• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 38
  • 5
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 48
  • 23
  • 9
  • 8
  • 8
  • 8
  • 8
  • 8
  • 8
  • 6
  • 6
  • 6
  • 6
  • 6
  • 5
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Estudo dos mecanismos de fadiga e análise de desempenho em mola para válvula automotiva em regime de alto e ultra-alto ciclo. / Study on the fatigue mechanisms and performance analysis in automotive valve spring under high-and-ultra-high-cycle regime.

Serbino, Edison Marcelo 05 March 2012 (has links)
Este trabalho apresenta um estudo dos mecanismos de fadiga em mola para válvula automotiva, realizado através da análise do comportamento mecânico correlacionado ao aspecto microestrutural. As amostras foram fabricadas em aço de alta resistência Si-Cr, submetidas a tratamentos térmicos convencionais (têmpera e revenimento) e não convencionais (austêmpera), obtendo um mesmo nível de dureza (aproximadamente 610 HV). Os corpos de prova foram submetidos a ensaios de bancada com diversos níveis de carregamentos, controlados através de variação da amplitude de tensão cisalhante. Esta variação promoveu diferentes regimes de fadiga, conhecidos como alto e ultra-alto ciclo, para maiores e menores níveis de amplitudes de tensões, respectivamente. O desempenho foi medido através do cálculo da vida total em fadiga, probabilidade de sobrevivência, além da verificação do relaxamento da força elástica e da tensão residual. As amostras foram caracterizadas através de métodos metalográficos, determinação da composição química, ensaios de dureza e resistência à tração, além de técnicas difratométricas de raios-X. As superfícies de fratura foram investigadas utilizando técnicas de microscopia eletrônica de varredura Os mecanismos de início e propagação das trincas, de ambas as amostras, foram semelhantes, apesar do tratamento térmico proposto de austêmpera produzir uma microestrutura mista, com predominância de bainita inferior, contendo regiões esparsas de austenita retida. A microestrutura bainítica, resultante da austêmpera, quando comparada com as amostras martensíticas, geradas pela têmpera e revenimento, propiciou um aumento da vida total em fadiga nos maiores níveis de amplitudes das tensões, tendendo à equalização com a diminuição desta amplitude, além de apresentarem um maior relaxamento elástico, gerando uma discreta diminuição de magnitude da tensão média. Por outro lado, não houve relaxamento das tensões residuais, em ambas as amostras, após uma quantidade significativa de ciclos, portanto este fenômeno não influenciou em sua vida total. / This paper presents a study on the valve spring fatigue mechanisms, carried out through analysis of mechanical behavior correlated to microstructural aspect. The samples were made of high strength steel Si-Cr, obtained by conventional (quenching and tempering) and unconventional (austempering) heat treatments, generating a single level of hardness (approximately 610 HV). The samples were subjected to bench test with various loading levels, controlled through shear stress amplitude fluctuation. This variation has promoted distinct fatigue regimes known as high and ultra-high cycle, for greater and smaller levels of stress amplitudes, respectively. The performance was measured by calculating the fatigue total life, survival probability, verification of the elastic force and residual stress relaxation. The samples were characterized by means of metallographic methods, chemical composition analysis, hardness/tensile strength testing and X-ray diffractometry techniques. The fracture surfaces were investigated using scanning electron microscopy techniques. The cracks initiation and propagation mechanisms were similar in both samples; despite the proposed austempering heat treatment produced a mixed microstructure with predominance of lower bainite, containing sparse regions of retained austenite. The bainitic microstructure, resulting of austempering, when compared with martensitic samples, generated by quenching and tempering, led to an increase in fatigue total life under higher levels of stress amplitudes, but tending to be the same as the stress amplitude deacresases and the number of cycles increases. On the other hand, there was no residual stresses relaxation in both samples, after a significant amount of cycles, so this phenomenon did not influence the total life.
12

Medidas das constantes de mola, de amortecimento e da temperatura para átomos aprisionados e para uma de suas variantes espaciais / Measurements of spring constants of force and damping and temperature of trapped atoms and in one of its spatial variants

