to natural caries. In the cross-sectional microhardness in situ model present no statistically difference from natural caries, but the lowest CSMH was observed for biological model of caries producing. SEM analysis, the artificial carious dentin lesions produced by biological model and natural carious dentin had similar depth, and the in situ model had the lowest depth of carious lesion. Based on the obtained results of this study it was concluded that both methods showed similar characteristics to natural caries dentin but concerning different tests: surface and cross-sectional microhardness, and scanning electron microscopy. / Mestrado / Odontopediatria / Mestre em Odontologia
486

Análise morfológica da superfície dentinária hígida e afetada por cárie e da camada híbrida após aplicação de emulsão à base de óleo de copaíba (Copaifera multijuga Hayne)

Moura, Luanny Gomes, 92-3345-1345 07 March 2016 (has links)
Submitted by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-07-18T14:35:48Z No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Reprodução Não Autorizada.pdf: 47716 bytes, checksum: 0353d988c60b584cfc9978721c498a11 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-07-18T14:36:03Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Reprodução Não Autorizada.pdf: 47716 bytes, checksum: 0353d988c60b584cfc9978721c498a11 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2017-07-18T14:36:19Z (GMT) No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Reprodução Não Autorizada.pdf: 47716 bytes, checksum: 0353d988c60b584cfc9978721c498a11 (MD5) / Made available in DSpace on 2017-07-18T14:36:19Z (GMT). No. of bitstreams: 2 license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Reprodução Não Autorizada.pdf: 47716 bytes, checksum: 0353d988c60b584cfc9978721c498a11 (MD5) Previous issue date: 2016-03-07 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / The copaiba oleoresin, extracted from Copaifera multijuga Hayne is used popularly for various purposes. Because of biological properties, a copaiba oil emulsion was formulated to be used before applying the adhesive in order to improve the quality of dentin bonding. The aim of this study was to evaluate the morphological characteristics of the dentin surface and the hybrid layer formed with etch-and-rinse and self-etching adhesive systems in sound and caries-affected dentin after using copaiba oil emulsion. 96 third molars from Biobank of the School of Dentistry, University Federal of Amazonas, were used. Half of the teeth underwent artificial induction of dental caries and the other half was formed by sound teeth. All teeth had their roots removed; yielding dentine disks were divided into groups according to test substances (2% chlorhexidine, copaiba oil emulsion, calcium hydroxide solution and distilled water), the dentin (sound or caries-affected) and the adhesive system (Adper Single Bond 2® or Clearfil SE Bond®). The dentin surface and the hybrid layer of the obtained specimens were analyzed by SEM according to the experimental groups. The treatment of dentin surface with copaiba oil emulsion showed no physical barrier to the adhesive penetration. The dentin surface treated with 2% chlorhexidine showed phosphate salts in two types of dentin. The treatment of the dentin surface with calcium hydroxide solution resulted in the deposition of mineral precipitate obstructing the lumen of the tubules in sound dentin. The calcium hydroxide solution applied on the conditioned sound dentin was different from the other substances (p<0.05). In smeared surface, distilled water in sound dentin showed a significant difference from all experimental groups (p <0.05). There was no statistical difference between the hybrid layer formed with the Adper