11 |
Characterization of collagen-mucopolysaccharide composite materials by electrochemical transduction.Palmer, Miles R January 1976 (has links)
Thesis (B.S.)--Massachusetts Institute of Technology, Dept. of Electrical Engineering and Computer Science; and, (B.S.)--Massachusetts Institute of Technology, Dept. of Chemistry, 1976. / Microfiche copy available in Archives and Engineering. / Bibliography: leaves 65-66. / B.S.
|
12 |
`In vitro` mucopolysaccharide metabolism of epithelial tissue cells / Ole Walter WiebkinWiebkin, Ole Walter January 1983 (has links)
Offprints of the author's articles inserted / Bibliography: leaves 230-265 / List of the author's publications: leaves 266-263 [i.e. 267] / 263 [i.e. 268] leaves : ill. (1 col.) ; 31 cm. / Title page, contents and abstract only. The complete thesis in print form is available from the University Library. / Thesis (Ph.D.)--University of Adelaide, Dept. of Dental Science, 1984
|
13 |
Improvement of the Digestibility of Sulfated Hyaluronans by Bovine Testicular HyaluronidaseLemnitzer, Katharina, Schiller, Jürgen, Becher, Jana, Möller, Stephanie, Schnabelrauch, Matthias 07 July 2014 (has links) (PDF)
Glycosaminoglycans (GAGs) such as hyaluronan (HA) and chondroitin sulfate (CS) are important, natural polysaccharides which occur in biological (connective) tissues and have various biotechnological and medical applications. Additionally, there is increasing evidence that chemically (over)sulfated GAGs possess promising properties and are useful as implant coatings. Unfortunately, a detailed characterization of these GAGs is challenging: although mass spectrometry (MS) is one of the most powerful tools to elucidate the structures of (poly)saccharides, MS is not applicable to high mass polysaccharides, but characteristic oligosaccharides are needed. These oligosaccharides are normally generated by enzymatic digestion. However, chemically modified (particularly sulfated) GAGs are extremely refractive to enzymatic digestion. This study focuses on the investigation of the digestibility of GAGs with different degrees of sulfation by bovine testicular hyaluronidase (BTH). It will be shown by using an adapted spectrophotometric assay that all investigated GAGs can be basically digested if the reaction conditions are carefully adjusted. However, the oligosaccharide yield correlates reciprocally with the number of sulfate residues per polymer repeating unit. Finally, matrix-laser desorption and ionization (MALDI) MS will be used to study the released oligosaccharides and their sulfation patterns.
|
14 |
Desenvolvimento de radiofarmaco para radiosinovectomia / Development of radiopharmaceutical for radiosinovectomyCOUTO, RENATA M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:47Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:54Z (GMT). No. of bitstreams: 0 / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
15 |
Desenvolvimento de radiofarmaco para radiosinovectomia / Development of radiopharmaceutical for radiosinovectomyCOUTO, RENATA M. 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:52:47Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T14:01:54Z (GMT). No. of bitstreams: 0 / Radiofármacos marcados com diferentes radionuclídeos são utilizados em aplicações diagnósticas e terapêuticas em Medicina Nuclear. Nos últimos anos houve um aumento no interesse pela terapia radionuclídica, com a introdução de novos radiofármacos aplicados para destruir especificamente determinada célula ou impedir sua proliferação indesejável. Uma modalidade terapêutica que emprega radiofármacos é a radiosinovectomia (RSV), na qual o radiofármaco é administrado na cavidade articular, sendo uma alternativa de tratamento existente para artropatia de várias etiologias e, em particular, àquelas associadas à artrite reumatóide e à hemofilia. O presente trabalho objetivou estudar a marcação de compostos com 90Y e 177Lu visando otimizar as condições de produção e controle de qualidade de pureza radioquímica, avaliar a estabilidade dos produtos gerados e realizar estudos preliminares de biodistribuição animal de radiofármacos com potencial para aplicação em radiosinovectomia. O estudo da produção do citrato coloidal de 90Y (Cit-90Y) foi baseado em procedimento de marcação utilizando solução de 90YCl3 (37 - 54 MBq) levada previamente à secura, seguida da adição de solução de nitrato de ítrio, e citrato de sódio em pH 7,0 com aquecimento à 37º C por 30 minutos. A produção de hidroxiapatita (HA) marcada com 90Y foi estudada tendo como base procedimento de marcação utilizando ácido cítrico monohidratado, nitrato de ítrio e a solução de 90YCl3 (37 - 370MBq). Incubou-se a mistura durante 30 minutos à temperatura ambiente e adicionou-se a hidroxiapatita em meio aquoso e incubou-se à temperatura ambiente durante 30 minutos sob forte agitação. Na produção de HA-177Lu, utilizou-se solução de 177LuCl3 (296 MBq), em presença de óxido de lutécio em meio de NaCl 0,9% pH 7, sob agitação contínua à temperatura ambiente durante 30 minutos. Diversos parâmetros de reação foram estudados para os três radiofármacos. O rendimento das marcações foi determinado por meio de centrifugação após lavagem das partículas com NaCl 0,9%. A análise de pureza radioquímica das marcações foi realizada por meio de cromatografia líquida ascendente utilizando diferentes sistemas cromatográficos. A análise do tamanho das partículas radiomarcadas foi realizada utilizando-se membranas filtrantes de poros de diferentes tamanhos. O comportamento biológico da HA-90Y e HA-177Lu foi estudado a partir da administração intra-articular (joelho) de 18,5 22,2 MBq /0,1 mL do respectivo radiofármaco. Foram adquiridas imagens cintilográficas em gama-câmara em diferentes tempos para determinar a retenção e o extravasamento da atividade da articulação. O método utilizado para produção do Cit-90Y resultou em baixo rendimento de marcação (cerca de 20%), com baixa porcentagem de atividade ligada às partículas com tamanho apropriado para aplicação em RSV. Apesar do baixo rendimento de marcação, as partículas radiomarcadas separadas por centrifugação apresentaram estabilidade relativa de cerca de 70% após 5 dias. A marcação da HA-90Y resultou em excelentes rendimentos de marcação (> 95%). A reação foi otimizada para aplicação rotineira com a redução do tempo de reação para 15 minutos e utilização de apenas um procedimento de centrifugação e lavagem. A marcação da HA com 177Lu resultou em excelente rendimento (> 95%), com otimização da % de ligação às partículas >12m, sendo que os melhores resultados foram obtidos nas marcações realizadas na ausência de óxido de lutécio. A HA marcada com 90Y e 177Lu apresentaram estabilidade in vitro, armazenado à temperatura ambiente dentro do período avaliado de 5 e 7 dias, respectivamente. Foram definidos sistemas cromatográficos em papel e em camada delgada para determinação da pureza radioquímica das preparações. Os estudos de biodistribuição realizados com a hidroxiapatita marcada com 90Y e 177Lu mostraram a estabilidade in vivo dos compostos, não tendo ocorrido extravasamento articular nem liberação do radionuclídeo livre para a circulação, confirmando o potencial de ambos para aplicação em radiosinovectomia. / Dissertacao (Mestrado) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
16 |
Improvement of the Digestibility of Sulfated Hyaluronans by Bovine Testicular Hyaluronidase: a UV Spectroscopic and Mass Spectrometric StudyLemnitzer, Katharina, Schiller, Jürgen, Becher, Jana, Möller, Stephanie, Schnabelrauch, Matthias January 2014 (has links)
Glycosaminoglycans (GAGs) such as hyaluronan (HA) and chondroitin sulfate (CS) are important, natural polysaccharides which occur in biological (connective) tissues and have various biotechnological and medical applications. Additionally, there is increasing evidence that chemically (over)sulfated GAGs possess promising properties and are useful as implant coatings. Unfortunately, a detailed characterization of these GAGs is challenging: although mass spectrometry (MS) is one of the most powerful tools to elucidate the structures of (poly)saccharides, MS is not applicable to high mass polysaccharides, but characteristic oligosaccharides are needed. These oligosaccharides are normally generated by enzymatic digestion. However, chemically modified (particularly sulfated) GAGs are extremely refractive to enzymatic digestion. This study focuses on the investigation of the digestibility of GAGs with different degrees of sulfation by bovine testicular hyaluronidase (BTH). It will be shown by using an adapted spectrophotometric assay that all investigated GAGs can be basically digested if the reaction conditions are carefully adjusted. However, the oligosaccharide yield correlates reciprocally with the number of sulfate residues per polymer repeating unit. Finally, matrix-laser desorption and ionization (MALDI) MS will be used to study the released oligosaccharides and their sulfation patterns.