Araujo, Maria Tereza de 17 February 1995 (has links)
Devido à necessidade de caracterizar as armadilhas magneto-ópticas (AMO), as quais fornecem amostras densas de átomos frios, e de extrema importância o conhecimento dos valores das constantes mecânicas k e &#946 inerentes ao movimento harmônico super amortecido dos átomos nestas armadilhas. Neste trabalho, obtivemos estas constantes usando a técnica que aplica uma oscilação forçada aos átomos aprisionados através de um pequeno campo magnético oscilante adicional de forma a não perturbar o aprisionamento. Fizemos um estudo destas constantes como função de alguns parâmetros inerentes ao aprisionamento, como por exemplo: intensidade dos feixes laser, gradiente de campo magnético e dessintonia. A manipulação de átomos aprisionados, obtida através da observação de diversas estruturas espaciais dos mesmos, mostra um certo controle sobre estes átomos e a obtenção de valores para a temperatura dos átomos nestas estruturas, permite uma maior compreensão do mecanismo de aprisionamento. Nos detivemos então, na medida da temperatura dos átomos aprisionados em estrutura espacial do tipo anel além de propor um modelo teórico simples capaz de justificar os resultados obtidos. / In order to have precise characterization of magneto-optical traps (MOT), which are used to obtain a dense sample of cold atoms, it is important to measure the mechanical constants k and &#946 of the over-damped harmonic motion that rule the motion of the atoms inside the MOT. In this work, we obtain these constants by applying a small additional a.c. magnetic field that does not perturb the trap d.c. field but forces the trapped atoms to oscillate. We studied the variation of the constants by changing laser intensities, trapping field gradient and detuning. The manipulation of trapped atoms and the observation of several kinds of spatial structures allow one to have a better comprehension of the trapping mechanism. We measured the temperature of the atoms in the ring type structure and a simple theoretical model that explains the results is proposed.
13

Análise comparativa de métodos de cálculo para fundações de máquinas

Milet, Rebecca Rolim January 2006 (has links)
Made available in DSpace on 2014-06-12T17:40:15Z (GMT). No. of bitstreams: 2 arquivo6175_1.pdf: 2149513 bytes, checksum: ab08c15764ba1f2e807eff02c748c551 (MD5) license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) Previous issue date: 2006 / Os avanços tecnológicos industriais, nas últimas décadas, geraram o desenvolvimento de máquinas de alta performance e precisão que, por sua vez, têm demandado projetos otimizados de suas fundações. Cada vez mais, diversas tentativas têm que ser consideradas para se obter projetos de fundações que conciliem a máxima eficiência com custos aceitáveis. A modelagem via método dos elementos finitos se constitui uma poderosa ferramenta que pode ser utilizada para prever, de maneira mais precisa, o comportamento desses elementos estruturais quando comparada com os métodos analíticos simplificados, disponíveis na literatura, que levam em conta, na sua formulação, várias hipóteses a fim de que possam ser utilizados. A presente pesquisa aborda os conceitos básicos da análise dinâmica de fundações de máquinas, discute sobre alguns métodos analíticos e numéricos disponíveis de projeto e apresenta algumas recomendações de projeto e prescrições normativas. Blocos de fundações de concreto armado para máquinas alternativas e de impacto, bem como fundações aporticadas de concreto armado para turbomáquinas foram analisadas. As freqüências naturais e amplitudes da análise de elementos finitos foram comparadas com os resultados decorrentes da utilização dos métodos analíticos. Além disso, foram considerados os esforços seccionais e as tensões necessárias para o detalhamento das armações. Os resultados das análises de elementos finitos mostraram boa concordância com aqueles obtidos com a utilização dos métodos analíticos
14

A contracepção hormonal durante o acompanhamento da gravidez molar influência o risco e a agressividade clínica da neoplasia trofoblástica gestacional controlando os fatores de risco?