Single Bond 2® adhesive in sound and caries-affected dentin treated with the test substances. The hybrid layer with Clearfil SE Bond® in caries-affected dentin treated with copaiba oil emulsion showed no statistical difference in relation to the tested substances, shown statistical difference only with calcium hydroxide solution in caries-affected dentin (p <0.05). In sound dentin, there was no statistical difference in the hybrid layer with Clearfil SE Bond® irrespective of the tested substances. The application of copaiba oil emulsion showed no morphological change in sound and caries-affected dentin, regardless of phosphoric acid etching; and presented a uniform hybrid layer, regular and large monomer infiltration in sound and caries-affected dentin, regardless of the adhesive system. / O óleo-resina de copaíba, extraído da Copaifera multijuga Hayne é usado, popularmente, com diversas finalidades. Diante das suas propriedades biológicas, foi criada uma emulsão à base de óleo de copaíba para ser usada antes da aplicação do adesivo com a finalidade de melhorar a qualidade da adesão dentinária. O objetivo do estudo foi avaliar as características morfológicas da superfície dentinária e da camada híbrida formada com os sistemas adesivos convencional e autocondicionante nas dentinas hígida e afetada por cárie após o uso da emulsão à base de óleo de copaíba. Foram utilizados 96 terceiros molares humanos hígidos do Biobanco da Faculdade de Odontologia da Universidade Federal do Amazonas (FAO – UFAM). Metade dos dentes sofreu indução artificial de cárie e a outra metade foi formada pelos dentes hígidos. Todos os dentes tiveram suas raízes removidas, obtendo-se discos de dentina que foram divididos em grupos de acordo com as substâncias testes (clorexidina a 2%, emulsão à base de óleo de copaíba, solução de hidróxido de cálcio e água destilada), o substrato dentinário (hígido ou cariado) e o sistema adesivo (Adper Single Bond 2® ou Clearfil SE Bond®). A superfície dentinária e a camada híbrida dos espécimes obtidos foram analisadas em MEV, de acordo com os grupos experimentais. O tratamento da superfície dentinária com emulsão à base de óleo de copaíba não apresentou nenhuma barreira física aparente à penetração do adesivo. A superfície dentinária tratada com clorexidina a 2% apresentou sais de fosfato nos dois tipos de dentina. O tratamento da superfície com solução de hidróxido de cálcio resultou na deposição de precipitado mineral, obstruindo a luz dos túbulos dentinários em dentina hígida. A solução de hidróxido de cálcio aplicada sobre a dentina hígida condicionada foi diferente das demais substâncias (p<0,05). Na superfície não condicionada, a água destilada em dentina hígida apresentou diferença significativa em relação a todos os grupos experimentais (p< 0.05). Não houve diferença estatística entre as camadas híbridas formadas com o adesivo Adper Single Bond 2® nas dentinas hígidas e afetadas por cárie tratadas com as substâncias testes. A camada híbrida com Clearfil SE Bond® na dentina afetada por cárie tratada com emulsão à base do óleo de copaíba não apresentou diferença estatística em relação às substâncias testes, apresentando diferença somente em relação à solução de hidróxido de cálcio na dentina afetada (p<0,05). Na dentina hígida, não houve diferença estatística na camada híbrida com Clearfil SE Bond®, independente das substâncias testadas. A aplicação da emulsão à base de óleo de copaíba não apresentou nenhuma alteração morfológica nas superfícies dentinárias hígida e afetada por cárie, independente do condicionamento com ácido fosfórico; e apresentou uma camada híbrida uniforme, regular e com grande infiltração monomérica nas dentinas hígida e afetada por cárie, independente do adesivo utilizado.