|
17 |
Processos de obtenção e caracterização físico-química de quitinas e quitosanas extraídas dos rejeitos da indústria pesqueira da região de Cananéia – SP / Obtaining processes and physicochemical characterization of chitin and chitosan extracted of the fishing industry waste of Cananeia-SP regionFONSECA, ANA C.M. 11 November 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-11-11T09:14:09Z
No. of bitstreams: 0 / Made available in DSpace on 2016-11-11T09:14:09Z (GMT). No. of bitstreams: 0 / A quitina é o principal produto obtido do processamento das cascas de crustáceos. Esse biopolímero e o seu derivado, quitosana, têm despertado grande interesse comercial em virtude das possibilidades de aplicações que possuem. O gerenciamento desses resíduos e dos subprodutos gerados nas etapas no processo de obtenção pode ser considerado um modelo de biorrefinaria. A implementação de plantas para extração de quitina e quitosana é um desafio, uma vez que a demanda produtiva deve ser atendida sem causar danos ao meio ambiente. Uma grande variedade de quitosanas com diferentes propriedades físicoquímicas podem ser obtidas variando-se as condições de reação. Essas propriedades dependem da origem da matéria-prima, do seu grau médio de desacetilação, distribuição média dos grupos acetil ao longo da cadeia principal e da sua massa molecular média. Os fornecedores de quitosana comercial geralmente não mencionam a procedência da matéria-prima e pouca ou nenhuma informação é fornecida acerca do seu processamento. Sendo assim, as características e a reatividade do produto final podem variar gerando resultados não reprodutíveis. No presente estudo, foi utilizada a biomassa oriunda de rejeitos da indústria pesqueira de camarão da região de Cananéia SP. As amostras de - quitina foram obtidas por dois procedimentos diferentes: no primeiro, P1, as cascas de camarão após passar pelo pré-tratamento (lavagem, secagem e moagem) foram desproteinizadas para retirada das proteínas em hidróxido de sódio (NaOH) diluído nas concentrações 2%, 5% e 10% e desmineralizadas em ácido clorídrico (HCl) a 20% (v/v) para retirada dos carbonatos; no segundo procedimento, P2, essas etapas foram invertidas. A biomassa resultante foi desacetilada com hidróxido de sódio concentrado a 30%, 40% e 50% em tempos que variaram de 2 a 6 horas. As principais propriedades físico-químicas das amostras de quitosanas obtidas foram determinadas utilizando a espectroscopia na região do infravermelho com transformada de Fourier (FT-IR) para a determinação do grau médio de acetilação, GA, e a técnica de titulação ácido-base mensurada por condutimetria foi utilizada para comparar os resultados; a viscosimetria capilar para a determinação da massa molar média viscosimétrica, Mv , e a difração de raios X (DRX) para avaliar o grau médio de cristalinidade, X. Além disso, foram empregadas as técnicas de microscopia eletrônica de varredura (MEV) para análises morfológicas dos materiais obtidos e a espectrometria de fluorescência de raios X por dispersão de comprimento de onda (WDXRF) para análise química das quitosanas. O GA e o X das amostras diminuíram à medida em que o tratamento se tornou mais vigoroso, enquanto a Mv aumentou. O procedimento 2 foi o mais viável por eliminar a etapa de despigmentação, pois originou amostras com tonalidade mais clara e fáceis de pulverizar. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
18 |
Desenvolvimento de métodos para a geração e controle da emissão em lasers aleatórios e speckle / Generation and control of random lasers emission and speckleSILVA, DANILO M. da 11 November 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-11-11T11:16:35Z
No. of bitstreams: 0 / Made available in DSpace on 2016-11-11T11:16:35Z (GMT). No. of bitstreams: 0 / Neste trabalho serão apresentados novos métodos baseados na geração e controle de comprimento de onda em lasers aleatórios e lasers de diodo. Na primeira parte do trabalho será demonstrado um laser aleatório com realimentação localizada em filmes em biopolímeros dopado com corante. O filme é constituído por um ácido desoxirribonucleico e cloreto de cetiltrimetilamônio (DNA-CTMA) dopado com DCM. No dispositivo proposto, a realimentação óptica para o laser aleatório é dada por centros de dispersão posicionados aleatoriamente ao longo das bordas da área ativa. Os elementos de dispersão são nanopartículas de dióxido de titânio (TiO2) ou defeitos aleatórios na interface entre o polímero ativo e ar. Diferentes espectros de emissão são observados, dependendo da geometria da área excitada. Um único ressonador aleatório com dimensões de 2.6 x 0.65 mm2 foi fabricado com emissão aleatória com realimentação obtida pela excitação do dispositivo por completo. A segunda parte deste trabalho apresenta um novo método para a geração e manipulação de franjas de contorno por meio de interferometria speckle com comprimento de onda sintética, usando um único laser de diodo com cavidade externa. A cavidade externa permite sintonizar duas emissões simultaneamente, o que por sua vez muda o intervalo entre as franjas de contorno do interferômetro, além de aumentar a estabilidade do laser. Uma análise de Fourier é proposta como alternativa para medir o comprimento de onda sintético resultante das duas emissões do laser. / Tese (Doutorado em Tecnologia Nuclear) / IPEN/T / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
|
Page generated in 0.0266 seconds