Dantas, Patrícia Rangel Sobral. January 2017 (has links)
Orientador: Izildinha Maestá / Resumo: Objetivo. Avaliar a influência da contracepção hormonal (HC) no desenvolvimento da agressividade clínica da neoplasia trofoblástica gestacional (NTG) e no tempo para normalização da gonadotrofina coriônica humana (hCG). Desenho do estudo. Coorte retrospectiva. Local do estudo. Centro de Doença Trofoblástica Gestacional do Rio de Janeiro. Pacientes. Pacientes diagnosticadas com gravidez molar. Intervenção. Comparação entre mulheres usuárias de HC ou métodos de barreira (BM) durante todo o acompanhamento da GTD. Desfecho primário. Ocorrência de GTN pós-molar e intervalo para a normalização dos níveis de hCG. Resultados. O uso de HC não influenciou a ocorrência de GTN pós-molar (Odds ratio ajustada - ORa: 0.66, 95% CI: 0.24-1,12, p=0.060), a despeito do tipo de HC utilizada: progesterona isolada (ORa: 0,54, 95% CI: 0.29-1,01, p=0.060) ou contracepção hormonal oral combinada (COC) (ORa: 0.50, 95% CI: 0.27-1.01, p=0.060) ou com diferentes dosagens etinilestradiol, 15mcg (ORa: 1,33, 95% CI: 0.79-2,24, p=0.288), 20mcg (ORa: 1.02, 95% CI: 0.64-1.65, p=0.901), 30mcg (ORa: 1.17, 95%CI: 0.78-1,75, p=0.437) ou 35mcg (ORa: 0.77, 95%CI: 0.42-1,39, p=0.386).O tempo para normalização de hCG ≥ 10 semanas (ORa: 0.58, 95% CI: 0.43-1.08, p=0.071) ou tempo de remissão após quimioterapia ≥ 14 semanas (ORa: 0.60, 95% CI: 0.43-1.09, p=0.067) não diferiram significativamente entre os usuários de HC quando comparadas aos pacientes que utilizam BM, ao controlar outros fatores de risco usando regressão ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Objective. To evaluate the influence of hormonal contraception (HC) on the development and clinical aggressiveness of gestational trophoblastic neoplasia (GTN) and the time for normalization of human chorionic gonadotrophin (hCG) levels. Study design. Retrospective cohort. Setting. Rio de Janeiro Trophoblastic Disease Center. Patient(s). Women diagnosed with molar pregnancy. Intervention(s). Comparison between users of HC or barrier methods (BM) during the postmolar follow-up or postmolar GTN treatment. Main Outcome Measure(s). Occurrence of post-molar GTN and the time for hCG levels normalization. Result(s). The use of HC did not significantly influence the occurrence of postmolar GTN (ORa: 0.66, 95% CI: 0.24-1.12, p=0.060), despite different formulations: progesteroneonly (ORa: 0.54, 95% CI: 0.29-1.01, p=0.060) or combined oral contraception (COC) (ORa: 0.50, 95% CI: 0.27-1.01, p=0.60) or with different dosages of ethinyl estradiol: 15 mcg (ORa, 1.33, 95% CI 0.79-2.24, p=0.288), 20 mcg (ORa: 1.02, 95% CI: 0.64-1.65, p=0.901), 30 mcg (ORa: 1.17, 95% CI: 0.78-1.75, p=0.437) or 35 mcg (ORa: 0.77, 95% CI: 0.42-1.39, p=0.386). The time to hCG normalization ≥ 10 weeks (ORa: 0.58, 95% CI: 0.43-1.08, p=0.071) or the time to remission after chemotherapy ≥ 14 weeks (ORa: 0.60, 95% CI: 0.43-1.09, p=0.067) did not significantly differ among HC users when compared to patients using BM, when controlling for other risk factors using multivariate logistic regression. Conclusion(s). The use... (Complete abstract click electronic access below) / Doutor
15

Influência do local de seguimento da mola hidatiforme no prognóstico e tratamento da neoplasia trofoblástica gestacional pós-molar /