487

A influência do aquecimento na estrutura semicristalina da Polianilina Sal de Esmeraldina (PANI-ES)

Oliveira, Lilian Rodrigues 19 October 2015 (has links)
Submitted by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-04-19T15:14:04Z No. of bitstreams: 1 Dissertação - Lilian Rodrigues.pdf: 4077944 bytes, checksum: 1080d415cdaa70f7cb353c9e979ded24 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-04-19T15:14:41Z (GMT) No. of bitstreams: 1 Dissertação - Lilian Rodrigues.pdf: 4077944 bytes, checksum: 1080d415cdaa70f7cb353c9e979ded24 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2016-04-19T15:14:58Z (GMT) No. of bitstreams: 1 Dissertação - Lilian Rodrigues.pdf: 4077944 bytes, checksum: 1080d415cdaa70f7cb353c9e979ded24 (MD5) / Made available in DSpace on 2016-04-19T15:14:58Z (GMT). No. of bitstreams: 1 Dissertação - Lilian Rodrigues.pdf: 4077944 bytes, checksum: 1080d415cdaa70f7cb353c9e979ded24 (MD5) Previous issue date: 2015-10-19 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Polyaniline (PANI) is an Intrinsically Conducting Polymer (ICP) which is very studied in several areas due to their technological applications. The purpose of this study is to investigate the changes occurring in the structure, morphology and electrical conductivity of Polyaniline Esmeraldine Salt form (PANI-ES) when it is subjected to heat treatment at temperatures of 50, 100, 200 and 300 °C for 1h at each temperature. PANI-ES was chemically synthesized with ammonium persulfate and HCl 1M, and the samples were characterized using XRD, SAXS, FTIR and SEM techniques. By XRD a loss of crystallinity was observed after heating treatment. XRD data were also used to perform the Le Bail method in order to obtain microstructural information through FullProf program and to estimate the percentage of crystallinity using the Peak Fitting Module program. Through Le Bail method the values of average and anisotropic crystallite sizes were acquired: for PANI-ES it was found the value of 36 Å and for the heat treated samples, TT (50) TT (100), TT (200) and TT (300), these values were gradually narrowed until it reaches 16 Å at 300 °C. The percentage of crystallinity obtained for the PANI-ES and heat-treated samples ranged from 51 to 19%. Through the SAXS technique it were obtained the values of the radius of gyration (Rg), and the maximum particle size (Dmáx) from the pair distribution function p(r). The SAXS data were also used for structural reconstruction of the model for particle size, showing that the increasing of temperatures caused a significant loss of globular particle shape and their maximum particle size (Dmáx) and radius of gyration (Rg) were decreased after the heat treatment. FTIR analyzes showed a crosslinking reaction when PANI-ES was subjected to 200 °C, with no gain of crystallinity. SEM technique allowed different morphologies visualization: PANI-ES showed a nanofiber morphology formed by interconnected nanospheres, while samples heat treated lost this initial morphology having much smaller and less defined nanofibers, reflecting the loss of electrical conductivity and crystallinity. The electrical conductivity measurements have been decreasing because of the heat treatment: PANI-ES showed electrical conductivity of 0.3 x 10-4 S/cm and, after the heat treatment, the electric conductivity reached 4 x 10-6 S/cm, representing a decrease of 86%. Thus, this research allowed the structural and morphological characterization of PANI-ES, investigating the changes in its structure after heat treatment, and found that the decrease in the percentage of crystallinity influences in their electrical conductivity values. It is hoped that these results will contribute to a better understanding of the structural, morphological and electrical properties of polymeric materials / A polianilina (PANI) é um polímero intrinsecamente condutor (PIC) que é muito estudado em diversas pesquisas devido as suas aplicações tecnológicas. O intuito desta pesquisa é investigar as modificações ocorridas na estrutura, morfologia e condutividade elétrica da Polianilina