Dantas, Patrícia Rangel Sobral. January 2012 (has links)
Orientador: Izildinha Maestá / Coorientador: Marilza Vieira Cunha Rudge / Coorientador: Rafael Cortés-Charry / Banca: Antônio Rodrigues Braga Neto / Banca: Jurandyr Moreira de Andrade / Resumo: Avaliar o prognóstico da mola hidatiforme (MH) e tratamento da neoplasia trofoblástica gestacional (NTG) pós-molar acompanhadas no Centro de Referência para Doenças Trofoblásticas (CDT) versus outras instituições (OI). Estudo de coorte que incluiu 270 pacientes com MH (204 pacientes acompanhas do CDT-Botucatu, onde essa investigação está sendo realizada, e 66 pacientes inicialmente acompanhadas em OI). Todas as pacientes foram registradas no banco de dados do CDT-Botucatu (Universidade Estadual Paulista, Brasil) entre janeiro de 1990 e dezembro de 2009. O prognóstico da MH, bem como as características da NTG e seu desfecho foram analisados e comparados de acordo com o local de seguimento pós-molar. As seguintes variáveis de confundimento foram incluídas: idade (anos), número de gestação, paridade, número de abortamentos, e o tipo de MH (Completa/Parcial). O desfecho da NTG pós-molar consoante o local de seguimento pós-molar foi comparado utilizando-se o teste de Mann-Whitney, teste do Qui-Quadrado ou teste Exato de Fisher. NTG pós-molar ocorreu em 34 (34/204=16,7%) das pacientes que foram acompanhadas no CDT, e em 27 (27/66=40,9%) daquelas que realizaram o seguimento em OI. Pacientes que foram seguidas no CDT cursaram com características de NTG com melhor prognóstico, tais como: menor índice de metástases (5,8% versus 48%,p=0,003), menor mediana do escore FIGO 2000 [2,00 (1,00; 3,00) versus 4,00 (2,00; 7,00), p=0,003] e início mais precoce da quimioterapia em semanas [7,0 (6,0; 10,0) versus 10,0 (7,0; 16,0), p=0,04]. NTG de alto-risco não foi observada em nenhuma paciente submetida ao EUCDT, ocorrendo em 29% daquelas que foram acompanhadas em OI (p<0,001). Quimioterapia com múltiplos agentes para o tratamento da NTG pós-molar foi necessária em dois casos... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: To review treatment results of gestational trophoblastic neoplasia (GTN) after hydatidiform mole (HM) evacuation at a referral center (ERC) versus HM evacuation at other institutions (EOI). This cohort study included 270 patients undergoing HM evacuation (204 at the study referral center and 66 at other institutions). All patients were registered in the database of Botucatu Trophoblastic Diseases Center (São Paulo State University, Brazil) between January 1990 and December 2009. GTN characteristics and outcomes were analyzed and compared according to HM evacuation setting. The confounding variables assessed included age (years), number of gestations, parity, number of abortions, and HM type (Complete/Partial). Post-molar GTN outcomes according to HM evacuation setting were compared using Mann-Whitney's test, Chi-square test, or Fisher's exact test. Post-molar GTN occurred in 34 (34/204=16.7%) patients undergoing HM evacuation at the referral center, and in 27 (27/66=40.9%) of those undergoing HM evacuation in other institutions. Patients undergoing HM ERC showed GTN characteristics indicative of better prognosis such as: lower metastasis rate (5.8% versus 48%, p=0.003), lower median FIGO 2000 score [2.00 (1.00; 3.00) versus 4.00 (2.00; 7.00), p=0.003], and earlier chemotherapy onset in weeks [7.0 (6.0; 10.0) versus 10.0 (7.0; 16.0), p=0.04]. High-risk post-molar GTN was observed in no patient undergoing HM ERC, and in 29% of those undergoing HM EOI (p<0.001). Multi-agent chemotherapy for the treatment of post-molar GTN was required in two cases of HM evacuation at the referral center (5.9%) and in eight cases of HM EOI (29.6%) (p=0.017). Median time interval between chemotherapy onset and hCG. normalization in weeks was shorter among patients undergoing HM ERC [9.00 (6.25; 12.0) versus... (Complete abstract click electronic access below) / Mestre
16

A Data-Driven Approach for Mass-Spring Model Parametrization Based on Continuous Models