Sal de Esmeraldina (PANI-ES), quando a mesma é submetida a tratamento térmico nas temperaturas de 50, 100, 200 e 300°C, com duração de 1h para cada temperatura. A PANI-ES foi sintetizada quimicamente com Persulfato de Amônio e HCl 1M e as amostras foram caracterizadas utilizando-se as técnicas de DRX, SAXS, FTIR e MEV. Através dos dados obtidos por DRX, verificou-se a perda de cristalinidade das amostras tratadas termicamente através da modificação dos perfis dos difratogramas. Os dados de DRX também foram utilizados para realização do ajuste Le Bail visando à obtenção de informações microestruturais através do programa FULLPROF e para a estimativa do percentual de cristalinidade utilizando o programa Peak Fitting Module. No ajuste Le Bail foram adquiridos os valores dos tamanhos médios e anisotrópicos dos cristalitos: para a PANI-ES foi encontrado o valor de 36 Å e para as amostras tratadas termicamente, TT (50), TT (100), TT (200) e TT (300), este valor foi gradativamente diminuindo até chegar a 16 Å em 300 °C. Os percentuais de cristalinidade obtidos para PANI-ES e as amostras tratadas termicamente variaram de 51 para 19%. Através do SAXS foram obtidos os valores dos raios de giro (𝑅𝑔) e a dimensão máxima das partículas (𝐷𝑚á𝑥 ) a partir da função de distribuição de pares p(r). Os dados de SAXS também foram utilizados para reconstrução estrutural do modelo do formato das partículas, mostrando que a temperatura ocasionou a perda do formato globular das partículas, bem como suas dimensões máximas e raios de giro foram diminuídos com o tratamento térmico. As análises de FTIR revelam que, quando a PANI-ES é submetida a 200°C ocorre uma mudança estrutural na cadeia polimérica através da reação de crosslinking, porém, sem ganho de cristalinidade. As imagens de MEV permitiram a visualização das distintas morfologias das amostras: a PANI-ES apresentou uma morfologia de nanofibras formadas por nanoesferas interconectadas, enquanto que as amostras tratadas termicamente perderam essa morfologia inicial, apresentando nanofibras muito menores e menos definidas, refletindo na perda de cristalinidade e condutividade elétrica das amostras. As medidas de condutividade elétrica foram diminuindo em virtude do tratamento térmico: a PANI-ES apresentou condutividade elétrica da ordem de 0,3 x 10-4 S/cm e, após o tratamento térmico, a condutividade elétrica chegou a 4 x 10-6 S/cm, representando uma diminuição de 86%. Assim, esta pesquisa permitiu, através da caracterização estrutural e morfológica da PANI-ES, investigar as alterações ocorridas em sua estrutura após o tratamento térmico, e constatar que a diminuição do percentual de cristalinidade influencia nos valores de condutividade elétrica. Espera-se que estes resultados possam contribuir para um maior conhecimento das propriedades estruturais, morfológicas e elétricas dos materiais poliméricos
488

Avaliação da ultraestrutura e ação de desinfetantes em Trypanosoma vivax (Ziemann, 1905) / Ultrastructure and disinfectant action evaluation in Trypanosoma vivax (Ziemann, 1905)

Madrid, Darling Mélany de Carvalho 31 July 2017 (has links)
Submitted by JÚLIO HEBER SILVA (julioheber@yahoo.com.br) on 2017-08-22T17:14:03Z No. of bitstreams: 2 Dissertação - Darling Mélany de Carvalho Madrid - 2017.pdf: 9281142 bytes, checksum: 7c28bb567493636c0dd23e77fa2de0ff (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-09-15T12:12:53Z (GMT) No. of bitstreams: 2 Dissertação - Darling Mélany de Carvalho Madrid - 2017.pdf: 9281142 bytes, checksum: 7c28bb567493636c0dd23e77fa2de0ff (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-09-15T12:12:53Z (GMT). No. of bitstreams: 2 Dissertação - Darling Mélany de Carvalho Madrid - 2017.pdf: 9281142 bytes, checksum: 7c28bb567493636c0dd23e77fa2de0ff (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2017-07-31 / Trypanosoma vivax (Ziemann, 1905) is a protozoon responsible for causing trypanosomiasis in bovines, a disease currently increasing in Brazil and, in the state of Goiás, it was first identified in 2015. As it causes abortion, lethality and greatly diminishes milk production, trypanosomiasis may cause significant losses to farmers, especially those working with milk production. However, there is not much information about this protozoon in Brazil. As it is necessary to gather more knowledge about isolates in the country to evaluate the disease real prevalence, impact in economy and, more importantly, develop control programs, this work proposed evaluate the morphometry of this parasite in scanning electron microscopy and the efficacy of different disinfectants in its elimination. Scanning electron microscopy is a highresolution technique used to analyze the external structures of the parasite, which shows morphometric differences between Latin America and Brazilian isolates. In this work, it was shown that there is no size difference among isolates found in Brazil and Goiás. The results of disinfectants efficacy evaluation to eliminate this agent have shown that many disinfectants commonly found in the market may be used. This information may be applied directly in farms to help control infection focus and contribute in reducing the disease impact in Brazilian milk production. / Trypanosoma vivax (Ziemann, 1905) é o protozoário responsável por causar a tripanossomíase em bovinos, doença que atualmente expressa caráter epidêmico no Brasil e, no estado de Goiás, foi identificada pela primeira vez em 2015. Por ocasionar aborto, letalidade e grande queda de produção de leite, a tripanossomíase pode gerar grandes prejuízos ao produtor, principalmente os que trabalham com bovinocultura de leite. Apesar disto, ainda não há muitas informações disponíveis sobre este protozoário no Brasil. Considerando a necessidade de conhecer mais as características dos isolados presentes no país a fim de avaliar sua prevalência real, impacto na economia e, principalmente, desenvolvimento de programas de controle, este trabalho se propôs avaliar a morfometria do parasito em microscopia eletrônica de varredura e a eficácia de diferentes desinfetantes na sua eliminação. A microscopia eletrônica de varredura é uma técnica de alta resolução empregada para analisar a estrutura externa do parasito, que apresenta diferenças morfométricas entre os isolados na América Latina e no Brasil. Neste trabalho, ficou evidenciado que não há diferença de tamanho entre os isolados encontrados no Brasil e em Goiás. Os resultados da avaliação da eficácia dos desinfetantes em eliminar o agente demonstram que diversos desinfetantes comumente encontrados no mercado podem ser empregados. Estas informações podem ser aplicadas diretamente em propriedades para auxiliar no controle de surtos e contribuir na redução dos impactos causados nos rebanhos bovinos de leite brasileiros.
489

Efeito da espessura da camada de cimento na integridade e resistência adesiva de pinos de resina reforçados por fibra de vidro / Effect of the thickness of the resin cement on the bond integrity and strength of glass fiber fiber-reinforced composite post

Katia Rodrigues Reis 05 June 2009 (has links)
A perda de adesao e uma falha comum reportada para os pinos reforçados por fibra e usualmente ocorre ao longo da interface adesiva entre a dentina radicular e o cimento resinoso. A espessura de cimento resinoso ideal para preservar a continuidade da interface adesiva cimento-dentina e aumentar a retencao do pino e desconhecida. O objetivo deste estudo foi avaliar a influencia da espessura do cimento na integridade e na resistencia adesiva de dois cimentos resinosos empregados para a cimentacao de pinos reforcados por fibra. Trinta incisivos laterais superiores humanos com comprimentos radiculares semelhantes foram selecionados, secionados na juncao cimento-esmalte e tratados endodonticamente. As raizes foram aleatoriamente divididas em seis grupos (n=5), e os condutos radiculares foram preparados a uma profundidade de 8 mm usando uma das três brocas com diametro diferente: Broca Largo n 3 para o grupo controle (L3 1 mm); Broca Largo n&#8501; 4 (L4 - 1,25 mm) e Broca Largo n&#8501; 5 (L5 1,5 mm) para os grupos experimentais. Pinos de resina reforcados