Silva, Josildo Pereira da 30 November 2015 (has links)
Submitted by Kleber Silva (kleberbs@ufba.br) on 2017-06-01T20:42:22Z No. of bitstreams: 1 Tese de Josildo.pdf: 4648596 bytes, checksum: 3ed7ce11dd70e411aa2271e15aeca67c (MD5) / Approved for entry into archive by Vanessa Reis (vanessa.jamile@ufba.br) on 2017-06-07T11:45:27Z (GMT) No. of bitstreams: 1 Tese de Josildo.pdf: 4648596 bytes, checksum: 3ed7ce11dd70e411aa2271e15aeca67c (MD5) / Made available in DSpace on 2017-06-07T11:45:27Z (GMT). No. of bitstreams: 1 Tese de Josildo.pdf: 4648596 bytes, checksum: 3ed7ce11dd70e411aa2271e15aeca67c (MD5) / Nowadays, the behavior simulation of deformable objects plays important roles in several fields such as computer graphics, computer aided design, computer aided surgery And robotics. The two main categories of deformable models are: based on continuum mechanics, like Finite Element Model (FEM) or Isogeometric Analysis (IGA); and using discrete representations, as a Mass - Spring Model (MSM). FEM methods are known for their high computational cost and precision, while MSM methods, although simple and affordable for real-time applications, are di cult to parameterize. There is no general physically based or systematic method in the literature to determine the mesh topology or MSM parameters from a known material. Therefore, in this thesis, we proposea methodology to parametrize the MSM based on continuous models with focus on the simulation of deformable objects in real-time for application in virtual environments. We developed two data-driven approaches to the parametrization of the MSM by using FEM and IGA models as reference of derivation with higher order elements. Based on experimental results, the precision achieved by these new methodologies is higher than other approaches in literature. In particular, our proposal achieves excellent results in the parametrization of the MSM with higher order elements which does not occur with other methodologies / Atualmente, a simula¸c˜ao de objetos deform´aveis desempenha papel importante em v´arios campos ligados `a Ciˆencia da Computa¸c˜ao, como a computa¸c˜ao gr´afica, projeto assistido por computador, cirurgias assistidas por computador e rob´otica. Nesse contexto, a simula¸c˜ao de objetos deform´aveis com acur´acia e em tempo-real ´e uma tarefa extremamente dificil para as aplica¸c˜oes que requerem simula¸c˜oes mecˆanicas interativas como s˜ao os casos dos ambientes virtuais, simuladores cir´urgicos e jogos. Podemos dividir as abordagens que d˜ao suporte ao tratamento de modelos deform´aveis em dois grandes grupos: baseados em mecˆanica do cont´ınuo, como M´etodo de Elementos Finitos (FEM - Finite Element Method) ou An´alise Isogeom´etrica (IGA - Isogeometric Analysis); e usando representa¸c˜oes discretas, como modelo massa-mola (MSM - Mass Spring Model). M´etodos baseados na abordagem cont´ınua s˜ao conhecidos por seu alto custo computacional e acur´acia, enquanto que os m´etodos discretos, embora simples e adequados para simula¸c˜oes mecˆanicas interativas, s˜ao dif´ıceis de parametrizar. A falta de um m´etodo geral baseado em f´ısica ou sistem´atico para determinar a topologia de malha ou os parˆametros do MSM a partir de um material conhecido foi a principal motiva¸c˜ao desse trabalho, no sentido de gerar um modelo de baixo custo computacional, como o MSM, a partir de um modelo de alta precis˜ao como o FEM. Portanto, partindo da premissa de simplicidade e adequa¸c˜ao do MSM para simula¸c˜oes mecˆanicas interativas, nesta tese propomos uma metodologia para parametrizar o MSM baseada em modelos cont´ınuos. Desenvolvemos duas abordagens orientadas `a dados (data-driven) para a parametriza¸c˜ao do MSM usando modelos FEM e IGA, este ´ultimo como referˆencia de deriva¸c˜ao com elementos de ordem superior. Com base nos resultados experimentais, a precis˜ao alcan¸cada por estas novas metodologias ´e mais elevada do que a de outros trabalhos similiares na literatura. Em particular, a nossa proposta alcan¸ca excelentes resultados na parametriza¸c˜ao do MSM com elementos de ordem superior
17

Comparação dos resultados da gravidez molar entre adolescentes da América do Norte e da América do Sul

Soares, Renan Rocha. January 2016 (has links)
Orientador: Izildinha Maestá / Resumo: Apesar de 10 a 34% das pacientes com gravidez molar serem adolescentes,a influencia da idade precoce na apresentação clínica e no risco de desenvolvimento deneoplasia trofoblástica gestacional pós-molar (GTN) ainda é incerto. Objetivos.Comparar a apresentação clínica da mola hidatiforme completa (MHC) e os fatores derisco associados com o desenvolvimento de NTG entre adolescentes da América doNorte e América do Sul. Métodos. Estudo de coorte não concorrente incluindoadolescentes (< 20 anos) com MHC tratadas em centro da América do Norte (NewEngland Trophoblastic Disease Center, Universidade de Harvard, Estados Unidos) entre1973-2009, e centros da América do Sul (Centro de Doença Trofoblástica de Botucatu –Universidade Estadual Paulista, Unesp, Brazil; Unidade Trofoblástica da UniversidadeCentral da Venezuela e Maternidad Concepción Palácios de Caracas, Venezuela), entre1990-2009. Dados clínicos das pacientes coletados foram idade, idade gestacional aodiagnóstico, tamanho do útero, hCG pré-esvaziamento, presença de cistostecaluteínicos, anemia, sangramento vaginal, pré-eclampsia e hiperemese. Asparticipantes do estudo foram alocadas em dois grupos de adolescentes: América doNorte (AN, n = 195) e América do Sul (AS, n = 231). Resultados. Na apresentação,anemia (AS = 48% vs AN = 15%; p <0,001), hiperemese (AS = 14% vs AN = 6%; p =0,003), e hCG sérico elevado (AS = 229591 mUI / mL vs AN = 14000 mUI / mL; p<0,001) foram mais frequentes na AS que... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Although 10-34% of patients with molar pregnancy are adolescent, theinfluence of young age on the clinical presentation and risk of developing post-molargestational trophoblastic neoplasia (GTN) is still unclear. Objectives. To comparecomplete hydatidiform mole (CHM) clinical presentation and risk factors associatedwith developing GTN between North American adolescents and South Americancounterparts. Methods. Non-concurrent cohort study including adolescents ( 20 years)with CHM referred to centers in North America (New England Trophoblastic DiseaseCenter, Harvard University,USA) between 1973-2009, and South America (BotucatuTrophoblastic Disease Center-São Paulo State University-Unesp, Brazil; TrophoblasticUnit of Central University of Venezuela and Maternidad Concepcion Palacios ofCaracas, Venezuela) between 1990-2009. Patient clinical data collected included age,gestational age at diagnosis, uterine size, pre-evacuation hCG, presence of theca luteincysts, anemia, vaginal bleeding, preeclampsia, and hyperemesis. Study participants wereallocated into two groups of adolescents: North American (NA,n=195) and SouthAmerican (SA,n=231). Results. At presentation, anemia (SA=48% vsNA=15%;p<0.001), hyperemesis (SA=14% vs NA=6%;p=0.003), and elevated serumhCG (SA=229591 mUI/mL vs NA=14000 mUI/mL ; p<0.001) were more frequent inSA than in NA. In SA, preeclampsia (SA:OR=4.33(1.37-13.65) vs NA:OR=0.34(0.04-2.86), uterine size>gestational age (SA:OR= 2... (Complete abstract click electronic access below) / Doutor
18

Influência do local de seguimento da mola hidatiforme no prognóstico e tratamento da neoplasia trofoblástica gestacional pós-molar