por fibra de vidro (Fibrekor post, Jeneric Pentron), 1 mm de diametro, foram cimentados aos condutos radiculares utilizando o cimento resinoso dual (Duolink, Bisco) ou o cimento resinoso autopolimerizavel (C&B Cement, Bisco). A porcao de cada especime contendo os pinos reforcados por fibra foi secionada transversalmente em tres secoes (cervical, media e apical) de 2 mm de espessura utilizando um disco diamantado em maquina de corte seriado sob refrigeracao com agua. As secoes foram polidas, limpas ultrassonicamente e duplicadas com polivinil siloxano. Replicas em resina epoxica das secoes foram obtidas para a mensuracao da espessura do cimento e da integridade adesiva na interface cimento-dentina por meio de MEV. As secoes foram armazenadas em solucao fisiologica a 37o C por uma semana e, entao, submetidas ao teste push-out em uma maquina de ensaio universal a velocidade de 0,5 mm/min-1, e a forca maxima requerida para deslocar cada pino foi registrada (N). Os dados foram analisados usando ANOVA a um criterio, teste de Tukey e teste t de Student (&#945;=0,05). A correlacao entre a integridade adesiva, a resistencia adesiva e a espessura do cimento tambem foi determinada pelo coeficiente de Pearson (&#945;=0,05). A comparacao multipla entre as condicoes experimentais para cada cimento revelou que os valores medios de integridade adesiva (%) e de resistencia adesiva (MPa) dos pinos reforcados por fibra cimentados com o cimento resinoso Duolink foram significantemente maiores no grupo controle (L3: 61,79 ± 18,06 e 11,32 ± 4,66) do que no grupo experimental com camada de cimento muito espessa (L5: 38,91 ± 5,75 e 4,68 ± 2,16) (p=0,018 e p=0,035), respectivamente. Embora nao tenha sido observada diferenca significante na integridade adesiva entre as diferentes espessuras de cimento avaliadas para o cimento resinoso C&B Cement (p>0,05), o grupo com camada de cimento muito espessa (L5: 10,67 ± 4,59) foi significantemente mais retentivo do que o grupo controle (L3: 4,01 ± 0,76) (p=0,014). A comparacao entre cimentos para cada condicao experimental mostrou que o cimento resinoso Duolink foi mais retentivo do que o cimento resinoso C&B Cement no grupo controle (11,32 ± 4,66 e 4,01 ± 0,76, p=0,008), ao passo que o cimento resinoso C&B Cement foi mais retentivo do que o cimento resinoso Duolink em L5 (4,68 ± 2,19 e 10,67 ± 4,59, p=0,030), respectivamente. Somente a comparação entre o grupo experimental L4 e os outros grupos nao foi significante para ambos os cimentos resinosos e testes realizados. O aumento da espessura do cimento diminuiu significantemente a integridade adesiva (r=-0,5901; p=0,021) e a resistência adesiva (r=-0,5387; p=0,038) para o cimento resinoso Duolink. A integridade adesiva correlacionou-se positivamente com a resistencia adesiva para esse tipo de cimento resinoso (r=0,6855; p=0,005). Diferentemente, nao foi encontrada correlação significante entre a espessura do cimento e a integridade adesiva (r=0,153; p=0,586) e nem entre a integridade adesiva e a resistencia adesiva (r=0,2969; p=0,283) registradas para C&B Cement. Contudo, o aumento da espessura deste tipo de cimento resinoso aumentou significantemente a retencao do pino (r=0,6576; p=0,008). Os dados sugeriram que a espessura da camada dos cimentos resinosos influenciou a integridade adesiva e a resistencia adesiva dos pinos de resina reforcados por fibra. Para o cimento resinoso Duolink selecionado, os maiores valores de integridade adesiva e de resistencia adesiva foram obtidos quando a camada mais fina de cimento foi testada (L3). Contudo, o cimento resinoso C&B Cement apresentou maior retencao quando a espessura da camada de cimento aumentou muito (L5), embora a espessura do cimento nao tenha desempenhado um papel importante na integridade adesiva da interface cimento-dentina para esse cimento resinoso. / Debonding is the most common cause of failure reported for glass fiberreinforced composite posts and occurs frequently along the adhesive interface between the resin cement and the root dentin. The ideal thickness of the resin cement to preserve the continuity along the cement-dentin interface and to increase the retention of the post is unknown. The purpose of this study was to evaluate the influence of the thickness of the resin cement on the bond integrity and strength of two resin cements used for glass fiber-reinforced composite posts cementation. 30 human maxillary incisors with similar root dimensions were selected, sectioned at the amelocemental junction and endodontically treated. The roots were randomly divided into six groups (n=5), and the post spaces were prepared 8 mm deep using one of the three burs with different diameters: Largo bur n&#8501; 3 for the control group (L3 1- mm); Largo bur n&#8501; 4 (L4 1,25-mm) e Largo bur n&#8501; 5 (L5 1,5-mm) for the experimental groups. Fiber-reinforced composite posts (Fibrekor post, Jeneric Pentron), 1-mm diameter, were cemented to post spaces by using the dual-cure (Duolink, Bisco) or self-cure system (C&B Cement, Bisco). The portion of each specimen that contained the bonded fiber post was sectioned into three 2-mm thick serial slices (cervical, middle, apical) with the Isomet saw under water cooling. The slices were polished and ultrasonicated in deionized water. Polyvinyl siloxane impressions of the observable surfaces were taken and the surfaces replicated with epoxy resin for measuring of the thickness of the resin cement and the bond integrity by using MEV. The slices were stored in physiologic solution at 37o C for one week, and then submitted to the push-out test at a crosshead speed of 0.5 mm/min-1. The maximum force required to dislocate each post was registered (N). Data were analyzed by one-way ANOVA, Tukey test and t test (&#945;=0,05). The correlation between bond integrity, bond strength and thickness of the resin cement was also determined by correlation test (&#945;=0,05). The multiple comparison test between the experimental conditions for each resin cement showed that the mean values of bond integrity (%) and strength (MPa) of the fiber posts cemented with Duolink were significantly higher at the control group (L3: 61.79 ± 18.06 and 11.32 ± 4.66) than those obtained for the experimental groups with the thicker layer cement (L5: 38.91 ± 5.75 and 4.68 ± 2.16) (p=0.018 and p=0.035), respectively. Although there was no significant difference on the bond integrity between the different thicknesses evaluated for C&B Cement (p>0.05), the group with thicker layer (L5: 10.67 ± 4.59) was significantly more retentive than the control group (L3: 4.01 ± 0.76) (p=0.014). The comparison between cements for each experimental condition has showed that Duolink was more retentive than C&B Cement at the control group (11.32 ± 4,66 and 4.01 ± 0,76, p=0.008), whereas C&B Cement was more retentive than Duolink at L5 group (4.68 ± 2.19 and 10.67 ± 4.59, p=0.030), respectively. Only the comparison between the L4 experimental group and the others groups was not significant for both resin cements and tests conducted. The increase of the thickness of the cement significantly reduced the bond integrity (r=-0.5901; p=0.021) and strength (r=-0,5387; p=0.038) for Duolink. Bond integrity positively correlated with bond strength for this type of resin cement (r=0.6855; p=0.005). On the other hand, there was no significant correlation between the thickness of the cement and the bond integrity (r=0.153; p=0.586) and neither between the bond integrity and strength (r=0.2969; p=0.283) registered for C&B Cement. However, the increase of the thickness of this type of resin cement has significantly increased the retention of the post (r=0.6576; p=0.008). Data suggested that the thickness of resin cements affected both the bond integrity and strength of fiber posts. For the Duolink resin cement selected, the higher values of bond integrity and strength were obtained when the thinner layer was tested (L3). However, C&B Cement has showed higher retention when the thickness of the cement increased excessively (L5), though the thickness of the cement has not played a role on the bond integrity of the cement-dentin interface for this resin cement.