Dantas, Patrícia Rangel Sobral [UNESP] 27 February 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:29:51Z (GMT). No. of bitstreams: 0 Previous issue date: 2012-02-27Bitstream added on 2014-06-13T21:00:19Z : No. of bitstreams: 1 dantas_prs_me_botfm.pdf: 755908 bytes, checksum: 13b557cdff3e77e3ac4dd782fe68a76e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Avaliar o prognóstico da mola hidatiforme (MH) e tratamento da neoplasia trofoblástica gestacional (NTG) pós-molar acompanhadas no Centro de Referência para Doenças Trofoblásticas (CDT) versus outras instituições (OI). Estudo de coorte que incluiu 270 pacientes com MH (204 pacientes acompanhas do CDT-Botucatu, onde essa investigação está sendo realizada, e 66 pacientes inicialmente acompanhadas em OI). Todas as pacientes foram registradas no banco de dados do CDT-Botucatu (Universidade Estadual Paulista, Brasil) entre janeiro de 1990 e dezembro de 2009. O prognóstico da MH, bem como as características da NTG e seu desfecho foram analisados e comparados de acordo com o local de seguimento pós-molar. As seguintes variáveis de confundimento foram incluídas: idade (anos), número de gestação, paridade, número de abortamentos, e o tipo de MH (Completa/Parcial). O desfecho da NTG pós-molar consoante o local de seguimento pós-molar foi comparado utilizando-se o teste de Mann-Whitney, teste do Qui-Quadrado ou teste Exato de Fisher. NTG pós-molar ocorreu em 34 (34/204=16,7%) das pacientes que foram acompanhadas no CDT, e em 27 (27/66=40,9%) daquelas que realizaram o seguimento em OI. Pacientes que foram seguidas no CDT cursaram com características de NTG com melhor prognóstico, tais como: menor índice de metástases (5,8% versus 48%,p=0,003), menor mediana do escore FIGO 2000 [2,00 (1,00; 3,00) versus 4,00 (2,00; 7,00), p=0,003] e início mais precoce da quimioterapia em semanas [7,0 (6,0; 10,0) versus 10,0 (7,0; 16,0), p=0,04]. NTG de alto-risco não foi observada em nenhuma paciente submetida ao EUCDT, ocorrendo em 29% daquelas que foram acompanhadas em OI (p<0,001). Quimioterapia com múltiplos agentes para o tratamento da NTG pós-molar foi necessária em dois casos... / To review treatment results of gestational trophoblastic neoplasia (GTN) after hydatidiform mole (HM) evacuation at a referral center (ERC) versus HM evacuation at other institutions (EOI). This cohort study included 270 patients undergoing HM evacuation (204 at the study referral center and 66 at other institutions). All patients were registered in the database of Botucatu Trophoblastic Diseases Center (São Paulo State University, Brazil) between January 1990 and December 2009. GTN characteristics and outcomes were analyzed and compared according to HM evacuation setting. The confounding variables assessed included age (years), number of gestations, parity, number of abortions, and HM type (Complete/Partial). Post-molar GTN outcomes according to HM evacuation setting were compared using Mann-Whitney’s test, Chi-square test, or Fisher’s exact test. Post-molar GTN occurred in 34 (34/204=16.7%) patients undergoing HM evacuation at the referral center, and in 27 (27/66=40.9%) of those undergoing HM evacuation in other institutions. Patients undergoing HM ERC showed GTN characteristics indicative of better prognosis such as: lower metastasis rate (5.8% versus 48%, p=0.003), lower median FIGO 2000 score [2.00 (1.00; 3.00) versus 4.00 (2.00; 7.00), p=0.003], and earlier chemotherapy onset in weeks [7.0 (6.0; 10.0) versus 10.0 (7.0; 16.0), p=0.04]. High-risk post-molar GTN was observed in no patient undergoing HM ERC, and in 29% of those undergoing HM EOI (p<0.001). Multi-agent chemotherapy for the treatment of post-molar GTN was required in two cases of HM evacuation at the referral center (5.9%) and in eight cases of HM EOI (29.6%) (p=0.017). Median time interval between chemotherapy onset and hCG. normalization in weeks was shorter among patients undergoing HM ERC [9.00 (6.25; 12.0) versus... (Complete abstract click electronic access below)
19

Medidas das constantes de mola, de amortecimento e da temperatura para átomos aprisionados e para uma de suas variantes espaciais / Measurements of spring constants of force and damping and temperature of trapped atoms and in one of its spatial variants

Maria Tereza de Araujo 17 February 1995 (has links)
Devido à necessidade de caracterizar as armadilhas magneto-ópticas (AMO), as quais fornecem amostras densas de átomos frios, e de extrema importância o conhecimento dos valores das constantes mecânicas k e &#946 inerentes ao movimento harmônico super amortecido dos átomos nestas armadilhas. Neste trabalho, obtivemos estas constantes usando a técnica que aplica uma oscilação forçada aos átomos aprisionados através de um pequeno campo magnético oscilante adicional de forma a não perturbar o aprisionamento. Fizemos um estudo destas constantes como função de alguns parâmetros inerentes ao aprisionamento, como por exemplo: intensidade dos feixes laser, gradiente de campo magnético e dessintonia. A manipulação de átomos aprisionados, obtida através da observação de diversas estruturas espaciais dos mesmos, mostra um certo controle sobre estes átomos e a obtenção de valores para a temperatura dos átomos nestas estruturas, permite uma maior compreensão do mecanismo de aprisionamento. Nos detivemos então, na medida da temperatura dos átomos aprisionados em estrutura espacial do tipo anel além de propor um modelo teórico simples capaz de justificar os resultados obtidos. / In order to have precise characterization of magneto-optical traps (MOT), which are used to obtain a dense sample of cold atoms, it is important to measure the mechanical constants k and &#946 of the over-damped harmonic motion that rule the motion of the atoms inside the MOT. In this work, we obtain these constants by applying a small additional a.c. magnetic field that does not perturb the trap d.c. field but forces the trapped atoms to oscillate. We studied the variation of the constants by changing laser intensities, trapping field gradient and detuning. The manipulation of trapped atoms and the observation of several kinds of spatial structures allow one to have a better comprehension of the trapping mechanism. We measured the temperature of the atoms in the ring type structure and a simple theoretical model that explains the results is proposed.
20