490

Análise comparativa dos aspectos da ultraestrutura do espermatozoide de Mico-Leão-de-Cara-Dourada (Leontopithecus chrysomelas) e Bugio (Alouatta caraya e Alouatta guariba clamitans) / Ultrastructure characteristics comparative analysis of spermatozoa from Golden-headed Lion Tamarin (Leontopithecus chrysomelas) and Howler Monkey (Alouatta caraya and Alouatta guariba clamitans)

Ana Paula Grabner 13 June 2016 (has links)
Os primatas neotropicais, ou primatas do novo mundo, são pertencentes a um grupo diverso e variado de animais, com características anatômicas, comportamentais e taxonômicas próprias, que os diferem dos primatas do velho mundo. Estima-se que representem 31% dos primatas não-humanos do planeta. Têm sofrido com as altas taxas de crescimento populacional e perturbação antrópica resultante do desflorestamento, agricultura e criação de gado. Com o intuito de reverter esta situação e maximizar o potencial reprodutivo das espécies, o desenvolvimento de biotecnologias associadas à reprodução tem sido amplamente justificado nos dias de hoje, por representarem importantes ferramentas reprodutivas, contribuindo para a preservação da biodiversidade e manutenção da diversidade genética. Assim, o objetivo do presente estudo foi padronizar a colheita de sêmen de Alouatta guariba clamitans por eletroejaculação por via retal com posterior análise do sêmen fresco, procedimentos nunca descritos para a espécie, e adaptar o método de preparo de sêmen de Leontopithecus chrysomelas, Alouatta caraya e Alouatta guariba clamitans para microscopia eletrônica de transmissão, permitindo a comparação da ultraestrutura dos espermatozoides das três espécies e apresentando resultados também inéditos na literatura científica. Para este estudo, foram utilizados quatro exemplares de L. chrysomelas, dois exemplares de A. caraya e dois exemplares de A.g. clamitans, machos adultos mantidos em cativeiro. L. chrysomelas tiveram o sêmen colhido por vibroestimulação peniana, e A. caraya e A.g. clamitans foram submetidos à eletroejaculação por via retal. Após a obtenção dos ejaculados, o sêmen foi avaliado quanto ao volume, pH, concentração, motilidade, integridade de membrana plasmática, integridade de membrana acrossomal e morfologia, e posteriormente preparado para microscopia eletrônica de transmissão. A análise dos 12 espermatozoides das três espécies estudadas revelou que todos apresentam os componentes básicos descritos para o espermatozoide humano cabeça, colo e cauda, formada pelas peças intermediária, principal e terminal com variações na forma e tamanho de cada componente. As diferenças mais significativas encontradas entre os espermatozoides comparados foram extensão de acrossomo, comprimento, largura e organização de peça intermediária. O presente estudo atingiu os objetivos propostos, apresentando resultados inéditos na literatura científica / The neotropical primates, also known as primates of the new world, are a diverse and varied group of animals, with unique anatomical and taxonomic characteristics, as well a unique behaviour, that distinguish those from the old world primates. It is estimated that these present 31% of the non-human primate population of the planet. High taxes of populational growth and anthropological disturbance have been undergoing due to deforestation, agriculture and cattle farms. In order to revert this situation and maximize the reproductive potential of the species, the development of biotechnologies associated to the reproduction are widely justified nowadays, for representing important reproductive tools, contributing to the preservation of the biodiversity and maintenance of genetic diversity. Hence, the purpose of this study was to collect Alouatta guariba clamitans semen by rectal electroejaculation then analyze the fresh semen, procedures never before described for the species, and adapt the preparation method of Leontopithecus chrysomelas, Alouatta caraya and Alouatta guariba clamitans semen for electron transmission microscope, allowing the comparison of the spermatozoa ultrastructure from the three species and also presenting new results to the scientific literature. For this study, it was used four specimens of L. chrysomelas, two specimens of A. caraya and two specimens of A.g. clamitans, adult males kept in captivity. L. chrysomelas had the semen taken by penine vibratory stimulation, and A. caraya and A.g. clamitans were submitted to rectal electroejaculation. After the semen was obtained, it was evaluated regarding the volume, pH, concentration, motility, sperm membrane integrity, acrosome integrity and morphology, and then prepared for electron transmission microscopy. The analysis of the spermatozoa of the three studied species revealed that all present the basic components described for the human spermatozoa - head, neck region and tail, formed by middle, principal and terminal pieces - with variations in 14 shape and size of each component. The most significant differences found between the compared spermatozoa were the acrosome extension and middle piece length, thickness and organization. The present study attained the proposed goals, presenting unprecedented results for the scientific literature

Page generated in 0.505 seconds