Estudo dos mecanismos de fadiga e análise de desempenho em mola para válvula automotiva em regime de alto e ultra-alto ciclo. / Study on the fatigue mechanisms and performance analysis in automotive valve spring under high-and-ultra-high-cycle regime.

Edison Marcelo Serbino 05 March 2012 (has links)
Este trabalho apresenta um estudo dos mecanismos de fadiga em mola para válvula automotiva, realizado através da análise do comportamento mecânico correlacionado ao aspecto microestrutural. As amostras foram fabricadas em aço de alta resistência Si-Cr, submetidas a tratamentos térmicos convencionais (têmpera e revenimento) e não convencionais (austêmpera), obtendo um mesmo nível de dureza (aproximadamente 610 HV). Os corpos de prova foram submetidos a ensaios de bancada com diversos níveis de carregamentos, controlados através de variação da amplitude de tensão cisalhante. Esta variação promoveu diferentes regimes de fadiga, conhecidos como alto e ultra-alto ciclo, para maiores e menores níveis de amplitudes de tensões, respectivamente. O desempenho foi medido através do cálculo da vida total em fadiga, probabilidade de sobrevivência, além da verificação do relaxamento da força elástica e da tensão residual. As amostras foram caracterizadas através de métodos metalográficos, determinação da composição química, ensaios de dureza e resistência à tração, além de técnicas difratométricas de raios-X. As superfícies de fratura foram investigadas utilizando técnicas de microscopia eletrônica de varredura Os mecanismos de início e propagação das trincas, de ambas as amostras, foram semelhantes, apesar do tratamento térmico proposto de austêmpera produzir uma microestrutura mista, com predominância de bainita inferior, contendo regiões esparsas de austenita retida. A microestrutura bainítica, resultante da austêmpera, quando comparada com as amostras martensíticas, geradas pela têmpera e revenimento, propiciou um aumento da vida total em fadiga nos maiores níveis de amplitudes das tensões, tendendo à equalização com a diminuição desta amplitude, além de apresentarem um maior relaxamento elástico, gerando uma discreta diminuição de magnitude da tensão média. Por outro lado, não houve relaxamento das tensões residuais, em ambas as amostras, após uma quantidade significativa de ciclos, portanto este fenômeno não influenciou em sua vida total. / This paper presents a study on the valve spring fatigue mechanisms, carried out through analysis of mechanical behavior correlated to microstructural aspect. The samples were made of high strength steel Si-Cr, obtained by conventional (quenching and tempering) and unconventional (austempering) heat treatments, generating a single level of hardness (approximately 610 HV). The samples were subjected to bench test with various loading levels, controlled through shear stress amplitude fluctuation. This variation has promoted distinct fatigue regimes known as high and ultra-high cycle, for greater and smaller levels of stress amplitudes, respectively. The performance was measured by calculating the fatigue total life, survival probability, verification of the elastic force and residual stress relaxation. The samples were characterized by means of metallographic methods, chemical composition analysis, hardness/tensile strength testing and X-ray diffractometry techniques. The fracture surfaces were investigated using scanning electron microscopy techniques. The cracks initiation and propagation mechanisms were similar in both samples; despite the proposed austempering heat treatment produced a mixed microstructure with predominance of lower bainite, containing sparse regions of retained austenite. The bainitic microstructure, resulting of austempering, when compared with martensitic samples, generated by quenching and tempering, led to an increase in fatigue total life under higher levels of stress amplitudes, but tending to be the same as the stress amplitude deacresases and the number of cycles increases. On the other hand, there was no residual stresses relaxation in both samples, after a significant amount of cycles, so this phenomenon did not influence the total life.

Page generated in 0.0324 seconds